| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 14-02-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 21-02-2023 |
| Sl. No. | Item Description |
| 1 | Surface dressing not exceeding 15 cm deep in Hard/Dense soil complete all as specified and as directed. |
| 2 | Excavationin trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth;for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 Sqm on plan and not exceeding 1.5 M in depth and gettingout in hand/dense soilcomplete all as specified and as directed by Engineer in Charge. |
| 3 | All as per item No 02 hereinbefore but in hard rock. |
| 4 | M&L for Cement conc 1:5:10 Type E2 as in mass conc/ filling etc complete all asspecified and as directed byEngineer in charge. |
| 5 | M & L for brick workusing sub class ‘B’ bricks straightor curved on plan exceeding6 Mtr mean radiusbuilt in cementmortar 1:6 for stagingof water tanksand parapet wallcomplete all as specified and directed by Engineer in charge. |
| 6 | M&L for providing cement concrete 1:2:4 Type B1 using 20mm graded stone aggregate as in lintels upto 1.5M clear span , cills , steps, seismic and other similar bands , plinth courses , string courses , lacing courses, parapets and railings upto 60cm in height , copings, kneelers, apex stones, bed plates, water troughs and the like including weathering , slightly roundedor chamfered angles and throating including form work complete all as specified and directed by Engineer in charge. |
| 7 | M&L for providing reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as in foundations including rafts, column footings, plinth beams, etc complete all as specified and as directed |
| 8 | M&L for providing reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as inSlabs supported on walls,beams and columns in floors,roofs, etc complete all as specified and as directed |
| 9 | M&L for providing reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as in columns, pillars, piers, posts and struts etc complete all as specified and as directed |
| 10 | M&L for providing reinforced cement concrete (M-25) Design Mix using 20 mm graded stone aggregates as in Beams, cantilevers, bressummers, lintel over 1.5 span complete all as specified |
| 11 | All as per item No 10here in before but as in chajjas, complete all as specified. |
| 12 | M&L for Use and waste of form work to soffits of suspended slabs such as roof slabs floor slabs landings and similar work not exceeding 200mm thick horizontal orsloping for fair finished surfaces of concrete complete all as specified and directed by Engineer in charge. |
| 13 | M&L for Use and waste of form work to chullah hoods , chajjas trough and similar items incl edges complete all as specified and directed by Engineer in charge. |
| 14 | M&L for Use and waste of form work to sides and soffits of floor or roof beams , beam haunchings , girders bressummers , lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etccomplete all as specified and directed by Engineer in charge. |
| 15 | M&L for Use and waste of form work to sides of conc foundations,footing,bases of columns,raft beams,sides and soffits of plinth beams and similiar worksetccomplete all as specified and directed by Engineer in charge. |
| 16 | M&L for Use & waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floors and roofs n exc 20cm wideand sides of RCC/ PCC bends in walls, horizontal orsloping and similar work exceeding 10cm but n exc 20cm wide for fair finished surfaces complete all as specified and as directed by Engineer in Charge. |
| 17 | M&L for Use & waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floors and roofs and sides of RCC/ PCC bends in walls, horizontal orsloping and similar work exceeding 5cm but n exc 10cm wide for fair finished surfaces complete all as specified and as directed by Engineer in Charge. |
| 18 | M&L for providing cement plaster 15 mm thick in cement mortar 1:4 using water proofing compound as in bearing plaster under RCC slabs complete all as specified and as directed by Engineer in Charge. |
| 19 | M&L for MSTMT bars 10mm dia and over. Cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire ( annealed ) not less than 0.9mm dia or securing with clips complete all as specified and as directed by Engineer in Charge. |
| 20 | All as per Item No 19 here in before but 6 to 8mm dia size, complete all as specified. |
| 21 | All as per Item No 19 here in before but 6 mm dia and over up to 10mm dia as in stirrupsetc complete all as specified and as directed . |
| 22 | Supply on water proofing compound complete all as specified and as directed by the Engineer in Charge. |
| 23 | S & F PVC (SWR) rain water pipe 110mm outer diameter, singlesocketed in any length fixed to walls complete all as specified and directedby Engineer in Charge. |
| 24 | S&F PVC (SWR) bends any radius 110 mm dia fixed to PVC pipes complete all as specified and directedby Engineer in Charge. |
| 25 | M & L for first quality coloured glazed ceramic tiles, fixed in pattern of different colour including borderof high lighter concept frommake:- Somani/Kajaria/Johnsons or as approved by GE of size 300x 450 x 7mm thick as in vertical surfaces such as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match with colour of tiles laid over and including 10 mm thick rendering in cement mortar (1:3), including pointing in white cement with pigment to match the shade of tiles, complete all as specified and as directedby Engineer in Charge. |
| 26 | M&L for Machine cut Kota stone slab flooring 20 mm thick in slabs of size as approved by GE over 20mm thick cement screed basein CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all asspecified and directed byEngineer in charge. |
| 27 | All as per item No 26 hereinbefore in skirtings etc laid over 10mm thick rendering in CM 1:4 complete all asspecified and directed byEngineer in charge. |
| 28 | M & L for 15 mm thick cementplasterin cement mortar 1:4 on brickwork or concretesurfacesfinishedeven and smooth without usingextra cement complete all as specified and directed by Engineer in charge. |
| 29 | M & L for 15 mm thick cementplasterin cement mortar 1:6 on brickwork or concretesurfacesfinishedeven and smooth without usingextra cement complete all as specified and directed by Engineer in charge. |
| 30 | M & L for 10 mm thick cementplasterin cement mortar 1:4 as on ceiling surfacesfinishedeven and smooth without usingextra cement complete all as specified and directed by Engineer in charge. |
| 31 | M&L for Machine cut Granite stoneslab 20-25mm thick black fixed on shelves top or on counters over 20mm thick cement screed basein CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all asspecified and directed byEngineer in charge. |
| 32 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all asspecified and directed byEngineer in charge. |
| 33 | Removing surplus excavated materials (soft/loose soil) to a distance not exceeding 50 metre and depositing where directed at a level not exc 1.5 metres above the starting point complete all as specified and as directed by Engineer-in-Charge. |
| 34 | M&L for Preparation of new plastered surfaces and applying two coats of white lime washing on ceiling surfacescomplete all as specified and as directed by Engineer-in-Charge. |
| 35 | Material and labour for preparation of new decorated surface of walls including applying cement based wall care putty (Birla care/JK wall putty) 1mm thick(average)and applying two coatsof exterior emulsion (any colour) paint over a coat of primer of same manufacturer to achieve uniform and smooth surface using roller brush complete all as per manufactures instructions and directed. |
| 36 | M&L for Preparation of new plastered surfaces and applying two coats of oil emulsion distemper on walls including chalk whitening preparatory to distempering and a priming coat of alkali resistant primer complete all as specified and as directed by Engineer-in-Charge. |
| 37 | Material and labour for PCC (1:3:6) (20mm graded aggregate 75mm thick as in plinth protection surface finished even and fair without using extra cement including joints filled with bitumen mastic complete all as specified and directed by Engr-in-charge. |
| 38 | M&L for 100 mm thick cement concrete (1:4:8) type D-2 with using 40 mm graded stone aggregates) asin sub base of flooing etc complete all as specified and as directed. |
| 39 | M&L for sand filling under floor or in foundations including watering and consolidation complete all as specified and as directed . |
| 40 | M&L for cement concrete 1:2:4 type, B1 using 20 mm graded stone aggregates as in copings including necessary fromwork, weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed . |
| 41 | S&F powder coated colouredaluminium anodized door frame and fully glazed shutterdivided in to two glazed panels including aluminium anodized snap beadingand rubber gasket / lining for fixing of glass as directed. The frame shall be fixed with aluminium anodized bolt by drilling in the existing wall and with thrust bolt of suitable sizeall as directed. The frame and shutter will be made out of the following sections and fittings: (a) Aluminium anodized door frame 100mmx44mmx1.6mm fixed with aluminium board and thurst bolt in walls by drillingas directedAluminium anodized top, sides and lock rails of shutter section 81mmx44mmx1.6mm(b) Aluminium anodized bottom rail of shutter section 112mmx44mmx1.6mm(c) Brass six lever dead lock suitable for aluminium doors manufactured by Harrison Locks or Godrej as approved – 01 No for each door(d) Aluminium anodized tower bolt 200mmlong size Make Classic or Argent – 02 No in each door(e) Aluminium anodized fancy handle 250mm long Make Classic or Argent – 02 No in each door(f) Glass pane shall be 5.5mm thick tinted glass/ black plain glass of size as required(g) Floor spring hydraulic heavy duty and pivot arm Make Everite/ Sandhu – 01 No for each door complete all as specified and as directed . |
| 42 | S&F powder coated coloured Aluminium anodized window frame 100mmx44mmx1.6mm fixed with aluminium board and thurst bolt in walls by drillingas directed.(a) Aluminium anodized window shutter styles and rails 44mmx44mmx1.6mm (b) Aluminium anodized butt hinges 04 Nos in each window 75mm long ISI marked (c) Aluminium anodized tower bolt 200mmlong size Make Classic or Argent – 02 No in each shutter (d) Aluminium anodized cast type handles Make Classic or Argent – 01 No in each shutter(e) Aluminium anodized hook and eye 150mm long 01 no for each shutterblack Glass pane shall be 5.5mm thick tinted /plain glass of size as required complete all as specified and as directed . |
| 43 | S&F powder coated colouredaluminium anodized fixed partition fully glazeddivided in toglazed panels not exceeding 900mm centers both ways including aluminium anodized snap beadingand rubber gasket / lining for fixing of glass as directed. The frame shall be fixed with aluminium anodized bolt by drilling in the existing wall and floor with thrust bolt of suitable sizeall as directed. The frame of partition shall be made out of the following sections and fittings: (a)Aluminium anodizedframe 63mmx38mmx1.6mm fixed with aluminium board and thurst bolt in walls by drillingas directed. (b) Panels shall be of 12mmthick pre laminated particle board bothside decorative or Black glass Make Novopan/ Kitlam/ Bhutan Board complete all as specified and as directed . |
| 44 | S&F false ceiling with exposed GI system using “SILHOUETTE XL 15 mm (Nominal) designer Grid \"Armstrong\"white or Global white with black reveal and 600 x 600 x 15 mm thick prime fine fissured micro look white/coloured tiles (superfine 15mm/silhouette). Making necessary framework for AC ducting, if any and necessary cutouts for diffusers and light fittings, taping and finishing to proper line & levelcomplete all as per manufacturer’s instructions and as directed. |
| 45 | M & L for vitrifiedceramictiles double charged10 mm thick (square/rectangular) area of each tile exceeding 0.36 but not exceeding 0.42 sqm in foor etc,set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade over and including 15 mm thick cement screed bed in CM 1:4 complete all as specified and as directed. |
| 46 | All as per item No 45 above but in skirting/risers/dados etc.over and including 10 mm thick rendering in CM 1:3 complete all as specified and as directed. |
| 47 | M & L forpreparation and cleaned to plastered/concrete surfaces of roof applying the under mentioned course ofroof treatment as given below :- (a) Applying evenly compactible primer @ 0.4 litre per Sqmtr overconcrete/plastered roof surfaces.(b) Applying a tack coat of industrial bitumen @ 85/25 grade (ISI marked) @ 1.2 kg/Sqmtr.(c) Laying of membrane sheet of weight not less than 3.6 kg/Sq.mtr with minimum longitudinal end over laps of 100mm and horizontal side laps of 75mm and joints finally thermo-fused with help of LPG flames. Membrane sheet laid over a tack of industrial bitumen 85/25 as specified here-in before. Note : --(i) Membrane sheet also laid along the parapet upto 30cm height & inserted inside the groove & laid over a coat of bitumen as specified here-in-before.The groove shall be closed with CM (1:3 ) mortar Nothing extra shall be admissible on this account (ii) WPC shall be measured & paid underpecified item of this Schedule. Nothing shall be entertained on this account. (iii)Contractor shall submit guarantee for 10 years from the date of completion of work. (iv) The amount against guarantee period for roof treatment shall be retained from the contractor due’s or contractor may furnish a fixed deposit receipt in favour of GE as issued by Nationalize Bank. (v) Amount of security deposit against the guarantee period for roof treatment shall be calculated as per the scales laid down for calculating Individual Security from total amount of roof treatment. |
| 48 | S&F 1.25mm thick Steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer and two coat of synthetic enamel paint; erected in position as indicated, gear operated type with bevel gear box and crank handle complete,, all as specified and directed. |
| 49 | M & L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation etc complete all as specified and directed. |
| 50 | M & L for brick work with sub class \"B\" bricks straight or curved on plan exc 6 m mean radius build in CM 1:4 complete all as specified and as directed. |
| 51 | M&L for Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and as directed. |
| 52 | M&L for Precast RCC slab in RCC 1:2:4 and set in cement mortar 1:4as in lintel complete all as specified and as directed. |
| 53 | Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing)removing serviceable tiles to store and rubbish off the permises complete all as specified and as directed. |
| 54 | S&F joint free anti skid printed and coloured ceramic tiles area of each tiles exceeding 0.06sqm but not exceeding0.11 Sqm and 7mm thick as in floor set &jointed in neat cement slurry & pointed in coloured cement to match over 15mm thick screed in cement mortar 1:6 complete all as specified and as directed. |
| 55 | S & F 15mm dia tubes medium grade, galvanized, with all fittings such as sockets, bends, elbows, tees etc, concealed/surface fixed to walls and ceiling or laid in floors complete all as specified and directed. |
| 56 | S & F 20 mm dia tubes medium grade, galvanized, with all fittings such as sockets, bends, elbows, tees etc, concealed/surface fixed to walls and ceiling or laid in floors complete all as specified and directed. |
| 57 | Supply and fixPVC (SWR) floor trap with dia of outlet75mm, with CP gratingwith hinge in kitchen and bath etcsituation including PCC 1:2:4 type B1 for setting the trap and jointing to waste pipe including taking out old floor trap , complete all as specified and directed. |
| 58 | Material and labour for, 75mm dia PVC (SWR) pipes single socketed, in any length with or without ears, including cement jointing, laid in trenches or or walls, complete all as specified and directed. |
| 59 | S & F 75mm bore PVC (SWR) bends, diminishing pieces or tapers all as specified and directed. |
| 60 | S&Fstainless steel 150mm x 150mm x 100mm floor trap grating ( anti cokcroach)jointing with solvent complete all as specified and as directed. |
| 61 | S&F20mm dia gun metal gate valve, with iron wheel head, screwed both ends for iron pipes complete all as directed by Engr in Charge. |
| 62 | S&F PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 63 | S&F factory made 18mm-19mm thick plain PVC foam board of density 600kg/cum for Shelf / Partitions / Drawer Complete all as specified and directed. |
| 64 | Supply & fixing 1mm thick Matt finish acrylic Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer\"s instruction complete all as specified and directed. |
| 65 | S&F 100 mm size Stainless Steelhandle, complete all as specified and as directed. |
| 66 | S&F stainless steel 110 degree hinges for cupboard complete all as specified and as directed. |
| 67 | M &L forABS body magnetic latches of size 50mm complete all as specified and as directed. |
| 68 | S&Fvitreous china colouredOne piece EWCs with integrated cistern, seat cover and twin flush fittings and including P or S trapetc. all as spfd and complete all as specified and as directed.( Cat part CARVEL of Cera or Equivalent ) |
| 69 | S&Fvitreous china colouredurinal with backside inlet for water including Sensor Concealed Type Flushing Valve for Urinal Complete Set with Installation Box with Control Cock (Battery Operated)complete all as specified and as directed.( Cat part URS-WHT-13253Oand SNR-STL-51087 of Jaquar or Equivalent ) |
| 70 | Supply and fixcounter top oval shape ivory/white coloured wash hand basin of size 56 x 41cmmake- CNS-WHT-903 of Jaquar or Equivalent complete all as specified and as directed. |
| 71 | S&F 32mm dia medium grade galvanising steel water tubing isi marked with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and as directed. |
| 72 | Supply and fixCP paper holderof Make-AHS-1553 of Jaquar or equivalent. complete all as specified and directed. |
| 73 | Supply and fix15 mm angle valve chromium platedand fancy typewith crutch or butter fly handle high pressure screwed down complete all as specified and as directed. Make- ORM-10053 of Jaquar or Equivalent. |
| 74 | Supply and fixCP waste coupling 32mm size half threaded with 130mm height complete all as specified and as directed. Make-ALD-709 of Jaquar or equivalent |
| 75 | Supply and fixCP bottle trap with internal partition32mm size 300 mm x 190 mm with wall connection pipe and wall flange complete all as specified and as directed.Make-ALD-769 L of Jaquar or equivalent |
| 76 | Supply and fix 15 mm bore bib taps chromium platedand fancy typewith crutch or butter fly handle high pressure screwed down complete all as specified and as directed. Make- ORM-10037of Jaquar or Equivalent. |
| 77 | Supply and fixCPsingle lever basin mixer with popup waste system and 450 mm long braided hoses chromium platedcomplete all as specified and as directed. Make- ORM-10051 B of Jaquar or Equivalent. |
| 78 | S&Ffancy type frame less designer looking mirror of selected quality glass (Approx size 900 x450x 8mm )and fixedwith 4 nos SS studs of suitable size complete all as specified and directed. |
| 79 | S&F 8mm thick Rectangular shaped 900mmx 450mm urinal partition with frosted glass fixed with stainless steel bracket as recommended by manufacture complete all as specied and directed. |
| 80 | Taking down chowkats or frames with shutters (with out taking off shutters from the frame) not exceeding 1.50 Sqm each all as specified and directed . |
| 81 | Taking down chowkhats or frames with shutters without taking off shutters from the frame exceeding 1.5 Sqm but not exceeding 4 Sqm each andall as specified and directed. |
| 82 | M&L for Factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded coloured PVC ’C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and single sideprelaminated PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of single sideprelaminated PVC sheet to be fitted in the MS frame welded/ sealed into the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying andfixing in the frame at site as per specification complete all as specified and as directed. |
| 83 | S&F Factory made PVC solid door frame of size 50 mm x 47 mm with wall thickness of 5 mm made out of5 mm thick plain colour PVC sheet cut at corner and jointed with 02 Nos., 150 mm long brackets of size 15 mm x 15 mm mild steel square tubes 19 gauge including vertical door profiles reinforced with 19 mm x 19 mm steel square tube of 19 gauge (EPDM) rubber gasket weather seal provided throughout the frame and fixed to wall with 65/100 mm long mild steel screws through the frame by using PVC fasteners (minimum of 04 Nos. of screws to be provided for each vertical member & minimum 02 Nos. for horizontal member), complete all as specified. |
| 84 | S & F SS butt hinges, medium weight100mm size all as specified and directed by Engineer - in - Charge . |
| 85 | S & F 200mm longStainlesssteel tower bolts all as specified and directed . |
| 86 | S & F Stainless steel sliding door, bolts, not less than 12mm bore, length of bolt 250mm all as specified and directed. |
| 87 | S & F stainless steelhandles oval type, 125 mm size all as specified and directed . |
| 88 | S&F powder coated aluminium frame work fordoors, windows,partition s etc incl grill for windows for windows etc with one or more rebated section incl jointing cleats for fixingetc complete all as specified and as directed. |
| 89 | S&F powder coated anodised aluminium door shutters, partition wall, aluminium section weighting 0.55 Kg/Rm incl necessary joining cleats glazing clips rubber neoprene packing, handles two Nos in each door, hinges anodised aluminium snap beading screws etc complete all as specified and as directed. |
| 90 | S&F powder coated anodised aluminium window and ventilator shutters , side hung type without sash bars aluminium section weighting 0.55 Kg/Rm incl necessary joining cleats glazing clips rubberpacking, aluminium anodised snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (1Nos0, hinges type B-21 100 mm long(2Nos) suitable handles (1Nos)complete all as specified and as directed. |
| 91 | S&F 12mm thick prelaminated board, exterior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination fixed with screws to aluminium frame work complete.all as specified and directed by Engineer - in - Charge . |
| 92 | S&F 5.5 mm thick selected quality tinted sheet glass and glazing clip in square fixed with PVC/neoprene gasket in aluminium frame work compelte. all as specified and directed by Engineer - in - Charge . |
| 93 | S&F double action floor spring hydraulic regulated made up of min 1.25 mm thick aluminium sheet foundation box, main body with stainless steel cover, govering pivets made of brass, other part made up of mild steel heavy duty complete. all as specified and directed by Engineer - in - Charge . |
| 94 | S&Fbrass six lever dead lock suitable for aluminium doors manufactured by Harrison Locks or Godrej as approved complete all as specified and as directed. |
| 95 | S&F Joist, channel, angle, or tee sections etc.with Fe-290 (Gde E165) quality A complete all as specified and as directed. |
| 96 | M&L for Pre-painted galvalume aluminum zinc coating GI based corrugatedsteel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screwsallas specified and as directed. |
| 97 | Demolition ofwall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets/board fixed in aluminium door or partition, any thickness, including cover fillets & framed work if necessary complete all as specifiedand directed. |
| 98 | M & Lforcutting in to existing manhole for connecting new drains, making good to pipe and rendrering, cutting out existing benching for and forming branch chammel ( 1/2round or 3/4 section) in cement concrete1:2:4 type B-1 smooth finished, and reforming benching as required completeallasspeifiedand directed. |
| 99 | Dismentling of Bricks laid dry(laid flat or on edge) or brick tiles in floors, roof , channels, kerbs, aprons, etc. (each layer), complete all as specified and as directed. |
| 100 | Demolition of Mud Phuska in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) disposing the rubbish to a distance exceeding 250 Mtr but not exceeding 500 Mtr away to low lying areas complete all as specified and directed. |
| 101 | M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in floor finishing, copings, roof padding, staging of water tank, benching etc and similar nature of worksincluding finishing even and smooth using extra cement and rounded or chamfered on edges and necessary foamwork complete all as specified and directed by Engineer-in-Charge. (i) Ratesinclude to carried out the work on roof slab of building & nothing extra shall be admissible on this account). |
| 102 | M&L for 15 mm thick plaster in CM (1:4) mixed with water proofing compound on roof slabs finished even and smooth without using extra cement after complete removal of exisitng APP membrane/ cleaning of roof surfaces with wire brushes complete all as specified and directed by Engr-in-Charge. |
| 103 | M&L for applying evenly 3 coat of elastomeric liquid applied membrane of Home Shield PU roofkoat of Berger or equalvent as approved by Engrineer-In-Charge as in Roof portion including preparing of surface by removing existing treatment complete all as specified and as directed by approved applicater.Note :- Authorised applicater is approved by GE. |
| 104 | Dismantling damaged/unserviceable GI Snap Grid Ceiling Frame Work with Ceiling Boards of any description, complete all as specified and as directed. |
| 105 | S&F GI Powder coated GI Snap Grid Frame Work of size 605x605mm as in False Ceiling with supported hanging of Mild Steel Rod of\"J\" Bolt, complete all as specified and as directed. |
| 106 | S & F in repairs4 mm thick designer Fibre cement board ( E-board) Tile of size 595x595 mm of approved texture, blossom, fixture and primerfinished complete , complete all as specified and as directed.Note : Weight not less than 4.84 Kg /m2Make : Everest or Equivalent. |
| 107 | Taking down old point wiring complete for light/fan/socket(5/15 Amps) bell point etc complete with all light fittings accessories, such as switch sockets 5/15 Amps ceiling rose etc including making good to the disturbed surface to match with the existing complete all as specified and directed by Engineer-in-Charge. |
| 108 | M&L for concealed point wiring for the following the PVC insulated and unsheathed cable 1.5 sq mm (nominal area) multistranded copper conductor 1100 v FRLS grade single core including PVC conduit medium grade of appropriate size (not less than 25 mm dia) ISI marked concealed in wall and surface on ceiling complete with all accessories and all as specified including 1.5 sq mm PVC insulated unsheather multistranded copper conductor to common earth and connected to earth dolly for following :- (Note) : 1.The cuttingchases shall be finished with cement mortar (1:4) and surface shall be matched with existing surface by using putty, POP etc and applying finishing coat of existing treatment without any extra cost.2. Rate quoted by the contractor deemed to be included metal flush box of suitable size as required at site and 3 mm thick laminated sheet suitable for mounting of switch and socket etc . |
| 109 | One light point control by one switch |
| 110 | One ceiling fan/exhaust fan control by one switch |
| 111 | One 3 pin socket outlet, 5 Amps independent |
| 112 | One 3 pin 5 amps socket outlet on the same board with other switches |
| 113 | All as per item No. 108 above but wire 4.0sq mm cable for switch socket outlet 3 pin 15 Amps with 4.0 sq mm as earth continuity conductor. (FOR geyser/AC point) |
| 114 | All as per item No. 108 above but wire 4.0 sq mm cable for switch socket outlet 3 pin 15 Amps with 4.0 sq mm as earth continuity conductor. (For Geyser point) |
| 115 | S&F in replacement socket outlet 6A-2/3 Pin combined 2 module modular type complete all as specified and directed. Make : Havells Fabio 2.Carb tree, or its equivalent |
| 116 | S&F in replacement socket outlet 6A/16A-2/3 pin combined 2 module modular type complete all as specified and directed. Make : Havells Fabio 2.Carb tree, or its equivalent |
| 117 | S&F in replacement switch 6 amps modular type one one way complete all as directed.Make : Havells Fabio 2.Carb tree, or its equivalent |
| 118 | S&F in replacement switch 16 amps modular type one one way complete all as directed. Make : Havells Fabio 2.Carb tree, or its equivalent |
| 119 | S&F in replacement metal flush box 3 module all as specified and directed. |
| 120 | S&F in replacement metal flush box 6 module all as specified and directed. |
| 121 | S&F in replacement metal flush box 8 module all as specified and directed. |
| 122 | S&F in replacement for white cover plate with frame, 3 module all as specified and directed. |
| 123 | S&F in replacement for white cover plate with frame, 6 module all as specified and directed. |
| 124 | S&F in replacement for white cover plate with frame, 8 module all as specified and directed. |
| 125 | Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 126 | Supply and fixing LED tube light fitting mirror type with high output diffuser 2 feet, 10 watts 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 127 | M& L for making hole to the existing wall surface of any type/girth and at any height for fixing of exhaust fan 300 mm sweep and make good to match with the existing surfaces complete all as specified and directed by Engr-in-charge . |
| 128 | Supply and fix heavy duty single phase, steel body exhaust fan 300 mm sweep, 900 RPM complete with shutter and louvers and exhaust fan shall be fixed with suitable size of buzzer bolt/hold fastener as approved by Engr-in-charge complete all as specified and directed. |
| 129 | Supply and fixsingle pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified and directed. |
| 130 | Supply and fixing TPN DB\"s 4 way vertical type 415 V, double door suitable for housing of 125 Amps MCCB as main incoming complete all as specified and as directed. |
| 131 | Supply and fixing MCCB 125 Amps, 4 Pole, 16 KA, suitable to be fixed in 4way TPN DB complete all as specified and directed. |
| 132 | S & F in repair MCB DB double doorSPN 12 Way with 200 Amps rated copper bus bar complete all as specified and as directed. |
| 133 | S & F MCB SP 6-32 Amps complete all as specified and as directed. |
| 134 | S & F MCB SP 63 Amps complete all as specified and as directed. |
| 135 | S & F MCB SPN 63 Amps complete all as specified and as directed. |
| 136 | M&L for earthing to switch gear/MCB DB with mild steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to galvanised earth lead wire 4.0 mm diaby means of galvanised iron nuts, bolts and washer, earth lead connected to eqpt as directed, earth plate surrounded with adequate quantity of charcoal dust mixed with common salt to a packed thickness of 15 cm all around the plate including necessary earth work, PCC chamber and reinforced PCC cover made by PCC 1:3:6 type C-1 as in pit chamber and RCC pit cover 50 mm thick precast RCC 1:2:4 type B-1 duly reinforced with 6mm dia MS bar at 150mm c/c both ways with 10 mm dia MS round bar as handle, 20 mm bore GI pipe medium grade for watering and 15 mm dia GI pipe light grade for protection of earth lead up to 7.5 mtr with funnel, wire mesh etc with and including testing complete all as specified and as shown in electrical plate No 3 of MES sch Part I complete all as specified and as directed.. (for TPN DB\"s) |
| 137 | Earthing continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed or any other indicated situation for loop earthing etc.As required 4 mm dia galvanised iron or steel wire. complete all as specified and as directed. |
| 138 | S & F in repair sub main wiring for circuit of size 6 sq mm 2 core (FRLS) alongwith earth wire of 4 sq mm single core of FRLS PVC insulated unsheathed cable,1100 volts grade with multistranded copper conductor including PVC conduit (conealed wiring) of suitable size complete all as specified and directed by Engr-in-Charge. (FOR SPN DB\"s ) |
| 139 | Supply and fixing LED luminaire 600 mm x 600 mm 35/36 watts, 220 Volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases for suitable size complete all as specified and as directed. |
| 140 | Supply and fix electric water heater storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 Ltrs, BEE 5 star rated complete with all accessories such as safety valve, thermostat NRV, connection pice etc. complete all as specified and as directed. |
| 141 | Supply and fixing wall fan 400 mm sweep, 240 Volts, AC, 3 speed, pull cord for speed and oscillaation, aluminium blades for high air thurst complete suitable clamps for wall mounting complete all as specified and directed. |
| 142 | S & F switch piano flush type one way 5 Amps complete all as specified and as directed. |
| 143 | Supply and fix ceiling rose three terminal complete all as specified and as directed. |
| 144 | S & F socket outlet 2 in 1, 3 pin, 5 Amps complete all as specified and as directed. |
| 145 | S&F socket outlet 2 in 1, 3 pin, 5 and 15 Amps flush type complete all as specified and as directed. |
| 146 | S&F switch piano, flush ype single pole 15 Amps complete all as specified and as directed. |
| 147 | Supply and fixinglamp holder, PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. |
| 148 | Supply and fixing LED lamp 10 watts (Twist lamp), 180 degree rotationl movement, 70 degree swivel movement, diffuser for glare free distribution, base cap B22, 1000 lumens complete all as specified and directed. |
| 149 | Supply and fix ceiling fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep.Min air delivery 245 CFM and service value 6.00 BEE.Five star rated with brushless direct current motor (BLDC) of approved colour white/brown/ivory complete three core flexible wire etc from ceiling rose to fan complete all as specified and as directed. |
| 150 | S & F in repair MCB DB double doorSPN 8 Way with 200 Amps rated copper bus bar (One No. of stair case wiring) complete all as specified and as directed. |
| 151 | S & F MCB SPN 40 Amps (for SPN DB 12 and 8 way) complete all as specified and as directed. |
| 152 | S&F RCBO\"s double pole 100 mA for earth leakage, overload & short circuit protection of capacity 40 Amps complete all as specified and as directed. |
| 153 | Supply and fixing LED bldg security light fitting 35 watts 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including suitable size of GI bracket for mouting of security light to be bend as required shape, pipe bracket shall not be less than 1.2 Mtr length and suitable size 02 Nos MS clamps and nuts and bolts complete all as specified and as directed. |
| 154 | S & F sub main wiring for circuit of size 1.5 sq mm 2 core (FRLS) alongwith earth wire of 1.5 sq mm single core of FRLS PVC insulated unsheathed cable,1100 volts grade with multistranded copper conductor including PVC conduit (conealed wiring) of suitable size complete all as specified and directed by Engr-in-Charge. |
| 155 | Supply and laying in repair and testing cable XLPE insulated, screned, PVC bedded galvanized steel strip or wire amoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and as directed. |
| 156 | Excavation in trenches n exc 1.5 wide and n exc 1.5 m in depth for foundation etc or for laying cable etc n exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed. |
| 157 | Returning filling in including spreading, leveling, watering and well ramming in layersexc 25 cm thick complete all as specified and as directed. |
| 158 | Removal of excavated material/surplus soil to a distance n exc 50m and depositing where directed at a level n exc 50m above the starting point complete all as specified and as directed. |
| 159 | Supply and filling river sand in trenches including spreading for cushioning of LT UG cable complete all as specified and as dirceted.Note : Punned down thickness shall be measured and paid . |
| 160 | M&L for sub class ‘B’ bricks old sizelaid flat dry in trenches over cable, across the direction of cable complete all as specified & as directed . |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy