Tender For Providing Fixing Shed To Cover The Basement Ramps, Boom Barrier At Main Entry And Additional Electrical Installations I.E Vacum Circuit Breaker And Foundations In Under Const Building Of P.B.T.I Sector 81, S.A.S Nagar., S.A.S Nagar-Punjab

Public Works Department-PWD has published Tender For Providing Fixing Shed To Cover The Basement Ramps, Boom Barrier At Main Entry And Additional Electrical Installations I.E Vacum Circuit Breaker And Foundations In Under Const Building Of P.B.T.I Sector 81, S.A.S Nagar.. Submission Date for this Tender is 06-03-2023. Barriers Tenders in S.A.S Nagar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

36446902
Tender For Providing Fixing Shed To Cover The Basement Ramps, Boom Barrier At Main Entry And Additional Electrical Installations I.E Vacum Circuit Breaker And Foundations In Under Const Building Of P.B.T.I Sector 81, S.A.S Nagar.
Open Tender
Indian
Punjab
S.A.S Nagar
06-03-2023

Tender Details

Tender For Providing Fixing Shed To Cover The Basement Ramps, Boom Barrier At Main Entry And Additional Electrical Installations I.E Vacum Circuit Breaker And Foundations In Under Const Building Of P.B.T.I Sector 81, S.A.S Nagar.

Key Value

Document Fees
INR 5000 /-
EMD
INR 97198.0 /-
Tender Value
INR 48.59 Lakhs /-

BOQ Items

Name of Work: P/F Shed to cover the Basement Ramps, Boom barrier at main entryand additional electrical installations i.e, Vacum circuit Breaker& Foundations in under const building of P.B.T.ISector-81,S.A.S Nagar.
Sl. No. Item Description
1Providing,Design,Detailed Engineering,Fabrication,Supply,Erection and Installation of Primary Steel Structure Work in mild steel built up tubular SHS/CHS/RHS section including cutting,welding and fixing in position.(i)Applying a two coat of Deco Paint over one coat of Anti Oxide Deco Primer after Rust cleaning process. (ii)Providing,Design and imported shade fabric of weight not less than 920 GSM Fabric,Make Architectonic Belgium. This should also include cutting,welding,and cables,plates and necessary hardware for cut and manufactured with High Frequency PVC welding machine.EASY Technet german Software.(iii) Supply of Belgium make tensile architectural fabric: EASYFLUO PVDF Coated Architectural Membrane(Width of 3 mtrs) Type 2 with minimum wt. of 920 GSM having tensile strength not lessthan 4000 N/50mm/4000 N/50mm(wrap/Weft) and Tear strength not less than 600N/500N(Warp/Weft) of make SIOEN Belgium or equivalent,cables,complete perimeter attachment system and normally associated components.(iv)Automated cutting on ZUND,Switzerland Cutting Machine,manual cutting not permitted High frequency welding on 20KW Firestorm machine with 50mm weld widthX 1400.(v)Mm-Single Stroke.Seamless welding : Weld joints should be sealed for additional Durability(Certificate &Sampleto be submitted1.Designing Conceptual View. (2) Steel Supplying (3) Steel Fabrication & Fabrication.(4) Duco Primer & Paint Supplying (5) Duco Paint Work (6) Total Stn survey of Structure (7) Fabric Designing and Painting.(8)fabric cutting Welding as per Pattern manufacturing.(9) Fabric complete Supplying.(10) fabric Fixing Structure .)
2Providing , Installation, & TestingBoom Gates / Barriers having 6m Length boom Arm with required Accessories. (Model No.-A- BMG01
3Electrical Works Supply installation testing and Commissioning of Non-Extensible 11k ICOG Main Unit, Outdoor type with 1 No. 11kV Load Break Switch and 11kV Vacuum circuit Breakers. Load break switch & Vacuum Circuit breakers shall be of Nominal Voltage 12kV, 630A, 21kA with a Metering Module with PT. Make : ABB/Siemens/Schneider The switching-unit is designed as a three-position-switch. This three-position-switch combines the functions of switch-disconnector and earthing-switch. The switch-disconnector as well as the earthing-switch is equipped with a separate drive-unit. H.T. Compartment – (Load break switch ) – I/C Feeder H.T. Compartment – (Circuit breaker) –O/G Feeder This function-unit consists of a vacuum-circuit breaker in combination with a three-position-switch. The three-position-switch fulfils the operation of the disconnector-function and the earthing-function. The circuit-breaker-unit T2 is equipped with an over current-time-release for the protection 1 Vacuum circuit breaker 12 kV, 21 kA . 1 Stored Energy mechanism for manual operation with integrated earthing switch. 1 Self Powered Electronic numerical protection relay providing over-current & earth fault protection –DPX-V5 relay or equivalent. 3 Ring Core current transformers for protection & metering as per specification ; Dual core ratio 150/1-1A, Cl-1.0 for metering & 5P10 for protection, Burden- 2.5VA. 1 Capacitive voltage indication fixed type - LCD display. 1 ON, OFF, TRIP indication on the front mimic of the panel. 1 Cable box for termination of cable up to 1 No. x 300 sq. mm. 1 Cable cover standard. 1 Emergency Trip Push Button. 1 Digital Ammeter with Selector switch. 1 Operation Counter The following should form the part of the switchgears. a)     2mm Stainless Tank, filled with SF6 comprising of 1 No Isolator and 2 Nos VCB b)    The VCB should be able to clear at least 40 Nos Dead short circuit faults. Breakers clearing less no of faults are not acceptable. c)     Self powered micro processor controlled numeric relay comprising of three over current, one earth fault protection relay. d)    Internal bus earthing with flat GI strip of size 50x6mm. e)     Manual push button for Emergency Trip. f)     Copper/Aluminium bus bar. g)    Manual mechanism. h)     Front access & bottom entry of HT cables. i)      Incase of busbars extension the same should be achieved through “plug-in” busbars only. Bolted type busbars are not acceptable. j)      The cable box should have bottom gland / base plate for cable entry and front cable covers for cable access. k)     The live line indicators should be of LCD/LED display type, due to their higher life; taking the required power form the capacitive coils situated at the cable bushings. l)      Manometer. m)   Mechanical indication in the front on the mimic for Open & Close of Breaker / Isolator / Earth Switch. n)     Operating Handle. o)     The complete switchgear shall be tested for internal arc of 21kA for 0.2 sec AFLR.
4For D.G.Set Foundations Excavation in Soil (any type) using Hydraulic Excavator CK 90 and Tippers with Disposal up to 450 metres. Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead up to 450m.
5Cement Concrete 1:4:8 with stone ballast of size. 40 mm gauge. Using mechanical mixercomplete in all respect as per specifications,drawings and to the entire stasifiction of Engineer - in - charge.
6Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)complete in all respect as per specifcation, drawing and to theentire satisfication of Engineer-In-Charge.
7Reinforced cement concrete M-25 with mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.complete in all respect as per specifications,drawings and to the entire stasifiction of Engineer - in - charge
8Extra for using computerized concrete batch mixing plant including carriage by transit mixer with in 1 km lead. (Note :- where concrete mixer is already included in the rate the same shall be deducted as per item no 10.46 before adding this item)(Rs. 340-216=Rs.124/-)
9Extra for pumping charges of Batch Mix Concrete / Readimix conrete work upto floor 5 levels.
10Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
11Sand filling in foundation and trenches.
Disclaimer :