| 1 | Construction of dwelling unit (Type E quarter) for General Manager at Chimiri Colony |
| 2 | Earth work in excavation in foundation and trenches in soils containing 50% or more of shingle or small size boulders upto 30 cm size, lift upto 1.50 m and stacking the excavatedsoil not more than 3 m clear from the edge of the excavation and returning the stacked soil in 15 cm layers when required, into plinth, sides of foundation etc consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated soil as directed within a lead of 50m. |
| 3 | Filling in plinth with sand under floors including watering, ramming, consolidating and dressingcomplete. |
| 4 | Dry rubble Flooring |
| 5 | Providing and laying in foundations and plinth cement concrete 1 : 4 : 8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) excluding the cost of centring and shuttering. |
| 6 | Centring and shuttering including strutting proping etc. and removal of form work for: a) For foundations and plinth |
| 7 | Reinforcement of RCC work including, Cutting, bending, binding and placing in position complete. B) For Tar/TMT Bars |
| 8 | Reinforced concrete work in foundations, footings, bases of columns etc. and mass concrete excluding cost of centring, shuttering and reinforcement in M-20 grade(1 cement :1.5 sand : 3 stone aggrigate 20mm normal size). |
| 9 | Random rubble masonry with hard stone in foundations and plinth in cement mortar 1 : 6 (1 cement : 6 fine sand) including levelling up with cement concrete 1 :6 : 12 (1 cement : 6 coarse sand : 12 stone aggregate 20 mm nominal size) at plinth level. |
| 10 | Providing and laying cement concrete 1 : 3 : 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) excluding the cost of centring an shuttering in:a) Foundations & plinth |
| 11 | Providing and fixing in position factory made EPS cement sandwich wall/roof/floor light weight solid core panels made of core material of EPS granule balls/beads (conforming to IS 4671:1984 and shall have density not less than 15kg per cum) adhesive, cement, sand, flyash and other bonding material in mortar state processed to form in a preset mould. The outer face on both sides of the panels will be non asbestos fiber cement board confirming to IS 14862:2000 or Calcium silicate board confirming to EN 14306:2009 of 5mm thick each. Panel shall be laid on 6mm thick cement mortar (1 cement: 2 fine sand) mixed with chemical adhesive of 0.5kg per 50kg of cement or shall be preferably fixed into \"C\" channel made of 1.2mm thick MS plate screwed/fastenened to the slab/column/beam etc. The panel shall fixed vertically with tongue and groove joint and horizontally locked with steel bar between each other and floors and filled with cement mortar and adhesive. Panels should be used as floor & roofing with additional structural support, steel or RCC depending upon the design. All the operation shall be completed in all respect as per drawings, Manufacturers specifications and under the overall direction of Engineer-in-Charge (Cost of all the material is included except \"C channel\" which will be paid seperately).Non load bearing panels 75mm thick of required size |
| 12 | Providing and applying plaster of paris putty of 2 mm thickness over plasteredsurface to prepare the surface even and smooth complete. |
| 13 | Applying one coat of cement primer of approved brand and manufacture on wall surface.(Internal walls) |
| 14 | Wall painting (two or coats) with plastic emulsion paint of approved brand andmanufacture on new work to give an even shade. |
| 15 | Applying one coat of cement primer of approved brand and manufacture on wallsurface.(External walls) |
| 16 | Finishing walls with water proofing cement paint of approved brand andmanufacture and required shade on new work (three or more coats) to give aneven shade. |
| 17 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by themanufacturer) with water absorption less than 0.08% and conforming to IS : 15622, ofapproved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1cement : 4 coarse sand), including grouting the joints with white cement and matchingpigments etc., complete b) Size of Tile 600x600 mm |
| 18 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 ( thickness to be specified by the manufacturer) of approved make, in all colours and shades except burgundy, bottle green, black of any size as approved by Enineer- in- incharge in skirting,risers of steps dados, over 12 mm thick bed of cement mortar 1:3 ( 1 Cement: 3 coarse sand)and jointing with gray cement slurry @ 3.3 kgs per sq.m, including pointing in white cement mixed with pigmment of matching shade complete. |
| 19 | Providing and fixing aluminium work for doors, windows, ventilators and partitions withextruded built up standard tubular sections appropriate Z sections and er sections ofapproved make conforming to IS: 733 and IS: 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gagps at junctions, at top, bottom and sides with required PVC/ neoprene felt etc. Aluminiumsections shall be smooth, rust free straight, mitred and jointed mechanically wheeverrequired including cleate angle Aluminium snap beading for glazing/ panelling, C.P.Brass/ stainless steel screws, all copmplete as per Architectural drawings and the directions of Engineer-in-incharge (glazing panelling to be paid seperately) . For fixed portion.Powder coated Aluminium ( Minimum thickness of powder coating 50 micron) |
| 20 | Providing and fixing of Aluminium shutters for doors, windows & ventilators includingproviding and fixing hinges/ pivots and making provision of fixing of fittings whereverrequired including the cost of PVC/neoprene gasket required ( Fittings shall be paid forseparately) Powder coated Aluminium ( Minimum thickness of powder coating 50 micron) |
| 21 | Providing and fixing glazing in Aluminium door, window, ventilator shutters and partitionsetc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and thedirections of Engineer-in-charge( cost of aluminium snap beeding shall be paid in basicitem ) With floatGlass panels of5.5mm Thickness (for windows). |
| 22 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windowsand clerestory windows using wire gauge with average width of aperture 1.4 mmin both directions with wire of dia. 0.50 mm all complete. A)With 12 mm mild steel Ubeading |
| 23 | Providing and fixing 12mm thick Pre-laminated particle board flat pressed three layer orgraded wood particle board conforming to IS: 12823 Grade 1 Type II, in panelling fixed inAluminium doors, windows shutters and partition frames with C.P brass / Stanless steelscrews etc. complete as per Architectural drawings and directions of Engineer - in - charge.Pre- Laminated particle board with decorative lamination on both sides |
| 24 | SANITARY ITEMS |
| 25 | Providing and fixing white vitreous china pedestal type water closet ( European typeW.C.pan)with seat & lid, 10 litre low level white P.V.C flushing cistern, including flush pipe, with maually controlled device ( handle lever) conforming to IS: 7231, with all fittings and fixures complete, including cutting and making the good the walls and floors wherever required .(a) W.C. pan with ISI marked white solid plastic seat and lid |
| 26 | Providing and fixing white vitreous china wash basin with RS or CI brackets painted white15mm. C.P.Brass piller tap and C.P.brass chain with rubber plug 32mm C.P brass waste of standard pattern,32mm dia C.P.brass trap and MI unions complete, including cutting and making good the walls where required. a) Flat back wash basin size 550x400 mm with a pair of 15 mm CP brass pillar taps of heavy quality. |
| 27 | Providing and fixing 600x450 mm bevelled edge mirror or superior glass (of approvedquality) complete with 6mm. Thck asbestos sheeet ground fixed to woooden cleat withC.P.brass screws and washers |
| 28 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.d) 32 mm nominal outer dia. Pipes |
| 29 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(a) external works (vi)50mm nominal outer dia. Pipes |
| 30 | Providing and fixing GI pipes complete with GI fittings including trenching andrefilling etc (external work). (e) 40mm nominal bore |
| 31 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality and make asapproved Engineer -in -charge. a ) 15mm nominal dia. |
| 32 | Providing and fixing CP brass shower rose with 15 mm or 20 mm dia inlet.a) 100 mm dia |
| 33 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long withS.S.triangular plate to Europian type W.C of quality and make as approved by Engineer -incharge |
| 34 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:113983 withC.I.brackets and stainless steel plug 40mm, including painting of fittings & brackets,cutting making the good walls wherever required. a) kitchen sink with drain board.i) 510x1040 mm bowl depth 250 mm |
| 35 | Providing and fixing toilet paper holder. a) CP Brass |
| 36 | Providing and fixing sand cast iron/ cast iron (spun) soil, waste and vent pipes.a) 100 mm dia |
| 37 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to ISstandards and weighing not less than 690 gms a) 15mm nominal bore |
| 38 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approvedquality conforming to IS 8931. a) 15mm nominal bore |
| 39 | Providing and fixing PTMT grating of approved quality and colour. Circular type 100mm nominal dia. |
| 40 | Providing and fixing PTMT soap Dish Holder having length of 138mm,breadth 102mm,height of 75mm with concealed fitting arrangements weighing not less than 106 gms. Soap dish holder |
| 41 | Providing and fixing P.V.C. connection pipe brass union (B) 45 cm length (a)15mm nomonal bore |
| 42 | Providing and placing on terrace ( at all floor levels) polyethylene water storage tank, IS :12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow ppipes but without fittings and the base support for tank |
| 43 | Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC waste fittingscomplete (a) Semi rigidpipe (i) 32 mm dia. |
| 44 | Providing and fixing P.V.C. waste pipe for sink or wash basin including PVC waste fittingscomplete(a) Semi rigidpipe (i) 40 mm dia. |
| 45 | Providing and fixing plain bend of required degree.100 mm dia Sand cast iron S&S as per IS - 1729 |
| 46 | Providing and fixing bend of required degree with access door, insertion rubberwasher 3 mm thick, bolts and nuts complete.100 mm dia Sand cast iron S&S as per IS - 1729 |
| 47 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P type/With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 48 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 49 | Providing and fixing sand cast iron trap of self cleaning design with sand cast ironscrewed down or hinged grating with or without vent arm complete including cost ofcutting and making good the walls and floors.a) 100 mm inlet and 100 mm outlet |
| 50 | Making soak pit 2.50 m dia 3 m deep with 45 x 45 cm dry brick honeycomb shaft and SWdrain pipe 100 mm dia 1.80 m long complete as per standard design. |
| 51 | Providing and fixing CP brass towel rail complete with CP brass brackets fixed to woodencleats with CP brass screws (heavy quality). a) 750 x 20 mm size |
| 52 | Providing and fixing 600 x 120 mm glass shelf with CP brass brackets and guard railcomplete, fixed to wooden cleats with CP brass screws. |
| 53 | Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1cement : 2 fine sand) in S.C.I./ C.I. Pipes : 100 mm dia pipe |
| 54 | Structural steel work riveted, bolted or welded in built up sections,trusses and framed work,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 55 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed withpolymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpetwashers or with G.I. limpet washers filled with white lead, including a coat of approvedsteel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces),excluding the cost of purlins,rafters and trusses and including cutting to size and shape wherever required. 0.80 mm thick with zinc coating not less than 275 gm/m² |
| 56 | Providing and fixing false ceiling at all height including providing and fixing of frame work, made of special sectoin, power pressed fromM.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre,shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : (a)12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks) |
| 57 | Construction of cement concrete drain 15 cm wide and 15 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips or shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering and all exposed surfaces with 12 mm thick cement mortar 1 : 3 (1 cement : 3 coarse sand) including shuttering complete. |
| 58 | Making plinth protection 50 mm thick of cement concrete 1 : 3 : 6 (1 cement : 3 coarsesand : 6 stone aggregate using 20 mm nominal size) over 75 mm bed of stone ballast 40mm nominal size well rammed and consolidated and grouted with fine sand includingfinsihing the top smooth. |
| 59 | Providing and fixing MS sliding door bolts, bright finished or and black enamelled with nutsand screws etc complete b)250x16mm |
| 60 | Providing and fixing MS tower bolts (barrel type) with necessary screws etc complete.(c) 150x10mm |
| 61 | Providing and fixing MS handles with necessary screws etc complete. a) 125mm |
| 62 | Providing and fixing MS handles with necessary screws etc complete. b) 100 mm |
| 63 | Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flat, square or round bars with round headed bolts and nuts or by screws.a) Plain grill. |
| 64 | Painting two or more coats (excluding priming coat) with superior ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give an even shade. |
| 65 | Loading and Unloading of Stone Boulder / Stone aggregates / Sand /Kanker/Moorum / Lime/ Shingle /Surki/ Earth / Excavated Rock and Kerb Stones by Manual Means for hill roads. |
| 66 | Loading and Unloading of Cement / Steel / Structural Steel / RC Pipe /Wooden Logs / Bricks/ Bitumen and Timber etc, by Manual Means and Stacking for hill roads. |
| 67 | Cost of Haulage Excluding Loading and Unloading on hill roads . Haulage of materials bytipper excluding cost of loading, unloading and stacking. Surfaced Road |
| 68 | Providing and laying cement concrete 1 : 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) excluding the cost of centring and shuttering in : a) Foundations and plinth |
| 69 | Brick work with best available local bricks in foundations and plinth in cementmortar 1:4 (1 cement : 4 fine sand) |
| 70 | 20 mm cement plaster 1 : 4 (1 cement : 4 fine sand) |
| 71 | Neat cement punning |
| 72 | Providing and fixing on wall face asbestos cement soil, waste and vent pipes includingjointing with spun yurn soaked in bitumen and cement mortar 1 : 2 (1 cement : 2 coarsesand) complete b) 80 mm dia |