Tender For Supply Of Various Types Of Transducers Pertaining To Grp, Switch Yard, Ht Lt System Of Stage-Iv, kadapa-Andhra Pradesh

Andhra Pradesh Power Generation Corporation Limited has published Tender For Supply Of Various Types Of Transducers Pertaining To Grp, Switch Yard, Ht Lt System Of Stage-Iv. Submission Date for this Tender is 23-03-2023. Electrical Products Tenders in kadapa Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

36466260
Corrigendum : Tender For Supply Of Various Types Of Transducers Pertaining To Grp, Switch Yard, Ht Lt System Of Stage-Iv
Tender
Indian
Andhra Pradesh
Kadapa
23-03-2023

Tender Details

Supply Of Various Types Of Transducers Pertaining To Grp, Switch Yard, Ht Lt System Of Stage-Iv , Ac Voltage Transducer ( 0-150V ) Voltage Range : 0-150V, Input Voltage :0-150V Ac, Aux Supply : 240V Ac, 50Hz, Dc Output : 4-20Ma Dc, 500 Ohm ( Max ) , Class : 0.5, Number Of Outputs : 2, Standards - Is 14570 / Iec 60688, Iec61010-1:2010, Ac Voltage Transducer ( 0-250Kv ) Voltage Range : 0-250Kv, Input Voltage : 0-125V Ac, Ptr : 220Kv / R3 / 110V / R3, Aux Supply : 240V Ac, 50Hz, Dc Output : 4-20Ma Dc, 500 Ohm ( Max ) Class: 0.5, Number Of Outputs : 2 Standards - Is 14570 / Iec 60688, Iec61010-1:2010, Ac Voltage Transducer ( 0-500Kv ) Voltage Range : 0-500Kv, Input Voltage : 0-137.5V Ac, Ptr : 400Kv / R3 / 110V / R3, Aux Supply : 240V Ac, 50Hz, Dc Output : 4-20Ma Dc, 500 Ohm ( Max ) , Class : 0.5, Number Of Outputs : 2, Standards - Is 14570 / Iec 60688, Iec61010-1:2010, Ac Current Transducer ( 0-25Ka ) Current Range : 0-25Ka , Input Current: 0-5A Ac , Ctr : 22000A / 5A , Aux Supply : 240V Ac, 50Hz, Dc Output : 4-20Ma Dc, 500 Ohm ( Max ) , Class : 0.5, Number Of Outputs : 2, Standards - Is 14570 / Iec 60688, Iec61010-1:2010, Apparent Power Transducer ( 0-720Mva ) Ctr:22000A / 5A, Ptr:21Kv / R3 / 110V / R3, Power Range: 0-720Mva, Aux. Supply:240V Ac, 50Hz, Dc Output:4-20Ma Dc, 500 Ohm ( Max ) Class : 0.5, 3 Phase 2Element ( 3Phase, 3Watt ) , Number Of Outputs : 2. Standards - Is 14570 / Iec 60688, Iec61010-1:2010, Ac Voltage Transducer ( 0-500Kv ) Voltage Range:0-500Kv, Input Voltage:0-137.5V Ac, 50Hz, Ptr:400Kv / 110V, Aux.Supply:220V Dc, Dc Output:4-20Ma, Dc, 750 Ohm ( Max ) , Class : 0.5, Number Of Outputs : 2, Standards - Is 14570 / Iec 60688, Iec61010-1:2010, Active Power Transducer ( -600 -0- +600Mw ) Ctr:1000A / 1A Ac, Ptr:400Kv / 110V, Power Range: -600 -0- +600Mw, Aux.Supply:220V Dc, Dc Output:4-20Ma Dc, 600 Ohm ( Max ) Class : 0.5, 3Phase, Number Of Outputs: 2, Standards - Is 14570 / Iec 60688, Iec61010-1:2010, Reactive Power Transducer ( -500 -0- +500Mvar ) Ctr:1000A / 1A Ac, Ptr:400Kv / 110V, Power Range: -500 -0- +500Mvar, Aux Supply: 220V Dc, Dc Output : 4-20Ma Dc, 600 Ohm ( Max ) Class : 0.5, 3Phase, Number Of Outputs : 2, Standards - Is 14570 / Iec 60688, Iec61010-1:2010, Ac Current Transducer ( 0-1200A ) Current Range: 0-1200A, Input Current:0-1A Ac, Ctr:1000A / 1A, Aux Supply: 220V Dc , Dc Output : 4-20Ma Dc, 750 Ohm ( Max ) , Class: 0.5, Number Of Outputs : 2, Standards - Is 14570 / Iec 60688, Iec61010-1:2010, Current Transducer Along With Digital Panel Meter ( Cut Out 144*144 ) , Dual Output, Ct Ratio 200 / 1 A, Range 0 - 800 A / 4-20 Ma. Standards - Is 14570 / Iec 60688, Iec61010-1:2010, Frequency Transducer, Range:45-55Hz, I / P:0-110V Ac, O / P:4-20Ma Dual, Aux. Supply:230V Ac, Accuracy:0.2%, Standards - Is 14570 / Iec 60688, Iec61010-1:2010, Programmable Multifunction Transducer For Simultaneous Measurement Of Several Variables Of An Electric Power System As Per Is 12784 And Iec 60688 .Features: 4 Programmable Universal Analogue Outputs ( 4-20Ma ) , Rated Current: 1A, Rated Voltage: 57-400V ( Ph-N ) Or 100-693V ( Ph-Ph ) , Accuracy:U / I 0.2%, Frequency 0.15%, Power 0.25%, Power Supply 85-230V Ac / Dc, Windows Software And Usb Serial Port Interface For Programming, Data Analysis Etc. ( Both Rs 232 Db-9 And Rs 485 ) , Suitable For Din Mounting. Measured Variables: Current, Voltage ( Rms ) , Active / Reactive / Apparent Power, Power Factor And Frequency Standards - Is 14570 / Iec 60688, Iec61010-1:2010., Current Transducer:Type: Tra, Input Range: 0 -1 A Ac, O / P: Isolated 4- 20 Ma ( Dual ) At 500, Class:0.5, Aux Volts: 240V Ac, 50 Hz, Standards - Is 14570 / Iec 60688, Iec61010-1:2010, Ac Volt Transducers, Din Rail Mounted ( Symmetrical Din, 35Mm ) , Accuracy: 0.5% Of Full Scale, Vaux: 220Vdc, Dual Output:4-20Ma Dc Each, Input Voltage:0-110V, 50Hz, Voltage Input Over Range Capability:1.2 Times Continuous, 2 Times For 5Sec, Standard:Is12784. Standards - Is 14570 / Iec 60688, Iec61010-1:2010, Rish Con P Reactive Power Kvar Transducers, Input : 110 V, 1 A, Dual Output : 4-20 Ma At 750 Ohms, Class : 0.2 Accuracyaux. Supply : 60-300V Ac / Dc, Range : 0-190.52 Var, Standards - Is 14570 / Iec 60688, Iec61010-1:2010, Ac Watt Transducers, Din Rail Mounted ( Symmetrical Din, 35Mm ) , Accuracy:0.5% Of Full Scale, 3-Ph 4-Wire ( 3-Element ) , 50Hz, Vaux: 220Vdc, Dual Output:4-20Ma Dc Each, Input Current:0-1A, Input Voltage:0-110V, Current Input Over Range Capability:1.2 Times Cont., Standards - Is 14570 / Iec 60688, Iec61010-1:2010, Power Factor Transducer ( ( Lag ) 0.5-1-0.5 ( Lead ) ) Nominal Input Current :5A Ac, Nominal Input Voltage : 110V Ac, 50Hz, Aux Supply : 240V Ac, 50Hz, Power Factor Range ( Lag ) 0.5-1-0.5 ( Lead ) Dc Output : 4-12-20Ma Dc, 500 Ohm ( Max ) Class : 0.5, Standards - Is 14570 / Iec 60688, Iec61010-1:2010, Active Power Transducer ( 0-720Mw ) Ctr : 22000A / 5A Ac, Ptr:21Kv / R3 / 110V / R3, Power Range : 0-720Mw, Aux Supply:240V Ac, 50Hz, Dc Output : 4-20Ma Dc, 500 Ohm ( Max ) Class : 0.5, 3Phase 2Element ( 3Phase, 3Watt ) Number Of Outputs : 2, Standards - Is 14570 / Iec 60688, Iec61010-1:2010, Reactive Power Transducer ( -600 -0- +600 Mvar ) Ctr:22000A / 5A, Ptr:21Kv / R3 / 110V / R3, Power Range: ( Lead ) 600-0-600 ( Lag ) Mvar, Aux Supply:240V Ac, 50Hz, Dc Output : 4-12-20Ma Dc, 500 Ohm ( Max ) Class : 0.5, Standards - Is 14570 / Iec 60688, Iec61010-1:2010, Voltage Transducer Along With Digital Panel Meter ( Cut Out144*144 ) , Dual Output, Pt Ratio: 220 Kv / 110 V, Range 0 - 250 Kv / 4-20Ma. Standards - Is 14570 / Iec 60688, Iec61010-1:2010

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 16-03-2023 Extension of Due dates. 23-03-2023
2 23-03-2023 Extension of Due dates. 23-03-2023
3 29-03-2023 Extension of Due dates. 29-03-2023
4 31-03-2023 Extension of Due dates. 29-03-2023

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail