| 1 | Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as irected in : |
| 2 | a) All kinds of soil |
| 3 | Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in : |
| 4 | a) All kinds of soil |
| 5 | Extra for additional depth of 1.5 m or part thereof in: |
| 6 | Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. |
| 7 | Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete. |
| 8 | b)Morrum |
| 9 | Providing & laying cement concrete 1:2:4(1 cement: 2 coarse sand: 2 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering,shuttering and finishing in: |
| 10 | a) All works upto plinth level |
| 11 | Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1cement :4 coarse sand)in foundation and basement. |
| 12 | Lateritemasonry in neatly dressed stones for 23 cms thick masonry walls in cm. 1 : 5 (1 cement : 5 coarse sand) in foundation uptoplinth level |
| 13 | Extra for laterite masonry in all sizes in superstructure from floor I level upto floor V level. |
| 14 | Centering & shuttering including Strutting, Propping & removal of forms for : |
| 15 | iii) Columns, Piers, Pillars, Aburments, Posts and struts (square rectangle polygon in plan). |
| 16 | iv) Sides and Soffits of beams, Beam Haunchings, Cantilever, Girders, Bressumers and Lintels plinth beams not exceeding 1m in depth |
| 17 | Providing and laying in position (1:11/2:3) Reinforced cement conrete excluding the cost of centering, shuttering, finishing and reinfrocement (1 cement: 1½ coarse sand:3 graded stone agg 20mm nominal size) |
| 18 | a)All works upto plinth level |
| 19 | Providing TMT steel reinforcement bars of SAIL, TATA. VIZAG made only (Confirming to IS 1786 of 1986)for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floorsalongwith the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. |
| 20 | 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge. |
| 21 | 12mm cement plaster 1:4 (1 cement : 4 fine sand) |
| 22 | Providing & fixing G.I. pipes complete with G.I. fittings including trenching & re-filling etc. (external work). |
| 23 | g)80 mm nominal bore |
| 24 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 /Rectangular Hollow Section (RHS) IS4923/ Circular Hollow Section (CHS) IS1161 closed Structural Steel of (SAIL, TATA. VIZAG, JSW ,APOLLO Steel Ltd.) make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 25 | Providing and fixing M.S. grill of required pattern in wooden frames of Windows etc. with M.S. flats square or round bars with round headed bolts and nuts or by by screws |
| 26 | a)Plain Grills |
| 27 | Providing and fixing colour coated galvulium roofing sheets of 0.5mm thickness including all the accessories (TATA make) but excluding the cost of purlins, rafters, trusses, flashings etc. complete as per the directions of the Engineer in chargeflashings etc. complete as per the directions of the Engineer in charge.e Add for providing & fixing Flashings -[Corners, Ridges, valleys, gable end & Trims] (Girth above 610mm) including all the accessories complete as per the directions of the Engineer in charge. |
| 28 | Providing and fixing coloured ceramic tiles spartek or equivalent of 8\" x 8\" size and 6 mm thick in skirting and dados on 12 thick cement plaster 1:3 (1 cement : 3 coarse sand) and jointed with cement slurry complet |
| 29 | Single Colour Foam Core FRP (Fiber Reinforced Polymer) Door Shutter Manufacture, Supply and Installation (including accessories as mentioned below) of EPEE or equivalent Goan make FRP (Fiber Reinforced Polymer) door shutter of specified thickness as per options below by using tray system with seasoned hard wood, moisture less than 17%, wood styles for Top rail and lock rails. FRP (Fiber Reinforced Polymer) laminate made up of 450 grams per sq.mts (gsm) chop strand matt and unsaturated polyester resin with viscosity range of 400/450 centipoises per second (cps) . The core of shutter will be filled as specified (Expanded Polystyrene Foam / Polyurethane Foam (EPS/PU) Foam). The shutter to be of single colour & water proof as well as mild acid / alkali resistant manufactured using RV TIFAC (R V Engineering College, Bangalore & Technology Information Forecasting & Assessment Council) technology in line with IS 13034 1990 test Standard in an ISO 9001 – 2015 certified factory. 103 Accessories: i i) S. S. Hinges 4” - 3 Nos ii ii) S. S. Latch - 1 No iii iii) Tower Bolt 5” - 2 Nos iv iv) Handle 5” - 2 Nos Shutter Thickness : a) 30mmb) 35mm c) 40mm |
| 30 | Door |
| 31 | FRP (Fiber Reinforced Polymer) Frames Manufacture, Supply and Installation (with anchor fastener) of EPEE or equivalent Goan make FRP (Fiber Reinforced Polymer) Frame of cross section as per options below with right angle joint and FRP (Fiber Reinforced Polymer) laminate made from 450 grams per sq.mts (gsm) chop strand glass fiber (matt) and unsaturated polyester resin with viscosity range of 400/450 centipoises per second (cps). The core of frame would be filled with seasoned wood as infill material. The slot of frame for door resting will be of suitable width so as to take specified thickness door.. The frame will be water proof as well as mild acid/ alkali resistant manufactured in an ISO 9001- 2015 certified company. Specified Cross Section : a) 3” x 2”b) 4” x 2” c) 4” x 2 ½ “d) 5” x 2 ½ |
| 32 | b) 4” x 2” |
| 33 | Supplying and fixing rolling shutters of approved make, made of 80 x 1.25 mm M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No.2 and M.S. top cover of 1.25mm thick for folling shutterstop cover and spring |
| 34 | Applying one coat of distemper primer of approved brand and manufacture on wall surface. |
| 35 | Painting three or more coats with acryllic exterior paint of approved brand and manufacture (Such as Dulex/ Asian Paints/ Sherwin Willians) including applying one coat of cement primer and one coat of surface treatment etc. complete |
| 36 | Painting two or more coats (excluding priming coat) with superior quality ready mixed paint for steel work of approved brand & manufacture in all shades on new work to give an even shade |
| 37 | Constructing brick masonry manhole or inspection chamber with second class bricks in cement mortar 1:5 (1 cement :5 fine sand) R.C.C. top slab with 1:2:4 mix (1 cement: 2 coarse sand ;4 graded stone aggregate 20mm nominal size foundation concrete 1:2:4 mix (1 cement ;2 coarse sand :4 graded stone agrregate 40mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cemetn and making channels in cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) neatly finished complete as per standard design. |
| 38 | d)Inside size 60 x 60cmand 60cm deep including C.I. cover with frame (light duty) 455x610mm internal diameter total weight of cover and frame to be not less than 38 kg. (weight of cover 23 kg). |
| 39 | Constructing soak pit 1.20m x 1.20m x1.20m filled with laterite stone aggregate 125 to 180 mm including S.W. drain pipe 100 mm diameter and 1.2m. long complete as per standard design |
| 40 | Proving and fixing white vitreous china water closet squatting pan (Indian type w.c. pan) size 580 mm with 100 mmsand cast iron P. or S trap 10 litres high level P.V.C. flushing cister (of approved make) with fittings, rack bolts 32 mm diameter P.V.C telescopic flush pipe with fit tings and clamps 25mm P.V.C. over flow pipe withspecials & mosquito proof coupling of approved municipal design and nylon pull complete cutting and making good the walls and floors where required. |
| 41 | a) Long pan pattern W. C. Pan |
| 42 | Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes of approved including lubricant etc. complete (single/double) socketed: |
| 43 | Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes ofapproved including lubricant etc. complete (single/double) socketed: |
| 44 | a) 110 mm dia |
| 45 | b) 75 mm dia |
| 46 | Providing and fixing anodized aluminium shutters in accordance with the specification annexed with Goa schedule of Rates (2004) Vol & II including all taxes, transportation, scaffolding and handling etc. complete as per direction of the Engineer-in-charge: Single or double leaf door shutters. a |
| 47 | a)Acrylic sheet |
| 48 | Providing and fixing anodized aluminium shutters in accordance with the specification annexed with Goa schedule of Rates (2004) Vol & II including all taxes, transportation, scaffolding and handling etc. complete as per direction of the Engineer-in-charge: windows with two sliding shutters using 18 mm series shutters section. |
| 49 | c) Figured glass |
| 50 | Cuddappah stone slab machine cut flooring over 20mm (average) thickness of cement mortar 1:4 (1 cement : 4 coarse sand laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete - 25 mm thick. |
| 51 | Steel work(SAIL, TATA. VIZAG only) riveted or bolted in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of red lea |
| 52 | b)In tees, angles, flats and channels |
| 53 | Supplying and fixing 3mm thick acrylic sheet with putty nails, in door/ window shutters including removal of broken glass pane wherever necessary. |