Tender For Improvement Of Lighting Arrangement Of Various Bps In Ac-44., Delhi-Delhi

Delhi Jal Board-DJB has published Tender For Improvement Of Lighting Arrangement Of Various Bps In Ac-44.. Submission Date for this Tender is 13-03-2023. Bolts Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

36640847
Tender For Improvement Of Lighting Arrangement Of Various Bps In Ac-44.
Open Tender
Indian
Delhi
Delhi
13-03-2023

Tender Details

Improvement Of Lighting Arrangement Of Various Bps In Ac-44. , Internal & External Electrification At 1. Sec-01 Bps R.K Puram.. 2. Hill View Bps. 3. Vasant Apartment Bps. By Caring Out Following Works: - Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthling The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. ( 15 Point In Each Bps ) , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 3 Pin 5 / 6 Amps Modular Socket Outlet And 5 / 6 Amps Modular Switch, Connection Etc. As Required. ( For Light Plugs To Be Used In Non-Residential Buildings ) . , Wiring For Light / Power Plug With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit Along With 1 No 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. ( Approx. 30Mtrs In Each Bps. , Supplying And Fixing Suitable Size Gi Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providing And Fixing 6 Pin 5 / 6 & 15 / 16 Amps Modular Socket Outlet And 15 / 16 Amps Modular Switch, Connection Etc. As Required. ( 01 Nos. In Each Bps ) , Installation, Testing And Commissioning Of Ceiling Fan, Including Wiring The Down Rods Of Standard Length ( Up To 30 Cm ) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. ( One No. In Each Bps ) , Installation, Testing And Commissioning Of Pre-Wired, Fluorescent Fitting / Compact Fluorescent Fitting Of All Types, Complete With All Accessories And Tube Etc. Directly On Ceiling / Wall, Including Connection With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable And Earthing Etc. As Required. ( 5 Nos. In Each Bps ) , Wiring For Circuit / Sub Main Wiring Along With Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 1.14.12 X 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire ( 30 Mtrs In Each Bps ) , Supplying And Fixing Following Way Prewired Sp&N Mcb Distribution Board Of Steel Sheet For 240 Volts On Surface / Recess Complete With Loose Wire Box, Terminal Connectors For All Incoming And Outgoing Circuits, Duly Prewired With Suitable Size Frls Pvc Insulated Copper Conductor Up To Terminal Blocks, Tinned Copper Bus Bar, Neutral Link, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 2 + 4 Way / 6 Way , Double Door ( One No. In Each Bps ) , Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required Single Pole. ( 3 No. In Each Bps ) , Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps ( One No. In Each Bps ) , S / O Ceiling Fan, 1200 Mm Sweep Make: -Havells / Crompton / Any Djb Approved Make ( One No. In Each Bps ) , S / O Wall Fan, 400 Mm Sweep Make: -Havells / Crompton / Any Djb Approved Make ( One No. In Each Bps ) , S / O 20 Watt Led Tube Light Complete Fitting With Tube Make: - Havells / Crompton / Bajaj / Philips / Any Djb Approved Make. ( 5 Nos. In Each Bps ) , S / O Energy Saving Environmental Friendly, Long Life, Exclusive Innovative Pressure Die Cast Aluminium Bay Light With High Power Led As Light Source 70 Watt Ledlight Fitting Etc. Complete As Required For Fixing On The Wall. Make: Bajaj / Havells / Philips / Any Djb Approved Make ( 4 No. In Each Bps ) , S / O 40 Mm Dia G.I. Pipe Of 1 Meter Length With 1500 Angle Band, Suitable For Fixing Of 80 Watt Led Street Light Along With Clamp, Nut & Bolt Etc. ( 4 No. In Each Bps ) , S / O Heavy Duty Exhaust Fans, 450 Mm Sweep Make: -Havells / Crompton / Any Djb Approved Make ( One No. In Each Bps ) , Installation Testing & Commissioning Of 70 Watt Street Light Along With Grouting Of Bolt And Fixing Of Fan, Exhaust Fan And All Supply Item Etc.At Bps ( 4 Job In Each Bps )

Key Value

Document Fees
INR 500 /-
EMD
INR 5400.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Improvement of lighting arrangement of various BPS in AC-44.
Sl. No. Item Description
1Internal & External Electrification at 1. Sec-01 BPS R.K Puram.. 2. Hill View BPS. 3. Vasant Apartment BPS. by caring out following works: - Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthling the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. (15 Point in each BPS)
2Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non-residential buildings).
3Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (approx. 30Mtrs in each BPS.
4Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. (01 Nos. in each BPS)
5Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. (One No. in each BPS)
6Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper Conductor, single core cable and earthing etc. as required. ( 5 Nos. in each BPS)
7Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 1.14.12 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (30 Mtrs in each BPS)
8Supplying and fixing following way prewired SP&N MCB distribution board of steel sheet for 240 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)2 + 4 way/ 6 way , Double door (One No. in each BPS)
9Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole. (3 No. in each BPS)
10Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps (One No. in each BPS)
11S/O ceiling fan, 1200 mm sweep Make: -Havells/ Crompton / any DJB approved make(One No. in each BPS)
12S/O wall Fan, 400 mm sweep Make: -Havells/ Crompton/ any DJB approved make (One No. in each BPS)
13S/O 20 watt LED Tube light complete fitting with tube Make: - Havells / Crompton / Bajaj / Philips/ any DJB approved make. (5 Nos. in each BPS)
14S/O Energy saving environmental friendly, long life, exclusive innovative pressure die cast aluminium bay light with high power LED as light source 70 watt LEDlight fitting etc. complete as required for fixing on the wall. Make: Bajaj / Havells / Philips/ any DJB approved make (4 No. in each BPS)
15S/O 40 mm dia G.I. pipe of 1 meter length with 1500 angle band, suitable for fixing of 80 watt LED street light along with clamp, Nut & Bolt etc. (4 No. in each BPS)
16S/O Heavy Duty Exhaust Fans, 450 mm sweep Make: -Havells/ Crompton/ any DJB approved make (One No. in each BPS)
17Installation Testing & Commissioning of 70 watt street light along with grouting of bolt and Fixing of fan, exhaust fan and all supply item etc.at BPS (4 Job in each BPS)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail