| 1 | Stripping and stacking slate or tiles of a roof (8.10) |
| 2 | Dismantling brick work tile masonary or tile lining In cement. (8.5 b) |
| 3 | Centring & shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc (CSR 9.8) |
| 4 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. (CSR - 10.20) |
| 5 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. (CSR - 11.6) |
| 6 | Terracing consisting of tiles 22.86 cm x 11.43 cm x 3.81 cm laid over 25mm mud plaster, 75 mm mud filling on another layer of 25 mm mud plaster including two coats of bitumen laid hot @ 1.65 Kg. per Sqm. on top of R.C.C slab including grouting with cement sand mortar 1:4 and top surface to be left clear after wire brushing etc. (CSR 13.13i) |
| 7 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes single socketed (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS clamps.U-PVC pipes (working pressure 4 kgf. / sqcm)pipe 110 mm dia. (CSR - 13.74 A i) |
| 8 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.. (CSR 13.75a) |
| 9 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. (CSR 13.55) |
| 10 | Plastering on underside of ceiling 10mm thick cement plaster 1:4(CSR 15.44) |
| 11 | 12.5 mm thick cement plaster 1:4 (CSR 15.9) |
| 12 | 20mm thick cement plaster 1:5 in two coat work (CSR 15.21) |
| 13 | Preparation of plastered surfaces for distempering including surface, applying filling with approved quality filler consisting of plaster of paris and chalk mitti including finishing the surface to the required finish complete . (CSR 16.6) |
| 14 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats on old distempered work when shade is changed CSR 16.12 |
| 15 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. CSR item 16.15 |
| 16 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.CSR 16.16 |
| 17 | Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint. CSR 16.18 |
| 18 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. CSR 16.20 |
| 19 | Painting two or more coats with aluminum paint to give an even shade excluding priming coatCSR 16.25 |
| 20 | Finishing walls with cement based water soluble exterior paint such as snowcem, robbiacem etc. two or more coats to give an even shade CSR 16.13 |
| 21 | Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt) (For shutter area up to 0.50 sqm) (CSR 17.23 (i) |
| 22 | Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc.complete : (250mm x 16mm) (CSR 17.49 b) |
| 23 | Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs completeDoors and windows frame of size 113mm x 60mm with 35 mm wide single rebate weighing 3.38 kg per meter.CSR 18.24b |
| 24 | Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position Code: IS 2202-1 (1999):(35mm thick) (CSR 17.27 a (iv) |
| 25 | Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area CSR 18.25b |
| 26 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete CSR 18.18 |
| 27 | Screed of 50mm thick cement concrete 1:8:16 with stone aggregate to be laid below the topping using mechanical mixer for mixing of material CSR 14.11 |
| 28 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) Size 600x600 mm CSR 14.115a |
| 29 | Providing a nd laying 50 mm thick fa ctory made cement concrete interlocking paver block of M-30 gra de ma chine ma de rubber moulded smooth finish with strong vibratory process or with vibro- hydra ulic compa ction ma chine a nd of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compa cted bed of coa rse sa nd, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Cha rge. IS Code: 15658 (2006) as per item 14.136 |
| 30 | 1.2 meter high G.I. barbed wire fencing with 1.8 meter angle iron posts 40x40x6mm placed every 3 meters centre to centre 0.6 meter below ground level, every 15th post, end post, corner post suitably strutted and provided with 9 horizontal lines and two diagonals interwoven with horizontal wires fixed with GI staples, turn buckles etc. including foundation concrete 1:2:4 of size 0.30x0.30x0.75m for each post complete as per technical clause 808 of MORT&H specifications) as per item 24.43 a |
| 31 | Credit Of Old Material |
| 32 | Old bricks after dismentallingof brickwork |
| 33 | Old brick bats after dismentallingof brickwork |
| 34 | Old Steel |
| 35 | Old Tiles after dismentaling |
| 36 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\" deep for walls and CI 3\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 37 | Wiring fan point (with fan box ) |
| 38 | Wiring light point |
| 39 | Wiring6 Amp. wall socket point |
| 40 | Wiring6 Amp. Plug control comprising wall socket point |
| 41 | Wiring16/20 amp. power plug control point |
| 42 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitableupto1100voltsgradeconfirmtoIS:694/1990leftbareinpipeorcasingofsuitablesize complete in all respect as desired by the Engineer-in-charge:- |
| 43 | Overall size 1.5sq.mm (Un-sheathed) |
| 44 | Overall size 4sq.mm (Un-sheathed) |
| 45 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) asperIS:4984:1995forwiringpurposesincludingbends,junctionboxes,Steelhooks,M.S.saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 46 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 47 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB\"s for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve CandlowwattlossesasperIS/IEC60898-1,energylimitationclass-3,truecontactindication,label holderfacilityintheexistingMCBdistributionboardasperPWDGeneralSpecificationsincluding connections with suitable size of thimbles/lugs:- |
| 48 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 49 | MCB Double Pole 40amp. (10kA, Curve-C) |
| 50 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB\"s:Supply and erection of sheet metal DoubleDoorDistributionBoardsIP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flushmountingwithfullyinsulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color- codedinterconnectingwireset,cable ties, blanking plates and circuit identifications label and of required no. of ways for mountingminiature circuit breakers/ RCBO\"s/ RCCB\"s in the distributionboard(ForSP&N distribution board with provision DP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings) as per PWD General specificationsincludingconnections with suitable sizeofthimbles and bonding to existing earth etc:- |
| 51 | SP&NDoubleDoorDistributionBoard8 way each |
| 52 | SupplyanderectionofLEDbatten20wattLED(includingLEDdriver)with Highqualityextruded aluminiumwith efficacy ofLEDfixture minimum100 lumensper watt and operatingvoltage between 140to270volt,inputACfrequency50Hz±3%complete alongwitherectionofthesamewith connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.ThecertificationandSpecificationsoftheLEDFitting\"sshouldbe asapprovedbyO/oAdvisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. |
| 53 | Supply and erection of Ceiling Fan 1200mm (48\") with double ball bearing including flexible wire & petty materialetc.forconnectionsandtestingcompleteinallrespectsasapprovedanddesiredbythe Engineer in-charge at site. The fan should conform to Technical Specifications attached. |
| 54 | Less the cost of Dismental Electrical Material @1% |
| 55 | Add 1% Cultural Affairs & Heritage Maintenance Cess |