| Sl. No. | Item Description |
| 1 | Between Lohapatti and Chan : Civil Works |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600 |
| 3 | i) All kinds of Soil |
| 4 | Extra for every additional lift of 1.5m or part thereof in excavation or banking excavated or stacked materials in all kinds of soil |
| 5 | Excavating trenches of required width for pipes, cables etc including excavation for sockets & dressing of sides, ramming of bottoms,depth upto 1.5m including taking out excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing surplus excavated soil as directed, within or outside site at unobjectionable place in all kinds of soil |
| 6 | i) Pipes,cables etc. not exceeding 80mm dia |
| 7 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m |
| 8 | Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. |
| 9 | i) Local Fine Sand within grading zone IV |
| 10 | Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: |
| 11 | iv) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 40mm) |
| 12 | vi) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 40mm) |
| 13 | Centeringand shutteringincludingstrutting,proppingetc. and removal of form work for: |
| 14 | i) Foundations,footings,bases of column |
| 15 | Providing & fixing at or near ground level PRECAST CEMENT CONCRETE in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement:3 coarse sand) including the cost of required centering, shuttering complete. 1:1.5:3 (1 Cement : 1.5 Coarse sand : 3 graded stone aggregate 20mm nominal size) |
| 16 | Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level |
| 17 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
| 18 | Providing & Laying Reinforcedcementconcreteworkinwalls (Any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level UP TO FLOOR V LEVEL excluding cost of centering, shuttering, finishing and reinforcement : |
| 19 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
| 20 | Reinforced cement concrete work in beams, suspended floors, roofshavingslopeupto15°landings,balconies,shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate 20 mm nominal size) |
| 21 | Providing and laying RCC work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 23 | i) Foundations,footings,bases of columns, etc. for mass concrete |
| 24 | v) Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 25 | vii) Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards |
| 26 | viii) Suspended floors, roofs,landings balconies and access platform with water proof ply 12mm thick |
| 27 | ix) Lintels, beams, plinth beams, girders, bressumers cantilevers and with water proof ply 12mm thick |
| 28 | Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels |
| 29 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 |
| 30 | Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth |
| 31 | xiii) Brick work with class designation 5.0 bricks in cement mortar 1:4 (1 cement : 4 coarse sand)IN FOUNDATION AND PLINTH |
| 32 | xiv)Brick work with class designation 5.0 bricks in cement mortar 1:4 (1 cement : 4 coarse sand) in superstructureABOVE PLINTH AND UP TO FLOOR V LEVEL |
| 33 | xvi) Half brick masonry with Class designation 5.0 bricks in Cement mortar 1:4 ( 1 cement : 4 coarse sand) IN superstructureABOVE PLINTH & UP TO FLOOR V LEVEL |
| 34 | Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks |
| 35 | Providingandfixing18mmthickgangsawcutmirrorpolished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. |
| 36 | iv) Granite of any colour and shade having Area of slab over 0.50 sqm |
| 37 | Supplying and fixing of 10mm thick mirror polished black granite tiles for pump island edges etc. over 12mm thick CM 1:4 including cost of all materials and labour etc. complete. |
| 38 | Providing & fixing MS grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc.including priming coat with approved steel primer (fixed to steel windows by welding) all complete. |
| 39 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions,at top, bottom & sides with with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws including fixingall complete as per drawing & the directions of Engineer-in-charge. (Cost of glazing or panels to be paid for separately) |
| 40 | i) Fixed Glazing with Powder coated aluminium (minimum thickness of powder coating 50 micron) sections |
| 41 | iii) For shutters of doors, windows & ventilators with Powder coated aluminium sections including providing fixing hinges/ pivots & making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 42 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): |
| 43 | i) With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 44 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per direction of Engineer in Charge complete Upto 5mm depth and 5mm width |
| 45 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately). |
| 46 | Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: |
| 47 | Supplying and fixing rolling shutters of approved make, madeof required size M.S. laths interlocked together through their entire length,jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS 4454 Part-I & M.S. top cover of required thickness for rolling shutters:- 80x1.25mm MS laths with1.25 mm thick top cover |
| 48 | Providing and fixing ball bearing for rolling shutters. |
| 49 | Extra for providing grilled rolling shutters manufactured out of 8 mm dia. M.S. bar instead of laths as per design approved by Engineer-in- charge.(area of grill to be measured). |
| 50 | Steel work in built up tubular (round,square or rectangular hollow tubes etc) trusses etc. including cutting,hoisting fixing in position and applying a priming coat of approved steel primer, including welded and bolted with special shaped washers etc. complete. |
| 51 | i) Hot finished welded type tubes |
| 52 | Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Tiles of dark shade pigment using ordinary cement |
| 53 | Providing & fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (minimum thickness of 5 mm) of approved make in all colours,shades except burgundy,bottle green,black of any size as approved by Engineer-in-Charge in skirting,risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointinginwhite cementmixed withpigment ofmatchingshade. |
| 54 | Providing & laying Ceramic Glazed floor tiles 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours White, Ivory, Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) jointing with grey cement slurry@ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc. complete. |
| 55 | Providing & laying vitrified floor tile in different sizes (thickness as per manufacturer) with water absorption\"s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar as specified with coarse sand jointing with greycement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete for flooring/skirting as specified |
| 56 | i)Flooring with size of Tiles 60x60Cm in cement mortar 1:4 |
| 57 | iii) Skirting with size of Tiles 60x60Cm in Cement mortar 1:3 |
| 58 | Providing corrugatedG.S. sheet roofingincludingvertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I.limpet washersor with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins,rafters & trusses & including cutting to size & shape wherever required:- 1.00mm thick G.S. Sheet with zinc coating not less than 275gm/m² |
| 59 | Providing and fixing Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of Cold rolled steel confirming to IS:513-2008 of base metal thickness 0.50 mm, having Yield Stress of Min. 275 MPa. Steel surface shall have hot dip metallic coating of Al-Zinc alloy comprising 55% Alluminium, 43.5% Zinc and 1.5% Silicon as per the ASTM-A792M, with total mass of coating on both sides shall be 150 gms/sqm. The steel shall have organic coating with Silicon Modified Polyester (SMP) /Super Durable Polyester (SDP) paint on continuous coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns SMP /SDP paint over 5-7 microns epoxy primer) and back side 8-10 Microns SMP/SDP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.58 MM. Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m or as desired by Engineer-in-charge. |
| 60 | ii) Plain Sheet for Ridges (500 - 600mm). |
| 61 | iii) Plain sheet for Flashings/ Aprons (Upto 600 mm) |
| 62 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. |
| 63 | iii) 160 mm diameter |
| 64 | Providing & fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs,screwed with M.S. screws ofrequired length including cutting brick work & fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 65 | ii) 110 mm |
| 66 | Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure. |
| 67 | Providing & fixing BARE Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) ofbare metal thickness 0.55 mm as per ASTM A446 having yield stress of 275mpa, surface shall have hot dip metallic coating of Aluminium Zinc alloy comprising of 55% aluminium,43.5% zinc & 1.5% silicon, Sheet shall have protective guard film of25 microns minimum to avoid scratches while transportation & should be supplied in single length up to 6m or as desired by Engineer-in-charge. |
| 68 | Providing and laying cement plaster on surfaces with fine sand including curing etc. |
| 69 | ii)12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand) |
| 70 | v)20mm Cement plaster of mix 1:4 (1 cement: 4 fine sand) |
| 71 | Providing and laying 6mm thick cement plaster on surfaces with fine sand including curing etc. |
| 72 | i) 6mm thick plaster of mix 1:3 (1 cement: 3 fine sand) |
| 73 | Providing Neat cement punning |
| 74 | Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 75 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 76 | Finishing walls with water proofing cement paint of required shade with Two or more coats applied @ 3.84 kg/10 sqm: |
| 77 | Finishing walls with Acrylic Smooth exterior paint of required shade (2 or more coat applied @ 1.67 ltr/10 sqm over & including priming coat of exterior Primer applied @ 2.20kg/10 sqm) |
| 78 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture |
| 79 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade with 2 or more coats |
| 80 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 81 | Construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mixer plant at Optimum Moisture Content, carriage of mixed material by tippers to work site, for all lead and lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface & compacting with vibratory power roller to achieve the desired density, complete as per specification & direction of Engineer-in-charge. |
| 82 | iii) With material confirming to grade-III (size 26.5 mm to .075 mm) having CBR value -20, Thickness as desired |
| 83 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to .075 mm) to wet mix macadam (WMM) specifications including premixing the material with water at OMC for all leads and lifts, laying in uniform layers with mechanical paver finisher in sub-base/base course on well prepared surface and compacting with vibratory roller of 8 to 10 ton capacity to achieve the desired density, complete as per specifications & directions of Engineer-in- charge |
| 84 | Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. |
| 85 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 86 | Providing & fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : |
| 87 | ii) 100mm inlet & 75mm outlet SCI S&S as per IS -3989. |
| 88 | Boring/drilling bore well of required dia for casing/ strainer pipe by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, |
| 89 | iv) 300mm dia in all types of soil up to 90m depth below ground |
| 90 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticised PVC medium well casing (CM) pipe of required dia,conforming to IS:12818, including required hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
| 91 | i) 100 mm nominal size dia |
| 92 | Supplying, filling, spreading & levelling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 93 | Supply and packing Gravel in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 94 | Providing & laying factory made Grey / coloured pre-cast cement concrete, interlocking paver block of specified grade made by block making machine wih strong vibratory compaction & of approved size and design / shape, shade and manufacturers and as per IOCL\"s specifications. The paver blocks shall have peripheral chamfer, with average crushing strength as per IS 15658, maximum water absorption of 2% after 10 minutes and 5% after 24 hrs. as per BS 1881 maximum dimensional deviations of +/- 3mm on length @ width and +/- 3 mm on thickness. The job includes supplying and laying a layer of 50 mm thick clean coarse sand on thoroughly compacted sub-base below the paver blocks, cutting the paver blocks wherever required with hydraulic splitter, filling in the joints at the edges of paver blocks with sand, compacting with machine vibrator to required line and level, etc. complete. |
| 95 | ii) M40 grade 80 mm thick Plain finish |
| 96 | Supply and fixing High Density Polymer Water pipe as per IS 4984, PE-63 grade,10Kg/sqcm rating for borewell including all fittings etc |
| 97 | vii) 40mm dia HDPE pipe for borewell upto a depth of 65m |
| 98 | Providing and fixing Chlorinated PolyvinylChloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc. |
| 99 | ii) 20 mm nominal outer dia Pipes |
| 100 | iii) 25 mm nominal outer dia Pipes |
| 101 | iv) 32 mm nominal outer dia Pipes |
| 102 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 103 | i) 25 mm nominal bore |
| 104 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank IS : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 105 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarsesand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 106 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and SW drain pipe 100 mm diameter, 1.8 m long complete as per standard design with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 107 | Providing and fixing 700mm wide rain water gutter fabricated out of 1200mm wide Roll of 18 Gauge Aluminium sheets including MS clamp supports, fittings, fasteners etc. complete as per drawing . (NO joints shall be provided in the gutter and the same has to be fabricated from a continuous roll of Aluminium sheet) |
| 108 | Providing and fixing Stainless steel pipe and fitting of grade AISI 304 as per JIS standard 3448 complete with press type fitting( fitting shall be paid separately) including fixing of the pipe with clamps at 1.00m spacing including cutting and making good the walls including testing of joints complete as/direction of Engineer in charge.(pipe length inserted in the fitting shall not be measured for payment) Exposed on walls or concealed in walls /others |
| 109 | i) 15.88 mm OD SS pipe |
| 110 | iv) 34.00 mm OD SS pipe |
| 111 | v) 42.70 mm OD SS pipe |
| 112 | Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Standards and as approved by Engineer-in-charge : |
| 113 | i) 12mm dia x 300mm long with 75 mm dia x 3 mm thick plate |
| 114 | iv) 20mm dia x 900mm long with 100 mm dia x 6 mm thick plate |
| 115 | v) 25mm dia x 1000mm long with 100 mm dia x 8 mm thick plate |
| 116 | Providing and fixing Chrome Finish SS Health faucet with 8mm dia, 1 meter long SS braided rubber hose pipe and wall hook with N.R.V, Jaguar make cat. No. ALD-577 or equivalent all complete, as per specification and direction of Engineer-in-charge. |
| 117 | Providing and fixing of SS single Soap tray with all fittings and all complete, as per specification and direction of Engineer-in-charge. |
| 118 | Structural steel work riveted, bolted or welded in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 119 | CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items |
| 120 | iv) 3 Core x 2.5 sq. mm Copper Cable FRLS |
| 121 | CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items |
| 122 | xviii) 3.5 Core x 50 sq. mm Aluminium Cable FRLS |
| 123 | Supplying, fabricating and installing following sizes of perforated GI cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling and/or fix to steel/RCC columns, beams or any other structure members with MS suspenders, angles, channels, etc complete as per the direction of IndianOil |
| 124 | i) 100mm x 25mm x 2mm |
| 125 | Supply & drawing/laying, jointing, connecting, testing and commissioning ofearth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : |
| 126 | v) 25 x 3 mm GI strip |
| 127 | Providing & fixing flexible copper cable PVC insulated of 16sqmm for connecting the earth grid/earth strip with the crocodile clip i/c cost of 1 no. crocodile clip (for tanker earthing & other job) |
| 128 | Supplying & Fixing of following items for electrical safety in switch rooms/DG rooms etc |
| 129 | i) Electrical insulating mats made of PVC Elastomer 3mm Thick & 1 mtr wide near swichboards, etc as per direction of Engineer In charge. Mat should conform to IS 15652 Class A - suitable for safe working voltage of upto 33 kV. Test certificate to be provided with supply. Mat\"s top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip. Mat\"s top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip. |
| 130 | ii) 6 mm thick chequered plate on cable trench inside swtich room, DG room, earthing pit including cutting, painting, lifting hooks, etc |
| 131 | iii) Supply and fixing of shock treatment chart in English, Hindi & local language framed in glass framework. |
| 132 | iv) 11 KV grade hand gloves, ISI mark |
| 133 | PROVIDING INTERNAL WIRING |
| 134 | ii) Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 135 | iii) Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. with modular switch, modular plate, suitable GI box |
| 136 | Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make |
| 137 | ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire |
| 138 | v) 2 x 10 sq mm + 1 x 10 sq mm earth wire |
| 139 | SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved includingflush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer\"s specification and direction of Engineer In-charge. |
| 140 | xii) Fan Regulator of stepped modular type |
| 141 | Supplying and fixing of MCB + ELCB (RCBO)with necessery inter connections on existing DB, Panel board. |
| 142 | i) 40 A 2 pole 100-300mA sensitivity |
| 143 | Supply and installation of MCB distribution boardhaving Doubledoorcomplete with tinned cu bus bar, neutral bus bar, earth bar, din bar, interconnection, earthing etc. withoutincoming isolator and MCBs |
| 144 | ii) 2+8 way SPN |
| 145 | Supply and Installation of Flame Proof ESD Push Button |
| 146 | CEILING FANS Supply & fixing of ceiling fan for inside of the sales building of following type: |
| 147 | iii) 1200 mm sweep |
| 148 | EXHAUST FANS Supply and fixing of exhaust fan including electrical wiring all shall be with per specification and direction of site In charge. The fans shall be with louvers / shutters. (The job does notinclude making suitable cut out in thewall for fixing the fan). |
| 149 | ii) 9\" dia light duty, make Khaitan or equivalent |
| 150 | SUBMERSIBLE PUMP Supply,erection,testing & Commissioning of foll.submersible water pump with starter panel board, non return valve, gate valve etc. complete. |
| 151 | ii) 33 LPM 100m head |
| 152 | Supplying and fixing of Earth resistance display board of size 300 X 230 mm with 3mm thick Aluminium Composite Material (ACM)/ Aluminium Composite Panel (ACP) bolted to 25 X 25 X 5 mm (with 2 bolts MS angle section, 60 cm long (minmum 200 mm embedded in ground). The rate shall include supply and pasting of UV resistant vinyl sticker having details as per Engineer-in-charge. |
| 153 | Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watt, having IP65 protection class with Pressure Die Cast Aluminium housing & with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. The LED shall be operating under voltage range of 140-270V with power factor more than 0.9. CCT(Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), CRI (Colour rendering index) not less than 65. LED efficacy should be minimum 100 lumens/watt. The driver shall be of constant volt & constant current type with internal surge protection. Each lot of Fittings shall have serial numbers and accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc. |
| 154 | Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 8 Watt, having IP20 protection class with Pressure Die Cast Aluminium housing & with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. The LED shall be operating under voltage range of 140-270V with power factor more than 0.9. CCT(Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), CRI (Colour rendering index) not less than 65. LED efficacy should be minimum 100 lumens/watt. The driver shall be of constant volt & constant current type with internal surge protection. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports & reference/batch nos of LEDs & fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc. |
| 155 | S/F OF ACP SHEET IN ALUM - DOORS |
| 156 | S/F TOWEL RAIL |
| 157 | Vinyl Sticker at back side of AIR |
| 158 | Ratro glittering sticker for IOCL letter |
| 159 | Handle |
| 160 | S/F of Counter sunk - Wash Basin of size 465x320x150 mm including 305mm Pillar Tap, 32mm Waster Coupling, 300mm Bottle Trap etc. complete - as per Approved Makes |
| 161 | S/F of Wall Hung - WC Pan of size 530x360 mm with soft close seat cover, 40mm Metropole Flush Valve etc. complete |
| 162 | S/F of Urinal of size 375x390x590 mm including 32mm Waste Coupling, 150mm Bottle Trap etc. complete - as per Approved Makes |
| 163 | Supply, Receiving material at site, storing, laying of Heavy Duty type, High compression strength,IP67 rated (DWC) Double wall corrugated Conduits as per IS : 14930/IS:16205 for 63mm OD / 50mm ID. Laying includes with GI pull wires inside the conduits & necessary ends to be filled with sealants or Complete as per detail specifications & as directed by IOCL Officers. |
| 164 | Supply, Receiving material at site, storing, laying of Heavy Duty type, High compression strength,IP67 rated (DWC) Double wall corrugated Conduits as per IS : 14930/IS:16205 for 75 mm OD / 63mm ID. Laying includes with GI pull wires inside the conduits & necessary ends to be filled with sealants or Complete as per detail specifications & as directed by IOCL Officers. |
| 165 | Physically Handicap Handle in Toilet |
| 166 | Supply and fixing of Linear LED(Light Emitting Diode) light fitting of 80 Watt. LED efficacy shall be greater than 100 Lumen/Watt (for luminaire system wattage upto 45W)/120 Lumen/Watt (for luminaire system wattage above 45W) @ 350mA drive current.In respect of LEDs of higher power ratings,drive current greater than 350mA can be accepted if the LED’s LM 80/IS:16105. Outdoor type LED fixtures shall be provided with outdoor weather-proof box with minimum degree of protection IP 65. For detail refer document no. IOCL-LED-TS-1043-R0 & IOCL-LED-RA-1043-R0 |
| 167 | Poly carbonate Sheet For Compressor shed |
| 168 | Between Lohapatti and Chandra: P&M Works |
| 169 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600 |
| 170 | i) All kinds of Soil |
| 171 | Excavating trenches of required width for pipes, cables etc including excavation for sockets & dressing of sides, ramming of bottoms,depth upto 1.5m including taking out excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing surplus excavated soil as directed, within or outside site at unobjectionable place in all kinds of soil |
| 172 | i) Pipes,cables etc. not exceeding 80mm dia |
| 173 | Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. |
| 174 | i) Local Fine Sand within grading zone IV |
| 175 | Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: |
| 176 | iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) |
| 177 | v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm) |
| 178 | Centeringand shutteringincludingstrutting,proppingetc. and removal of form work for: |
| 179 | i) Foundations,footings,bases of column |
| 180 | Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level |
| 181 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
| 182 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 183 | i) Foundations,footings,bases of columns, etc. for mass concrete |
| 184 | Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels |
| 185 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 |
| 186 | Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth |
| 187 | xiii) Brick work with class designation 5.0 bricks in cement mortar 1:4 (1 cement : 4 coarse sand)IN FOUNDATION AND PLINTH |
| 188 | Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks |
| 189 | Providingandfixing18mmthickgangsawcutmirrorpolished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. |
| 190 | iv) Granite of any colour and shade having Area of slab over 0.50 sqm |
| 191 | Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: |
| 192 | Steel work in built up tubular (round,square or rectangular hollow tubes etc) trusses etc. including cutting,hoisting fixing in position and applying a priming coat of approved steel primer, including welded and bolted with special shaped washers etc. complete. |
| 193 | i) Hot finished welded type tubes |
| 194 | Providing and laying cement plaster on surfaces with Coarse sand including curing etc. |
| 195 | ii) 12mm Cement plaster of mix 1:6 (1 cement: 6 coarse sand) |
| 196 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 197 | Finishing walls with water proofing cement paint of required shade with Two or more coats applied @ 3.84 kg/10 sqm: |
| 198 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand or manufacture |
| 199 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 200 | Supply and Laying of 50 mm dia single wall flexible piping system comprising of Non-metallic HDPE (flexible) pipelines as per IOCL specifications and with manufacturer supplied fittings including all bends, tees, elbows, reducers, end connectors at DU & tank side etc and as required for complete underground piping job. The joints in the pipelines, except the end connections at tanks and dispensers shall be made by electro-fusion welding. The pipes shall be suitable for use with petroleum and ethanol blended fuels. The maximum operating pressure shall be 7Kg/sq.cm. Note: The make of HDPE Pipe should be CCOE approved. Pressure testing shall be done before the final backfilling. The civil works for installation viz. excavation, sand filling& back filling etc. shall be paid seperately. All metallic parts in the piping system shall be grounded as per the requirements of EN14125. |
| 201 | Supply and Laying of 80 mm dia single wall flexible piping system comprising of Non-metallic HDPE (flexible) pipelines as per IOCL specifications and with manufacturer supplied fittings including all bends, tees, elbows, reducers, end connectors at DU & tank side etc and as required for complete underground piping job. The joints in the pipelines, except the end connections at tanks and dispensers shall be made by electro-fusion welding. The pipes shall be suitable for use with petroleum and ethanol blended fuels. The maximum operating pressure shall be 7Kg/sq.cm. Note: The make of HDPE Pipe should be CCOE approved. Pressure testing shall be done before the final backfilling. The civil works for installation viz. excavation, sand filling& back filling etc. shall be paid seperately. All metallic parts in the piping system shall be grounded as per the requirements of EN14125. |
| 202 | Structural steel work riveted, bolted or welded in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 203 | Supply, fabrication, laying and testing of MS, BLACK, ERW, threaded pipes, heavy class conforming to IS 1239, PART I as per IOCL specifications including pipeline fittings like bends, tee etc as required and as directed for Underground pipeline with doping |
| 204 | ii) S/L Threaded U/G HD MS Pipes of 80 mm diawith fittings,doping |
| 205 | iii) S/L Threaded U/G HD MS Pipes of 50 mm diawith fittings,doping |
| 206 | Supply, fabrication, laying and testing of MS, BLACK, ERW, threaded pipes, heavy class conforming to IS 1239, PART I as per IOCL Specifications including pipeline fittings like bends, tee etc as required and as directed for Above Ground pipeline including surface preparation according to standard SSPC ST2 and painting with 2 coats of red oxide zinc phosphate primer and 2 coats of Synthetic enamel / aluminium finish paint as per IOCL specifications |
| 207 | ii) S/L Threaded A/G HD MS Pipes of 80 mm dia with fittings,Painting |
| 208 | iv) S/L Threaded A/G HD MS Pipes of 40 mm dia with fittings,Painting |
| 209 | Installation of supplied 20 KL Tank as per specified drawings as per work description but excluding all works of kerb wall and Gasket for manhole including painting / doping with Shalimastic HD as applicable as per specifications complete. |
| 210 | i) In earth pit with RCC strip raft as per standard Drg. ENG/313 (with sand filling) |
| 211 | Supply & welding slip-on flanges conforming to IS2062 GrA, ANSI B16.5, Class#150 with 3 runs of weld outside and one run of weld inside the flanges as per specifications and standard Drg.enclosed herein |
| 212 | i) S/W Slipon flanges of 100 mm dia. conforming to IS2062 GrA, ANSI B16.5,Class 150 as per specifications and standard Drg.enclosed herein |
| 213 | ii) S/W Slipon flanges of80 mm dia conforming to IS2062 GrA, ANSI B16.5,Class 150 as per specifications and standard Drg.enclosed herein |
| 214 | iii) S/W Slipon flanges of 50 mm dia. conforming to IS2062 GrA, ANSI B16.5,Class 150 as per specifications and standard Drg.enclosed herein |
| 215 | Making flanged joints between flanges slip on, blind and flange etc. including providing/supplying 3 mm thick permanite oil gasket, nuts, bolts, bonding with 3 mm dia copper wire etc.complete as per IOCL specifications. |
| 216 | i) Making Flange joint between Slip on,blind and flange etc.of 100mm dia. including gasket, nuts, bolts,3mm dia copper wire bonding |
| 217 | ii) Making Flange joint between Slip on, blind and flange etc.of 80 mm dia. including gasket, nuts, bolts,3mm dia copper wire bonding |
| 218 | iii) Making Flange joint between Slip on,blind and flange etc.of 50 mm dia. including gasket, nuts, bolts,3mm dia copper wire bonding |
| 219 | Supply and installation of ‘U’ type CS bend on the vent pipes including painting as per specifications and supplying and brazingwire mesh of 11 mesh per linear centi-meter of non-corrosive metal in two layers on both ends. |
| 220 | ii) Supply & installation of U type CS bend on vent pipe of 50 mm dia |
| 221 | Supply and installation of screwed type gun metal valves as per IOC specifications: Horizontal Check Valve |
| 222 | i) S/I Screwed type GM Horizontal Check Valve of 50 mm dia |
| 223 | Air compressor Supply and installation of horizontal air compressor assembly with delivery pressure of 12 kg/sq cm equipped with pressure gauge, non- return/safety/drain/delivery valves, automatic cut-off switch and suitable electrical connections & all standard accessories, including civil works: |
| 224 | ii) Horizontal air compressor Assembly of 3 HP (160-220 LITRES) including civil works |
| 225 | Tyre Inflator Supply & installation of Digital tyre inflator which is microprocessor based, automatic air pressure controller with solenoid controlled nozzle for automatic fill and release functions. Complete with weather proof cabinet, 3 digit LED displays with backlight illuminations i.e. one for actual tyre pressure and another for set pressure. Air filter, remote controller, cables, PVC hose pipe and working pressure upto 10bar (Excluding civil work for foundation,etc.) |
| 226 | Transportation of equipmentfrom one location to another location including enroute all taxes, leviesand unloading/loading by a suitable vehicle exclusively for this purpose (In case of tank sameshall be loaded by the tank fabricationcontractor) |
| 227 | vii) Mono/Duo pump/Air Comp/STP/All other pumps - upto 2 nos,0-30 Km |
| 228 | viii) Mono/Duo pump/Air Comp/STP/All other pumps - upto 2 nos, Add extra for every additional Km above 30km |
| 229 | Replacing existing manhole gaskets for 15/20/50/70 KL U/G & A/G tanks including disconnecting the pipelines, removing nuts, bolts & manhole cover and supplying and fixing permanite oil gaskets, nuts & bolts and reconnecting the pipeline. |
| 230 | Supply and fixing Pressure Vacuum Valves of 2 inches for fixing to the Vent Pipes of Underground MS tanks. The valve should be in closed position at normal operating pressure of the tank. The Valve shall be capable for activation at set pressure of 3\" ± 0.5 water column to release excess pressure of tank to the atmosphere and open at vacuum of 8\" ± 2.0 water column to induce the atmosphere pressure to the tank. PV valve should be diaphragm of dead weight or spring loadedtype or combination of any. The weight of the PV valve shall not exceed 2.0 kg. top of the valve shall be provided with cover/cap/ weather hood to prevent the entry of rain water. Valve material,Coverand adopter shall be of Aluminium/polypropylene, diaphragm if used should be of Neoprene, O ring should be of rubber/neoprene, Net/Mesh Pressure puppet ,Vacuum puppet,screws and spring should be of stainless steel. Suitable adopter with one end fitted with valve and the other end should have threading for fixing on Vent pipe of 40mm. PV valves shall have: UL 842 certification of CARB approval or test certificate from any Govt.lab. PV valve shall have PESO approval. |
| 231 | Supplying & drawing inside the poles 3 core 2.5 sq.mm PVC insulated flexible copper conductor, fixing of junction box at the pole base (excluding supply of JB), making all connections on both ends, all complete as per specification and direction of Engineer In-charge. |
| 232 | i) \"Y\" Pole |
| 233 | ii) \"L\" Pole |
| 234 | CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items |
| 235 | iii) 3 Core x 1.5 sq. mm. (copper) |
| 236 | iv) 3 Core x 2.5 sq. mm Copper Cable FRLS |
| 237 | SUPPLY AND LAYING OF FLAT CABLES |
| 238 | i) 3core, 2.5 sq.mm copper Flat Cable for submersible pump |
| 239 | FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. |
| 240 | vii) 3 Core x 2.5 sq. mm |
| 241 | xviii) 3.5 Core x 50 sq. mm |
| 242 | Chemical Earthing with Copper Bonded Rod suitable for current carrying capacity of 15kA for 1 second - Supply of chemical earthing Cu Bonded High Tensile Low Carbon Steel Rod of dia not less than 17mm electrode complying to UL 467 Requirements & suitable for current carrying capacity of 15kA for 1 second, exothermic welded & 3Mtr long |
| 243 | Supply & drawing/laying, jointing, connecting, testing and commissioning ofearth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : |
| 244 | i) 50 x 10mm G.I. Strip |
| 245 | ii) 32 x 6 mm G.I.strip |
| 246 | iii) 50 x 6 mm G.I. Strip |
| 247 | v) 25 x 3 mm GI strip |
| 248 | vii) 10 S.W.G. G.I. Wire (bare) |
| 249 | Providing & fixing flexible copper cable PVC insulated of 16sqmm for connecting the earth grid/earth strip with the crocodile clip i/c cost of 1 no. crocodile clip (for tanker earthing & other job) |
| 250 | PANEL BOARDS AND DISTRIBUTION BOARDS Supply, installation, testing and commissioning of cubicle type power and motor control centre panel fabricated out of 14 SWG sheet steel undergone 7 tank process,dust & vermin proof, floor mounting type, suitable for indoor use having cable entry from the bottom and having following specific components complete, control wiring etc. as per enclosed standard drawing. Any other components/hardware required to complete the panels but not mentioned here shall also be provided. Note: Both incomers should have mechanical interlock for proper & safe operation. The MCCB used for incomer feeder shall have short circuit, overload and earthfault protection and also shunt coil for ESD operation. The Bus Bar support shall be DMC/ SMC/Epoxy moulded. All equipment/components shall be mounted logically to have free access for maintenance, tightening of connections & visual inspection. All the metering equipment shall be Digital & mounted on the panel and size of meter shall be 96 mm x 96 mm. The Bus Bar shall be provided with heat shrunk PVC sleeves & all power terminals shall be stud type with properly shrouding to avoid accidental contact. Neoprene type gasket shall be provided at the doorof the panel. The enclosure of the Panel shall have IP52 degree of protection. 2 Nos earth terminal shall be provided at the Panel frame with extension link for earthing connections. Painting:The under surface shall be prepared by applying a coat of phosphate paint and coat of yellow zinc chromate primer. The under surface shall be made free from all imperfections before undertaking the finishing coat. After preparation of the under surface, the switchboard shall be spray painted with two coats of epoxy based final paint or shall be powder coated. Colour shade of final paint shall be RAL 7032. |
| 251 | Medium RO, Standard drawing No. ENG/IOCL/PDIL-2. List of Componets are: (a) 1 No. MCCB (3P+N) of 100 A, 35 KA with O/L, E/F & S/C Releases for incomer from Electricity Board (b) AC Digital Voltmeter (0-500V) with built in selector switch for incomer from Electricty Board (c) AC Digital Ammeter (0-100A) with built in selector switch for incomer from Electricity Board (d) 1 No. FP, On Load, 100 A, Manually Operated Change over switch suitable for connection of Mains supply and 30 KVA DG Set /5 KW Solar system with required No. of MCCB (100 A,35 KA,3P+N) for change over between Mains supply and DG Set /Solar Supply along with 2 Nos 6A , SP, Control MCB with Indicating lamps. (e) 1 No. MCCB (3P+N) of 100A, 35 KA with UV coilO/L , E/F & S/C Releases for incomer from Electricity Board/DG Set/Solar Supply & 1 No 6A , SP, Control MCB with 3 Nos LED Type (RYB) Indicating lamps (f) 3 Nos 100/5 A CL1 10VA Current Transformers ; PT (50 VA) along with 2 A control fuse link and 1 No. 6A , SP, Control MCB (g) 1 No DP MCB of 40 A, 10 KAfor supply of essential loads (h) 1 No Single Phase Contactor(3NO+3NC) for supply to essential loads (i) 1 No MCB DB Hosuing 6 Nos , 16 A, 10 KA DP MCB as outgoings for essential loads (j) 415 V, TP & N, 125 A, Al Bus Bar (k) 4 Nos MCB (3P+N) of 40 A,10 KA for supply of outgoing feeders 1-4 (l) 9 Nos DP MCB of 10 A, 10 KA in Outgoing Feeder -1 (m) 6 Nos DP MCB of 16 A, 10 KA & 3 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-2 (n) 3 Nos DP MCB of 16 A, 10 KA & 6 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-3 (o) 8 Nos TP MCB of 16 A, 10 KA & 1 Nos TP MCB of 25 A, 10 KA in outgoing Feeder-4 (p) Provision for Termination of Solar Power (Up to 10 KW) Incomer to Essential DB in Panel as per requirement ofIOCL. |
| 252 | Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make |
| 253 | ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire |
| 254 | Supplying and fixing of MCB + ELCB (RCBO)with necessery inter connections on existing DB, Panel board. |
| 255 | ii) 40A 4 pole 100-300mA sensitivity |
| 256 | INSTALLATION OF SD/HD DISPENSING PUMPS (MONO /DUAL) Installation of supplied standard duty/heavy duty dispensing pump on existing pump island as per IOCL\"s drawings and instructions including supplying /filling required quantity of dry sand in the pit(s) belowthe pump |
| 257 | i) Installation of DU Including providing necessary anchor bolts and C.C. foundation |
| 258 | Supplying and fixing 12 volt Charged LA battery of approved make for Electronic dispensing pumps including giving necessery electrical connectionfor thefollowing AH ratings. |
| 259 | i) S/I of 12 Volt, 7AH Charged LA battery of approved make with stand |
| 260 | OCTAGONAL POLES Supply & Fixing of Octagonal Poles of following type (Civil job shall be paid separatly) : |
| 261 | iii) S/E of 5 Meter high galvanised Octagonal pole with top 60mm(A/F), bottom 130mm (A/F) made up of 3 mm thick plate having a base plate of size 210 x 210 x 12 with single arm 1500mm long bracket arm made up of 48 O.D. pipe with EN 8 grade galvanised foundation bolts and anchor plate on suitable concrete foundation as per standard drawings enclosed herein(Civil & Electrical works shall be paid separately) having fixing arrangement for mounting 2 Nos. of 250W Metal halide luminaries (on opposite sides) |
| 262 | Supply, fitting, fixing of arm bracket, tubular type, 38mm/50mm dia on pole including painting, all complete. |
| 263 | ii) S/EArm \" Y \" bracket 38/50mm dia on pole, as per specifications and direction of Engineer in charge |
| 264 | Supply and fixing of 100 W LED (Light Emitting Diode) light fixture with fittings and accessories for Yard lighting purpose having IP66 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. |
| 265 | DISPENSING PUMP CONNECTIONS |
| 266 | ii) Providing dispensing pump power circuit connection with copper conductor single core PVC sheathed wire as per recommendationsof the pump manufacturer (make of pumps: L&T /MIDCO /AVERY / Tatsuno/ Nouvopignone) |
| 267 | Intelligent Line Conditioner (ILC),Supply, Installation and Commissioning of IGBT based Static Voltage Stabilizer of Capacity 15kVA Three Phase with three phase surge protection device and Manual bypass switch; Voltage regulation done by High Frequency(20kHz) PWM driven IGBT.ensuring that the output voltage complies with the requirements of ITIC curve for regulated voltage supply to electronic machineryby superimposing generated wave on input wave, without any break or switching in the power path, current interruption, transition or step changingNo moving part like Relay or Brush to be used for voltage regulation; The Architecture to be fully Solid State; The output voltage must be free of harmful all spikes and EMI/RFI noises; Full Regulation Input Voltage Range 170-290VAC L-N: 295-505VAC L-L; Full Regulation Output Voltage 230VAC L-N ±1%: 400VAC L-L ±1%; Relaxed Regulation Input Voltage Range 140-300VAC L-N: 245-515VAC L-L; Relaxed Regulation Output Voltage 200-240VAC L-N; Operation Frequency 47-53Hz; Correction Speed at least 6000V/s; Efficiency at least 96% even at partial load; MCB at Input; Contactor at Output; Manual Bypass Switch; Overload, Short- Circuit, Double Phase, Overvoltage (at 300VAC L-N), Undervoltage (at 140VAC L-N) Protections; Class II Surge Protection on all three phases independently, for at least 6kV, 8x20??s waveform; Ingress Protection at least IP20; Class H Insulation for Galvanic Components; Digital Annunciation for status; Operating Temperature 0-60° C |
| 268 | Supply & Fixingof EarthingClip Box of Size 200x300x400 mm for keeping crocodile clip |