| Sl. No. | Item Description |
| 1 | CIVIL WORKS |
| 2 | EARTH WORKS |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. |
| 4 | All kinds of soil. |
| 5 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : |
| 6 | All kinds of soil. |
| 7 | Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia |
| 8 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 9 | Carriage of Earth by mechanical transport including loading, unloading and Stacking including royalty & carriage up to 5 KMcomplete. |
| 10 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. |
| 11 | All kinds of soil |
| 12 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 13 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 14 | Supplying chemical emulsion in sealed containers including delivery as specified |
| 15 | Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 16 | Anti termite treatment |
| 17 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : |
| 18 | Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: |
| 19 | With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
| 20 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : |
| 21 | With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. |
| 22 | CONCRETEWORKS |
| 23 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 24 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 25 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: |
| 26 | 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 27 | Centering and shuttering including strutting, propping etc. and removal of form work for : |
| 28 | Foundations, footings, bases for columns |
| 29 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size). |
| 30 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer\"s specification. |
| 31 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 32 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 33 | REINFORCED CEMENT CONCRETE WORK |
| 34 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 35 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 36 | Walls (any thickness) including attached pilasters, butteresses,plinth and string courses etc. |
| 37 | Suspended floors, roofs, landings, balconies and access platform. |
| 38 | Shelves (Cast in situ) |
| 39 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 40 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 41 | Stairs, (excluding landings) except spiral-staircases. |
| 42 | Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like |
| 43 | Edges of slabs and breaks in floors and walls |
| 44 | Under 20 cm wide |
| 45 | Weather shade, Chajjas, corbels etc., including edges. |
| 46 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additionalheight of 1 metre or part thereof (Plan area to be measured). |
| 47 | Suspended floors, roofs, landing, beams and balconies(Plan area to be measured) |
| 48 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 49 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 50 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 51 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 52 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 53 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairingstrength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. |
| 54 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cementcontent, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. |
| 55 | All works upto plinth level. |
| 56 | Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 57 | All works above plinth level upto floor V level. |
| 58 | Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 59 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
| 60 | BRICK WORK |
| 61 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 62 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 63 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 64 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 65 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 66 | Cement mortar 1:4 (1 cement :4 coarse sand) |
| 67 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry |
| 68 | Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). |
| 69 | MARBLE & GRANITE WORKS |
| 70 | Providing and fixing 18mm thick gang saw cut ( premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels. |
| 71 | Granite stone slab colour black, Cherry/Ruby red |
| 72 | Area of slab upto 0.50 sqm |
| 73 | Area of slab over 0.50 Sqm |
| 74 | Extra for fixing marble / granite stone over and above corresponding basic item, in facia and drops of width upto 150mm with epoxy resin baesd adhesive including cleaning etc. complete. |
| 75 | Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble /Granite/Stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edge etc. complete. |
| 76 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 77 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: |
| 78 | Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. |
| 79 | Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resincoating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. |
| 80 | The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to preventbi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approvedlaboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till thehanding over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium compositepanel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purposeof payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. |
| 81 | WOOD & PVC WORK |
| 82 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). |
| 83 | Second class teak wood |
| 84 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 85 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 86 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 87 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : |
| 88 | 2nd class teak wood |
| 89 | 50x12 mm |
| 90 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
| 91 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. |
| 92 | 1.0 mm thick |
| 93 | Hardware |
| 94 | Providing and fixing approved brand and manufacture of Stainless Steel Tower bolt 300 mm long with 10 mm dia ( TR 1210SS) along with necessary accessories and screws etc. complete in all respects as per manufacture ofrs\" specificatios & as directed by Engineer-in-charge. |
| 95 | Providing and approved brand and manufacture of Stainless Steel Door stopper - Door Mounted Hanging Type (DSHT) along with necessary accessories and screws etc. complete in all respects as per manufacture ofrs\" specificatios & as directed by Engineer-in-charge. |
| 96 | Providing and fixing approved brand and manufacture of Stainless Steel Door Buffer wall mounted 22 mm dia,75 mm long (DB (22) along with necessary accessories andscrews etc. complete in all respects as per manufacture ofrs\" specificatios & as directed by Engineer-in-charge. |
| 97 | Providing and fixing approved brand and manufacture of aluminium extruded section tubular type universal hydraulic door closer with Palmet Arm (DC 80 EXT (WP)SS) (having brand logo , embossed on the body, door weight upto 80 kg , 5 lacs Cycles Tested), with speed adjustment along with necessary accessories and screws etc. complete in all respects as per manufacture ofrs\" specificatios & as directed by Engineer-in-charge. |
| 98 | Door Handles and Locks |
| 99 | Providing and fixing approved brand and manufacture of Terza Design Mortice Lever handle On Plate (TER10SC) along with necessary accessories and screws etc. complete in all respects as per manufacture ofrs\" specificatios & as directed by Engineer-in-charge. |
| 100 | Providing and fixing approved brand and manufacture of Mortice Sash lock (ML100SS) with 85 mm CD & 50 mm Backset along with key cylinder fixing Option along with necessary accessories and screws etc. complete in all respects as per manufacture ofrs\" specificatios & as directed by Engineer-incharge. |
| 101 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 102 | 300x10 mm |
| 103 | 100x10 mm |
| 104 | Providing and fixing aluminium handles of approved make anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessry screws etc. complete. |
| 105 | 125 mm |
| 106 | 100 mm |
| 107 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows, Doors and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. With Upvc Snap beading. |
| 108 | STEEL WORK |
| 109 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 110 | Hot finished welded type tubes |
| 111 | Providing and fixing bolts including nuts and washers complete. |
| 112 | Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required |
| 113 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 114 | Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia polyamidePA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per direction of Engineer-in-charge. |
| 115 | 10 x 60 mm |
| 116 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 117 | FLOORING WORK |
| 118 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 119 | 40mm thick with 20mm nominal size stone aggregate. |
| 120 | Extra for pre finished nosing to treads of steps of marble / granite stone. |
| 121 | Extra for marble / granite stone flooring in treads of steps and risers using single length up to 2.00 metre. |
| 122 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 123 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 124 | Size of Tile 600x600 mm |
| 125 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. |
| 126 | Size of Tile 600x600 mm |
| 127 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slabover 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and asdirected by the Engineer-in-Charge. |
| 128 | Polished Granite stone slab colour of Black, Cherry/RubyRed or equivalent |
| 129 | ROOFING |
| 130 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase |
| 131 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 132 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, |
| 133 | with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section andperimeter channel with the help of dry wall screws of size 3.5 x 25mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitablyfixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : |
| 134 | 12.5 mm thick tapered edge gypsum moisture resistantboard |
| 135 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 136 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : |
| 137 | Ridges plain (500 - 600mm) |
| 138 | Gutter (600 mm over all girth) |
| 139 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 140 | GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. |
| 141 | FINISHING WORK |
| 142 | 12 mm cement plaster of mix : |
| 143 | 1:6 (1 cement: 6 coarse sand) |
| 144 | 15 mm cement plaster on rough side of single or half brick wall of mix : |
| 145 | 1:6 (1 cement: 6 coarse sand) |
| 146 | 20 mm cement plaster of mix : |
| 147 | 1:4 (1 cement: 4 coarse sand) |
| 148 | 6 mm cement plaster of mix : |
| 149 | 1:3 (1 cement: 3 fine sand) |
| 150 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. |
| 151 | Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 152 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : |
| 153 | New work (two or more coats) over and including waterthinnable priming coat with cement primer |
| 154 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 155 | Water thinnable cement primer. |
| 156 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : |
| 157 | Two or more coats on new work |
| 158 | Finishing walls with textured exterior paint of required shade : |
| 159 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 160 | Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : |
| 161 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm ofapproved brand or manufacture |
| 162 | Applying priming coat : |
| 163 | With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 164 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 165 | Two or more coats on new work |
| 166 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 167 | Providing and fixing Glass Reinforced Concrete (G.R.C) Screen at all levels & heights in approved size, pattern, design, thickness (minimum 35mm) and color. The Screens should be made from White Portland Cement, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber, Super Plasticizers, Polymers and U.V resistant Synthetic inorganic pigments should be used for pigmentation. The material casting should take place in Synthetic Rubber / FRP Mould. The fixing of Jali should be ‘Dry fixing’ i.e. to be done with MS/SS ‘L’ shaped Clamps, dash fasteners and pins etc complete as per site requirment and direction of Engineer-in-charge. |
| 168 | ALUMINIUM WORK:- |
| 169 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointedechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.Glazing and paneling to be paid for separately) : |
| 170 | For fixed portion. |
| 171 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 172 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 173 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 174 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge. |
| 175 | Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side. |
| 176 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): |
| 177 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) |
| 178 | With float glass panes of 8 mm thickness (weight notless than 20 kg/sqm) |
| 179 | Filling the gap in between aluminium frame and adjacent RCC/Brickwork/ Stone Work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge |
| 180 | Upto 5mm depth and 5mm width |
| 181 | WATER PROOFING |
| 182 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed withwater proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) |
| 183 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
| 184 | (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : |
| 185 | With average thickness of 120 mm and minimumthickness at khurra as 65 mm. |
| 186 | PLUMBING WORKS |
| 187 | SANITARY INSTALLATION |
| 188 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. |
| 189 | W.C. pan with ISI marked white solid plastic seat and lid |
| 190 | Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. |
| 191 | Providing and fixing Differecially abled toilets including Wash basin, Water closet,Cistern, grab bars & hand rails etc. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge.For physically handicap person consisting of; |
| 192 | Wall mounted WC Pan-01 no. withbuilt in Jet ofMake -1: Jaquar, Model No. VGSWHT81751P |
| 193 | Concealed Cistern Cistern-01 no.of Cera CAT no.Make - 1: Jaquar, Model No. VGSWHT81201 |
| 194 | Soft Close Seat Cover -01 no of Make 1: Jaquar Make Seat Cover of VGSWHT81751P |
| 195 | Wall hung Wash Basin -01 no of Make 1: Jaquar Model No. CNSWHT801 |
| 196 | Spatula Single lever Make 1: Jaquar, Model No. FLRCHR5033B |
| 197 | Wall mounted Grab bar 600 mm long - 2 nos of Make 1: Jaquar, Model No. WACWHTBR0600 |
| 198 | Wall mounted Hinged hand rail 750 x 100-01 no Make 1: Jaquar, Model No. WACWHTBG0800 |
| 199 | Bottle Trap Make 1: Jaquar, Model No. ALDCHR769L300X190 |
| 200 | Waste Coupling Make 1: Jaquar, Model No. ALDCHR705 |
| 201 | Stainless soap dish Make 1: Jaquar, Model No. AECESS1131 |
| 202 | Tissue paper holder Make 1: Jaquar, Model No. ACNCHR1151N |
| 203 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : |
| 204 | White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap |
| 205 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 206 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. |
| 207 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. |
| 208 | Granite Stone of approved shade |
| 209 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 210 | 510x1040 mm bowl depth 200 mm |
| 211 | Providing and fixing CP Brass Sink Faucet with Pipe Swinging Spout (Wall Mounted Model) with Connecting Legs & Wall Flanges of quality & make as approved by Engineer in charge. (a) 15 mm nominal dia. |
| 212 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 213 | Flexible pipe |
| 214 | 40 mm dia |
| 215 | Providing and fixing toilet paper holder : |
| 216 | C.P. brass |
| 217 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 218 | Providing and fixing CP Brass 32mm size bottle trap of approved quality & make and as per the direction of engineer in charge. |
| 219 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. |
| 220 | Providing and fixing Coat Hook. |
| 221 | Providing ,Fixing of straight / offset type flexible single body push fit type WC pan connector ofwith integral single mould sealing fins made of flexible EVA body to be fixed with manufacture supplied grease, including rubber bush / adaptor for use with C.I pipe as supplied with the pan connector. |
| 222 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 223 | Providing and fixing 8mm dia C.P./S.S. Jet with flexible tube upto 1meter long with S.S. Triangular plate to european type W.C. Of approved quality and make as approved by engineer in charge. |
| 224 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 225 | 15 mm nominal bore |
| 226 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore |
| 227 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length , 15 mm nominal bore |
| 228 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : |
| 229 | 100 mm diameter |
| 230 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 231 | 15 mm nominal bore |
| 232 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 233 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 234 | 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 235 | Supply,Installation, testing and commissioning ofWater Heater complete with heavy gauge hot and cold water flexible pipe connections, Nano polymer coated tank, 8 bar pressure ,of approved make complete with all necessary material as directed by Engineer - in - Charge. |
| 236 | 25-Litre Storage capacity |
| 237 | WATER SUPPLY |
| 238 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 239 | Concealed work, including cutting chases and making good the walls etc. |
| 240 | 15 mm nominal dia Pipes |
| 241 | 20 mm nominal dia Pipes |
| 242 | 25 mm nominal dia Pipes |
| 243 | 32 mm nominal dia Pipes |
| 244 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 245 | Internal work - Exposed on wall |
| 246 | 15 mm nominal dia Pipes |
| 247 | 20 mm nominal dia Pipes |
| 248 | 25 mm nominal dia Pipes |
| 249 | 32 mm nominal dia Pipes |
| 250 | 40 mm nominal dia Pipes |
| 251 | 50 mm nominal dia Pipes |
| 252 | Providing and fixing forged brass operated ball valve of full flow of superior quality having minimum working pressure of 16 kg/cm2. |
| 253 | 15 mm nominal bore |
| 254 | 20 mm nominal bore |
| 255 | 25 mm nominal bore |
| 256 | 32 mm nominal bore |
| 257 | 40 mm nominal bore |
| 258 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI markedcompletewithnuts,bolts,washers,gaskets conforming to IS 13095 of following sizes as required : |
| 259 | 50 mm nominal bore |
| 260 | Providing, fixing, testing and commissioning moterise Ball valve of following sizes, for filling of overhead tanks complete with high & low level switchs & pressure switch to control the valve. The level controller shalll be installed in over head tank. The level switch will close the valve when water level is high & open the valve when level is low in the tank. The system should be complete in all respect with accessories, 220V AC / 24 V DC, IP 67 water level control unit, Control Panel, copper control wiring in whether proof casing etc. |
| 261 | 50mm dia. |
| 262 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 263 | INTERNAL DRAINAGE SYSTEM |
| 264 | Providing and fixing soil, waste and vent pipes |
| 265 | Providing and fixing uPVC SWR Pipes class B (IS:13592) with all injection moulded fittings(door or plain) viz elbolws, bends, tees, junctions, shoe bends, couplers, offsets, cowel etc. complete including jointing with solvent cement including GI supports,cutting and making good the walls wherever required. Nothing extra will be paid for supports.(Vertical Soil, waste, balcony waste & rain water pipes) |
| 266 | 110 OD |
| 267 | Providing and fixing 100mm dia nominal bore uPVC pipe (Class-III)-IS:4985 inlet fitting approximately upto 300mm long above the trap with one or more 40 OD/ 50OD/63 OD/75OD holes for jointing waste pipes from waste appliances jointed and sealed with epoxy based sealant complete. |
| 268 | 32 OD uPVC pipe |
| 269 | 40 OD uPVC pipe |
| 270 | 63 OD uPVC pipe |
| 271 | Providing and fixing uPVC floor drain consisting of PVC reducing elbow 110 x 63mm (Grating and pvc pipe to be paid separately), complete as directed by the Project Manager. |
| 272 | Providing and fixing uPVC SWR P Trap with minimum 50mm water seal conforming to IS 13592 |
| 273 | 110 mm inlet & 110 mm outlet |
| 274 | Providing and fixing PVCCOP /FCO with suitable insert keys for opening as per approved sample, properly jointed to soil andwaste pipe asper requirement, complete as per instructions of the Engineer in charge. |
| 275 | For 110 mm dia pipe |
| 276 | Providing andfixing 125 mm dia,3 mm thick Stainless steel grating with framefor floor traps or drains of required pattern including cutting and making good the floors complete. |
| 277 | 125mm dia. |
| 278 | EXTERNAL SEWAGE WORK |
| 279 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, anddressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed,within a lead of 50 m : |
| 280 | All kinds of soil |
| 281 | Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia |
| 282 | Extra for Excavation trenches for pipes, cables etc. in all kind of soil for depth exceeding 1.5m but not exceding 3m (Rate is over corresponding basic item for depth up to 1.5m) |
| 283 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 Sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 284 | All kind of Soil |
| 285 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : |
| 286 | 150 mm diameter |
| 287 | 250 mm diameter |
| 288 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : |
| 289 | 150 mm diameter S.W. pipe |
| 290 | 250 mm diameter S.W. pipe |
| 291 | Providing and fixing square-mouth S.W.gully trapclass SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 292 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominalsize), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : |
| 293 | Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions,total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : |
| 294 | With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 295 | Extra for depth for manholes: |
| 296 | Size 90x80x90 cm |
| 297 | With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 298 | Constructing Brick Masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top with FPS bricksclass designation 75in cement mortar 1:4 (1 cement : 4 Coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand :6 graded stone aggregate 40mm nominal size) and making necessary channel in Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. |
| 299 | 0.91m deep with SFRC cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S:12592, total weight of cover and frame to be not less than 182Kg. fixed in cement concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete.(Excavation foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) |
| 300 | with common burnt clay F.P.S.(non module) brick of class designation 7.5 |
| 301 | Extra depth for circuler type manholes 0.91 m internal dia ( at bottom ) beyond 0.91m to 1.67 m . |
| 302 | with common burnt clay F.P.S.(non module) brick of class designation 7.5 |
| 303 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910, on 12 mm dia steel bar conforming to IS: 1786, having minimum cross section as 23 mmx25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 304 | 12 mm cement plaster finished with a floating coat of neat cement of mix : |
| 305 | 1:3 (1 cement: 3 fine sand) |
| 306 | ELECTRICAL WORKS |
| 307 | SUBHEAD- I:DISTRIBUTION BOARD |
| 308 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 309 | 8 way, Double door |
| 310 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) |
| 311 | 8 way (4+24) ,Double door |
| 312 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 313 | 40 amps |
| 314 | 63 amps |
| 315 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 316 | 63 amps |
| 317 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 318 | Single pole |
| 319 | Supplying and fixing following rating, double pole, single phase and neutral, 240 volts, residual current circuit breaker ( RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required. |
| 320 | 63 amps |
| 321 | Supplying and fixing following rating, four pole, three phase and neutral, 415 volts, residual current circuit breaker ( RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc as required. |
| 322 | 63 amps |
| 323 | SUB-HEAD - II: INTERNAL WIRING |
| 324 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 325 | Group - A |
| 326 | Group – C |
| 327 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the pointwith 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 328 | Group - A |
| 329 | Group - C |
| 330 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 331 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 332 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 333 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 334 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required |
| 335 | 2 X 10 sq. mm + 1 X 10 sq. mm earth wire |
| 336 | 4 x 10 sq.mm + 2 x 10sq.mm. earth wire |
| 337 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in residential buildings). |
| 338 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 339 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 340 | Supplying and fixing of call bell / buzzer suitable for single phase,230 volt completeas required. |
| 341 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required |
| 342 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.Make:KEI,Worldcab,RR Kable,Bonton |
| 343 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.Make:KEI,Worldcab,RR Kable,Bonton |
| 344 | SUB-HEAD III - FANS & LIGHT FIXTURES: |
| 345 | Supplying , fixing, testing and commissioning of 100W Chandlier Light with high efficiency white reflector and high transmissive diffuser ,fitting complete with, holder, electronic driver, heat sink and LED (less than 10% THD), low depth with die cast aluminium housing LEDwith CRI >70, 6500K, includingdriver etc., |
| 346 | Supplying , fixing, testing and commissioning of surface/ recessed type 12W LED down-lighter with high efficiency white reflector and high transmissive diffuser ,fitting complete with, holder, electronic driver, heat sink and LED (less than 10% THD), low depth with die cast aluminium housing LEDwith CRI >70, 6500K, includingdriver etc., |
| 347 | Supplying, fixing, testing and commissioning of bracket light 12/15W LED luminaire complete with electronic ballast, lockable holders, shade cover including connection etc. |
| 348 | Supplying , fixing, testing and commissioning of surface/ recessed type 18W LED down-lighter with high efficiency white reflector and high transmissive diffuser ,fitting complete with, holder, electronic driver, heat sink and LED (less than 10% THD), low depth with die cast aluminium housing LEDwith CRI >70, 6500K, includingdriver etc. |
| 349 | Supplying, fixing, testing and commissioning of mirror light5/4W LED min 350 lumens, 1 feet length, 6500 Kcomplete with electronic driver, lockable holders and LED lamp including connection etc. |
| 350 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.00, Air delivery minimum 210 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 351 | Supplying, fixing, testing and commissioning of Wall mounted luminairefor 18W/20W LED 4 feet fixture with extrudedthermal polycarbonate housing fixture should be of minimum 1800 lumens (6500 KELVIN) suitable for operation on 230 volt 50 Hz,Single Phase AC supply with electronic driver and all accessories complete for ceiling/wall/ Surface including wiring, connection with 1.5 sq.mm FRLS PVC insulatedcopper conductor single corecable including earthing etc. |
| 352 | Supplying, fixing, testing and commissioning of following size exhaust/ fresh air fan complete with gravity louver and connection with 3 core flexible wire as required. |
| 353 | a) 300mm 1400 RPM Heavy duty Metal exhaust fan Havells make model: Turbo Force SP or equivalent preferred makes. |
| 354 | SITC of recess mounted LED luminaire (2X2) min 36W made CRCA housing having powder coating with high efficiency PET/Prismatic diffuser for homogeneous light distribution. Fixture should have minimum efficacy at System level (Not Chip Level) =125 lumens/watt and a minimum system lumen output of >3750 lumens. |
| 355 | SUB HEAD - IV : SERVER, DATA & NETWORKING |
| 356 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 357 | Telephone socket outlet |
| 358 | TV antenna socket outlet |
| 359 | Supplying and fixing of RJ-11/RJ 45(Both Twin socket)I/O Telephone outlet with shutters along with suitable base plate,key stone and surface/concealed back boxes of adequate module size, etc comple in all respect. |
| 360 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. |
| 361 | 1 or 2 Module (75mmX75mm) |
| 362 | CABLING AND CONDUITING |
| 363 | Supplying and drawing following pair 0.5 mm dia FRLS PVCinsulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 364 | 1 Pair |
| 365 | 2 Pair |
| 366 | 3 Pair |
| 367 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 368 | 1 run of cable |
| 369 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 370 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 371 | 25 mm |
| 372 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required |
| 373 | 25 mm |
| 374 | SUB HEAD - VI :ELECTRICAL PANEL |
| 375 | MAIN PANEL- |
| 376 | INCOMER |
| 377 | 1 No. 100amps 4P MCCB(10KA) with thermal Magnetic release (PRTM) with Class-C transient voltage surge suppression device suitable for 3 phases as per specifications. |
| 378 | 1 No.100 amps ATS |
| 379 | METERING & INDICATION for each Incomer |
| 380 | 1 set of R,Y,B phase indicating lamps |
| 381 | Multifunction digital meter (consisting of Voltage, Current, Frequency, PF, kWh, kVA, harmonics upto 15th order & %THD) with RS-485 Port. |
| 382 | Sets of 100/5A, CL-1, 15VA CTs for measuring. |
| 383 | Sets of phase indicating lamp with 2A control MCBs. |
| 384 | BUS-BAR |
| 385 | 125 A TPN Aluminium Bus Bar with colour coded PVC Sleeves |
| 386 | OUTGOINGS |
| 387 | 3 Nos. 63 Amp TPN MCCB |
| 388 | 3 Nos. 40 Amp TPN MCB |
| 389 | 3 Nos. 40 Amp DP MCB |
| 390 | Main Panel as described above |
| 391 | SEPTIC TANL & SOAK PIT WORKS |
| 392 | EARTH WORKS |
| 393 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth,lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. |
| 394 | All kinds of soil. |
| 395 | Extra for every additional lift of 1.5 m or part thereof in. |
| 396 | All kinds of soils |
| 397 | 1.5m to 3.0m |
| 398 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 399 | Carriage of Earth by mechanical transport including loading, unloading and Stacking including royalty & carriage up to 5 KMcomplete. |
| 400 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 401 | CONCRETEWORKS |
| 402 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 403 | 1:4:8 (1 cement : 4 coarse sand (Zone-III) derived from natural sources : 8 graded stone aggregate 40mm nominal size derived from natural sources). |
| 404 | Centering and shuttering including strutting, propping etc. and removal of form work for : |
| 405 | Foundations, footings, bases for columns |
| 406 | REINFORCED CEMENT CONCRETE WORK |
| 407 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 408 | Foundations, footings, bases of columns, etc. for mass concrete. |
| 409 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 410 | Suspended floors, roofs, landings, balconies and access platform. |
| 411 | Edges of slabs and breaks in floors and walls |
| 412 | Under 20 cm wide |
| 413 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth & above plinthlevel. |
| 414 | Thermo-Mechanically Treated bars. |
| 415 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairingstrength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. |
| 416 | Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cementcontent, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. |
| 417 | All works upto plinth level. |
| 418 | Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 419 | STEEL WORK |
| 420 | Steel work welded in built up sections/ framed work, including cutting,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 421 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 422 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : |
| 423 | With 20x20 mm square bar |
| 424 | Supplying and fixing C.I. cover without frame for manholes : |
| 425 | 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg |
| 426 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 427 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 428 | FINISHING WORK |
| 429 | 12 mm cement plaster of mix : |
| 430 | 1:6 (1 cement: 6 coarse sand) |
| 431 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge. |
| 432 | 6mm cement plaster of mix : |
| 433 | 1:3 (1 cement: 3 fine sand) |
| 434 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. |
| 435 | Finishing walls with textured exterior paint of required shade : |
| 436 | New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 437 | WATER PROOFING |
| 438 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick |
| 439 | Extra for covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation. |
| 440 | Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage. |
| 441 | For vertical surface two coats @0.70 kg per sqm |
| 442 | For horizontal surface one coat @1.10 kg per sqm. |
| 443 | Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/ expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete : |
| 444 | Serrated with central bulb (225 mm wide, 8-11 mm thick) |