Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 28-02-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 07-03-2023 |
| 2 | 14-02-2023 | MAKES CORRIGENDUM | Other | 28-02-2023 |
| Sl. No. | Item Description |
| 1 | Taking down carefully ceiling fan, exhaust fan, wall / pedestal fan of any make and any sweep and dismantling of blades, canopy, down rod etc & remove to store for repair & refixing the same including provision of 3 core 0.5 sq mm copper flexible cable from ceiling rose to connector.Note(i) The representative of the contrcator shall report to Engineer-in-charge/JE on daily basis to carry out repairs to fan and the defects should be rectified on the same day |
| 2 | M&L for Opening of cleaning of slots, Rewinding of fan by super enameled copper insulated wire as per existing gauge, varnishing, heating assembling and testing complete all as directed by Engineer-in-Charge. Note - Spares such as Bearing, Capacitor, Capacitor Clamp, Rubber insulator will be measured seperately under respective item of this schedule |
| 3 | Ceiling fan 1200 / 1400 mm Sweep. |
| 4 | Exhaust Fan,Pedestal fan,wall fan, table fan 300/400 mm Sweep. |
| 5 | Exhaust Fan, Pedastal fan,wall fan,450/600 mm Sweep. |
| 6 | M & L for painting onlyof ceiling fan,exhaust fan,wall fan,pedestal fan for any size and type, scraping out of old paint, filling of cavities with filler, preparationof body and cleaning of dust etc Painting by Spray with first Quality Paint including over coatofzinc primer, including writing theMES number complete for allas directed |
| 7 | Overhauling of Ceiling Fan, Exhaust Fan, Wall Fan,Table fan,Pedestal Fan any Make & any Sweep including dismantling/opening of body, cleaning of body, oiling, greasing & reassembling complete, replacing of split pin, nut , bolts etc and testing Note : Spares shall be measured & paid in respective items of this sch. |
| 8 | Supply only spare parts to be incorporated for repairing fans in respective item of this schedule |
| 9 | Capacitor up to 2.5 Mfd MAKE KELTRON,EPCOS |
| 10 | Capacitor 3.15/ 4 MFDMAKE KELTRON,EPCOS |
| 11 | Capacitor Clamp of all sizes with Connector As Par Sample |
| 12 | Rubber Insulator sutiablefor any type ofCeiling Fan. |
| 13 | Mild steel Down Rod 600 mm Long with Clamp nut bolts & split pin as par sample |
| 14 | Mild steel Down Rod with Clamp nut bolts& split pin for 900 mm Long as par sample |
| 15 | Exhaust Fan bracket with frame Nut, Bolt, Rubbers etc mplete 300 mm sweepas par sample |
| 16 | Exhaust Fan bracket with frame Nut, Bolt, Rubbers etc complete 380/ 450 mm sweep as per sample |
| 17 | Ball bearing sutiable for any type of fans Make : SKF,TATA,NBC |
| 18 | Mild steel shaft as per sample for any fan |
| 19 | Ceiling Fan Blade suitable for 1200/1400 mm sweep as per sample. |
| 20 | Exhaust Fan Blade suitable for 300 mm sweep as per sample. |
| 21 | Exhaust Fan Blade suitable for 450 mm sweep as per sample. |
| 22 | Pedestal/WallFan Blade suitable for 450 mm sweep as per sample. |
| 23 | Pedestal / Wall Fan Blade suitable for 600 mm sweep as per sample. |
| 24 | Supply & Fix Exhaust fan louvers with shutter made of aluminium sheet of 0.5 mm thickness, and frames made out of mild steel, making good the distrubed surfaces in CM 1:4,including scaffolding if any required to carry out the work in building of height up to 32 Meters complete in all respects. |
| 25 | Deployment of Technician for checking fan, Fan Servicing / Safety Hook/ Pin including fixing of safety pin, nut, bolt etc. complete and entry in register duly signed by User/ Occupants.Technician will Carry scheduled preventative maintenance checks as per details to be given by Site Executive. |
| 26 | M & L for Opening switch board mounting plate at height upto 1.5m and replacing of old unserviceable piano switch 5 Amps & refixing switch plate and testing complete all as directed.Note (i) The representative of the contrcator shall report to Engineer-in-charge/JE and carry out repairs on daily basis be rectified on the same day Make - Anchor, Leader, Plaza |
| 27 | M & L for Opening switch board mounting plate at height upto 1.5m and replacing of old unserviceable fan regulator & refixing switch plate and testing complete all as directed.Note (i) The representative of the contractor shall report to Engineer-in-charge/JE and carry out repairs on daily basis be rectified on the same day Make - Anchor, Leader, Plaza |
| 28 | S&F,in repair PVC laminated ISI marked top cover 3 mm including cutting/drilling holes for mounting housing of switches, sockets, etc as per site requirement suitable for following sizes of sunken/TW board.4”x4” size |
| 29 | All as per Item No 10.00 here-in-before but 7”x4” size |
| 30 | All as per Item No 10.00 here-in-before but 8”x6” size |
| 31 | All as per Item No 10.00 here-in-before but 8”x10” size |
| 32 | All as per Item No 10.00 here-in-before but 10”x12” size |
| 33 | M & L taking down from positionexisting defective storage water heater 25 to 50 ltr Capacityfor carrying outrepairs work such as replacing worn out parts and fixing back in position in replacing the necessary nuts and bolts including disconnecting & reconnecting water & electric supply lines, testing, painting with two coats of white synthetic enameled paint by spray paint with spray gun complete all as specified and directed |
| 34 | Supply only safety valve for geyser chromium plated brass 15 mm dia all as specified and directed Make :- Racold/ Bajaj |
| 35 | Supply only non return valvechromium plated brass 15 mm dia heavy-duty all as specified and directedMake :- Racold/ Bajaj |
| 36 | Supply only indicator lamp for geyser red/green, round/square/rectangle as per site requirement 230 V AC all as specified and directed Make :- Mimic / AE |
| 37 | Supply only heating element 1500 watt threaded or push type as per the existing one suitable for vertical storage water heater of any size all as specified and directed Make :- Racold/ Bajaj |
| 38 | Supply only heating element 2000 watt threaded or push type as per the existing one suitable for vertical storage water heater all as specified and directed Make :- Racold/ Bajaj |
| 39 | Supply only thermostat suitable for storage water heaters 25to 50 Ltrs capacity adjustabletype i.e.. 0 degree centigrade to 80 degree centigrade all as specified and directed Make :- Racold/ Bajaj |
| 40 | Supply and fix only plug top 3 pin 5 Amps capacityMake: Anchor ISI/LeaderISI/RIDER ISI |
| 41 | Supply and fix only plug top 3 pin 15/16 Amps capacityMake: Anchor ISI/LeaderISI/RIDER ISI |
| 42 | Supply and fix in repairs cable flexible 3 core PVC insulated and pvc sheathed with multi stranded copper conductor size of 0.75 sqmm 1100 volts grade all as specified and directed. |
| 43 | Supply and fix in replacement of copper water tank of 25 Ltrs capacity with and including necessary gasket packing, nuts, bolts, etc completeall as directed by Engr-in-Charge. |
| 44 | Fabricating, supply and fixingin replacement geyser bottom cover duly painted in two halves suitable for vertical type storage water 25/50 Ltrs capacity forgeysers of any make as per the existing oneall as specified and directed |
| 45 | Supply & Fix in replacement flexible 15 mm dia PVC pipe for cold water of geyser with PTMT nuts on both ends of length 450mm with two washers, all as specified and directed |
| 46 | Supply & Fix in replacement flexible 15 mm dia PVC pipe for hot water of geyser with PTMT nuts on both ends of length 450mm with two washers, all as specified and directed |
| 47 | Supply and fixing in repairsSheet Metal enclosure with 2 pin and earth plug and socket complete with one single pole MCB SP of Capacity upto 20 Amps 240 Volts complete all as specified and directed |
| 48 | Taking down old unserviceable High bay, Mid Bay, Flame Proof light fittings from walls/Builings/Sheds/Ceilingheight up to 10 Meter incl repairs and replacement ofburnt/worn out accessories and refixing the same in existing position including testing of fittings after repair, testing of connected wiring complete all as directed by Engineer in charge . Note :- (a) T & P, Ladder for any height etc are deemed to be included in the quoted rate.(iii) The representative of the contractor shall report to Engineer-in-charge/JE and carry out repairs on daily basis during the contract period and the defect shall be rectified on the same day(iii)A penal recovery of Rs 500 Per Day Per Complaint for not attening the compalint will be recovered |
| 49 | Supply & fix in repairs LED Highbay light fittings 150 watts, Energy saving, environment friendly & robust open type vertical Highbay LED IP 66 luminaire including driver and required GI tube down road of length up to 2 meter with hoooks for hanging the fitting. The fitting including fixing arrangements and taking down old rusted bracket fittings complete etc. |
| 50 | S & F in repair/replacement of LED Driver 60 Watt Suitable for street light fitting, Security light and flood light. Make :- Crompton/ Havells /Bajaj |
| 51 | S & F in repair/replacement of LED Driver 30/35 Watts Suitable for street light fitting, Security light and flood light. Make :- Crompton/ Havells /Bajaj |
| 52 | Supply & fix in repairs very high efficiency round LED Highbay light fittings 150 Watt in PDC housing, IP 66 luminaire including driver and required GI tube down road of length up to 2 meter with hoooks for hanging the fitting including fixing arrangements and taking down old rusted bracket fittings complete etc. |
| 53 | S&F in repair of building Security lightfitting 35 Watt made up of pressure die cast aluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07including fixing arrangements and taking down old rusted bracket fittings completeall as per directed by Engr- in – charge. |
| 54 | Material and Labour for checking of panels, DB\"s, Junction Box, including cleaning with blower, clamping of lugs as per existing size and capacity complete all as specified and directed.Technician will Carry scheduled preventative maintenance checks as per details to be given by Site Executive. |
| 55 | S & F in replacement MCCB 63 Amps, 25 KA Triple Pole 415 Volts including connecting up complete in existing panel with lugs/ Glands all as specified and directed. |
| 56 | S & F in replacement MCCB 100 Amps, 25 KA Triple Pole 415 Volts including connecting up complete in existing panel with lugs/ Glands all as specified and directed. |
| 57 | S & F in replacement MCCB 200 Amps, 36 KA Triple Pole 415 Volts including connecting up complete in existing panel with lugs/ Glands all as specified and directed. |
| 58 | S & F in repair MCCB 250 Amps, 36 KA, Triple Pole 415 Volts including connecting up complete in existing panel with lugs/ Glands all as specified and directed. |
| 59 | Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth and getting out in soft / loose soil complete all as specified and directed. |
| 60 | Returning filling in , excavated soil including spreading, leveling and well ramming in layers not exc 25cms each any type of soil. |
| 61 | Removing the excavated materials not exc 50mtr and depositingwhere directed at a level not exceeding 1.5 mtr above the staring point all as directed by Engr - in- Charge. |
| 62 | M&L for sand cushioning by spreading in trenches stone curshsand by gently by punning down manually as in cable protection all as specified and as directed by Engr-in-Charge. |
| 63 | Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified.. |
| 64 | Taking down existing UG cable and supply & LayXLPEinsulated,heavy duty 1100 volt grade electricarmoured LT UG cable with aluminium conductorof size 95 Sqmm 3.5 Core in trenches/along the wall/including making all connections, saddles, spacers including scaffolding if any required for saddling the cable in walls of building of height up to 25 meter, complete wih aluminium lugs as required at site and as directed by Engr-in-Charge |
| 65 | Supply and fixing 36 Watt All in one integrated Solar Street Light fitting with complete system with Battery Lithium ion, 11.1 V, 39.6 AHincluding bracket and including taking down old unserviceable fitting with fixing assembly complete all as directed by Engineer in Charge. |
| 66 | Comprehensive Repairs and maintenance of Fire alarm system installed at NAD Trombay, the system comprises of main Fire alarm Control Panelwith battery back up, Repeter panel , Motor operated Sirens, Manual call Points installed at various location complete. |
| 67 | Comprehensive Repairs and maintenance of Fire alarm system inslalled at 31 WEU Thane. The system comprises main Fire Alarm Control Panel ith battery back up, Manual Call Point (MCP), Electronic Hooter, Heat Cum Smoke Detector, Remote Response Indicators,installed at various locations complete all as specified and directed. |
| 68 | Comprehensive Repairs and maintenance of Fire alarm system installed at Naval Station Thane. The system comprises main Fire Alarm Control Panel with battery back up, Manual Call Point (MCP) , Electronic Hooter, Heat/Smoke Detector, Remote Response Indicators,installed at various locations complete. |
| 69 | Comprehensive Repairs and maintenance of Fire alarm system inslalled at NCN Thane. The system comprises main Fire laram Control Panel with battery back up, Manual Call Point (MCP) , Electronic Hooter, Heat/Smoke Detector, Remote Response Indicators,installed at various locations complete all as specified and directed. |
| 70 | Comprehensive Repairs and maintenance of Fire alarm system installed at TS Mahul. The system comprises main Fire alarm Control Panel with battery back up, Manual Call Point (MCP) , Electronic Hooter, Heat/Smoke Detector, Remote Response Indicators,installed at various locations complete all as specified and directed. |
| 71 | Comprehensive Repairs and maintenance of Fire alarm system installed at DSRV. The system comprises main Fire alarm Control Panel with battery back up, Manual Call Point (MCP) , Electronic Hooter, Heat/Smoke Detector, Remote Response Indicators,installed at various locations complete all as specified and directed. |
| 72 | Comprehensive Repairs and maintenance of Fire alarm system inslalled at T7 CMT Complex The system comprises main Fire alarm Control Panel with battery back up, Manual Call Point (MCP) , Electronic Hooter, Heat/Smoke Detector, Remote Response Indicators,installed at various locations complete. |
| 73 | Comprehensive Repairs and maintenance of Fire alarm system inslalled at Single Officer accn, NOFRA. The system comprises main Fire alarm Control Panel with battery back up, Manual Call Point (MCP) , Electronic Hooter, Heat/Smoke Detector, Remote Response Indicators,installed at various locations complete. |
| 74 | Comprehensive Repairs and maintenance of Fire alarm system inslalled at Relese Sailor Accn, Tanaji. The system comprises main Fire alarm Control Panel with battery back up, Manual Call Point (MCP) , Electronic Hooter, Heat/Smoke Detector, Remote Response Indicators,installed at various locations complete.Note for item ser No 48 to 56: a) The entire system shall be inspected and checked by the service engineer of the main manufacturer and recommend the replacement of spares and functional parts etc in proper inventory. The replaced parts shall be measured and paid for seperately as supply only under respective items of this schedule but fixing and testing etc is deemed to be included in the unit quoted rate against this item b) Checking of all internal & external wiring for open, Short, Damaged & loose Connections of all MCP, Main fire alarm panel, Repeater Panel, Siren motor, replacing of broken Break glass, cleaning of Smoke detectors.c) Testing the fire alarm system including checking of each MCP and maintaining serviceability records on monthly basis.d) All main fire control including battery, smoke detector, temperature heat detectors, connected control wiring etc shall be checked for normal functioning. |
| 75 | Supply & fixing in repairs flame proof manual call point (MCP) Housing with 24 Volt addressable MCP card and hammer, including making addition/alternation to existing supports of MCP. Make - ANG FPA or , PCD Fire System, Safetech, Zicom, Apollo. |
| 76 | Supply & fixing in repairs Switch Mode Power supply operating at input voltage range 180 to 270 Volts and having maximum out put voltage of 28.5.Make - Proxymon/Omron |
| 77 | Supply & fixing in repairs maintenance free 12 Volts 15 AH battery suitable for fire alarm panel Make - Exide, Amron,Amco |
| 78 | Supply & fixing in repairs maintenance free 12 Volts 26 AH battery suitable for fire alarm panel Make - Exide, Amron,Amco |
| 79 | M & L for Removing of burnt electric motor1 HP to 3 HP, 440 Volts of fire alarm siren after dismantling of all electrical connections & transporting from site to workshop, rewinding of electric motor with super enameled copper wire after removing of old burnt coil, replacing of bearing, cleaning of slots properly, heating in heat chamber after varnishing and testing at site and including scrapping the old paint and applying one coat of red oxide primer and applying two coat of synethetic enamel paint complete all as directed by Engineer-in-Charge. Note :- Cost of insulation paper, varnish and any nuts, bolts and lugs required for the job shall be deemed to be included in the quoted rate |
| 80 | Supply & fixing in repairs Detectors complying with and type certified to EN-45 type multisensor detector with heat and smoke combination photo electirc / optical with base with self built intelligence as per IS - 11360 complete. Make - Apollo/Zicom/Hochuki/Edward/PCD/Safetech, |
| 81 | Supply & fixing in repairs DOLstarter 3 Phase 440 volts suitable for2 HP fire alarm siren motor Make “Siemens / L&T /ABB ” as existing in panel board. |
| 82 | Supply & fixing in repairs response indicator complete with cable connection testing and commissioning all as specified and directed by Engr-in-Charge.Make - Apollo/Zicom/Hochuki/Edward/PCD/Safetech, |
| 83 | Supply & fixing in repairs Electronic hooter 24 Volt DC complete for fire alarm system complete with acessories all as directed by engineer-in charge Make - Safetech, Minimax, ECD, Apollo, Zicom/PCD |
| 84 | Supply & fixing in repairsconventional manual call point with pill box complete with hammer, chain and all fixtures Make - Safetech, Minimax, ECD, Apollo, Zicom/PCD |
| 85 | Laying only un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified.. |
| 86 | M & l for taking down of old sables & Supply & lay armoured XLPE Insulated 1.5Sqmm 4 core multi stranded copper conductor cable along the walls, in trenches ducts, ceiling / connection to control panel, manual call point complete with termination, testing and commissioning all as specified and directed by Engr-in-Charge. |
| 87 | M & L for taking down of old cables & Supply & lay armoured XLPE Insulated 1.5Sqmm 2 core multi stranded copper conductor cable along the walls, in trenches ducts, ceiling / connection to control panel, manual call point complete with termination, testing and commissioning all as specified and directed by Engr-in-Charge. |
| 88 | M&L for reinforced cement concretenominal mix M-20(using 20mm graded stone aggregate) for foundations, including rafts, footings, foundation beams, plinth beams, bases for column etc and mass concrete, complete all as specified and directed.(Note - Reinforcement and form work will be measured and paid separately). |
| 89 | M & L for TMT bars of Fe-500 D grade conforming to is:1786, 10 mm dia & over, including cutting to length, bent to shape required, cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed. |
| 90 | M & L for TMT bars of Fe-500 D grade conforming to IS: 1786, 8 mm dia bars as in binders, spacers, strippusincluding cutting to length, bent to shape required, cranking, bending spirallyfor hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc, complete all as specified and directed. |
| 91 | M & L for use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams , side and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter, for rough finished flat surfaces of concrete, complete all as specified and directed. |
| 92 | Dismantling of old UNSV/rusted steel tubular poles 9 mtr long necessary disconnecting cables/over head condcutor and removing unserviceable pole from site complete all as specified and directed. |
| 93 | Supply, Fixing and connection of hot dip galvanised MS octagonal poles of height 6 mtr with 130 mm bottom A/F & 70mm top A/F made up of 3mm thick HT sheet along with base plate of size 200 x 200 x 12mm thick including 4 nos of M20 x 600 long J type foundation bolts and 1 mtr long hot dip galvanised single arm standard bracket, including MCB of 6 Amps, with connector 4 way to be provided as termination point complete all as specified and directed. Make :- Bajaj |
| 94 | M&L for provn of Earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the plate not less than 1.5m below normal GL, connected to Galvanized earth strip 32x6mm upto 7.5 mtr with protection pipe by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 40mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I 2009 specification. |
| 95 | Supply & fix in repair 3 core 1.5 Sqmm size multistranded FRLS copper conductor PVC unsheathed 650 / 1100 Volt cable for interconnection of cable looping box to Street Light Fitting all as Directed. |
| 96 | Supply, laying, connecting and testing XLPE insulated (Earthed) cable intrenches/or fixed on pole etc in screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volt grade, cross sectional area 16 Sqmm, 4 Core Conforming to IS-7098 (Part-II)-1985 complete . |
| 97 | S & F in replacement of security light fitting/Building security lightLED type 60 watts, THD<10%, Efficacy 110 Lm/w with Pressure die cast aluminium housing with hight power LED as lighting source and lens embedded PC cover having TOP OPENING seerated driver compartment with IP 66 protection and impact resistance of IK07 with 10KV built-in surge protection device etc all as directed by Engineer in charge. |
| 98 | Taking down copper/ aluminum point wiring (Light/Fan/Socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets light fitting etc.Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces to walls floors etc. |
| 99 | M & L forpoint wiring complete with proper colour coding with 1100 Volts grade, 1.5 Sqmm PVC insulated FRLS, unsheathed, wire confirming to IS-694, Part II, ISI marked with multistranded copper conductor drawn in and including PVC concealed conduit of suitable size of wall/ RCC slab/ ceiling/ colunms/ beams etc with all accessories, fittings, PVC junction boxes etc,for mounting modular switches, sockets, fan regulators etc, also including 1.5 Sqmm, PVC insulated, FRLS unsheathed, 1100 Volts multistranded copper conductor green colour as contineous earth wire connected to common earth dolly for one light point/fan/bell point controlled by one way switch, complete all as specified and directed. Note : Rates included for concealed cutting as required at site without any damage and making good in CM 1:4 and matching the surface as required, all screws and washer for point wiring shall be Stainless steel. Nothing extra shall be admissible on this account |
| 100 | All as per Item No 81.00 here-in-before but one 5A 2pin/3pin socket out let multipurpose on the same board with other switches. |
| 101 | All as per Item No 81.00 here-in-before but one 5A 2pin/3pin switch socket out let multipurpose on independent Board. |
| 102 | All as per Item No 81.00 here-in-before but wiring complete with 2.5Sqmm for 3 pin 15A socket multipurpose on independent boardcomplete all as specified and directed. |
| 103 | Supply and fixing round shape LED Downlighter, 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 104 | Supply and fixing round shape LED Fency Spot Light, 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 105 | M&L for sub mainwiring with twosingle core 4.0 Sqmm PVC insulated FRLS multistrandedflexible copperconductorcable 660/1100 volts grade downin throughnon metalicPVC casing capingwith and includingPVC insulated 4 Sqmmsinglecore singlestrand copperconductoras continous earth wire in greencolour connected to commonearth dolly all as specified and as directed. Note : 1.Two runs ofcable, one run of earth wire4.00 Sqmm and one run of PVC casing capping will be measured and paid one unit. |
| 106 | M&L for sub mainwiring with twosingle core 1.5 Sqmm PVC insulated FRLS multistrandedflexible copperconductorcable 660/1100 volts grade downin throughnon metalicPVC casing capingwith and includingPVC insulated 1.5 Sqmmsinglecore singlestrand copperconductoras continous earth wire in greencolour connected to commonearth dolly all as specified and as directed.Note : 1.Two runs ofcable, one run of earth wire 1.5 Sqmm and one run of PVC casing capping will be measured and paid one unit. |
| 107 | M & L forpoint wiring with PVCinsulated FRLS unsheathed 1100 Volts grade single core multistranded copper conductorcable 1.5 Sqmm drawn in and including PVC casing-caping, fixed on wall / ceiling with all accessories, fittings, PVC junction boxes etc, with suitabe sunk pressed steel boxes for modular fittings not less than 1.6 mm thick, etc with necessary fixing accessories andearth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including 1.6 mm thick pressedsteel terminal boxes concealed in wall covered withlaminated sheet top cover 3 mm thick for mounting switches / sockets / fan regulators fixed with Cadmium platedmachine screwsall as specified for one light / fan / bellpoint controlled by one switch. |
| 108 | All as per Item No 89.00 here-in-before but for one 5A 2pin/3pin socket out let multipurpose on the same board with other switches. |
| 109 | All as per Item No 89.00 here-in-before but for one 5A 2pin/3pin switch socket out let multipurpose on independent Board. |
| 110 | All as per Item No 89.00 here-in-before but wiring complete with 2.5Sqmm for 3 pin 15A socket multipurpose on independent board Note for item No. 89.00 to 92.00 : A penalty of Rs 100 /- per point will be recovered from the contractor for not matching the disturbed surface with original. |
| 111 | S&F modular type6A one way SP switch 1 moduleconfirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed. |
| 112 | S&F modular type 2/3 pin combined shuttered type 6 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed. |
| 113 | S&F modular type 2/3 pin combined shuttered typr 16 Amps socket 2 module conforming toIS: 1293-2005 complete all as specified and directed. |
| 114 | S&F modular type16 A one way SP switch 1 module confirming to IS: 3854-1997 with finguer proof terminal complete all as specified and directed. |
| 115 | S&Fmodular type 120W step fan regulator of 2 module size conformng to IS: 11037-1984 complete all as specified and directed. |
| 116 | Supply & Fix Modular Bell push flush type 6 Amp, 1 module, 230 Volts complete all as specified and directed. |
| 117 | Supply and fix bell ding dong AC 230 V single pole.complete all as specified and directed. |
| 118 | S & F Modular Blank plate 1 module suitable for Modular switch boards all as specified and as directed |
| 119 | S & F Modularcover plate 8 modules |
| 120 | S & F Modularcover plate 4 modules |
| 121 | S & F Modularcover plate 3 modules |
| 122 | S & F Modularcover plate 6 modules |
| 123 | S & F Modularcover plate 1 modules |
| 124 | S&F ceiling rose three terminal, 230 Volts PVC / Polycarbonate body, complete all as specified and directed. |
| 125 | S & F 20-22 W capacity surface/wall mounted LED batten having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, CCT 4000K to 6000K, independent isolated SMPS based constant current electronic LED driver with THD < 20%, CRI> 80, lamp burning hours not less than 50000, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminum channel housing and white colored ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor PVC insulated cable of appropriate size from ceiling rose to the fixture & fixing on 02 Nos PVC round blocks complete all as specified and directed |
| 126 | Supply and fixing Electronic Meter 10-60 amps Single phase tamper proofwith Class 1 accuracy Optical port,LED Indication for earth leakage ,Elegant Polycarbonate Enclosure,High Surge withstand up To 8kv ,anti tamper features,Electromagnetic compatible & 6 digit Display. Make L&T/ HPL or equivalent as approved by GE.Note : Old unserviceable Meter will be deposited to MES. |
| 127 | M&L for testing of old earthing using calibrated earth tester & submitting result to engr -in -charge all as directed.Note : (i) Watering of earthing with 2 Buckets (30Ltrs) water mixed with salt (total 20Kg) shall be carried outone day before the testing & the cost of the same shall deemed included in unit rate quoted. |
| 128 | M&L for painting on wall with synthetic enameledpaint of black colour as background of 200 x 150 mm size and writing for earth test result with date & year all as specified and directed at site by Engineer-in-Charge. |
| 129 | M&L for locating of faults of LT under ground cable PILCA/XLPE upto 400 Sqmm size by using computerised / primary current injection method including cutting and removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing all as required and directed at site.Notes:-(i) Excavation, earth work, sand cushioning, PCC coveretc will be measured and paid separately under relevant items of BOQ.(ii) Cable jointwill be measured and paid separately.(iii) Additional length of cable required at site for jointing will be measured and paid separately. |
| 130 | M&L for straight through joint (HEAT SHRINKABLE TYPE KITS) for underground cable including joint kits and labour complete for making joints suitable for LT, XLE/PILC/PVC sheathed armoured heavy duty cable with aluminium conductor 3.5/4 core up to to 50 Sqmm incl taking down existing terminal joints. |
| 131 | All as per Item No 112.00 here-in-before but 3.5/4 core 70 Sqmm to 150 Sqmm size -do- |
| 132 | All as per Item No 112.00 here-in-before but 3.5/4 core 185 Sqmm to 400Sqmm size -do- |
| 133 | Supply & Lay or fixing or passing through pipe, XLPE/PVC insulated, armouredheavy duty 1100 volt grade electric LT UG cable with aluminium conductorof size 10 Sqmm 4 Core in trenches/along the wall/including takingdown old unsv cable andmaking all connections complete with lugs as required at site and as directed by Engr-in-Charge. |
| 134 | M&L for cutting existing road/hard standing not exc 45x45 cm in wide & depth getting out excavated material for laying GI tube ;returning filling & well rammaing wateringfinish suraface 10 cm from top using PCC 1:3:6; including removal of surplus soil all as directed |
| 135 | S& F in replacement of GI steel tubing light grade 40 mm dia for laying in ground, along the pole in coping, road crossing etc for cabe protectionincluding necessary fittings , clamps for supports, etc all as directed by Engineer in charge Make - Tata/Jindal/Surya Prakash |
| 136 | Supply and fix in replacement ofFRP looping box of size 155x210x92 mm with connector, MCB 6 Amps, Din Rail, GI clamps made out of GI flat of size 25mm X 3 mm channelincluding providing detachable GI 3 mm thick plate inside looping box as cable gland plate and including cable gkands as required at size and making connections all as specified and directed by Engineer –in –Charge.Make -National / Sintex |
| 137 | M&L for taking down old unsv and supply & lay 3Core 1.5 Sq mm size multistranded copper conductor PVC unsheathed 650 / 1100 Volt Grade As per IS 694 with and including 20 mm dia PVC conduit and passing through PVC conduit with necessary saddle, clamps, bolts & nuts,all For interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc All as Directed. |
| 138 | M&L for Multistandarded Copper Conductor cable of3 Core 1.5 Sq mmsize drawn through steel tubular poles for interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc taking down old unsv cable all as Directed. |
| 139 | M&L for sub mainwiring with twosingle core 2.5 Sqmm PVC insulated FRLS multistrandedflexible copperconductorcable 660/1100 volts grade downin throughnon metalicPVC casing capingwith and includingPVC insulated 2.5 Sqmmsinglecore singlestrand copperconductoras continous earth wire in greencolour connected to commonearth dolly all as specified and as directed. Note : 1.Two runs ofcable, one run of earth wire 2.5 Sqmm andone run of PVC casing capping will be measured and paid one unit. |
| 140 | M&Lin repairs 1 output 16 A-250 V 50/60 Hz Digital Time Switch with Astronomical function 56 for switching on/off lights and other electric devices with daily astronomical calculation of the sunrise/sunset times based on the entered location or location coordinates complete all as directed by Engr-in - Charge. |
| 141 | M&Lin repairs for 24 Hrs240 V FM1 Quartz type Time switches astronomical type (Having longitude and latitude of Indian cities in memory) timer for controlling street lights contactors complete all as directed by Engr-in - Charge. |
| 142 | M&L to attend the LED Solar Light fittings of 18wattage. Service Representative will Carry scheduled preventative maintenance checks as per details given below at Mankhurd a)Solar PV Modules - Check the Circuit Voltageand current characteristics. Also, check the mechanical integrity of the Solar PV Modules.b)Battery Bank -Check the Specific Gravity of the Electrolyte, Electrolyte level, battery terminals, Battery Bank box and adding Electrolyte solution if required. NOTE Electrolyte solution will be measured seprately under this Schedule.c)Solar PCU - Check DC input Voltage and Current, Check AC input Voltage and Current, checking the wiring.d)Module Mounting Structures -Check the mechanical integrity of the Solar PV Modules Mounting Structures. Ensure that there is no corrosion set up on the MMS and the module is firmly fixed.e) System Wiring - Check the system wiring including the insulations, cable lugs and rewiring/soldering if any requiredf)Module Cleanliness - Cleaning of the dust accumulatedover the Solar Module, and taking corrective measures |
| 143 | M&L for preparation of old painted surfaces of Solar Street Light Poles including accessories by scrapping old paint and applying two coats ofpaint including numbering of pole with black oil paint complete all as directed by Engineer in Charge |
| 144 | Supply and fix in replacement of LED 18 watt DC solar light fitting Make - Emvee / ICPC Solar |
| 145 | Supply and fix inreplacement of low maintenance VRLA lead acidic batteryof 120 AH suitable for 1 x 18 watt Soalr Lightfitting all as per recommanded by Manufracturer |
| 146 | Supply and fix inreplacement of charge controller suitable for 18 watt Solar Light fittings incluing any wiring as required |
| 147 | Supply only electrolyte solution to be incorporated in servicing, suitable for Solarcharged battery of any capacity. |
| 148 | Supply and fix in replacement flood light fittingsin street light poles/Buildings the fitting shall be of LED type 120 Wattscomplete with and including drivers, pressure die cast aluminium housing,prewired complete. |
| 149 | Dismentling of PCC foundation / pole coping from ground level all as per specified and directed |
| 150 | M & L for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed. |
| 151 | Supply and fix in replacement 8/9 Watt LED Bollard garden light fitting with efficient high output COB LED, pressue die cast powder coated housing with PC diffuser driver nut bolt ,washer base plate foundation 0.3 mtrx0.3 mtr x.40 mtr by PCC 1:2:4 type B-1 using 20mm grade stone aggegates of size including excavation and earth work , provision of GI bend of size 50MM dia in the PCC for cable entry all as specified and directed in Engr-in-Charge. |
| 152 | Suply and fix New generation , Post-top LED warmlight 35/40 W,energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LEDs as light provision of GI bend of size 40 mm dia in the PCC for cable entry the fittingwith nut bolts, washerall as specified and directed in Engr-in-Charge. |
| 153 | Suply and fix New generation , Post-top LED warmlight 15/ 20 W,energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LEDs as light provision of GI bend of size 40 mm dia in the PCC for cable entry the fittingwith nut bolts,washerall as specified and directed in Engr-in-Charge. |
| 154 | Taking down of OldMCB DB of any size |
| 155 | Supply & Fix switch piano single poleflush type 5A,240 V one way. |
| 156 | Supply & Fix Bell push flush type 5 amp, 230 Volts |
| 157 | Supply & Fix switch socket combination 2 in 1 ,5Amps multipurpose flush type. |
| 158 | Supply & Fix switch socket combination 2 in 1,3 pin, 5 and 15 Ampsflush type universal. |
| 159 | S & F in repairs Ceiling fan regulator electronic stepped type, AC, 230 Volts, flush type. |
| 160 | Supply and fix bell ding dong AC 230 V single pole. |
| 161 | M & L for GI steel tubing medium grade 40mm dia and length up to 1.5 meter bent to shape of offset angle upto 45degree for fixing of security /street light fittings including MS clamps made of 32mm x5mm flat iron, nuts , bolts, etc all as directed by Engineer in charge |
| 162 | Taking down carefully and Re-fixing of the same ceiling fan 1200mm sweepincluding provision of cable from ceiling nose/ conductor to fan and spray painting of ceiling fan with two coats of synthetic enamel paint, after preparation of surfaces, complete all as specified and directed. |
| 163 | Supply And Fix in repairs MCCB DB TPN 4Way double door125 Amps prewired suitable for Triple Pole 125 A MCCB as incomer with the following acessories, a) MCCB TP 125 A 25 KA 415 Volt - 1 Nosb) Bus bar, Din rail , Neutral link |
| 164 | Supply And Fix in repairs MCCB DB TPN 8 Way double door125 Amps prewired suitable for Triple Pole 125 A MCCB as incomer with the following acessories & connecting of existing cables & providing of acbel glands, a) MCCB TP 125 A 25 KA 415 Volt - 1 Nosb) Bus bar, Din rail , Neutral link |
| 165 | Supply & Fix MCB DB SPN 2 way 240 volts Single door, including connecting up with existing cable with new lugs. |
| 166 | Supply & Fix MCB DB Double Door SPN 4 way 240 volts including connecting up with existing cable with new lugs. |
| 167 | Supply & Fix MCB DB Double Door SPN 8 way 240 volts including connecting up with existing cable with new lugs. |
| 168 | Supply & FixMCB DB Double Door SPN 12 way 240 volts including connecting up with existing cable with new lugs. |
| 169 | Supply & Fix MCB DB TPN 4 way 415 V double door with busbar including connecting up with existing cable with new lugs. |
| 170 | M&L for MCB SP, 240 volt, 5 to 32 Amps, 10 KA, C Curve, |
| 171 | M&L for MCB SPN, 240 volt, 6 to 63 Amps, 10 KA, C Curve, |
| 172 | M&L for MCB TPN, 240 volt, 40 to 100 Amps, 10 KA, C Curve, |
| 173 | S&F single pole and neutral enclosure with a two pin and earthand metal cladplug socket complete with one single pole MCB 20 Amp 240 Volts complete all as specified and directed. |
| 174 | M&L for sub mainwiring with twosingle core 6.0 Sqmm PVC insulated FRLS multistrandedflexible copperconductorcable 660/1100 volts grade downin throughnon metalicPVC casing capingwith and includingPVC insulated 6 Sqmmsinglecore singlestrand copperconductoras continous earth wire in greencolour connected to commonearth dolly all as specified and as directed. Note : 1.Two runs ofcable, one run of earth wire, 6.00 Sqmm and one run of PVC casing capping will be measured and paid one unit. |
| 175 | M&L for earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification. |
| 176 | S&F GI strip size 25 x 4 mmall as directed including welding brazing and taking down of old copper strips as required at site |
| 177 | S&F in Repairs/Replacement Ultra brightglass LED tube rod 20 Watts(Single/Double side connection), 230 volts with very high efficacy with G13 lamp holder including fixing arrangements and taking down old unserviceable tube rod complete. |
| 178 | S & F 10 W capacitysurface/wall mounted LED batten having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, CCT 4000K to 6000K,independent isolated SMPS based constant current electronic LED driver with THD < 20%,CRI> 80, lamp burning hours not less than 50000, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminum channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor PVC insulated cable of appropriate size from ceiling rose to the fixture & fixing on 02 Nos PVC round blocks complete all as specified and directed. |
| 179 | S & F in replacement of 36 W ceiling recessed light of size (1x4 ft) having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminum channel housing and white colored ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail