Tender For Replacement Of Ac Sheet Roof By Galvalume Sheet And Connected Items To Certain Otm Accn Lbw 08 And Provn Of Hardstanding Veh Parking Shed For Veh Near Bldg No P 341 Of Scc Bhopal Mw 23 At Si Lines Under Ge Bhopal, bhopal-Madhya Pradesh

Military Engineer Services-MES has published Tender For Replacement Of Ac Sheet Roof By Galvalume Sheet And Connected Items To Certain Otm Accn Lbw 08 And Provn Of Hardstanding Veh Parking Shed For Veh Near Bldg No P 341 Of Scc Bhopal Mw 23 At Si Lines Under Ge Bhopal. Submission Date for this Tender is 25-03-2023. Shed Construction Tenders in bhopal Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

36501171
Corrigendum : Tender For Replacement Of Ac Sheet Roof By Galvalume Sheet And Connected Items To Certain Otm Accn Lbw 08 And Provn Of Hardstanding Veh Parking Shed For Veh Near Bldg No P 341 Of Scc Bhopal Mw 23 At Si Lines Under Ge Bhopal
Open Tender
Indian
Madhya Pradesh
bhopal
25-03-2023

Tender Details

Replacement Of Ac Sheet Roof By Galvalume Sheet And Connected Items To Certain Otm Accn Lbw 08 And Provn Of Hardstanding Veh Parking Shed For Veh Near Bldg No P 341 Of Scc Bhopal Mw 23 At Si Lines Under Ge Bhopal

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 18-Mar-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 25-03-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 98000.0 /-
Tender Value
INR 48 Lakhs /-

BOQ Items

Name of Work : REPLACEMENT OF AC SHEET ROOF BY GALVALUME SHEET AND CONNECTED ITEMS TO CERTAIN OTM ACCN (LBW-08) AND PROVN OF HARDSTANDING, VEH PARKING SHED FOR VEH NEAR BLDG NO. P-341 OF SCC BHOPAL (MW-23) AT SI LINES UNDER GE BHOPAL
Sl. No. Item Description
1Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
2M&L forcutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10cm girth complete all as specified and directed.
3M&L for cement concrete type B1, 1:2:4 (using 20mm graded stone aggregate) as in roof kerbs or mud stops, copings an levelling concrete etc slightly rounded or chamfered angles and throating complete all as specified and directed.
4M&L for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation, sub base etc complete all as specified and directed.
5M&L for preparation of old wooden surface of any decription and applyingtwo coats of synthetic enamel paint complete all as specified and directed.
6M&L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick wall finished even and smooth without using extra cement mixed with water proofing compound complete all as specified and directed. Note:- water proofing compound shall be measured and paid seperately.
7M&L for 15mm thick rendering in CM 1:6 on fair face of brick walls/ concrete surfaces finished even and smooth without using extra cementcomplete all as specified and directed.
8Supply only integral water profing compound complete all as specified and directed.
9Taking down cement plaster, terrazzo/cement dado, skirting etc of any description on brick/stone walls,concrete surfaces etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
10M&L for preparation of newly plastered surface and applying two coats of oil emulsion distemper tinted over one coat ofwhite cement based putty complete all as specified and directed. Note :- Putty shall be measured and paid separately.
11Preparing new plastered or un-plastered surfaces of wall and M&L for applying two coats of exterior acrylic emulsion weather coat paint, white or tinted complete all as specified and directed.[Make:- Apex Paint of M/s Asian Paints or equivalent in M/s Berger or M/s ICI as approved by GE] NOTE:- (a) 3mm thick wall care cement putty where ever required shall be measured & paid separately. (b) The work of applying exterior acrylic emulsion paint shall be carried out by authorized representative/applicator of the manufacturer. (c) A Guarantee of 5 yrs from the certified date of completion for the effectiveness of exterior acrylic emulsion weather coat paint shall be submitted by the manufacturer and contractor. (d) A Security deposit @2.5% of the amount of treatment shall be deposited by the contractor for the entire guarantee period i.e. 5 yrs in the form of FDR in favour of GE. (e) During the guarantee period if exterior acrylic emulsion weather coat paint gets removed or becomes layered contractor shall rectify or replace (at his option) defective materials at his own expenses, when called upon in writing to do so by the GE.Condition 46 of IAFW-2249 (defects liability period) for the guarantee period shall be deemed amended accordingly for the work.
12Complete removal of existing treatment on walls (any number of layers) by scrapping including filling holes, cracks, depressions of scrapped surfaces with putty and preparation of surfaces for further treatment andM&L for applying two coats of exterior water base emulsionpaint, white or tinted complete all as specified and directed.[Make:- Apex Paint of M/s Asian Paints or equivalent in M/s Berger or M/s ICI as approved by GE] NOTE:- .(a) The work of applying exterior emulsion paint shall be carried out by authorized representative/applicator of the manufacturer. (b) A Guarantee of 5 yrs from the certified date of completion for the effectiveness of exterior acrylic emulsion weather coat paint shall be submitted by the manufacturer and contractor. (c) A Security deposit @2.5% of the amount of treatment shall be deposited by the contractor for the entire guarantee period i.e. 5 yrs in the form of FDR in favour of GE. (d) During the guarantee period if exterior acrylic emulsion weather coat paint gets removed or becomes layered contractor shall rectify or replace (at his option) defective materials at his own expenses, when called upon in writing to do so by the GE.Condition 46 of IAFW-2249 (defects liability period) for the guarantee period shall be deemed amended accordingly for the work.
13M&L for complete removal existing treatment, preparation of plastered or unplastered old surfaces, washing, rubbing down and stopping of distempered and painted surfaces and applying two coats of oil emulsion distemper tinted over one coat ofwhite cement based putty complete all as specified and directed. Note : Putty shall be measured and paid separately.
14M&L for 3mm thick wall care putty on wall/ceiling complete all as specified and directed.
15M&L for Cement concrete 1:3:6 type C2 using 40mm graded stone aggregate in plinth protection, 75mm thick, finished even and smooth without using extra cement, including making joints 12mm wide to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:3 by weight complete all as specified and directed.
16Demolition of concrete in ground floors and pavings (un reinforced) nexc 15 cm thickness (below or above ground level) complete all as specified and directed.
17Demolition of brick work or stone masonery built in cement mortar complete all as specified and directed.
18M&L for brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick wallsbuilt in CM 1:4 using modular bricks complete all as specified and directed.
19M&L for brick work with fly ash bricks in CM 1:4 using modular bricks straight or curved on plan to any radius complete all as specified and directed.
20Dismantling of Asbestos cement (corrugated ted, semi corrugated, etc.) sheets in roof coverings complete all as specified and directed.
21Dismantling timber fillets, rails, posts, rafters, purlins, etc. under 40 Sq cm in section in framed work complete all as specified and directed.
22Dismantling timber scantling 40 sq cm and over in section, in any position in unframed work complete all as specified and directed.
23S&F mild steel rolled section/tubular sections in purling, cross, beam, rafter,posts etc. incl connected cleats, hold fasts etc of grade conforming to Fe 410-W (Gde E-250) quality-B complete all as specified and directed.
24S&F mild steel wind ties for roof truss including necessary drilling bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
25M&L for pre-painted galvalume aluminium zinc coating GI based corrrugated steel sheet 0.50 mm thick, 150 Az, of any color having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self-tapping screws on angle iron frame of each side complete all as specified and directed.
26M&L for Pre-painted Galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick, 150 Az of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw/L type or J type cranked hook boltscomplete all as specified and directed.
27M&L for preparation of old painted surfaces of steel and iron surface of any description and applying two coats of synthetic enamel paint complete as specified and directed.
28M&L for preparation of new steel surface of any description and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
29S&F Mild steel work conforming to Fe-290 Gde E-165 in framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars; ladders; railings and similar work complete all as specified and directed.
30Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed.
31Cutting holes in brick walls exc half brick but not exc one brick in cement mortar or cement lime mortor for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed.
32S&F galvanised cold rolled steel section framed work size 600x600mm grid size 24x38x0.60mm Tee (bottom precoated) and 24x24x0.50mm thick wall angle galvanised cold rolled steel section incl expansions fasteners as in ceiling as approved by GE complete all as specified and directed.
33S&F 6mm thick Asbestos free calcium silicate board of size 600x600mm fixed to frame of galvanised cold rolled steel frame work as in ceiling including applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
34M&L for ShaliCryl ® 215single component, UV resistant, unique elastomeric, high build exterior waterproofing coating based on a revolutionary acrylic polymer with quick-set capabilities to resist moisture attack in following sequence:- (a) Surface Preparation :- Remove all loose and foreign materials, if any, by a wash with a jet of air / water. • Repair structural defects before application of ShaliCryl® 215. • Fill voids and undulation area with Polymer Mortar made out of ShaliSBR Latex, Water, Cement and Sand in the Ratio of 1:1:5:12.5. • Fill cracks up to 3 mm with PlastiSeal and cracks over 3 mm with PlastiSeal P after opening the crack to a “V” cut. • In case of any poor plaster surface in existence (for old building), remove the same and corrected with new cement : sand in the ratio of 1 : 4 admixed with ShaliPlast LW+ @ 200 ml / bag of cement. (b)Primer Application :-Apply ShaliPrime WB as Primer after dilution with potable water in the ratio 1:0.5 for a theoretical Coverage 8-10 m2 / L of the mix and allow it to dry for 3 – 4 hrs. post elimination of undulation, roughness of concrete, joint marks, Voids and any other surface correction. (c)Application of Material • Apply first coat of ShaliCryl® 215 over the primed surface @ 160 ml / m2 . Add maximum of 10% potable water by volume for the first coat only, if required, to have brushable consistency only. • Allow the applied coating to dry 6 – 8 hrs of application. • Apply second coat of ShaliCryl® 215 without dilution over dried first coat @ 140 ml / m2 and allow it to dry. • Do not undertake any further work over the coated area within 72 hrs of final coat. • A coat of 100 micron of ShaliCryl TC 100 will improve water / dust repellent property.
35S&F in repairs decorative stainless steel 25mm dia, minimum thickness 1mm curtain rod with powder coated side fixing brackets, rings and decorative knobs complete all as specified and directed.
36Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed.
37Surface dressing in hard/dense soil n.exc 15 cm deep complete all as specified and directed.
38M&L for broken stone Hardcore of guage n.exc 63mm, deposited, spread and leveled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
39M&L for moorum filling in floors or paving, laid in layers n.exc 15cm thick, spread, levelled and rammed including watering complete all as specified and directed.
40Excavation in Post holes (or similar holes) each not exc 0.5 cum, getting out complete in hard rock complete all as specified and directed.
41M&L for cement concrete Type B2 1:3:6 (using 40 mm graded stone aggregate) in foundations, post holes filling and mass concrete complete all as specified and directed.
42S&F 3mm thick plain mild steel plateswelded to frame or truss conforming to Gde-E-250 quality-A complete all as specified and directed.
43M&L for Factory made, machine pressed, M-35 grade concrete interlocking paver blocks (glossy /reflective type), with grey cement and pigment, any shape and size conforming to IS:15658-2006 (ISI Marked) of 60 mm thickness with & including 50 mm thick sand cushion and joints filled with sand complete all as specified and directed.
44Excavation in trenches n exc 1.5 m wide and n exc 1.5 m in depth for foundation, etc. or for shafts, wells , cesspits, manholes, pier holes etc, n exc 10 sqm on plan and not 1.5 m depth and getting out in hard/dense soil complete all as specified and directed.
45Returning, filling in including spreading, levelling watering and well ramming in layers n.exc. 25 cm thick complete all as specified and directed.
46Removing excavated material exc. 250 m but n exc 500 m and depositing where directed complete all as specified and directed.
47Taking down carefully the old U/S aluminum point wiring (light, fan, socket or power) complete fitting such as switches, ceiling roses, pendants, sockets, regulators, wall light fittigs, tube light fittings, surface light fitting, ceiling light fittings, any types of fittings etcand making good disturbed surfaces of walls including necessary touch up with the same finishes to surrounding wall, floors etc complete all as specified and directed.
48M&Lforpoint wiring complete for light/ fan on independent /combine boardwith cable 1.5 sqmm (Nominal area) FRLSPVC insulated multistranded unsheathed copper conductor,drawn in concealed PVC conduit should not less than 20 mm dia and includingjuction covers and junction boxes, sunkencast iron/ pressed steelterminal boxes duly grouted in bricks cement or wooden planks wall andpainted with red oxide metal primer for mounting ofswitches, sockets, fan regulatorwith 3 mm thick plastic laminated sheet top cover fixedwith brass screwed and cup washers includingmaking good to disturbed surfaces of wallin CM 1:3 with white/colour wash as per adjoining specificationsincluding provision ofcontinuousearth continuity wireof 1.5 sqmm copper PVC insulated insulatedFRLScable for one light/ fan point controlled by one switchand connected to commonearth dolly, complete all as specified and directed.
49All as per Srl item No - 47 here in before but for one switch socket combination5/6 amp on independent board complete all as specified and directed.
50All as per Srl item No -47 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed.
51All as per Srl item No. 47 here in before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with wire of size 2.5 Sqmm and 2.5 Sqmm as earth wire complete all as specified and directed.
52All as per Srl item No. 47 here in before but for one switch socket combination 6 pin 5/ 15 Amps on independent board with wire of size 4 Sqmm and 4 Sqmm as earth wire.complete all as specified and directed.
53S&F switch piano flush type 5/6 Amps single pole one way complete all as specified and directed.
54S&F Socket outlet 5 pin 5 Amps flush type complete all as specified and directed.
55S&F switch socket combination 6 Pin, 5/16 Amps flush type complete all as specified and directed.
56S&F ceiling rose surface bakelitethree terminals complete all as specified and directed.
57S&F stepped type electronic fan regulatorcomplete all as specified and directed.
58Supply & fixing LED tube light complete fitting, surface mounted lumanaires, 1 x 18 W, 240V, Decorative ultra slim round /squar profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack with bipin holders, LED lamps, connector block, etc. complete with all accessories internally pre-wired and including connecting up with flexible copper conductor cable with suitable size complete all as specified and directed. Make : Havells Cat no LHEXBLP7N1W018 or equivalant in C&G/Bajaj/Surya)
59Supply & fixing LED tube light complete fitting, surface mounted Mirror light lumanaires, 1 x 9 W, 240V, decorative ultra slim round /squar profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack with bipin holders, LED lamps, connector block, etc. complete with all accessories internally pre-wired and including connecting up with flexible copper conductor cable with suitable size complete all as specified and directed. Make : Havells Cat No : LHEXBLP7N1W009 or equivalant in C&G/Bajaj/Surya)
60Refixing of serviceablelight fitting any type any make retrieved against item No. 46 connecting up with flexible copper conductor cable with suitable size complete all as specified and directed.
61S&F angle holder insulated body with back plate for conduit fittings complete all as specified and directed.
62S&F LEDlamp 10 Watt, B22 CDL complete all as specified and directed.
63S&F building security light fitting 35 watt, 230 v AC made up of pressure die cast aluminium housing with high effcient LED as lighting source and PC over having top opening seperate driver compartmentwith IP-66 protection and impact resistance of IK07 with suitable galvanized iron pipe “light grade” brackets1 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed. Make : Havells /Bajaj /Surya
64S&F Exhaust fan 380 mm sweep metal body with louvers 240V complete with all accessories including making hole in stone/brick wall grouting suitable size with nuts/bolts & making good in all respects complete all as specified and directed. MakeHavells Ventilair DB- NEO or equivalant in C&G/Bajaj/Usha)
65Taking down carefully existing ceiling fan any type any make,incl servicing and painting of ceiling fan with white enameled paint and refixing after celaning and painting and connection with flexible copper wire upto ceiling rose and checking of nuts bolt washers & safety pin etc completeall as specified and directed.
66S&F ceiling fan 1200 mm sweep, 240V complete with all accessoriescomplete all as specified and directed. Make Havells model - "Velocity"or equivalant in C&G/Bajaj/Usha)
67S&F in replacement of sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLS stranded copper conductor drawn in surfacePVC casing and caping size 20mm /PVC conduict dia 20mmincluding 6.00 Sq mm (Nominal Area) copper cableas earthcontinuity conductor making good the disturbed surfaces and white wash or colour wash as per adjoining specifications, necessary junction box with coversincludingconnections, PVCflexible pipesto beused while connecting the cable in DBs/Pannel, complete all as specified and directed. Note : PVC cable and PVC conduit /PVC casing and caping shall be ISI marked)
68S&F in replacement sheet metal enclosure double door typesurface mounted concealed inwallSPN 8 ways, 240 Volts, ISI marked 200 amps bus bardust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed.
69S&F in replacement MCB SP suitable for 240 volts, AC supply 6to 32 Amps ,with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
70S&F in replacement MCB SP suitable for 240 volts, AC supply 40 to 63 Amps,with over load and short circuit protection and rupturing capacity not less than 10KA, complete all as specified and directed.
71S&F in replacement MCB SPN suitable for 240 volts, AC supply6 to 32 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA,complete all as specified and directed.
72S&F in replacement MCB SPNsuitable for 240 volts, AC supply40 to 63 Amps,with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
73M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR-2009 Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by 15mm dia light grade GI pipe and watering pipe shall be 20mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed. NOTE :-(i) The concrete pit shall be PCC (1:3:6) type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii)The unit rate includes the cost of GI pipe medium grade for protection of earth wire and 4mm dia earh lead wire upto 7.5 M. (iii)PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself.
74S&F water heater storage type, elctric capacity 25 litre, BEE 5 star rated with proper electric and water connection complete all as specified and directed. Make-Bajaj/ Recold/Jaquar/Havells or equivalent as approved by GE
75Deduct Schedule of credit (calculation will be done off line) Rs. 104772.00
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy