Tamil Nadu Police Housing Corporation Limited-TNPHC has published Tender For Construction Of Joint Chief Environmental Engineer (Monitoring) Office Building With Development Works For Tamil Nadu Pollution Control Board At Sidco Industrial Estate, Pettai In Tirunelveli. Submission Date for this Tender is 08-02-2023. Control Board Tenders in tirunelveli Tamil Nadu. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | 1.1) Earth work excavation for foundation in all soils (including refilling) a. 0 to 2 mt. |
2 | 1.3) Earth work excavation in Soft disintegrated rock (including refilling) a. 0 to 2 mt. |
3 | b. 2 to 3 mt. |
4 | 1.5) Earth work excavation for Open foundation (excluding refilling) a. 0 to 2 mt. |
5 | 1.8) Earth work excavation in SDR for Open foundation(excluding refilling) a. 0 to 2 mt. |
6 | 7.2) Supplying and fixing of Bituminous filler pad, 20 mm tk. for expansion joint |
7 | 13.1) Filling with excavated earth |
8 | 21.2) Teak wood Wrought & Put up a. T.W. over 2.00 m & below 3.00 m |
9 | b. T.W. below 2.00 m length. |
10 | 25) Supplying and fixing of MS hold fast |
11 | 30) Finishing the top of flooringwith cement concrete 1:3, 20mm thick Ellispattern flooring (No sand) |
12 | 31) Weathering course over roof slab with proportion of brick jelly 20mm to lime (32:12 1/2) by volume |
13 | 37.1) White washing 3 coats(slaked) |
14 | 39) Supplying and fixing of MS Grills in position |
15 | 40) Painting 2 coats - New "wood work" |
16 | 41) Painting 2 coats - New "iron work" |
17 | 46) Supplying and fixing of 20 mm dia Alu. Hanger Rod |
18 | 47) Supplying and fixing of Alu. Towel rail 75 cm long |
19 | 48) Supplying and fixing of 5 pin Coat stand |
20 | 49) Supplying and fixing of Chromium plated 8 gauge picture hook |
21 | 50.3) Supplying and planting avenue trees |
22 | 50.4) Providing Tree guard |
23 | 52) Supplying and laying of PVC Water supply (ASTM) pipe a. 32 mm dia |
24 | b. 25 mm dia |
25 | c. 20 mm dia |
26 | 53.3) Supplying and fixing of C.I. steps (5 Kg) |
27 | 55.2) Supplying and fixing of Flat Back Urinal |
28 | Electrical arrangements 69) Supplying and fixing of 15 Amps3 pin Power plug socket |
29 | 72) Supplying and fixing of Box type Fibre Fan hook |
30 | 73.1) Supplying and fixing of 3 phase Distribution board with 6 way per phase32A per way with neutral link |
31 | 74) Charges for assembling and fixing of ceiling"Fan" |
32 | 76) Supplying and fixing of 8 SWG G.I. wire |
33 | 77.3) Supplying and fixing of TV/Telephone line Socket |
34 | 77.4) Supplying and fixing of 20mm dia PVC pipe for TV/Telephone line |
35 | 78) Providing Earthing Station using pipe electrode as per IS3043 (Type I) |
36 | 81) Supplying and fixing of meter cupboard with best Country wood double leaves shutters |
37 | 83) Supplying of MS angle 40 x 40 x 6mm |
38 | 86) Providing Pre-constructional Anti termite treatment |
39 | 112) Supplying and fixing of Exhaust Fan 300 mm dia |
40 | Annexure 2.1.1) Supplying and filling the basement with gravel |
41 | 2.1.3) Supplying and filling in foundation and basement with Crushed stone sand |
42 | 3.1.1) C.C.1:5:10 using 40mm size HBSJfor Foundation & Basement using crushed stone sand |
43 | 3.2.1) P.C.C. 1:2:4 using 20mm size HBSJ for Foundation & Basement and other similar works using crushed stone sand |
44 | 3.3.1) P.C.C. 1:8:16 using 20 mm broken brick jelly using crushed stone sand |
45 | 4.4.1) Standardized Concrete mix M20 Grade using crushed stone sand a. In Foundation and basement |
46 | 6.6.1) Brick work in C.M. 1:5 (F& B) using Kiln Burnt Country bricks of size 22 x 11 x 7 cm (8 ¾ " x 4 ¼" x 2 ¾ ") using crushed stone sand with Admixture |
47 | 8.4.1) Standardized Concrete mix M20 Grade using crushed stone sand a. In Ground Floor |
48 | b. In First Floor |
49 | c. In Second Floor |
50 | 9.6.1) Brick work in C.M. 1:6using Kiln Burnt Country bricks of size 22x11x7cm (8 ¾ " x 4 ¼" x 2 ¾ ") using crushed stone sand with Admixture a. In Ground Floor |
51 | b. In First Floor |
52 | c. In Second Floor |
53 | 10.6.1) Brick partition work in C.M. 1:4 using Kiln Burnt Country bricks of size 22x11x7 cm (8 ¾"x4 ¼ "x2 ¾") 110 mm tk (B.P.) using crushed stone sand with Admixture a. In Foundation and basement |
54 | b. In Ground Floor |
55 | c. In First Floor |
56 | 11.6.1) Brick work in C.M. 1:4 using Kiln Burnt Country bricks of size 22x11x7cm (8 ¾ " x 4 ¼" x 2 ¾ ") 70 mm tk using crushed stone sand with Admixture(B.P.) a. In Ground Floor |
57 | b. In First Floor |
58 | 14.2.2) Precast Cupboard slab 20mm tk in standardised concrete mix M20 Grade by using 3mm - 10mm HBGS Jelly using crushed stone sand 20mm thick a. In Ground floor |
59 | b. In First floor |
60 | 14.2.3) Precast Cupboard slab 40mm tk in standardised concrete mix M20 Grade by using 3mm - 10mm HBGS Jellyusing crushed stone sand 40mm thick a. In Foundation & Basement |
61 | 18.1) Formwork using M.S.Sheet a. For Column footings, plinth beam, Grade beam, Raftbeam, Raft slab etc., |
62 | b. Plain surfaces such as Roof slab, floor slab, Beams, lintels, lofts, sill slab, staircase, portico slab and other similar works |
63 | c. For Square and rectangular columns and small quantities |
64 | d. For Vertical wall |
65 | f. For Curved surface |
66 | 21.5.2) Supplying and fixing of soild UPVC door shutter with frame |
67 | 21.5.3) Supplying and fixing in position of UPVC window of casement type (open) for all sizes |
68 | 21.5.4) Supplying and fixing in position of UPVC louvered ventilator type for all sizes |
69 | 22.9) Solid core TW flush door with Teak ply on both sides and TW lipping alround (35mm thick) Single leaf shutter Suitable for door of size a) 1000 x 2100mm |
70 | 22.3.3) Cup board/ward robes double leaf shutters using 9mm thick phenol bonded BWR grade plywood, TW frames, styles & rails including two coat enamel paint over one coat primer with brass screws |
71 | 26.1) Flooring in C.C.1:5:10 using 40mm size HBSJ using crushed stone sand |
72 | 28.1) Finishing the top of flooring in C.M. 1:4, 20mm thick. using crushed stone sand |
73 | 29.8.1) Supplying and fixing of Glazed tiles using Grout (Tile Joint Filler) using crushed stone sand |
74 | 29.9.1) Supplying and laying of Floor ceramic tiles (Anti-skid) using Grout (Tile Joint Filler). using crushed stone sand |
75 | 32.1.1) Pressed tiles (23cmx23cmx20mm thick) mixed with water proofing compound @ 2% by weight of cement using crushed stone sand |
76 | 33.1) Plastering in C.M. 1:5, 12 mm tk. using crushed stone sand |
77 | 34.1) Plastering in C.M. 1:4, 12 mm tk. using crushed stone sand |
78 | 35.1.1) Plastering in CM 1:3, 12 mm tk. with WPC using crushed stone sand |
79 | 35.2) Spl. Ceiling plastering in C.M 1:3, 10 mm tk. using crushed stone sand |
80 | 36.1) Plastering for Border in C.M. 1:5, 12 mm tk. using crushed stone sand a. 150 mm wide |
81 | b. 75 mm wide |
82 | c. 50 mm wide |
83 | 38.4.2) Supplying and applying Wall putty (one coat) over the new cement plastered walls |
84 | 43.1) Supplying, Fabricating and fixing of Mild steel / RTS grills (without cement slurry wash) reinforcement for all sizes of rods |
85 | 44.2.1) Rain water harvesting using defunct borewell and providing perforated cover slab in Standardised concrete mix M20 Grade by using 3mm-10mm HBGS Jelly using crushed stone sand a) Providing pit |
86 | b) Augering 30cm dia |
87 | 44.6) Supplying and fixing of PVC SWR 110 mm dia with ISI mark type-A for rain water down fall pipe |
88 | 50.2.1) Providing precast Kerb stone in C.C. 1:3:6, 450x300x150 mm using crushed stone sand |
89 | 50.5.1) Supplying fabricating and erection of M.S Scheme name board using crushed stone sand |
90 | 50.6.1) Precast slab 50 mm tk.in C.C. 1:3:6 mixed with fibre using crushed stone sand |
91 | 53.4) Supplying and fixing of CI Manhole cover of size 60 x 60cm (50kg weight) |
92 | 53.5) Supplying and fixing of porcelin Wash hand basin (White without Pedestal Type), superior variety of size 550x400mm (22”x16”) |
93 | 54.1.1) Supplying and fixing of 15mm dia Half turn Brass core C.P. Tap (long body) |
94 | 54.2.1) Supplying and fixing of 15mm dia Half turn Brass core C.P. Tap (Short body) |
95 | 55.1.1) Supplying and fixing of Squatting Urinal |
96 | 56.3.2) Supplying and fixing of Indian Water closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR Grade "P" or "S" trap - in G.F. using crushed stone sand |
97 | 56.4.2) Supplying and fixing of Indian Water closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR Grade "P" or "S" trap - Other than G.F. using crushed stone sand |
98 | 57.2) Supplying and fixing of EWC (White) 500mm with PVC SWR grade "P" or "S" Trap |
99 | 58.3) Supplying and fixing of PVC SWR pipe (Soil line) with ISI mark - type "B". a. 110 mm dia. |
100 | b. 75 mm dia |
101 | 58.4) Supplying, Laying & Concealing the 50mm dia PVC (SWR) pipe with ISI mark type - "B" with relevant specials. |
102 | 59.5.2) Supplying and fixing of Gully Trapusing crushed stone sand |
103 | 60.1) Supplying and fixing of PVC Nahani trap (4way/2way) |
104 | 61.1.1) Supplying and fixing of UPVC Non Pressure Pipe of SN8 SDR 34 (S 16.5) as per IS 15328/2003 a) 110mm dia UPVC Non Pressure pipe |
105 | b) 160mm dia UPVC Non Pressure pipe |
106 | 64.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. a. Light point with ceiling rose |
107 | b. Light point without ceiling rose |
108 | c. Calling bell point with Buzzer/Calling bell |
109 | 65.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan Point |
110 | 66.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Staircase Light Point. |
111 | 67.1) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point at Switch Board Itself. |
112 | 68.2) Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point at Convenient Places. |
113 | 75.1.2) Supplying and delivery of fan with electronic dimmer with ISI mark a) 48" (1200mm) sweep |
114 | 77.5) Run off 2 Wires of 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 in fully concealed |
115 | 77.6) Run off 2 Wires of 4 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 in fully concealed. |
116 | 77.7) Run off 2 Wires of 2.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 in fully concealed |
117 | 79.1.1) Supplying and fixing of 1 No. of 32 Amps Fuse Unit |
118 | 79.2.1) Supplying and fixing of 3 Nos. of 32 Amps Fuse Unit |
119 | 79.2.3) Supplying and fixing of 3 Nos. of 63 Amps Fuse Unit |
120 | 80.1) Supplying and fixing of 450x375x20mm T.W. plank |
121 | 84.5) Run of Main 4 wires of 10 Sqmm PVC insulated unsheathed single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. |
122 | 85.2)Supplying and fixing of G.I pipe 25 mm dia, "B" class for EB service connection |
123 | 87.1)Supplying and fixing of Three Phase ELCB/RCCB |
124 | 87.2)Supplying and fixing of 20 Amps DP plug and socket in sheet enclosure with 32A DP MCB in Flush with wall with earth connection (For AC Plug) |
125 | 97.4) Providing and fixing of Aluminium composite panel (ACP) at all level elevation and heights |
126 | 99.1) T.W.single leaf Panelled door shutter with brass fittings Suitable for door of size a. 1000 x 2100mm |
127 | 100) Supplying and fixing of 9 watts LED Bulb |
128 | 101) Supplying and fixing of 25 watts LED bulb with street light fittings |
129 | 102) Supplying and fixing of 4"18 watts crystalLED tube light |
130 | 103) Supplying and fixing of Bulk Head fitting suitable for 12 watts LED bulb |
131 | 104) Supplying and fixing of 12 watts bulb lamp for bulk head fittings |
132 | 105.1) Run off main 4 wires of 4 Sq mm. (EB service connection) |
133 | 114) Supplying and delivery of followingPVC Aluminium armoured LTUG cable a) 3.5 core 70 Sqmm PVC Aluminium armoured LTUG cable |
134 | 115) Labour charges for laying of 3.5 core 70 Sqmm PVC Aluminium armoured LTUG cable below ground level |
135 | 116) Labour charges for laying of 3.5 core 70 Sqmm PVC Aluminium armoured LTUG cable above ground level |
136 | 117) Supplying and fixing of Brass cable Gland suitable for PVC Aluminium armoured LTUG cable a) 3.5 core 70 Sqmm brass cable gland |
137 | 117.1) Supplying and fixing of Crimping Lugs suitable for following PVC Aluminium Armoured LTUG cable a) Crimping Lugs for 3.5 core 70 Sqmm. Aluminium Armoured LTUG cable |
138 | 119.3) Supplying and delivery of single phase 2 HP air compressor pumpset |
139 | 119.4) Supplying and delivery of single phase 1.5 HP Electric Monoset Centrifugal pump of best approved brand suitable for sump with ISI mark etc., all complete |
140 | 120.1) Labour charges for erection ofHorizontal shaft, Centrifugalpumpset upto 3 HP (coupled/monoblock) |
141 | 121.2) Supplying and delivery ofDirect online starter with single phasing preventor 2 HP for Monoblock motor |
142 | 121.3) Supplying and delivery ofDirect online starter with single phase panel board 1.5 HP |
143 | 122) Supplying and fixing of following diaof the GI, UPVC, HDPE, MS& GM specials a) 50mm dia UPVC Tee |
144 | b) 50mm dia UPVC Elbow |
145 | c) 50mm dia UPVC MTA |
146 | d) 50mm dia GM Gate valve (Heavy Duty) |
147 | e) 50 mm dia GM Non return valve |
148 | f) 50 x 32mm dia UPVC Bush |
149 | g) 50 mm dia UPVC Coupler |
150 | h) 32mm dia GI Elbow |
151 | i) 32mm dia UPVC Union |
152 | j) 32mm dia CPVC Nipple |
153 | k) 32 mm dia - 150mm GI pipe Nipple |
154 | l) 32mm dia GI Coupling |
155 | m) 32 mm dia 24" GI pipe Nipple |
156 | n) 32 mm dia UPVC MTA |
157 | o) 32 mm dia UPVC Elbow |
158 | p) 32 mm dia UPVC Coupler |
159 | q) 32 mm dia HDPE collar |
160 | r) 32 mm dia HDPE hose clip |
161 | s) 15 mm dia GI Elbow |
162 | t) 15 mm dia GI Union |
163 | u) 15 mm dia MS Union |
164 | v) 15 mm dia GI Coupling |
165 | w) 15 mm dia 3" pipe Nipple |
166 | x) 15 mm dia 6" GI pipe Nipple |
167 | y) 15 mm dia 24" GI pipe Nipple |
168 | z) 15 mm dia UPVC Hex Nipple |
169 | a1) 15 mm dia HDPE hose clip |
170 | b1) 15 mm dia HDPE collar |
171 | c1) 15 mm dia UPVC Elbow |
172 | d1) 15 mm dia UPVC Coupler |
173 | e1) 15 mm dia UPVC MTA |
174 | f1) 63 x 50mm dia GI Bush |
175 | g1) 50 x 40mm dia GI Reducer Tee |
176 | h1) 50 mm dia MS Flange set |
177 | i1) 50 mm dia UPVC Ball valve |
178 | j1) 80 mm dia GI Bend |
179 | k1) 80 mm dia GI Coupling |
180 | 124) Supplying and delivery of following dia GI pipes "B" class in position a) 15mm dia GI pipe |
181 | b) 50mm dia GI pipe |
182 | c) 80mm dia GI pipe |
183 | d) 100mm dia GI pipe |
184 | 124.2) Supplying, delivery & fixing the following dia HDPE hose pipe for sub-mersible pump in borewell class-5 (1 Mpa (or) 10 Kg/cm2 pressure) a) 32mm dia HDPE hose pipe |
185 | b) 15mm dia HDPE hose pipe |
186 | 124.6) Supplying and fixing of MS Bore cover suitable to bore casing pipe of 160mm dia having a slot of 1 1/4" & 1/2" GI pipe / HDPE hose pipe |
187 | 125) Supplying and delivery of following dia UPVC Pipe a) 32mm dia UPVC pipe |
188 | b) 15mm dia UPVC pipe |
189 | c) 50mm dia UPVC pipe |
190 | 125.1) Labour charges for laying of GI and PVC pipe below ground level |
191 | 125.2) Labour charges for laying of GI and PVC Above ground level |
192 | 126.1) Supplying and fixing of following dia M.S. Clamp set a) 80 mm dia MS clamp set |
193 | b) 50 mm dia MS clamp set |
194 | 126.2) Supplying and fixing of folllowing dia MS Bore Clamp a) 15mm dia MS Bore clamp |
195 | b) 32mm dia MS Bore clamp |
196 | 132) Drilling of 150mm dia borewell in hard rock areas |
197 | 132.1) Drilling of 150mm dia borewell in over burden soil including labour charges for inserting casing pipes and including cost of Rig, Fuel etc., |
198 | 133) Supplying and fixing of 150mm dia casing pipe plain/slotted of 6Kg/cm2 |
199 | 134) Supplying and fixing of 160mm dia PVC end cap suitable for covering the 150mm dia borewell casing pipe |
200 | 160.1) Supplying and fixing of Rotary handle |
201 | 161) Supplying and fixing of Single Pole MCB 6A to 32A, 10KA |
202 | 163) Supplying and fixing of 63 Ampstriple pole main switch with fuse unit |
203 | 164) Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase304L Grade |
204 | 255.1) Providing and fixing in position of Plain sheet 10mm thick Hiluxboard false ceiling |
205 | 344.2) Supplying and fixing of Bevelled Edge Mirror of size 500x400x5.5mm |
206 | 361.1) Supplying and laying of Concrete designer tiles flooring in C.M. 1:3 (one of cement and three of crushed stone sand) 20mm thick |
207 | 367) Providing wooden melamen polish for main door new wood work |
208 | 373) Supplying and installation of Air conditioner with copper coil 1.5 TR split type AC unit5 star rated |
209 | 374.1) Supplying and laying of 5/8" and 3/8" Copper pipe (Extra beyond 3 metres supplied with AC unit) in position |
210 | 374.2) Supply and fixing of MS stand for fixing outdoor unit |
211 | 374.4) Supply and fixing of Exhaust Pipe with Silencer |
212 | 375) Supplying and installation of 4 KVA capacity automatic voltage stabilizer with time delay relay arrangements |
213 | 378.3)Supplying and fixing of Stain Free Nano Polish Vitrified Tiles 600 x 600 x 8mm in CM 1:3, 20mm tkusing crushed stone sand |
214 | 379.7) Supplying and fixing of Granite slab of size 4" x 2" 18-20mm tk (Jet Black) for table slab arrangements in CM 1:3,12mm tk using crushed stone sand a. In Ground Floor |
215 | 383.2) Providing Double nosing to the edges of granite slab |
216 | 465.2) Providing Wall Panelling using one side teak wood sheet with melamine polishing |
217 | 516) Supply of 62.5 KVA Diesel Generator set with Auto main Failure (AMF) panel |
218 | 518.1) Charges for Erection, testing and Commissioning, of 62.5 KVA Genset arrangements with power main including civil works |
219 | 531) Supply and run off 25mmx3mm tinned copper flat with necessary clamps / supports on wall / Floor / ground for earth connection |
220 | 550) Designing the semi unitised structural glazing system with open groove joint as per design intent |
221 | 551) Supply and erection of 125 Amps capacity floor mounting Panel board (Cubical type) |
222 | 796)Two coat of Exterior emulsion paint including primer for outer wall surfaces |
223 | 796.1)Two coat of Plastic emulsion paint including primer for inner wall surfaces |