Tender For Renovation Work Of X-Ray Room, habra-West Bengal

Urban Local Bodies has published Tender For Renovation Work Of X-Ray Room. Submission Date for this Tender is 10-02-2023. Building Work Tenders in habra West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

35994100
Tender For Renovation Work Of X-Ray Room
Open Tender
Indian
West Bengal
habra
10-02-2023

Tender Details

Renovation Work Of X-Ray Room For Setting Up Polyclinic And Diagnostic Centre In Uphc At Super Market, Kamarthuba Within Ward No-06 Under Habra Municipality

Key Value

Document Fees
Refer document
EMD
INR 2835.0 /-
Tender Value
INR 1.41 Lakhs /-

BOQ Items

Name of Work:-Renovation work of X-Ray Room for setting up Polyclinic & Diagnostic Centre in UPHC at Super market, kamarthuba within Ward No.-06 under Habra Municipality
Sl. No. Item Description
1Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991) 4 bars 415 V, 100/125 A 4 x 20x5mm 500x150mm [Ref:PWD 2017,ELECTRICAL SCHEDULE,CHAPTER D-12,Item No.-19(a)]
2Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.(Angle iron frame) 63 Amp,Make L & T [Ref:PWD 2017,ELECTRICAL SCHEDULE,CHAPTER D-3,NO-4(a)] [For X-Ray incommer & outgoing]
3100 Amp ,Make L & T [Ref:PWD 2017,ELECTRICAL SCHEDULE, CHAPTER D-3,NO-4(a)] [For supplyincommer]
4Supplying and fixing Sheet steel Main Switches on flat iron frame on wall 240V,fuse DP with on L&N 30/32 A,Havells make. [Ref:PWD 2017,ELECTRICAL SCHEDULE,CHAPTER D-1,No-1(a)] [For light,fan socket A.C point of X-Ray room outgoing]
5Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 2+4 way,Enclosure[607710](Legrand make) Make:-Havells/L&T/Standard/Legrand [Ref:PWD 2017,ELECTRICAL SCHEDULE,CHAPTER D-10,NO-13] [For light,fan socket, A.C point of X-Ray room outgoing]
6Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. 32A DP MCB Isolator(Legrand) [Ref:PWD 2017,ELECTRICAL SCHEDULE,CHAPTER D-5,No 6]
7Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 6-32A SP MCB [Ref:PWD 2017,ELECTRICAL SCHEDULE,CHAPTER D-6,NO-7]
8Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment 4 Way [PWD Schedule Page No-D-9;Iteam No-11] [For X-ray m/c]
9Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection 63A 4 Pole MCB Legrand [Ref:PWD 2017,ELECTRICAL SCHEDULE,CHAPTER D-6,NO-7]
10Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed copper wire(Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI/PVC switch board with top cover plate on wall incl. mending good damages to original finish. [PVC casingcapping and Switch board both on surface] Average run 5 mtr. Ref:Ref:PWD 2017,ELECTRICAL SCHEDULE, CHAPTER E-21,No 1(a)
11Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded FR" PVC insulated & unsheathed copper wire (Brand approved by ElC) in 20mm size PVC rigid conduit "FR" (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded "FR PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by ElIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size "Ph & N" copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. [PWD Schedule Page No-E-24;lteam No-1(a)] on board
12Average run 1.5 mtr.
13Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [Ref:PWD 2017,ELECTRICAL SCHEDULE,CHAPTER E-18,NO-12]
14Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [Ref:PWD 2017,ELECTRICAL SCHEDULE,CHAPTER D-18,NO-9(b)]
15Distribution wiring in 1.1 KV single core stranded "FR" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit "FR" (Precision make) incl. necy. fittings as required 2x 36/0.3 (2.5 sqmm)+ 1x 22/0.3 (1.5 sqmm) ECC Ref:Ref:PWD 2017,ELECTRICAL SCHEDULE, CHAPTER E-9,No 1(s) [Connection from MCBDB to respective Switch Board]
16Distribution wiring in 1.1 KV single core stranded "FR" PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit "FR" (Precision make) incl. necy. fittings as required (iv) 2 x 36/0.3 (6 sqmm) + 1 x 22/0.3 (4 sqmm) ECC [Ref:PWD 2017,ELECTRICAL SCHEDULE,CHAPTER E-14,NO-1(a) [For SPN DB Supply,AC connection & 16A power shocket]
17Supplying & Delivery at site LED batten Tube light fitting [Ordering Code-LHEXARP7SN1w020] Make: Havells/Philips/Bajaj/Crompton. Ref: Havells latest price list 1st June 2022,Page No-22
18Fixing only Single/twin fluorescent light fitting complete with all accessories directly on wall/Celling by screws etc. [Page C-2, It. No. 14(a)]
19Supply of LED Bulb 9 Watt(Havells make,Ordering code-LHLDDBEBB18RO09, or equivalent model of Philips/Bajaj/Crompton) Ref:Havells latest price list 1st june 2022,Page No-46
20Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling. [Ref:PWD 2017,ELECTRICAL SCHEDULE,CHAPTER D-13,NO-22]
21Fixing only 9 W LED lamp [Ref:PWD 2017,ELECTRICAL SCHEDULE,CHAPTER C-2,NO-11]
22Supply and delivery of Ceilling fan 48” Sweep a) Crompton Greaves make [UD & MA page- 23 item no-70]
23Fixing only Ceiling Fan Complete with Blades .Regulator ,Canopy ,Fort Rubber Bush etc. Incl. S & F. 1/1.40 PBC Standered wire & making necessary connection as refquired by 2x1.5 sqmm flexible copper wire [Ref:PWD 2017,ELECTRICAL SCHEDULE,CHAPTER C-3,NO-21(a)
24Supply & Fixing 60 Wt. Electronics Step-Socket type fan regulator (Anchor Make) on switch board after cutting Bakelite tip cover as per direction of EIC [Ref:PWD 2017,ELECTRICAL SCHEDULE,CHAPTER E-6,NO-18(b)]
25Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board. Ref:PwD 2017,ELECTRICAL SCHEDULE, CHAPTER D-13, No-20(a)
26Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C- Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [Ref:PWD 2017,ELECTRICAL SCHEDULE,CHAPTER D-19,NO-17]
27Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [PWD Schedule Page No-E-17 No-5(a)] [For AC & UPS Supply]
28Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe [Ref:PWD 2017,ELECTRICAL SCHEDULE,CHAPTER G-1,NO-2(a)]
29Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [Ref:PWD 2017,ELECTRICAL SCHEDULE,CHAPTER G-2,NO-4(b)]
30Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages (v) No. 8 SWG [Ref:PWD 2017,ELECTRICAL SCHEDULE,CHAPTER G-2,NO-5(a)(v)]
31Supplying of 1.1 KV. Grade PVC insulated Conductor of following cables (make: Polycab/ Gloster/Havells/) 35 sq mm 4 core [UD & MA Page-11 Item- f(1)] [For X-Ray supply]
32Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 Core 35 sq.mm. [Ref:PWD 2017,ELECTRICAL SCHEDULE,CHAPTER F-4,NO-7(c)]
33Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 4 Core 35 sq.mm. [Ref:PWD 2017,ELECTRICAL SCHEDULE,CHAPTER F-5,NO-8(b)(xv)]
34Supplying of 1.1 KV. Grade PVC insulated Conductor of following cables (make: Polycab/ Gloster/Havells/) 50 sq mm 4 core [UD & MA Page-11 Item- f/1] [For existing supply to proposed BBC]
35Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 Core 50 sq.mm. [Ref:PWD 2017,ELECTRICAL SCHEDULE,CHAPTER F-4,NO-7(c)]
36Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 4 Core 50 sq.mm. [Ref:PWD 2017,ELECTRICAL SCHEDULE,CHAPTER F-5,8(b)]
37Supply of Hi-wall Split 1st charge R-410A gas BEE 3Star rated Inverter type air cooled split Airconditioner with cordless remote,harmetic/semi hermetic rotary type. 2.0TR-3Star [Make-Hitachi/Carrier/Daikin]
38Installation,testing, commissioning of Hi wall split 2.0TR
39Add GST @ 18% Except items no-15 & 17
40Add Cess @ 1%
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail