Department of Higher Education has published Tender For Mes College Nedumkandam Procurement Of Laboratory Equipments To The Chemsitry Lab Using Pd Account. Submission Date for this Tender is 10-02-2023. Alkali Metals Tenders in nedumkandam Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

35946315
Tender For Mes College Nedumkandam Procurement Of Laboratory Equipments To The Chemsitry Lab Using Pd Account
Open Tender
Indian
Kerala
nedumkandam
10-02-2023

Tender Details

Tender For MES College Nedumkandam Procurement of Laboratory Equipments to the Chemsitry Lab using PD Account - Laying And Jointing Pvc Pipe. Heading , Table Top Abbe Refractometer -2 No – Rs. 35000 / - Per Unit Measurement Ranges Refractive Index - 1.300 - 1.700 Nd Sugar Content 0- 95% Resolution Refractive Index- 0.0002 Nd Sugar Content - 0.25 % Accuracy Refractive Index - ± 0.0002 Nd Sugar Content - ± 0.25 % Light Source - Led ( Approximating To Wavelength Of D-Line ) , Magnetic Stirrer With Hot Plate-1No – Rs. 30000 / - Per Unit Even Heat Distribution On Surface Of Top High Magnetic Strength Thermal Insulation For Cool Body Operation Speed Range : ~2000 Rpm Temperature Range : Ambient To 550°C Adjustable Safety Cut Off , Water Double Distillation Unit – 1 No. – Rs. 105000 / - Per Unit Capacity: 4Ltr / Hr Electrical Power: 220 / 240 V, 50 / 60Hz, Single Phase Supply. Rust Free Stand Automatic Operation Based On Water Level Distillate Temperature - 25 To 45°C Replaceable Silica Heaterin- Built Safety Cut Off Pressure Temperature Switch ( Pts ) , Benchtop Ph Meter- 2 No- Rs. 40000 / - Per Unit Phrange : -2.000~20.000Ph Phaccuracy: ±0.002Ph Phresolution: 0.001, 0.01, 0.1Ph ( Selectable ) Mvrange : ±1999Mv Mvaccuracy : ±0.2Mv Mvresolution: 0.1, 1Mv ( Selectable ) Calibration: Upto5points Temp.Range: 0~105°C, 32~221°F Temp.Accuracy: ±0.5°C, ±0.9°F Temperaturecompensation: 0~100°C, 32~212°F, Automaticormanual Powersupply:Usingac220v / 50Hz , Digitalphotocolorimeter-2 No- Rs. 13000 / - Per Unit 1Mlsamplevolume Rangefrom 400To700nm Highlystable&Accurate High Standard Glass Filters- 400 450 490 520540 570 620 680 Nm , Flame Photometer – 1 No.- Rs. 125000 / - Per Unit Determination Up-To Five Elements With Single Aspiration Calibration Standard Up-To Five Point. Auto Ignition And Auto Gas Cut-Off Gas Leak Sensor Online Reading Facility Sample Volume: Approx. 3Ml Aspiration Time: Five Element Analysis Within 20 Second On Single Aspiration Elements To Be Detected: K, Na, Li, Ca , Table Top Digital Potentiometer-2 No – Rs. 15000 / - Per Unit Potentiometer Range 0 – ± 199.9 Mv, 0 – ± 1999Mv Resolution : 1 Mv Repeatability : ± 1 Mv Accuracy : ± 1 Mv, ± 1 Digit Input Impedancy : >1012 Ohms Operating Temperature : 10 To 50Oc Digital Display With Auto Polarity Indication Electrodes: Platinum Electrode, Reference Electrode, Glass Electrode And Silver Electrode , Polarimeter-1 No – Rs. 50000 / - Per Unit Measuring Range: ( -180 ) °C To 180 °C Scale Value: 1° Magnifier: 3X Wavelength:589 Nm Light Source: Sodium Lamp ( Built-In ) Test Tube Length: 50 / 100 / 200 Mm , Uv-Vis Spectrometer- 1 No.–Rs. 360000 / - Per Unit Measuring Range: 300-800 Nm No. Of Beams: Double Beam Spectrophometer Sampling: Solid And Liquid Absorbance Accuracy: ±0.005 Photometric Repeatability: ±0.002 Abs At 1 Abs Wavelength Resolution : 0.1Nm Spectral Bandwidth ( Sbw ) : 1 Nm Photometric Range: -3~3 Abs Baseline Stability: 0.002 Abs / Hour Baseline Flatness: + / -0.002 Abs ( 300 - 800 Nm ) Stray Light: =0.05% T At 220Nm And 340 Nm

Key Value

Document Fees
INR 2000 /-
EMD
INR 10000.0 /-
Tender Value
INR 10 Lakhs /-

BOQ Items

Name of Work: MES College Nedumkandam Procurement of Laboratory Equipments to the Chemsitry Lab using PD Account
Sl. No. Item Description
1Laying and Jointing PVC Pipe. Heading
2Table top Abbe Refractometer -2 No – Rs. 35000/- per unit Measurement ranges Refractive index - 1.300 - 1.700 nD Sugar content 0- 95% Resolution Refractive index- 0.0002 nD Sugar content - 0.25 % Accuracy Refractive index - ± 0.0002 nD Sugar content - ± 0.25 % Light Source - LED (Approximating to wavelength of D-Line)
3Magnetic Stirrer With Hot Plate-1No – Rs. 30000/- per unit Even heat distribution on surface of Top High Magnetic strength Thermal insulation for cool body operation Speed Range : ~2000 RPM Temperature Range : Ambient to 550°C Adjustable safety cut off
4Water Double Distillation Unit – 1 No. – Rs. 105000/- per unit Capacity: 4LTR/Hr Electrical Power: 220/240 V, 50/60Hz, Single Phase Supply. Rust free stand Automatic operation based on water level Distillate temperature - 25 to 45°C Replaceable Silica HeaterIn- built Safety Cut Off Pressure Temperature Switch (PTS)
5Benchtop pH Meter- 2 No- Rs. 40000/- per unit pHRange : -2.000~20.000pH pHAccuracy: ±0.002pH pHResolution: 0.001,0.01,0.1pH(Selectable) mVRange : ±1999mV mVAccuracy : ±0.2mV mVResolution: 0.1,1mV(Selectable) Calibration: upto5points Temp.Range: 0~105°C,32~221°F Temp.Accuracy: ±0.5°C,±0.9°F TemperatureCompensation: 0~100°C,32~212°F,AutomaticorManual PowerSupply:usingAC220V/50Hz
6DigitalPhotoColorimeter-2 No- Rs. 13000/- per unit 1mlsamplevolume Rangefrom 400to700nm HighlyStable&Accurate High standard glass filters- 400 450 490 520540 570 620 680 nm
7Flame Photometer – 1 No.- Rs. 125000/- per unit Determination up-to five elements with single aspiration Calibration standard up-to five point. Auto Ignition and Auto Gas cut-off Gas leak sensor Online reading facility Sample volume: Approx. 3ml Aspiration Time: five element analysis within 20 second on single Aspiration Elements to be detected: K, Na, Li, Ca
8Table top Digital Potentiometer-2 No – Rs. 15000/- per unit Potentiometer Range 0 – ± 199.9 mV, 0 – ± 1999mV Resolution : 1 mV Repeatability : ± 1 mV Accuracy : ± 1 mV, ± 1 digit Input Impedancy : >1012 ohms Operating Temperature : 10 to 50oC Digital display with auto polarity indication Electrodes: Platinum Electrode, Reference Electrode, Glass Electrode and Silver Electrode
9Polarimeter-1 No – Rs. 50000/- per unit Measuring range: (-180) °C to 180 °C Scale value: 1° Magnifier: 3X Wavelength:589 nm Light source: Sodium lamp (built-in) Test tube length: 50 / 100 / 200 mm
10Uv-Vis Spectrometer- 1 No.–Rs. 360000/- per unit Measuring Range: 300-800 nm No. of beams: Double beam spectrophometer Sampling: Solid and liquid Absorbance accuracy: ±0.005 Photometric Repeatability: ±0.002 Abs at 1 Abs Wavelength resolution : 0.1nm Spectral bandwidth (SBW): 1 nm Photometric range: -3~3 Abs Baseline stability: 0.002 Abs/hour Baseline flatness: +/-0.002 Abs (300 - 800 nm) Stray light: =0.05% T AT 220nm and 340 nm