Uttar Pradesh Jal Nigam-UPJN has published Tender For Invitation Of Rates For Supply Of Civil, Electrical, Sanitary, Other Materials And Piece Rated Works (Labour). Submission Date for this Tender is 23-03-2023. Building Work Tenders in farrukhabad Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

36877650
Tender For Invitation Of Rates For Supply Of Civil, Electrical, Sanitary, Other Materials And Piece Rated Works (Labour)
Open Tender
Indian
Uttar Pradesh
farrukhabad
23-03-2023

Tender Details

Tender For Invitation Of Rates For Supply Of Civil, Electrical, Sanitary, Other Materials And Piece Rated Works ( Labour ) - 1 Earth Work In Excavation In Trenches For Foundation Pipes, Cable Etc In Ordinary Sol ( Loam Clay Or Sand ) Inlcuding Lift Upto 1.5 Mt. Lead Upto 30Mt. And Dressing Of Sides And Rammings Of Bottom And Disposal Of Surplus Excavated Earth As Directed By The Engineer. 2 Upto 1.50 M To 3.00 M Deep 3 Upto 3.00 M To 4.50 M Deep 4 Upto 4.50 M To 6.00 M Deep 5 Filling Of Carted Earth 6 Laying In Position Cement Concrete Of Specifiedgrade Including The Cost Of Centring And Shuttering-All Work Upto Plinth Level. 7 In Cement Concrete 1:4:8 ( 1 Cement :4 Coarse Sand :8 Graded Stone Aggregate 40 Mm Nominal Size ) 8 In Cement Concrete 1:2:4 ( 1 Cement : 2 Course Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) 9 Coarse Sand ( Compacted ) Filling In Sides Of Foundation & Floor 10 Providing And Injecting Chemical Emulsion For Pre Constructional Antitermite Treatment And Creating A Chemical Barrier Under And Alround The Column Pits Wall Trenches Basement Excavation Top Surface If Plinth Filling Junction Of Wall And Floor, Along The The External Perimeter Of Binding Expansion Joints, Surrounding Of Pipes And Conduits Etc, Complete. ( Plinth Area Of The Building At Ground Floor Only Shall Be Measured As Per I.S.6313 ( Partii 1981 ) Alderine Emulsifiable Concentrate Or Any Other Approved Material Such As Heptrachlor Or Chlordane Will Be Used. The Rate Of Application Of Chemical Emulsion Shall Be As Follows : ( 1 ) Treatment For Masonary & Foundation 5 Liters Per Sqm. ( 2 ) Back Fill In Immediate Contact With Foundation 7.5 Liters / Sqm ( 3 ) Treatment Of Top Surface Of Plinth Filling 5 Liters / Sqm ( 4 ) Treatment Junction Of Wall And The Floor 7.5 Liters / Sqm ( 5 ) Treatment Of Soil Along External Perimeter Of Building 7.5 Liters / Sqm ( 6 ) Treatment Of Soil Under Apron Along External Perimter 5 Liters / Sqm. ( As Per ManufacturerS Standard Dilution ) 11 R.C.C. Work With Cement Approved Coarse Sand And 2 Cm. Guage Approved Stone Grit In The Proportion Of 1:1.5:3 In Lintels Of Doors And Windows Excluding Supply Of Reinforcement And Its Fixing And Binding The Same With 24 Bwg Binding Wire And Including Necessary Centering And Shuttering Etc.And Also Excluding Supply Of All Materials, And Including Labour And Tools And Plants Etc, Required For Proper Completion Of The Works. 12 Ground Floor 13 First Floor 14 Second Floor 15 As In Item No. 6 Above But For Slabs ( Using 1:1.5:3 Mix Concrete ) . 16 Ground Floor 17 First Floor 18 Second Floor 19 As In Item 6 But For Thelighterbeams I.E. Having Spans Upto 6 M. ( Using 1:1.5:3 Mix Concrete ) 20 Ground Floor 21 First Floor 22 Second Floor 23 As In Item 6 Abovebut Inr.C.C.Raft Foundation And Footingwithapproved Stone Ballast. ( Using1:1.5:3Mix Concrete ) 24 As In Item 6 Above But In R.C.C. Columns In 1:1.5:3 Having Strength Not Less Than M-20. 25 Ground Floor 26 First Floor 27 Second Floor 28 M-150 Brick Work In 1:6 ( One Cement And Six Coarse Sand Sand Of 2.25 Fineness Modulus ) Mortar Infoundation & Plinth Includinglabour And T & P Etc & Excluding Supply Of All Materials, Required For Proper Completion Of The Work. 29 M-150 Brick Work In 1:4 ( One Cement And Six Coarse Sand Sand Of 2.25 Fineness Modulus ) Mortar Infoundation & Plinth Includinglabour And T & P Etc & Excluding Supply Of All Materials, Required For Proper Completion Of The Work. 30 Laying Damp-Proof Course 40Mm Thick With Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand ( Zone-Iii ) : 4 Graded Stone Aggregate 12.5Mm Nominal Size ) 31 Applying A Coat Of Residual Petroleum Bitumen Of Grade Of Vg-10 Of Approved Quality Using 1.7 Kg Per Square Metre On Damp Proof Course After Cleaning The Surface With Brushes And Finally With A Piece Of Cloth Lightly Soaked In Kerosene Oil. 32 Same As In Item No. 11 Abovebutin Super-Structure Above Plinth Level Up To Floor Two Level ( Up To Two Storeys ) Includingnecessarycutting And Moulding Of Brick Work Asrequiredand Also Including Honeycombed Brick Work In Thickness Of Wall More Than 12Cms. ( 1:6 Cement : Coarse Sand ) 33 Ground Floor 34 First Floor 35 Second Floor 36 Same As In Item No. 14 But In1:4 Cement And Coarse Sand Mortar In Superstructure For Wall Thickness 12 Cms & Below Brick Work. 37 Ground Floor 38 First Floor 39 Second Floor 40 Mild Steel Or Iron In Plain Work Such As Reinforced Concrete Or Reinforced, Brick Work ( When Not Included In Over All Rates ) Wrought To Required Shape As Necessary Including Bending For Proper Completion Of The Work And Excluding Supply Of Steel Its Wastage Bend Hooks And Authorised Over Lapping Shall Be Measured Upto Floor Two Level. 41 Ground Floor 42 First Floor 43 Second Floor 44 15 Mm Cement Plaster On Rough Side Of Single Or Half Brick Wall Of Mix : 1:3 ( 1 Cement: 3 Coarse Sand ) 45 15 Mm Cement Plaster In Single Coat On Rough Side Of Single Or Halfbrick Wall For Interior Plastering Up To Floor Two Level Including Internal Rounded Angles Not Exceeding 80 Mm In Girth And Finshed Even And Smooth. ( 1 ) 1 Cement : 6 Fine Sand . 46 Ground Floor 47 First Floor 48 Second Floor 49 12Mm Cement Plaster In Single Coat On Fair Side Of Single Or Half Brick Wall For Exterior Plastering Up To Floor Two Level Including Internal Rounded Angles Chamfers, And / Or Roundedangles Not Exceeding 80Mm In Girth And Finished Even And Smooth No Extra For Mixing Any Additive. ( 1 ) 1 Cement : 6 Finesand. 50 Ground Floor 51 First Floor 52 Second Floor 53 Engraving Lines In The Plaster Of Outer Face Well Vertically & Horizontally To Display The Surface As Stone Facing As Directed By The Engineer-In-Charge Including Labpur, & T & P Etc. Required For Proper Completion Of The Work. 54 Ground Floor 55 First Floor 56 Second Floor 57 Add For Plaster Drip Course / Groove In Plastered Surface Or Moulding To R.C.C. Projections. 58 Laying 8 To 10 Mm Thick Ivory Or Light Shade Vitrified Tiles Of 600 X 600 Mm Size With All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Finishing With Cement Slurry & With Pigment Grouting & Polishing Complete Including Supply Of All Labour, T & P Etc. Excluding The Cost Of Materials Required For Proper Completion The Work. 59 Ground Floor 60 First Floor 61 Second Floor 62 Laying 8 To 10 Mm Thick Ivory Or Light Shade Vitrified Tiles Of 600 X 600 Mm Size With All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) Finishing With Cement Slurry & With Pigment Grouting & Polishing Complete Including Supply Of All Labour, T & P Etc. Excluding The Cost Of Materials Required For Proper Completion The Work. 63 Ground Floor 64 First Floor 65 Second Floor 66 Kota Stone Slab Flooring Over 20 Mm ( Average ) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab, Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) : 25 Mm Thick 67 Ground Floor 68 First Floor 69 Second Floor 70 Kota Stone Slabs 20 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm ( Average ) Thick Cement Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete. 71 Ground Floor 72 First Floor 73 Second Floor 74 Fixing Of 6 Mm Thick Approved China White / Coloured Glazed Tiles In Flooring Or Dado Laid With 1:3 Cement And Approved Coarse Sand Mortar Finished And Jointed With White Cement Slurry And Pigment And Polishing Complete Includinglabour And Tool Sand Plants & Excluding Supply Of All Materials, Etc. Required For Proper Completion Of The Work. 75 Ground Floor 76 First Floor 77 Second Floor 78 25 Mm Thick Cement Concrete Flooring 1:2:4 ( 1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 12.5Mm Nominal Size And Below ) By Laid Over Base Concrete Finished With Floating Coat Of Neat Cement ( Base Concrete To Be Paid Separately ) Including Fixing Of Glass Strips. ( Excluding Cost Of Glass Strips ) 79 Supply Of Flush Doors Commercial Qualityconforming To I.S.2202 Part I ( 1983 ) Including Fixing Of Wooden Cleats And Stoppers 80 35 Mm Thick 81 ( A ) Single Leaf 82 ( B ) Double Leaf 83 32 Mm Thick 84 ( A ) Single Leaf 85 Extra For Providing And Fixing Flush Doors With Decorative Veneering Instead Of Non Decorative Isi Marked Flush Door Shutters Conforming To Is: 2202 ( Part I ) 86 Fixing Of Flush / Pvc Doors Including Fixing Of Wooden / Pvc Cleats And Stoppers And Includingfixing And Adjustment Of Hinges, Bolts, Locks, Handle, Springs. Fittings To Be Supplied Departmentally. 87 Supply Of Factory Made Panel Pvc Door Shutter Consisting Of Frame Made Out Of M.S. Tubes Of 19 Gauge Thickness And Size Of 19 Mm X 19 Mm For Styles And 15X15 Mm For Top & Bottom Rails. M.S. Frame Shall Have A Coat Of Steel Primers Of Approved Make And Manufacture. M.S. Frame Covered With 5 Mm Thick Heat Moulded Pvc ‘C’ Channel Of Size 30 Mm Thickness, 70 Mm Width Out Of Which 50 Mm Shall Be Flat And 20 Mm Shall Be Tapered In 45 Degree Angle On Both Side Forming Styles And 5 Mm Thick, 95 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered In 45 Degree On The Inner Side To Form Top And Bottom Rail And 115 Mm Wide Pvc Sheet Out Of Which 75 Mm Shall Be Flat And 20 Mm Shall Be Tapered On Both Sides To Form Lock Rail. Top, Bottom And Lock Rails Shall Be Provided Both Side Of The Panel. 10 Mm ( 5 Mm X 2 ) Thick, 20 Mm Wide Cross Pvc Sheet Be Provided As Gap Insert For Top Rail & Bottom Rail, Paneling Of 5 Mm Thick Both Side Pvc Sheet To Be Fitted In The M.S. Frame Welded / Sealed To The Styles & Rails With 7 Mm ( 5 Mm+2 Mm ) Thick X 15 Mm Wide Pvc Sheet Beading On Inner Side, And Joined Together With Solvent Cement Adhesive. An Additional 5 Mm Thick Pvc Strip Of 20 Mm Width Is To Be Stuck On The Interior Side Of The ‘C’ Channel Using Pvc Solvent Adhesive Etc. Complete As Per Direction Of Engineer-In-Charge, Manufacturer’S Specification & Drawing. 30 Mm Thick Plain Pvc Door Shutters 88 Mild Steel Or Iron Work Of Small Sizes And Sections Such As Holding Down Bolts, Hold Fast Tierods, Gratings Etc. ( When Not Included In An Over All Rates ) Wrought To Required From Including Supply Of Steel And Its Wastage Including Cost Of Bolts, Nuts If Required For And Welding, Grinding And Making Holes As Required Completion Of Work Fabrication Of Holes Doors, Chaukhats Nosing. 89 M.S. Hold Fast For Doors And Windows 90 M.S. Grill 91 Z-Section Winodws ( Openable ) 92 M.S. Angle Door Chaukhat 40*40*5 93 Fixing Of Door, Windows / Ventilators Chaukhats In Position. 94 ( A ) Door Chaukhats 95 ( B ) Window Chaukhats 96 ( C ) Ventilator Chaukhats 97 Distempering ( Two Coat ) With Oil Bound Distemper Of Approved Brand And Manufacture & Of Required Shade On Undecorated Wall Surface To Give An Even Shade Over & Including A Priming Coat With Cement Primer Of Approved Brand & Manufacture Such As Berger, J&N, Shalimar, Asian Paints After Thoroughly Brushing The Surface Free From Mortar Droppings & Other Foreign Matters & Also Including Preparing The Surface Even With Plaster Of Paris Or Approved Synthetic Material & Sand Papered Smooth Including Cost Ofall Materials. ( Inside Walls ) 98 Ground Floor 99 First Floor 100 Second Floor 101 Finishing Walls With Two Coat Of Acrylic Smooth Exterior Paint Of Best Quality Including Supply Of All Materials Labour And Tool Sand Plants Etc. Required For Proper Completion Of The Work. 102 Ground Floor 103 First Floor 104 Second Floor 105 Finishing Wall With Water Proof Cement Paint Of Approved Make And Quality On New Wood With Two Coat To Give An Even Shade Including Supply Of All Materials, Labour, Tools And Plant Etc. Required For Proper Completion Of The Work. ( Two Coat ) 106 Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Supply Of All Materials, Labour, Tools And Plant Etc. Required For Proper Completion Of The Work. ( Two Coat ) 107 Distempering ( Two Coat ) With Oil Bound Distemper Of Approved Brand And Manufacture & Of Required Shade On Undecorated Wall Surface To Give An Even Shade Over & Including A Priming Coat With Cement Primer Of Approved Brand & Manufacture Such As Berger, J&N, Shalimar, Asian Paints After Thoroughly Brushing The Surface Free From Mortar Droppings & Other Foreign Matters & Also Including Preparing The Surface Even With Plaster Of Paris Or Approved Synthetic Material & Sand Papered Smooth Excludingcost Of All Materials. ( Ceiling ) 108 Providing & Applying White Cement Based Putty Of Average Thickness 1 Mm, Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 109 Supply Of 150 Mm Bright Finished Floor Stainless Steel Door Stopper With Rubber Cushion, Necessary Brass Screws Etc. To Suit Shutter Thickness Complete. 110 Supply Of Stainless Steel Sliding Door Bolts Isi Marked Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Nuts And Screws Etc Complete. ( A ) 250Mm X 16Mm . 111 Supply Of Stainless Steel Towerbolts ( Barrel Type ) With Necessary Screws Etc. Complete 112 ( A ) 300Mm X 10Mm 113 ( B ) 250 Mm X 10Mm 114 Supply Of Bright / Matt Finished Stainless Steel Handles Of Approved Quality & Make With Necessary Screws Etc All Complete. ( A ) 125 Mm 115 Providing And Laying Cement Based Water Proofing Treatment Including Preparation Of Surface As Required For Treatment Of Roofs, Balconies, Terraces Etc Consisting Of Following Operations: A ) Applying A Slurry Coat Of Neat Cement Using 2.75 Kg / Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is. 2645 And Approved By Engineer-In-Charge Over The Rcc Slab Including Adjoining Walls Upto 300 Mm Height Including Cleaning The Surface Before Treatment. B ) Laying Brick Bats With Mortar Using Broken Bricks / Brick Bats 25 Mm To 115 Mm Size With 50% Of Cement Mortar 1:5 ( 1 Cement : 5 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge Over 20 Mm Thick Layer Of Cement Mortar Of Mix 1:5 ( 1 Cement :5 Coarse Sand ) Admixed With Water Proofing Compound Conforming Tois : 2645 And Approved By Engineer-In-Charge To Required Slope And Treating Similarly The Adjoining Walls Upto 300 Mm Height Including Rounding Of Junctions Of Walls And Slabs C ) After Two Days Of Proper Curing Applying A Second Coat Of Cement Slurry Using 2.75 Kg / Sqm Of Cement Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge. D ) Finishing The Surface With 20 Mm Thick Jointless Cement Mortar Of Mix 1:4 ( 1 Cement :4 Coarse Sand ) Admixed With Water Proofing Compound Conforming To Is : 2645 And Approved By Engineer-In-Charge Including Laying Glass Fibre Cloth Of Approved Quality In Top Layer Of Plaster And Finally Finishing The Surface With Trowel With Neat Cement Slurry And Making Pattern Of 300X300 Mm Square 3 Mm Deep. E ) The Whole Terrace So Finished Shall Be Flooded With Water For A Minimum Period Of Two Weeks For Curing And For Final Test. All Above Operations To Be Done In Order And As Directed And Specified By The Engineer-In-Charge : With Average Thickness Of 120 Mm And Minimum Thickness At Khurra As 65 Mm. 116 Painting Or Vanishing Two Coat On Iron Work In Small Areas Or New Wood Work With One Coat Of Ready Mixed Priming Paint And One Coat Of Approved Superior Ready Mixed Paint Of Clear Synthetic Varnish Including Supply Of All Materials, Labour, T & P Etc. Required For Proper Completion The Work. Paint To Be Used Should Confirm To The I.S.I. No. 103 1950. 117 Same As Item Above But On New Wood Surface. 118 Fixing Panes Of Glass With Equal Or Equivalent I.S.I. Marked Quality Putty, Brads And Springs Including Supply Of All Materials, Labour Etc. Complete. 3.80 To 4.70 Mm Thick 119 Chequered Terrazo Tiles 22 Mm Thick With Graded Marble Chips Of Size Up To 6 Mm In Floors, Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Rubbing And Polishing & Excluding Supply Of All Materials Complete, On 20 Mm Thick Bed Of Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) : Light Shade Pigment Using White Cement. 120 Filling Of Light Cinder Filling Under Floor Of Toilets & Other Sunken Roofs. 121 Labour Charges For Wiring Points For Light With 1.5 Sqmm.Frlsh Pvc Insulated Single Core Copper Condutor Cable In Pvc Conduit Pipe Partly Concealed In Wall And Partly Laid In Slab Along With The Reinforcement Before Concreting, Complete With 1.5 Sqmm.Frlsh Pvc Insulated Multistrand Copper Conductor Cable As Earth Continuity Wire And Piano Type Switch Etc. Complete In All Respects. 122 Same As Item No. ( 1 ) But For Two Way Light Points. 123 Same As Item No. ( 1 ) But For Fanandlight Duty Exhaust Fan. 124 Same As Item No. ( 1 ) But For5amp Plug Point With Piano Type Switch And Socket Etc. 125 Addition When Modular Type Switches Etc Are Used In Place Of Piono Type Switches Etc. In Various Wiring Points. 126 Addition For Light / Fan Points With Modular Type Switchin Place Of Piono Type Switch. 127 Addition For Plugpointswith Modular Type Switchin Place Of Piono Type Switch. 128 Addition For Exhaust Fanpointswith Modular Type Switchin Place Of Piono Type Switch. 129 Wiring Of Submains With 2 Nos. 2.5 Sq.Mm & With 1 No. Earth Wire Of 1.5 Sq.Mm Fr Pvc Insulated 1100 V Grade Single Core Multistrand Copper Conductor Cable In 20 Mm Dia Heavy Duty ( 2Mm Thick ) Pvc Conduit Complete, Including Supply Of All Material, Labourand T&P Etc. Required For Proper Completion Of The Work As Directed By Engineer I / C. 130 Wiring Of Submain 2 Number 4 Sqmm . Frlsh Pvc Insulated 1100 V Grade Multistranded Single Core Copper Conductor Cable In Heavy Duty ( 2 Mm Thick ) 20Mm Dia Pvc Conduit Partly Concealed In Wall And Partly Laid In Slab Along With One Number 2.5 Sqmm Frlsh Pvc Insulated Multistranded Copper Conductor Cable As Earth Contunity Wire Etc. Complete In All Respects. 131 Wiring Of Submain 2 Number 6 Sqmm . Frlsh Pvc Insulated 1100 V Grade Multistranded Single Core Copper Conductor Cable In Heavy Duty ( 2 Mm Thick ) 20Mm Dia Pvc Conduit Partly Concealed In Wall And Partly Laid In Slab Along With One Number 4 Sqmm Frlsh Pvc Insulated Multistranded Copper Conductor Cable As Earth Contunity Wire Etc. Complete In All Respects. 132 Wiring Of Submain 4 Number 10 Sqmm . Frlsh Pvc Insulated 1100 V Grade Multistranded Single Core Copper Conductor Cable In Heavy Duty ( 2 Mm Thick ) 32Mm Dia Pvc Conduitalong With Two Numbers 6 Sqmm Frlsh Pvc Insulated Multistranded Copper Conductorcable As Earth Contunity Wire Etc. Complete In All Respects. 133 Wiring Of Submain 4 Number 16 Sqmm . Frlsh Pvc Insulated 1100 V Grade Multistranded Single Core Copper Conductor Cable In Heavy Duty ( 2 Mm Thick ) 40Mm Dia Pvc Conduitalong With Two Numbers 10 Sqmm Frlsh Pvc Insulated Multistranded Copper Conductor Cable As Earth Contunity Wire Etc. Complete In All Respects. 134 Wiring Of Submain 4 Number 25 Sqmm . Frlsh Pvc Insulated 1100 V Grade Multistranded Single Core Copper Conductor Cable In Heavy Duty ( 2 Mm Thick ) 50Mm Dia Pvc Conduitalong With Two Numbers 16 Sqmm Frlsh Pvc Insulated Multistranded Copper Conductor Cable As Earth Contunity Wire Etc. Complete In All Respects. 135 Fixing And Concealing Of20mm Dia.2Mm Thick Pvc Conduit Pipe With Isi Mark Embossed And With Pvc Acessories Confirming To Is No. 3419 For Drawing Wires Duly Sealed At Joints With Original Resin / Adhesive To Make The Complete Piping Rigid, Plastering With Cement Sand Mortar Finished To Level With Matching Colour Including Cost Of Material Labour And T & P Etc Required For Proper Completion Of Work ( Fortelephone ) 136 Erection And Testing Of Ceiling Fan And Regulator For Room Height Upto 3.5Mts. Including Supply Of 3Mm Thick G.I. Pipe 19Mm Dia Duly Painted, Complete In All Respects. 137 Erection And Testing Exhaust Fan On The Exhisting Hole With Suitable Size Of Rag Bolts Nuts And Washers Etc. Complete In All Respects. 138 Fixing Of Hexagonal / Round G.P. Fan Box Of Approved Make Made Up Of 1.0Mm Thick Isi Marked G.P. Sheet Spot Weeldeed Four To Eight Holes Of 25.4 Mm For Pipe Entry Of The Box. Holes Should Be Semi-Shuttered Type With 0.5Mm G.P. Sheet Made Upper & Lower Cover Duly Screewed Fitted With 300Mm Round Zink Coted M.S Bar X 12Mm & Brand Name Should Be Embossed.Fixing With Wiring Conduit Laid In The R.C.C Roof Before Concreting Alongwith Supply Of All Material, Labour, T&P Etc. Required For Proper Completion Of The Work. 139 Supply Of Ceiling Fan With Fan Motor Of A.C Permanent Insulation, Capacitor Rating Conforming Bee 5 Star Rating And Is:374 / 79 And Also Comply With Is: 1709 / 1984 With Latest Amendment. The Rated Voltage 220 / 240 Volts, 50Hz, 1-Ph Ac The Fan Assemble Should Consists Of Down Road Blades, Shackle Canopies Etc And With Double Ball Bearing System. Bee 5 Star Rated-1200Mm Sweep 140 Fixingofelectronic Fan Regulator ( Modular ) 120-280 V. Isimarked, On The Existing Switch Board Including Making Connetion, Required Material, Labour T / P Etc For Proper Completion Of Work To The Satisfaction Of Engineer In Charge Of Work. 141 Fixing Of Led Tube Light With Metal Heavy Dutybox Type Batten Light Fitting 2 X 22 Watt Suitable For Up To 2 X 22 Watt Led Polycarbonate Tube Light Complete Including Tube Etc Suitable For Both Surface & Surface Complete In All Respects. ( Cat: Aaa ) 142 Fixing Of Led Tube Light With Metal Heavy Dutybox Type Batten Light Fitting 1 X 22 Watt Suitable For Up To 1 X 22 Watt Led Polycarbonate Tube Light Complete Including Tube Etc Suitable For Both Surface & Surface Complete In All Respects. ( Cat: Aaa ) 143 Fixing Of Recess / Surface Mounting Round 10 To 15 Watt, Cut Out Min 125Mm, Height Min 40Mm, Led Down Lighter Having Powder Coated Die Cast Aluminium Housing With Heat Sink, Diffuser / Reflector And Driver Set, Suitable For 24Hr Continuous Operation, Complete In All Respect. ( Cat: Aaa ) 144 Fixing Of Single Led Light Wall Bracket On Matching M.D.F.E.G Board Base Etc. Complete In All Respect. ( Cat: Aaa ) 145 Fixing Of Water Tight Oblong 10 Watt Led Bulhead Luminaire With Driverr Set Confirming To Ip 65 And Above Protection Complete In All Respect. ( Cat: Aaa ) 146 Fixing Of Surface / Flush Mounting Distribution Boards With Additional Metal Door Withot Mcb Complete In All Respects. ( Cat A ) 147 4 Way Tpn 148 6 Way Tpn 149 8 Way Tpn 150 Fixing Of 6Amp To 32 Amp ( 10 Ka ) Sp Mcb In Existing Mcb, Db Complete With Connections As Required. ( Cat: A ) 151 Fixing And Making Connection Of Following Mcbs Complete In All Respects As Per Direction And Satisfaction Of Engineer-In-Charge. ( Cat: A ) 152 40 Amp. Fp Mcb ( Cat: A ) 153 63 Amp. Fp Mcb ( Cat: A ) 154 Fixing Of Surface / Flush Mounting V Tpn Distribution Boards With Additional Metal Door Withot Mcb Complete In All Respects. ( Cat A ) 4 Way V Tpn 155 Fixing And Making Connection Of Following Mccbs Complete In All Respects As Per Direction And Satisfaction Of Engineer-In-Charge. ( Cat: A ) 156 100 Amp. Fp Mccb ( Cat: A ) 157 125 Amp. Fp Mccb ( Cat: A ) 158 160 Amp. Fp Mccb ( Cat: A ) 159 Fixing And Making Connection Of Following Mcbs Complete In All Respects As Per Direction And Satisfaction Of Engineer-In-Charge. ( Cat: A ) 160 40 Amp. Tp Mcb ( Cat: A ) 161 63 Amp. Tp Mcb ( Cat: A ) 162 Fixing Of Power Plug With 15A / 250 V Flush Type Switch And 5 Pin 15 A / 250V Flush Type Universal Socket In Suitable M.S. Box Of 175Mmx100x50mm Size With Phenolic Laminated Bakellite Sheet Cover 3Mm Thick Fixed With Brass Machine Screws And Cup Washer. 163 Fixing Of Power Plug With 20A / 250 V Flush Type Switch And 5 Pin 20 A / 250V Flush Type Universal Socket In Suitable M.S. Box Including Supply Of All Material, Labor T&P Etc. Required For Proper Completion Of Work. 164 Fixing Of Single Pole Mcbs Blanking Plate Complete In All Respects. ( Cat: A ) 165 Fixing And Making Connection Of Following Mccbs Complete In All Respects As Per Direction And Satisfaction Of Engineer-In-Charge. 63 Amp. Fp Mccb 166 Supply And Burying Of 600Mm X 600 Mmx6mm G.I. Plate, Vertically For Earthing With Its Top Atleast 3 Mts. Below Ground Level Complete With 20Mm G.I.Pipe And Funnel For Watering And Two Earthing Leads Of No.8To10swg G.I.Wire In 15Mm Dia G.I. Pipe Upto Switch Board ( From Apron To Switch Board The Cost Of G.I. Pipe And G.I. Wire Will Be Extra ) 30Cm. Square C.I. Frame With Hinged Cover, Masonary Housing, Alternate Layers / Of Charcoal / Coke And Salt At Least 150Mm Thick Alround Etc. Complete In 167 Laying Of 25Mmx3mm G.I. Strip For Earthing Purpose As Required Complete In All Respects. 168 Fixing Of Two Number 8 Swg G.I. Wire In 15Mm Dia Gi Pipe For Earthing Purpose As Required Complete In All Respects. 169 Laying Of Aluminium Conducter, Pvc Insulated Armoured, Served, Sheeted Cable 1000 Bolts Grade At A Depth Of 750Mm Below Ground Level Over A Cushion Of 75Mm Thick Sand Alround And Protected With Burnt Bricks On Sides And Top On Surface, The 170 95 Sqmm3.5 Core 171 70 Sqmm3.5 Core 172 50 Sqmm3.5 Core 173 35 Sqmm3.5 Core 174 25 Sqmm3.5 Core 175 10 Sqmm4 Core 176 Fixing Of Brass Nickle Plated Compression Gland For Pvc Insulated & Armoured Served Sheathed, Underground Cable Including Rubber Ring Etc. Complete In All Respects. The Armouring Of The Cable Shall Be Properly Connected With The Earth As Per Dire 177 95 Sqmm3.5 Core 178 70 Sqmm3.5 Core 179 50 Sqmm3.5 Core 180 35 Sqmm3.5 Core 181 25 Sqmm3.5 Core 182 10 Sqmm4 Core 183 Fixing Of Palm / Pin Type Copper Tin Plated Cables Sockets ( Lugs ) To The Cable Leads, Insuslating With Tape And Making Of Connections Etc. Complete In All Respects As Per Direction Of Engineer-Incharge. 184 95 Sqmm 185 70 Sqmm 186 50 Sqmm 187 35 Sqmm 188 25 Sqmm 189 16 Sqmm 190 10 Sqmm 191 6 Sqmm 192 Fixing Ofmodular Boxes, Base & Cover Plate 193 Fixing Of Following Size / Modules, Gi Box Along With Modular Base& Cover Plate For Modular Switches In Recess Etc As Required. 1 Or 2 Module ( 75Mm X 75 Mm ) 194 Fixing Ofmodular Type Switch / Socket :- 195 Fixing Of Following Modular Switch / Socket On Theexisting Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc As Required. 196 Telephone Socket Outlet 197 Tv Antenna Socket Outlet 198 Bell Push 199 Fixing Of Call Bell / Buzzer Suitable Single Phase, 230 V Etc As Required. 200 Laying Oftelephone Wire Following Pair 0.5 Sqmm Fr Pvc Insulated Annealed Copper Conductor, Unarmoured Telephone Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 2 Pair 201 Drawing Of Co-Axial Tv Cable Rg-6 Grade, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 202 Drawing Telephone Wire Following Pair 0.5 Sqmm Fr Pvc Insulated Annealed Copper Conductor, Unarmoured Telephone Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 203 20 Pair 204 10 Pair 205 Fixing Of 10 Pair Junction Boxes For Floors And Building With Krone Connectors , With Connection And Punching Of Same 206 Fixing Of 20 Pair Junction Boxes For Floors And Building With Krone Connectors , With Connection And Punching Of Same 207 Fixing Of 50 Pair Junction Boxes For Floors And Building With Krone Connectors , With Connection And Punching Of Same 208 Laying Unplastisized Rigid Pvc Pipe Conforming To Is:13592 Type A Including Jointing , Cuttingand Making Good The Walls & Floors As Per Requirement. 150Mm 209 Supply Of Ac 230 / 250 Volts, 50 Hz Exhaust Fans Including Providing Nuts, Bolts, Mounting Frame And Other Accessories Including Connections Etc. Complete As Required 300Mm Sweep. 210 Fixing Of Energy Meter And Other Accessories Including Connections Etc. Complete As Required 3 Phase Meter 211 Erection Of Ac 230 / 250 Volts, 50 Hz Wall Fans Including Providing Nuts, Bolts, Mounting Frame And Other Accessories Including Connections Etc. Complete As Required450mm Sweep. 212 Supply Of Ac 230 / 250 Volts, 50 Hz Exhaust Fans Including Providing Nuts, Bolts, Mounting Frame And Other Accessories Including Connections Etc. Complete As Required450mm Sweep. ( At Labs ) 213 Fixing Of Wired Decorative Mirror Light On Suiatable For 9 Watt Led With Lamp Complete In All Respect. 214 Fixing Of Factory Wired Integral Led Flood Light Luminaires With Die Cast Aluminium Housing Built With Driver Set Suitable For 40 To 50 Watt Conforming To Ip 65 / 66 Protection Complete In All Respect. ( Cat-Aaa ) 215 Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A ) First Layer Of Slurry Of Cement @ 0.488 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. B ) Second Layer Of Slurry Of Cement@ 0.242 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg / Sqm.This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. 216 Fixing Of Stainless Steel ( Grade 304 ) Railing Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature ( Wherever Required ) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I / C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners , Stainless Steel Bolts Etc., Of Required Size, Excluding The Cost Of Materials On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge. 217 Providing And Fixing Of Expansion Joint System Related With Floor Location As Per Drawings And Direction Of Engineer-In-Charge. The Joints System Will Be Of Extruded Aluminum Base Members, Self Aligning / Self Centering Arrangement And Support Plates Etc. As Per Astm B221-02. The System Shall Be Such That It Provides Floor To Floor / Floor To Wall Expansion Control System For Various Vertical Localtion In Load Application Areas Thatccommodates Multi Directional Seismic Movement Without Stress To ItS Components. System Shall Consist Of Metal Profiles With A Universal Aluminum Base Member Designed To Accommodate Various Project Conditions And Finish Floor Treatments. The Cover Plate Shall Be Designed Of Width And Thickness Required To Satisfy Projects Movement And Loading Requirements And Secured To Base Members By Utilizing Manufacturer’S Pre-Engineered Self- Centering Arrangement That Freely Rotates / Moves In All Directions.The Self - Centering Arrangement Shall Exhibit Circular Sphere Ends That Lock And Slide Inside The Corresponding Aluminum Extrusion Cavity To Allow Freedom Of Movement And Flexure In All Directions Including Vertical Displacement. Provision Of Moisture Barrier Membrane In The Joint System To Have Watertight Joint Is Mandatory Requirement All As Per The Manufactures Design And As Approved By Engineer -In- Charge. ( Material Shall Confirm To Astm 6063 ) Floor Joint Of 100 Mm Gap 218 Providing And Fixing Of Expansion Joint System Of Approved Make And Manufactures For Various Roof Locations As Per Approved Drawings And Direction Of Engineer-In-Charge. The Joints Shall Be Of Extruded Aluminum Base Members With, Self Aligning And Self Centering Arragement Support Plates Asper Astm B221-02. The System Shall Be Such That It Provides Watertight Roof To Roof / Roof To Corner Joint Cover Expansion Control System That Is Capable Of Accommodating Multidirectional Seismic Movement Without Stress To Its Components. System Shall Consist Of Metal Profile That Incorporates A Universal Aluminum Base Member Designed To Accommodate Various Project Conditions And Roof Treatments. The Cover Plate Shall Be Designed Of Width And Thickness Required To Satisfy Movement 219 And Loading Requirements And Secured To Base Members By Utilizing Manufacturer’S Pre-Engineered Self-Centering Arrangement That Freely Rotates / Moves In All Directions. The Self Centering Arrangement Shall Exhibit Circular Sphere Ends That Lock And Slide Inside The Corresponding Aluminum Extrusion Cavity To Allow Freedom Of Movement And Flexure In All Directions Including Verticalisplacement. The Joint System Shall Resists Damage Or Deterioration From The Impact Of Falling Ice, Exposure To Uv, Airborne Contaminants And Occasional Foot Traffic From Maintenance Personnel. Provision Of Moisture Barrier Membrane In The Joint System To Have Water Tight Joint Is Mandatory Requirement. ( Material Shall Confirm To Astm 6063. ) Roof Joint Of 100 Mm Gap 220 Providing And Fixing Of Expansion Joint Systemelated With Wall Joint ( Internal / External ) Location As Per Drawings And Direction Of Engineer-In- Charge. The Joints Shall Be Of Extruded Aluminum Base Members, Self Aligning / Centering Arrangement And Support Plates As Per Astm B221- 02. The Material Shall Be Such That It Provides An Expansion Joints System Suitable For Vertical Wall To Wall / Wall To Corner Application, Both New And Existing Construction In Office Buildings & Complexes With No Slipping Down Tendency Amongst The Components Of The Joint System. The Joint System Shall Utilize Light Weight Aluminum Profiles Exhibiting Minimalexposed Aluminum Surfaces Mechanically Snap Locking The Multicellular To Facilitate Movement. ( Material Shall Confirm To Astm 6063 ) .Wall Joint Of 100 Mm Gap 221 Fixing In Position Stainless Steel Grade 304 Plate-1.0 Mm Thick As Per Design For Expansion Joints. 200 Mm Wide. 222 Granite Stone Slab 18 Mm Thick Mirror Polished Quarter Rounded With Anti Skid Lines In Treads Of Staircase Full Length Flooring Over 20 Mm ( Average ) Thick Base Laid Over And Jointed With Cement Slurry Mixed With Pigment To Match The Shade Of Including Rubbing & Polishing Complete With Base Of Cement Mottar 1:4 ( 1 Cement : 4 Coarse Snad ) Etc. Complete Excluding The Cost Of Materials. 223 Ground Floor 224 First Floor 225 Second Floor 226 Fixing In Position Collapsible Steel Shutters With Vertical Channels 20X10x2 Mm And Braced With Flat Iron Diagonals 20X5 Mm Size, With Top And Bottom Rail Of T-Iron 40X40x6 Mm, With 40 Mm Dia Steel Pulleys, Complete With Bolts, Nuts, Ocking Arrangement, Stoppers, Handles, Including Applying A Priming Coat Of Approved Steel Primer & Excluding The Cost Of Materials. 227 Fixing Rolling Shutters Of Approved Make Of 80 × 125 Mm ( 3 × 18 Gauge ) Cold Rolled Ml Lath Inter Lockedthrough Their Eintire Length And Joined Together At The End By Locks And Mountedon Specially Designed Pipe Shaft With Brackets And Wall Bearing & Excluding The Cost Of Materials. 228 40Mm Thick Cement Concrete Flooring 1:2:4 ( 1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size And Below ) By Laid Over Base Concrete Finished With Floating Coat Of Neat Cement ( Base Concrete To Be Paid Separately ) Including Fixing Of Glass Strips. ( Excluding Cost Of Glass Strips ) 229 Fixing Glass Strips In Joints Of Floors And Skirting Or Dado Add The Item Of Laying Floors Flush With Floor Level Including Supply Of All Materials, Labour, T & P Etc. Required For Proper Completion The Work. ( A ) 37 Mm Wide And 3.15 Mm Thick 230 52 Mm Thick Cement Concrete Flooring With Concrete Hardener Topping, Under Layer 40 Mm Thick Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) And Top Layer 12 Mm Thick Cement Hardener Consisting Of Mix 1:2 ( 1 Cement Hardener Mix : 2 Graded Stone Aggregate 6 Mm Nominal Size ) By Volume, Hardening Compound Mixed @ 2 Litre Per 50 Kg Of Cement Or As Per ManufacturerS Specifications.But Excluding The Cost Of Materials Etc. Complete. 231 Supply Of 80Mm Thick Rubber Moulded Cement Concrete Interlocking Pavers Block. The Compressive Strength Of Concrete Pavers Blocks Shall Not Be Less Than 30Mpa & 4.5Kg / No. 232 Providing And Laying Of 80Mm Thick Rubber Moulded Cement Concrete Interlocking Pavers Block. The Compressive Strength Of Concrete Pavers Blocks Shall Not Be Less Than 30Mpa & 4.5Kg / No. 233 Fixing Of Angle Iron Frame 40X40x6 Mm In Position. 234 Fencing With R.C.C. Post Placed At Required Distance, Embedded In Cement Concrete Blocks, Every 15Th Post, Last But One End Post And Corner Post Shall Be Strutted On Both Sides And End Post One Side Only, Provided With Horizontal Lines And Two Diagonals Of Barbed Wire Weighing 9.38 Kg Per 100 Metres ( Minimum ) , Between The Two Posts Fitted And Fixed With G.I. Staples On Wooden Plugs Or G.I. Binding Wire Tied To 6 Mm Bar Nibs Fixed While Casting The Post ( Cost Of R.C.C. Posts, Struts, G.I. Barbed Wire, Earth Work And Concrete To Be Paid For Separately ) 235 Mild Steel Or Iron Work In Heavy Sizes Such As Trusses Built Up Gates, Door Frames, Record Racks, Roof Work Gates Etc. Wrought To Required From Including Supply Of Steel And Its Wastage Including Cost Of Bolts, Nuts If Required For And Welding, Grinding And Making Holes As Required Completion Of Work Fabrication Of Holes Doors, Chaukhats Nosing. 236 Providing And Fixing Fly Proof Galvanized M.S. Wire Gauge To Windows And Clerestory Windows Using Wire Gauge With Average Width Of Aperture 1.4 Mm In Both Directions With Wire Of Dia 0.63 Mm All Complete. With 2Nd Class Teak Wood Beading 62X19 Mm. 237 Providing And Fixing Wire Gauge Shutters Using Stainless Steel Grade 304 Wire Gauge With Wire Of Dia 0.5 Mm And Average Width Of Aperture 1.4 Mm In Both Directions For Doors, Windows And Clerestory Windows With Necessary Screws : 35 Mm Thick Shutters With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size 238 Providing And Fixing Isi Marked Flush Door Shutters Conforming To Is : 2202 ( Part I ) Decorative Type, Core Of Block Board Construction With Frame Of 1St Class Hard Wood And Well Matched Teak 3 Ply Veneering With Vertical Grains Or Cross Bands And Face Veneers On Both Faces Of Shutters. Extra For Providing And Fixing Flush Doors With Decorative Veneering Instead Of Non Decorative Isi Marked Flush Door Shutters Conforming To Is: 2202 ( Part I ) On One Side Only 239 P / F Curtain Rods Of 1.25Mm Thick Chromium Plated Brass Plate, With Two Chromium Plated Brass Brackets Fixed With C.P. Brass Screws And Wooden Plugs Etc. Wherever Necessary Complete ( A ) 25 Mm Dia. 240 Fixing Of G.I. Pipe ( 80 Mm Dia ) As Per Design & Drawing As Per Drection Of Eic 241 Fabrication Of Angle Iron Door Chaukhat Of 40*40*6 Mm 242 Supply Of Concertina Coil Fencing With Punched Tape Concertina Coil 600 Mm Dia 10 Metre Openable Length ( Total Length 90 M ) , Having 50 Nos Rounds Per 6 Metrelength, Upto 3 M Height Of Wall With Existing Angle Iron ‘Y’ Shaped Placed 2.4M Or 3.00 M Apart And With 9 Horizontal R.B.T. Reinforced Barbed Wire, Stud Tied With G.I. Staples And G.I. Clips To Retain Horizontal, Including Necessary Bolts Or G.I. Barbed Wire Tied To Angle Iron, All Complete As Per Direction Of Engineer-In-Charge, With Reinforced Barbed Tape ( R.B.T. ) / Spring Core ( 2.5Mm Thick ) Wire Of High Tensile Strength Of 165 Kg / Sq.Mm With Tape ( 0.52 Mm Thick ) And Weight 43.478 Gm / Metre. 243 Fixing Of Concertina Coil Fencing With Punched Tape Concertina Coil 600 Mm Dia 10 Metre Openable Length ( Total Length 90 M ) , Having 50 Nos Rounds Per 6 Metrelength, Upto 3 M Height Of Wall With Existing Angle Iron ‘Y’ Shaped Placed 2.4M Or 3.00 M Apart And With 9 Horizontal R.B.T. Reinforced Barbed Wire, Stud Tied With G.I. Staples And G.I. Clips To Retain Horizontal, Including Necessary Bolts Or G.I. Barbed Wire Tied To Angle Iron, All Complete As Per Direction Of Engineer-In-Charge, With Reinforced Barbed Tape ( R.B.T. ) / Spring Core ( 2.5Mm Thick ) Wire Of High Tensile Strength Of 165 Kg / Sq.Mm With Tape ( 0.52 Mm Thick ) And Weight 43.478 Gm / Metre ( Cost Of Materialsshall Be Paid Separately ) 244 Supply Of M.S. Foot Rest As Per Standard Design With 20X20mm Sq Bars. 245 Fixing Of M.S. Foot Rest Including Fixing With 20X20x10 Cm. Cement Concrete Block 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Gradded Aggregate Of Nominal Size 20Mm ) As Per Standard Design With 20X20mm Sq Bars. 246 Supply Ofc.I. Tee At The Inlet And Outlet Of Septic Tank. 247 Fixing C.I. Tee At The Inlet And Outlet Of Septic Tank. 248 Supply Of 75Mm Dia Vent Pipes. 249 Fixing Of 75Mm Dia Vent Pipes. 250 Supply Of 75Mm Dia Cast Iron Terminal Guard. 251 Fixing Of 75Mm Dia Cast Iron Terminal Guard. 252 Supply Ofprecast Rcc Manhole Cover And Frame Of Required Shape And Approved Quality. 253 M.D. -10- Circular Shape 500Mm Internal Diameter 254 M.D. -2.5- Circular Shape 450Mm Internal Diameter 255 Fixing In Position Precast Rcc Manhole Cover And Frame Of Required Shape And Approved Quality. 256 M.D. -10- Circular Shape 500Mm Internal Diameter 257 M.D. -2.5- Circular Shape 450Mm Internal Diameter 258 Excavating Trenches In All Kinds Ofsoil Of Required Width For Pipes. Including Excavation For Sockets And Dressing Of Sides, Ramming Of Bottoms, Including Getting Out The Excavated Soil & Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth Including Consolidating Each Deposited Layer By Ramming, Watering, Etc & Disposing Of Surplus Excavated Soil As Directed Within A Lead Of 50M. 259 Up To 1.50 M Depth 260 Pipes 80 Mm To 300 Mmdiameter 261 1.50 M To 3.00 M Depth 262 Pipes 80 Mm To 300 Mmdiameter 263 Opentimbering In Trenches Including Shuttering And Shoring Complete. ( Measurement To Be Taken Of The Face Area Timbered ) 264 Depth Not Exceeding 1.5 Meter 265 Depth 1.5 To3.00Meter 266 Supply Of Non Pressurenp 2 Class ( Light Duty ) Rcc Pipe With Collars Etc. Complete. 267 150 Mm.Dia. Rccpipes 268 250 Mm.Dia. Rccpipes 269 100 Mm Dia Rcc Pipes 270 Laying Of Nonpressurenp 2 Class ( Light Duty ) Rcc Pipe With Collars Jointed Withstiffmixtureofcement Mortar In The Proportion Of 1:2 ( 1Cement : 2 Finesand ) Includingtestingof Joints Etc. Complete. 271 150 Mm.Dia. Rccpipes 272 250 Mm.Dia. Rccpipes 273 100 Mm Dia Rcc Pipes 274 Laying Cement Concrete 1:5:10 ( 1 Cement: 5 Coarse Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) Upto The Haunches Of Pipes Including Bed Concrete As Per Standard Design 275 150 Mm.Dia. Rccpipes 276 250 Mm.Dia. Rccpipes 277 100 Mm Dia Rcc Pipes 278 Constructing Brick Masonry Manhole In Cement Mortar 1:4 ( 1 Cement :4 Coarse Sand ) Rcc Top Slab With 1:2:4 Mix ( 1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nominal Size ) , Foundation Concrete 1:4:8 Mix ( 1 Cement :4 Coarse Sand :8 Graded Stone Aggregate 40Mm Nominal Size ) Inside Plastering 12Mm Thick With Cement Mortar 1:3 ( 1 Cement :3 Coarse Sand ) Finished With Floating Coat Fo Neat Cement And Making Channels In Cement Concrete 1:2:4 ( 1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20Mm Nminal Size ) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design. 279 Inside Size 90X80cms And 45Cms Deep Including Ci Cover With Frame ( Light Duty ) 455X610mm Internal Diamensions Total Weight Of Cover And Frame To Be Not Less Than 38 Kg ( Weight Of Cover 23 Kg And Weight Of Frame 15Kg ) . 280 Extra For Depth For Manholes: 281 Inside Size 90X120cms And 90Cms Deep Including Ci Cover With Frame ( Medium Duty ) 455X610mm Internal Diamensions Total Weight Of Cover And Frame To Be Not Less Than 116 Kg ( Weight Of Cover 58 Kg And Weight Of Frame 58Kg ) . 282 Extra For Depth For Manholes: 283 Supply Of Orange Colour Safety Footrests Of Minimum 6 Mm Thick Plastic Encapsulated As Per Is:10910 On 12 Mm Dia Steel Bar Conforming To Is:1786 Having Minimum Cross Section As 23 Mm X 25 Mm And Over All Minimum Length 263 Mm And Width As 165 Mm With Minimum 112 Mm Space Between Protruded Legs Having 2 Mm Thread On Top Surface By Ribbing Or Chequering Besides Necessary And Adequate Anchoring Projections On Tail Length On 138 Mm As Per Standard Drawing And Suitable To With Stand The Bend Test And Chemical Resistance Test As Per Specifications And Having ManufactureS Permanent Identification Mark To Be Visible Even After Fixing. 284 Fixing Of Orange Colour Safety Footrests Of Minimum 6 Mm Thick Plastic Encapsulated As Per Is:10910 On 12 Mm Dia Steel Bar Conforming To Is:1786 Having Minimum Cross Section As 23 Mm X 25 Mm And Over All Minimum Length 263 Mm And Width As 165 Mm With Minimum 112 Mm Space Between Protruded Legs Having 2 Mm Thread On Top Surface By Ribbing Or Chequering Besides Necessary And Adequate Anchoring Projections On Tail Length On 138 Mm As Per Standard Drawing And Suitable To With Stand The Bend Test And Chemical Resistance Test As Per Specifications And Having ManufactureS Permanent Identification Mark To Be Visible Even After Fixing, Including Fixing In Manholes With 30X20x15 Cm Cement Concrete Block 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) Complete As Per Design. 285 Supply Of Double Flanged ( Screwed / Welded ) Centrifugally ( Spun ) Ductile Iron Pipes Of Class K-9 Conforming To Is 8329 100Mm Dia Ductile Iron Double Flanged 286 Fixing & Laying Double Flanged ( Screwed / Welded ) Centrifugally ( Spun ) Ductile Iron Pipes Of Class K-9 Conforming To Is 8329 100Mm Dia Ductile Iron Double Flanged 287 Supply Of Ci Specials Such As Bends, Reducers, Collars Etc. Including Cartage, Loading, Unloading, Taxes, Excise Etc. Complete. 288 Fixing Of Ci Specials Such As Bends, Reducers, Collars Etc. Including Cartage, Loading, Unloading, Taxes, Excise Etc. Complete. 289 Supply Of Push-On-Joints To Centrifugally ( Spun ) Cast Iron Pipes Or Ductile Iron Pipes Including Testing Of Joints And Including The Cost Of Rubber Gasket : 100Mm Dia Pipes 290 Fixing Of Push-On-Joints To Centrifugally ( Spun ) Cast Iron Pipes Or Ductile Iron Pipes Including Testing Of Joints And Including The Cost Of Rubber Gasket : 100Mm Dia Pipes 291 Supply Ofc.I. Sluice Valves ( With Cap ) Complete With Bolts, Nuts, Rubber Insertions Etc. ( The Tail Pieces If Required Will Be Paid Separately ) : 100Mm Diameter 292 Fixing Of C.I. Sluice Valves ( With Cap ) Complete With Bolts, Nuts, Rubber Insertions Etc. ( The Tail Pieces If Required Will Be Paid Separately ) : 100Mm Diameter 293 Supply Of C.I. Double Acting Air Valve Of Approved Quality With Bolts, Nuts, Rubber Insertions Etc. Complete ( The Tail Pieces, Tapers Etc. If Required Will Be Paid Separately. A ) 50Mm Dia 294 Fixing Of C.I. Double Acting Air Valve Of Approved Quality With Bolts, Nuts, Rubber Insertions Etc. Complete ( The Tail Pieces, Tapers Etc. If Required Will Be Paidsaperately 50Mm Dia 295 Supply Of G.I. Pipes ( Medium ) Complete With G.I. Fittings 296 80Mm Nominal Bore. 297 65Mm Nominal Bore. 298 50Mm Nominal Bore. 299 40Mm Nominal Bore. 300 32Mm Nominal Bore. 301 25Mm Nominal Bore. 302 20Mm Nominal Bore. 303 15Mm Nominal Bore. 304 Laying, Jointing, Testing & Commisioning Ofg.I. Pipes Complete With G.I. Fittings Includingtenching And Refilling Etc. ( External Work ) 305 80Mm Nominal Bore. 306 65Mm Nominal Bore. 307 50Mm Nominal Bore. 308 40Mm Nominal Bore. 309 32Mm Nominal Bore. 310 25Mm Nominal Bore. 311 20Mm Nominal Bore. 312 15Mm Nominal Bore. 313 Supplying Of Specials For Pressure Pipe. 314 Fixing Of Specials For Pressure Pipe. 315 Supply Ofgate Valve ( With Cap Complete With Bolts, Nuts, Rubber Insertion Etc. 316 80Mm Nominal Bore. 317 65Mm Nominal Bore. 318 50Mm Nominal Bore. 319 40Mm Nominal Bore. 320 32Mm Nominal Bore. 321 25Mm Nominal Bore. 322 Fixing Of Gate Valve ( With Cap Complete With Bolts, Nuts, Rubber Insertion Etc. 323 80Mm Nominal Bore. 324 65Mm Nominal Bore. 325 50Mm Nominal Bore. 326 40Mm Nominal Bore. 327 32Mm Nominal Bore. 328 25Mm Nominal Bore. 329 Constructing Masonry Chamber 90X90x100 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Sluice Valve, With C.I. Surface Box 100Mm, Top Diameter, 160 Mm Bottom Diameter And 180Mm Deep ( Inside ) With Chained Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement :5 Fine Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12 Mm Thick Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 330 Constructing Brick Masonry Chamber 600 X 600X750mm Insidewithf.P.S. Brickwork In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Sluice Valve / Air Valve, With C. I. Surface Box 100 Mmtop Diameter, 160 Mm Bottom Diameter And 180Mm Deep ( Inside ) With Chained Lid And Rcc Top Slabwith 1 : 2 : 4 Mix ( 1 Cement : 2 Coarsesand : 4 Gradestone Aggregate 20 Mm Nominal Size ) ; Necessary Excavation, Foundationconcrete 1:5:10 ( 1 Cement : 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plasteringwithcement Mortar 1 : 3 ( 1 Cement : 3 Coarsesand ) 12Mmthick Finished With A Floatingcoatofneat Cementcomplete As Per Standarddesign 331 Supply Offire Brigade Inlet With 63 Mm Dia Instantaneous Inlet Complete With All Necessary Fittings And Ms Enclosure With Glass Door Made Of 18 / 16 Swg Sheet. 4 Way 332 Fixing, Installation, Testing & Commissioning Offire Brigade Inlet With 63 Mm Dia Instantaneous Inlet Complete With All Necessary Fittings And Ms Enclosure With Glass Door Made Of 18 / 16 Swg Sheet. 4 Way 333 Supply Of Sluice Valve Complete With Flanges, Gasket, Nut Bolts 150 Mm 334 Fixing, Installation, Testing & Commissioning Of Sluice Valve Complete With Flanges, Gasket, Nut Bolts 150 Mm 335 Supply Of Nrv Complete With Flanges, Gasket And Nut Bolts. 150 Mm 336 Fixing, Installation, Testing & Commissioning Of Nrv Complete With Flanges, Gasket And Nut Bolts. 150 Mm 337 Supply Of Ms Pipes Conforming To Is:1239 ( Medium- B Class ) Including All Fittings Like Anchor Fasteners, Brick Masonry Supports, Couplings, Bends, Elbows, Tees And Flanges Etc. Welded Or Screwed Joints As Required ( For Riser ) 338 150 Mm Dia 339 100Mm Dia 340 Fixing Of Ms Pipes Conforming To Is:1239 ( Medium- B Class ) Including All Fittings Like Anchor Fasteners, Brick Masonry Supports, Couplings, Bends, Elbows, Tees And Flanges Etc. Welded Or Screwed Joints As Required, Cutting Holes And Chases In Brick Or Rcc Walls And Making Good Complete. ( For Riser ) 341 150 Mm Dia 342 100Mm Dia 343 Supply Of Manual Swing Type First Aid Fire Hose Reel Conforming To Is: 444 Complete With All Other Necessary Fixing Accessories. 344 Fixing, Installation, Testing And Commissioning Of Manual Swing Type First Aid Fire Hose Reel Conforming To Is: 444 Complete With All Other Necessary Fixing Accessories. 345 Supply Of Fire Man Axe. 346 Fixing Of Fire Man Axe. 347 Supply Of Singal Headed Hydrant Landing Valve Comprising Of 80 Mm Dia Flanged Bend 63 Mm Dia, With Cap And Chain Conforming To Is:5290 ( Make : Newage / Minimax / Safex / Firex ) 348 Fixing, Installation, Testing & Commissioning Of Singal Headed Hydrant Landing Valve Comprising Of 80 Mm Dia Flanged Bend 63 Mm Dia, With Cap And Chain Conforming To Is:5290 ( Make : Newage / Minimax / Safex / Firex ) 349 Supply Of Rrl Hose Pipe 63 Mm Dia × 15 Mtr. Long With Gm Coupling Conforming To Is : 636 ( Make - Newage / Jayshree / Crc ) 350 Fixing, Installation, Testing & Commissioning Of Rrl Hose Pipe 63 Mm Dia × 15 Mtr. Long With Gm Coupling Conforming To Is : 636 ( Make - Newage / Jayshree / Crc ) 351 Supply Of Short Branch Pipe As Per Is:903 ( Make : Newage / Safex / Firex ) 352 Fixing, Installation, Testing & Commissioning Of Short Branch Pipe As Per Is:903 ( Make : Newage / Safex / Firex ) 353 Supply Of Butterfly Valve Complete With Flanges, Gasket, Nut Bolts 100 Mm 354 Fixing, Installation, Testing & Commissioning Of Butterfly Valve Complete With Flanges, Gasket, Nut Bolts 100 Mm 355 Supply Of Hose Cabinet Box Of 18 Swg M.S.Sheet With Glass To Accommodate Hose Reel Drum With Ruber Pipe With Nozzle. 2 Nos. Rrl Hose And 1 No. Branch Pipe With Nozzle 356 Fixing, Installation, Testing & Commissioning Of Hose Cabinet Box Of 18 Swg M.S.Sheet With Glass To Accommodate Hose Reel Drum With Ruber Pipe With Nozzle. 2 Nos. Rrl Hose And 1 No. Branch Pipe With Nozzle 357 Supply Of Air Cushion Tank ( 2000X1000 ) Mm. 358 Fixing, Installation, Testing & Commissioning Of Air Cushion Tank ( 2000X1000 ) Mm. 359 Supply Of Air Release Valve. 360 Fixing, Installation, Testing & Commissioning Of Air Release Valve. 361 Supply Of Nrv Complete With Flanges, Gasket And Nut Bolts. 100 Mm 362 Fixing, Installation, Testing & Commissioning Of Nrv Complete With Flanges, Gasket And Nut Bolts. 363 Supply Of Pressure Gauge With Gauge Cock 364 Fixing, Installation, Testing & Commissioning Of Pressure Gauge With Gauge Cock 365 Supply Of Electrical Motor Driven Fire Pump Suitable For Automatic Operation Consisting Of Following : ( Terrace Pump ) ( Make : Kirloskar / Mather+Platt ) ( A ) Horozontally Mounted, Split Casing, Centrifugal Fire Pump Complete For Delivery Of Under Mentioned Discharge Against Desired Mentioned Head So As To Ensure A Minimum Pressure Of 30 Meter At The Highest And Farthest Outlet At The Specified Flow Cmplete With Necessary Strainers, Pressure Gauge Including Bypass Arrangement For Periodic Testing Of The Working Of The Pumpset With Required Length And Size Of Medium Class Gi Pipe And Control Valves For Proper Completion Of Work.The Pump Shall Be Capable Of Giving 150% Of Rated Discharge At Head Not Less Than 65% Of Rated Head.The Pump Shall Be Provided With Mechanical Seals. The Impeller Shall Be Enclosed Type And Accurately Blanced Dynamically.The Pump Casing Shall Be Of Cast Iron, Impeller Shall Be Of Bronze And Shaft Shall Be Of Stainless Steel. ( B ) Squirrel Cage, Tefc Induction Motor Suitable For 415 V, 3 Phase Having Ip 55 Protection And Class B Insulation For The Above Pump And Flexible Coupling With The Pump.The Motor Shall B Rated For Continuous Duty And Shall Have Hp Rating Necessary To Drive Th Pump At 150% Of ItS Rated Discharge At 65% Of Rated Head. © Common Bed Plate Of Fabricated Mild Steel Channel Or Cast Iron Type. ( D ) Suitable Cement Concrete Pump Foundation And Vibration Clamping Arrangement As Required With Foundation Bolts, Anti Vibration Pads, Washers Etc. ( E ) Pressure Switch For Automatic Operation Of Motor Including Necessary Wiring Upto Control Panel. ( F ) Electrical Control Panel With Starter, 3 Pole Motor Protection Category Current Limiting Type Mccb, Indicating Light, Ammeter, Voltmeter, Selector Switches, CtS Protective Fuses, Single Phasing Protection, Dry Suction Cut Off Etc As Requrd As Per Standard Details.Discharge :450 Liter Per Minute Head : 35 Meter 366 Installation, Testing And Commisioning Of Electrical Motor Driven Fire Pump Suitable For Automatic Operation Consisting Of Following : ( Terrace Pump ) ( Make : Kirloskar / Mather+Platt ) ( A ) Horozontally Mounted, Split Casing, Centrifugal Fire Pump Complete For Delivery Of Under Mentioned Discharge Against Desired Mentioned Head So As To Ensure A Minimum Pressure Of 30 Meter At The Highest And Farthest Outlet At The Specified Flow Cmplete With Necessary Strainers, Pressure Gauge Including Bypass Arrangement For Periodic Testing Of The Working Of The Pumpset With Required Length And Size Of Medium Class Gi Pipe And Control Valves For Proper Completion Of Work.The Pump Shall Be Capable Of Giving 150% Of Rated Discharge At Head Not Less Than 65% Of Rated Head.The Pump Shall Be Provided With Mechanical Seals. The Impeller Shall Be Enclosed Type And Accurately Blanced Dynamically.The Pump Casing Shall Be Of Cast Iron, Impeller Shall Be Of Bronze And Shaft Shall Be Of Stainless Steel. ( B ) Squirrel Cage, Tefc Induction Motor Suitable For 415 V, 3 Phase Having Ip 55 Protection And Class B Insulation For The Above Pump And Flexible Coupling With The Pump.The Motor Shall B Rated For Continuous Duty And Shall Have Hp Rating Necessary To Drive Th Pump At 150% Of ItS Rated Discharge At 65% Of Rated Head. © Common Bed Plate Of Fabricated Mild Steel Channel Or Cast Iron Type. ( D ) Suitable Cement Concrete Pump Foundation And Vibration Clamping Arrangement As Required With Foundation Bolts, Anti Vibration Pads, Washers Etc. ( E ) Pressure Switch For Automatic Operation Of Motor Including Necessary Wiring Upto Control Panel. ( F ) Electrical Control Panel With Starter, 3 Pole Motor Protection Category Current Limiting Type Mccb, Indicating Light, Ammeter, Voltmeter, Selector Switches, CtS Protective Fuses, Single Phasing Protection, Dry Suction Cut Off Etc As Requrd As Per Standard Details.Discharge :450 Liter Per Minute Head : 35 Meter 367 ( A ) Horozontally Mounted, Split Casing, Centrifugal Fire Pump Complete For Delivery Of Under Mentioned Discharge Against Desired Mentioned Head So As To Ensure A Minimum Pressure Of 30 Meter At The Highest And Farthest Outlet At The Specified Flow Cmplete With Necessary Strainers, Pressure Gauge Including Bypass Arrangement For Periodic Testing Of The Working Of The Pumpset With Required Length And Size Of Medium Class Gi Pipe And Control Valves For Proper Completion Of Work.The Pump Shall Be Capable Of Giving 150% Of Rated Discharge At Head Not Less Than 65% Of Rated Head.The Pump Shall Be Provided With Mechanical Seals. The Impeller Shall Be Enclosed Type And Accurately Blanced Dynamically.The Pump Casing Shall Be Of Cast Iron, Impeller Shall Be Of Bronze And Shaft Shall Be Of Stainless Steel. 368 Fixing & Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank Isi : 12701 Marked Indicating The Bis License No. With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Over Flow Pipes But Without Fitting And Base Support For Tank. [ Sintex, Electroplast, Star, Lotus Or Equivalent Having Valid Isi License ] . 369 Supply Of Halon Free Portable Fire Extinguishers As Described Below: 370 4.5 Kg Carbon Dioxide Extinguisher, Is Marked, With High Pressure Discharge Tube, Horn, Control Valve, Cce Approved Cylinder 371 6 Kg Mono Ammonium Phosphate ( Abc ) Type Cartridge Operated Extinguishers 372 9 Kg Mono Ammonium Phosphate ( Abc ) Type Cartridge Operated Extinguishers 373 Providing, Fixing, Testing And Commissioning Of 50 Litres ( Trolley Mounted ) Mechanical Foam Type Fire Extinguisher. In Hp Mild Steel Cylinders Isi Marked Tac Approved Fitted With Pressure Indicating Gauge, Internal Tube, Squeeze Lever Type Valve Fully Charged Complete In All Respects Including Wall Suspension Bracket / Trolley Mounted And Confoming To Is:910 . 374 Providing, Fixing, Testing And Commissioning Of Co2 Type Fire Extinguisher Of Capacity 22.5 Kg Filled With Co2 Gas As Per Is 15222 With Controll Discharge Mechanism Fitted With Hose, Horn & Trolleyconfirms To Is 2878 Bearing Isi Mark. Co2 Cylinder As Per Is 7285 375 Fixing, Storing, Handling, Shifting, Installation, Testing And Commissioning Of Halon Free Portable Fire Extinguishers As Described Below: 376 Supply Of Fire Related Signages Printed On Photoluminescent U1000 Aluminium Sheet Of 1.0 Mm ( +-10% ) Containing Lumigen Ii As Base Chemical, Covered Under Uv Stablized Coating And Of Appropriate Size For Fixing On Wall, Door, Ceiling Etc. With Proper Clamps, Hangers, Cleats, Anchor Fasteners Etc. Complete. 377 Fixing Of Fire Related Signages Printed On Photoluminescent U1000 Aluminium Sheet Of 1.0 Mm ( +-10% ) Containing Lumigen Ii As Base Chemical, Covered Under Uv Stablized Coating And Of Appropriate Sizeincluding Fixing On Wall, Door, Ceiling Etc. With Proper Clamps, Hangers, Cleats, Anchor Fasteners Etc. Complete In All Respects As Directed By Engineer-In-Charge. 378 Supply Ofci Cover With Frame Light Weight Complete As Perdesign Size 600X600 Mm 379 Supply Ofci Cover With Frame Light Weight Complete As Perdesign Size 900X900 Mm 380 Boring / Drilling Bore Well Of Required Dia For Casing / Strainer Pipe, By Suitable Method Prescribed In Is: 2800 ( Part I ) , Including Collecting Samples From Different Strata, Preparing And Submitting Strata Chart / Bore Log, Including Hire & Running Charges Of All Equipments, Tools, Plants & Machineries Required For The Job, All Complete As Per Direction Of Engineer -In-Charge, Beyond 90 Metre & Upto 150 Metre Depth Below Ground Level.Drilling Of 250 Mm Dia Bore Hole Manually. 381 Supply Of Unplasticized Pvc Medium Well Screen ( Rms ) Pipes With Ribs, Conforming To Is: 12818, Fittings & Accessories Etc. All Complete, For All Depths, As Per Direction Of Engineer-In-Charge.150 Mm Nominal Size Dia 382 Assembling, Lowering And Fixing In Vertical Position In Bore Well Unplasticized Pvc Medium Well Screen ( Rms ) Pipes With Ribs, Conforming To Is: 12818, Including Hire & Labour Charges, Fittings & Accessories Etc. All Complete, For All Depths, As Per Direction Of Engineer-In-Charge.150 Mm Nominal Size Dia 383 Supply Of Stone Boulders Of Size Range 5 Cm To 20 Cm, In Recharge Pit, In The Required Thickness, For All Leads & Lifts, All Complete As Per Direction Of Engineer-In-Charge. 384 Supply Of Gravels Of Size Range 5 Mm To 10 Mm, In The Recharge Pit, Over The Existing Layer Of Boulders, In Required Thickness, For All Leads & Lifts, All Complete As Per Direction Of Engineer-In-Charge. 385 Supply Of Coarse Sand Of Size Range 1.5Mm To 2 Mm In Recharge Pit, In Required Thickness Over Gravel Layer, For All Leads & Lifts, All Complete As Per Direction Of Engineer -Incharge. 386 Filling, Spreading & Leveling Coarse Sand, Gravels & Stone Boulders Of Size Range 1.5 Mm To 20 Mm In Recharge Pit, In Required Thickness Over Gravel Layer, For All Leads & Lifts, All Complete As Per Direction Of Engineer -Incharge. 387 Transportation Charges Of Drilling Equipment Including Assembly And Other Material As Required. 388 Drilling Of 675 Mm. Dia By Rotary Machine 389 Supply Of 350 Mm. Dia Housing Pipe ( 8 Mm. Thick ) 390 Laying Of 350 Mm. Dia Housing Pipe ( 8 Mm. Thick ) 391 Supply Of 200 Mm. Dia Blind Pipe ( 8 Mm. Thick ) 392 Laying Of 200 Mm. Dia Blind Pipe ( 8 Mm. Thick ) 393 Supply Of 200 Mm. Dia Slotted Pipe ( 8 Mm. Thick ) 394 Laying Of 200 Mm. Dia Slotted Pipe ( 8 Mm. Thick ) 395 Supply Of 350 Mm. Dia Socket 396 Fixing Of 350 Mm. Dia Socket 397 Supply Of 200 Mm. Dia Socket 398 Fixing Of 200 Mm. Dia Socket 399 Supply Of 200 Mm. Dia Bail Plug 400 Fixing Of 200 Mm. Dia Bail Plug 401 Supply Of 350 Mm. Dia Well Cap 402 Fixing Of 350 Mm. Dia Well Cap 403 Supply Of 350X200 Mm. Dia Reducer. 404 Fixing Of 350X200 Mm. Dia Reducer. 405 Supply Of 350 Mm. Dia Housing Clamp 406 Fixing Of 350 Mm. Dia Housing Clamp 407 Supply Of Pee Gravel 2 Mm. 4 Mm. In Side Of Bore After Lower And Development As Required As Per Direction Of E / I. 408 Filling Of Pee Gravel 2 Mm. 4 Mm. In Side Of Bore After Lower And Development As Required As Per Direction Of E / I. 409 Development By Air Compressor Including Transportation. 410 Development By O.P. Unit Including Transportation. 411 Supply Of 7.5 Hp Ksb Make Submersible Pump Set Model Bpd 302 / 4+Uami 150 / 6 / 22-203 ( S / D ) Suitable For Tube Well Capable Of Pumping Clear And Cold Water Free From Chemical And Directly Coupled With Ksb Electric Moter Operating Of 415 Volt Suitable For 3 Phase 50 Cycle A.C. Supply Of Following Duty Condition 7.5 Hp 6 Stage Pipe.A - Discharge Of Water In Lpm 860 Approx Size Of Discharge Outlet In 80 Mm.B - Total Head Of Pump Set 45 M. 412 Supply Of Finolex Or Equivalent Isi Marked Submersible Copper Cable Of Size 2X3x2.5 Sq. Mm. 413 Fixing Of Finolex Or Equivalent Isi Marked Submersible Copper Cable Of Size 2X3x2.5 Sq. Mm. 414 Supply Of Control Panel Cubical Type Wall Mounted Vermin Proof With Internal Wiring Duly Enameled Painted And Mechanically Finished Having L&T Of Qul. Male Switch Fuse Unit With Hrc Fuses, Ameter, Boltmeter, Selector Switch, Phase Indicating Lamp With Bulbs, Instrument Fuses, Power Capcitor Single Phase Preventor Etc. Complete Set With Supply Of Jyoti Or Eq. Air Break Star- Delta Motro Starter Suitable For Above Submersible Pump Set. 415 Supply Of 80Mm Dia M.S. Column Pipe Of Class C Both And Socketed With Heavy Sockets In 3 / 6 Meter Length And One End Flanged Complete With Interlocking Arrangements. 416 Lowering Of 80Mm Dia M.S. Column Pipe Of Class C Both And Socketed With Heavy Sockets In 3 / 6 Meter Length And One End Flanged Complete With Interlocking Arrangements. 417 Supply Of 80Mm Dia M.S. Column Pipe Clamps With Nut, Bolts, Packing Etc. 418 Lowering Of 80Mm Dia M.S. Column Pipe Clamps With Nut, Bolts, Packing Etc. 419 Supply Of 80Mm Dia C.I. Double Flanged Isi Mark Reflex Valve Of Updadhya Or Equ. Make. 420 Fixing Ofc.I. Double Flanged Reflex Valve 421 Supply Of 80Mm Dia C.I. Double Flanged Isi Mark Sluice Valve With Hand Wheel Of Upadhya Or Equ. Make. 422 Supply Of 100 Mm Dia C.I. Double Flanged Isi Mark Sluice Valve With Hand Wheel Of Upadhya Or Equ. Make. 423 Supply Of 150Mm Dia C.I. Double Flanged Isi Mark Sluice Valve With Hand Wheel Of Upadhya Or Equ. Make. 424 Fixing Of 80 / 100 / 150 Mm Dia C.I. Double Flanged Isi Mark Sluice Valve With Hand Wheel 425 Supply Of C.I. Double Flanged Bend Of 80Mm Dia 426 Fixing Of C.I. Double Flanged Bend Of 80Mm Dia I / C Cost Of Labour. 427 Supply Of 80Mm Dia C.I. Tee Heavy Quality I / C Cost Of Material. 428 Fixing Of 80Mm Dia C.I. Tee Heavy Quality 429 Supply Of Guru / Fibing Or Equivalent Make Pressure Gauge. 430 Fixing Of Pressure Gauge. 431 Erection & Commissioning Of Pumping Plants Complete Along With Electric Wiring. 432 Supply Of Steel Wire Rope Of 1 / 2 Size 433 Fixing Of Steel Wire Rope Of 1 / 2 Size 434 S / B Of 600Mm X 600 Mm X 6.0 Mm G.I. Plate Vertically For Earthing With Its Top At Least 3 Metres Below Ground Level Complete With 20Mm Dia G.I. Pipe And Funnel For Watering And One Earthing Lead On One No. 8 To 10 Swg Gi Wite In 15Mm Dia G.I. Pipe Up To Switch Board ( From Appron To Switch Board The Cost Of G.I. , Pipe And G.I. Wire Will Be Extra ) 30 Cm Square C.I. Frame With Hinged Cover Masonry Housing Alternate Layers Of Charcoal. Coke And Salt At Least 150Mm Thick Alround Etc. As Per Directions Of E / I Complete In All Respects As Per Drawing. 435 S / F Of One Number 8 To 6 Swg G.I. Wire In 15Mm Dia G.I. Pipe For Earthing, Laid In Ground Or In Wall Duly Concealed Includingn The Cost Of Cement, Sand Labour. T&P Other Material Required For Proper Completion Of The Work As Directed At Site. 436 S / F Of Aluminium Conductor Pvc Insulated Armoured, Served, Sheathed Cable 1100 Volts Grade16 Sqmm X 4 Core 437 Fixing Of Aluminium Conductor Pvc Insulated Armoured, Served, Sheathed Cable 1100 Volts Grade At A Depth Of 750Mmbelow Ground Level Over A Cushion Of 75Mm Thick Sand Alround And Protected With Burnt Bricks On Sides And On Top.On Surface The Cable Run Shall Be Fixed On M.S. Clamps Etc. Of Suitable Size Or As Directed By E / I Complete In All Respects The Armoring Of The Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc.16 Sqmm X 4 Core 438 Supply Of 500 Kva. 11 / 0.433 Kv, 3Phase, 50Hz, Dyn 11, Oil Type, ( Uppcl Approved Make ) Copper Wound Transformer With Off Load Tap Changing Arrangement On Hv Side In Steps Of + / - 2.50%, + / - 5% & - 7.5% , Having Cable End Boxes On Hv Sideand 800 Amp. Bus Trunking Arrangement On Lv Side Complete With All Accessories I / C First Filling Of Filtered Dehydrated Oil And Confirming To Is 2026 ( Part 1 To Part 5 ) & As Per Specification Attached Complete In All Respects As Required At Site. 439 Installation, Testing And Commissioning Of 500 Kva. 11 / 0.433 Kv, 3Phase, 50Hz, Dyn 11, Oil Type, ( Uppcl Approved Make ) Copper Wound Transformer With Off Load Tap Changing Arrangement On Hv Side In Steps Of + / - 2.50%, + / - 5% & - 7.5% , Having Cable End Boxes On Hv Sideand 800 Amp. Bus Trunking Arrangement On Lv Side Complete With All Accessories I / C First Filling Of Filtered Dehydrated Oil And Confirming To Is 2026 ( Part 1 To Part 5 ) & As Per Specification Attached Complete In All Respects As Required At Site. 440 Supply Of 3 Core Standered Aluminium Conduktor Xlpe ( Cross Linked Polyethylene ) Insulated Pvc Bedded, Galvanised Flat Steel Strip Armoured Cables Confirming To I.S. 7098 ( Part-Ii With Latest Amendments ) 11 Kv Grade 150Sq. Mm 3 Core 441 Laying Of 3 Core Standered Aluminium Conduktor Xlpe ( Cross Linked Polyethylene ) Insulated Pvc Bedded, Galvanised Flat Steel Strip Armoured Cables Confirming To I.S. 7098 ( Part-Ii With Latest Amendments ) 11 Kv Grade At A Depht Of 900 Mm Below Ground Level Over A Cushion Of 100 Mm Thick Fine River Sand All Around And Protected With Well Burnt Bricks In Sides And On The Top Put Across. Thearmouring Of Cable Shall Be Properly Connected With Earth Condutor By Clamps Etc.150Sq. Mm 3 Core 442 Supply Of 3 Core 240Sq.Mm. Xlpe Aluminium Conductor Cable Of 11 Kv Grage As Required. 443 Making Indoor Cable End Jointing With Cast Resin Compound, Including Lugs And Other Jointing Materials, For 3 Core 240Sq.Mm. Xlpe Aluminium Conductor Cable Of 11 Kv Grage As Required. 444 Making Outdoor Cable End Jointing With Cast Resin Compound, Including Lugs And Other Jointing Materials, For 3 Core 240 Sq.Mm. Xlpe Aluminium Conductor Cable Of 11 Kv Grage As Required. 445 Supply And Burying Of 40Mm Dia X 4.5 Metres Long G.I. Pipe Vertically For Earthing Having 12Mm Dia. Holes Spaced 75Mm Apart Drilled Up To 2 Metre From The Bottom Complete With Earthing Lead Of No. 6 To 8 Swg Gi Wire In G.I. Pipe Up To Appron ( And From Appron To Switch Board The Cost Of G.I. Wire And Pipe Will Be Extra ) Upto Switch Board, 30Cm Square C.I. Box With Hinged Cover Masonary Enclosure, Funnel At Top, Alternate Layers Of Charcoal / Coke And Salt At Least 150Mm Thick Alround Etc. As Per Directions Of Engineer-In-Charge Complete In All Respects As Per Drawing. 446 Supply And Burying Of 600Mm X 600 Mmx6mm G.I. Plate, Vertically For Earthing With Its Top Atleast 3 Mts. Below Ground Level Complete With 20Mm G.I.Pipe And Funnel For Watering And Two Earthing Leads Of No.8To10swg G.I.Wire In 15Mm Diag.I. Pipe Upto Switch Board ( From Apron To Switch Board The Cost Of G.I. Pipe And G.I. Wire Will Be Extra ) 30Cm. Square C.I. Frame With Hinged Cover, Masonary Housing, Alternate Layers / Of Charcoal / Coke And Salt At Least 150Mm Thick Alround Etc. Complete In All Respects. 447 Supply And Burying Of 600Mm X 600Mm X 3 Mm Copper Plate Vertically For Earthing With Its Top At Least 3 Metres Below Ground Level Complete With 20Mm Dia G.I Pipe And Funnel For Watering And One Earthing Lead Ofone No. 8Swg Copper Wire In 15 Mm Dia G.I Pipe Up To Switch Board ( From Appron To Switch Board The Cost Of G.I Pipe And Copper Wire Will Be Extra ) 30 Cm Square C.I Frame With Hinged Cover Masonry Housingalternate Layers Of Charcoal / Coke And Salt Atleast 150Mm Thick Alround Etc. As Per Directions Of Engineer In Charge Complete In All Respects. 448 Supply And Laying Of 32Mm X 6Mm G.I. Strip From Earth Electrode Directly In The Ground As Required Complete In All Respects. 449 Supply And Laying Of 32Mm X 6 Mm Copper Strip From Earth Electrode Directly In The Ground As Required Complete In All Respects.. 450 Supply And Laying Of 25Mm X 3Mm G.I. Strip From Earth Electrode Directly In The Ground As Required Complete In All Respects. 451 Supply And Fixing Of One Number 8 Swg G.I Wire In 15Mm Dia. G.I Pipe For Earthing Laid In Ground Or In Wall Duly Concealed Including The Cost Of Cement, Sand, Labour, T&P Other Material Required For Proper Completion Of The Work As Directed At Site. 452 Supply Of Aluminium Conducter, Pvc Insulated Armoured, Served, Sheeted Cable 1000 Bolts Grade 453 300 Sqmm3.5 Core 454 185 Sqmm3.5 Core 455 150 Sqmm3.5 Core 456 35 Sqmm3.5 Core 457 25 Sqmm3.5 Core 458 16 Sqmm4 Core 459 10 Sqmm4 Core 460 16 Sqmm2 Core 461 10 Sqmm2 Core 462 6 Sqmm2 Core 463 Laying Of Aluminium Conducter, Pvc Insulated Armoured, Served, Sheeted Cable 1000 Bolts Grade At A Depth Of 750Mm Below Ground Level Over A Cushion Of 75Mm Thick Sand Alround And Protected With Burnt Bricks On Sides And Top On Surface, The Cable Run Shall Be Fixed On M.S. Clamps Etc. Of Suitable Size. From 6 Sqmm 2 Core To 300 Sqmm3.5 Core 464 Supply Of Brass Nickle Plated Compression Gland For Pvc Insulated & Armoured Served Sheathed, Underground Cable Including Rubber Ring Etc. Complete 465 300 Sqmm3.5 Core 466 185 Sqmm3.5 Core 467 150 Sqmm3.5 Core 468 35 Sqmm3.5 Core 469 25 Sqmm3.5 Core 470 16 Sqmm4 Core 471 10 Sqmm4 Core 472 16 Sqmm2 Core 473 10 Sqmm2 Core 474 6 Sqmm2 Core 475 Fixing Of Brass Nickle Plated Compression Gland For Pvc Insulated & Armoured Served Sheathed, Underground Cable Including Rubber Ring Etc. Complete In All Respects. The Armouring Of The Cable Shall Be Properly Connected With The Earth As Per Direction Of Eic. From 6 Sqmm 2 Core To 300 Sqmm3.5 Core 476 Supply Of Palm / Pin Type Copper Tin Plated Cables Sockets ( Lugs ) To The Cable Leads, Insuslating With Tape 477 300 Sqmm 478 185 Sqmm 479 150 Sqmm 480 95 Sqmm 481 70 Sqmm 482 35 Sqmm 483 25 Sqmm 484 16 Sqmm 485 10 Sqmm 486 6 Sqmm 487 4 Sqmm 488 Fixing Of Palm / Pin Type Copper Tin Plated Cables Sockets ( Lugs ) To The Cable Leads, Insuslating With Tape And Making Of Connections Etc. Complete In All Respects As Per Direction Of Engineer-Incharge. From 4 Sqmmto 300 Sqmm 489 Supply Of 7 Mtr Gi Octagonal Pole Of Approved Make ( Top Dia 70Mm, Bottom Dia 130 Mm And Base Plate 12 Mm Thik ) Having 3Mm Thikness With Single Arm Bracket ( 1 Mtr Length ) Including The Cost Of Foundation Bolts, Required T&P Complete In All Respect. 490 Fixing Of 7 Mtr Gi Octagonal Pole Of Approved Make ( Top Dia 70Mm, Bottom Dia 130 Mm And Base Plate 12 Mm Thik ) Having 3Mm Thikness With Single Arm Bracket ( 1 Mtr Length ) On Rcc Foundation Including The Cost Of Foundation, Foundation Bolts, Excavation & Back Filling And Required T&P Complete In All Respect. 491 Supply Of Led Street Light Fitting Having Die Cast Aluminium Body And Diffuser With Driver Set Suitable For 45 Watt To 50 Watt. Confirming To Ip 66 And Above Protection Complete In All Respect. 492 Fixing Of Led Street Light Fitting Having Die Cast Aluminium Body And Diffuser With Driver Set Suitable For 45 Watt To 50 Watt. Confirming To Ip 66 And Above Protection Complete In All Respect. 493 Supply Of 6 Amp To 32 Amp Dp Mcb ( 10Ka ) ( C Curve ) For Poles 494 Fixing Of 6 Amp To 32 Amp Dp Mcb ( 10Ka ) ( C Curve ) For Poles 495 Supply Of Decorative 40 To 45 Watt Led Post Top Indirect Light Luminaire Having Pressure Die Cast Aluminium Body And Clear Glass With Driver Set Confirming To Ip 65 And Above Protection Complete In All Respect. 496 Fixing Of Decorative 40 To 45 Watt Led Post Top Indirect Light Luminaire Having Pressure Die Cast Aluminium Body And Clear Glass With Driver Set Confirming To Ip 65 And Above Protection Complete In All Respect. 497 Supply Offollowing Capacity Of Automatic Street Light Cubicle Control Panel Painted With Anti Corrosive Alkali And Acid Proof Paint Consisting Of Time Switch Tso 100 Series With Contractors, Hrc Fuses, Isolating Switch Metering Instrument & Instrument Box With Cts Etc. In Case Of Tpn Complete In All Respect.25 Amp Spn 498 Fixing Following Capacity Of Automatic Street Light Cubicle Control Panel Painted With Anti Corrosive Alkali And Acid Proof Paint Consisting Of Time Switch Tso 100 Series With Contractors, Hrc Fuses, Isolating Switch Metering Instrument & Instrument Box With Cts Etc. In Case Of Tpn Complete In All Respect.25 Amp Spn 499 Supply Of Bakelite Sheet 3 Mm Thick Of Suitable Size & Connector 500 Fixing Of Bakelite Sheet 3 Mm Thick Of Suitable Size & Connector 501 Supply Of M.S. Pipe ( Class B- Is : 1239 ) Pole Suitable For Fixing 70 Watt. Hpsv Post Top Including 4 Pole Cable Junction Box With 5 Amp. Rewireablefuse Fitting And 5 Amp. Switch On Laminated Cover And M.S. Box Complete With Water Tight Cover And 450X450x450mm Base Above Ground And 2X4sqmm Aluminium Wire From Cable Box To Lamp For Connection Including Painting The Pole On Primer Coats And Necessary Reducers On Thetop Of Pole For Fixing Of Post Top Lantern. 65Mm Dia 4M Long ( 3M Above Ground And 1 M Below Ground ) . 502 Fixing Of M.S. Pipe ( Class B- Is : 1239 ) Pole Suitable For Fixing 70 Watt. Hpsv Post Top Including 4 Pole Cable Junction Box With 5 Amp. Rewireablefuse Fitting And 5 Amp. Switch On Laminated Cover And M.S. Box Complete With Water Tight Cover Includingmasonary / Pcc ( 1:3:6 ) Work For Erecting The Pole And 450X450x450mm Base Above Ground And 2X4sqmm Aluminium Wire From Cable Box To Lamp For Connection Including Painting The Poleby An Approved Shade On Primer Coats And Necessary Reducers On Thetop Of Pole For Fixing Of Post Top Lantern.The Work Shall Be Complete As Required Up To The Satisfaction Of Engg.-In-Charge.65Mm Dia 4M Long ( 3M Above Ground And 1 M Below Ground ) . 503 Making Of Following Size Of Cable Chamber Made Of 230 Mm Thick Brick Work In Cement Mortar ( 1 Cement : 6 Sand ) With Pcc 100 Mm Thick Pcc Base Plastering Of Inner And Outer Surface With Cement Mortar Including Providing Of Heavy Duty C.I Cover Complete With Digging, Refilling And Removal Of Surplus Soil Complete As Required. Material Cost Will Be Paid Saperately.900 Mm X 900 Mmx 1000 Mm Deep 504 Supply Of Mv Danger Notice Plate Of 200 Mm X 150 Mm Made Of Mild Steel At Least 2Mmthick &Vitreousenamelledwhiteon Bothsides And Withinscription Insignalred Colouronfront Side As Required. 505 Supply Of Ht Danger Notice Plate 250 Mm X 200 Mm Made Of Mild Steel At Least 2Mmthick &Vitreousenamelledwhiteon Bothsides And Withinscription Insignalred Colouronfront Side As Required. 506 Fixing Of Mv / Ht Danger Notice Plate 250 Mm X 200 Mm Made Of Mild Steel At Least 2Mmthick &Vitreousenamelledwhiteon Bothsides And Withinscription Insignalred Colouronfront Side As Required. 507 Supplying Of Fire Buckets, Round Bottom Made Of G.I. Sheet 9-11 Litres Capacity Duly Painted As Per Fire Brigade Design, Supported On Hanging Bracket Chained And Locked, Initially Filled With Fine River Sand, Water As Per Directions Of Engineer-In-Charge. 508 Fixing Of Fire Buckets, Round Bottom Made Of G.I. Sheet 9-11 Litres Capacity Duly Painted As Per Fire Brigade Design, Supported On Hanging Bracket Chained And Locked, Initially Filled With Fine River Sand, Water As Per Directions Of Engineer-In-Charge. 509 Supply Of 1800 Mm X 900 Mm X 12 Mm Thick Chequered Rubber Matting Of Tested Quality 510 Layingof 1800 Mm X 900 Mm X 12 Mm Thick Chequered Rubber Matting Of Tested Quality 511 Supply Of Danger Board Fabricated From 10 Gauge Ms Sheet As Per Ie Rules 512 Fixing Of Danger Board Fabricated From 10 Gauge Ms Sheet As Per Ie Rules 513 Supply Of Shock Treatment Chart ( Prescribed Under I.E.Rules ) Duly Framed With Glass And Supported From Back With Hard Board Or Soft Board. 514 Fixing Of Shock Treatment Chart ( Prescribed Under I.E.Rules ) Duly Framed With Glass And Supported From Back With Hard Board Or Soft Board With Supply Of All Labour T & Pfor Proper Completion Of Work. 515 Supply Of Fire Extinguishers, Abc Type 4.00 Kg. Capacity ( Isi Marked Is : 15683 & Tac Approved ) Complete With Initial Charges And Wall Bracket, 516 Supply Of Co2 Typefire Extinguishers, 4.50 Kg. Capacity ( Isi Marked Is : 2878 & Tac Approved ) Complete With Initial Charges And Wall Bracket, 517 Fixing Of Fire Extinguishers, Abc Type 4.00 Kg. & Co2 Type 4.5 Kg. Capacity Complete With Initial Charges And Wall Bracket, Along With Supply Of All Labour For Proper Completion Of Work. 518 Supply Of Water Closet Squatting Pan ( Indian Type W.C. Pan ) With 100Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern With Manually Controlled Device ( Handle Lever ) Conforming To Is:7231, Parryware / Hindware / Seabird / Orient ( Coral ) With All Fittings And Fixtures Complete.White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440mm With Integral Type Foot Rests 519 Fixing Of Water Closet Squatting Pan ( Indian Type W.C. Pan ) With 100Mm Sand Cast Iron P Or S Trap, 10 Litre Low Level White P.V.C. Flushing Cistern With Manually Controlled Device ( Handle Lever ) Conforming To Is:7231, Parryware / Hindware / Seabird / Orient ( Coral ) With All Fittings And Fixtures Complete Including Cutting And Making Good The Walls And Floors Wherever Required.White Vitreous China Orissa Pattern W.C. Pan Of Size 580X440mm With Integral Type Foot Rests 520 Supply Of White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, Parryware / Hindware / Seabrid / Orient ( Coral ) With All Fittings And Fixtures Complete.W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid 521 Fixing White Vitreous China Pedestal Type Water Closet ( European Type W.C. Pan ) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern With Manually Controlled Device ( Handle Lever ) , Conforming To Is : 7231, Parryware / Hindware / Seabrid / Orient ( Coral ) With All Fittings And Fixtures Complete Including Cutting And Making Good The Walls And Floors Wherever Required : W.C. Pan With Isi Marked Black Solid Plastic Seat And Lid 522 Supply Of White Vitreous China Extended Wall Mounting Water Closet Of Size 780X370x690mm Of Approved Shape Including Providing & Fixing White Vitreous China Cistern With Dual Flush Fitting, Of Flushing Capacity 3 Litre / 6 Litre ( Adjustable To 4 Litre / 8 Litres ) , Including Seat Cover, And Cistern Fittings, Nuts, Bolts And Gasket Etc Complete. 523 Fixing Of White Vitreous China Extended Wall Mounting Water Closet Of Size 780X370x690mm Of Approved Shape Including Providing & Fixing White Vitreous China Cistern With Dual Flush Fitting, Of Flushing Capacity 3 Litre / 6 Litre ( Adjustable To 4 Litre / 8 Litres ) , Including Seat Cover, And Cistern Fittings, Nuts, Bolts And Gasket Etc Complete. 524 Supply Of White Vitreous China Wash Basin With C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps, C.P. Brass Chain With Rubber Plug, 32Mm C.P. Brass Waste Of Standerd Pattern. 525 A ) White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps 526 B ) White Vitreous China Surgeon Type Wash Basin Of Size 660X460 Mm With Single 15 Mm C.P. Brass Pillar Tapswith Elbow Operated Levers Isi Marked 527 Fixing Of White Vitreous China Wash Basin With C.I. Brackets Painted White, 15 Mm C.P. Brass Pillar Taps, C.P. Brass Chain With Rubber Plug, 32Mm C.P. Brass Waste Of Standerd Pattern Including Cutting & Making Good The Walls Wherever Required. 528 A ) White Vitreous China Wash Basin Size 630X450 Mm With A Pair Of 15 Mm C.P. Brass Pillar Taps 529 B ) White Vitreous China Surgeon Type Wash Basin Of Size 660X460 Mm With Single 15 Mm C.P. Brass Pillar Tapswith Elbow Operated Levers Isi Marked 530 Supply Of P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. 531 Semi Rigid Pipe 532 32 Mm Dia 533 40 Mm Dia 534 Fixing Of P.V.C. Waste Pipe For Sink Or Wash Basin Including P.V.C. Waste Fittings Complete. 535 Semi Rigid Pipe 536 32 Mm Dia 537 40 Mm Dia 538 Supply Of 600X450mm Bevelled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. 539 Fixing Of 600X450mm Bevelled Edge Mirror Of Superior Glass ( Of Approved Quality ) Complete With 6Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. 540 Supply Of Stainless Steel Aisi 304 ( 18 / 8 ) Kitchen Sink As Per Is : 13983 With C.I. Brackets And Stainless Steel Plug 40Mm Including Painting Of Fittings And Brackets, Kitchen Sink With Drain Board Size 510X1040 Mm Bowl Depth 250Mm 541 Fixing Of Stainless Steel Aisi 304 ( 18 / 8 ) Kitchen Sink As Per Is : 13983 With C.I. Brackets And Stainless Steel Plug 40Mm Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherrerever Required.Kitchen Sink With Drain Board Size 510X1040 Mm Bowl Depth 250Mm 542 Supply Of White Vitreous China Flat Back Half Stall Urinal Of Size 580*380*350Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pipe, Spreaders With Unions And Clamps ( All In D.P. Brass ) With Waste Fitting As Per Is : 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass Including Painting Of Fittings. 543 Range Of Three Half Stall Urinals With 10 Litre Pv.C. Automatic Flushing Cistern. 544 Range Of Two Half Stall Urinals With 5 Litre Pv.C. Automatic Flushing Cistern. 545 Range Of Single Half Stall Urinals With 5 Litre Pv.C. Automatic Flushing Cistern. 546 Fixing White Vitreous China Flat Back Half Stall Urinal Of Size 580*380*350Mm With White Pvc Automatic Flushing Cistern, With Fittings, Standard Size C.P. Brass Flush Pipe, Spreaders With Unions And Clamps ( All In D.P. Brass ) With Waste Fitting As Per Is : 2556, C.I. Trap With Outlet Grating And Other Couplings In C.P. Brass Including Painting Of Fittings And Cutting And Making Good The Walls And Floors Wherever Required: 547 Range Of Three Half Stall Urinals With 10 Litre Pv.C. Automatic Flushing Cistern. 548 Range Of Two Half Stall Urinals With 5 Litre Pv.C. Automatic Flushing Cistern. 549 Range Of Single Half Stall Urinals With 5 Litre Pv.C. Automatic Flushing Cistern. 550 Fixing Of Stone Slab Table Rubbed, Edges Rounded And Polished Of Size 75X50cm Deep And 1.8Cm Thick Fixed In Urinal Partitions By Cutting A Chase Of Appropriate Width With Chase Cutter And Embedding The Stone In The Chase With Epoxy Grout Or With Cement Concrete 1:2:4 ( 1Cement: 2Coarse Sand: 4Graded Stone Aggregate 6Mm Nominal Size ) As Per Direction Of Engineer-In-Charge And Finished Smooth.Granite Stone Of Approved Shade 551 Supply Of Unplasticised Pvc Connection Pipe With Brass Unions 552 45 Cm Length 553 15 Mm Nominal Bore 554 Fixing Of Unplasticised Pvc Connection Pipe With Brass Unions 555 45 Cm Length 556 15 Mm Nominal Bore 557 Supply Of C.P. Brass Bib Cock Of Approved Quality Conforming To Is:8931 A ) 15 Mm Nominal Bore 558 Fixing Of C.P. Brass Bib Cock Of Approved Quality Conforming To Is:8931V A ) 15 Mm Nominal Bore 559 Supply Of C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards Andweighing Not Less Than 690 Gms.A ) 15 Mm Nominal Bore 560 Fixing Of C.P. Brass Long Body Bib Cock Of Approved Quality Conforming To Is Standards Andweighing Not Less Than 690 Gms.A ) 15 Mm Nominal Bore 561 Supply Of C.P. Brass Angle Valve For Basin Mixer And Gyser Points Of Approved Quality Conforming To Is:8931A ) 15 Mm Nominal Bore 562 Fixing Of C.P. Brass Angle Valve For Basin Mixer And Gyser Points Of Approved Quality Conforming To Is:8931A ) 15 Mm Nominal Bore 563 Supply Of C.P. Brass Shower Rose With 15 Or 20Mm Inlet 150 Mm Diameter 564 Fixing Of C.P. Brass Shower Rose With 15 Or 20Mm Inlet150 Mm Diameter 565 Supply Of C.P. Brass Stop Cock ( Concealed ) Of Standard Design And Of Approved Make Conforming To Is:8931: 150 Mm Diameter 566 Fixing Of C.P. Brass Stop Cock ( Concealed ) Of Standard Design And Of Approved Make Conforming To Is:8931: 150 Mm Diameter 567 Supply Of Ptmt Bottle Trap For Wash Basin And Sink.Bottle Trap 31Mm Single Piece Moulded With Height Of 270 Mm, Effective Length Of Tail Pipe 260 Mm From The Centre Of The Waste Coupling, 77 Mm Breadth With 25 Mm Minimum Water Seal, Weighing Not Less Than 260 Gms 568 Fixing Of Ptmt Bottle Trap For Wash Basin And Sink.Bottle Trap 31Mm Single Piece Moulded With Height Of 270 Mm, Effective Length Of Tail Pipe 260 Mm From The Centre Of The Waste Coupling, 77 Mm Breadth With 25 Mm Minimum Water Seal, Weighing Not Less Than 260 Gms 569 Supply Of Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms. 570 Fixing Of Ptmt Liquid Soap Container 109 Mm Wide, 125 Mm High And 112 Mm Distance From Wall Of Standard Shape With Bracket Of The Same Materials With Snap Fittings Of Approved Quality And Colour, Weighing Not Less Than 105 Gms. 571 Supply Of Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour. 450 Mm Long Towel Rail With Total Length Of 495 Mm, 78 Mm Wide And Effective Height Of 88 Mm, Weighing Not Less Than 170 Gms 572 Fixing Of Ptmt Towel Rail Complete With Brackets Fixed To Wooden Cleats With Cp Brass Screws With Concealed Fittings Arrangement Of Approved Quality And Colour.450 Mm Long Towel Rail With Total Length Of 495 Mm, 78 Mm Wide And Effective Height Of 88 Mm, Weighing Not Less Than 170 Gms 573 Supply Of Unplasticised-Pvc Pipe Clips Of Approved Design To Unplasticised-Pvc Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With Ms Screws 574 110Mm 575 90Mm 576 Fixing Of Unplasticised-Pvc Pipe Clips Of Approved Design To Unplasticised-Pvc Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With Ms Screws Of Required Length Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete. 577 110Mm 578 90Mm 579 Laying Of Cement Concrete 1:5:10 ( 1 Cement : 5 Coarse Sand : 10 Graded Stone Aggregate 20Mm Nominal Size ) Around P.V.C Soil And Waste Pipe Including Bed Concrete As Per Standard Design ( Embedded In The Flooring / Ground ) 580 100 / 75 Mm Dia 581 Supply Of Wall Face Unplasticised-Rigid Pvc Rain Water Pipes Conforming To Is: 13592 Type A110 Mm 582 Fixing On Wall Face Unplasticised-Rigid Pvc Rain Water Pipes Conforming To Is: 13592 Type A Including Jointing With Seal Ring Conforming To Is: 5382 Leaving 10Mm Gap For Thermal Expansion. 110 Mm 583 Supply Of Wall Face Unplasticised Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is:13592. 584 Bend 87.5 Degree 585 110 Mm Bend 586 Shoe ( Plain ) 110 Mm Shoe 587 Fixing Of Wall Face Unplasticised Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is:13592Type A Including Jointing With Seal Ring Conforming To Is:5382 Leaving 10Mm Gap For Thermal Expansion. 588 Bend 87.5 Degree 589 110 Mm Bend 590 Shoe ( Plain ) 110 Mm Shoe 591 Supply Of Inlet Mouth Of Rain Water Pipe Cast Iron Grating 15 Cm Diameter And Weighing Not Less Than 440 Grams. 592 Fixing Of The Inlet Mouth Of Rain Water Pipe Cast Iron Grating 15 Cm Diameter And Weighing Not Less Than 440 Grams. 593 Supply Of Unplasticised-Pvc Pipe Clips Of Approved Design To Unplasticised-Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With Ms Screws Of Required Length. 110 Mm 594 Fixing Of Unplasticised-Pvc Pipe Clips Of Approved Design To Unplasticised-Pvc Rain Water Pipes By Means Of 50X50x50 Mm Hard Wood Plugs, Screwed With Ms Screws Of Required Length Including Cutting Brick Work And Fixing In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) And Making Good The Wall Etc. Complete.110 Mm 595 Making Khurras 45X45 Cm With Average Minimum Thickness Of 5 Cm Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate Of 20 Mm Nominal Size ) Over Pvc Sheet 1M X 1 M X 400 Micron, Finished With 12 Mm Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand ) And A Coat Of Neat Cement, Punning, Rounding The Edges And Making And Finishing The Outlet Complete. 596 Supply Of Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I / C Fixing The Pipe With Clamps At 1.00M Spacing. 597 20Mm Dia Nominal Outer Dia Pipes 598 25Mm Dia Nominal Outer Dia Pipes 599 32Mm Dia Nominal Outer Dia Pipes 600 Fixing Of Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I / C Fixing The Pipe With Clamps At 1.00M Spacing.This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testiang Of Joints Complete As Per Direction Of Engineer In Charge. 601 Concealed Work Including Cutting Chases And Making Good The Walls Etc. 602 20Mm Dia Nominal Outer Dia Pipes 603 25Mm Dia Nominal Outer Dia Pipes 604 32Mm Dia Nominal Outer Dia Pipes 605 Supply Of Gi Pipes Complete With Gi Fittings And Clamps. 606 15Mm Dianominal Bore 607 20Mm Dianominal Bore 608 25Mm Dia Nominal Bore 609 32Mm Dia Nominal Bore 610 40Mm Dia Nominal Bore 611 50Mm Dia Nominal Bore 612 65Mm Dia Nominal Bore 613 Fixing Of Gi Pipes Complete With Gi Fittings And Clamps, Including Cutting And Making Good Walls Etc. ( Internal Work ) . Internal Work-Exposed On Wall 614 15Mm Dianominal Bore 615 20Mm Dianominal Bore 616 25Mm Dia Nominal Bore 617 32Mm Dia Nominal Bore 618 40Mm Dia Nominal Bore 619 50Mm Dia Nominal Bore 620 65Mm Dia Nominal Bore 621 Painting Of Gi Pipes And Fittings With Synthetic Enamel Paint Over A Ready Mixed Priming Coat, Both Of Approved Quality For New Work. 622 15Mm Dia Nominal Bore 623 20Mm Dia Nominal Bore 624 25Mm Dia Nominal Bore 625 32Mm Dia Nominal Bore 626 40Mm Dia Nominal Bore 627 50Mm Dia Nominal Bore 628 65Mm Dia Nominal Bore 629 Supply Of Gi Union In Gi Pipes 630 15Mm Dia Nominal Bore 631 20Mm Dia Nominal Bore 632 25Mm Dia Nominal Bore 633 32Mm Dia Nominal Bore 634 40Mm Dia Nominal Bore 635 50Mm Dia Nominal Bore 636 65Mm Dia Nominal Bore 637 Fixing Of Gi Union In Gi Pipes Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete ( New Work ) . 638 15Mm Dia Nominal Bore 639 20Mm Dia Nominal Bore 640 25Mm Dia Nominal Bore 641 32Mm Dia Nominal Bore 642 40Mm Dia Nominal Bore 643 50Mm Dia Nominal Bore 644 65Mm Dia Nominal Bore 645 Supply Of Gun Metal Gate Valve With Wheel Of Approved Quality. 646 25Mm Dia Nominal Bore 647 32Mm Dia Nominal Bore 648 40Mm Dia Nominal Bore 649 50Mm Dia Nominal Bore 650 65Mm Dia Nominal Bore 651 Fixing Of Gun Metal Gate Valve With Wheel Of Approved Quality. 652 25Mm Dia Nominal Bore 653 32Mm Dia Nominal Bore 654 40Mm Dia Nominal Bore 655 50Mm Dia Nominal Bore 656 65Mm Dia Nominal Bore 657 Supply Of Brass Stop Cock Of Approved Quality. 658 B ) 20 Mm Nominal Bore 659 Fixing Of Brass Stop Cock Of Approved Quality. 660 B ) 20 Mm Nominal Bore 661 Supply Of Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank Isi : 12701 Marked Indicating The Bis License No. With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Over Flow Pipes But Without Fitting And Base Support For Tank. [ Sintex, Electroplast, Star, Lotus Or Equivalent Having Valid Isi License ] . 662 Fixing & Placing Of Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank Isi : 12701 Marked Indicating The Bis License No. With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Over Flow Pipes But Without Fitting And Base Support For Tank. [ Sintex, Electroplast, Star, Lotus Or Equivalent Having Valid Isi License ] . 663 Supply Of Glazed Stoneware Pipes Grade A100Mm Dia Sw Pipe 664 Laying And Jointing Glazed Stoneware Pipes Grade A With Stiff Mixture Of Cement Mortar In The Proportion Of 1:1 ( 1 Cement : 1 Fine Sand ) Including Testing Of Joints Etc. Complete.100Mm Dia Sw Pipe 665 Laying Cement Concrete 1:5:10 ( 1 Cement: 5 Coarse Sand : 10 Graded Stone Aggregate 40Mm Nominal Size ) All Rounds.W. Pipes Including Bed Concrete As Per Standard Design 100Mm Dia Sw Pipe 666 Supply Of Square-Mouth S.W. Gully Trap Grade‘A’ Complete With C.I. Grating, Water Tight C.I. Cover With Frame Of 300 X300 Mm Size ( Inside ) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design 150 X 100 Mm Size P Type 667 Fixing Of Square-Mouth S.W. Gully Trap Grade‘A’ Complete With C.I. Grating, Brick Masonry Chamber With Water Tight C.I. Cover With Frame Of 300 X300 Mm Size ( Inside ) The Weight Of Cover To Be Not Less Than 4.50 Kg And Frame To Be Not Less Than 2.70 Kg As Per Standard Design150 X 100 Mm Size P Type 668 Supply Of Floor And Wall Face Ringfit Upvc Astral Ultradrain Conventional System For Soil And Waste Water Pipes Conforming To ( Hsn Code: 3917 ) Type B ( I ) Double Socketed Pipes. 669 A ) 110Mm Dia P.V.C. Pipe 670 B ) 90Mm Dia P.V.C. Pipe 671 Fixing Of Floor And Wall Face Ringfit Upvc Astral Ultradrain Conventional System For Soil And Waste Water Pipes Conforming To ( Hsn Code: 3917 ) Type B Including Jointing With Seal Ring. ( I ) Double Socketed Pipes. 672 A ) 110Mm Dia P.V.C. Pipe 673 B ) 90Mm Dia P.V.C. Pipe 674 Supply Of Upvc Floor Trap Of Self Cleansing Designwith Cp Jalicomplete In All Respects. ( Make : Supreme / Finolex / Prince ) P-Trap Type Floor Trap 110 X 90Mm 675 Fixing Of Upvc Floor Trap Of Self Cleansing Designwith Cp Jalicomplete In All Respects. ( Make : Supreme / Finolex / Prince ) P-Trap Type Floor Trap 110 X 90Mm 676 Supply Of Clean Out Plug ( Astral ) 677 Fixing Of Clean Out Plug ( Astral ) 678 Supply Ofterminal Guard. 679 A ) 110Mm 680 B ) 90Mm 681 Fixing Of Terminal Guard. 682 A ) 110Mm 683 B ) 90Mm 684 Supply Of Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Pipes. 685 110Mm Bend 686 90 Mm Bend 687 110Mm Coupler 688 90Mmcoupler 689 110X110x110 Mm Single Tee With Door 690 90X90x90 Mm Single Tee With Door 691 Fixing Of Wall Face Unplasticised - Pvc Moulded Fittings / Accessories For Unplasticised Rigid Pvc Pipes Including Jointing With Seal Ring Leaving 10 Mm Gap For Thermal Expansion. 692 110Mm Bend 693 90 Mm Bend 694 110Mm Coupler 695 90Mmcoupler 696 110X110x110 Mm Single Tee With Door 697 90X90x90 Mm Single Tee With Door 698 Supply Of 1.50 Sqmm Frlsh Pvc Insulated Single Core Copper Conductor Cable 699 Supply Of 2.50 Sqmm Frlsh Pvc Insulated 1100 V Single Core Multistrand Copper Conductor Cable 700 Supply Of 4.00 Sqmm Frlsh Pvc Insulated 1100 V Single Core Multistrand Copper Conductor Cable 701 Supply Of 6.00 Sqmm Frlsh Pvc Insulated 1100 V Single Core Multistrand Copper Conductor Cable 702 Supply Of 10 Sqmm Frlsh Pvc Insulated 1100 V Single Core Multistrand Copper Conductor Cable 703 Supply Of 16 Sqmm Frlsh Pvc Insulated 1100 V Single Core Multistrand Copper Conductor Cable 704 Supply Of 25 Sqmm Frlsh Pvc Insulated 1100 V Single Core Multistrand Copper Conductor Cable 705 Supply Of Hexagonal / Round Gp Fan Box Of Approved Make Made Up Of 1 Mm Thick Isi Marked Gp Sheet Spot Welded Four To Eight Holes Of 25.4 Mm For Pipe Entry Of The Box Duly Screewed Fitted With 300 Mm Round Zink Coated Ms Bar X 12 Mm. 706 Supply Of Ceiling Fan With Fan Motor Of Ac Permanent Insulation, Capacitor Rating Conforming To Bee 5 Star. The Ratrd Voltage220 / 240 Volts, 50 Hz, Single Phase, Ac The Fan Assemble Should Consists Of Down Road Blades, Shackle Canopies With Double Ball Bearing System – 1200 Mm Sweep 707 Supply Of Electronic Fan Regulator ( Modular ) 120- 280 V Isi Marked 708 Supply Of Led Tube Light With Metal Heavy Duty Box Type Batten Light Fitting 2X 22 Watt Suitable For 2X22 Watt Polycarbonate Tube Light Including Tube Etc Suitable For Both Surface. 709 Supply Of Led Tube Light With Metal Heavy Duty Box Type Batten Light Fitting 1X 22 Watt Suitable For 1X22 Watt Polycarbonate Tube Light Including Tube Etc Suitable For Both Surface. 710 Supply Of Recess / Surface Mounting Round 10 To 15 Watt, Cut Out 125 Mm, Height Min 40 Mm, Led Downlighter Having Powder Coated Die Cast Aluminium Housing With Heat Sink, Diffuser / Reflector And Driver Set, Suitable For 24 Hr Continuousoperation 711 Supply Of Single Led Light Wall Bracket On Matching Mdfeg Board Base 712 Water Tight Oblong 10 Watt Led Bulkhead Luminery With Driver Set Conforming To Ip 65 And Above Protection Complete. 713 Supply Of Surface / Flush Mounting Distribution Boards With Additional Metal Door Without Mcb Complete. ( Cat A ) 714 4 Way Tpn 715 6 Way Tpn 716 8 Way Tpn 717 Supply Of 6 Amp To 32 Amp ( 10 Ka ) Sp Mcb ( Cat A ) 718 Supply Of Following Mcbs 719 40 Amp. Fp Mcb ( Cat A ) 720 63 Amp. Fp Mcb ( Cat A ) 721 40 Amp. Tp Mcb ( Cat A ) 722 63 Amp. Tp Mcb ( Cat A ) 723 Supply Of Surface / Flush Mounting V Tpn Distribution Boards With Additional Metal Door Without Mcb Complete. 4 Way V Tpn 724 Supply Of Following Mccbs 725 63 Amp. Fp Mccb ( Cat A ) 726 100 Amp. Fp Mccb ( Cat A ) 727 125 Amp. Fp Mccb ( Cat A ) 728 160 Amp. Fp Mccb ( Cat A ) 729 Supply Of Power Plug With 15 A / 250 V Flush Type Switch And 5 Pin 15 A / 250 V Flush Type Universal Socket In Suitable Ms Box 175Mmx100mmx50mm Size ( Modular ) 730 Supply Of Single Pole Mcbs Blanking Plate Complete 731 Supply Of Gi Plate For Earthing Size 600 Mm X 600Mm X 6 Mm 732 Supply Of Gi Pipe 20 Mm Dia 733 Supply Of Gi Wire 8 To 10 Swg 734 Supply Of Ci Frame ( 30 Sqcm ) With Hinged Cover 735 Supply Of Gi Strip For Earthing Purpose 25 Mmx 3 Mm 736 Supply Of Aluminium Conductor Pvc Insulated Armoured, Served, Sheeted Cable 1000 Volts 737 95 Sqmm 3.5 Core 738 70 Sqmm 3.5 Core 739 50 Sqmm 3.5 Core 740 35 Sqmm 3.5 Core 741 25 Sqmm 3.5 Core 742 10 Sqmm 4 Core 743 Supply Of Brass Nickle Plated Compression Gland For Pvc Insulated And Armoured Served Sheeted Underground Cable Including Rubber Ring 744 95 Sqmm 3.5 Core 745 70 Sqmm 3.5 Core 746 50 Sqmm 3.5 Core 747 35 Sqmm 3.5 Core 748 25 Sqmm 3.5 Core 749 10 Sqmm 4 Core 750 Supply Of Palm / Pin Type Copper Tin Plated Cable Sockets ( Lugs ) To The Cable Leads, Insulating With Tape 751 95 Sqmm 752 70 Sqmm 753 50 Sqmm 754 35 Sqmm 755 25 Sqmm 756 16 Sqmm 757 10 Sqmm 758 6 Sqmm 759 Supply Of Gi Box Alonwith Modular Base And Cover Plate For Modular Switches In Recess1 Or 2 Module ( 75 Mmx75 Mm ) 760 Supply Of Telephone Socket Outlet ( Modular ) 761 Supply Of Tv Antenna Socket Outlet ( Modular ) 762 Supply Of Bell Push ( Modular ) 763 Supply Of Call Bell / Buzzer Suitable Single Phase 230 V 764 Supply Of Telephone Cable Following Pair 0.5 Sqmm Fr Pvc Insulated Annealed Copper Conductor, Unarmoured 765 2 Pair 766 10 Pair 767 20 Pair 768 Supply Of Co-Axial Tv Cable Rg-6 Grade 0.7 Mm Solid Copper Conductor Pe Insulated Sheeted With Fine Tinned Copper Braid And Protected With Pvc Sheet 769 Supply Of 10 Pair Junction Boxes For Floors And Building With Krone Connectors 770 Supply Of 20 Pair Junction Boxes For Floors And Building With Krone Connectors 771 Supply Of 50 Pair Junction Boxes For Floors And Building With Krone Connectors 772 Supply Of Exhaust Fan Of Ac 230 / 250 V, 50 Hz Including Nuts & Bolts, Mounting Frame And Other Accessories.300 Mm Sweep 773 Supply Of Energy Meter ( 3 Phase ) And Other Accessories. 774 Supply Of Wall Fanof Ac 230 / 250 V, 50 Hz Including Nuts & Bolts, Mounting Frame And Other Accessories. 450 Mm Sweep 775 Supply Of Exhaust Fan Of Ac 230 / 250 V, 50 Hz Including Nuts & Bolts, Mounting Frame And Other Accessories.450 Mm Sweep 776 Supply Of Weired Decorative Mirror Light Suitable 9 Watt Led With Lamp Complete 777 Supply Of Factory Weired Integral Led Flood Light Luminaries With Die Cast Aluminium Housing Built With Driver Set Suitable For 40 To 50 Watt Confoming To Ip 65 / 66 Protection Complete. 778 Supply Of Swiches ( Modular ) 5 Amp 779 Supply Of Sockets ( Modular ) 5 Amp 780 Supply Of Pvc Conduit Pipe 25 Mm Dia 781 Supply Of Round Sheet 782 Supply Of Ceiling Rose 783 Supply Of Holder For Bulbs 784 Fixing Of Main Lt Panel 785 Fixing Of Main Em Panel 786 Fixing Of Sub Panel 787 Fixing Of Sub Em Panel 788 Fixing Of Capacitor Panel 150Kvar 789 Fixing Of Feeder Piller 790 Fixing Of Street Feeder Piller 791 Supply Of Coarse Sand 792 Supply Of Cement50 Kg 793 Supply Of Brick M150 794 Supply Of Stone Grit 20 Mm 795 Supply Of Stone Ballast 40 Mm 796 Supply Of Tor Steel 8 Mm Dia 797 Supply Of Tor Steel 10 Mm Dia 798 Supply Of Tor Steel 12 Mm Dia 799 Supply Of Tor Steel 16 Mm Dia 800 Supply Of Tor Steel 20 Mm Dia 801 Supply Of Tor Steel 25 Mm Dia 802 Supply Of Ms Fabrication For Door Window And Ventilator 803 Supply Of Water Proofing Chemical Cico Tapecrete P151 804 Supply Of Y Shaped Angle Iron Post 40X40x6 805 Supply Of Kota Stone 22 Mm Thick 806 Supply Of Vitriried Floor Tile 8 To 10 Mm Thick In 600X600 Mm Size 807 Supply Of Wall Tile Glazed / Ceramic Floor Tiles 808 Supply Of Ss Railing 304 Grade 809 Supply Of Ms Collapsible Channel 810 Supply Of Rolling Shutter With Ball Bearing 811 Supply Of Granite 812 Supply Of Cinder 813 Supply Ofchequred Tile 300X300 Mm Size 814 Supply Of Ms Gate Made Of Ms Hollow Sections 815 Supply Of Interlocking Pavers 80 Mm M30 Mpa

Key Value

Document Fees
INR 11800 /-
EMD
INR 200000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Invitation of Rates for Supply of Materials & Piece rated works (Labour Rates) at Govt. Polytechnic Kurar, Kayamganj, Farrukhabad.
Sl. No. Item Description
1Earth work in excavation in trenches for foundation pipes, cable etc in ordinary sol (Loam clay or sand) inlcuding lift upto 1.5 Mt. lead upto 30mt. and dressing of sides and rammings of bottom and disposal of surplus excavated earth as directed by the engineer.
2upto 1.50 m to 3.00 m deep
3upto 3.00 m to 4.50 m deep
4upto 4.50 m to 6.00 m deep
5Filling of carted earth
6Laying in position cement concrete of specifiedgrade including the cost of centring and shuttering-All work upto plinth level.
7in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded stone aggregate 40 mm nominal size)
8in cement concrete 1:2:4 (1 cement : 2 course sand : 4 graded stone aggregate 20 mm nominal size )
9Coarse Sand (compacted) filling in sides of foundation & floor
10Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete. (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm(4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer"s standard dilution)
11R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also excluding supply of all materials, and including labour and tools and plants etc, required for proper completion of the works.
12Ground Floor
13First Floor
14Second Floor
15As in item no. 6 above but for slabs (Using 1:1.5:3 Mix concrete).
16Ground Floor
17First Floor
18Second Floor
19As in item 6 but for thelighterbeams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete)
20Ground Floor
21First Floor
22Second Floor
23As in item 6 abovebut inR.C.C.Raft foundation and footingwithapproved stone ballast.(Using1:1.5:3Mix concrete)
24As in item 6 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20.
25Ground Floor
26First Floor
27Second Floor
28M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth includinglabour and T & P etc & excluding supply of all materials, required for proper completion of the work.
29M-150 brick work in 1:4 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth includinglabour and T & P etc & excluding supply of all materials, required for proper completion of the work.
30Laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
31Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
32Same as in item No. 11 abovebutin super-structure above plinth level up to floor two level (up to two storeys) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand)
33Ground Floor
34First Floor
35Second Floor
36Same as in item no. 14 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work.
37Ground Floor
38First Floor
39Second Floor
40Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and excluding supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level.
41Ground Floor
42First floor
43Second Floor
4415 mm cement plaster on rough side of single or half brick wall of mix : 1:3 (1 cement: 3 coarse sand)
4515 mm cement plaster in single coat on rough side of single or halfbrick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand .
46Ground Floor
47First Floor
48Second Floor
4912mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 finesand.
50Ground Floor
51First Floor
52Second Floor
53Engraving lines in the plaster of outer face well vertically & horizontally to display the surface as stone facing as directed by the Engineer-in-charge including labpur, & T & P etc. required for proper completion of the work.
54Ground Floor
55First Floor
56Second Floor
57Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
58Laying 8 to 10 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size with all colours and shades, laid on 20mm thick cement mortar 1:3 (1 cement : 3 coarse sand) finishing with cement slurry & with pigment grouting & polishing complete including supply of all labour, T & P etc. excluding the cost of materials required for proper completion the work.
59Ground Floor
60First Floor
61Second Floor
62Laying 8 to 10 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size with all colours and shades, laid on 20mm thick cement mortar 1:3 (1 cement : 3 coarse sand) finishing with cement slurry & with pigment grouting & polishing complete including supply of all labour, T & P etc. excluding the cost of materials required for proper completion the work.
63Ground Floor
64First Floor
65Second Floor
66Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
67Ground Floor
68First Floor
69Second Floor
70Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
71Ground Floor
72First Floor
73Second Floor
74Fixing of 6 mm thick approved China white / coloured glazed tiles in flooring or dado laid with 1:3 cement and approved coarse sand mortar finished and jointed with white cement slurry and pigment and polishing complete includinglabour and tool sand plants & excluding supply of all materials,etc. required for proper completion of the work.
75Ground Floor
76First Floor
77Second Floor
7825 mm thick cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12.5mm nominal size and below) by laid over base concrete finished with floating coat of neat cement (base concrete to be paid separately) including fixing of glass strips. (excluding cost of glass strips)
79Supply of flush doors commercial qualityconforming to I.S.2202 Part I (1983) including fixing of wooden cleats and stoppers
8035 mm thick
81(a) Single leaf
82(b) Double leaf
8332 mm thick
84(a) Single leaf
85Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I)
86Fixing of flush / pvc doors including fixing of wooden/pvc cleats and stoppers and includingfixing and adjustment of hinges, bolts,locks, handle, springs. Fittings to be supplied departmentally.
87Supply of factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing. 30 mm thick plain PVC door shutters
88Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing.
89M.S. Hold fast for doors and windows
90M.S. Grill
91Z-Section winodws (Openable)
92M.S. angle door chaukhat 40*40*5
93Fixing of door, windows / ventilators chaukhats in position.
94(a) Door chaukhats
95(b) Window chaukhats
96(c) Ventilator chaukhats
97Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (Inside walls)
98Ground Floor
99First Floor
100Second Floor
101Finishing walls with two coat of Acrylic Smooth exterior paint of best quality including supply of all materials labour and tool sand plants etc. required for proper completion of the work.
102Ground Floor
103First Floor
104Second Floor
105Finishing wall with water proof cement paint of approved make and quality on new wood with two coat to give an even shade including supply of all materials, labour, tools and plant etc. required for proper completion of the work. (Two Coat)
106Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work supply of all materials, labour, tools and plant etc. required for proper completion of the work. (Two Coat)
107Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth excludingcost of all materials. (Ceiling)
108Providing & Applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
109Supply of 150 mm bright finished floor stainless steel door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete.
110Supply of Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm .
111Supply of stainless steel towerbolts (barrel type) with necessary screws etc. complete
112(a) 300mm x 10mm
113(b) 250 mm x 10mm
114Supply of bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (a) 125 mm
115Providing and laying cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming toIS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
116Painting or Vanishing two coat on iron work in small areas or new wood work with one coat of ready mixed priming paint and one coat of approved superior ready mixed paint of clear synthetic varnish including supply of all materials, labour, T & P etc. required for proper completion the work. Paint to be used should confirm to the I.S.I. No. 103 1950.
117Same as item above but on new wood surface.
118Fixing panes of glass with equal or equivalent I.S.I. marked quality putty, brads and springs including supply of all materials, labour etc. complete. 3.80 to 4.70 mm thick
119Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing & excluding supply of all materials complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : Light shade pigment using white cement.
120Filling of light cinder filling under floor of toilets & other sunken roofs.
121Labour charges for wiring points for light with 1.5 sqmm.FRLSH PVC insulated single core Copper condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm.FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire and piano type switch etc. complete in all respects.
122Same as item No. (1) but for two way light Points.
123Same as item No. (1) but for fanandlight duty exhaust fan.
124Same as item No.(1) but for5amp plug point with piano type switch and socket etc.
125Addition when modular type switches etc are used in place of piono type switches etc. in various wiring points.
126Addition for light / fan points with modular type switchin place of piono type switch.
127Addition for plugpointswith modular type switchin place of piono type switch.
128Addition for Exhaust fanpointswith modular type switchin place of piono type switch.
129Wiring of submains with 2 nos. 2.5 sq.mm & with 1 no. earth wire of 1.5 sq.mm FR PVC insulated 1100 V grade single core multistrand copper conductor cable in 20 mm dia heavy duty (2mm thick) PVC conduit complete, including supply of all material, labourand T&P etc. required for proper completion of the work as directed by Engineer I/C.
130Wiring of submain 2 number 4 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.
131Wiring of submain 2 number 6 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty( 2 mm thick ) 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 4 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.
132Wiring of submain 4 number 10 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty ( 2 mm thick ) 32mm dia PVC conduitalong with two numbers 6 sqmm FRLSH PVC insulated multistranded copper conductorcable as earth contunity wire etc. complete in all respects.
133Wiring of submain 4 number 16 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty ( 2 mm thick ) 40mm dia PVC conduitalong with two numbers 10 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.
134Wiring of submain 4 number 25 sqmm . FRLSH PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty ( 2 mm thick ) 50mm dia PVC conduitalong with two numbers 16 sqmm FRLSH PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.
135Fixing and concealing of20mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material labour and T & P etc required for proper completion of work( forTelephone)
136Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. Pipe 19mm dia duly painted, complete in all respects.
137Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects.
138Fixing of hexagonal/Round G.P. fan box of approved make made up of 1.0mm thick ISI Marked G.P. sheet spot weeldeed Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screewed fitted with 300mm round zink coted M.S Bar X 12mm & brand name should be embossed.Fixing with wiring conduit laid in the R.C.C roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work.
139Supply of Ceiling Fan with fan motor of A.C Permanent insulation, capacitor rating conforming BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment. The rated voltage 220/240 volts, 50Hz, 1-ph AC the fan assemble should consists of down road blades, shackle canopies etc and with double ball bearing system. BEE 5 Star rated-1200mm sweep
140Fixingofelectronic fan regulator(Modular) 120-280 V. ISImarked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work.
141Fixing of LED Tube Light with Metal heavy dutyBox type batten Light fitting 2 x 22 watt suitable for up to 2 x 22 watt LED Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects.(CAT: AAA)
142Fixing of LED Tube Light with Metal heavy dutyBox type batten Light fitting 1 x 22 watt suitable for up to 1 x 22 watt LED Polycarbonate tube light complete including tube etc suitable for both surface & surface complete in all respects.(CAT: AAA)
143Fixing of recess/Surface mounting round 10 to 15 watt, cut out Min 125mm, Height Min 40mm, LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set, suitable for 24Hr continuous Operation,complete in all respect.(CAT: AAA)
144Fixing of single LED light wall bracket on matching M.D.F.E.G board base etc. complete in all respect.(CAT: AAA)
145Fixing of water tight oblong 10 watt LED bulhead luminaire with driverr set confirming to IP 65 and above Protection complete in all respect.(CAT: AAA)
146Fixing of surface/flush mounting distribution boards with additional metal door withot MCB complete in all respects.(CAT A)
1474 Way TPN
1486 Way TPN
1498 Way TPN
150Fixing of 6Amp to 32 Amp (10 KA)SP MCB in existing MCB, DB complete with connections as required. (CAT: A)
151Fixing and making connection of following MCBS complete in all respects as per direction and satisfaction of engineer-in-charge.(CAT: A)
15240 Amp. FP MCB(CAT: A)
15363 Amp. FP MCB(CAT: A)
154Fixing of surface/flush mounting V TPN distribution boards with additional metal door withot MCB complete in all respects.(CAT A) 4 Way V TPN
155Fixing and making connection of following MCCBS complete in all respects as per direction and satisfaction of engineer-in-charge.(CAT: A)
156100 Amp. FP MCCB(CAT: A)
157125 Amp. FP MCCB(CAT: A)
158160 Amp. FP MCCB(CAT: A)
159Fixing and making connection of following MCBS complete in all respects as per direction and satisfaction of engineer-in-charge.(CAT: A)
16040 Amp. TP MCB(CAT: A)
16163 Amp. TP MCB(CAT: A)
162Fixing of power plug with 15A/250 V flush type switch and 5 Pin 15 A/250V flush type universal socket in suitable M.S. box of 175mmx100x50mm size with phenolic laminated bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer.
163Fixing of power plug with 20A/250 V flush type switch and 5 Pin 20 A/250V flush type universal socket in suitable M.S. box including supply of all material, labor T&P etc. required for proper completion of work.
164Fixing of Single Pole MCBS Blanking Plate complete in all respects. (CAT: A)
165Fixing and making connection of following MCCBS complete in all respects as per direction and satisfaction of engineer-in-charge. 63 Amp. FP MCCB
166Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8to10SWG G.I.wire in 15mm dia G.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in
167Laying of 25mmx3mm G.I. Strip for earthing purpose as required complete in all respects.
168Fixing of two number 8 SWG G.I. wire in 15mm dia GI pipe for earthing purpose as required complete in all respects.
169Laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the
17095 sqmm3.5 core
17170 sqmm3.5 core
17250 sqmm3.5 core
17335 sqmm3.5 core
17425 sqmm3.5 core
17510 sqmm4 core
176Fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire
17795 sqmm3.5 core
17870 sqmm3.5 core
17950 sqmm3.5 core
18035 sqmm3.5 core
18125 sqmm3.5 core
18210 sqmm4 core
183Fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge.
18495 sqmm
18570 sqmm
18650 sqmm
18735 sqmm
18825 sqmm
18916 sqmm
19010 sqmm
1916 sqmm
192Fixing ofMODULAR BOXES, BASE & COVER PLATE
193Fixing of following size/modules, GI box along with modular base& cover plate for modular switches in recess etc as required. 1 or 2 Module (75mm X 75 mm)
194FIXING OFMODULAR TYPE SWITCH / SOCKET :-
195Fixing of following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required.
196Telephone socket outlet
197TV Antenna socket outlet
198Bell Push
199Fixing of call bell/ buzzer suitable single phase, 230 V etc as required.
200Laying oftelephone wire following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 2 Pair
201Drawing of co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/recessed steel/PVC conduit as required.
202Drawing telephone wire following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required.
20320 Pair
20410 Pair
205Fixing of 10 pair Junction Boxes for Floors and building with Krone connectors , with connection and punching of same
206Fixing of 20 pair Junction Boxes for Floors and building with Krone connectors , with connection and punching of same
207Fixing of 50 pair Junction Boxes for Floors and building with Krone connectors , with connection and punching of same
208Laying unplastisized rigid PVC pipe conforming to IS:13592 type A including jointing , cuttingand making good the walls & floors as per requirement. 150mm
209Supply of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required 300mm sweep.
210Fixing of energy Meter and other accessories including connections etc. complete as required 3 Phase Meter
211Erection of AC 230/250 Volts, 50 Hz Wall fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required450mm sweep.
212Supply of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required450mm sweep. (At Labs)
213Fixing of wired decorative mirror light on suiatable for 9 Watt LED with lamp complete in all respect.
214Fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 40 to 50 Watt Conforming to IP 65/66 protection complete in all respect. (CAT-AAA)
215Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b)Second layer of slurry of cement@ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm.This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
216Fixing of stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, excluding the cost of materials on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.
217Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas thatccommodates multi directional seismic movement without stress to it"s components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions.The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall confirm to ASTM 6063)Floor Joint of 100 mm gap
218Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement
219and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including verticalisplacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.)Roof Joint of 100 mm gap
220Providing and fixing of expansion joint systemelated with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimalexposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063).Wall Joint of 100 mm gap
221Fixing in position Stainless steel Grade 304 plate-1.0 mm thick as per design for expansion joints. 200 mm wide.
222Granite stone slab 18 mm thick mirror polished quarter rounded with anti skid lines in treads of staircase full length flooring over 20 mm (average) thick base laid over and jointed with cement slurry mixed with pigment to match the shade of including rubbing & polishing complete with base of cement mottar 1:4 (1 cement : 4 coarse snad) etc. complete excluding the cost of materials.
223Ground Floor
224First Floor
225Second Floor
226Fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts,ocking arrangement, stoppers, handles, including applying a priming coat of approved steel primer & excluding the cost of materials.
227Fixing Rolling Shutters of approved make of 80 × 125 mm (3" × 18 gauge) cold rolled ML Lath inter lockedthrough their eintire length and joined together at the end by locks and mountedon specially designed pipe shaft with brackets and wall bearing & excluding the cost of materials.
22840mm thick cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size and below) by laid over base concrete finished with floating coat of neat cement (base concrete to be paid separately) including fixing of glass strips. (excluding cost of glass strips)
229Fixing glass strips in joints of floors and skirting or dado add the item of laying floors flush with floor level including supply of all materials, labour, T & P etc. required for proper completion the work. (a) 37 mm wide and 3.15 mm thick
23052 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer"s specifications.but excluding the cost of materials etc. complete.
231Supply of 80mm thick Rubber Moulded cement concrete interlocking pavers block. The compressive strength of concrete pavers blocks shall not be less than 30MPa & 4.5Kg/no.
232Providing and laying of 80mm thick Rubber Moulded cement concrete interlocking pavers block. The compressive strength of concrete pavers blocks shall not be less than 30MPa & 4.5Kg/no.
233Fixing of Angle Iron Frame 40x40x6 mm in position.
234Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, G.I. barbed wire, earth work and concrete to be paid for separately)
235Mild steel or iron work in heavy sizes such as trusses built up gates, door frames, record racks, roof work gates etc. wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing.
236Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 2nd class teak wood beading 62X19 mm.
237Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : 35 mm thick shutters with ISI marked M.S. pressed butt hinges bright finished of required size
238Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) On one side only
239P/F curtain rods of 1.25mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs etc. wherever necessary complete (a) 25 mm dia.
240Fixing of G.I. Pipe(80 MM DIA) as per design & drawing As per drection of EIC
241Fabrication of angle iron door chaukhat of 40*40*6 mm
242Supply of concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metrelength, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre.
243Fixing of concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metrelength, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of Materialsshall be paid separately)
244Supply of M.S. foot rest as per standard design with 20x20mm sq bars.
245Fixing of M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars.
246Supply ofC.I. tee at the inlet and outlet of septic tank.
247Fixing C.I. tee at the inlet and outlet of septic tank.
248Supply of 75mm dia vent pipes.
249Fixing of 75mm dia vent pipes.
250Supply of 75mm dia cast iron terminal guard.
251Fixing of 75mm dia cast iron terminal guard.
252Supply ofprecast RCC manhole cover and frame of required shape and approved quality.
253M.D. -10- Circular shape 500mm internal diameter
254M.D. -2.5- Circular shape 450mm internal diameter
255Fixing in position precast RCC manhole cover and frame of required shape and approved quality.
256M.D. -10- Circular shape 500mm internal diameter
257M.D. -2.5- Circular shape 450mm internal diameter
258Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m.
259up to 1.50 m depth
260Pipes 80 mm to 300 mmdiameter
2611.50 m to 3.00 m depth
262Pipes 80 mm to 300 mmdiameter
263Opentimbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered)
264Depth not exceeding 1.5 meter
265Depth 1.5 to3.00meter
266Supply of Non pressureNP 2 class (light duty) RCC pipe with collars etc. complete.
267150 mm.dia. RCCPipes
268250 mm.dia. RCCPipes
269100 mm dia RCC Pipes
270Laying of NonpressureNP 2 class (light duty) RCC pipe with collars jointed withstiffmixtureofcement mortar in the proportion of 1:2 (1cement : 2 finesand ) includingtestingof joints etc. complete.
271150 mm.dia. RCCPipes
272250 mm.dia. RCCPipes
273100 mm dia RCC Pipes
274Laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design
275150 mm.dia. RCCPipes
276250 mm.dia. RCCPipes
277100 mm dia RCC Pipes
278Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design.
279Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).
280Extra for depth for manholes:
281Inside size 90x120cms and 90cms deep including CI cover with frame (MEDIUM duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58kg).
282Extra for depth for manholes:
283Supply of orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture"s permanent identification mark to be visible even after fixing.
284Fixing of orange colour safety footrests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
285Supply of double flanged (Screwed/Welded) centrifugally (Spun) Ductile iron pipes of class K-9 conforming to IS 8329 100mm dia Ductile iron double flanged
286Fixing & laying double flanged (Screwed/Welded) centrifugally (Spun) Ductile iron pipes of class K-9 conforming to IS 8329 100mm dia Ductile iron double flanged
287Supply of CI specials such as Bends, reducers, collars etc. including cartage, loading, unloading, taxes, excise etc. complete.
288Fixing of CI specials such as Bends, reducers, collars etc. including cartage, loading, unloading, taxes, excise etc. complete.
289Supply of push-on-joints to centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket : 100mm dia pipes
290Fixing of push-on-joints to centrifugally (Spun) Cast Iron Pipes or Ductile Iron Pipes including testing of joints and including the cost of rubber gasket : 100mm dia pipes
291Supply ofC.I. Sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately): 100mm diameter
292Fixing of C.I. Sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately): 100mm diameter
293Supply of C.I. Double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc. if required will be paid separately. a) 50mm dia
294Fixing of C.I. Double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc. if required will be paidsaperately 50mm dia
295Supply of G.I. pipes (medium) complete with G.I. fittings
29680mm nominal bore.
29765mm nominal bore.
29850mm nominal bore.
29940mm nominal bore.
30032mm nominal bore.
30125mm nominal bore.
30220mm nominal bore.
30315mm nominal bore.
304Laying, jointing, testing & commisioning ofG.I. pipes complete with G.I. fittings includingtenching and refilling etc. (external work)
30580mm nominal bore.
30665mm nominal bore.
30750mm nominal bore.
30840mm nominal bore.
30932mm nominal bore.
31025mm nominal bore.
31120mm nominal bore.
31215mm nominal bore.
313Supplying of specials for pressure pipe.
314Fixing of specials for pressure pipe.
315Supply ofgate valve (with cap complete with bolts, nuts, rubber insertion etc.
31680mm nominal bore.
31765mm nominal bore.
31850mm nominal bore.
31940mm nominal bore.
32032mm nominal bore.
32125mm nominal bore.
322Fixing of gate valve (with cap complete with bolts, nuts, rubber insertion etc.
32380mm nominal bore.
32465mm nominal bore.
32550mm nominal bore.
32640mm nominal bore.
32732mm nominal bore.
32825mm nominal bore.
329Constructing masonry Chamber 90X90X100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand ) for sluice valve, with C.I. surface box 100mm, top diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
330Constructing brick masonry chamber 600 x 600x750mm insidewithF.P.S. brickwork in cement mortar 1:4 (1 cement : 4 coarse sand) for Sluice Valve / Air Valve, with C. I. surface box 100 mmtop diameter, 160 mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slabwith 1 : 2 : 4 mix (1 cement : 2 coarsesand : 4 gradestone aggregate 20 mm nominal size); necessary excavation,foundationconcrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plasteringwithcement mortar 1 : 3 (1 cement : 3 coarsesand ) 12mmthick finished with a floatingcoatofneat cementcomplete as per standarddesign
331Supply ofFire brigade inlet with 63 MM dia instantaneous inlet complete with all necessary fittings and MS enclosure with glass door made of 18/16 SWG sheet. 4 way
332Fixing, Installation, Testing & Commissioning ofFire brigade inlet with 63 MM dia instantaneous inlet complete with all necessary fittings and MS enclosure with glass door made of 18/16 SWG sheet. 4 way
333Supply of Sluice Valve complete with flanges, gasket, nut bolts 150 mm
334Fixing, Installation, Testing & Commissioning of Sluice Valve complete with flanges, gasket, nut bolts 150 mm
335Supply of NRV complete with flanges, gasket and nut bolts. 150 mm
336Fixing, Installation, Testing & Commissioning of NRV complete with flanges, gasket and nut bolts. 150 mm
337Supply of MS Pipes conforming to IS:1239 (Medium- B class) including all fittings like anchor fasteners, brick masonry supports, couplings, bends, elbows, tees and flanges etc. welded or screwed joints as required (For Riser)
338150 mm dia
339100mm dia
340Fixing of MS Pipes conforming to IS:1239 (Medium- B class) including all fittings like anchor fasteners, brick masonry supports, couplings, bends, elbows, tees and flanges etc. welded or screwed joints as required, cutting holes and chases in brick or RCC walls and making good complete. (For Riser)
341150 mm dia
342100mm dia
343Supply of Manual Swing Type First aid Fire Hose Reel conforming to IS: 444 complete with all other necessary fixing accessories.
344Fixing, installation, testing and commissioning of Manual Swing Type First aid Fire Hose Reel conforming to IS: 444 complete with all other necessary fixing accessories.
345Supply of Fire Man Axe.
346Fixing of Fire Man Axe.
347Supply of Singal Headed Hydrant Landing Valve comprising of 80 mm dia flanged Bend 63 mm dia, with cap and chain conforming to IS:5290(Make : Newage/Minimax/Safex/Firex)
348Fixing, Installation, Testing & Commissioning of Singal Headed Hydrant Landing Valve comprising of 80 mm dia flanged Bend 63 mm dia, with cap and chain conforming to IS:5290(Make : Newage/Minimax/Safex/Firex)
349Supply of RRL Hose Pipe 63 mm dia × 15 Mtr. Long with GM Coupling conforming to IS : 636(Make - Newage/Jayshree/CRC)
350Fixing, Installation, Testing & Commissioning of RRL Hose Pipe 63 mm dia × 15 Mtr. Long with GM Coupling conforming to IS : 636(Make - Newage/Jayshree/CRC)
351Supply of Short Branch Pipe as per IS:903(Make : Newage/Safex/Firex)
352Fixing, Installation, Testing & Commissioning of Short Branch Pipe as per IS:903(Make : Newage/Safex/Firex)
353Supply of Butterfly Valve complete with flanges, gasket, nut bolts 100 mm
354Fixing, Installation, Testing & Commissioning of Butterfly Valve complete with flanges, gasket, nut bolts 100 mm
355Supply of Hose Cabinet Box of 18 SWG M.S.Sheet with glass to accommodate Hose Reel Drum with Ruber Pipe with Nozzle. 2 Nos. RRL Hose and 1 No. Branch Pipe with Nozzle
356Fixing, Installation, Testing & Commissioning of Hose Cabinet Box of 18 SWG M.S.Sheet with glass to accommodate Hose Reel Drum with Ruber Pipe with Nozzle. 2 Nos. RRL Hose and 1 No. Branch Pipe with Nozzle
357Supply of Air cushion Tank (2000x1000)mm.
358Fixing, Installation, Testing & Commissioning of Air cushion Tank (2000x1000)mm.
359Supply of Air Release Valve.
360Fixing, Installation, Testing & Commissioning of Air Release Valve.
361Supply of NRV complete with flanges, gasket and nut bolts. 100 mm
362Fixing, Installation, Testing & Commissioning of NRV complete with flanges, gasket and nut bolts.
363Supply of Pressure Gauge with gauge cock
364Fixing, Installation, Testing & Commissioning of Pressure Gauge with gauge cock
365Supply of electrical motor driven fire pump suitable for automatic operation consisting of following : (Terrace Pump)(Make : Kirloskar/Mather+Platt) (a) Horozontally mounted, split casing, Centrifugal fire pump complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 30 meter at the highest and farthest outlet at the specified flow cmplete with necessary strainers, pressure gauge including bypass arrangement for periodic testing of the working of the pumpset with required length and size of medium class GI pipe and control valves for proper completion of work.The pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head.The pump shall be provided with Mechanical seals. The impeller shall be enclosed type and accurately blanced dynamically.The pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel. (b) Squirrel cage, TEFC induction motor suitable for 415 V, 3 phase having IP 55 protection and class "B" insulation for the above pump and flexible coupling with the pump.The motor shall b rated for continuous duty and shall have HP rating necessary to drive th pump at 150% of it"s rated discharge at 65% of rated head. © Common bed plate of fabricated mild steel channel or cast iron type. (d) Suitable cement concrete pump foundation and vibration clamping arrangement as required with foundation bolts, anti vibration pads, washers etc.(e) Pressure switch for automatic operation of motor including necessary wiring upto control panel. (f) Electrical Control panel with starter, 3 Pole motor protection category current limiting type MCCB, indicating light, ammeter, voltmeter, selector switches, CT"s protective fuses, single phasing protection, dry suction cut off etc as requrd as per standard details.Discharge :450 liter per minute Head : 35 meter
366Installation, testing and commisioning of electrical motor driven fire pump suitable for automatic operation consisting of following : (Terrace Pump)(Make : Kirloskar/Mather+Platt) (a) Horozontally mounted, split casing, Centrifugal fire pump complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 30 meter at the highest and farthest outlet at the specified flow cmplete with necessary strainers, pressure gauge including bypass arrangement for periodic testing of the working of the pumpset with required length and size of medium class GI pipe and control valves for proper completion of work.The pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head.The pump shall be provided with Mechanical seals. The impeller shall be enclosed type and accurately blanced dynamically.The pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel. (b) Squirrel cage, TEFC induction motor suitable for 415 V, 3 phase having IP 55 protection and class "B" insulation for the above pump and flexible coupling with the pump.The motor shall b rated for continuous duty and shall have HP rating necessary to drive th pump at 150% of it"s rated discharge at 65% of rated head. © Common bed plate of fabricated mild steel channel or cast iron type. (d) Suitable cement concrete pump foundation and vibration clamping arrangement as required with foundation bolts, anti vibration pads, washers etc.(e) Pressure switch for automatic operation of motor including necessary wiring upto control panel. (f) Electrical Control panel with starter, 3 Pole motor protection category current limiting type MCCB, indicating light, ammeter, voltmeter, selector switches, CT"s protective fuses, single phasing protection, dry suction cut off etc as requrd as per standard details.Discharge :450 liter per minute Head : 35 meter
367(a) Horozontally mounted, split casing, Centrifugal fire pump complete for delivery of under mentioned discharge against desired mentioned head so as to ensure a minimum pressure of 30 meter at the highest and farthest outlet at the specified flow cmplete with necessary strainers, pressure gauge including bypass arrangement for periodic testing of the working of the pumpset with required length and size of medium class GI pipe and control valves for proper completion of work.The pump shall be capable of giving 150% of rated discharge at head not less than 65% of rated head.The pump shall be provided with Mechanical seals. The impeller shall be enclosed type and accurately blanced dynamically.The pump casing shall be of cast iron, impeller shall be of bronze and shaft shall be of stainless steel.
368Fixing & placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license].
369Supply of halon free portable fire Extinguishers as described below:
3704.5 kg carbon dioxide extinguisher, IS marked, with high pressure discharge tube, horn, control valve, CCE approved cylinder
3716 kg Mono Ammonium Phosphate (ABC) type cartridge operated extinguishers
3729 kg Mono Ammonium Phosphate (ABC) type cartridge operated extinguishers
373Providing, fixing, testing and commissioning of 50 Litres (trolley mounted) Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked TAC approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and confoming to IS:910 .
374Providing, fixing, testing and commissioning of CO2 type Fire Extinguisher of capacity 22.5 kg filled with Co2 Gas as per IS 15222 with controll discharge mechanism fitted with Hose, Horn & TROLLEYconfirms to IS 2878 bearing ISI mark. Co2 Cylinder as per IS 7285
375Fixing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below:
376Supply of Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate size for fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete.
377Fixing of Fire related signages printed on photoluminescent U1000 aluminium sheet of 1.0 mm (+-10%) containing Lumigen II as base chemical, covered under UV stablized coating and of appropriate sizeincluding fixing on wall, door, ceiling etc. with proper clamps, hangers, cleats, anchor fasteners etc. complete in all respects as directed by Engineer-in-charge.
378Supply ofCI cover with frame LIGHT WEIGHT complete as perdesign size 600x600 mm
379Supply ofCI cover with frame LIGHT WEIGHT complete as perdesign size 900x900 mm
380Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level.Drilling of 250 mm dia bore hole manually.
381Supply of unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818,fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.150 mm nominal size dia
382Assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.150 mm nominal size dia
383Supply of stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
384Supply of gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
385Supply of coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
386Filling, spreading & leveling coarse sand, gravels & stone boulders of size range 1.5 mm to 20 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.
387Transportation Charges of drilling equipment including assembly and other material as required.
388Drilling of 675 mm. dia by rotary machine
389Supply of 350 mm. dia housing pipe (8 mm. thick)
390Laying of 350 mm. dia housing pipe (8 mm. thick)
391Supply of 200 mm. dia blind pipe (8 mm. thick)
392Laying of 200 mm. dia blind pipe (8 mm. thick)
393Supply of 200 mm. dia slotted pipe (8 mm. thick)
394Laying of 200 mm. dia slotted pipe (8 mm. thick)
395Supply of 350 mm. dia Socket
396Fixing of 350 mm. dia Socket
397Supply of 200 mm. dia Socket
398Fixing of 200 mm. dia Socket
399Supply of 200 mm. dia Bail plug
400Fixing of 200 mm. dia Bail plug
401Supply of 350 mm. dia well cap
402Fixing of 350 mm. dia well cap
403Supply of 350x200 mm. dia reducer.
404Fixing of 350x200 mm. dia reducer.
405Supply of 350 mm. dia housing clamp
406Fixing of 350 mm. dia housing clamp
407Supply of pee gravel 2 mm. 4 mm. in side of bore after lower and development as required as per direction of E/I.
408Filling of pee gravel 2 mm. 4 mm. in side of bore after lower and development as required as per direction of E/I.
409Development by air compressor including Transportation.
410Development by O.P. Unit including Transportation.
411Supply of 7.5 HP KSB make submersible pump set model BPD 302/4+UAMI 150/6/22-203 (S/D) suitable for tube well capable of pumping clear and cold water free from chemical and directly coupled with KSB electric moter operating of 415 volt suitable for 3 phase 50 cycle A.C. Supply of following duty condition 7.5 HP 6 stage pipe.A - Discharge of water in LPM 860 Approx size of discharge outlet in 80 mm.B - Total Head of pump set 45 m.
412Supply of finolex or equivalent ISI marked submersible copper cable of size 2x3x2.5 sq. mm.
413Fixing of finolex or equivalent ISI marked submersible copper cable of size 2x3x2.5 sq. mm.
414Supply of control panel cubical type wall mounted vermin proof with internal wiring duly enameled painted and mechanically finished having L&T of qul. Male switch fuse unit with HRC fuses, Ameter, Boltmeter, Selector switch, phase indicating lamp with bulbs, instrument fuses, power capcitor single phase preventor etc. complete set with supply of Jyoti or eq. Air break Star- Delta motro starter suitable for above submersible pump set.
415Supply of 80mm dia M.S. column pipe of class "C" both and socketed with heavy sockets in 3/6 meter length and one end flanged complete with interlocking arrangements.
416Lowering of 80mm dia M.S. column pipe of class "C" both and socketed with heavy sockets in 3/6 meter length and one end flanged complete with interlocking arrangements.
417Supply of 80mm dia M.S. column pipe clamps with nut, bolts, packing etc.
418Lowering of 80mm dia M.S. column pipe clamps with nut, bolts, packing etc.
419Supply of 80mm dia C.I. double flanged ISI mark reflex valve of updadhya or equ. Make.
420Fixing ofC.I. double flanged reflex valve
421Supply of 80mm dia C.I. double flanged ISI mark sluice valve with hand wheel of upadhya or equ. Make.
422Supply of 100 mm dia C.I. double flanged ISI mark sluice valve with hand wheel of upadhya or equ. Make.
423Supply of 150mm dia C.I. double flanged ISI mark sluice valve with hand wheel of upadhya or equ. Make.
424Fixing of 80/100/150 mm dia C.I. double flanged ISI mark sluice valve with hand wheel
425Supply of C.I. double flanged bend of 80mm dia
426Fixing of C.I. double flanged bend of 80mm dia i/c cost of labour.
427Supply of 80mm dia C.I. tee heavy quality i/c cost of material.
428Fixing of 80mm dia C.I. tee heavy quality
429Supply of Guru/Fibing or equivalent make pressure gauge.
430Fixing of pressure gauge.
431Erection & commissioning of pumping plants complete along with electric wiring.
432Supply of steel wire rope of 1/2" size
433Fixing of steel wire rope of 1/2" size
434S/B of 600mm x 600 mm x 6.0 mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead on one no. 8 to 10 SWG GI wite in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. , pipe and G.I. wire will be extra) 30 cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal. coke and salt at least 150mm thick alround etc. as per directions of E/I complete in all respects as per drawing.
435S/F of one number 8 to 6 SWG G.I. wire in 15mm dia G.I. Pipe for earthing, laid in ground or in wall duly concealed includingn the cost of cement, sand labour. T&P other material required for proper completion of the work as directed at site.
436S/F of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 volts grade16 sqmm x 4 core
437Fixing of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 volts grade at a depth of 750mmbelow ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top.On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by E/I complete in all respects The armoring of the cable shall be properly connected with the earth conductor by clamps etc.16 sqmm x 4 core
438Supply of 500 KVA. 11/0.433 KV, 3Phase, 50Hz, Dyn 11, Oil type, ( UPPCL approved make) copper wound transformer with OFF load tap changing arrangement on HV side in steps of +/- 2.50%, +/- 5% & - 7.5% , having cable end boxes on HV sideand 800 Amp. bus trunking arrangement on LV side complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 2026 (Part 1 to Part 5) & as per specification attached complete in all respects as required at site.
439Installation, testing and commissioning of 500 KVA. 11/0.433 KV, 3Phase, 50Hz, Dyn 11, Oil type, ( UPPCL approved make) copper wound transformer with OFF load tap changing arrangement on HV side in steps of +/- 2.50%, +/- 5% & - 7.5% , having cable end boxes on HV sideand 800 Amp. bus trunking arrangement on LV side complete with all accessories i/c first filling of filtered dehydrated oil and confirming to IS 2026 (Part 1 to Part 5) & as per specification attached complete in all respects as required at site.
440Supply of 3 core standered aluminium conduktor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables confirming to I.S. 7098(Part-II with latest amendments) 11 KV grade 150sq. mm 3 Core
441Laying of 3 core standered aluminium conduktor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables confirming to I.S. 7098(Part-II with latest amendments) 11 KV grade at a depht of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks in sides and on the top put across. Thearmouring of cable shall be properly connected with earth condutor by clamps etc.150sq. mm 3 Core
442Supply of 3 core 240Sq.mm. XLPE aluminium conductor cable of 11 kV grage as required.
443Making indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for 3 core 240Sq.mm. XLPE aluminium conductor cable of 11 kV grage as required.
444Making outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for 3 core 240 Sq.mm. XLPE aluminium conductor cable of 11 kV grage as required.
445Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8 SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing.
446Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8to10SWG G.I.wire in 15mm diaG.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects.
447Supply and burying of 600mm X 600mm X 3 mm copper Plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I pipe and funnel for watering and one earthing lead ofone no. 8SWG copper wire in 15 mm dia G.I pipe up to switch board ( from appron to switch board the cost of G.I pipe and copper wire will be extra) 30 cm square C.I frame with hinged cover masonry housingalternate layers of charcoal / coke and salt atleast 150mm thick alround etc. as per directions of Engineer in charge complete in all respects.
448Supply and laying of 32mm x 6mm G.I. strip from earth electrode directly in the ground as required complete in all respects.
449Supply and Laying of 32mm X 6 mm Copper strip from earth electrode directly in the ground as required complete in all respects..
450Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respects.
451Supply and fixing of one number 8 SWG G.I wire in 15mm dia. G.I pipe for earthing laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site.
452Supply of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade
453300 sqmm3.5 core
454185 sqmm3.5 core
455150 sqmm3.5 core
45635 sqmm3.5 core
45725 sqmm3.5 core
45816 sqmm4 core
45910 sqmm4 core
46016 sqmm2 core
46110 sqmm2 core
4626 sqmm2 core
463Laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. From 6 sqmm 2 core to 300 sqmm3.5 core
464Supply of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete
465300 sqmm3.5 core
466185 sqmm3.5 core
467150 sqmm3.5 core
46835 sqmm3.5 core
46925 sqmm3.5 core
47016 sqmm4 core
47110 sqmm4 core
47216 sqmm2 core
47310 sqmm2 core
4746 sqmm2 core
475Fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per direction of EIC. From 6 sqmm 2 core to 300 sqmm3.5 core
476Supply of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape
477300 sqmm
478185 sqmm
479150 sqmm
48095 sqmm
48170 sqmm
48235 sqmm
48325 sqmm
48416 sqmm
48510 sqmm
4866 sqmm
4874 sqmm
488Fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. From 4 sqmmto 300 sqmm
489Supply of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12 mm thik) having 3mm thikness with Single arm bracket (1 Mtr length) including the cost of foundation bolts, Required T&P complete in all respect.
490Fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12 mm thik) having 3mm thikness with Single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P complete in all respect.
491Supply of LED street light fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 watt. Confirming to IP 66 and above protection complete in all respect.
492Fixing of LED street light fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 watt. Confirming to IP 66 and above protection complete in all respect.
493Supply of 6 Amp to 32 Amp DP MCB (10KA) (C curve) for poles
494Fixing of 6 Amp to 32 Amp DP MCB (10KA) (C curve) for poles
495Supply of decorative 40 to 45 Watt LED Post top indirect light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to IP 65 and above protection complete in all respect.
496Fixing of decorative 40 to 45 Watt LED Post top indirect light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to IP 65 and above protection complete in all respect.
497Supply offollowing capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contractors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN complete in all respect.25 Amp SPN
498Fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contractors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN complete in all respect.25 Amp SPN
499Supply of Bakelite sheet 3 mm thick of suitable size & connector
500Fixing of Bakelite sheet 3 mm thick of suitable size & connector
501Supply of M.S. pipe (Class "B"- IS : 1239) pole suitable for fixing 70 watt. HPSV post top including 4 pole cable junction box with 5 Amp. rewireablefuse fitting and 5 Amp. switch on laminated cover and M.S. box complete with water tight cover and 450x450x450mm base above ground and 2x4sqmm Aluminium wire from cable box to lamp for connection including painting the pole on primer coats and necessary reducers on thetop of pole for fixing of post top lantern. 65mm dia 4m long (3m above ground and 1 m below ground).
502Fixing of M.S. pipe (Class "B"- IS : 1239) pole suitable for fixing 70 watt. HPSV post top including 4 pole cable junction box with 5 Amp. rewireablefuse fitting and 5 Amp. switch on laminated cover and M.S. box complete with water tight cover includingMasonary/PCC (1:3:6) work for erecting the pole and 450x450x450mm base above ground and 2x4sqmm Aluminium wire from cable box to lamp for connection including painting the poleby an approved shade on primer coats and necessary reducers on thetop of pole for fixing of post top lantern.The work shall be complete as required up to the satisfaction of Engg.-in-Charge.65mm dia 4m long (3m above ground and 1 m below ground).
503Making of following size of Cable Chamber made of 230 mm thick brick work in cement mortar (1 cement : 6 sand) with PCC 100 mm thick PCC base plastering of inner and outer surface with cement mortar including providing of Heavy Duty C.I Cover complete with digging, refilling and removal of surplus soil complete as required. material cost will be paid saperately.900 mm x 900 mmx 1000 mm deep
504Supply of MV danger notice plate of 200 mm x 150 mm made of mild steel at least 2mmthick &vitreousenamelledwhiteon bothsides and withinscription insignalred colouronfront side as required.
505Supply of HT danger notice plate 250 mm x 200 mm made of mild steel at least 2mmthick &vitreousenamelledwhiteon bothsides and withinscription insignalred colouronfront side as required.
506Fixing of MV / HT danger notice plate 250 mm x 200 mm made of mild steel at least 2mmthick &vitreousenamelledwhiteon bothsides and withinscription insignalred colouronfront side as required.
507Supplying of Fire buckets, round bottom made of G.I. Sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-charge.
508Fixing of Fire buckets, round bottom made of G.I. Sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-charge.
509Supply of 1800 mm x 900 mm X 12 mm thick chequered rubber matting of tested quality
510Layingof 1800 mm x 900 mm X 12 mm thick chequered rubber matting of tested quality
511Supply of danger board fabricated from 10 gauge MS sheet as per IE Rules
512Fixing of danger board fabricated from 10 gauge MS sheet as per IE Rules
513Supply of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board or soft board.
514Fixing of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board or soft board with supply of all labour T & Pfor proper completion of work.
515Supply of fire extinguishers, ABC Type 4.00 kg. capacity(ISI Marked IS : 15683 & TAC approved)complete with initial charges and wall bracket,
516Supply of CO2 typefire extinguishers, 4.50 kg. capacity(ISI Marked IS : 2878 & TAC approved)complete with initial charges and wall bracket,
517Fixing of fire extinguishers, ABC Type 4.00 kg. & CO2 type 4.5 kg. capacity complete with initial charges and wall bracket, along with supply of all labour for proper completion of work.
518Supply of water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/ Hindware/ Seabird/ Orient (Coral) with all fittings and fixtures complete.White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests
519Fixing of water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/ Hindware/ Seabird/ Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests
520Supply of white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, Parryware/ Hindware/ Seabrid /Orient (Coral) with all fittings and fixtures complete.W.C. pan with ISI marked black solid plastic seat and lid
521Fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, Parryware/ Hindware/ Seabrid /Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lid
522Supply of white vitreous china extended wall mounting water closet of size 780x370x690mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
523Fixing of white vitreous china extended wall mounting water closet of size 780x370x690mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
524Supply of white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern.
525a)White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
526b)White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISi marked
527Fixing of white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required.
528a)White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
529b)White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISi marked
530Supply of P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
531Semi rigid pipe
53232 mm dia
53340 mm dia
534Fixing of P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
535Semi rigid pipe
53632 mm dia
53740 mm dia
538Supply of 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
539Fixing of 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
540Supply of Stainless Steel AISI 304(18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40mm including painting of fittings and brackets, Kitchen sink with drain board Size 510x1040 mm bowl depth 250mm
541Fixing of Stainless Steel AISI 304(18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherrerever required.Kitchen sink with drain board Size 510x1040 mm bowl depth 250mm
542Supply of white vitreous china flat back half stall urinal of size 580*380*350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings.
543Range of Three half stall urinals with 10 litre PV.C. automatic flushing cistern.
544Range of two half stall urinals with 5 litre PV.C. automatic flushing cistern.
545Range of Single half stall urinals with 5 litre PV.C. automatic flushing cistern.
546Fixing white vitreous china flat back half stall urinal of size 580*380*350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in D.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required:
547Range of Three half stall urinals with 10 litre PV.C. automatic flushing cistern.
548Range of two half stall urinals with 5 litre PV.C. automatic flushing cistern.
549Range of Single half stall urinals with 5 litre PV.C. automatic flushing cistern.
550Fixing of stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade
551Supply of unplasticised PVC connection pipe with brass unions
55245 cm length
55315 mm nominal bore
554Fixing of unplasticised PVC connection pipe with brass unions
55545 cm length
55615 mm nominal bore
557Supply of C.P. brass bib cock of approved quality conforming to IS:8931 a) 15 mm nominal bore
558Fixing of C.P. brass bib cock of approved quality conforming to IS:8931V a) 15 mm nominal bore
559Supply of C.P. brass long body bib cock of approved quality conforming to IS standards andweighing not less than 690 gms.a) 15 mm nominal bore
560Fixing of C.P. brass long body bib cock of approved quality conforming to IS standards andweighing not less than 690 gms.a) 15 mm nominal bore
561Supply of C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931a) 15 mm nominal bore
562Fixing of C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931a) 15 mm nominal bore
563Supply of C.P. brass shower rose with 15 or 20mm inlet 150 mm diameter
564Fixing of C.P. brass shower rose with 15 or 20mm inlet150 mm diameter
565Supply of C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: 150 mm diameter
566Fixing of C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: 150 mm diameter
567Supply of PTMT Bottle Trap for Wash basin and sink.Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms
568Fixing of PTMT Bottle Trap for Wash basin and sink.Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms
569Supply of PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
570Fixing of PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.
571Supply of PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
572Fixing of PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
573Supply of unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws
574110mm
57590mm
576Fixing of unplasticised-PVC pipe clips of approved design to unplasticised-PVC pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
577110mm
57890mm
579Laying of cement concrete 1:5:10(1 cement : 5 coarse sand : 10 graded stone aggregate 20mm nominal size)around P.V.C Soil and waste pipe including bed concrete as per standard design(embedded in the flooring / ground)
580100 /75 mm dia
581Supply of wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A110 mm
582Fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm
583Supply of wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592.
584Bend 87.5 degree
585110 mm Bend
586Shoe (Plain) 110 mm Shoe
587Fixing of wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
588Bend 87.5 degree
589110 mm Bend
590Shoe (Plain) 110 mm Shoe
591Supply of inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
592Fixing of the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
593Supply of unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length. 110 mm
594Fixing of unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm
595Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.
596Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.
59720mm dia nominal outer dia pipes
59825mm dia nominal outer dia pipes
59932mm dia nominal outer dia pipes
600Fixing of Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.
601Concealed work including cutting chases and making good the walls etc.
60220mm dia nominal outer dia pipes
60325mm dia nominal outer dia pipes
60432mm dia nominal outer dia pipes
605Supply of GI pipes complete with GI fittings and clamps.
60615mm dianominal bore
60720mm dianominal bore
60825mm dia nominal bore
60932mm dia nominal bore
61040mm dia nominal bore
61150mm dia nominal bore
61265mm dia nominal bore
613Fixing of GI pipes complete with GI fittings and clamps, including cutting and making good walls etc. (internal work). Internal work-Exposed on wall
61415mm dianominal bore
61520mm dianominal bore
61625mm dia nominal bore
61732mm dia nominal bore
61840mm dia nominal bore
61950mm dia nominal bore
62065mm dia nominal bore
621Painting of GI pipes and fittings with SYNTHETIC enamel paint over a ready mixed priming coat, both of approved quality for new work.
62215mm dia nominal bore
62320mm dia nominal bore
62425mm dia nominal bore
62532mm dia nominal bore
62640mm dia nominal bore
62750mm dia nominal bore
62865mm dia nominal bore
629Supply of GI Union in GI pipes
63015mm dia nominal bore
63120mm dia nominal bore
63225mm dia nominal bore
63332mm dia nominal bore
63440mm dia nominal bore
63550mm dia nominal bore
63665mm dia nominal bore
637Fixing of GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work).
63815mm dia nominal bore
63920mm dia nominal bore
64025mm dia nominal bore
64132mm dia nominal bore
64240mm dia nominal bore
64350mm dia nominal bore
64465mm dia nominal bore
645Supply of gun metal gate valve with wheel of approved quality.
64625mm dia nominal bore
64732mm dia nominal bore
64840mm dia nominal bore
64950mm dia nominal bore
65065mm dia nominal bore
651Fixing of gun metal gate valve with wheel of approved quality.
65225mm dia nominal bore
65332mm dia nominal bore
65440mm dia nominal bore
65550mm dia nominal bore
65665mm dia nominal bore
657Supply of brass stop cock of approved quality.
658b) 20 mm nominal bore
659Fixing of brass stop cock of approved quality.
660b) 20 mm nominal bore
661Supply of terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank. [Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license].
662Fixing & placing of terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank. [Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license].
663Supply of glazed stoneware pipes grade "A"100mm dia SW pipe
664Laying and jointing glazed stoneware pipes grade "A" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.100mm dia SW pipe
665Laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all roundS.W. pipes including bed concrete as per standard design 100mm dia SW pipe
666Supply of square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm size P type
667Fixing of square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design150 x 100 mm size P type
668Supply of floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B (i) Double socketed pipes.
669a) 110mm dia P.V.C. pipe
670b) 90mm dia P.V.C. pipe
671Fixing of floor and wall face Ringfit UPVC ASTRAL ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes.
672a) 110mm dia P.V.C. pipe
673b) 90mm dia P.V.C. pipe
674Supply of UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) P-Trap type Floor Trap 110 x 90mm
675Fixing of UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) P-Trap type Floor Trap 110 x 90mm
676Supply of clean out plug (Astral)
677Fixing of clean out plug (Astral)
678Supply ofterminal guard.
679a) 110mm
680b) 90mm
681fixing of terminal guard.
682a) 110mm
683b) 90mm
684Supply of wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes.
685110mm bend
68690 mm bend
687110mm Coupler
68890mmCoupler
689110x110x110 mm Single tee with door
69090x90x90 mm Single tee with door
691Fixing of wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion.
692110mm bend
69390 mm bend
694110mm Coupler
69590mmCoupler
696110x110x110 mm Single tee with door
69790x90x90 mm Single tee with door
698SUPPLY OF 1.50 SQMM FRLSH PVC INSULATED SINGLE CORE COPPER CONDUCTOR CABLE
699SUPPLY OF 2.50 SQMM FRLSH PVC INSULATED 1100 V SINGLE CORE MULTISTRAND COPPER CONDUCTOR CABLE
700SUPPLY OF 4.00 SQMM FRLSH PVC INSULATED 1100 V SINGLE CORE MULTISTRAND COPPER CONDUCTOR CABLE
701SUPPLY OF 6.00 SQMM FRLSH PVC INSULATED 1100 V SINGLE CORE MULTISTRAND COPPER CONDUCTOR CABLE
702SUPPLY OF 10 SQMM FRLSH PVC INSULATED 1100 V SINGLE CORE MULTISTRAND COPPER CONDUCTOR CABLE
703SUPPLY OF 16 SQMM FRLSH PVC INSULATED 1100 V SINGLE CORE MULTISTRAND COPPER CONDUCTOR CABLE
704SUPPLY OF 25 SQMM FRLSH PVC INSULATED 1100 V SINGLE CORE MULTISTRAND COPPER CONDUCTOR CABLE
705SUPPLY OF HEXAGONAL/ROUND GP FAN BOX OF APPROVED MAKE MADE UP OF 1 MM THICK ISI MARKED GP SHEET SPOT WELDED FOUR TO EIGHT HOLES OF 25.4 MM FOR PIPE ENTRY OF THE BOX DULY SCREEWED FITTED WITH 300 MM ROUND ZINK COATED MS BAR x 12 MM.
706SUPPLY OF CEILING FAN WITH FAN MOTOR OF AC PERMANENT INSULATION, CAPACITOR RATING CONFORMING TO BEE 5 STAR. THE RATRD VOLTAGE220/240 VOLTS, 50 Hz, SINGLE PHASE, AC THE FAN ASSEMBLE SHOULD CONSISTS OF DOWN ROAD BLADES, SHACKLE CANOPIES WITH DOUBLE BALL BEARING SYSTEM – 1200 MM SWEEP
707SUPPLY OF ELECTRONIC FAN REGULATOR (MODULAR) 120- 280 V ISI MARKED
708SUPPLY OF LED TUBE LIGHT WITH METAL HEAVY DUTY BOX TYPE BATTEN LIGHT FITTING 2x 22 WATT SUITABLE FOR 2x22 WATT POLYCARBONATE TUBE LIGHT INCLUDING TUBE ETC SUITABLE FOR BOTH SURFACE.
709SUPPLY OF LED TUBE LIGHT WITH METAL HEAVY DUTY BOX TYPE BATTEN LIGHT FITTING 1x 22 WATT SUITABLE FOR 1x22 WATT POLYCARBONATE TUBE LIGHT INCLUDING TUBE ETC SUITABLE FOR BOTH SURFACE.
710SUPPLY OF RECESS/SURFACE MOUNTING ROUND 10 TO 15 WATT, CUT OUT 125 MM, HEIGHT MIN 40 MM, LED DOWNLIGHTER HAVING POWDER COATED DIE CAST ALUMINIUM HOUSING WITH HEAT SINK, DIFFUSER / REFLECTOR AND DRIVER SET, SUITABLE FOR 24 Hr CONTINUOUSOPERATION
711SUPPLY OF SINGLE LED LIGHT WALL BRACKET ON MATCHING MDFEG BOARD BASE
712WATER TIGHT OBLONG 10 WATT LED BULKHEAD LUMINERY WITH DRIVER SET CONFORMING TO IP 65 AND ABOVE PROTECTION COMPLETE.
713SUPPLY OF SURFACE / FLUSH MOUNTING DISTRIBUTION BOARDS WITH ADDITIONAL METAL DOOR WITHOUT MCB COMPLETE. (CAT A)
7144 WAY TPN
7156 WAY TPN
7168 WAY TPN
717SUPPLY OF 6 AMP TO 32 AMP (10 KA) SP MCB (CAT A)
718SUPPLY OF FOLLOWING MCBS
71940 AMP. FP MCB (CAT A)
72063 AMP. FP MCB (CAT A)
72140 AMP. TP MCB (CAT A)
72263 AMP. TP MCB (CAT A)
723SUPPLY OF SURFACE / FLUSH MOUNTING V TPN DISTRIBUTION BOARDS WITH ADDITIONAL METAL DOOR WITHOUT MCB COMPLETE. 4 WAY V TPN
724SUPPLY OF FOLLOWING MCCBS
72563 AMP. FP MCCB (CAT A)
726100 AMP. FP MCCB (CAT A)
727125 AMP. FP MCCB (CAT A)
728160 AMP. FP MCCB (CAT A)
729SUPPLY OF POWER PLUG WITH 15 A / 250 V FLUSH TYPE SWITCH AND 5 PIN 15 A /250 V FLUSH TYPE UNIVERSAL SOCKET IN SUITABLE MS BOX 175MMx100MMx50MM SIZE (MODULAR)
730SUPPLY OF SINGLE POLE MCBS BLANKING PLATE COMPLETE
731SUPPLY OF GI PLATE FOR EARTHING SIZE 600 MM x 600MM x 6 MM
732SUPPLY OF GI PIPE 20 MM DIA
733SUPPLY OF GI WIRE 8 TO 10 SWG
734SUPPLY OF CI FRAME (30 SQCM) WITH HINGED COVER
735SUPPLY OF GI STRIP FOR EARTHING PURPOSE 25 MMx 3 MM
736SUPPLY OF ALUMINIUM CONDUCTOR PVC INSULATED ARMOURED, SERVED, SHEETED CABLE 1000 VOLTS
73795 SQMM 3.5 CORE
73870 SQMM 3.5 CORE
73950 SQMM 3.5 CORE
74035 SQMM 3.5 CORE
74125 SQMM 3.5 CORE
74210 SQMM 4 CORE
743SUPPLY OF BRASS NICKLE PLATED COMPRESSION GLAND FOR PVC INSULATED AND ARMOURED SERVED SHEETED UNDERGROUND CABLE INCLUDING RUBBER RING
74495 SQMM 3.5 CORE
74570 SQMM 3.5 CORE
74650 SQMM 3.5 CORE
74735 SQMM 3.5 CORE
74825 SQMM 3.5 CORE
74910 SQMM 4 CORE
750SUPPLY OF PALM / PIN TYPE COPPER TIN PLATED CABLE SOCKETS (LUGS) TO THE CABLE LEADS, INSULATING WITH TAPE
75195 SQMM
75270 SQMM
75350 SQMM
75435 SQMM
75525 SQMM
75616 SQMM
75710 SQMM
7586 SQMM
759SUPPLY OF GI BOX ALONWITH MODULAR BASE AND COVER PLATE FOR MODULAR SWITCHES IN RECESS1 OR 2 MODULE (75 MMx75 MM)
760SUPPLY OF TELEPHONE SOCKET OUTLET (MODULAR)
761SUPPLY OF TV ANTENNA SOCKET OUTLET (MODULAR)
762SUPPLY OF BELL PUSH (MODULAR)
763SUPPLY OF CALL BELL / BUZZER SUITABLE SINGLE PHASE 230 V
764SUPPLY OF TELEPHONE CABLE FOLLOWING PAIR 0.5 SQMM FR PVC INSULATED ANNEALED COPPER CONDUCTOR, UNARMOURED
7652 PAIR
76610 PAIR
76720 PAIR
768SUPPLY OF CO-AXIAL TV CABLE RG-6 GRADE 0.7 MM SOLID COPPER CONDUCTOR PE INSULATED SHEETED WITH FINE TINNED COPPER BRAID AND PROTECTED WITH PVC SHEET
769SUPPLY OF 10 PAIR JUNCTION BOXES FOR FLOORS AND BUILDING WITH KRONE CONNECTORS
770SUPPLY OF 20 PAIR JUNCTION BOXES FOR FLOORS AND BUILDING WITH KRONE CONNECTORS
771SUPPLY OF 50 PAIR JUNCTION BOXES FOR FLOORS AND BUILDING WITH KRONE CONNECTORS
772SUPPLY OF EXHAUST FAN OF AC 230/250 V, 50 Hz INCLUDING NUTS & BOLTS, MOUNTING FRAME AND OTHER ACCESSORIES.300 MM SWEEP
773SUPPLY OF ENERGY METER (3 PHASE) AND OTHER ACCESSORIES.
774SUPPLY OF WALL FANOF AC 230/250 V, 50 Hz INCLUDING NUTS & BOLTS, MOUNTING FRAME AND OTHER ACCESSORIES. 450 MM SWEEP
775SUPPLY OF EXHAUST FAN OF AC 230/250 V, 50 Hz INCLUDING NUTS & BOLTS, MOUNTING FRAME AND OTHER ACCESSORIES.450 MM SWEEP
776SUPPLY OF WEIRED DECORATIVE MIRROR LIGHT SUITABLE 9 WATT LED WITH LAMP COMPLETE
777SUPPLY OF FACTORY WEIRED INTEGRAL LED FLOOD LIGHT LUMINARIES WITH DIE CAST ALUMINIUM HOUSING BUILT WITH DRIVER SET SUITABLE FOR 40 TO 50 WATT CONFOMING TO IP 65/66 PROTECTION COMPLETE.
778SUPPLY OF SWICHES (MODULAR) 5 AMP
779SUPPLY OF SOCKETS (MODULAR) 5 AMP
780SUPPLY OF PVC CONDUIT PIPE 25 MM DIA
781SUPPLY OF ROUND SHEET
782SUPPLY OF CEILING ROSE
783SUPPLY OF HOLDER FOR BULBS
784FIXING OF MAIN LT PANEL
785FIXING OF MAIN EM PANEL
786FIXING OF SUB PANEL
787FIXING OF SUB EM PANEL
788FIXING OF CAPACITOR PANEL 150KVAR
789FIXING OF FEEDER PILLER
790FIXING OF STREET FEEDER PILLER
791Supply of Coarse sand
792Supply of Cement50 KG
793Supply of Brick M150
794Supply of Stone Grit 20 mm
795Supply of Stone Ballast 40 mm
796Supply of Tor Steel 8 mm dia
797Supply of Tor Steel 10 mm dia
798Supply of Tor Steel 12 mm dia
799Supply of Tor Steel 16 mm dia
800Supply of Tor Steel 20 mm dia
801Supply of Tor Steel 25 mm dia
802Supply of MS Fabrication For Door Window and Ventilator
803Supply of Water Proofing Chemical CICO TAPECRETE P151
804Supply of Y Shaped Angle Iron Post 40x40x6
805Supply of Kota Stone 22 mm thick
806Supply of Vitriried Floor Tile 8 to 10 mm thick in 600x600 mm size
807Supply of Wall Tile Glazed/ Ceramic floor tiles
808Supply of SS Railing 304 grade
809Supply of MS Collapsible Channel
810Supply of Rolling Shutter With Ball Bearing
811Supply of Granite
812Supply of Cinder
813Supply ofChequred Tile 300x300 mm size
814Supply of MS Gate made of MS Hollow sections
815Supply of INTERLOCKING PAVERS 80 MM M30 Mpa
Disclaimer :