Tender For Repair/Replacement Of Oh Conductor To Ug Cables For Standby Dg Set Supply At Certain Locations (Phase-I) At Af Station Gwalior, gwalior-Madhya Pradesh

Military Engineer Services-MES has published Tender For Repair/Replacement Of Oh Conductor To Ug Cables For Standby Dg Set Supply At Certain Locations (Phase-I) At Af Station Gwalior. Submission Date for this Tender is 23-03-2023. Conductor Tenders in gwalior Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

36579555
Corrigendum : Tender For Repair/Replacement Of Oh Conductor To Ug Cables For Standby Dg Set Supply At Certain Locations (Phase-I) At Af Station Gwalior
Open Tender
Indian
Madhya Pradesh
gwalior
23-03-2023

Tender Details

Repair / Replacement Of Oh Conductor To Ug Cables For Standby Dg Set Supply At Certain Locations ( Phase-I ) At Af Station Gwalior

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 15-Mar-2023 DATE AMENDMENT Date 23-03-2023
2 15-Mar-2023 BOQ AMENDMENT BOQ 23-03-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 41600.0 /-
Tender Value
INR 20.80 Lakhs /-

BOQ Items

Name of Work:REPAIR/REPLACEMENT OF OH CONDUCTOR TO UG CABLES FOR STANDBY DG SET SUPPLY AT CERTAIN LOCATIONS (PHASE-I) AT AF STATION GWALIOR
Sl. No. Item Description
1Disconnecting, dismantling and taking out old ACSR conductor out lived/broken including removing binding wire from insulators/jumpers ( including removing cross arms bracing and insulators) all as specified and directed.
2Supplying and layingand testing XLPE insulated, armoured, heavy duty electric cable with aluminum conductor 1100 volts grade, cross-sectional area 35 sqmm 3.5 core laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge Make of Cable: Grandlay/Havells/Polycab
3Supplying and layingand testing XLPE insulated, armoured, heavy duty electric cable with aluminum conductor 1100 volts grade, cross-sectional area 25 sqmm 4 core laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge Make of Cable: Grandlay/Havells/Polycab
4Supplying and layingand testing XLPE insulated, armoured, heavy duty electric cable with aluminum conductor 1100 volts grade, cross-sectional area 16 sqmm 4 core laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge Make of Cable: Grandlay/Havells/Polycab
5Supplying and layingand testing XLPE insulated, armoured, heavy duty electric cable with aluminum conductor 1100 volts grade, cross-sectional area 10 sqmm 2 core laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge Make of Cable: Grandlay/Havells/Polycab
6Supplying and fixing PVC (Sinthetic) boxes of size 280mm x 170mm x 115mm depth. The box shall be provided with and including 10 cm long aluminium bus bar of size 20x3 mm size 2 Nos mounted on porcelain insulators including one No. MCB SP of `C series, 5/6 Amps of Make Legrand/L&T/ Siemens and connecting the bus bars to cables with using suitable GI nut, bolts and washers and aluminum lugs etc fixed on pole using 30x5 mm Gl clamps, nuts, bolts & washers etc complete all as specified and directed by Engineer-in-Charge. Note :- The contractors quoted rates for the above items are deemed to include for fixing the Sinthetic box in position with suitable MS clamps and/or necessary PCC as per site requirement.
7Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed.
8Returning, filling in, including spreading leveling, watering and well ramming the excavated soil in layers not exceeding 25 cm thick complete all as specified and directed
9Removal of surplus excavated soil to a distance not exceeding 50 Mtr distance and depositing as directedat a level not exceeding 1.5 mtr above starting point complete all as specified and directed
10M & L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge.NOTE:- For measurement purpose punned thickness shall beconsidered as per clause 19.75 of SSR Part-I
11Supplying & Laying Sub Class `B’ bricks, old size, kiln burnt,laid with axis of brick perpendicular to the axis of the cable, for protection of cable all as specified and directed by Engr-in-Charge.
12Supplying, laying & jointing 40 mm bore GI water tubing light grade as in sleeving etc laid in trenches / ducts / horizontal bore hole complete all as specified and directed by Engineer-in-Charge. MAKE:-TATA/JINDAL/SWASTIC
13M&L for PCC (1:3:6 ) type C-2 ( using 40 mm graded stone aggregates ) as in sub base foundation etc. complete all as specified and directed
14M&L for PCC (1:2:4 type B-1 with20 mm graded stone aggregates for coping poles with all necessary form work complete all as specified and directed
15Demolition for cement concrete/road in ground floor and paving n. exc 15 cm thickness below or above ground level including removal of rubbish to a distance 25 m and n.exc 50 m etc complete all as specified
16Supply, install, testing & commissioning of distribution LT panel OUTDOOR cubicle type made out of 3.15 mm thick CRCA sheet powder coated internally and externally, with both side opening and panel key type locking arrangement including two set of locks with three Nos of keys with seperate compartment for every switch gear. Should be IS/EC:61439-1:2011 IS/IEC:61439-2:2011 type test certificate for short circuit test and degree of protection IP-56 ,duly grouted on floor over cable duct and having sufficient working space completecomprising of the followingaccessories all as specified and directed (a) Bus bar Aluminium suitable Amp with colour code suitable for 4 wire system (Red, Yellow, Blue and Black) |(b) Voltmeter 0-500 with three phase selector switch -01 Nos |(c) Ammeter suitable Amps with CT"s of suitable size and three phase selector switch-01 Nos (d) Phase indicating lamps -03 Nos In coming- 1. MCCB - 63 Amps, 415V, 4 Pole, AC with thermal setting 70% to 100% and 36 KA-01 No. Out going 1. MCCB - 40 Amps, 3 Pole, AC with thermal setting 70% to 100% and 25 KA-02 Nos. 2. Spare place for fixing any switch gear in future-01 No 3. Including supply and fix inside of panel time swiches astro type (Having logitude and latitude of Indian cities in memory) 415V three phase of 20 Amp rating with cotactor fitted inside steel enclosure. Make of panel : Indo Asian/Shalabh (Ilndia) Roorkee/Power System & Control Jalandhar/Rew Constructions Pvt Ltd Make of MCCB : L&T, ABB, Siemens, Schneider.
17Supply, install, testing & commissioning of distribution LT panel OUTDOOR cubicle type made out of 3.15 mm thick CRCA sheet powder coated internally and externally, with both side opening and panel key type locking arrangement including two set of locks with three Nos of keys with seperate compartment for every switch gear. Should be IS/EC:61439-1:2011 IS/IEC:61439-2:2011 type test certificate for short circuit test and degree of protection IP-56 ,duly grouted on floor over cable duct and having sufficient working space completecomprising of the followingaccessories all as specified and directed (a) Bus bar Aluminium suitable Amp with colour code suitable for 4 wire system (Red, Yellow, Blue and Black) |(b) Voltmeter 0-500 with three phase selector switch -01 Nos |(c) Ammeter suitable Amps with CT"s of suitable size and three phase selector switch-01 Nos (d) Phase indicating lamps -03 Nos In coming- 1. MCCB - 40 Amps, 415V, 4 Pole, AC with thermal setting 70% to 100% and25 KA-01 No. Out going 1. MCCB -32 Amps, 3 Pole, AC with thermal setting 70% to 100% and 16 KA-02 Nos. 2. Spare place for fixing any switch gear in future-01 No 3. Including supply and fix inside of panel time swiches astro type (Having logitude and latitude of Indian cities in memory) 415V three phase of 20 Amp rating with cotactor fitted inside steel enclosure. Make of panel : Indo Asian/Shalabh (Ilndia) Roorkee/Power System & Control Jalandhar/Rew Constructions Pvt Ltd Make of MCCB : L&T, ABB, Siemens, Schneider.
18Material and labour for earthing complete with galvanized steel earth plate electrode600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1. 5m below ground level) connected to galvanized iron earth strip 25 X4 mm (main earthing lead) by means of galvanised bolts, nuts and washers as Shown in electrical plate No 3 of MES Schedule Part-I [(2009) connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia Gl pipe medium grade for earth lead protection pipe for suitable length land GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1:3:6) type C-1 for earth pit, interenal surface of concrete shall be given 10mm thick plaster in CM 1:4 and 40mm thick precastRCC cover1:2:4 (using 12mm of aggregate) reinforced with 8mm dia TMT bars # 75mm c/c both ways with 12mm dia round bar as in handle complete all as spcecified and directed by Engineer-in-Charge. Note:(i)Test result of earthing to be submitted by the contractor for all earthing . (ii) Earth flling shall be done by vegetable soil. (iii) Soil should be free from stone, boulders aggragates, gravel etc. (iv) The rate quoted by the bidders shall be also be deemed to include -(a) Supply of charcoal and common
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy