| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-04-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 13-04-2023 |
| 2 | 03-04-2023 | FINANCIAL BID CORRIGENDUM 2 | Financial Bid | 06-04-2023 |
| 3 | 28-03-2023 | FINANCIAL BID CORRIGENDUM | Financial Bid | 06-04-2023 |
| 4 | 28-03-2023 | BOQ CORRIGENDUM | BOQ | 06-04-2023 |
| Sl. No. | Item Description |
| 1 | Surface dressing n.exc 15 cm deep as in hard/dense soil complete all as specified and directed. |
| 2 | Removing excavated materials exc 1.5 Km but n. exc 5 Km and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed. |
| 3 | Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depthfor foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/disintegrated rock complete all as specified and as directed. |
| 4 | Excavating in trenches not exc. 1.5 metre wide and exc. 1.5 metre & not exc. 3 metre depth (beyond the first 1.5 metre) for foundation of poles etc and getting out in soft/disintegrated rock complete all as specified and directed. |
| 5 | Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out in soft/disintegrated rock complete all as specified and directed. |
| 6 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/disintegrated rock complete all as specified and directed. |
| 7 | Removing excavated materials exc 500 m but n. exc 1.5 Km and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed. |
| 8 | M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed. |
| 9 | M & L for use & waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter complete all asspecified and directed. |
| 10 | M & L for use & waste Formwork to sides of pillars, posts, struts, piers, columns and stanchionsfor flat rough finished surfaces of concrete complete all as specified anddirected. |
| 11 | M & L for use & waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etcetc complete all as specified anddirected. |
| 12 | M & L for use & waste Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizonal or sloping) for flat rough finished surfaces of concrete complete all as specified and directed. |
| 13 | M & L for use & waste Form work to chajjas, troughs and similar items including edges flat for rough finished surfaces of concretecomplete all as specified and directed. |
| 14 | M & Lfor Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in foundations including rafts, footings, beams and mass concrete, etc complete all as specified and directed. (Note\" Reinforcement will be measured and paid seperately) |
| 15 | M & L for Reinforced Cement ConcreteM-30 (Design Mix) (using 20 mm graded stone aggregate) as in columns, pillars, posts and struts complete all as specified and directed. (Note :Reinforcement will be measured & paid seperately) |
| 16 | M & L Reinforced Cement ConcreteM-30 (Design Mix) (using 20 mm graded stone aggregate) as in beams, cantilevers, lintels over 1.5m span complete all as specified and directed.(Note :Reinforcement will be measured & paid seperately) |
| 17 | M & L for Reinforced Cement Concrete M-30 Design Mix (Using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, and in shelves and the like etc complete all as specified anddirected. (Note: Reinforcement will be measured and paid seperately) |
| 18 | M & L Reinforced Cement ConcreteM-30 (Design Mix) (using 20 mm graded stone aggregate) as in chajjas etc complete all as specified and directed.(Note :Reinforcement will be measured & paid seperately) |
| 19 | S & F high strength corrosion resistant TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed. |
| 20 | S & F high strength corrosion resistantMild steel TMT bars 5mm dia and over upto and including 10mm dia in strirrups, spacers and binders spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed. |
| 21 | M & L for Brick work with fly ash brick, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 using old size brick complete all as specified and directed. |
| 22 | M & L for Antitermite treatment by treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. |
| 23 | M & L for Antitermite treatment by treatingthe backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed. |
| 24 | M & L for Antitermite treatment by treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed. |
| 25 | M & L for Antitermite treatment by treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. |
| 26 | M & L for Antitermite treatment by treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed. |
| 27 | M & L for rendering 5 mm thick in cement mortor 1:3 on concrete surfaces as in ceilings and finishing surfaces even and smooth without using extra cement complete all as specified and directed. |
| 28 | M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and fair without using extra cement complete all as specified and directed. |
| 29 | M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4,mixed with integral water proofing compoundwith weight of cement in top layer as per manufacturer\"s instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item). |
| 30 | Supply only integral water proofing compound (ISI marked) complete all as specified and directed. |
| 31 | M & L for 10 mm thick screed bed in CM 1:4 mixed with WPC as per manufacturer\"s instructions over 25 mm thick PCC 1:2:4 type B-0 (12.5mm graded aggregate), as in levellig course, Supply and lay polymeric water proofing membrane of weight 3kg/sq.m incorporating a centre core of 90 micron thick HMHDPE film including coating the surface with a coat of water based bituminous primer @ 100gms/sq.m., followed by a coat of blown bitumen of grade 85/25 or 90/15 @ 1.2kg/sq.m. each at top and bottom of the membrane including sealing all joints by thermo fusion with minium 10cm overlap inclgrooving & inserting in parapt wall all as per manufacturers instructions complete all as specified and as directed. (Note: WPC shall be measured and paid seperately) |
| 32 | S & F Well seasoned 2nd class hard wood plain, solid, straight chowkat and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed. |
| 33 | M & L for Plain cement concrete 1:3:6, type C-1, (using 20 mm graded stone aggregate) as in lintel upto 1.5m span, cills and other similar band, plinth course, parapet, railing upto 60cm height, coping, kneelers, bed plates, hold fast block etc including weathering slightly rounded or chamfered angles including necessary form work complete all as specified and directed. |
| 34 | M & L for Mild steel Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 35 | S & F 35 mm thick, factory made Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 36 | S & F 35 mm thick, factory made, glazed/skeleton shutters with second class hard wood,open rebated and prepared to receive glass, gauze, etc (without sash bars)edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass, etc complete as specified and directed . Sizes of members of shutters as specified in SSR Part I complete all as specified and directed |
| 37 | S & F solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed. |
| 38 | S & FFactory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, complete as per specification and drawing and as directed. |
| 39 | Providing and fixing factory made uPVC white colour Sliding window Three track Area not exceeding 2.00 sqm each made of extruded profiles with wall thickness of 2.3mm (+/-0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead(24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2 (+/-0.2)mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories complete all as specified and directed. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose.) |
| 40 | S & F 100 mm size, butt hinges, medium weight, cold rolled mild steel complete all as specified and directed. |
| 41 | S & F 200 mm long, Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 42 | S & F 150 mm size, extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 43 | S & F Aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sectionsor cast aluminium alloy, length of bolt of 300 mm complete all as specified and directed. |
| 44 | S & F Floor door stopper of aluminium alloy body and tongue, anodised, 150 mm overall length of cover plate with hard drawn steel spring, fixed in floorcomplete all as specified and directed. |
| 45 | S & F 4 mm thick, sheet glass, ordinary quality and glazing to aluminium window exceeding 0.5 Sqm in each pane complete all as specified and as directed. (Note: The cost of glazing beads included with the respective items of shutter) |
| 46 | S & FStainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified and directed. |
| 47 | M & L for Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed. |
| 48 | M & L for preparing newly plastered surfaces of internal walls, etc by \"Vacuum based sandng machine\" and applying two coats of distemper oil emulsion over a coat of alkali resistant primer by \"Auto Roller\" and over one or more coats of wall care putty to a smooth surface complete all as specified and directed.(Note: Multipurpose mixer shall be used for uniform and proper mixing of putty) |
| 49 | M & L for preparation new external surfaces of wall, chajja, facia etc by \"Vaccum based sanding machine\" and applying two coats of water based acrylic weather proof exterior emulsion (exterior wall finish) paint over a coat of primer by \"Auto Roller\" machine as per manufacturer\"s instruction complete all as specified and directed. |
| 50 | M & L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 51 | M & L for Sand filling under floors or in foundations including spreading, levelling, watering and consolidation complete all as specified and directed. |
| 52 | M & L for hardcore of gauge n.exc 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 53 | M & L for moorum/red bajri filling under floors or in foundations including spreading, levelling, watering and consolidation complete all as specified and directed. |
| 54 | M & L for 75 mm thick,plain cement concrete1:3:6, type C-1 (using 20mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed. |
| 55 | M & L for 100 mm thick, Cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in base of flooring/hard standing, etc, complete all as specified and directed. |
| 56 | M & L for Chequered cement concrete tiles of size 20cm x 20cm x 25mm thick, as in floors etc,including 15 mm thick screed bed in cement mortar 1:6 and set & jointedin neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and directed. |
| 57 | M & L for cement concrete tiles of size 25cm x 25cm x 22mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished,including 15 mm thick screed bed in cement mortar 1:6 and set & jointedin neat cement slurry and pointed in with mixture of white and grey cement equal proportion and no pigment complete all as specified and directed. |
| 58 | M & L for 75 mm thick, plain cement concrete 1:4:8,type D-2 (using 40 mm graded stone aggregate)as in sub-base of flooring, etccomplete all as specified and directed. |
| 59 | M & L for 25 mm thick, plain cement concrete 1:2:4,type B-0 (using 12.5 mm graded stone aggregate)as in sub-base of flooring, etc and finished the surface even and rough complete all as specified and directed. |
| 60 | M & L for Vitrified, designed, dark shade/double charged/ ultracharged coloured, tiles, 7 to 8 mm thick, (square/rectangular) polished, area of each tiles not exc 0.36 sqm, in floors, etc including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 61 | M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 62 | M & L for Glazed, ceramic, colouredtiles of size 300mm x 200mm x 6-7mm thick, on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortor 1:4 and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed. |
| 63 | S & F 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed. |
| 64 | S & F 75 mm bore, PVC (SWR),Soil, waste and vent pipes, single socketed in any length with rubber ring joints fixed to walls, etc completeall as specified and directed. |
| 65 | S & F 110 mm bore, PVC (SWR) bends of any radius complete all as specified and directed. |
| 66 | S & F75 mm bore, PVC (SWR) bends of any radius complete all as specified and directed. |
| 67 | S & F vitreous China wash basin, size 550 x 400mm, white, flat back including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and directed. |
| 68 | S & F 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered \"Hot or Cold\" with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed. |
| 69 | S & F 32 mm diaWaste fittings, brass, chromium plated for glazed ware sinks, basins,etc. with long screwed shanks and fly-nuts, flange end beddedinred leadcement and other end fixedcomplete all as specified and directed. |
| 70 | S & F 32mm dia flexible PVC waste pipe for wash basin complete all as specified and directed |
| 71 | S & F 15mm bore, PVC connection pipe 600mm long with PTMT nuts at both ends complete all as specified and directed. |
| 72 | S & F Vitreous China wash down water closet pan (pedestal pattern), white, including connection to outgoing drain andflushing pipe, anti syphonic pipe with seat and cover complete but excluding flushing cistern & flush pipe including making good damaged/disturbed surfaces complete all as specified and directed. |
| 73 | S & F 10 litre capacity, PVC valve less syphonic action type, flushing cistern, low level, white,with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and directed. |
| 74 | S & F Vitreous China bowl urinal flat back, of size 465x355x265mm, white (minimum) with grating and union for discharge pipe (excluding flushing cistern, flush pipe & waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement complete complete as specified and directed. |
| 75 | S & F 15 mm bore, angular stop cock, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 76 | S & F Hand Shower (Health Faucet) with 1 Meter Long Easy Flex Tube in Chrome Finish & Wall Hook, 15mm bore complete all as specified and directed. (Make: Jaquar Cat No. ALD-565 or equivelant of make as per List of manufacturer\"s) |
| 77 | S & F 15mm bore, bib taps, fancy type, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 78 | S & F 600mmX450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plug with chromiun plated brass screws and cup washers complete all as specified and directed. |
| 79 | Supply, laying, connection and testing, 16mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed |
| 80 | Supply, laying, connection and testing, 20mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed |
| 81 | Supply, laying, connection and testing, 25mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed |
| 82 | Supply, laying, connection and testing, 32mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed |
| 83 | S & F 75 mm bore, PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed. |
| 84 | S & F 1000 litres capacityrotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top), hoisted and fixed in position as specified in SSR Part I and directed. |
| 85 | S & F 20 mm bore,ball brass valves, high pressure, with polythene float and fly nuts, screwed for iron pipe or brass ferrule complete all as specified and directed. |
| 86 | S & F 20 mm bore, gun metal Gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and directed. |
| 87 | Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal ofdebris and rubbish to a distance n.exc 100m as directed by the Engr-in-Charge. |
| 88 | S & F 30mm thick Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive trength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body hreaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges with S S screws shall be paid separately) complete all as specified and directed. |
| 89 | S & F 125 mm long, stainless steel butt hinges fixed with stainless steel hinge pin etc complete all as specified and directed. |
| 90 | S & F 150 mm long, Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. |
| 91 | S & F GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to cerntre / intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete including Hangers 6 mm dia GI (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia, 40 mm long including 12mm thick, Gypsum Board as in ceiling fixed with screws as per manufacturers instructions complete all as specified and directed by the Engr-in-Charge. |
| 92 | M & L for 18 to 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 15 mm thick screed bed in cement mortor 1:6 & cutting, polishing complete all as specified and directed. |
| 93 | M & L for plain cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork complete all as specified and as directed. |
| 94 | M & L for Precast Reinforced Cement Concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in cover slab (For manhole etc), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain facesand set in cement mortar 1:4 including necessary form, moulds, etc complete all as specified and directed by the Engr-in-Charge. (Note : Reinforcement shall be measuredand paid separately) |
| 95 | M & L for Salt glazed stone ware drain pipes 150 mm bore, grade \"A\" laid in trenches, jointed and tested complete all as specified and directed. |
| 96 | M & L for Plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggragate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore SGSW/RCC drain pipes complete all as specified and directed . |
| 97 | M & L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required for 150 mm bore of pipe complete all as specifieed and directed. |
| 98 | M & L for preparation of old decorated surfaces of walls after complete removal of existing treatment and applying three coats of white wash complete all as specified and directed. |
| 99 | Taking down carefully unserviceable aluminium/copperpoint wiring (light, fan, socket or power) complete, (fitting such as switches, ceiling roses, pendants, regulators, sockets, etc to be measured separately if found serviceable), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed. |
| 100 | Taking down unserviceable main switches, DBs, bus bars chambers any capacityincluding all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified anddirected. |
| 101 | Taking down unserviceable sub-main wiring (any numbers of cable) withrigid PVC/steelconduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed. |
| 102 | M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) concealed type including sunken type metal GI boxes fo suitable size including Modular white coper plate for fixing modular type type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductorcable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed,for one light/exhaust fan/fan point/call bellcontrolled by one way switch.(Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface. (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one) |
| 103 | All as per item No. 102 above but for One light point controlled by two Nos two way switch complete ditto |
| 104 | All as per item No. 102 above but forOne 3/5 pin socket outlet 6 amps on independent board complete ditto |
| 105 | All as per item No. 102 above but for One 3/5 pin socket outlet 6 amps pointon same boardcomplete ditto |
| 106 | All as per item No. 102 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistrandedFRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cableFRLS (ISI marked) as earth lead complete ditto |
| 107 | All as per item No. 102 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 4 sqmm multistrandedFRLS (ISI marked) and 4 sqmm PVC insulated unsheathed solid copper conductor cableFRLS (ISI marked) as earth lead complete ditto |
| 108 | S & F switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed. |
| 109 | S & F Modular socket outlet6A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed. |
| 110 | S & F switch modular single pole Two way 6 amp 240 volts,1 module complete all as specified and as directed. |
| 111 | S & F switch modular single pole one way 16 amp 240 volts,1 Module complete all as specified and as directed. |
| 112 | S & F Modular socket outlet6A/16A, 2/3 pin combined, 2 module, AC 230V, 50HZ complete all as specified and as directed. |
| 113 | S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed. |
| 114 | S & F modular bell push 6 amp 240 volts1 module,complete all as specified and as directed. |
| 115 | S & F Bell electric, Ding Dong AC 230 Volts, single pole complete all as specified and as directed. |
| 116 | S & F steped type modular fan regulator ,100/120 W 1/ 2 module complete all as specified and as directed. |
| 117 | S & F Concealed sheet metal enclosurewith socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20Amp 240V, B-curve complete all as specified and as directed. |
| 118 | S & F TV Socket modular 1 module with metal box minicomplete all as specified and as directed. |
| 119 | S & F LED tube light fittings, retro bar professional WH 5700K to 6000K, 20 Watt and 2000 Lumens of cool white with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specifiedand directed. (Make: Havell\"s Cat No. LUMILINEPLUSBS20WLED865SPCSS or equivelant of make as per list of manufacturer) |
| 120 | S & F Surface and wall mounted LED batten, 10W, 220V, AC, 2 feet, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver with industrial grade heavy duty driver having THD<10%including lamp, fixing accessories and connecting up complete all as specifiedand directed. (Make : Havell\"s Cat No. ENDURALINEARNEOBS10WLED865SPCWH and equivelant model of make as specified in list of manufacturer). |
| 121 | S & F LED 30 Watt, 3300 Lumen street light luminaire, made up of pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP65 protection with lamp and all accessories including mounting clamps, bolts, nuts and washers, 1.5 Sqmm weather proof 3 core FRLS grade copper conductor cable to fittings of suitable length complete all as specified and as directed. (Make: CG Cat No. LSTS-30-CDL-M or equivelant of make as per list of manufacturer) |
| 122 | Taking down carefully by unscrewing from boards/outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse) complete all as directed. |
| 123 | Fixing only serviceable light fittings any type including connecting up complete all as specified and directed (Note: Old serviceable light fittings as obtained from serial Item No 122 here -in-before shall be re-used). |
| 124 | S & F 2x2 recessed mounting, LED panel light fittings, 36 Watt with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specifiedand directed. (Make: Havell\"s Cat No. VENUSNEOHE2X2R36WLED840PIRSENSOR or equivelant of make as per list of manufacturer) |
| 125 | S & F LED 45 Watt street light luminaire, street light made up of pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP65 protection of Efficacy : 110LM/W including lamp and all accessories including mounting clamps, bolts, nuts and washers, 1.5 Sqmm weather proof 3 core FRLS grade copper conductor cable to fittings of suitable length complete all as specified and as directed. (Make: CG Cat No. LSTS-45-CDL-M or equivelant of make as per list of manufacturer) |
| 126 | Supply, fix, installation and commissioning BLDC ceiling fan of less noise, silent operation, speed controlable by regulator, light colour, conforming to IS-374-2019, 1200 mm sweep, 230 Volts, BEE 5 Star rating, any Govt recognised Lab tested, power factor >0.94 Wattage and not more than 35 Watt, air delivery not less than 215cmm alongwith electronic type regulator and all accessories such as down rod etc and connecting up with 1.5 Sqmm, PVC insulated, multistranded copper conductor cables from ceiling rose to fan complete all as specified and directed. (Note: Ceiling fan should have minimum 3 years manufacturer\"s warranty)(Make : USHA/Havell\"s/Bajaj/CG) |
| 127 | S & F Distribution Board,TPN, 6 Way, 415V, Doubledoorwith IP 43 protection, IK 09 complete all as specified and as diretcedcomplete all as specified and directed.(Make: Legrand cat part No. 5076 71 or equivalent make as per List of Manufacturer\"s) |
| 128 | S & F Distribution Board, SPN 12 Way, 240V, Double door with IP 43 protection, IK 09complete all as specified and as directed. (Make: Legrand cat part No. 5076 12 or equivalent make as per List of Manufacturer\"s) |
| 129 | S & F Distribution Board,TPN, 8 way, 415V, Doubledoor with IP 43 protection complete all as specified and as diretcedcomplete all as specified and directed.(Make : Legrand Cat Part No. 5076 11 or equivelant of make as per List of manufacturer\"s) |
| 130 | S & F Distribution Board, SPN 8 Way, 240V, Double door with IP 43 protection IK 09 complete all as specified and as directed. (Make: Legrand cat part No. 5076 11 or equivalent make as per List of Manufacturer\"s) |
| 131 | S & F Vertical TPN DB double door for provision for four pole MCCBupto 160 A incommer 8 way 12 outgoing with IP 43 protectioncomplete all as specified and as directed. (Make : Legrand cat part No. 5077 47 or equivelant of make as per List of manufacturer\"s) |
| 132 | Supply, fixing, commissioning and testing MCB SPN 6-32A Amps, 240 Volts,10KA, C Curve complete all as specified and as directed (Make: Legrand cat part No. 4086 14 to 17 or equivalent make as per List of Manufacturer\"s) |
| 133 | Supply, fixing, commissioning and testing MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve,complete all as specified and as directed (Make: Havell\"s cat part No. DHMGCSPF006-032 or equivalent make as per List of Manufacturer\"s) |
| 134 | Supply, fixing, commissioning and testing MCB, TPN 40-63 Amps, 415 Volts, 10KA,C Curve complete all as specified and as directed(Make : Legrand Cat part No. 4086 81 to 83or equivelant of make as perList of manufacturer\"s) |
| 135 | S & F MCCB 415 Volt, 25 KA, 4 Pole, 200 Amps Capacity complete all as specified and as directed. (Make: Legrand Cat Part No. 4202 18or equivelant of make as per List of Manufacturer\"s) |
| 136 | M & L for Sub main wiring with 4 runs of Single core 10 sqmm [ for Phase & Neutral ]PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size with all conduit accesories and fittings along with one run of single core 10 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cableas earth continuity conductorcomplete all as specified and as directed.(Note :- (ii) Four runs of 10 sqmm and two runs of 10 sqmm cable as earth wire and one run of conduitshall be measured as one length (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one) |
| 137 | M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ]PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cableas earth continuity conductorcomplete all as specified and as directed.(Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduitshall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one) |
| 138 | M & L for Sub main wiring with 2 runs of Single core 4 sqmm [ for Phase & Neutral ]PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 4 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cableas earth continuity conductorcomplete all as specified and as directed.(Note :- (i)Two runs of 4 sqmm and one runs of 4 sqmm cable as earth wire and one run of conduitshall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one ) |
| 139 | M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ]PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (Medium grade) with all conduit accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cableas earth continuity conductorcomplete all as specified and as directed.(Note :- (i) Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduitshall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one ) |
| 140 | M & L for Sub main wiring with 2 runs of Single core 1.5 sqmm [ for Phase & Neutral ]PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size (medium grade) with all conduit accesories and fittings along with 1 run of single core 1.5 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cableas earth continuity conductorcomplete all as specified and as directed.(Note :- (i) Two runs of 1.5 sqmm and one runs of 1.5 sqmm cable as earth wire and one run of conduitshall be measured as one length, (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one) |
| 141 | M & L for Sub main wiring with 4 runs of Single core 6 sqmm [ for Phase & Neutral ]PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including concealed PVC conduit of suitable size with all conduit accesories and fittings along with one run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cableas earth continuity conductorcomplete all as specified and as directed.(Note :- Four runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduitshall be measured as one length (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one) |
| 142 | M & L for Taking down ceiling fan any sweep from the existing poistion and replacing the defective parts such as shakle & clamps including, rubber bush, bolts, nuts & split pin (Chera Pin), washer etc. for ceiling fanand ensure proper inserting the quarter/ Split pin to hold the nut and bolt on fan downrod at fix position including servicing, oiling and greasing and spray painting with one coat of synthetic enamelled paint complete and re-fixing the ceiling fan of any sweep again at existing position complete all as specified and directed. |
| 143 | Taking down carefully existingexhaust fan of any size/sweep/make from it\"s existingposition, sealing cable end, dismantling blades, cleaning all dust etc including servicing, oiling and greasing and replacing minor defective parts etc and painting with one coat of synthetic enamel (1st grade quality white) paint by spraying including filling cavities with filler and marking same MES No. with parmanent marker etc and re-fixing the exhaust fan and connecting up complete all as directed. |
| 144 | M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar),including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed,including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge. |
| 145 | S & F in repairs 4mm dia galvanised iron or steel wire Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required complete all specified and directed. |
| 146 | S & F Telephone jack delux with shutter, 2 line with metal boxcomplete all as specified and as directed. |
| 147 | S & F Computer jack cat 6 with shutter with metal mini box complete all as specified and as directed. |
| 148 | S & F PVC insulated, 4 core, 4 pair telephone cable confirming to TEC specificationscomplete all as specified and as directed. |
| 149 | S & F electrolytic grade solid annealed bare copper conductor JF aluminium foiled and aluminium wire bare cable for TV connection complete all as specified and as directed. (Make: Havell\"s Code No. WHOJTTKARG59 or equivalent of make as per List of manufacturer\"s) |
| 150 | S & F electrolytic grade solid annealed bare copper conductor 4 pair unshield twisted pair for computer LAN cable with star seperatorcomplete all as specified and as directed. (Make: Havell\"s Code No. WHLJTTERCAT6 or equivalent of make as per List of manufacturer\"s) |
| 151 | S & F Rigid non-metalic PVC conduit (20mmdia) exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified and directed. |
| 152 | S & F 50 mm bore, Unplasticized PVC pipes of pressure rating 10 kgf/sq. cm fixed to walls, laid in floor etc completeall as specified and directed. |
| 153 | Supply, install, testing & Commissioning Dehumidifier, 15 litre per day capacity with min 2.3 Litre capapcity tank, 145 Watts with electric control, upto 24 Hours timer, rotary compressor, with auto restart function, with environment friendly refrigerant R134a, washable air filter, low noise and with water full alarm and automatic shut-off function including all connecting accessories complete all as specified and directed. (Make: Phillips/Sharp/Power Pye Electronic/LG/Origin) |
| 154 | S & F in repair lightening arrester +5 mtrs mounting mast with base plate, guy wire with flash counter with 5 mtr GI mast including PCC foundation of suitable size as per manufacturer\"s instructions as per the site requirement including necessary escavation and earth work complete all as specified and directed. (Make: ABB, Model OPR-60 ESE Type LPSr or equivelant of make as per List manufacturer) |
| 155 | Supply & Installation of advance conductive compound based chemical compound technology with upgraded high tensile low carbon steel rod as per UL 467 and as per BS 7430 with copper coating 250 microns. Earthing system confirming to IS:3034. The ROD should 17.2 mm & 3 meter length with rod to tape clamp, CR 125 (type A) additional protection of the terminal. Chemical compound should be the highly Conductive Compound as per BSEN 50164-7 with 25 kg each bag & resistivity should be 0.05 ohm. The job includes digging the pit and refilling the same by furse CEM back Fill Compound (Ground Enhancer), the BFC should be mixed with cement in 3:1 for forming conductive concrete and it should be eco friendly, not contain environmentally hazardous material/metal. The earth pit should be provided with a light weight inspection pit cover PT-205 for protection and safe guard of terminals. In areas where soil condition is bad Good earth is to be arranged to fill the excavated pits by mixing furse CEM- a convenient and permanent solution by adding with 3:1 ratio chemical compound with the earth electrode in the main component of the earthing system which is in direct contact with the ground and thus provides a mean of releasing or collecting earth leakage currents. The material should have good electrical conductivity and anti corrosion property in wide range of soil conditions including taking down existing earthing system and removing materials from site of workcomplete all as specified & directed . (Make : ABB Furse CEM as per RB 336 or equivalent).(NOTE :-Each earth pit should contain:-a) 1 No. copper bonded high tensile low carbon steel,17.2 mm dia, 3 meter length. b) Rod to tape clamp (type A).c) 25 kg chemical compound as per BSEN 50164-7. d) Light weight inspection pit cover with 5000 kg weight load capacity. e) Supply and installation shall be done by the authorised technician of the manufacturer) |
| 156 | S & F in repairs Test terminal box of size 175x150x100mm made out of 2mm thick hot dip galvanised sheet drilled and screwed including 4 nos 125mm long hexogonal head screwed with test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and as directed. |
| 157 | S & F in repairs earth continuity conductor or main earthing lead with copper strip of size 32 x 6 mm with saddles, porcelain insulators, nuts, bolts, screws, PVC plugs etc and fixing screws etc. for roof onductors and down conductors above ground complete all specification and directed. |
| 158 | S & F in repairs earth continuity conductor or main earthing lead with copper strip of size 20x3mm mm, fixed to wall on batten or recesses or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required complete all specification and directed. |
| 159 | S & F Dry chemical powder ABC type Fire Exitinguiser, 6 Kg capacity complete with intial charging, gun metal cap, discharge hose with nozzle, wall fixing brackets etc complete all specification and directed. |
| 160 | M & L for fabrication and construction of fire stand made of mild steel angle 50x50x6mm of overall size 1800x1500x900mm with bucket hanging arrangement including MS bucket 03 Nos of 450mm dia and fabrication of canopy with MS sheet of 18 SWG for protection from rain including necessary PCC foundation and necessary excavation and earth work complete and painting the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide zinch chrome primer after preparation of surfaces complete all as per the direction of Engr-in-Charge. |
| 161 | Supply, install, testing & Commissioning, 5 STAR rated Hi wall split type air conditioner with indoor and outdoor units complete with cordless remote control unit and with in-built advanced air filters for better indoor air quality with latest inverter technology, having eco friendly refrigerant gas, copper condenser coil, EER 4.5 or above of capacity 1.5 TR, summer cool, Inverter compressor, automatic 2D swing copper condenser, BLDC motor, necessary copper pipe connections including cutting, bending, brazing, insulation on pipes etc, PVC drain pipe, electric connection in between indoor and outdoor unit with suitable size of PVC insulated, multi-stranded copper cable complete with allfixing accessories such as bracket etc complete all as specified and directed. (Note: The unit rate quoted above shall deem to be inclusive of powder coated MS fixing brackets of suitable size for outdoor and indoor units at any height and copper tube of suitable size, drain pipe made of High Density Polyethylene pipes [HDPE] of pressure rating 6Kg/Sqcm of 20mm dia as required and 3 core, 4 Sqmm PVC insulated and PVC sheathed, heavy duty multi-stranded copper conductor cable, 1100 Volts, FRLS grade as required for connecting indoor and outdoor unit) |
| 162 | S & F voltage stabilizer for automatic operation,, single phase naturally air cooled indoor type and designed for inputvariationbetween 170 V to 250 V with output of 230V with accuracy of +/- 2.5% variation of capacity 5.0 KVA complete all as specified and directed. |
| 163 | S & F Electronic digital 2 AC timer for 02 Nos AC for server room pf programme for 1 Hr to 12 Hr as per matching existing AC and LCD display complete all as specified and directed. (Make Havell\"s/Dynamic/Everest) |