Tender For Construction Of Tensile Parking Shed, Washing Platform Shed, Boom Barrier, Water Proofing Treatment Of Office Area And Other Work At Old Rdc And Sdo Residence Mayors Road, Ranchi For The Year 2022-2023, ranchi-Jharkhand

Building Construction Department-BCD has published Tender For Construction Of Tensile Parking Shed, Washing Platform Shed, Boom Barrier, Water Proofing Treatment Of Office Area And Other Work At Old Rdc And Sdo Residence Mayors Road, Ranchi For The Year 2022-2023. Submission Date for this Tender is 20-02-2023. Barriers Tenders in ranchi Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

36247460
Tender For Construction Of Tensile Parking Shed, Washing Platform Shed, Boom Barrier, Water Proofing Treatment Of Office Area And Other Work At Old Rdc And Sdo Residence Mayors Road, Ranchi For The Year 2022-2023
Open Tender
Indian
Jharkhand
ranchi
20-02-2023

Tender Details

Construction Of Tensile Parking Shed, Washing Platform Shed, Boom Barrier, Water Proofing Treatment Of Office Area And Other Work At Old Rdc And Sdo Residence Mayors Road, Ranchi For The Year 2022-2023

Key Value

Document Fees
INR 10000 /-
EMD
INR 179100.0 /-
Tender Value
INR 89.50 Lakhs /-

BOQ Items

Name of Work:Construction ofTensile Parking Shed, Washing Platform Shed, Boom Barrier, Water Proofing Treatment of Office Area and Other Work at OLD RDC & SDO Residence Mayor"s Road, Ranchi for the year 2022-2023
Sl. No. Item Description
1Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil itemA) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.
2Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B)
3Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
4Providing designation 75B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
5Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
6Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
7providing Tor steel reinforcement of 10mm,12mm,16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I.
88mm dia (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}
9(a) 10mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}
10(b) 12mm &16mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)})
11Centering and shuttering including strutting, propping etc. and removal of form forFoundations, footings, bases of columns, etc. for mass concrete
12Filling in foundation trenches and plinth in layers. Not exceeding 150 mm thick well watered, rammed fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
13Steel work in built up tubular ( round, square or rectangular hollow tubesetc.) trusses etc., including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primer, including welding andbolted with special shaped washers etc. completeHot finished welded type tubes
14Providing corrugated G.S. sheet roofing including vertical / curved surfacefixed with polymer coated J or L hooks, bolts and nuts 8 mm diameterwith bitumen and G.I. limpet washers or with G.I. limpet washers filledwith white lead, including a coat of approved steel primer and two coatsof approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, raftersand trusses and including cutting to size and shape wherever required. 0.80 mm thick with zinc coating not less than 275 gm/ m²
15Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
16Providing and laying 60mm thick factorymade cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibration including all complete job as per direction of E/I.
17Providig and fixingpanic bar/latch(Doublepoint) fitted with a single body,Trim Latch & Lock on back side of the paic latch of rreputed brad and manufacture to be approved by the E/I.
18Providing designation 75 B brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
19Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
20Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
21Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
22Providing and Fixing factory made uPVC white coloursliding glzed windowThree track three panels sliding window made of (big series) frame 92x44mm &sash 32x60mm both having wall thickness of 1.9±0.2mmand single galzed bead /double glazing bead of appropriate dimension(Area of window above 1.75sqmm upto 2.50sqm)weather proof siliconsealelnt over backer rod of required size and of approved quality,all completeas per approved drawing & direction of E/I.(single/double galss panes,wire mesh and silicon sealant shall be lpaid separately) Note_For UPVC frame and sash extruded profiles minus 5% tolerance indimension i.e.indepth & width of profile shall be acceptable.Three track three panels sliding windows with fly proof S.S.wire mesh( two nos,glazed & one no wire mesh panels ) made of (big series) frame 116x45mm& sash 46x62mm both having wall thickness of2.3±0.2mm and single glazing bead/double glazing bead of appropriate dimension.(area of window above 1.75sqm)
23Providing & fixing glass paanes with putty and glazing clips in steel doors,windows,clerestory windows,all complete job as per direction of E/I. 5.50mm thick glass panes.
24Providing & fixing fly proof wire gauze to windows, clerestory windows &doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and1.4 mm aperture on both sides
25Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanicallywherever required including cleat angle, Aluminium snap beading forglazing / paneling, C.P. brass / stainless steel screws, all complete as perarchitectural drawings and the directions of Engineer-in-charge. (Glazing,paneling and dash fasteners to be paid for separately) :Powder coated aluminium (minimum thickness of powdercoating 50 micron
26For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Polyester powder coated aluminium (minimum thickness of polyesster powder coating50 micron)
27Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness
28Providing precast cement concrete Jali 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 6mm nominal size ), reinforced with 1.6 mm dia mild steel wire, including centering and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete, excluding plastering of the jambs, sills and soffits.
2950 mm thick
30Dismantling aluminium/Gypsum partitons,doors,windos,fixed glazing and false ceiling including disposal of unserviceable surplus materials and stacking of serviceable materials within in 50 meters lead as directed by E/I.
31Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at230 mm c/c, including jointing and finishing to a flush finish of tapered andsquare edges of the board with recommended jointing compound , jointingapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with12.5 mm thick tapered edge gypsum moisture resistant board
32Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I.
33Supplying materials and labours for constructing inspection chamber of designation class 75 B bricks size 750 mm deep, 600 x 450 internal dimension having 250 mm wall thickness in cement mortar ( 1:6 ) including 12 mm cement plaster ( 1:4 ) with punning on inside and cement plaster (1:6 ) with 600 x 475 mm G.I. cover with frame (Weight not less than 36 Kg.) in foundation andrefilling all complete as per specification and direction of E/l.
34Supply of Recess Mounting LED Round light Down light 15/16W approved quality including all complete job.
35Supplying and fixig 560mm diameter C.I.cover (heavy duty) the weight of the cover to be not less than 108 kgincludig all complete job.
3615W COB based round LED light with multiple beam angles(36 Degree)
37Supply Installation,testing and commissioning of follwing size ceiling fan 3 Bleades confirming to IS:374:2019 including wiring the down rods of standard length(upto 30cm) with 1.5 sqmm FR PVC insulated ,copper wire suitable for 230V 50Hz,single phase supply etc.complete as required.
381400mm(56")BI DC 5 star rating 32W ceiling Fan
39Providing Fitting Fixing of HPL pannel with all necessary materials all complete job as per building specification and direction of E/I.
40Carriage of materials from nearest approved sources of supply including loading into trucks and unloading from trucks and stacking properly at work site as directed by the E/I.
41Brick lead 8K.M(1K+7P)
42sand lead 8K.M.
43S/F/F of Secureye Automatic Boom Barrier upto 6 meter Alluminium boom including Electrical works all complete job.
44Structural Steel Work: Providing, Fabricating, Assembling, painting, hoisting, erecting and placing in position MS Built-up section/Tubular Structure (MS built-up section:-Rolled section & plates confirming to 15 2062 minimum required grade E240, Tubular Structure made from Steel hollow sections from APOLLO/ JINDAL/BHUSHAN/ISI marked & evuivalent, conforming to I5 1161/4923, minimum required Grade YST 240, in the profile shape as per drawings with special plate connector, pinion joints, Plates, hollow sections etc. using flame cutting system, SAW/MMAW/MIG welding process with special plate connectors, pinion joints, plates, hollow sections to all heights, tools and plants and 1 necessary scaffoldings etc. required for all operations involved. The structural members shall be painted with 60 DFT anticorrosive protection coating using Paint/Primer of approved make (ASIAN/MRF/BERGER/NEROLAC/JUTON & Equivalent) with one or two coat of Epoxy Primer cum MIO 60 microns thick and final coat of polyurethane paint 60 microns thick (to be applied in 2 coats). The item shall be executed as per approved drawings and direction of the Engineer-in-Charge complete.
45Tensile Membrane Fabric: Tensile Membrane Fabric Providing, fabricating, assembling and erection of pre stressed Tensile Membrane Fabric structure in desired profile as per drawing, with Nanopolymered Fluorinated Lacquer system on both sides, Type I Mehatop N or Versidige fabric having a minimum weight of 700 g/sqm, HT polyster yarns count 1100 dtex, minimum thickness 0.6 mm, minimum tensile strength 3000 N/5cm in wrap and 3000 N/Scm in weft directions, minimum tear strength 300 N in wrap and 300 N in weft, as per particular specification with a 15 years warranty from manufacturer etc. over steel frames with all fittings and fixtures such as Galvanised MS Membrane / End Plate, Shackles, Rigging Screws, Turnbuckles, swedge, fork, keder rods & galvanized MS strands Cables with stainless steel end terminals complete as per Drawing/Detail & as per technical specifications and as per the instructions of Engineer-in-charge. (Rate includes cost of fabric, shop drawings, patterning, forming, cutting, fabrication, hot weld stich of fabric, Transport to the site, assembling and installation with GI cables, hardware, Alluminium flat, EPDM gasket and required accessories wherever required complete including lifts upto all heights, tools and plants, and necessary scaffolding etc. required for all operations in all respect for fixing the fabric as approved shape as per drawing and direction of Engineer-In-Charge).(Note: Actual Surface area of fabric shall only be measured for payment.)
46S/F/F of 50 Watt LED vapour spot light With Wiring make Phillips all complete job.
47S/F/F of Morvi Tiles(Size 1"6"x10") on Roof all complete job.
48Preparing and rectifying the existing Coving (Hallar) along the gap between roof slab and slope roof resting :Preparing and rectifying coving with polymer modified mortor admixed with 10% of SBR latex in ratio 1;3 .Apply fisrt coat of Modified cementituos coating overthe prepared coving . Install 3 ply Expandable Pronil tape dipped with Waterrepellent primer over the Modified cementituous coating of Fibre fex XL .Apply second coat of Modified Cementituous coating of Fibre flex XL . Micro concrete : Install Microconcrete MC 40 (Free flow non shrinkage general purpose Cemetitious Micro Concrete ) wall of 250 mm height 75 mm thick attachedto Coving by Anchoring steel with resin grout along the length of Coving which will act as guard wall to protect water ingress through Coving . Junction of GI sheet and paraphet wall : Removing the existing mortor at the pheriphery of Junction and apply Epoxy Bonding agent over the GI sheets and Curve of the GI sheet insertion to Pharaphet wall and fill the gap with LaGafill after application of epoxy bonding agent admixed with SBR latex @ 10% by the weight of Gap fill. Same is repeated for filling up pipes gap joints and Clay Tiles.
49Supply fittings and fixing basketball pole with fiber body board and synthetic hoop.( 3mtr height, make proIndia/ Nevia)
50Supplying Fitting & fixing Morbi tilesincluding all complete job as per direction of E/I.
51Providing Fitting Fixing of Mosquoto Mesh Frame and all Fittings (Make-Insect Shield) all complete job as per building specification and direction of E/I.
52Providing Fitting Fixing of S.S Railing 304 Grade Square Pillar and R.B Filling all complete job as per building specification and direction of E
53Providing Fitting Fixing of S.S Partition with reinforced steel 304 Grade pipe with Fiber Sheet all complete job as per building specification and direction of E/I.
54Providing Fitting Fixing of S.S Grill with all Materials steel 304 Grade pipe with all complete job as per building specification and direction of E/I.
55Making Modular Design Hanger Stand Made on S.S 304 Grade with all Materials all complete job as per building specification and direction of E/I.
56Providing Fitting Fixing of S.S Partition Made on 304 Grade Square tube 40x40 Square Tube as per Drawing given with SS Rinforced with fiber sheet all complete job as per building specification and direction of E/I.
57Add 18 % GST (in Basic Rate must fill 12)
58Add 1% Labour Cess (in Basic Rate must fill 1)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail