}

Tender For New A Site Ksk At Location Within 5 Km From Bansada Towards Sadanandpur Dist Bhadrak Under Bhubaneswar Do Of Odisha So, bansada-Odisha

Indian Oil Corporation Limited-IOCL has published Tender For New A Site Ksk At Location Within 5 Km From Bansada Towards Sadanandpur Dist Bhadrak Under Bhubaneswar Do Of Odisha So. Submission Date for this Tender is 28-02-2023. Land Development Tenders in bansada Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

36374292
Tender For New A Site Ksk At Location Within 5 Km From Bansada Towards Sadanandpur Dist Bhadrak Under Bhubaneswar Do Of Odisha So
Limitted
Indian
Odisha
bansada
28-02-2023

Tender Details

New A Site Ksk At Location Within 5 Km From Bansada Towards Sadanandpur Dist Bhadrak Under Bhubaneswar Do Of Odisha So => Limited

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 91.85 Lakhs /-

BOQ Items

NAME OF WORK: Development of New A Site KSK at Location Within 5 km From Bansada Towards Sadanandpur, Dist : Bhadrak underBhubaneswar Divisional Office of Odisha State Office
Sl. No. Item Description
1Civil Works ITC NIL (A)
2Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600
3i) All kinds of Soil
4Extra for every additional lift of 1.5m or part thereof in excavation or banking excavated or stacked materials in all kinds of soil
5Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete.
6i) Local Fine Sand within grading zone IV
7Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
8iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm)
9v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm)
10Centeringand shutteringincludingstrutting,proppingetc. and removal of form work for:
11i) Foundations,footings,bases of column
12Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level
13ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
14Providing & Laying Reinforcedcementconcreteworkinwalls (Any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level UP TO FLOOR V LEVEL excluding cost of centering, shuttering, finishing and reinforcement :
15ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
16Centering and shuttering including strutting, propping etc. and removal of form for :
17i) Foundations,footings,bases of columns, etc. for mass concrete
18iii) Suspendedfloors,roofs,landings,balconies, access platform and Shelves (Cast in situ)
19iv) Lintels, beams plinth beams,girders bressumers and cantilevers
20v) Columns, Pillars, Piers, Abutments, Posts and Struts.
21vii) Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards
22Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
23ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
24Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
25ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
26viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH
27xiii) Brick work with class designation 5.0 bricks in cement mortar 1:4 (1 cement : 4 coarse sand)IN FOUNDATION AND PLINTH
28Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in:
29i) 1 Cement mortar 1:4 (1 cement : 4 coarse sand)
30Providing & fixing MS grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc.including priming coat with approved steel primer (fixed to steel windows by welding) all complete.
31Supplying and fixing rolling shutters of approved make, madeof required size M.S. laths interlocked together through their entire length,jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS 4454 Part-I & M.S. top cover of required thickness for rolling shutters:- 80x1.25mm MS laths with1.25 mm thick top cover
32Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Tiles of dark shade pigment using ordinary cement
33Providing & fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (minimum thickness of 5 mm) of approved make in all colours,shades except burgundy,bottle green,black of any size as approved by Engineer-in-Charge in skirting,risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointinginwhite cementmixed withpigment ofmatchingshade.
34Providing & laying Ceramic Glazed floor tiles 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours White, Ivory, Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) jointing with grey cement slurry@ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc. complete.
35Providing & laying vitrified floor tile in different sizes (thickness as per manufacturer) with water absorption"s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar as specified with coarse sand jointing with greycement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete for flooring/skirting as specified
36i)Flooring with size of Tiles 60x60Cm in cement mortar 1:4
37Providing and laying cement plaster on surfaces with fine sand including curing etc.
38i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)
39Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes.
40ii) 110 mm diameter
41Providing and laying 6mm thick cement plaster on surfaces with fine sand including curing etc.
42i) 6mm thick plaster of mix 1:3 (1 cement: 3 fine sand)
43Providing Neat cement punning
44Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete
45Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
46Finishing walls with Acrylic Smooth exterior paint of required shade (2 or more coat applied @ 1.67 ltr/10 sqm over & including priming coat of exterior Primer applied @ 2.20kg/10 sqm)
47Finishing walls with Deluxe Multi surface paint system for interiors & exteriors using Primer as per manufacturers specifications with two or more coats applied on wall @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm
48Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
49Construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mixer plant at Optimum Moisture Content, carriage of mixed material by tippers to work site, for all lead and lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface & compacting with vibratory power roller to achieve the desired density, complete as per specification & direction of Engineer-in-charge.
50iii) With material confirming to grade-III (size 26.5 mm to .075 mm) having CBR value -20, Thickness as desired
51Extraforcompaction of earth work in embankmentunder optimum moisture conditions to give at least 95% of the maximum dry density (proctor density).
52Supply and laying of water bound macadam of 100 mm consolidated thickness for subbase with 90 to 45 mm stone aggregate,11.2mm size screenings, chippings of stone and murrum spreading, watering and consolidating in camber with power roller complete as/specifications.
53Supply and laying of water bound macadam in layers, each of 75 mm thick (consolidated) with 63 mm to 45 mm stone aggregate. Each layer shall be consolidated by power roller after watering, spreading chippings of stone and murrum complete as per specifications. Item includes supply of murrum 6 mm thick, watering and rolling with power roller complete with preparation of surface. Rate per Layer
54Providing & laying factory made Grey / coloured pre-cast cement concrete, interlocking paver block of specified grade made by block making machine wih strong vibratory compaction & of approved size and design / shape, shade and manufacturers and as per IOCL"s specifications. The paver blocks shall have peripheral chamfer, with average crushing strength as per IS 15658, maximum water absorption of 2% after 10 minutes and 5% after 24 hrs. as per BS 1881 maximum dimensional deviations of +/- 3mm on length @ width and +/- 3 mm on thickness. The job includes supplying and laying a layer of 50 mm thick clean coarse sand on thoroughly compacted sub-base below the paver blocks, cutting the paver blocks wherever required with hydraulic splitter, filling in the joints at the edges of paver blocks with sand, compacting with machine vibrator to required line and level, etc. complete.
55ii) M40 grade 80 mm thick Plain finish
56Providing and fixing water closet squatting pan (Indian type W.C.pan) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C.flushing cistern including flush pipewith manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required -White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests.
57Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P.flush bend with fittings & C.I.brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
58i) W.C. pan with ISI marked white solid plastic seat and lid
59Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required :
60ii) White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap
61Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
62Providing and fixing plain bend of required degree.
63ii) 75mm dia Sand cast iron S&S as per IS - 3989
64Providing and fixing double equal junction of required degree with accessdoor, insertion rubber washer 3 mm thick, bolts and nuts complete :
65ii) 75x75x75x75 mm SCI S&S as per IS - 3989
66Providing and fixing soil, waste and vent pipes :
67iii) 75mm dia Sand cast iron S&S pipe as per IS: 1729
68Providing & fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :
69i) 100mm inlet & 100mm outlet SCI S&S as per IS -3989.
70Providing and fixing Chlorinated PolyvinylChloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc.
71i) 15 mm nominal outer dia Pipes
72ii) 20 mm nominal outer dia Pipes
73Providing and fixing brass bib cock of approved quality :
74i) 15 mm nominal bore
75Providing and fixing brass stop cock of approved quality :
76i) 15 mm nominal bore
77Providing and laying non-pressure NP3 class (Medium class) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc.complete
78ii) 900 mm dia. R.C.C. pipe
79Providing & fixing in position pre-cast R.C.C. manhole cover & frame of reqd. shape & approved quality(Light/medium/heavy/extra heavy duty)
80i) L D- 2.5,Rectangular shape 600x450mm internal dimensions
81ii) L D- 2.5,Square shape 450mm internal dimensions
82Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and SW drain pipe 100 mm diameter, 1.8 m long complete as per standard design with common burnt clay F.P.S. (non modular) bricks of class designation 7.5
83Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions,at top, bottom & sides with with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws including fixingall complete as per drawing & the directions of Engineer-in-charge. (Cost of glazing or panels to be paid for separately)
84i) Fixed Glazing with Powder coated aluminium (minimum thickness of powder coating 50 micron) sections
85iii) For shutters of doors, windows & ventilators with Powder coated aluminium sections including providing fixing hinges/ pivots & making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
86Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item):
87ii) With float glass panes of 5.0 mm thickness (weight not less than 12.5kg/sqm)
88iii) With float glass panes of 8.0 mm thickness (weight not less than 20kg/sqm)
89Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately).
90PROVIDING INTERNAL WIRING
91ii) Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required.
92iii) Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. with modular switch, modular plate, suitable GI box
93Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make
94ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire
95iii) 2 x 4 sq mm + 1 x 4 sq mm earth wire
96Supply and fixing of following Electrical fittings /fixtures
97ii) 5 Amp modulartypeswitch
98iv) 15Ampmodular typeswitch
99v) 15Ampmodular type6 pin socket
100SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved includingflush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer"s specification and direction of Engineer In-charge.
101iii) 4 module frame
102iv) 6 module frame
103vi) 12 module frame
104xii) Fan Regulator of stepped modular type
105SWITCH FUSE UNIT WITHOUT FUSE Supply & fixing switches/accessories in sheet metal enclosureincludingproviding of required connections with supply of necessarycable/conduits as required in case of existing control switch panel/ switch board etc. all complete as per specification and direction of Engineer-In-Charge.( SFUs shall be of approved make and SFUs shall be without fuse)
106vi) 100Amp TPN switch fuse unit
107MINIATURE CIRCUIT BREAKERS (MCB) Supplying & fixing of Miniature Circuit Breakers as per approved make of 10KA Breaking cpacity of following ratings
108iii) 6A to 32A DP MCB
109CEILING FANS Supply & fixing of ceiling fan for inside of the sales building of following type:
110iii) 1200 mm sweep
111Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 8 Watt, having IP20 protection class with Pressure Die Cast Aluminium housing & with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. The LED shall be operating under voltage range of 140-270V with power factor more than 0.9. CCT(Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), CRI (Colour rendering index) not less than 65. LED efficacy should be minimum 100 lumens/watt. The driver shall be of constant volt & constant current type with internal surge protection. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports & reference/batch nos of LEDs & fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc.
112Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watt, having IP65 protection class with Pressure Die Cast Aluminium housing & with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. The LED shall be operating under voltage range of 140-270V with power factor more than 0.9. CCT(Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), CRI (Colour rendering index) not less than 65. LED efficacy should be minimum 100 lumens/watt. The driver shall be of constant volt & constant current type with internal surge protection. Each lot of Fittings shall have serial numbers and accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc.
113S/F OF ACP SHEET IN ALUM DOORS/Column Cl
114S/F TOWEL RAIL
115S/F SOAP TRAY
116NON Civil Works ITC 100 (B)
117Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600
118i) All kinds of Soil
119Extra for every additional lift of 1.5m or part thereof in excavation or banking excavated or stacked materials in all kinds of soil
120FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
121vii) 3 Core x 2.5 sq. mm
122Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m
123Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
124iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm)
125v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm)
126Centeringand shutteringincludingstrutting,proppingetc. and removal of form work for:
127i) Foundations,footings,bases of column
128Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level
129ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
130Centering and shuttering including strutting, propping etc. and removal of form for :
131i) Foundations,footings,bases of columns, etc. for mass concrete
132Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
133ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
134Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
135ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
136Providingandfixing18mmthickgangsawcutmirrorpolished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels.
137iii) Granite of any colour and shade having Area of slab upto 0.50 sqm
138iv) Granite of any colour and shade having Area of slab over 0.50 sqm
139Supplying and fixing of 10mm thick mirror polished black granite tiles for pump island edges etc. over 12mm thick CM 1:4 including cost of all materials and labour etc. complete.
140Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
141Painting on G.S. sheet with synthetic enamel paint of approved brand & manufacture of required colour to give an even shade, 2 or more coats,including a coat of approved steel primer but excluding a coat of mordant solution
142Boring/drilling bore well of required dia for casing/ strainer pipe by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge,
143iv) 300mm dia in all types of soil up to 90m depth below ground
144xvi) 300mm dia in all types of soil 90m to 150m depth
145Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticised PVC medium well casing (CM) pipe of required dia,conforming to IS:12818, including required hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
146ii) 150 mm nominal size dia
147Supplying, filling, spreading & levelling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
148Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/ plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire and labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge.
149i) 100 mm nominal size dia having minimum wall thickness 5.00mm
150Providing and fixing Chlorinated PolyvinylChloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall
151i) 15 mm nominal outer dia Pipes
152iv) 32 mm nominal outer dia Pipes
153Providing and placing on terrace (at all floor levels) polyethylene water storage tank IS : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
154Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Standards and as approved by Engineer-in-charge :
155v) 25mm dia x 1000mm long with 100 mm dia x 8 mm thick plate
156Supply, fabrication, laying and testing of MS, BLACK, ERW, threaded pipes, heavy class conforming to IS 1239, PART I as per IOCL Specifications including pipeline fittings like bends, tee etc as required and as directed for Above Ground pipeline including surface preparation according to standard SSPC ST2 and painting with 2 coats of red oxide zinc phosphate primer and 2 coats of Synthetic enamel / aluminium finish paint as per IOCL specifications
157iv) S/L Threaded A/G HD MS Pipes of 40 mm dia with fittings,Painting
158Supply, fabrication, laying and testing of MS black, ERW welded, pipes, heavy class conforming to IS 1239, PART I as per IOCL specifications including pipeline fittings like bends, tee etc as required and as directed for Underground pipeline with doping
159ii) S/L Welded U/G HD MS Pipes of 80mm dia with fittings,doping
160Supply & welding slip-on flanges conforming to IS2062 GrA, ANSI B16.5, Class#150 with 3 runs of weld outside and one run of weld inside the flanges as per specifications and standard Drg.enclosed herein
161iii) S/W Slipon flanges of 50 mm dia. conforming to IS2062 GrA, ANSI B16.5,Class 150 as per specifications and standard Drg.enclosed herein
162Supplying and installation of the following threaded Union conforming to detailed specification
163ii) S/I of Threaded Union of 50 mm
164Supplying and installation of the following threaded coupling
165i) 80 mm dia Aluminium camlock coupling - Male only
166Supply and installation of ‘U’ type CS bend on the vent pipes including painting as per specifications and supplying and brazingwire mesh of 11 mesh per linear centi-meter of non-corrosive metal in two layers on both ends.
167iii) Supply & installation of U type CS bend on vent pipe of 40 mm dia
168Installation of supplied Multi Product Pumps / Dispensers on pump island as per manufacturers installation manual, drawings, including supplying, providing necessary frame of ISMC 100, foundation bolts, supplying and filling required quantity of dry sand in pit(s) below the pump
169i) 2 product - 4 nozzle MPPs/MPDs
170Air compressor Supply and installation of horizontal air compressor assembly with delivery pressure of 12 kg/sq cm equipped with pressure gauge, non- return/safety/drain/delivery valves, automatic cut-off switch and suitable electrical connections & all standard accessories, including civil works:
171iii) Horizontal air compressor Assembly of 5 HP (160-220 LITRES) including civil works
172Tyre Inflator Supply & installation of Digital tyre inflator which is microprocessor based, automatic air pressure controller with solenoid controlled nozzle for automatic fill and release functions. Complete with weather proof cabinet, 3 digit LED displays with backlight illuminations i.e. one for actual tyre pressure and another for set pressure. Air filter, remote controller, cables, PVC hose pipe and working pressure upto 10bar (Excluding civil work for foundation,etc.)
173Supply and Laying of 50 mm dia single wall flexible piping system comprising of Non-metallic HDPE (flexible) pipelines as per IOCL specifications and with manufacturer supplied fittings including all bends, tees, elbows, reducers, end connectors at DU & tank side etc and as required for complete underground piping job. The joints in the pipelines, except the end connections at tanks and dispensers shall be made by electro-fusion welding. The pipes shall be suitable for use with petroleum and ethanol blended fuels. The maximum operating pressure shall be 7Kg/sq.cm. Note: The make of HDPE Pipe should be CCOE approved. Pressure testing shall be done before the final backfilling. The civil works for installation viz. excavation, sand filling& back filling etc. shall be paid seperately. All metallic parts in the piping system shall be grounded as per the requirements of EN14125.
174Transportation of equipmentfrom one location to another location including enroute all taxes, leviesand unloading/loading by a suitable vehicle exclusively for this purpose (In case of tank sameshall be loaded by the tank fabricationcontractor)
175xi) MPD/MPP pumps upto 2 nos., 0-30 Km
176xii) MPD/MPP pumps upto 2 nos., Add extra for every additional Km above 30km
177Replacing existing manhole gaskets for 15/20/50/70 KL U/G & A/G tanks including disconnecting the pipelines, removing nuts, bolts & manhole cover and supplying and fixing permanite oil gaskets, nuts & bolts and reconnecting the pipeline.
178Supply and fixing Pressure Vacuum Valves of 2 inches for fixing to the Vent Pipes of Underground MS tanks. The valve should be in closed position at normal operating pressure of the tank. The Valve shall be capable for activation at set pressure of 3" ± 0.5 water column to release excess pressure of tank to the atmosphere and open at vacuum of 8" ± 2.0 water column to induce the atmosphere pressure to the tank. PV valve should be diaphragm of dead weight or spring loadedtype or combination of any. The weight of the PV valve shall not exceed 2.0 kg. top of the valve shall be provided with cover/cap/ weather hood to prevent the entry of rain water. Valve material,Coverand adopter shall be of Aluminium/polypropylene, diaphragm if used should be of Neoprene, O ring should be of rubber/neoprene, Net/Mesh Pressure puppet ,Vacuum puppet,screws and spring should be of stainless steel. Suitable adopter with one end fitted with valve and the other end should have threading for fixing on Vent pipe of 40mm. PV valves shall have: UL 842 certification of CARB approval or test certificate from any Govt.lab. PV valve shall have PESO approval.
179Installation of supplied 20 KL Tank as per specified drawings as per work description but excluding all works of kerb wall and Gasket for manhole including painting / doping with Shalimastic HD as applicable as per specifications complete.
180vi) In brick masonry pit with RCC matt under driveway including RCC top slab as per standard Drg. ENG/318. Manhole cover plates and frame to be paid separately. (with sand filling)
181CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
182i) 2 Core x 1.5 sq. mm. (copper)
183iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
184SUPPLY AND LAYING OF FLAT CABLES
185i) 3core, 2.5 sq.mm copper Flat Cable for submersible pump
186CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compressoncable glands, crimping type lugs and allied jointing materials, etc. all complete as per specificationand direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
187vii) 3 Core x 2.5 sq. mm
188FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination(FLP):Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of FLP heavy duty double compression cable glands, Baliga/CEAG-FCG /Flexpro/ FEPL make, crimping lugs and allied jointing materials, etc. all complete as per specification & direction of Engineer In-charge. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
189i) 2 Core x 1.5 sq. mm
190ii) 2 Core x 2.5 sq. mm
191Supply & drawing/laying, jointing, connecting, testing and commissioning ofearth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following :
192ii) 32 x 6 mm G.I.strip
193v) 25 x 3 mm GI strip
194Supplying and fixing of following MCBs with necessery inter connectionson existing DB, Panel board etc.
195i) Upto 32A SP MCB
196CONSTANT VOLTAGE TRANSFORMER Supplying, installation, testing and commissioning of single phase, air cooled constant voltage transformer of approved make having input voltage range of 180-260V and output voltage of 220/230V with sine wave output wave form and having automatic current limiting and short circuit protectionincluding all accessories complete (for displays) for the following VA ratings.
197iii) 500VA CVT
198OCTAGONAL POLES Supply & Fixing of Octagonal Poles of following type (Civil job shall be paid separatly) :
199i) S/E of 7 Meter high galvanised Octagonal pole with top 70mm (A/F), bottom 130mm (A/F) made up of 3 mm thick plate having a base plate of size 220 x 220 x 12 with single arm 1500mm long bracket arm made up of 48 O.D. pipe with EN 8 grade galvanised foundation bolts and anchor plate on suitable concrete foundation as per standard drawings enclosed herein(Civil & Electrical works shall be paid separately) having fixing arrangement for mounting 2 Nos. of 250W Metal halide luminaries (on opposite sides)
200DISPENSING PUMP CONNECTIONS
201ii) Providing dispensing pump power circuit connection with copper conductor single core PVC sheathed wire as per recommendationsof the pump manufacturer (make of pumps: L&T /MIDCO /AVERY / Tatsuno/ Nouvopignone)
202SUBMERSIBLE PUMP Supply,erection,testing & Commissioning of foll.submersible water pump with starter panel board, non return valve, gate valve etc. complete.
203ii) 33 LPM 177m head
204Supply and fixing of 30 W LED (Light Emitting Diode) light fixture with fittings and accessories for hoarding light purposes having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc.
205Supply and fixing of 100 W LED (Light Emitting Diode) light fixture with fittings and accessories for Yard lighting purpose having IP66 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc.
206Chemical Earthing with Copper Bonded Rod suitable for current carrying capacity of 15kA for 1 second - Supply of chemical earthing Cu Bonded High Tensile Low Carbon Steel Rod of dia not less than 17mm electrode complying to UL 467 Requirements & suitable for current carrying capacity of 15kA for 1 second, exothermic welded & 3Mtr long
207Supply & welding slip-on flanges conforming to IS2062 GrA, ANSI B16.5, Class#150 with 3 runs of weld outside and one run of weld inside the flanges as per specifications and standard Drg.enclosed herein
208ii) S/W Slipon flanges of80 mm dia conforming to IS2062 GrA, ANSI B16.5,Class 150 as per specifications and standard Drg.enclosed herein
209Making flanged joints between flanges slip on, blind and flange etc. including providing/supplying 3 mm thick permanite oil gasket, nuts, bolts, bonding with 3 mm dia copper wire etc.complete as per IOCL specifications.
210ii) Making Flange joint between Slip on, blind and flange etc.of 80 mm dia. including gasket, nuts, bolts,3mm dia copper wire bonding
211Transportation of equipmentfrom one location to another location including enroute all taxes, leviesand unloading/loading by a suitable vehicle exclusively for this purpose (In case of tank sameshall be loaded by the tank fabricationcontractor)
212iii) 15/20 KL Tank with fittings : 0 - 30 Km
213iv) 15/20 KL Tank with fittings: Add extra for each addtnl. Km above 30km
214Providing and laying cement plaster on surfaces with fine sand including curing etc.
215i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)
216Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in:
217i) 1 Cement mortar 1:4 (1 cement : 4 coarse sand)
218Supply & drawing/laying, jointing, connecting, testing and commissioning ofearth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following :
219i) 50 x 10mm G.I. Strip
220Providing & fixing flexible copper cable PVC insulated of 16sqmm for connecting the earth grid/earth strip with the crocodile clip i/c cost of 1 no. crocodile clip (for tanker earthing & other job)
221Supplying & Fixing of following items for electrical safety in switch rooms/DG rooms etc
222i) Electrical insulating mats made of PVC Elastomer 3mm Thick & 1 mtr wide near swichboards, etc as per direction of Engineer In charge. Mat should conform to IS 15652 Class A - suitable for safe working voltage of upto 33 kV. Test certificate to be provided with supply. Mat"s top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip. Mat"s top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip.
223ii) 6 mm thick chequered plate on cable trench inside swtich room, DG room, earthing pit including cutting, painting, lifting hooks, etc
224iii) Supply and fixing of shock treatment chart in English, Hindi & local language framed in glass framework.
225iv) 11 KV grade hand gloves, ISI mark
226PANEL BOARDS AND DISTRIBUTION BOARDS Supply, installation, testing and commissioning of cubicle type power and motor control centre panel fabricated out of 14 SWG sheet steel undergone 7 tank process,dust & vermin proof, floor mounting type, suitable for indoor use having cable entry from the bottom and having following specific components complete, control wiring etc. as per enclosed standard drawing. Any other components/hardware required to complete the panels but not mentioned here shall also be provided. Note: Both incomers should have mechanical interlock for proper & safe operation. The MCCB used for incomer feeder shall have short circuit, overload and earthfault protection and also shunt coil for ESD operation. The Bus Bar support shall be DMC/ SMC/Epoxy moulded. All equipment/components shall be mounted logically to have free access for maintenance, tightening of connections & visual inspection. All the metering equipment shall be Digital & mounted on the panel and size of meter shall be 96 mm x 96 mm. The Bus Bar shall be provided with heat shrunk PVC sleeves & all power terminals shall be stud type with properly shrouding to avoid accidental contact. Neoprene type gasket shall be provided at the doorof the panel. The enclosure of the Panel shall have IP52 degree of protection. 2 Nos earth terminal shall be provided at the Panel frame with extension link for earthing connections. Painting:The under surface shall be prepared by applying a coat of phosphate paint and coat of yellow zinc chromate primer. The under surface shall be made free from all imperfections before undertaking the finishing coat. After preparation of the under surface, the switchboard shall be spray painted with two coats of epoxy based final paint or shall be powder coated. Colour shade of final paint shall be RAL 7032.
227Kisaan Seva Kendra, Standard drawing No. ENG/IOCL/PDIL-3. List of Componets are: (a) 1 No. MCCB (3P+N) of 63 A, 25 KA with O/L, E/F & S/C Releases for incomer from Electricity Board (b) AC Digital Voltmeter (0-500V) with built in selector switch for incomer from Electricty Board (c) AC Digital Ammeter (0-60A) with built in selector switch for incomer from Electricity Board (d) 1 No. FP, On Load, 63 A, Manually Operated Change over switch suitable for connection of Mains supply and 10 KVA DG Set /5 KW Solar system with required No. of MCCB (63 A ,25 KA, 3P+N)for change over between Mains supply and DG Set /Solar Supply along with 2 Nos 6A , SP, Control MCB with Indicating lamps. (e) 1 No. MCCB (3P+N) of 63A, 25 KA with UV coilO/L , E/F & S/C Releases for incomer from Electricity Board/DG Set/ Solar Supply & 1 No 6A , SP, Control MCB with 3 Nos LED Type (RYB) Indicating lamps (f) 3 Nos 60/5 A CL1 10VA Current Transformers ; PT (50 VA) along with 2 A control fuse link and 1 No. 6A , SP, Control MCB (g) 1 No DP MCB of 40 A, 10 KAfor supply of essential loads (h) 1 No Single Phase Contactor(3NO+3NC) for supply to essential loads (i) 1 No MCB DB Hosuing 6 Nos , 16 A, 10 KA DP MCB as outgoings for essential loads (j) 415 V, TP & N, 100 A, Al Bus Bar (k) 4 Nos MCB (3P+N) of 40 A,10 KA for supply of outgoing feeders 1-4 (l) 6 Nos DP MCB of 10 A, 10 KA in Outgoing Feeder -1 (m) 6 Nos DP MCB of 16 A, 10 KA in outgoing Feeder-2 (n) 6 Nos DP MCB of 16 A, 10 KAin outgoing Feeder-3 (o) 6 Nos TP MCB of 16 A, 10 KA in outgoing Feeder-4 (p) Provision for Termination of Solar Power (Up to 10 KW) Incomer to Essential DB in Panel as per requirement ofIOCL.
228Supply and Installation of Flame Proof ESD Push Button
229Providing electric connection from respective State Electricity board/Electric Supply Company, liasoning & correspondences with resp ective electric office on behalf of IOCL. The work includes payment to electric office or to their approved/empanelled contractor asadvised by the electric office for provision of electric connection to Retail Outlet through 11/0.4 KV 25KVA transformer including DP structure, Pole, metering arrangement, testing,termination of power supply cable to IOCL Main Electric Panel complete in all re spect. Transformer to be installed adjacent to the RO premises and extra payment only for the incoming supply cable from transformerto panel will be made extra at actual.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail