Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 17-04-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 24-04-2023 |
| 2 | 13-04-2023 | Other Corrigendum2 | Other | 17-04-2023 |
| 3 | 13-04-2023 | Date Corrigendum3 | Date | 17-04-2023 |
| 4 | 06-04-2023 | Other Corrigendum | Other | 13-04-2023 |
| 5 | 06-04-2023 | BOQ Corrigendum | BOQ | 13-04-2023 |
| 6 | 05-04-2023 | Date Corrigendum2 | Date | 13-04-2023 |
| 7 | 31-03-2023 | Date Corrigendum | Date | 12-04-2023 |
| Sl. No. | Item Description |
| 1 | Demolition of Unreinforced Cement Concrete in ground floors and Pavings not exceeding 15cm thick [below or above ground level] and removing rubbish to a distance not exceedingcomplete all as specified and as directed. |
| 2 | Demolition of Brick / Stone Masonry built in Cement Mortar including all quoins arches pillars etc and removing rubbish to a distance not exceeding 1.50 KM complete all as specified and as directed. |
| 3 | Taking down Chowkats or frames with shutters [without taking off shutter from the frame] exceeding 1.5 Sq.m but not exceeding 4.00 Sq.m each and removing to store complete all as specified and as directed. |
| 4 | Taking down Eaves Gutters and Rainwater Pipes [any size or pattern], including all fittings, heads, shoes, bends, swan-necks, etc. from any height complete all as specified and as directed. |
| 5 | Dismantling of Floor, Hearth or Wall Tiling of any description including Cement Mortar bedding [but not backing] and removing serviceable tiles to the stores andremoving rubbish / debris to a distance not exceeding 1.50 KM complete all as specified and as directed. |
| 6 | Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces, ceiling surfacesetc including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance not exceeding 1.5 KM complete all as specified and as directed. |
| 7 | Taking down or up steel tubing and connections including Taps / Valves for 15 mm bore of pipe complete all as specified and as directed. |
| 8 | Taking down or up steel tubing and connections including Taps / Valves for 20 mm bore of pipe complete all as specified and as directed. |
| 9 | Excavation in post holes each not exceeding 0.5 Cu.m, getting out in Soft / Loose soil, including returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm thick, watering and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and as directed. |
| 10 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep and getting out in Soft / Loose soil complete all as specified and as directed. |
| 11 | Removal of excavated material [Soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 12 | M & L for PCC 1:3:6, Type C-2, using 40mm graded stone aggregate as in Foundation, Fillings, Mass concrete, Footings etc complete all as specified and as directed. |
| 13 | M & L for Hardcore of gauge not exceeding 63mm of broken stones or boulders, deposited, spread and levelled in layers not exceeding15 cm thick watered and rammed to true surface complete all as specified. |
| 14 | M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed. |
| 15 | M & L for brick work with Fly Ash bricks, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed. |
| 16 | M & L for Powder coated aluminium sections [Minimum 50 Micron thick] of approved colour for Doors, Windows, Ventilators, Partitions with frame and shutters fully or partly glazed, sliding / openable including necessary jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts, stainless steel friction hinges, locking arrangementsetc., complete all as specified and as directed.Notes:[a]The size of aluminium sections shall be all as specified in relevant IS code and MES Schedule Part - I. [b] Panel inserts such as Glass / Particle board / Gauze shall be measured and paid separately at supply only rates.[c] Weight of aluminium sections shall only be accounted for payment purpose. Weight of aluminium Handles, Butt Hinges & Tower Bolts shall not be accounted for payment purpose. [d] The unit rate quoted shall be deemed to include for cost of jointing cleats, glazing clips, rubber beading, neoprene packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as handles, aluminium butt hinges, aluminium tower bolts, stainless steel friction hinges, locking arrangementsetc., and fixing only of panel inserts ofglass / particle board / gauge etc. |
| 17 | S & F Factory made UPVC Sliding Window, Three Track, White Colour of area not exceeding 2.0 Sq.m, made of extruded profiles with wall thickness of 2.3mm±0.2mm, Window profile with hollow section with multi chamber, Frame of size 112mm X 45mm, Sliding Sash of size 42mm X 67mm, Sliding Mesh Sash of size 42mm X 57mm, Sliding Interlock [One vertical length in each shutter]of size 45.50mm X 28mm, Glazing Bead of size 24.50mm X 16mm shall be mitred cut and fusion welded at all corners, including drilling holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM Gasket, 1.2mm±0.2mm thick Galvanized Steel Frame of size 30mm x 12mm, 2 Nos, Sliding Sash of size 30mm x 18mm, Sliding Mesh Sash of size 26mm x 10mm, profile to be inserted in required profile, frame shall be fixed to the wall with 8mm X 100mm long fasteners, complete all as specified and as per Manufacturer instructions. Note:(i) The unit rate quoted by the contractor includes cost of fixing of grills, galss panes and wire cloths including all other connected accessories. (ii) The Grills, Glass Panes and wire cloths shall be measured and paid saperately at supply only rates under relavent Items of this Schedule.(iii) The size of UPVC sections specified in the description of item is minimum requirement, if the same size of section is not available, next higher size shall be provided by the contractor without any extra cost to the Department. |
| 18 | Supply only 18mm thick, Prelaminated Particle Board, One Side Decorative Choice Lamination and other side Balancing White, Medium Density, Interior Gradecomplete all as specified and as directed. |
| 19 | Supply only Powder Coated Aluminium Deco Grill of Model / Design No. DG 104 (7mmx4.2mm), including Powder Coated Aluminium Channel of size 30 X 12 X 1.5mm for fixing Deco Grill complete all as specified and as directed. |
| 20 | Supply only 5mm thick Sheet Glass ordinary quality in squares not exceeding 0.5 Sq.m in each pane complete all as specified and as directed. |
| 21 | Supply onlyStainless steel wire cloth / mesh with average aperture not exceeding 1.40 mm and dia of wire 0.36 mm complete all as specified and as directed. |
| 22 | S & F Solid PVC door frame of size 50mmX47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening of Sintex ot its equivalent make as approved by Accepting Officer complete all as specified and as directed. |
| 23 | S & F Factory Made Solid PVC Moulded Door Shutter, with Particle Board Core, 28 to 30mm thick [Stiles], with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing shown on Serial Page No. 161 of MES Schedule Part - II complete all as specified and as directed. |
| 24 | S & F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame complete all as specified and directed. |
| 25 | S & F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications complete all as specified and directed. |
| 26 | S & F 12mm thick Toughened Glass Door, Rimless swing type, fixed with frosted film or Logo of any type/ design on one side as approved by GE complete including grinding the edges complete all as specified and as directed.Note: The rate quoted shall be inclusive of provision of suitable SS locking arrangement and 300mm long Handles made with 25mm dia Stainless Steel pipe of Grade AISI 304 on both sides for each shutter. |
| 27 | S & F Double Action Floor Spring Hydraulically Regulated made of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governingpivot made of brass, other parts made of mild steel heavy duty complete all as specified and as directed. |
| 28 | S & F Second Class Hard Wood Chowkats and Frames, segmental worked from the solid,wrought, framed, rounded or chamfered, put together with glue, pinned at joints complete all as specified and directed. |
| 29 | S & F 40 mm thick Factory made Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed. |
| 30 | S & F 100 mm size, Butt hinges, Stainless Steel, with SS hinge pin including fixtures complete all as specified and as directed. |
| 31 | S & F Aluminium anodised barrel Tower Bolt of size 150 mm size of extruded section complete all as specified and as directed. |
| 32 | S & F Aluminium anodised Handle, of extruded section Fabricated Type of size 100mm long complete all as specified and as directed. |
| 33 | S & F Aluminium alloy anodised Sliding Door Bolt with hasp and staple [Bolt Type] of size 300 mm and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed. |
| 34 | S & F Venetian Blinds, Vertical Louvers type PVC Blinds, 100mm wide of approved Texture / Colour, opening from the centre or from either side of the window, mounted on colour coordinated tracks made with powder coated aluminium sections to blend with the vertical blades including all accessories of Vista Levelor Brand or equivalent approved make complete all as specified and as directed. |
| 35 | S & F Rolled Mild Steel work conforming to Fe 410-W, Grade-E- 250, Quality-A as in Roof Trusses [framed], trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing [Beam, tee, angle, channel or flat sections] including distance pieces, cleats etc complete all as specified and as directed. |
| 36 | S & F pre-painted Galvalume steel sheets of Trapezoidal profile having pitch 190mm, depth 29mm or Tiled Profile and thickness 0.50mm [Galvalume base-PPGL trapezoidal profile sheets], having tensile strength of 550 Mpa, fixed with aluminium self tapping screws, neoprene and EPDM washers of suitable size in roof covering complete all as specified and as directed. Note: Overlap shall be provided as specified by the manufacturer. |
| 37 | M & L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry with 3.0 KG of cement per Sq.m area, rendering 10mm thickin cement mortar 1:3 on concrete surfaces finished even and smooth without using extra cementincluding mixing of water proofing compound of approved make as per manufacturers instructions for levelling the surface smooth to receive the water proofing membrane, priming the surface with a coat of cold applied bituminous primer @ 0.50 KG per Sq.m, applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m, laying Polymeric water proofing membrane of weight not less than 3.00 Kg per Sq.m reinforced with polyester non-woven fabric of weight notless than 150 Grams per Sq.m, by torch application with side over lap of 100mm & end over lap of 150mm & tucked into the chases on vertical surfaces by thermo fusion including applying a coat of Blown Bitumen of grade 85/25 @ 1.2 Kg per Sq.m on top and finished with a coat of bituminous aluminium paint @ 100 grams per Sq.m on top for water proofing treatment complete including taking down existing Roof Treatment of any description and removing rubbish to a distance exceeding 1.5 KM but not exceeding 15.0 KM complete all as specified and as directed.Note: Water proofing compound will be measured and paid separately. |
| 38 | S & F False Ceiling Frame Work using Anodised Aluminium snap grid frame work of 600 X 600 mm panel size for false ceiling with Aluminium \"T\" section of size 38 X 25 X 1.50 mm thick for Main Runners, 25 X 25 X 1.5 mm thick for Cross Runners and Angle of size 25 X 25 X 1.50 mm thick along the Walls suspended with and including 4 mm dia, Galvanized mild steel wire as in suspenders of ceiling members fixed in proper position including fixing 16mm thick Mineral Fibre Board of size 600 X 600 X 16mm of make Armstrong [Model No. DUNE RH99 or equivalent approved makes as specified here in after], Premium sand textured finish, having humidity resistance of RH99 for false ceiling, fixed to ceiling section with 25 mm dry wall screws at 230 mm centres and including dismantling of Wall & Ceiling Boards [Fibre / Pulp / Insulation etc] of any description or Insulation Boards / Slabs / Blankets including cover fillets complete all as specified. |
| 39 | Material and lablour for providing self levelling Electro Static Dissipative [ESD] hygenic Epoxy flooring comprising of the following al as specified andas direced and as per manufacturer\"s instructions:-[a] Re-profile the existing concrete floor surfaces including cut open all anchor grooves along floor topping termination points and alround the columns, all cracks in the floor concrete including all other joints to a depth not less than 20mm including preparation of existing concrete substrate surfaces mechanically using sand blasting, shot blasting or scarifier including wire brushing as required and removing all foreign matter, dust and debris etc by industrial vacuum cleaner followed by thorough water wash to obtain clean and sound substrate to ensure maximum bonding between the substrate and coating system complete all as specified as directed and as per manufacturer’s instructions.Note: Epoxy mortar screed as in preparatory work to fill the cracks/ grooves/ joints shall be measured and paid sepaerately under respective item of this Schedule. [b] Providing two component, high solid, epoxy resin based floor primer, 150 micron thick spread uniformly over the prepared substrate as a bond coat between the subsequent layer.[c] Providing 2mm thick three component, high strength heavy duty epoxy based self leveling screed. [d] Providing Copper strip of 25mm width placed over the floor with not les than 2M x 2M pattern including copper tapes.[e] Providing two component, conductive epoxy primer for ESD flooring system, 75 micron thick, applied uniformly over the screed and copper strips/ tapes as a conductive bond coat after the copper grid is laid.[f] Providing 1.5mm thick self levelling epoxy based electrostatic dissipative hygienic floor coating. |
| 40 | Note: The epoxy flooring and allied works catered vide item Nos. ____ & ____ of this BoQ shall be got executed through the Authorised Applicator of the Manufacturer and under the guidance of Manufacturer of Epoxy Flooring.Make: M/s. Fosroc Chemicals India [P] Ltd. or M/s. Sika India Pvt. Ltd. or M/s. STP Ltd. or M/s. Choksey Chemicals Pvt. Ltd. or M/s Bostik India Pvt. Ltd. or M/s. BASF India Ltd./ M/s Asian Paints Ltd. |
| 41 | M&L for non shrinkable high strength 3 component epoxy mortar screed mixed in the ratio of 2 parts of resin: 1 part of hardener: 18 parts of fine silica sand/ graded quartz , minimum 50mm thick,laid on floors, joints and other areas over a coat of epoxy primer andfinishing the surface to even and plain using suitable means to remove all imperfections, trowel marks and entrapped air complete all as specified as directed and as per manufacturer’s instructions. |
| 42 | M & L for 75 mm thick, PCC 1:4:8, Type D-2, using 40mm graded stone aggregate as in Sub base for flooring complete all as specified and as directed. |
| 43 | M & L for 25 mm average thick PCC 1:2:4, Type B-0, using 12.5mm graded aggregate as in as in Sub base for flooring etc.finishing the top surface even complete all as specified and as directed. |
| 44 | M & L for 40 mm thick PCC 1:2:4, Type B-1, using 20mm graded stone aggregate as in sub base complete all as specified and as directed. |
| 45 | M & L for Vitrified Tiles, Double Charged, Coloured, Premium Quality, of size not exceeding 0.36 Sq.m, 10 mm thick as in Floors, set and jointed in cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:6 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE. |
| 46 | M & L for Vitrified Tiles, Double Charged, Coloured, Premium Quality, of size not exceeding 0.36 Sq.m, 10 mm thick as in Floors, set and jointed in cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 10 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE. |
| 47 | M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.18 Sq.m and not exceeding 0.36 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE. |
| 48 | M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.06 Sq.m and not exceeding 0.11 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE. |
| 49 | M & L for Joint Free Glazed Ceramic Tiles, Edge Cut, Concept Type, Coloured, Premium Quality, of size 450 mm X 300 mm, 7 to 8 mm thick as in Vertical Surfaces such as Skirting, Dado etc set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 15mm thick in Cement Mortar 1:4 complete all as specified and as directed. The colour / shade / design of tiles shall be as approved by GE. |
| 50 | M & L for Glazed Polish finished coloured Chequered Cement Concrete Tiles of thickness 23 to 25mm, made with M-25 Grade Precast Cement Concrete, Hydraulically pressed of size not less than 300 X 300 mm, of approved shape, colour and pattern, set, jointed and pointed in neat cement slurry to match including screed bed or bedding layer of mortar 20 mm thick in Cement Mortar 1:4 complete all as specified and as directed. |
| 51 | M & L for Inter Locking Paving Blocks of 80mm thick, made with M40 Grade cement concrete using 20 mm graded stone aggregate, Hydraulically pressed of approved colour and pattern, shape and size conforming to IS - 15658 set in floors complete all as specified and directed. |
| 52 | M & L for rendering 5 mm thick in Cement Mortar 1:3 on fair faces of concrete surface of ceiling surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 53 | M & L for rendering to brick / concrete surfaces, 10 mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 54 | M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:4, surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 55 | M & L for rendering to brick / concrete surfaces, 15 mm thick in Cement Mortar 1:4, including mixing water proofing compound as per manufacturers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and as directed.Note:Water proofing compoundwill be measured and paid separately. |
| 56 | Supply only integral water proofing compound [ISI marked] of approved make. |
| 57 | M & L for Complete removal of existing treatment of any description on wallsurfaces by using vaccume based sanding machine, removal of nails and applying upto 1mm thick Cement based Wall Care Putty on walls by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of Acrylic Washable Distemper by using auto roller/ airless sprayer over one of alkali resistant primer on wallsurfaces complete all as specified and as directed.Note:- The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicatorsbefore commencement of the work to GE for approval. |
| 58 | M & L for preparing newly plastered Wall surfaces by using vaccume based sanding machineandapplying two coats of Acrylic washable Distemper by using auto roller/airless sprayer, over a coat of alkali resistant primer over two or more coats of Cement based Wall Care Putty on walls by using multipurpose mixture for proper mixing of putty and putty sprayer for application of putty including rubbing with sand paper to obtain a smooth surfacecomplete all as specified and as directed.Note:- The contractor shall carryout Distempering & allied works under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Distempering & allied works through their authorised applicatorsbefore commencement of the work to GE for approval. |
| 59 | M & L for Two coats of Cement Based paint over a coat of Alkali Resistant Primer by using auto roller/ airless sprayer on newly plastered Walls/ ceilings, pillasters, bands, borders, soffits of chajjas and projections including necessary preparation of surfaces by using vaccume based sanding machine complete all as specified and as directed. |
| 60 | M & L for Complete removal of existing treatment of any description on walls surfaces by using vaccume based sanding machine, removal of nails including rubbing with sand paper to obtain a smooth surfaces and applying Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] by using auto roller/ airless sprayer over a Coat of Weather Proof Exterior Primer of same manufacturer as that of paint on walls complete all as specified and as directed.Note:- The contractor shall carryout Weather proof Exterior Emulsion Painting under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Weather proof Exterior Emulsion Painting through their authorised applicatorsbefore commencement of the work to GE for approval. |
| 61 | M & L for Two coats of Weather Proof Exterior Emulsion Paint [100% Acrylic] by using auto roller/ airless sprayer over a Coat of Exterior Primer of same manufacturer as that of paint on newly plastered walls/ ceiling, pillasters, bands, borders, soffits of chajjas and projections including necessary preparation of surfaces by using vaccume based sanding machine complete all as specified and as directed.Note:- The contractor shall carryout Weather proof Exterior Emulsion Painting under subject work through the Authorised Applicator of the manufacturer only. The lowest bidder shall submit MoU from manufacturer to provide technical support and trained persons for carrying out Weather proof Exterior Emulsion Painting through their authorised applicatorsbefore commencement of the work to GE for approval. |
| 62 | M & L for two coats of synthetic enamel paint over one coat of pink primer to newly untreated wooden surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed. |
| 63 | M & L for one coat of Synthetic Enamel paint on old painted wooden surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed. |
| 64 | M & L for two coats of Synthetic Enamel paint over one coat of Red Oxide / Zinc Chrome Primer on new steel surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed. |
| 65 | M & L for one coat of Synthetic Enamel paint on old painted steel surfaces over 10cm width or girth including preparation of surfaces complete all as specified and as directed. |
| 66 | S & F CPVC Pipes 20 mm outer diameter & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, including taking down of existing unserviceable GI pipes complete all as specified and as directed. |
| 67 | S & F CPVC Pipes 16 mm outer diameter SDR 11 & Plain CPVC SDR 11 Fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc fixed to walls, ceiling or laid on floors including testing, including taking down of existing unserviceable GI pipes complete all as specified and as directed. |
| 68 | S & F in repairs Vitreous China Wash Down Water Closet [Pedestal pattern], White, including 10 Litres capacity, PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of lowor high density of PVC, 32mm dia, PVC Connection of 15mm Bore and 600mm long with PTMTcheck nut and union etc. including brackets and connections to pipe and flush pipe including plastic water closet seat back closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and \"P\" or \"S\" trap complete all as specified and as directed. |
| 69 | S & F in repairs Vitreous China Ware Wash Hand Basin, White, Flat Back of size 550 mm X 400 mm including 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, cutting for and pinning in ends of brackets or erecting strand, 32mm bore PVC flexible Waste Pipe, PVC Connection of 15mm Bore and 600mm long with PTMT check nut and union etc. complete all as specified and as directed. |
| 70 | S & F in repairs Vitreous china urinal, bowl type, flat back, white of size 465 X 355 X 265mm, complete including providing and fixing plugs, bedding urinal against wall in cement mortar [1:2], securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, including 32mm dia brass chromium plated waste fittings with long screw shanks and fly nuts, flange end bedded in red led cement and other end fixed, rubber plug with rings including CI Brackets, 32mm bore PVC flexible waste pipe, grating and union for discharge pipe, CP screws PVC Connection of PTMT, Urinal spreader of PTMT any colour for fixing with 15 mm dia pipe [Minimum weight 60 Grams]etc. complete all as specified and as directed. |
| 71 | S & F in repairs Pillar Taps, cast copper alloy, Chromium Plated, Fancy Type, 15 mm dia, with capstan head, screwed down high pressure with or with out lettered \"Hot\" or \"Cold\" with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and as directed. |
| 72 | S & F in repairs Bib Taps, 15 mm dia, Brass Chromium Plated, Fancy Type with crutch or butterfly handle, screwed down for iron pipe and fixed etc. complete all as specified and as directed. |
| 73 | S & F in repairs Stop Valves, 15 mm dia, cast copper alloy with capstan head, Chromium Plated, Fancy Type, screwed down high pressure with crutch or butterfly handle screwed for iron pipe etc complete all as specified and as directed. |
| 74 | S & F in repairs 600 mm X 450 mm Bevelled Edge Mirror of selected quality glass, 5 mm thick, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with CP brass screws and cup washers complete all as specified and as directed. |
| 75 | S & F PTMT Grating Dome, 100 mm dia [Minimum weight 25 Grams] without waste hole or with waste hole to insert waste pipe complete all as specified and directed. |
| 76 | S & F 110mm bore PVC [SWR] pipes single socketed, in any length with rubber ring joints, fixed to walls including necessary brackets, clamps complete all as specified and as directed. |
| 77 | S & F 110 mm bore PVC [SWR] Bends of any radius with Access Door including jointing with solvent cement complete all as specified and as directed. |
| 78 | S & F 110 mm bore PVC [SWR] Junction Single [Single \"T\"] equal or unequalwith Access Door including jointing with solvent cement complete all as specified and as directed. |
| 79 | S & F 110 mm bore PVC [SWR] Vent Cowl including jointing with solvent cement complete all as specified and as directed. |
| 80 | M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, Two runs, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type and Metal GI Flush Box of suitable size and thickness including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Pointincluding taking down existing unserviceable point wiring of any description and making good disturbed surfaces complete all as specified and as directed.Note:-The quoted rate are deemed to be includingall the cost of cutting,chasing,cementing work and making all the disturbed surfaces of wall/ceiling good to match the existing wall/ceiling along with same colour. |
| 81 | All as per Serial Item No. 79 above but One 3 Pin Socket Outlet 5 Amps on Independent Board complete all as specified. |
| 82 | All as per Serial Item No. 79 above but One 3 Pin Socket Outlet 5 Amps on same Board complete all as specified. |
| 83 | All as per Serial Item No. 79 above but one 3 Pin Socket Outlet 15 Amps on independent board, with 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLS grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor complete all as specified and as directed. |
| 84 | Taking down existing unserviceable Sub main wiring of any dscription and size from any position alongwith wooden battens / conduits / casing cappingincluding making good the disturbed surfaces to match with the adjacent surfaces complete all as specified and as directed. |
| 85 | Cutting chases, pinning in, making good to facings where required and pointing in Cement Mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10 cm girth brick walls complete all as specified and as directed. |
| 86 | M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including stove enamel steel Conduit 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 3 runs of 6 Sq.mm & one run of 20 mm dia stove enamelled Conduit will be measured as one unit. |
| 87 | M & L for Sub main wiring with 2 runs of single core 6 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 6 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 3 runs of 6 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit. |
| 88 | M & L for Sub main wiring with 2 runs of single core 4 Sq.mm Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade, ISI Marked, drawing through and including heavy duty PVC Conduit, 25 mm dia with all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type including One run of 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, FRLS Grade earth continuity conductor complete all as specified and as directed. Note: 3 runs of 4 Sq.mm & one run of 25 mm dia PVC Conduit will be measured as one unit. |
| 89 | S & F Switch, Modular Type, One Module, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed. |
| 90 | S & F Switch Modular type, one module, Single pole, one way, 16 Amps, 230 Volts complete all as specified and as directed. |
| 91 | S & F Socket Outlet, 3 Pin, 6 Amps, Modular Type, Two Modules, 230 Volts, complete all as specified and as directed. |
| 92 | S & F Socket Outlet, 3 pin, 16 Amps and 3 pin, 6 Amps, Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed. |
| 93 | S & F Flame proof Switch Socket & Plug combination in LM6 cable termination box in LM6, 16 Amps, 250 Volts, 2P + Earth complete all as specified and as directed. |
| 94 | S & F Bell Push, Modular Type, One Module, Single Pole, One Way, 6 Amps, 230 Volts complete all as specified and as directed. |
| 95 | S & F Bell, Ding Dong / Multi Music Type, AC, 230 Volts, Single Pole complete all as specified and as directed. |
| 96 | S & F Ceiling Rose, PVC Body, 65 X 50 mm, Three Terminals, 230 Volts complete all as specified and as directed. |
| 97 | S & F SPNsheet metal enclosure, Modular type, with two pin and earth plug and socket, with andincluding One MCB, SP, 20 Amps, 10 KA, C curve, 240 Volts complete all as specified and as directed. |
| 98 | S & F in repairsSPNsheet metal enclosure, Modular type, with two pin and earth plug and socket, with andincluding One MCB, SP, 20 Amps, 10 KA, C curve, 240 Volts complete all as specified and as directed. |
| 99 | S & F MCCB DB, VTPN, 4 Way, 415 Volts with DIN Channel, N3 Frame, Double Door with 160 Amps rated bus bar suitable for mounting MCBs and provision for MCCB as incomer complete all as specified and as directed. |
| 100 | S & FMCCB415 V , 16 KA, 4 Pole, 100 Amps capacity complete all as specified and as directed. |
| 101 | S & F in repairs MCB DB, TPN, 4 Way, 415 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wall including making good disturbed surfaces complete all as specified and as directed. |
| 102 | S & F Flame ProofMCB DB, SPN, 4 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs flush mounted with wall including making good disturbed surfaces complete all as specified and as directed. |
| 103 | S & FMCB DB, SPN, 12 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs complete all as specified and as directed. |
| 104 | S & Fin repairsMCB DB, SPN, 12 Way, 240 Volts, with DIN Channel, Double Door with 200 Amps rated bus bar suitable for mounting MCBs complete all as specified and as directed. |
| 105 | S & F MCB, SP, 6 to 32 Amps, 10 KA, C Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed. |
| 106 | S & F MCB, TPN, 40-63 Amps, 10 KA, C Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed. |
| 107 | S & F MCB, SPN, 6 to 32 Amps, 10 KA, C Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed. |
| 108 | S & F RCBO, 4P, 100mA, 40/ 63A , 415 Volts, complete all as specified and directed. |
| 109 | S & F RCBO, DP 30mA, 6 to 32A , 230 Volt, complete all as specified and directed. |
| 110 | S & F RCBO, DP 30mA, 40/ 63 A , 230 Volt, complete all as specified and directed. |
| 111 | Fixing only in repairsexisting MCB distribution boards of any description and ways including rectifying the wiring cables making good the surfaces to match with the adjaccent surfaces complete all as specified and as directed. |
| 112 | S & F Square recessed mounted Flat Panel LED Ceiling Light suitable for fixing in 2\" X 2\" Grid False Ceiling of not less than 3600 Lumens output,, 6500 K, with high transmitive diffuser for soft-light and glare free symmetrical illumination with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 113 | S & F Recess mountedLEDLight, circular type suitable for fixing in 2\" X 2\" Grid False Ceiling of not less than 1800 Lumens output, 5700 K with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 114 | S & F Recess mountedLEDLight, circular type suitable for fixing in 2\" X 2\" Grid False Ceiling of not less than 900 Lumens output, 5700 K with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 115 | S & F LED type decorative engagement light with and including green & red colour LED bulb with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm including taking down existing light fittings of any description and making good the disturbed surfaces to match with existing complete all as specified and as directed.Note: Light fitting shall be of PF>0.95 |
| 116 | S & FEnergy efficient Sleek LED Mirror Light Fitting of not less than 1000 Lumens, 2 feet long Surface & Wallmounted with Acrylic / PMMA diffuser for soft glare free light with all accessories internally prewired and including connecting up with twin core PVC insulated, sheathed flexible copper conductor cable of size 1.5 Sq.mm and making good the disturbed surfaces to match with existing complete all as specified and as directed. Note: Light fitting shall be of PF>0.95 |
| 117 | S & F Wall Mounted decorative type Air Circulator Fan,400mm Sweep, Metal Body, Heavy duty with double ball bearing, low noise,Copper wound, 1400 RPM, Air Delivery not less than 270 Cum/min, wattage consumption not more than 190 watts, 230 Volts, AC, 50 Hz, Conforming to IS, complete with wall bracket and mounting accessories kit complete all as specified and as directed. |
| 118 | Supplying, installing, testing and commissioning of 5 Star rated Hi-Wall Split Units Indoor / Outdoor with Cordless Remote Control Unit and with in-built advanced Air Ioniser and Plasma Filters for better indoor air quality with latest Inverter technology, having Eco friendly Refrigerant Gas, Copper Condenser Coil, EER 3.2 of Capacity 2.0 TR, Summer Cool, Dual Rotor Inverter Compressor, Automatic 4D Swing Copper Condenser, BLDC Motor, necessary copper pipe connections including cutting, bending, brazing, insulation on pipe etc, PVC Drain Pipe, electric connection between indoor and outdoor unit with suitable size PVC insulated, multi-stranded copper cable complete all as specified and as directed.Make: Blue Star / Hitachi / Daikin / Carrier Notes: [a] The rate quoted by the contractor is deemed to include for Powder Coated Mild Steel Fixing Brackets for Outdoor and Indoor Units at any height and Copper tube of suitable size and length and Drain Pipe made of High Density Polyethylene Pipes [HDPE] of pressure rating 6 KGf / Sq.cm of 25mm dia upto 5m length.[b] The copper tube of suitable size beyond 5metres from each AC unit shall bemeasured and paid separately under respecitive items of this schedule. |
| 119 | S & F Electronic wall mounted time delay Voltage stabilizer, automatic operation, single phase, naturally air cooled, indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 with accuracy ± 2.5% and speed of correction 25 Volts per second complete all as specified and as directed .Make: V Guard / Servo / Kee Line |
| 120 | Taking down indoor and outdoor units of Split Air Conditioner of any capacityand of any description carefully from its position including cleaning, carrying out minor repairs, providing new insulating to the copper pipe lines and replacement of Nuts & Bolts etc. and re-fixing the same after repairs to buildings, at same location or at new location as directed including connecting up and testing complete all as specified and directed. |
| 121 | M & L for restoring the refrigerent gas in existing widow type/ Split type ACs of capactiy 2.0/ 1.5 Ton capacity after disconnecting the supply mains and refixing the same including connecting up all supply mains and sealing the copper pipe lines complete all as specified and as directed.Note:- The contractor shall keep the AC units in his safe custody during the execution of work and any damage occured to existing AC units shall be made good by the contractor without any extra cost to the department. |
| 122 | Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed. |
| 123 | Supply, Installation and Testing of Maintenance Free sealed Tripod Chemical Earthing Systemby drilling of 300mm dia hole upto a depth not less than 3.5m below normal ground level and providing 3 Nos. of copper electrod rods of size 17.2-20mm dia x 3.0m length arranged in triangular shape duly bonded with 250 micron copper molecularbonded clamps, buried directly and vertically in the hole connected with copper earth strip 20 x 3mm size up to 7.5m length by means of bolts, nuts, check nuts and washers of copper connected to earthing test point including providing of earth enchancing mineral compound consisting of 2 Bags [11.3 Kg Each] of Ground Enhancement Material conforming to IEC 62561-7 with a resistivity of less than 0.04 ohm-m with each Earth Rod to reduce the soil resistivity tested for leaching and TCLP with NABL accredited Lab as per IEC 62561-7, including testing on completion complete all as specified and as directed. |
| 124 | Notes:[a] Earth Pit shall be constructed by drilling hole of 300mm dia up to 3.50m deep using earth auger or any other method. The soil shall be sieved to remove the gravels and stones. If the soil seems unusable i.e. containing large quantity of Gravel, Stones, Moorum, Sand etc., the same shall be replaced with black cotton soil. The approved screened soil shall be modified with 2 Bags of [11.3 Kg Each] Ground Enhancement Material conforming to IEC 62561-7 and shall be used as backfill. The electrode shall be inserted at the centre of the earth pit and kept vertical in the pit. The pit shall be filled with the earth enhancement material duly surrounding the electrodes and simultaneously the pit shall be adequately watered i.e. approximately 600 litres for each pit. The backfill shall be compacted with a steel bar or pipe by stirring intermittently for removing the air pockets and proper settlement of the pit. [b] The unit rate quoted shall be deemed to include for PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways or Cast Iron Cover, MS frame made with 40 X 40 X 6 mm Angle Iron, MS handle 12mm dia, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed. |
| 125 | S & FEarth continuity Conductor or main earthing lead made of Copper Strip of size 20 X 3mm, fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed. |
| 126 | S & FTest Point Terminal Box of size 200 X 100 X 100mm made out of 2mm thick hot dip galvanised sheet, drilled and screwed including 6 Nos 15mm long hexagonal head screws complete with Test Point Terminal Block made of Gun Metal or Phosphorus Bronze of size 75 X 75 X 25 mm drilled and screwed including 3 Nos 8 mm dia 25 mm long hexagonal head screw complete all as specified and as directed. |
| 127 | M & L for Cutting Bituminous Road / Hardstanding, etc. as required for Jointing / Laying Cables and Pipeline of width not exceeding 300mm and depth not exceeding 600mm and refilling after laying and making good with PCC 1:2:4, Type B1 using 20mm graded stone aggregate, 100mm thick complete all as specified and as directed. |
| 128 | Supplying and laying GI pipe, 40mm dia, Light grade for Earth continuity conductor or main earthing lead protection laid in trenches or fixing on wall / poles of any type, secured with clamps complete all as specified and as directed. |
| 129 | Supplying, installing, testing & commissioning of Single phase, 2 wire, Smart Prepaid Energy Meter of rating 5-60A, 240 volt, 50 Hz accuracy class 1.0 conforming to IS - 16444: 2015 (Reaffirmed 2020), with in built electronic touch/ push button type keypad, separate display unit/ Consumer interface Unit IEC 62056 & IS 15959 Protocal Part-2,optical port for Local Communication and BLE for Remote access along with 10 Years warranty, Demo and training after supply of Prepaid meters complete all as specified and as directed with following specification.:- (a) Voltage rating :- 240 V (+20% , -40%)(L-N)(b) Current rating:-5 Amp-max 60 Amp(c) Class of Accuracy:- Class 1.0(d) Rated Frequency:- 50Hz+/-5%(e) Maximum continuos current:- 60 Amps(f) Current circuit capacity at rated current :- < 2.5 VA per phase(g) Voltage circuit capacity at rated voltage :- < 2 W/10 VA per phase(h) Output display :- LCD type(i) Load Limitation :- Feature shall be available for the maximum demand in KW , shall be configured(j) Prepayment :- Meter shall be having facility with the pre-payment features.(k)Tariff:- The system shall provide encrypted code generated for each transaction with the meter and changing of Tariffs in the meter. The transaction shall include Transfer of Credit to meter.(xii) Automatic Power supply disconnection for non payment customer.Make:- SECURE , HPL , L & T or any BIS Approved Make conforming to IS:16444Note: Energy Meter shall be provided with 10 Years onsite replacement warranty. Rate quoted is deemed to be including the same and nothing shall be paid extra on this account. |
| 130 | S & F Single Phase Hot pressed SMC Meter box of size 250 x 250 x 155 mm with viewing glass , concealed hinge and earth bolt plugged complete all as specified and as directed. Make:-Sintex/ Hensel/ HPL or equivalent approved make |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy