| 1 | Removal of Existing all kinds of roof sheets, ridges and damaged purlins manually/ by mechanical means above 5m height including stacking of serviceable material and disposal of unserviceable material out side HSL Premises as per direction of Engineer-in-charge etc., complete |
| 2 | Supply and fixing of pre coated, Trapezoidal profiled Galvalume Roofing sheets(Size,shape and pitch of corrugation as approved by Engineer-in-charge) with total coated thickness (TCT) of 0.50mm above 5m height. Zinc Aluminium alloy coating AZ 150 as per IS27/ASTM 1379 in 550Mpa steel grade, painted with Silicon Modified Polyster 18-22 microns on top 5-8 microns Eproxy primer at bottom side of the sheet from Jindal / Bushan Steel . The sheet shall be fixed using self drilling / self tapping screws of size 5.5mmX55mm @500mm c/c along the length of the purlins and wherever specifiedby engineer with EPDM seal of make CORRO SHIELD/ BUILTEX/ HILTI. (Quoted rate shall inclusive of end and side laps of sheet, tape, sealer, closures and closing of gap between roof sheet and existing walls with CM 1:4 both inside & outside) allComplete as directed by Engineer In charge. |
| 3 | Supply, fabrication and erection of Structural steel for making purlins using MS tube sections, angles, etc (at 5m above Ground level) fixed to existing wooden/ steel trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete all complete all as directed by Engineer In charge. |
| 4 | Fabrication and erection of structural steel for making support structures of OH tanks using HSL supplied material including loading, transporting & unloading of supplied material, required consumables, tools and machineries all complete as directed by Engineer In charge. |
| 5 | Clearing of jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level, removal of rubbish including disposal of all debris outside HSL premises as directed by Engineer In charge. |
| 6 | Providing Two(2) coats of white washing with suryacem / Hitech gold to walls and ceiling surfaces after through scrapping, sand papering and cleaning the surface to give even shade etc., complete all as directed. |
| 7 | Providing two(2) coats of synthetic enamel paint for doors, windows, grills, rolling shutters, Purlins etc., of required colour using approved branded paints like Asian / Berger after removal of rust using wire brush or sand paper to give an even shade on old work including applying one coat of required primercomplete all as directed |
| 8 | Supply and Fixing of wind ties with MS flat of required size including necessary bolts and nuts at 1m c/c spacing specified by Engineer representative fixing to the existing purlins complete all as directed by the Engineer incharge. Quoted rate shall be inclusive of one coat of priming coat, consumables like bolts, nuts, washers, etc., |
| 9 | Making and Fixing of wooden purlins / door frames / window frames using HSL supplied wood. loading, trasporting and unloading of supplied material, arranging necessary scaffolding etc.,are in scope of contractor. all complete as directed by Engineer In charge. |
| 10 | Providing 12 mm thick plaster with CM (1:4) to walls at all heights and ceilings, beams, Stair-case, lintel soffits, chajjas, projections, narrow bands and widths etc., including cost of all materials, tools, plant and labour, scaffolding arrangements and curing all as per specifications and directions of the engineer. |
| 11 | Providing and fixing 1st quality anti-skid floor tiles& ceramic wall tiles of size 300x600mm(Concept tiles) in toilets & wash rooms of 10mm thickconforming to IS : 15622,of approved make SOMANI / KAJARIA in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including pointing the joints with white cement and matching pigments etc., Quoted rate shall be including cost ofCement (PPC-Ramco, ACC, Ultratech, Nagarjuna, Birla Gold & Jaypee) & all materials complete all as directed. (Rate includes chipping of existing floor & wall tiles/Cement dadoos) |
| 12 | Demolishing of RR/brick masonry work in Cement mortar by manually / mechanical means including stacking of serviceable material and disposal of unserviceable material outside HSL premises as per direction of Engineer-in-charge. |
| 13 | Construction of Brick work with common burnt clay F.P.S (Non-Modular) bricks of class designation 7.5 in superstructure above plinth level upto floor V level in all shapes and sizes in cement mortar 1:6 (1 Cement : 6 coarse sand) including cost of cement (PPC - Ramco) and all materials etc., all complete as directed by Engineer In charge. |
| 14 | Removal of MS Rolling shutters along with the frames, supports, covers, all fittings and disposing the same to designated location inside HSL yard as directed by Engineer In charge. |
| 15 | Providing plain cement concrete 1:2:4 of nominal mix using 20 mm graded crushed granite aggregate including mixing, depositing in position, tampering, finishing, curing including all materials & labour etc., complete all as directed. |
| 16 | Removal of old damaged wooden partitions, door/window shutters with frame, handing of serviceable materials to CE department and disposal of unserviceable materials outside HSL premises as directed by Engineer In charge |
| 17 | Supply and fix 32mm thick, skelton joinery for Windows shutters with panneled wood (including removal of old damaged shutters etc., and handing over useful material to CE dept.,) by using kamba wood complete all as directed. |
| 18 | Providing and fixing 30 mm thick ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, solid core of block board construction without frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters (including polishing) ISI marked Stainless Steel butt hinges with necessary screws and connected anodised aluminium hardware materials like aldrop & tower bolts, door stopers etc., Complete |
| 19 | Supply & Fixing Brass PVC bib cocks (long body) of make Watertec or tis equivalent etc., Complete all as directed. |
| 20 | Supply & provide 100 mm diafloor trapalong withStainless steelgratingof approved quality etc., complete |
| 21 | Supply of 110 mm dia UPVC(SWR) rain water downtake pipes conforming to IS : 13592 Type A, jointing with seal ring conforming to IS : 5382, including fixing of clamps, bends, shoes (supreme/ prince make) and removing of old pipe line and handover to disposal section etc., complete |
| 22 | Providing and fixing 15 mm nominal dia CPVC pipes for plumbing lines of approved make Supreme / Prince / Astrial including fittings and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 23 | Providing and fixing 25 mm nominal dia CPVC pipes for plumbing lines of approved make Supreme / Prince / Astrial including fittings and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 24 | Providing and fixing 32 mm nominal dia CPVC pipes for plumbing lines of approved make Supreme / Prince / Astrial including fittings and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. |
| 25 | Supply and fixing of triple layered PVC OH water tank of 1000Ltr capacity of make sintex /Reno including necessary fittings etc as directed by Engineer In charge. |
| 26 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink of size 610X510 mm bowl depth 200mm as per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required etc., complete (Nirali / Anjali / Parryware make) |
| 27 | Supply and fixing of 25 mm thick 750 x 2000 mm size, PVC doors with frame & shutter for toilets (Hitech or equvilant make) including aluminium aldrop, towerbolt, handles and butt hinges etc., complete |
| 28 | Providing and fixing white vitreous china flat back lipped front urinal basin of 430x260x350 mm with G.I clamps, 32mm dia PVC waste pipe, 15mm dia PVC polythene connector including fittings and brackets, cutting and making good the walls and floors wherever required etc., complete (parryware/ hindiware) |
| 29 | Providing and fixing white vitreous china urinal partition of required size with G.I clamps including fittings and brackets, cutting and making good the walls and floors wherever required etc., complete (parryware/ hindiware) |
| 30 | Supply, fit and fix white glazed earthenware European type water closest of Parryware / Hindware / Jaquar make with \"P\" or \"S\" trap with or without vent hole, colour or black solid plastic seat and cover with low level cistern of 10 litres capacity of same make as specified including all fittings, materials, tools and labour etc., complete. |
| 31 | Providing PVC health faucet including 1.5m flexible pipe of make Watertec or its equivalent including all accessories etc., complete |
| 32 | Providing and fixing PTMT soap Dish Holder of approved make Watertec or its equivalent having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms etc., complete |
| 33 | Providing and fixing CP Towel rail of standard length of approved make Waterteck or its equivalent including all accessories etc., complete |
| 34 | Supply & Fixing 15 mm dia bore Brass C.P angle cocks of standrad quality with 15mm dia bore and Complete all as directed. (Watertec or its equivalent) |
| 35 | Supply & Fixing 15 mm dia bore CPbrass stop cocks of standrad quality with 15mm dia bore of approved makeconfirming to IS:8931 and Complete all as directed. (Watertec or its equivalent) |
| 36 | Supply of 75 mm dia UPVC (SWR) Soil and waste pipes conforming to IS : 13592 Type B, jointing with seal ring conforming to IS : 5382, including fixing of clamps, bends, shoes (supreme/ prince make) complete |
| 37 | Cleaning of drain and disposal of debris outside HSL premises as directed by Engineer-in-charge |
| 38 | Providing 40x3mm flat iron hold fasts 250mm long including fixing to doors and window frames with 10mm dia 65mm long tail screws and wooden plugs and embeded in cement concrete block 300mmx100mmx100mm of 1:3:6 mix using graded granite aggregate of 20mm nominal complete all as directed. |
| 39 | Provide and fix Stainless steel butt hinges of 100x70x4 mm with necessary SS screws and other necessary fittings. |
| 40 | Provide and fix Stainless steel tower bolts (barrel type) of size 150x10 mm with necessary fittings for doors. |
| 41 | Provide and fix brass aldrops for doors of 300 mm long 16 mm diawith necessary fittings. |
| 42 | Providing and fixing aluminium hanging floor twin rubber door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete |
| 43 | Providing and fixing aluminium anodised peg stays for windows (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete |
| 44 | Providing and fixing 1st quality Netlon or its equivalent Mosquito fly proof mesh to windows and Ventilators including necessary wooden beading and also 2 coats of enamel paint/ sticker type etc., Complete all as directed. |
| 45 | Felling trees of the girth upto 60cm (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material all as directed by Engineer In charge |
| 46 | Cutting branches of trees upto 600 mm girth and disposal of unserviceable material out side the HSL premises. |
| 47 | Disposal of debries, surplus earth, wooden scrap, garbage and rubbish outside the HSL premises toprivate dumping yard up to 20Km lead (not to dump in HSL colony dumping area & surrounding areas) it is the responsibility of the firm to ensure no objection shall be raised by Muncipal authorities / from any body. If any dispute arises the agency has to sort out at their own risk etc., complete all as directed. |
| 48 | Repairaing and Refixing of wooden window shutters/Wooden door shutters with required materials and hardware fittings. (Hardware fittings will be measured seperately) |
| 49 | Supply, fix, test and commissioning of 3 phase, VTPN 4 way double door MCBDB with 40 Amps, 4 pole MCCB/Isolator as main incomer and 10 A to 32 A, 10KA SP/DP MCBs as outgoings including all accessories as required and as directed. Approved make Schneider/ Siemens/ ABB / Havells or Equivalent make as approved by Engineer in-charge. |
| 50 | PVC conduit wiring with 3 runs of 1.5 sq.mm FRLSH PVC flexible copper cable for One point controlled by one switch as directed (It includes finishing with CM 1:5 and surface to match with the existing surface). |
| 51 | PVC conduit wiring with 3 runs of 1.5 sq.mm FRLSH PVC flexible copper cable for Two point controlled by one switch as directed (It includes finishing with CM 1:5 and surface to match with the existing surface). |
| 52 | PVC conduit wiring with 3 runs of 2.5 sq.mm FRLSH PVC flexible copper cable for switch sockets as directed (It includes finishing with CM 1:5 and surface to match with the existing surface). |
| 53 | PVC conduit wiring with 3 runs of 4 sq.mm FRLSH PVC flexible copper cable for AC units, Oven and Refrigerators as directed (It includes finishing with CM 1:5 and surface to match with the existing surface). |
| 54 | Supply, fix, test & commissioning of 3 modular type switch board with 01no. 16A (3+2 pin) modular socket and switch. |
| 55 | Supply, fix, test & commissioning of 3 modular type switch board with 01no. 6A (3+2 pin) modular socket and switch. |
| 56 | Supply, fix, test & commissioning of 12 modular type switch board with 5A 3-pin modular sockets & switches, fan regulator as directed by engineer in-charge. |
| 57 | Supply, fix, test & commissioning of 8 modular type switch board with 03nos. 3pin 5A modular socket with 2nos. switches as directed by engineer in-charge.. |
| 58 | Supply, fix, test & commissioning of 4 modular type switch board with 04 nos. 5A modular switches & fan regulator as directed by engineer in-charge. |
| 59 | Supply, fix, test & Commissioning of 20A DP MCB DB with Metalic Enlcosure for AC units as directed by engineer in-charge. |
| 60 | Supply, fix, test & commissioning of 20W LED Tube light as directed by engineer-incharge. |
| 61 | Supply, fix, test & commissioning of 1phase, 240V, 1200 mm 5 star rated Ceiling Fan as directed by engineer in-charge. |
| 62 | Supply, fix, test & commissioning of 1phase, 240V, 300 mm sweep exhaust fan with louvers as directed by engineer in-charge. |
| 63 | Removal of all existing wiring material, Switch Boards, fittings, cables, electrical panels, equipment etc. and handover to Plant Maintenance Dept. |