| 1 | Work |
| 2 | Clearing jungle I/c uprooting rand, grass, wood trees etc. I/c removal of rubbish up to a distance of 50m as per SI No 259 |
| 3 | Excavation in fdn. in ordinary soil I/c lift up to 1.5m &lead up to 30m I/cdisposal of surplus earth etc. complete as per SI No.251 (a). |
| 4 | Concrete with 40mm gauge brick ballast, fine sand of 1.25 FM & cement in proportion of 1:4:8 etc. I/c all complete as per SI No 281. |
| 5 | M150 class B/W in 1:6 with cement and coarse sand 2.25 Fm. mortar inplinth & foundation SI. 305(a) |
| 6 | R.C.C. work with cement, coarse sand & 2cm gauge stone ballast in 1:1.5:3 in column footingetc. complete as per SI. No.287A. |
| 7 | R.C.C. work with cement, coarse sand & 2cm gauge stone ballast in 1:1.5:3 in columnetc. complete as per SI. No.288A. |
| 8 | R.C.C. work with cement, coarse sand & 2cm gauge stone ballast in 1:2:4in plinthbend, etc. complete as per SI. No.283. |
| 9 | Earth filling in plinth I/c supply of necessary quality of earth by cartage 3 km. etc. I/c all complete. |
| 10 | Sand filling in plinth I/c supply of necessary quality of sand etc. I/c all complete as per SI No 255 |
| 11 | M-150 Class B/worksin 1:6 Cement & C/Sand mortar in S/structure i/c supply of all materials labour, T and P etc complete as per SI No.303+309+310+ Difference cost of fine sand to coarse sand |
| 12 | M-150 brick work in 1:4 cement & coarse sand mortar in s/str in half brick wall etc. complete SI No. 305+309+310(a). |
| 13 | R.C.C. work in 1:1.5:3 with Cement,coarse sand and 2cm guage stone grit for beami/c all etc. CH. 15 SI NO. 285a |
| 14 | R.C.C. work in 1:1.5:3 with Cement,coarse sand and 2cm guage stone grit for slab i/c all etc. CH. 15 SI NO. 288(a) |
| 15 | 12 mm thick plaster with cement and coarse sand mortar in 1:6 on smooth surface of wall/c all complete as per SI No.586. |
| 16 | 12 mm thick plaster with cement and coarse sand mortar in 1:6 on rough surface of wall I/c all complete. SI No.586+596. |
| 17 | Marking drip coarse in sun shades or facie with 1:3 cement and fine sand mortar i/c all complete as per Ch. 13Si 600 |
| 18 | Mild steel /iron work such as R.C.C. work i/c all etc.CH. 10 SI NO. 504 |
| 19 | Mild steel or iron work in heavy sizes such as trusses, built-up gates, door frame etc. I/c all complete as per SI No. 503. |
| 20 | Providing and fixing 1mm thich M.S. Sheet door with frame of 40x40x5mm (1½\"x1½\"x¼\") angle iron 3.15 mm (1/8\") thick M.S.in all respect as per Si No 517a |
| 21 | Providing and fixing Door and Windows in positionDoor |
| 22 | Window |
| 23 | Ventilators |
| 24 | 2.5 cm thick P.C.C. floor with cement, c. sand and stone grit in 1:2:4 without base concrete I/c all . SI No.601(a) |
| 25 | 4 cm thick P.C.C. floor with cement, c. sand and stone grit in 1:2:4 without base concrete I/c all . SI No.605 |
| 26 | Providing and fixing glass strips of 4mm thick & 35mm deep joints of floor and skirting at the time of laying labour,tools and plants etc.completeCH. 14 SI NO. 631(b) |
| 27 | Supply and fixing 6 to 8 mm thick ivory or light shede vetrified tiles in flooring and skirting i/c all cpmplete as per S I No New item 4 Ch 14 |
| 28 | Providing White cement on new surface with approvel quality material of berjer/j.k./birla etc make 2 coatsCH. 15new item |
| 29 | Finishing wall with water proof cement paint of approved make and quality on new work with two coats over one priming coat i/c all materials,labour,Tools & plant etc. complete CH. 15 SI NO. 660 & 661 + new item 2 |
| 30 | One priming coat and two coats oil bound distemper on new work I/c all complete as per SI. No.649+650. |
| 31 | Painting two coats on new iron or wood work with approved ready mix paint over and I/c. priming coat I/c. all complete as per SI. No. 641+642 |
| 32 | 20mm thick plastering with 1:2 cement and course sand mortar in dedo or in skirting i/c all complete. SI No 597 |
| 33 | S/f offan box comp all. As per S.I. No 1149 |
| 34 | Wiring point for light with 1.5 Sq.mm FR PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit.as SI-131-(C)and add SI No 187(A) for Modular Switch |
| 35 | Wiring point for fan with 1.5 Sq.mm FR PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. As SI-133-cand add SI No 187(A) for Modular Switch |
| 36 | Wiring point for plug with 1.5Sq.mm FR PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. As SI-134-C add SI No 187(C) for Modular Switch |
| 37 | Supply and Fixing of Power plug with 2Amp /250 Volt Flush type Modular swith all as per SI No 1139(A) |
| 38 | Supply and fixing of ElectronicFan regulator (Modular) 120 to 280 Volt ISI marked all as per SI No 1203(A) |
| 39 | S/F of 40 Amp DP MCB (10KA C curveas per SI 1010 CAT A |
| 40 | S/Wof Sub main with 2 nos 2.5 sq.mm. FR PVC insulated M/S Multi core Copper Conductor cable As per SI No. 1307(C) |
| 41 | Supply and Fixing of ceiling fan of approved make i/c all complete |
| 42 | S/f of sign board i.e all complete |