Uttar Pradesh Projects Corporation Limited has published Tender For Construction Of Proposed Dormitory Block, Tourist Information Center, External Development And Redevelopment Of Cottages At Kapilvastu (Piprahawa) Distt. Siddharth Nagar (Up). Submission Date for this Tender is 30-01-2023. Building Work Tenders in Balrampur Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Dormitory Building |
2 | Excavation in foundation in Ordinary soil (loamclay or sand) including lift upto 1.5m. And lead up to 30m. And including filling, watering and ramming of excavated earth into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the E.I.C. up to a distance of 30m. from the foundation trenches including all T&P phowarah and basket etc. complete. |
3 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
4 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8kM from the site of work and including watering dressing etc. Rate to include cost of all materila, labour and T&P etc. required for proper completion of the work. |
5 | Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge. |
6 | Providing & injecting chemical emulsion for Preconstructional anti-termite treatment and creating a chemical barrier under & around the column pits, wall trenches, basement excavation top surface of plinth filling junction of walls & floors,along the external perimeter ofbuilding expansion joints surrounding of pipes & coduits etc. complete plinth area of the building at ground floor only shall be measured as per I.S.6313 (part II 1981) Aldrine emlsifiable concentrate or any other approved material such as Chloropyriphos or Heptrachier or Chlordance will beused. Therateof application ofchemicalemulsionshallbeasfollows: (I) Treatment for masonary & foundation 5litres/ sqm. (II) Back fill in immediate contact with foundation 7.5 litres / sqm (III) Treatment of top surface of plinth filling 5 litres/sqm . (IV) Treatment of junction of wall and floor 7.5litres/sqm. (V) Treatment of soil along external perimeterof building 7.50 litres/sqm. (VI) Treatment of soilunder Apron along external perimeter 5litres/sqm |
7 | Cement concrete with 4 cm guage approvedstone ballast, approved coarse sand and cement in the proportion of 4:2:1 including supply of materials, labour and T&P etc. required for proper completion of the work. |
8 | Same as item 279 above but 2cm guage stone grit. |
9 | Cement concrete with 4cm. Guage approved stone ballast, approved coarse sand and cement in the proportion of 8:4:1 including supply of all materials, labour and T&P etc. required for proper completion for the work. |
10 | Same as item no. 361 but 4cm thick |
11 | painting on DPC with two coats of air blown bitumen 85/50 or 85/25 @ 1.7kg/sqm. Approx. including cost of fuel if any. |
12 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stoneaggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed andonsolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
13 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : |
14 | Foundations, footings, bases of columns, etc. for mass concrete |
15 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
16 | Suspended floors, roofs, landings, balconies and access platform |
17 | Shelves (Cast in situ) |
18 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
19 | Columns, Pillars, Piers, Abutments, Posts and Struts |
20 | Stairs, (excluding landings) except spiral-staircases with water proof ply 12mm thick |
21 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick |
22 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) |
23 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. |
24 | (Note :- Cement content considered in this item is @ 330 kg/ cum.Excess/less cement used as per design mix is payable/recoverable separately). |
25 | All works upto plinth level |
26 | All works above plinth level upto floor V level |
27 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete for proper completion of the work and including supply of steel its wastage.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
28 | M-15 Sub Class (A) Brick work in 1:6 cement and sand of 1.25 fineness modulus mortar in foundation and plinth including supply of all materials, labour, T&P etc. required for proper completion of work. |
29 | As in item 302 to 307 above but in superstructure including necessary cutting and moulding of bricks and also including honey comb brick work, thickness of walls more than one brick and for extra labour to above items. |
30 | As in item no. 309 above but for one brick wall add for extra labour. |
31 | As in item no. 309 above but walls of half brick wall add for extra labour. |
32 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
33 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
34 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood |
35 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
36 | Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge |
37 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
38 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
39 | Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). |
40 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick |
41 | Providing and fixing 6mm thick toughened glass complete in all respects as per direction of the Engineer-in-charge. |
42 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately). |
43 | Roller Blinds:- Providing and fixing Roller Blinds as per the approved sample comprising of screen Fabric comprising of 25% polyester, 75% PVC with openness factor of 5%.Fabric weight 410-465 G weight per sqm, Thickness 0.67 mm. Healthy/safety standard - Oekotex Standard 100.Yarn count 18-19/cm, having fire resistance standard – NFPA 701 Method 1:2004 GB 50222-1995 (B1).The tear resistance should be complying to ISO4674 & breaking resistance – warp: > 1850 N/5cm, Weft: > 1400 N/5cm haing tear resistance of warp: > 135N and Weft: > 105N. Color fastness to Light 6-7/8(ISO 105 B02:1994).The Roller blind system consists of 38mm OD extruded out of Aluminium alloy 6063 T6 with silver anodized to provide an everlasting finish and luster, the rotary unit shall be 36mm in OD incorporating a clutch mechanism composed of low – flexing braided polyester cord with nylon core, Control Ball chain shall be composed of braided nylon cord (2mm dia) with high engineering grade plastic beads of 4.5mm diameter mounted co-axially on the cord with a pitch of 6.2mm (C-T-C) Bottom rail should be powder coated Aluminium flat bottom rail of 290 gm to finish it from the ends it should have rail end caps. The clutch will be at the tube. The return end cap bracket shall incorporate snap spring design to facilitate easy installation and removal for maintenance activities. The bracket shall be finished with a flush mounting cover on each side providing an aesthetic finish. It should handle up to 5 Kgs of material. The clutch should mount flush to the face of the bracket which minimize the light gap between the shade and the window frame. Complete in all respect as per the direction of Architect/Engineer-in-charge. |
44 | Door hardware |
45 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
46 | 250x10 mm |
47 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
48 | 300x16 mm |
49 | Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of 5 mm (± 0.2 mm), made out of single piece extruded PVC profile, with mitred cut joints and joint with 2 nos of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40x20 mm M.S. rectangular tube of 0.8 mm , including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8 x100 mm long anchor fasteners complete, all as per manufacturer"s specification and direction of Engineer -in- charge. |
50 | 35 mm thick factory made Solid panel PVC Door shutter, made out of single piece extruded soild PVC profiles, 5 mm (± 0.2 mm) thick, having styles & rails (except lock rail) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power, including reinforcing with MS tube of size 40 mm X 20 mm x 1 mm, joints of styles & rails to be mitered cut & joint with the help of PVC solvent cement, self driven self tapping screws & M.S. rectangular pipes bracket of size 190 mm X 100 mm of cross section size 35 mm x 17 mm x 1 mm at each corner. Single piece extruded 5 mm thick solid PVC Lock rail of size 115 mm x 35 mm, out of which 75 mm to be flat and 20 mm to be tapered at both ends, having 15 mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125 mm x 11 mm, including providing 5 mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer"s specification and direction of Engineer-in-charge. |
51 | Decorative finish (wood grained finish) |
52 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required in stringers, treads, landings etc. of stair cases, Railing including use of chequered plate wherever required, all complete. |
53 | Providing and fixing 1mm thick M.S. Sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces |
54 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rustfree, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling,C.P. brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) : |
55 | For fixed portion |
56 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
57 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
58 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
59 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
60 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
61 | Filling the gap in between aluminum frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width |
62 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315 , having brand logo embossed on the body/ plate with double spring mechanism and door weight upto 125 Kg., for doors including cost of cutting floors ,embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete. With stainless steel cover plate minimum 1.25 mm thickness |
63 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Wedge expansion type Fastener with threaded dia 12 mm |
64 | Providing and fixing 18 mm thick Granite (gang saw cut), mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high glossy finish etc. complete at all levels. |
65 | Granite stone of any colour and shade |
66 | (a) Slab area upto 0.50 Sqm |
67 | (b) Slab area Above 0.50 Sqm |
68 | Providing and laying rectified Glazed/Matt Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. |
69 | Providing and fixing Ist quality rectified ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
70 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
71 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
72 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
73 | Double charge vitrified tile polished finish of size |
74 | Size of Tile 600 x 600 mm |
75 | Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge |
76 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
77 | Providingedgemouldingto18mmthickGranitestone, includingmachinepolishingtoedgetogivehighgloss finish etc. complete as per design approved by Engineer-in- Charge. Granite Work |
78 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
79 | Note:- All Plaster work will carried out with prevention of surface cracks appearing between junctions of column/beam and walls, 150 mm wide chicken wire mesh should be fixed with U nails 150 mm centre to centre before plastering the junction. The plastering of walls and beam/column in one vertical plane should be carried out in one go. For providing and fixing chicken wire mesh with U nails nothing shall be paid extra. |
80 | 12 mm cement plaster of mix (with fine sand): |
81 | 1:4 (1 cement: 4 fine sand) |
82 | 15 mm cement plaster on rough side of single or half brick wall of mix : (with coarse sand): |
83 | 1:6 (1 cement: 6 coarse sand) |
84 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement: 3 coarse sand) finished rough with sponge. |
85 | 6 mm cement plaster of mix : |
86 | 1:3 (1 cement : 3 fine sand) |
87 | 12 mm cement plaster finished with a floating coat of neat cement of mix : |
88 | 1:4 (1 cement: 4 fine sand) |
89 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
90 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including base perparation with cement based putty & applying additional coats wherever required to achieve even shade and colour. |
91 | Finishing walls with textured exterior paint of required shade New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm including base perparation with cement based putty & applying additional coats wherever required to achieve even shade and colour. |
92 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
93 | Two or more coats on new work |
94 | Stone work, plain in copings, cornices, string courses and plinth courses,upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. |
95 | White sand stone |
96 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: |
97 | (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. |
98 | (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
99 | (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. |
100 | (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. |
101 | (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : |
102 | With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
103 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : |
104 | (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. |
105 | (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
106 | Providing and laying broken AAC Block in sunken portion of W.C. & kitchen. These broken Block mixed with cement mortar 1:8 ( 1 cement : 8 coarse sand) laid and compacted properly including supply of labour, material, and tools and plant etc. as per instruction of Engineer-in-charge. |
107 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
108 | In 75 x75 mm deep chase |
109 | Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. |
110 | INTERNAL ELECTRICAL WIRING |
111 | Wiringpointforlightwith1.5sq.mm.FRLSHPVC insulatedmultistrandsingle core copper conductor cable inheavyguageinPVCconduitpartlyconcealedinthe wallandpartlylaidinslabalongwiththereinforcement beforeconcreting,completewith 1.5 sq.mmFRLSH PVC insulated multistrand copper conductorearth continuity wire drawn inside,GP Box, Modular type switch&ceilingrose/angle/battenholderon3mmthick phenolicpaminatedbackalitesheetetccompleteinall respect as directed including matching colour wash. |
112 | Wiringpointfortwowayslightwith1.5sq.mm.F.R. PVCinsulatedmultistrandsinglecorecopperconductor cableininsulatedmultistrandsinglecorecopper conductor cable in in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduitpartly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, GP Box and two number twonosmodulartypeswitch &ceilingrose/angle/ batten holder on 3 mm thick phanolic laminated backelite sheetetc.,complete inallrespect,asdirected,including matching colour wash. |
113 | Wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single corecopperconductorcablePVCconduitwith1.5sq. mm.FRLSHPVCinsulatedmultistrandcoppercableas earthwiredrawninsidetheconduit.,GPBox,modular type switch & ceiling rose on 3 mm. thick backelite etc., complete in all respect including matchingwash. |
114 | Wiring point for 5A plug with 1.5 sq. mm.FRLSH PVC insulatedmultistrandsingle core copper conductor cable inPVCconduitwith1.5mm.FRLSHPVCinsulated multistrand copper sq. cable as earthwire drawn inside the conduit concealed in wall and partly laid in slab alongwith the reinforcement before concreting,and modulartypeswitchandsocketetc.,completeinall respect including matching colour wash. |
115 | SupplyandfixingofdoorchimeonpolishedMDFEG /Teak ply board including making connections etc. complete in all respect. |
116 | Wiringpointforexhaustfanwith1.5sq.mm.FRLSH PVCinsulatedmultistrandsinglecorecopperconductor cableinPVCconduitwith1.5sq.mm.FRLSHPVC insulated multistrand copper conductor cable as earthwire drawninsidetheconduitpartlyconcealedinwalland partlylaidinslabalongwiththereinforcementbefore concreting,completewithGPBox,15Aswitchtype switch & ceiling rose on 3 mm thick phenolic laminated backelitesheetetc.,completeinallrespectincluding matching colour wash. |
117 | Supply and fixing hexagonal/Round G.P.fan box of approvedmakemadeupof1.0mmthickISIMarked G.P.sheet spot welded Four to Eight holes of 25.4 mm for pipeentryofthebox.Holesshouldbesemi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwedfittedwith300mmroundzinkcotedM.S Bar X 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work. |
118 | Wiring point for call bell with 1.5 sq. mm. FRLSH PVC insulated multistrand single core copper conductor cablen PVCconduitwith1.5sq.mm.FRLSHPVCinsulated multistrandcopperconductorcableasearthwiredrawn inside the conduit. partly concealed in wall and partly laid inslabalongwiththereinforcementbeforeconcreting completeGPBoxandmodulartypebellpushor2pin socket etc, |
119 | Supply and fixing of power plug with 15A/250 volt flush typeswitchand5pin15A/250Vflushtypeuniversal socket in suitable M.S. box of 175mm x 100mm x 50mm sizewithphenoliclaminatedbakelitesheetcover3mm thick fixed with brass machine screw and cup washer. |
120 | Supply and fixing of power plug with 20Amp./250 volt flush type modular switch and 5 pin 20 A/250 volt flush typeuniversalmodularsocketswitchonconcealedM.S boxincludingsupplyofallmaterial,labourT&Petc. required for proper completion of work. |
121 | S/f of Call Bell |
122 | S/o Invertor wiring Point for Light/Fan/Plug with 1.5mm Copper wire |
123 | S/f of Electronics Fan Regulator moduler type |
124 | Wiring point for fan /fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulatedmultistrandsingle core copperconductor cableinheavyguagerigidsteel conduitpipeonsurfacecompletewith14 SWG copper earth continuity wire, modular type switch & ceiling rose on 3 mm. thick phenolic laminated backelite sheet etc, complete in all respect. |
125 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
126 | 1 or 2 Module |
127 | 3 Module |
128 | 4 Module |
129 | 6 Module |
130 | 8 Module |
131 | Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. |
132 | 5/6 amps switch |
133 | 3 pin 5/6 amp socket outlet |
134 | Telephone socket outlet |
135 | TV antenna socket outlet |
136 | Supply andfixingandconcealingofPVC conduit pipe with ISI mark embossed and with PVCaccessoriesconfirming to IS No. 3419for drawing wires accessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin / adhesive to makethecompletepipingrigid,plasteringwithcement sandmortarfinishedtothelevelwithmatchingcolour washincludingcostofallmateriallabourandT&Petc required for proper completion of the work as per directions and to the satisfaction of Engineer in charge. |
137 | 20mmdia.2mm thick PVC conduit |
138 | 25 mm dia 2 mm thick PVC conduit. |
139 | 32 mm dia 2 mm thick PVC conduit. |
140 | 40 mm dia 2 mm thick PVC conduit. |
141 | Supply and fixing of 2/3/4 ways round PVC junction box confirming to ISS PVC conduit concealed in wall, keeping its level upto plaster duly provided with propersizecover,screwedasdirectedatsitebythe EngineerI/Cwithsupply ofallthematerial,labourand T&P required for proper completion of work. |
142 | 20mmdia.2mm thick PVC conduit |
143 | 25 mm dia 2 mm thick PVC conduit. |
144 | 32 mm dia 2 mm thick PVC conduit. |
145 | 40 mm dia 2 mm thick PVC conduit. |
146 | Supply and wiring of submains with 2 nos. 2.5 sq.mm @ with 1 no. earth wire of 1.5 sq.mm FRLSH PVC insulated 1100 V grade single core multisranded copper conductor cable in existing PVC conduit complete , including supply of all material , labour and T & P etc. required for proper completion of the work as directed by Engineer in charge. |
147 | Supply and wiring of submain with two number 4 sq.mm. FRLSHPVCinsulated1100Vgrademultistrandsingle core copper conductor cable in 20 mm dia heavy duty (2 mm thick) PVC conduit with one no. 2.5 sq. mm. FRLSH PVCinsulatedmultistrandcopperconductorcableas earth continuity wire drawn in conduit partly concealed in walland partlylaid in slab alongwith reinforcement beforeconcreting,including matchingcolourwashetc. complete in all respect. |
148 | Supplyandwiringofsubmainwithtwonumber6sq. mm.FRLSHPVCinsulated1100Vgrademultistrand singlecorecopperconductorcablein25mmdiaheavy duty (2mmthick)PVCconduitwithonenumber4sq. mm. FRLSH PVC insulated multistrand copper conductor cableasearthcontinuitywiredrawninconduitpartly concealed in wall and partly laid in slab alongwith reinforcementbefore concreting including matching colour wash etc. complete in all respect. |
149 | Supply and wiring of 4 number 16 sq. mm. PVC insulated 1100Vgradesinglecore Copperconductorcablein40 mm dia PVC conduit partly concealed in wall and partly laidinslabalongwithreinforcementbeforeconcreting, with two number 10 sq mm single core Copper conductor cableasearthcontinuitywiredrawnincouditincluding matching colour wash etc, complete in all respect. |
150 | S/w of Submain FRLSH Insulated multistand copper cond cable in HG PVC Conduit pipe concealed in wall as follws 4 sqmm 4 wire |
151 | Supplyandwiringof4number6sq.mm.FRLSHPVC insulated1100Vgrademultistrandsinglecorecopper conductorcable in32mm diaheavy duty (2mm thick) PVC conduit with 2 nos 4 sq.mm.FRLSH PVC insulated multistrandcopperconductorcableasearthcontinuity wire drawn in conduit.partly concealed in wall and partly laidinslabalongwithreinforcementbeforeconcreting including matching colour wash etc, completeinall respect. |
152 | Supply and wiring of 4 number 10 sq. mm. FRLSHPVC insulated1100Vgrademultistrandsinglecorecopper conductor cable in heavy duty (2 mm thick) PVC conduit with2 nos6sq.mm.FRLSHPVCinsulatedcopper conductor cable as earth continuity wire drawn in conduit.partlyconcealedinwallandpartly laidinslab alongwith reinforcement before concreting including matching colour wash etc, complete in all respect. |
153 | S&F surface/flush mounting 8ways SPN distribution boardwith additional metal doorwithoutMCB complete in all respect, as directedbyEngineer in charge. |
154 | S & F surface/Flush mounting 12 ways SPN distribution board withadditionalmetaldoor withoutMCB completeinall respect, asDirect by Engineer in Charge. |
155 | S&Fsurface/Flushmounting6waysTPNdistributionboard without additional board without MCB complete in all respect, as directed at site byEngineer in charge. |
156 | S&Fsurface/Flushmounting8waysTPNdistributionboard without additional door without MCB complete in all respect,as directed at site byEngineer in charge. |
157 | S & Fsurface/Flush mounting 12ways TPNdistribution board with additional metal door without MCB complete in all respect,as directed at site byEngineer in charge. |
158 | S & F surface/Flush mounting 4ways V TPN distribution board withadditionalmetaldoor withoutMCB completeinall respect,as directed at site byEngineer in charge. |
159 | S & F surface/Flush mounting 6ways VTPN distribution board withadditionalmetaldoor withoutMCB completeinall respect,as directed at site byEngineer in charge. |
160 | S & F surface/Flush mounting 8waysV TPN distribution board with additional metal board without MCB complete in all respect. |
161 | S&F of 6 Amp. to 32Amp. 4 pole MCB (10 KA) C Curve CAT-A |
162 | S&F of 40 Amp. 4 pole MCB (10 KA) CAT-A |
163 | S/f of 63A/4 Pole MCB CAT-A |
164 | S&F of6 Amp. to 32Amp. DP MCB (10 KA) C Curve CAT-A |
165 | S&F of 40Amp. DP MCB (10 KA) C Curve CAT-A |
166 | S&F of 63Amp. DP MCB (10 KA) CAT-A |
167 | S/f of 6 to 32 A MCB C-Type |
168 | S&Fandmakingconnectionof25A2pole30mAELCB/ RCCBofDinRailMountingcompleteinallrespectasper direction and satisfaction to the Engineer in charge. |
169 | S&Fandmakingconnectionof40A2pole30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge. |
170 | S&Fandmakingconnectionof63A2pole30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge. |
171 | S & F sheet steel enclosure for S.P/ D.P. MCB with neutral link and earth terminal. |
172 | S & F sheet steel enclosure for T.P./Four PoleMCB. |
173 | S&F single pole MCB blanking plate |
174 | SupplyandlayingofaluminiumconductorPVC insulatedarmouredservedsheathedcables1100Volts gradeatadepthof750mmbelowgroundlevelovera cushionof75mm.thicksandallaroundandprotected with burnt bricks on sides and on top. On surface the cable run shall be fixedon M.S. clamps etc. of suitable size or asdirectedbytheEngineer-Incharge, completeinall respect.Thearmouringofthecableshallbeproperly connected with the earth conductor by clamps etc. |
175 | 35 sq. mm 3-1/2 core |
176 | 50 sq. mm 3-1/2 core |
177 | 70 sq. mm 3-1/2 core |
178 | 95 sq. mm 3-1/2 core |
179 | 120 sq. mm 3-1/2 core |
180 | 150 sq. mm 3-1/2 core |
181 | 185 sq. mm 3-1/2 core |
182 | 240 sq. mm 3-1/2 core |
183 | 300 sq. mm 3-1/2 core |
184 | Supplyandfixingofbrassnickleplatedcompression glandforPVCinsulated&armouredservedsheathed, undergroundcable including rubber ring etc.complete in all respect. The armouring of the cable shall be properly connectedwiththeearthasperdirectionofEngineer- Incharge. |
185 | 16 sq. mm 2 core |
186 | 4 sq. mm 3 core |
187 | 6 sq. mm 3 core |
188 | 4 sq. mm 4 core |
189 | 6 sq. mm 4 core |
190 | 10 sq. mm 4 core |
191 | 16 sq. mm 4 core |
192 | 25 sq. mm 3-1/2 core |
193 | 35 sq. mm 3-1/2 core |
194 | 50 sq. mm 3-1/2 core |
195 | 70 sq. mm 3-1/2 core |
196 | 95 sq. mm 3-1/2 core |
197 | 120 sq. mm 3-1/2 core |
198 | 150 sq. mm 3-1/2 core |
199 | 185 sq. mm 3-1/2 core |
200 | 240 sq. mm 3-1/2 core |
201 | 300 sq. mm 3-1/2 core |
202 | Supplying following 1.1kV grade, heavy duty XLPE insulated, FRLS type armoured /Unarmured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete as required. |
203 | 3.5C x 185 sqmm aluminium conductor, A2XWY. |
204 | 3.5C x 120 sqmm aluminium conductor, A2XWY. |
205 | 3.5C x 95 sqmm aluminium conductor, A2XWY. |
206 | 3.5C x 70 sqmm aluminium conductor, A2XWY. |
207 | 3.5C x 50 sqmm aluminium conductor, A2XWY. |
208 | 3.5C x 35 sqmm aluminium conductor, A2XWY. |
209 | 4C X 25 sqmm copper conductor, 2XWY |
210 | 4C X 16 sqmm copper conductor, 2XWY |
211 | 4C X 16 sqmm copper conductor, 2XY |
212 | 4C X 10 sqmm copper conductor, 2XWY |
213 | 4C X 6 sqmm copper conductor, 2XY |
214 | 4C X 4 sqmm copper conductor, 2XY |
215 | 3C X 10 sqmm copper conductor, 2XWY |
216 | 3C X 6 sqmm copper conductor, 2XWY |
217 | 3C X 4 sqmm copper conductor, 2XY |
218 | 1C X 16 sqmm copper conductor, 2XY |
219 | 1C X 10 sqmm copper conductor, 2XY |
220 | 2C X 6 sqmm copper conductor, 2XY |
221 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. |
222 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
223 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
224 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
225 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
226 | Supply, installation, testing and commissioning of indoor floor mounted/ wall mounted, IP42, factory built, modular, sectionalised, compartmentalized, extendable type LT cubicle panel of suitable size suitable for operation on 433/415 volts, 50 Hz AC 3 phase 4 wire supply system fabricated from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates with stiffeners wherever required, having vibration free structure chemically treated with seven tank process or better before painting for surface treatment and powder coated in approved shade, with suitable electrolytic grade high conductivity bus bars extensible, DMC/ SMC (whichever is superior) bus bar supports, with short circuit withstand capacity as mentioned ,bottom base channel of section not less than 100mmX 50mmX 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm. PVC insulated FRLS copper conductor S/C cable for voltage & current respectively, including providing and fixing following switch gears and as per schedules ,technical specifications etc.complete as required. |
227 | Main Panel |
228 | Incomer : |
229 | MCCB 415V, 50Hz, 100A, 4P, 25kA for 1 sec rated microprocessor based MCCB with inbuilt LSIG protection- 1 Nos. |
230 | Metering (1 No.) Multifunction meter with inbuilt selector switch for measurement of current, voltage, power factor, KVA, kVAh, KVArh, KVAR, frequency, ,KWHr (both line and phase) complete as per specifications |
231 | Indication lamps LED type phase indication lamps suitable for 230V,50Hz AC (red, yellow, blue) - 1 Set. LED type Indication lamps for breaker, suitable for 230V,50Hz AC supply (on, off, trip) - 1 set |
232 | CTs: 415V ,100/5A, 15VA, CL-1 current transformer for metering |
233 | Busbar : |
234 | Busbar (1 Set - 4P + E) Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 200 A, 25 kA for 1 sec of required length and cross sectional area. |
235 | Outgoing : |
236 | Supply and burying of 600mm x 600mm x 3mm copper plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and two earthing lead of two no. 8 SWG copper wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and copper wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. complete in all respect. |
237 | Supplyand fixingofhorizontalair termination(roof conductor)of25mmx3mmG.I.strip,G.I.clampson surface complete in all respects as approved by Engineer- in-charge. |
238 | Supplyandfixingofverticalairterminationfinalrod comprising of 300mm long x 25mm dia. Copper rod with onepointedprongand100mmdiax3mmthickbase plate etc. complete in all respect. |
239 | Supply and fixing of vertical down conductor of 32mm x 6mmG.I.stripetc.onapprovedclampsonsurfacefor lightningconductorcompleteinallrespects(fortwo storeyed Buildings). |
240 | Supply and laying of 32 mm x 6 mm G.I. strip from earth electrodedirectlyinthegroundasrequiredcompletein all respect. |
241 | Supply and laying of 32mm x 6mm copper strip from earth electrode directly in the ground as required complete in all respect. |
242 | Supplyandfixingoftwonumber8SWGG.I.wirein 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. |
243 | Supplyandfixingoftwonumber8SWG copperwirein 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. |
244 | Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
245 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
246 | 200 mm dia (OD-200 mm & ID-175 mm nominal) |
247 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. |
248 | 100 mm dia |
249 | 300 mm dia |
250 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
251 | Providing & making of inspection man hole chambers offollowing size as detailed below with 230 mm thick brick work plaster inside and outside both, PCC flooring including excavation, providing and fixing of heavy duty ISI mark SFRC cover with frame complete with RCC slab and complete as required per specifications or upto the satisfaction of engineer-in-charge. |
252 | 1000mm X 1000 mm(depth 1.200 mtr) - 230mm Thick |
253 | 800mm X 800 mm (depth 0.800 mtr) - 230mm Thick |
254 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
255 | Providing & fixing in position 1000 mm wide, Electrical Insulating Mats, 2mm thick, suitable upto 1.1 KV grade including cutting to required length complete as required per specifications or upto the satisfaction of engineer-in-charge. |
256 | Supply & fixing in position approved shock treatment chart written in English Hindi and Local language.These charts shall be framed in wooden frame & covered with clear glass. |
257 | Supply of Tool & First Aid Box with all necessary tools for maintenance of electrical installation & First aid. |
258 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
259 | 100 mm width x 50 mm depth x 1.6 mm thickness |
260 | 150 mm width x 50 mm depth x 1.6 mm thickness |
261 | 300 mm width x 50 mm depth x 1.6 mm thickness |
262 | 450 mm width x 50 mm depth x 2 mm thickness |
263 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
264 | 100 mm width X 50 mm depth X 1.6 mm thickness |
265 | 150 mm width X 50 mm depth X 1.6 mm thickness |
266 | 300 mm width X 50 mm depth X 1.6 mm thickness |
267 | 450 mm width x 50 mm depth x 2 mm thickness |
268 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
269 | 100 mm width X 50 mm depth X 1.6 mm thickness |
270 | 150 mm width X 50 mm depth X 1.6 mm thickness |
271 | 300 mm width X 50 mm depth X 1.6 mm thickness |
272 | 450 mm width x 50 mm depth x 2 mm thickness |
273 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Cross member” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
274 | 100 mm width X 50 mm depth X 1.6 mm thickness |
275 | 150 mm width X 50 mm depth X 1.6 mm thickness |
276 | 300 mm width X 50 mm depth X 1.6 mm thickness |
277 | 450 mm width x 50 mm depth x 2 mm thickness |
278 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
279 | 100 mm width X 50 mm depth X 1.6 mm thickness |
280 | 150 mm width X 50 mm depth X 1.6 mm thickness |
281 | 300 mm width X 50 mm depth X 1.6 mm thickness |
282 | 450 mm width x 50 mm depth x 2 mm thickness |
283 | Supply andfixing of recess/Surface/Pendent mountinground6Watt8WattLEDDownLighter havingPowdercoateddiecastaluminiumhousing withheatsink,diffuser/Reflectoranddriverset complete in all respect. CAT-AAA |
284 | Supply and fixing ofrecess/ Surface/ Pendent mountinground 10to15WattLEDDownLighter havingPowdercoateddiecastaluminiumhousing with heatsink,diffuser/Reflectoranddriverset complete in all respect. CAT- AAA |
285 | Supply and fixing ofrecessmounting round 15 to 18 WattLED DownLighterhavingPowdercoated die castaluminiumhousingwith heatsink,diffuser/ Reflector and driver set complete in all respect. CAT- AAA |
286 | Supplyandfixingof36Wattto46Wattindoor Recess mounting LED Square Fitting for Armstrong CeilinghavingPowdercoateddiecastaluminium housing body withextended heat sink and diffuser of SpecialPolycarbonatemeterialanddriverset complete in all respect. CAT-AAA |
287 | SupplyandfixingofLEDTubeLightwithbatten suitable forupto1X 22watt LED tube lightfitting includingtubeonSurfacecompleteinallrespect. CAT-AAA |
288 | Supply and fixing ofwater tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection . complete in allrespect. CAT-AAA |
289 | Supply & Fixing of40WattLED Surface Mounting weatherproof Luminaire with PCHousing andopal finishcoverconfirmingtoIP65Completeinall respect. CAT-AAA |
290 | Erection andtestingofexhaustfanontheexistinghole withsuitablesizeofragbolts,nutsandwashersetc., complete in all respect. |
291 | Erectionandtestingofceilingfanandregulatoretc. excluding supply of down rod, complete in all respect. |
292 | Cost of 1200mm Ceilling Fan sweep |
293 | Cost of 300mm Ex-Fan Fan |
294 | Supply and fixing of batten / angleholder complete in all respect. |
295 | Supply, installation, connections,testing & commissioning of 2 KVA inverter with minimum 90 minutes battery backup complete with suitable arrangement for placeing maintenance free batteries and inverter with connecting power input and inverter to batteries complete as per site requirement and full satisfaction of engineer incharge. |
296 | Supply, installation, connections,testing & commissioning of 3 KVA inverter with minimum 90 minutes battery backup complete with suitable arrangement for placeing maintenance free batteries and inverter with connecting power input and inverter to batteries complete as per site requirement and full satisfaction of engineer incharge. |
297 | Supply , Installtion , Testing and comissioningof armoured 6 coreMultimode OFC cable for interfloor switch connectivity |
298 | Supply , Installtion , Testing and comissioningof 6 port loaded LIU with adaptor plates , pigtel cables for connections |
299 | Supply , Installtion , Testing and comissioningof SC-LC singlemodefiber patch cord. |
300 | Supply , Installtion , Testing and comissioning of CAT6 information outlet (I/O) for Data, Voice & Wi-Firack |
301 | Supply , Installtion , Testing and comissioning of loaded 24 port CAT6jack panel for CAT6 cable termination. |
302 | Supply , Installtion , Testing and comissioning of CAT6 patch cord 3 feet for rack side switch termination for user End. |
303 | Supply , Installtion , Testing and comissioningof CAT6 patch cord 7 feet for user termination to information outlet Rack End. |
304 | Supply , Installtion , Testing and comissioningof 1, 2 and 4 port face plate white for I/O fixing at user side. |
305 | Supply , Installtion , Testing and comissioningof 6Uwall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos of hardware pkts. |
306 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
307 | 2 Pair |
308 | 4 Pair |
309 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
310 | Supply & installation of IP Indoor Dome style1/1.8 "" 5 MPCMOS Sensor Progessive with effective 2592 (H) x 1944(V)pixels ,Video Compresion H.265/M-JPEG, (Color)/F1.2, 0 Lux (IR On), Fixed lense 3.6mm, Smart IR Distance upto 30 mtr, WDR ,Auto Iris ,Dual Streaming ,Fram rate 25 FPS on 1080 MP resolution , Electronic Shutter Speed Auto/Manual, 1/3(4)~1/100000s, 3D DNR , Motion detection , Ethernet port 10/100 Mbps, ,ONVIFsupport,Power input 12 V DC and Power over Ethernet ( No need of additional power cable ) & 3D adjustment ,Wall mount . Heavy duty metal body, IP65 & IK 10 with dust proff cable connectors cap. |
311 | Supply, installation, testing and commissioning of 24channel NVR with 6 sata connectvity ,support video compression H.264,H.265 & H.265+ ,Support up to 5 MP cameras ,Support Recording resolution 5 MP/4 MP/3MP/1080p/UXGA/720p/VGA/4CIF/DCIF, 16 Ch. live output , Support Audio input , Support upto 25 FPS @ 2 MP & all other resultion also, HDD Support 6 TB each port ,both MPEG 4 and H.264/H.265 recording formats. PTZ support,Tour support ,manual/motion smart recording options, Buzzer ,alaram input/output, Auto maintanace features ,2 Usb 2.0 ports, Remote monitoring software ,Motion detection , power consumoption less than 30 w on full load ,Support all ONVIF cameras . HDMI,VGA Output The NVR with IP connectivity, CMS/WebSoftware with all necessary software |
312 | Supply & installation4 TB Survillance Hard disk Drive |
313 | Supply & installation of 32" inch LED colour Full HD TV monitor for Live View and Replay of Recorded View. |
314 | Supply & installationof 6 port 10/100/100mbps POE switch. |
315 | Supply Installation Testing & Commissioning ofCAT6A Cable in existing PVC Conduit. |
316 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. |
317 | 2 Loop Panel |
318 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. |
319 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. |
320 | Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. |
321 | Supplying, installation, testing & commissioning of addressable beam detector with short circuit isolator (inbuilt or seperate) complete with emitter and receiver including connections with remote test features etc complete as required. |
322 | Supplying, installation, testing & commissioning of digital audio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required. |
323 | Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. |
324 | Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. |
325 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. |
326 | Speaker cable Single pair, 2-core, 1.5 sqmm |
327 | Supplying, installation, testing and commissioningof 50 kVA silent type DG set ( with acoustic canopy) complete with following accessories |
328 | Engine: Supplying, installation, testing and commissioningof 4 stroke Diesel engine of suitable BHP at 1500 rpm suitable for 50 KVA output of the alternator at site condition, capable of taking 10% overloading for one hour in any 12 hrs of runningwithout loosing its rpm complete with Dynamically balanced flywheel,Flexible coupling,Exhaust gas turbo charged with Cooling System , Automatic safety control in case of low lubrication oil pressure, Automatic safety control in case of high water temperature. Automatic overspeed trip protection. The engine shall have Lubrication oil pump.Lubrication oil filter.Lubrication oil cooler.Bye-pass filter,Fuel pump,Fuel Filter,Hoses for fuel tank.Air intake manifold.Air cleaner dry type. Governor EFC type.Selfstarter.Alternator for battery charging.Residential silencer. Flexible pipe for silencer. Batteries for excitation with Battery charger.Techometer with hour meter,Auto mains failure controller, Engine control panel as applicable & as per manufacturers standard . |
329 | Alternator: Supplying, installation, testing and commissioningof synchronous alternator rated 50 kVA at 1500 rpm, 3 phase ,50Hz AC supply with 0.8 pf (lagging) at site condition.The alternator shall have SPDP enclosure (IP-23), brushless contineous duty, self excited and self regulated suitable for the environmental conditions and with H class of insulation.The alternator shall be fitted with thermistors (controlled by AMC controller) for winding and bearing temperature and space heaters, AVR , battery charger for self excitation etc. complete in all respects.The alternator shall be fitted with suitable arrangement to bring out bus duct of required sizes as mentioned in the SLD, along with CT for restricted earth fault protection and droop compensation .The rate shall include complete supplying, installation, testing and commissioningrates including cost of all tools and accessories (as mentioned below and any other required) required to Complete the job in full respect. |
330 | Exhaust: Design, manufacture, supply, erection, testing & commissioning of exhaust pipingincluding suitable flexible bellows, bends, load support, MS cladding truss structure/support, thermal insulated mineral wool, making ofMS"Y" Piece - Before Silencer & After Silencer (as per manufacturers standrd design & site requirement), minimum 75 mm thick up to silencer (density 48Kg/cu metre). Wire chicken mesh over insulation and 24 gauge aluminium sheet wrapping over the exhaust pipes upto silencer and from silencer to direct exhaust to atmosphere including all supports, steel brackets etc. as required including Supply & Fixing of miscellaneous structural support for horizontal/ vertical exhaust & raw water/fuel piping including fabrication, hardwares and painting complete as required or upto the satisfaction of engineer-in-charge. All MS supports shall be to have two coats of red oxide primer and two or more coats of synthetic enamel paint complete as required per specifications or upto the satisfaction of engineer-in-charge. |
331 | Plumbing Work |
332 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required. |
333 | W.C. pan with ISI marked white solid plastic seat and lid. |
334 | Providing and fixing Health faucet with 1 metre long Flexible Tube andCP wall hook with PVC & SS Screwswherever required complete as directed by the Engineer-in-charge |
335 | Providing and Fixing White vitreous china Under counter wash basin with C.I. brackets painted white, 15 mm CP Brasspillar cock, 32mm dia. C.P. waste, C.P chain and rubber plug, C.P. connecting pipe to wall and C.P wall flange and rubber adapter for waste connection complete includingcutting and making goodthe wallswherever required etc. complete in all respect as per direction of Engineering-in-charge. |
336 | Providing and fixing white vitreous china infrared medium range manual urinal of approx. size 378 x 310 x 610 mm, havingwater inlet from back side, including fixing to wall with suitablebrackets all as per manufacturers specification and direction ofEngineer-in-charge. |
337 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. |
338 | Granite Stone of approved shade |
339 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
340 | Kitchen sink with drain board 510x1040 mm bowl depth 250 mm |
341 | Providing and Fixing 15 mm nominal bore CP Brass long body bib cock of approved quality conforming to IS Standards etc. complete in all respect as per direction of Engineering-in-charge.(In the bathroom for bathing purposes). |
342 | Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112 mm distance from wall of standard shape withbracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. ) |
343 | Providing and fixing CP Brass Bottle Trap of approved quality & make etc. complete in all respect as per direction of Engineering-in-charge. |
344 | 32 mm dia |
345 | Providing and fixing C.P. brass angle valveof approved quality conforming to IS:8931 etc. complete in all respect as per direction of Engineering-in-charge. 15mm nominal bore |
346 | Providing and FixingC.P. Brass Toilet paper holder,including cuttingand making good the walls wherever required etc. complete in all respect as per direction of Engineering-in-charge. |
347 | Supply, installation , testing &commissioning of 15mm CP brass single lever concealed bath and shower wall mixerwith divertor withshower head, spout, OH shower with adjustable type armwith wall flange with slip fit connection & hand shower with flexible pipe with bracket complete as required by the engineer in charge. |
348 | Providing and fixing soil, waste and vent pipes : |
349 | 100 mm dia |
350 | Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 |
351 | Providing and Fixing M.S. Holder bat clamp (factory manufactured) of approved design to sand cast iron / cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5 mm flat of specified shape, projecting 75 mm outside the wall surface and fixed on wall with 4 Nos, 6 mm diameter expansion hold fasteners including drilling necessary holes in brick wall /CC/RCC surface and the cost of bolts etc. . The pipes shall be fixed to the already fixed brackets with the help of 30 mmx1.60 mm galvanized M.S. flats of specified shape and total length 420 mm and shall be fixed with M.S. nuts, bolts and washers of size 25x6 mm, one bolt on each side of the pipe. |
352 | Total bracket length 580 mm of approved shape and design, (for single 100 mm dia pipe) |
353 | Total bracket length 810 mm of approved shape and design, (for single 100 mm dia pipe) |
354 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. |
355 | 100 mm dia |
356 | Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
357 | Providing and fixing plain bend of required degree. |
358 | 100 mm dia |
359 | Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 |
360 | Providing and fixing single equal plain junction of required degree : |
361 | 100x100x100 mm |
362 | Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
363 | Providing and fixing double equal plain junction of required degree. |
364 | 100x100x100x100 mm |
365 | Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 |
366 | Providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : |
367 | 100 mm |
368 | Sand cast iron S&S as per IS - 3989 |
369 | Providing and Fixing 100 mm dia Terminal guard for Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
370 | 100 mm |
371 | Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
372 | Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe |
373 | 100 mm dia |
374 | SS 304 grade coupling with EPDM rubber gasket |
375 | Providing and fixing M.S. stays and clamps for sand cast iron hubless pipes of diameter: |
376 | 100mm |
377 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : |
378 | 100 mm inlet and 100 mm outlet |
379 | Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
380 | Providing and FixingG.I. Reducing elbow (Floor drain) of 100 x 50 mm in cement concrete 1:2:4 at all levels for floor drains (excluding cost of grating) for connection to floor traps in sunken portions, complete as perdrawings and as per approval of the engineer-in-charge. |
381 | Providing and fixing on wall face unplasticised Rigid uPVC rain water pipes including couplerconforming to I.S:4985of 6 Kg/cm2 |
382 | 160 MM Diameter |
383 | Providing and Fixing to the inlet mouth of rain water pipe SS 304 grating of following diameter complete in all respects as per direction of the engineer-in-charge |
384 | a) For 160 mm dia |
385 | Providing and FixingG.I. "C" class pipe complete with G.I. Fittings and clamps, including cutting and making good the walls etc.(Internal work) |
386 | a)32 mm dia |
387 | b)40 mm dia |
388 | c)50 mm dia |
389 | Painting of G.I. Pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. |
390 | a)32 mm dia |
391 | b)40 mm dia |
392 | c)50 mm dia |
393 | Providing and fixing G.I. Inlet fittings with maximum 3 inlets 32,40 & 50 mm size fabricated from 100 mm dia G.I. pipes and welded G.I. sockets, fixed to C.I. Trap with joints and set in cement concrete(1:2:4)complete as directed by Engineer-in-charge. |
394 | Providing and Fixing SS 304 Grating with frame and SS Screws casted heavy 125 mm diacomplete as directed by Engineer-in-charge. |
395 | Providingand fixing castbrasscleanoutplug/ floor cleanout with suitableinsert keysfor opening,malethreaded joint withG.I. socketcaulked to spun soil pipe including cost of joint etc.completeas directed by Engineer-in-charge. |
396 | 100 mm dia |
397 | Making core cutting holes for C.I. Pipe of 100 mm dia. etc. in R.C.C. floors and roofs for passing C.I. pipe etc. and repairing the hole after insertion of C.I. pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
398 | Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer-in-charge. |
399 | WATER SUPPLY(INTERNAL AND EXTERNAL) |
400 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - exposed on wall |
401 | 15mm nominal bore |
402 | 20 mm nominal bore |
403 | 25 mm nominal bore |
404 | 32mm nominal bore |
405 | 40 mm nominal bore |
406 | 50 mm nominal bore |
407 | 65 mm normal bore |
408 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. CONCEALED WORK, including cutting chases and making good the wall etc. |
409 | 15 mm nominal outer dia pipes |
410 | 20 mm nominal outer dia pipes |
411 | 25 mm nominal outer dia pipes |
412 | 32 mm nominal outer dia pipes |
413 | 40 mm nominal outer dia pipes |
414 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External works |
415 | 25 mm nominal bore |
416 | 32 mm nominal bore |
417 | 40 mm nominal bore |
418 | 50 mm nominal bore |
419 | 65mm nominal bore |
420 | 80mm nominal bore |
421 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : |
422 | 20 mm dia |
423 | 25 mm dia |
424 | 32 mm dia |
425 | 40 mm dia |
426 | 50 mm dia |
427 | 65 mm dia |
428 | 80 mm dia |
429 | Providing and filling sand of grading zone v or coarser grade all-round the G.I. Pipe in external work |
430 | 25 mm dia pipe |
431 | 32 mm dia pipe |
432 | 40 mm dia pipe |
433 | 50 mm dia pipe |
434 | 65 mm dia pipe |
435 | 80 mm dia pipe |
436 | Providing and fixing forged brass lever operated ball valve of full flow with forged brass ball (Machined to mirror smooth finsh with hard chrome plated) and spindle with setting and gland of superior quality having minimum working pressure of 16 kg/cm2 etc. complete in all respect. |
437 | 20 mm dia |
438 | 25 mm dia |
439 | 32 mm dia |
440 | 40 mm dia |
441 | 50 mm dia |
442 | Providing and fixing C.I butterfly valve, wafer end type class PN 1.6 as per I.S:13095 or BS:5155, including necessary nuts, bolts, gaskets etc., complete (flanges to be paid separately) |
443 | 65 mm dia |
444 | 80 mm dia |
445 | Supply, installation , testing & commissioning ofinsect vermin -proof coupling to vent pipes of underground tank/overhead tank with threaded or flanged joints, including M.S. flanges, nuts, bolts, 3mm thick rubber insertions complete. |
446 | 80mm nominal bore |
447 | Constructing masonrychamber 30x30x50 cm with FPS bricks, inside withbrick work in cement mortar1:4(1 cement: 4 Coarse sand) for stop cock, with C.I. surfacebox 100x100x75 mm(inside) with hinged cover fixed in cement concrete slab1:2:4 mix (1 cement: 2coarse sand:4gradedstone aggregate 20 mm nominal size) necessary excavationfoundation concrete 1:5:10 mix (1 cement : 5 fine sand and10graded stone aggregate 40 mm nominal size)and insideplastering withcementmortar1:3(1 cement: 3coarsesand) 12mm thickfinishedwitha floatingcoatofneatcement complete as per standard design. With common burnt clay FPS (non modular) bricks of class designation 7.5 |
448 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. |
449 | Providing and placing three tanks on mumty on polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
450 | Construction of rain water harvesting pit (3 m dia and of total minimum effective water volume of 21 m3 - 3 m water depth per structure including all earth work in excavation, back filling with available excavated earth, with disilting and oil trap, necessary compaction and shifting of surplus earth outside by mechanical means as directed by the Project Incharge, including drilling with RC/DC/Calyx rig having 400/450mm dia bore size in all kind of strata except hard rock,PCC 1:5:10 , 200mm thick foundation concrete, brick work in cement mortar 1:4 (1 cement : 4 coarse sand)/RCC as per structural design to be approved...contd... |
451 | .....contd....PVC coated safety steel foot rest of 12mm dia MS bars grouted rigidly in cement concrete 1:2:4 @300mm c/c, 200mm thick RCC tank cover slab in cement concrete M20 i/c providing and placing necessary steel raft, bars and to keep the provision of removable slab of approx. 1 m x 1m size, filling 300mm, 300mm & 300mm thick of 40-65mm nominal size graded stone aggregate, small stone and sand layer respectively, 100mm dia CI vent pipe, ...contd... |
452 | ..contd... 250mm dia uPVC slotted pipes 6Kg./sq cm working pressure, filling around theslotted pipes andpacking 3mm to 6mm sized graded and screened rounded pea gravel duly washed fabricating and placing grating at the mouth of pipes, placing 2 nos. 560mm dia SFRC manhole cover with frame etc. i/e all necessary materials and equipments required for all relevant operations as shown in the drawing. The depth of drilling and slotted pipes shall be approximately to terminate above the underground aquifer. Volume specified is "effective" water storage volume as per detailed sketch. |
453 | ConstructingDisiltling chamber/Oil Trap of brick work with bricks of class 75 with cement mortar 1:5 (1 cement:5 fine sand) plastering internal face with cement mortar 1:3 (1 cement: 3 fine sand and rough plaster on outerfacewith a floating coat of neat cement. R.C.C top slab with medium duty CI manhole cover and frame of 600 mm dia. The weight of cover to be not less than 58 kg & frame not be less than 58 kg as per standard design. Including excavation, dewatering, refilling, watering, ramming and removing the surplusexcavated material complete as required.(Allsizes are clear internal sizes). Depth shall be as per actual site condition and invert level. |
454 | belowin 300 mm thick layer at the bottom of Filter chamber, below effective depth. All three layers shall be separated by G.I Wire Mesh screen of appropriate size. |
455 | Size 1500 x 1000 x 1000 mm water depth (Total Depth shall be as per invert level of site) |
456 | Supply, Installation, Testing & Commisioning of reverse osmosos cum chiller unit with 40 lit. storage capacity, including 2no. Tapscfor outlet. |
457 | Tourist InformationCenter |
458 | Excavation in foundation in Ordinary soil (loamclay or sand) including lift upto 1.5m. And lead up to 30m. And including filling, watering and ramming of excavated earth into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the E.I.C. up to a distance of 30m. from the foundation trenches including all T&P phowarah and basket etc. complete. |
459 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
460 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8kM from the site of work and including watering dressing etc. Rate to include cost of all materila, labour and T&P etc. required for proper completion of the work. |
461 | Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge. |
462 | Providing & injecting chemical emulsion for Preconstructional anti-termite treatment and creating a chemical barrier under & around the column pits, wall trenches, basement excavation top surface of plinth filling junction of walls & floors,along the external perimeter ofbuilding expansion joints surrounding of pipes & coduits etc. complete plinth area of the building at ground floor only shall be measured as per I.S.6313 (part II 1981) Aldrine emlsifiable concentrate or any other approved material such as Chloropyriphos or Heptrachier or Chlordance will beused. Therateof application ofchemicalemulsionshallbeasfollows: (I) Treatment for masonary & foundation 5litres/ sqm.(II) Back fill in immediate contact with foundation 7.5 litres / sqm(III) Treatment of top surface of plinth filling 5 litres/sqm . (IV) Treatment of junction of wall and floor 7.5litres/sqm.(V) Treatment of soil along external perimeterof building 7.50 litres/sqm.(VI) Treatment of soilunder Apron along external perimeter 5litres/sqm |
463 | Cement concrete with 4 cm guage approvedstone ballast, approved coarse sand and cement in the proportion of 4:2:1 including supply of materials, labour and T&P etc. required for proper completion of the work. |
464 | Same as item 279 above but 2cm guage stone grit. |
465 | Cement concrete with 4cm. Guage approved stone ballast, approved coarse sand and cement in the proportion of 8:4:1 including supply of all materials, labour and T&P etc. required for proper completion for the work. |
466 | Damp Proof Coarse |
467 | 20mm (3/4") thick Damp proof course with cement and approved coarse sand 1:2 with and including water proofing material as ordered by the E.I.C. in the proportion as specified by the manufacturers, including supply of all materials, labour, T&P etc. required for proper completion for the work and including proper curing and shuttering as necessary. |
468 | As in item 360 above but 2.5cm (1") thick damp proof course of cement concrete consisting of 1:1.5:3 on part cement 1.5 parts approved coarse sand and 3 parts approved 13mm graded stone grit and including water proofing materials as ordered by the E.I.C. in the proportion as specified by the manufacturers, including supply of all materials, labour, T&P etc. required for proper completion for the work and including proper curing and shuttering as necessary. |
469 | Same as item no. 361 but 4cm thick |
470 | painting on DPC with two coats of air blown bitumen 85/50 or 85/25 @ 1.7kg/sqm. Approx. including cost of fuel if any. |
471 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stoneaggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed andonsolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
472 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : |
473 | Foundations, footings, bases of columns, etc. for mass concrete |
474 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
475 | Suspended floors, roofs, landings, balconies and access platform |
476 | Shelves (Cast in situ) |
477 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
478 | Columns, Pillars, Piers, Abutments, Posts and Struts |
479 | Stairs, (excluding landings) except spiral-staircases with water proof ply 12mm thick |
480 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick |
481 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) |
482 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. |
483 | (Note :- Cement content considered in this item is @ 330 kg/ cum.Excess/less cement used as per design mix is payable/recoverable separately). |
484 | All works upto plinth level |
485 | All works above plinth level upto floor V level |
486 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete for proper completion of the work and including supply of steel its wastage.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
487 | M-15 Sub Class (A) Brick work in 1:6 cement and sand of 1.25 fineness modulus mortar in foundation and plinth including supply of all materials, labour, T&P etc. required for proper completion of work. |
488 | As in item 302 to 307 above but in superstructure including necessary cutting and moulding of bricks and also including honey comb brick work, thickness of walls more than one brick and for extra labour to above items. |
489 | As in item no. 309 above but for one brick wall add for extra labour. |
490 | As in item no. 309 above but walls of half brick wall add for extra labour. |
491 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
492 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
493 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood |
494 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
495 | Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge |
496 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
497 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
498 | Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). |
499 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.0 mm thick |
500 | Providing and fixing 6mm thick toughened glass complete in all respects as per direction of the Engineer-in-charge. |
501 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately). |
502 | Roller Blinds:-Providing and fixing Roller Blinds as per the approved sample comprising of screen Fabric comprising of 25% polyester, 75% PVC with openness factor of 5%.Fabric weight 410-465 G weight per sqm, Thickness 0.67 mm. Healthy/safety standard - Oekotex Standard 100.Yarn count 18-19/cm, having fire resistance standard – NFPA 701 Method 1:2004 GB 50222-1995 (B1).The tear resistance should be complying to ISO4674 & breaking resistance – warp: > 1850 N/5cm, Weft: > 1400 N/5cm haing tear resistance of warp: > 135N and Weft: > 105N. Color fastness to Light 6-7/8(ISO 105 B02:1994).The Roller blind system consists of 38mm OD extruded out of Aluminium alloy 6063 T6 with silver anodized to provide an everlasting finish and luster, the rotary unit shall be 36mm in OD incorporating a clutch mechanism composed of low – flexing braided polyester cord with nylon core, Control Ball chain shall be composed of braided nylon cord (2mm dia) with high engineering grade plastic beads of 4.5mm diameter mounted co-axially on the cord with a pitch of 6.2mm (C-T-C) Bottom rail should be powder coated Aluminium flat bottom rail of 290 gm to finish it from the ends it should have rail end caps. The clutch will be at the tube. The return end cap bracket shall incorporate snap spring design to facilitate easy installation and removal for maintenance activities. The bracket shall be finished with a flush mounting cover on each side providing an aesthetic finish. It should handle up to 5 Kgs of material. The clutch should mount flush to the face of the bracket which minimize the light gap between the shade and the window frame. Complete in all respect as per the direction of Architect/Engineer-in-charge. |
503 | Door hardware |
504 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
505 | 250x10 mm |
506 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
507 | 300x16 mm |
508 | Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of 5 mm (± 0.2 mm), made out of single piece extruded PVC profile, with mitred cut joints and joint with 2 nos of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40x20 mm M.S. rectangular tube of 0.8 mm , including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8 x100 mm long anchor fasteners complete, all as per manufacturer"s specification and direction of Engineer -in- charge. |
509 | 35 mm thick factory made Solid panel PVC Door shutter, made out of single piece extruded soild PVC profiles, 5 mm (± 0.2 mm) thick, having styles & rails (except lock rail) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power, including reinforcing with MS tube of size 40 mm X 20 mm x 1 mm, joints of styles & rails to be mitered cut & joint with the help of PVC solvent cement, self driven self tapping screws & M.S. rectangular pipes bracket of size 190 mm X 100 mm of cross section size 35 mm x 17 mm x 1 mm at each corner. Single piece extruded 5 mm thick solid PVC Lock rail of size 115 mm x 35 mm, out of which 75 mm to be flat and 20 mm to be tapered at both ends, having 15 mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125 mm x 11 mm, including providing 5 mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer"s specification and direction of Engineer-in-charge. |
510 | Decorative finish (wood grained finish) |
511 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required in stringers, treads, landings etc. of stair cases, Railing including use of chequered plate wherever required, all complete. |
512 | Providing and fixing 1mm thick M.S. Sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces |
513 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rustfree, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling,C.P. brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) : |
514 | For fixed portion |
515 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
516 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
517 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
518 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
519 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
520 | Filling the gap in between aluminum frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5mm depth and 5 mm width |
521 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315 , having brand logo embossed on the body/ plate with double spring mechanism and door weight upto 125 Kg., for doors including cost of cutting floors ,embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete. With stainless steel cover plate minimum 1.25 mm thickness |
522 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Wedge expansion type Fastener with threaded dia 12 mm |
523 | Providing and fixing 18 mm thick Granite (gang saw cut), mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high glossy finish etc. complete at all levels. |
524 | Granite stone of any colour and shade |
525 | (a) Slab area upto 0.50 Sqm |
526 | (b) Slab area Above 0.50 Sqm |
527 | Providing and laying rectified Glazed/Matt Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. |
528 | Providing and fixing Ist quality rectified ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
529 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
530 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
531 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
532 | Double charge vitrified tile polished finish of size |
533 | Size of Tile 600 x 600 mm |
534 | Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge |
535 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
536 | Providingedgemouldingto18mmthickGranitestone, includingmachinepolishingtoedgetogivehighgloss finish etc. complete as per design approved by Engineer-in- Charge.Granite Work |
537 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
538 | Note:- All Plaster work will carried out with prevention of surface cracks appearing between junctions of column/beam and walls, 150 mm wide chicken wire mesh should be fixed with U nails 150 mm centre to centre before plastering the junction. The plastering of walls and beam/column in one vertical plane should be carried out in one go. For providing and fixing chicken wire mesh with U nails nothing shall be paid extra. |
539 | 12 mm cement plaster of mix (with fine sand): |
540 | 1:4 (1 cement: 4 fine sand) |
541 | 15 mm cement plaster on rough side of single or half brick wall of mix : (with coarse sand): |
542 | 1:6 (1 cement: 6 coarse sand) |
543 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement: 3 coarse sand) finished rough with sponge. |
544 | 6 mm cement plaster of mix : |
545 | 1:3 (1 cement : 3 fine sand) |
546 | 12 mm cement plaster finished with a floating coat of neat cement of mix : |
547 | 1:4 (1 cement: 4 fine sand) |
548 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
549 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including base perparation with cement based putty & applying additional coats wherever required to achieve even shade and colour. |
550 | Finishing walls with textured exterior paint of required shade New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm including base perparation with cement based putty & applying additional coats wherever required to achieve even shade and colour. |
551 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
552 | Two or more coats on new work |
553 | Stone work, plain in copings, cornices, string courses and plinth courses,upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. |
554 | White sand stone |
555 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: |
556 | (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. |
557 | (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
558 | (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. |
559 | (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. |
560 | (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : |
561 | With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
562 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : |
563 | (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. |
564 | (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonrywith polymer mixed slurry. |
565 | Providing and laying broken AAC Block in sunken portion of W.C. & kitchen. These broken Block mixed with cement mortar 1:8 ( 1 cement : 8 coarse sand) laid and compacted properly including supply of labour, material, and tools and plant etc. as per instruction of Engineer-in-charge. |
566 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
567 | In 75 x75 mm deep chase |
568 | Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. |
569 | Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
570 | 100 mm dia (OD-120 mm & ID-103 mm nominal) |
571 | 200 mm dia (OD-120 mm & ID-103 mm nominal) |
572 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. |
573 | 300 mm dia |
574 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : |
575 | Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
576 | Providing & fixing in position 1000 mm wide , Electrical Insulating Rubber Mats as per IS 15652:2006, 2 mm thick, suitable up to 1.1 KV , fire retardant, no effect of acids, alkalis and transformer oils, moisture proof, high tensile strengthandtexture finish / cloth impression (Anti slip , marking on top) |
577 | Electrical |
578 | Wiringpointforlightwith1.5sq.mm.FRLSHPVC insulatedmultistrandsingle core copper conductor cable inheavyguageinPVCconduitpartlyconcealedinthe wallandpartlylaidinslabalongwiththereinforcement beforeconcreting,completewith 1.5 sq.mmFRLSH PVC insulated multistrand copper conductorearth continuity wire drawn inside,GP Box, Modular type switch&ceilingrose/angle/battenholderon3mmthick phenolicpaminatedbackalitesheetetccompleteinall respect as directed including matching colour wash. |
579 | Wiringpointfortwowayslightwith1.5sq.mm.F.R. PVCinsulatedmultistrandsinglecorecopperconductor cableininsulatedmultistrandsinglecorecopper conductor cable in in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduitpartly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, GP Box and two number twonosmodulartypeswitch &ceilingrose/angle/ batten holder on 3 mm thick phanolic laminated backelite sheetetc.,complete inallrespect,asdirected,including matching colour wash. |
580 | Wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single corecopperconductorcablePVCconduitwith1.5sq. mm.FRLSHPVCinsulatedmultistrandcoppercableas earthwiredrawninsidetheconduit.,GPBox,modular type switch & ceiling rose on 3 mm. thick backelite etc., complete in all respect including matchingwash. |
581 | Wiring point for 5A plug with 1.5 sq. mm.FRLSH PVC insulatedmultistrandsingle core copper conductor cable inPVCconduitwith1.5mm.FRLSHPVCinsulated multistrand copper sq. cable as earthwire drawn inside the conduit concealed in wall and partly laid in slab alongwith the reinforcement before concreting,and modulartypeswitchandsocketetc.,completeinall respect including matching colour wash. |
582 | SupplyandfixingofdoorchimeonpolishedMDFEG /Teak ply board including making connections etc. complete in all respect. |
583 | Wiringpointforexhaustfanwith1.5sq.mm.FRLSH PVCinsulatedmultistrandsinglecorecopperconductor cableinPVCconduitwith1.5sq.mm.FRLSHPVC insulated multistrand copper conductor cable as earthwire drawninsidetheconduitpartlyconcealedinwalland partlylaidinslabalongwiththereinforcementbefore concreting,completewithGPBox,15Aswitchtype switch & ceiling rose on 3 mm thick phenolic laminated backelitesheetetc.,completeinallrespectincluding matching colour wash. |
584 | Supply and fixing hexagonal/Round G.P.fan box of approvedmakemadeupof1.0mmthickISIMarked G.P.sheet spot welded Four to Eight holes of 25.4 mm for pipeentryofthebox.Holesshouldbesemi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwedfittedwith300mmroundzinkcotedM.S Bar X 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work. |
585 | Wiring point for call bell with 1.5 sq. mm. FRLSH PVC insulated multistrand single core copper conductor cablen PVCconduitwith1.5sq.mm.FRLSHPVCinsulated multistrandcopperconductorcableasearthwiredrawn inside the conduit. partly concealed in wall and partly laid inslabalongwiththereinforcementbeforeconcreting completeGPBoxandmodulartypebellpushor2pin socket etc, |
586 | Supply and fixing of power plug with 15A/250 volt flush typeswitchand5pin15A/250Vflushtypeuniversal socket in suitable M.S. box of 175mm x 100mm x 50mm sizewithphenoliclaminatedbakelitesheetcover3mm thick fixed with brass machine screw and cup washer. |
587 | Supply and fixing of power plug with 20Amp./250 volt flush type modular switch and 5 pin 20 A/250 volt flush typeuniversalmodularsocketswitchonconcealedM.S boxincludingsupplyofallmaterial,labourT&Petc. required for proper completion of work. |
588 | S/f of Call Bell |
589 | S/o Invertor wiring Point for Light/Fan/Plug with 1.5mm Copper wire |
590 | S/f of Electronics Fan Regulator moduler type |
591 | Wiring point for fan /fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulatedmultistrandsingle core copperconductor cableinheavyguagerigidsteel conduitpipeonsurfacecompletewith14 SWG copper earth continuity wire, modular type switch & ceiling rose on 3 mm. thick phenolic laminated backelite sheet etc, complete in all respect. |
592 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
593 | 1 or 2 Module |
594 | 3 Module |
595 | 4 Module |
596 | 6 Module |
597 | 8 Module |
598 | Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. |
599 | 5/6 amps switch |
600 | 3 pin 5/6 amp socket outlet |
601 | Telephone socket outlet |
602 | TV antenna socket outlet |
603 | Supply andfixingandconcealingofPVC conduit pipe with ISI mark embossed and with PVCaccessoriesconfirming to IS No. 3419for drawing wires accessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin / adhesive to makethecompletepipingrigid,plasteringwithcement sandmortarfinishedtothelevelwithmatchingcolour washincludingcostofallmateriallabourandT&Petc required for proper completion of the work as per directions and to the satisfaction of Engineer in charge. |
604 | 20mmdia.2mm thick PVC conduit |
605 | 25 mm dia 2 mm thick PVC conduit. |
606 | 32 mm dia 2 mm thick PVC conduit. |
607 | 40 mm dia 2 mm thick PVC conduit. |
608 | Supply and fixing of 2/3/4 ways round PVC junction box confirming to ISS PVC conduit concealed in wall, keeping its level upto plaster duly provided with propersizecover,screwedasdirectedatsitebythe EngineerI/Cwithsupply ofallthematerial,labourand T&P required for proper completion of work. |
609 | 20mmdia.2mm thick PVC conduit |
610 | 25 mm dia 2 mm thick PVC conduit. |
611 | 32 mm dia 2 mm thick PVC conduit. |
612 | 40 mm dia 2 mm thick PVC conduit. |
613 | Supply and wiring of submains with 2 nos. 2.5 sq.mm @ with 1 no. earth wire of 1.5 sq.mm FRLSH PVC insulated 1100 V grade single core multisranded copper conductor cable in existing PVC conduit complete , including supply of all material , labour and T & P etc. required for proper completion of the work as directed by Engineer in charge. |
614 | Supply and wiring of submain with two number 4 sq.mm. FRLSHPVCinsulated1100Vgrademultistrandsingle core copper conductor cable in 20 mm dia heavy duty (2 mm thick) PVC conduit with one no. 2.5 sq. mm. FRLSH PVCinsulatedmultistrandcopperconductorcableas earth continuity wire drawn in conduit partly concealed in walland partlylaid in slab alongwith reinforcement beforeconcreting,including matchingcolourwashetc. complete in all respect. |
615 | Supplyandwiringofsubmainwithtwonumber6sq. mm.FRLSHPVCinsulated1100Vgrademultistrand singlecorecopperconductorcablein25mmdiaheavy duty (2mmthick)PVCconduitwithonenumber4sq. mm. FRLSH PVC insulated multistrand copper conductor cableasearthcontinuitywiredrawninconduitpartly concealed in wall and partly laid in slab alongwith reinforcementbefore concreting including matching colour wash etc. complete in all respect. |
616 | Supply and wiring of 4 number 16 sq. mm. PVC insulated 1100Vgradesinglecore Copperconductorcablein40 mm dia PVC conduit partly concealed in wall and partly laidinslabalongwithreinforcementbeforeconcreting, with two number 10 sq mm single core Copper conductor cableasearthcontinuitywiredrawnincouditincluding matching colour wash etc, complete in all respect. |
617 | S/w of Submain FRLSH Insulated multistand copper cond cable in HG PVC Conduit pipe concealed in wall as follws 4 sqmm 4 wire |
618 | Supplyandwiringof4number6sq.mm.FRLSHPVC insulated1100Vgrademultistrandsinglecorecopper conductorcable in32mm diaheavy duty (2mm thick) PVC conduit with 2 nos 4 sq.mm.FRLSH PVC insulated multistrandcopperconductorcableasearthcontinuity wire drawn in conduit.partly concealed in wall and partly laidinslabalongwithreinforcementbeforeconcreting including matching colour wash etc, completeinall respect. |
619 | Supply and wiring of 4 number 10 sq. mm. FRLSHPVC insulated1100Vgrademultistrandsinglecorecopper conductor cable in heavy duty (2 mm thick) PVC conduit with2 nos6sq.mm.FRLSHPVCinsulatedcopper conductor cable as earth continuity wire drawn in conduit.partlyconcealedinwallandpartly laidinslab alongwith reinforcement before concreting including matching colour wash etc, complete in all respect. |
620 | S&F surface/flush mounting 8ways SPN distribution boardwith additional metal doorwithoutMCB complete in all respect, as directedbyEngineer in charge. |
621 | S & F surface/Flush mounting 12 ways SPN distribution board withadditionalmetaldoor withoutMCB completeinall respect, asDirect by Engineer in Charge. |
622 | S&Fsurface/Flushmounting6waysTPNdistributionboard without additional board without MCB complete in all respect, as directed at site byEngineer in charge. |
623 | S&Fsurface/Flushmounting8waysTPNdistributionboard without additional door without MCB complete in all respect,as directed at site byEngineer in charge. |
624 | S & Fsurface/Flush mounting 12ways TPNdistribution board with additional metal door without MCB complete in all respect,as directed at site byEngineer in charge. |
625 | S & F surface/Flush mounting 4ways V TPN distribution board withadditionalmetaldoor withoutMCB completeinall respect,as directed at site byEngineer in charge. |
626 | S & F surface/Flush mounting 6ways VTPN distribution board withadditionalmetaldoor withoutMCB completeinall respect,as directed at site byEngineer in charge. |
627 | S & F surface/Flush mounting 8waysV TPN distribution board with additional metal board without MCB complete in all respect. |
628 | S&F of 6 Amp. to 32Amp. 4 pole MCB (10 KA) C Curve CAT-A |
629 | S&F of 40 Amp. 4 pole MCB (10 KA) CAT-A |
630 | S/f of 63A/4 Pole MCB CAT-A |
631 | S&F of6 Amp. to 32Amp. DP MCB (10 KA) C Curve CAT-A |
632 | S&F of 40Amp. DP MCB (10 KA) C Curve CAT-A |
633 | S&F of 63Amp. DP MCB (10 KA) CAT-A |
634 | S/f of 6 to 32 A MCB C-Type |
635 | S&Fandmakingconnectionof25A2pole30mAELCB/ RCCBofDinRailMountingcompleteinallrespectasper direction and satisfaction to the Engineer in charge. |
636 | S&Fandmakingconnectionof40A2pole30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge. |
637 | S&Fandmakingconnectionof63A2pole30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge. |
638 | S & F sheet steel enclosure for S.P/ D.P. MCB with neutral link and earth terminal. |
639 | S & F sheet steel enclosure for T.P./Four PoleMCB. |
640 | S&F single pole MCB blanking plate |
641 | SupplyandlayingofaluminiumconductorPVC insulatedarmouredservedsheathedcables1100Volts gradeatadepthof750mmbelowgroundlevelovera cushionof75mm.thicksandallaroundandprotected with burnt bricks on sides and on top. On surface the cable run shall be fixedon M.S. clamps etc. of suitable size or asdirectedbytheEngineer-Incharge, completeinall respect.Thearmouringofthecableshallbeproperly connected with the earth conductor by clamps etc. |
642 | 35 sq. mm 3-1/2 core |
643 | 50 sq. mm 3-1/2 core |
644 | 70 sq. mm 3-1/2 core |
645 | 95 sq. mm 3-1/2 core |
646 | 120 sq. mm 3-1/2 core |
647 | 150 sq. mm 3-1/2 core |
648 | 185 sq. mm 3-1/2 core |
649 | 240 sq. mm 3-1/2 core |
650 | 300 sq. mm 3-1/2 core |
651 | Supplyandfixingofbrassnickleplatedcompression glandforPVCinsulated&armouredservedsheathed, undergroundcable including rubber ring etc.complete in all respect. The armouring of the cable shall be properly connectedwiththeearthasperdirectionofEngineer- Incharge. |
652 | 16 sq. mm 2 core |
653 | 4 sq. mm 3 core |
654 | 6 sq. mm 3 core |
655 | 4 sq. mm 4 core |
656 | 6 sq. mm 4 core |
657 | 10 sq. mm 4 core |
658 | 16 sq. mm 4 core |
659 | 25 sq. mm 3-1/2 core |
660 | 35 sq. mm 3-1/2 core |
661 | 50 sq. mm 3-1/2 core |
662 | 70 sq. mm 3-1/2 core |
663 | 95 sq. mm 3-1/2 core |
664 | 120 sq. mm 3-1/2 core |
665 | 150 sq. mm 3-1/2 core |
666 | 185 sq. mm 3-1/2 core |
667 | 240 sq. mm 3-1/2 core |
668 | 300 sq. mm 3-1/2 core |
669 | Supplying following 1.1kV grade, heavy duty XLPE insulated, FRLS type armoured /Unarmured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete as required. |
670 | 3.5C x 185 sqmm aluminium conductor, A2XWY. |
671 | 3.5C x 120 sqmm aluminium conductor, A2XWY. |
672 | 3.5C x 95 sqmm aluminium conductor, A2XWY. |
673 | 3.5C x 70 sqmm aluminium conductor, A2XWY. |
674 | 3.5C x 50 sqmm aluminium conductor, A2XWY. |
675 | 3.5C x 35 sqmm aluminium conductor, A2XWY. |
676 | 4C X 25 sqmm copper conductor, 2XWY |
677 | 4C X 16 sqmm copper conductor, 2XWY |
678 | 4C X 16 sqmm copper conductor, 2XY |
679 | 4C X 10 sqmm copper conductor, 2XWY |
680 | 4C X 6 sqmm copper conductor, 2XY |
681 | 4C X 4 sqmm copper conductor, 2XY |
682 | 3C X 10 sqmm copper conductor, 2XWY |
683 | 3C X 6 sqmm copper conductor, 2XWY |
684 | 3C X 4 sqmm copper conductor, 2XY |
685 | 1C X 16 sqmm copper conductor, 2XY |
686 | 1C X 10 sqmm copper conductor, 2XY |
687 | 2C X 6 sqmm copper conductor, 2XY |
688 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. |
689 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
690 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
691 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
692 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
693 | Supply, installation, testing and commissioning of indoor floor mounted/ wall mounted, IP42, factory built, modular, sectionalised, compartmentalized, extendable type LT cubicle panel of suitable size suitable for operation on 433/415 volts, 50 Hz AC 3 phase 4 wire supply system fabricated from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates with stiffeners wherever required, having vibration free structure chemically treated with seven tank process or better before painting for surface treatment and powder coated in approved shade, with suitable electrolytic grade high conductivity bus bars extensible, DMC/ SMC (whichever is superior) bus bar supports, with short circuit withstand capacity as mentioned ,bottom base channel of section not less than 100mmX 50mmX 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm. PVC insulated FRLS copper conductor S/C cable for voltage & current respectively, including providing and fixing following switch gears and as per schedules ,technical specifications etc.complete as required. |
694 | Main Panel |
695 | Incomer : |
696 | MCCB 415V, 50Hz, 100A, 4P, 25kA for 1 sec rated microprocessor based MCCB with inbuilt LSIG protection- 1 Nos. |
697 | Metering (1 No.) Multifunction meter with inbuilt selector switch for measurement of current, voltage, power factor, KVA, kVAh, KVArh, KVAR, frequency, ,KWHr (both line and phase) complete as per specifications |
698 | Indication lamps LED type phase indication lamps suitable for 230V,50Hz AC (red, yellow, blue) - 1 Set. LED type Indication lamps for breaker, suitable for 230V,50Hz AC supply (on, off, trip) - 1 set |
699 | CTs: 415V ,100/5A, 15VA, CL-1 current transformer for metering |
700 | Busbar : |
701 | Busbar (1 Set - 4P + E) Busbar made up of electrolytic grade high conductivity aluminium in rectangular cross section and suitable for 415V, FP, 50 Hz, 200 A, 25 kA for 1 sec of required length and cross sectional area. |
702 | Outgoing : |
703 | Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
704 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
705 | 200 mm dia (OD-200 mm & ID-175 mm nominal) |
706 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. |
707 | 100 mm dia |
708 | 300 mm dia |
709 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
710 | Providing & making of inspection man hole chambers offollowing size as detailed below with 230 mm thick brick work plaster inside and outside both, PCC flooring including excavation, providing and fixing of heavy duty ISI mark SFRC cover with frame complete with RCC slab and complete as required per specifications or upto the satisfaction of engineer-in-charge. |
711 | 1000mm X 1000 mm(depth 1.200 mtr) - 230mm Thick |
712 | 800mm X 800 mm (depth 0.800 mtr) - 230mm Thick |
713 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
714 | Providing & fixing in position 1000 mm wide, Electrical Insulating Mats, 2mm thick, suitable upto 1.1 KV grade including cutting to required length complete as required per specifications or upto the satisfaction of engineer-in-charge. |
715 | Supply & fixing in position approved shock treatment chart written in English Hindi and Local language.These charts shall be framed in wooden frame & covered with clear glass. |
716 | Supply of Tool & First Aid Box with all necessary tools for maintenance of electrical installation & First aid. |
717 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
718 | 100 mm width x 50 mm depth x 1.6 mm thickness |
719 | 150 mm width x 50 mm depth x 1.6 mm thickness |
720 | 300 mm width x 50 mm depth x 1.6 mm thickness |
721 | 450 mm width x 50 mm depth x 2 mm thickness |
722 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
723 | 100 mm width X 50 mm depth X 1.6 mm thickness |
724 | 150 mm width X 50 mm depth X 1.6 mm thickness |
725 | 300 mm width X 50 mm depth X 1.6 mm thickness |
726 | 450 mm width x 50 mm depth x 2 mm thickness |
727 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
728 | 100 mm width X 50 mm depth X 1.6 mm thickness |
729 | 150 mm width X 50 mm depth X 1.6 mm thickness |
730 | 300 mm width X 50 mm depth X 1.6 mm thickness |
731 | 450 mm width x 50 mm depth x 2 mm thickness |
732 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Cross member” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
733 | 100 mm width X 50 mm depth X 1.6 mm thickness |
734 | 150 mm width X 50 mm depth X 1.6 mm thickness |
735 | 300 mm width X 50 mm depth X 1.6 mm thickness |
736 | 450 mm width x 50 mm depth x 2 mm thickness |
737 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
738 | 100 mm width X 50 mm depth X 1.6 mm thickness |
739 | 150 mm width X 50 mm depth X 1.6 mm thickness |
740 | 300 mm width X 50 mm depth X 1.6 mm thickness |
741 | 450 mm width x 50 mm depth x 2 mm thickness |
742 | Supply andfixing of recess/Surface/Pendent mountinground6Watt8WattLEDDownLighter havingPowdercoateddiecastaluminiumhousing withheatsink,diffuser/Reflectoranddriverset complete in all respect. CAT-AAA |
743 | Supply and fixing ofrecess/ Surface/ Pendent mountinground 10to15WattLEDDownLighter havingPowdercoateddiecastaluminiumhousing with heatsink,diffuser/Reflectoranddriverset complete in all respect. CAT- AAA |
744 | Supply and fixing ofrecessmounting round 15 to 18 WattLED DownLighterhavingPowdercoated die castaluminiumhousingwith heatsink,diffuser/ Reflector and driver set complete in all respect. CAT- AAA |
745 | Supplyandfixingof36Wattto46Wattindoor Recess mounting LED Square Fitting for Armstrong CeilinghavingPowdercoateddiecastaluminium housing body withextended heat sink and diffuser of SpecialPolycarbonatemeterialanddriverset complete in all respect. CAT-AAA |
746 | SupplyandfixingofLEDTubeLightwithbatten suitable forupto1X 22watt LED tube lightfitting includingtubeonSurfacecompleteinallrespect. CAT-AAA |
747 | Supply and fixing ofwater tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection . complete in allrespect. CAT-AAA |
748 | Supply & Fixing of40WattLED Surface Mounting weatherproof Luminaire with PCHousing andopal finishcoverconfirmingtoIP65Completeinall respect. CAT-AAA |
749 | Erection andtestingofexhaustfanontheexistinghole withsuitablesizeofragbolts,nutsandwashersetc., complete in all respect. |
750 | Erectionandtestingofceilingfanandregulatoretc. excluding supply of down rod, complete in all respect. |
751 | Cost of 1200mm Ceilling Fan sweep |
752 | Cost of 300mm Ex-Fan Fan |
753 | Supply and fixing of batten / angleholder complete in all respect. |
754 | Supply, installation, connections,testing & commissioning of 2 KVA inverter with minimum 90 minutes battery backup complete with suitable arrangement for placeing maintenance free batteries and inverter with connecting power input and inverter to batteries complete as per site requirement and full satisfaction of engineer incharge. |
755 | Supply, installation, connections,testing & commissioning of 3 KVA inverter with minimum 90 minutes battery backup complete with suitable arrangement for placeing maintenance free batteries and inverter with connecting power input and inverter to batteries complete as per site requirement and full satisfaction of engineer incharge. |
756 | Plumbing work |
757 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
758 | W.C. pan with ISI marked white solid plastic seat and lid each 6941.30 |
759 | Providing and fixing SS316 grab bar600 mm long complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. RA816671001(Roca make or equalant) |
760 | Providing and fixing Health faucet with 1 metre long Flexible Tube andCP wall hook with PVC & SS Screwswherever required complete as directed by the Engineer-in-charge |
761 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required |
762 | Kitchen sink with drain board (Single bowl depth 250 mm) |
763 | Providing, Fixing of CP Brass sink mixer for kitchen sink with wall flange, extended operating lever, swinging spout and surgical purpose handle complete with all accessories as required and making good the walls wherever required. |
764 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
765 | Providing and Fixing 15 mm nominal bore CP Brass Piller cock of approved quality conforming to IS Standards etc. complete in all respect as per direction of Engineering-in-charge.(In the bathroom for wash basin). |
766 | Providing and Fixing 15 mm nominal bore CP Brass bib cock of approved quality conforming to IS Standards etc. complete in all respect as per direction of Engineering-in-charge. |
767 | Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112 mm distance from wall of standard shape withbracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. ) |
768 | Providing and fixing CP Brass Bottle Trap of approved quality & make etc. complete in all respect as per direction of Engineering-in-charge. |
769 | 32 mm dia |
770 | Providing and fixing C.P. brass angle valveof approved quality conforming to IS:8931 etc. complete in all respect as per direction of Engineering-in-charge. 15mm nominal bore |
771 | Providing and FixingC.P. Brass Toilet paper holder,including cuttingand making good the walls wherever required etc. complete in all respect as per direction of Engineering-in-charge. |
772 | Providing and Fixing Over head Rain shower 203mm including all diverter and mixing valves & all cp fittings Make : Kohler, Model: 73199IN-CP |
773 | Providing and fixing vertical or horizontal storage type hot water heater fixed to wall with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non-return valve complete including making connections with 15mm dia CP connecting pipes on inlet and outlet, suitable length of power cable and 15 amps plug . |
774 | 15 Literfor canteen |
775 | 25 Litre |
776 | Supplying, fixing, testing and commissioning of approved make ELECTRIC HAND DRIER twin blower integrated with timer (0-3 minutes) and infrared arrangement. The drier shall be fully automatic. |
777 | Providing and Fixing Over head Rain shower 203mm including all diverter and mixing valves & all cp fittings |
778 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
779 | W.C. pan with ISI marked white solid plastic seat and lid each 6941.30 |
780 | Providing and fixing SS316 grab bar600 mm long complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. RA816671001(Roca make or equalant) |
781 | Providing and fixing Health faucet with 1 metre long Flexible Tube andCP wall hook with PVC & SS Screwswherever required complete as directed by the Engineer-in-charge |
782 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required |
783 | Kitchen sink with drain board (Single bowl depth 250 mm) |
784 | Providing, Fixing of CP Brass sink mixer for kitchen sink with wall flange, extended operating lever, swinging spout and surgical purpose handle complete with all accessories as required and making good the walls wherever required. |
785 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
786 | Providing and Fixing 15 mm nominal bore CP Brass Piller cock of approved quality conforming to IS Standards etc. complete in all respect as per direction of Engineering-in-charge.(In the bathroom for wash basin). |
787 | Providing and Fixing 15 mm nominal bore CP Brass bib cock of approved quality conforming to IS Standards etc. complete in all respect as per direction of Engineering-in-charge. |
788 | Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112 mm distance from wall of standard shape withbracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. ) |
789 | Providing and fixing CP Brass Bottle Trap of approved quality & make etc. complete in all respect as per direction of Engineering-in-charge. |
790 | 32 mm dia |
791 | Providing and fixing C.P. brass angle valveof approved quality conforming to IS:8931 etc. complete in all respect as per direction of Engineering-in-charge. 15mm nominal bore |
792 | Providing and FixingC.P. Brass Toilet paper holder,including cuttingand making good the walls wherever required etc. complete in all respect as per direction of Engineering-in-charge. |
793 | Providing and Fixing Over head Rain shower 203mm including all diverter and mixing valves & all cp fittings Make : Kohler, Model: 73199IN-CP |
794 | Providing and fixing vertical or horizontal storage type hot water heater fixed to wall with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non-return valve complete including making connections with 15mm dia CP connecting pipes on inlet and outlet, suitable length of power cable and 15 amps plug . |
795 | 15 Literfor canteen |
796 | 25 Litre |
797 | Supplying, fixing, testing and commissioning of approved make ELECTRIC HAND DRIER twin blower integrated with timer (0-3 minutes) and infrared arrangement. The drier shall be fully automatic. |
798 | Providing and Fixing Over head Rain shower 203mm including all diverter and mixing valves & all cp fittings |
799 | Providing and fixing soil, waste and vent pipes : |
800 | 100 mm dia |
801 | Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 |
802 | Providing and Fixing M.S. Holder bat clamp (factory manufactured) of approved design to sand cast iron / cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5 mm flat of specified shape, projecting 75 mm outside the wall surface and fixed on wall with 4 Nos, 6 mm diameter expansion hold fasteners including drilling necessary holes in brick wall /CC/RCC surface and the cost of bolts etc. . The pipes shall be fixed to the already fixed brackets with the help of 30 mmx1.60 mm galvanized M.S. flats of specified shape and total length 420 mm and shall be fixed with M.S. nuts, bolts and washers of size 25x6 mm, one bolt on each side of the pipe. |
803 | Total bracket length 580 mm of approved shape and design, (for single 100 mm dia pipe) |
804 | Total bracket length 810 mm of approved shape and design, (for single 100 mm dia pipe) |
805 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. |
806 | 100 mm dia |
807 | Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
808 | Providing and fixing plain bend of required degree. |
809 | 100 mm dia |
810 | Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 |
811 | Providing and fixing single equal plain junction of required degree : |
812 | 100x100x100 mm |
813 | Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
814 | Providing and fixing double equal plain junction of required degree. |
815 | 100x100x100x100 mm |
816 | Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 |
817 | Providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete : |
818 | 100 mm |
819 | Sand cast iron S&S as per IS - 3989 |
820 | Providing and Fixing 100 mm dia Terminal guard for Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
821 | 100 mm |
822 | Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
823 | Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe |
824 | 100 mm dia |
825 | SS 304 grade coupling with EPDM rubber gasket |
826 | Providing and fixing M.S. stays and clamps for sand cast iron hubless pipes of diameter: |
827 | 100mm |
828 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : |
829 | 100 mm inlet and 100 mm outlet |
830 | Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
831 | Providing and FixingG.I. Reducing elbow (Floor drain) of 100 x 50 mm in cement concrete 1:2:4 at all levels for floor drains (excluding cost of grating) for connection to floor traps in sunken portions, complete as perdrawings and as per approval of the engineer-in-charge. |
832 | Providing and fixing on wall face unplasticised Rigid uPVC rain water pipes including couplerconforming to I.S:4985of 6 Kg/cm2 |
833 | 160 MM Diameter |
834 | Providing and Fixing to the inlet mouth of rain water pipe SS 304 grating of following diameter complete in all respects as per direction of the engineer-in-charge |
835 | a) For 160 mm dia |
836 | Providing and FixingG.I. "C" class pipe complete with G.I. Fittings and clamps, including cutting and making good the walls etc.(Internal work) |
837 | a)32 mm dia |
838 | b)40 mm dia |
839 | Painting of G.I. Pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality. |
840 | a)32 mm dia |
841 | b)40 mm dia |
842 | Providing and fixing G.I. Inlet fittings with maximum 3 inlets 32,40 & 50 mm size fabricated from 100 mm dia G.I. pipes and welded G.I. sockets, fixed to C.I. Trap with joints and set in cement concrete(1:2:4)complete as directed by Engineer-in-charge. |
843 | Providing and Fixing SS 304 Grating with frame and SS Screws casted heavy 125 mm diacomplete as directed by Engineer-in-charge. |
844 | Providingand fixing castbrasscleanoutplug/ floor cleanout with suitableinsert keysfor opening,malethreaded joint withG.I. socketcaulked to spun soil pipe including cost of joint etc.completeas directed by Engineer-in-charge. |
845 | 100 mm dia |
846 | Making core cutting holes for C.I. Pipe of 100 mm dia. etc. in R.C.C. floors and roofs for passing C.I. pipe etc. and repairing the hole after insertion of C.I. pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
847 | Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer-in-charge. |
848 | Providing & fixing rain water `Khurras" size 300x300 mm required depth with lead flashing around the pipe with one piece lead sheet of 3 mm thick set on a layer of cold bitumen. |
849 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - exposed on wall |
850 | 25 mm nominal bore |
851 | 32mm nominal bore |
852 | 65 mm normal bore |
853 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. CONCEALED WORK, including cutting chases and making good the wall etc. |
854 | 15 mm nominal outer dia pipes |
855 | 20 mm nominal outer dia pipes |
856 | 25 mm nominal outer dia pipes |
857 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : |
858 | 25 mm dia |
859 | 32 mm dia |
860 | 65 mm dia |
861 | Providing and filling sand of grading zone v or coarser grade all-round the G.I. Pipe in external work |
862 | 65 mm dia pipe |
863 | Providing and fixing forged brass lever operated ball valve of full flow with forged brass ball (Machined to mirror smooth finsh with hard chrome plated) and spindle with setting and gland of superior quality having minimum working pressure of 16 kg/cm2 etc. complete in all respect. |
864 | 25 mm dia |
865 | 32 mm dia |
866 | Providing and fixing C.I butterfly valve, wafer end type class PN 1.6 as per I.S:13095 or BS:5155, including necessary nuts, bolts, gaskets etc., complete (flanges to be paid separately) |
867 | 65 mm dia |
868 | Supply, installation , testing & commissioning ofinsect vermin -proof coupling to vent pipes of underground tank/overhead tank with threaded or flanged joints, including M.S. flanges, nuts, bolts, 3mm thick rubber insertions complete. |
869 | 80mm nominal bore |
870 | Constructing masonrychamber 30x30x50 cm with FPS bricks, inside withbrick work in cement mortar1:4(1 cement: 4 Coarse sand) for stop cock, with C.I. surfacebox 100x100x75 mm(inside) with hinged cover fixed in cement concrete slab1:2:4 mix (1 cement: 2coarse sand:4gradedstone aggregate 20 mm nominal size) necessary excavationfoundation concrete 1:5:10 mix (1 cement : 5 fine sand and10graded stone aggregate 40 mm nominal size)and insideplastering withcementmortar1:3(1 cement: 3coarsesand) 12mm thickfinishedwitha floatingcoatofneatcement complete as per standard design. With common burnt clay FPS (non modular) bricks of class designation 7.5 |
871 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. |
872 | Providing and placing two tanks on mumty on polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
873 | Providing and placing two tanks on mumty on polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
874 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :: 150 x 100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
875 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with RCC Top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20mm nominal size) foundation concrete 1:4:8 mix ( 1 cement :4 coarse sand: 8 graded stone aggregate 40 nominal size), inside plastering 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand),finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design . Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (Heavy duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay FPS(non modular) bricks of class designation 7.5 |
876 | Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
877 | Cottage |
878 | Excavation in foundation in Ordinary soil (loamclay or sand) including lift upto 1.5m. And lead up to 30m. And including filling, watering and ramming of excavated earth into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the E.I.C. up to a distance of 30m. from the foundation trenches including all T&P phowarah and basket etc. complete. |
879 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
880 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8kM from the site of work and including watering dressing etc. Rate to include cost of all materila, labour and T&P etc. required for proper completion of the work. |
881 | Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge. |
882 | Providing & injecting chemical emulsion for Preconstructional anti-termite treatment and creating a chemical barrier under & around the column pits, wall trenches, basement excavation top surface of plinth filling junction of walls & floors,along the external perimeter ofbuilding expansion joints surrounding of pipes & coduits etc. complete plinth area of the building at ground floor only shall be measured as per I.S.6313 (part II 1981) Aldrine emlsifiable concentrate or any other approved material such as Chloropyriphos or Heptrachier or Chlordance will beused. Therateof application ofchemicalemulsionshallbeasfollows: (I) Treatment for masonary & foundation 5litres/ sqm.(II) Back fill in immediate contact with foundation 7.5 litres / sqm(III) Treatment of top surface of plinth filling 5 litres/sqm . (IV) Treatment of junction of wall and floor 7.5litres/sqm.(V) Treatment of soil along external perimeterof building 7.50 litres/sqm.(VI) Treatment of soilunder Apron along external perimeter 5litres/sqm |
883 | Cement concrete with 4 cm guage approvedstone ballast, approved coarse sand and cement in the proportion of 4:2:1 including supply of materials, labour and T&P etc. required for proper completion of the work. |
884 | Same as item 279 above but 2cm guage stone grit. |
885 | Cement concrete with 4cm. Guage approved stone ballast, approved coarse sand and cement in the proportion of 8:4:1 including supply of all materials, labour and T&P etc. required for proper completion for the work. |
886 | Damp Proof Coarse |
887 | 20mm (3/4") thick Damp proof course with cement and approved coarse sand 1:2 with and including water proofing material as ordered by the E.I.C. in the proportion as specified by the manufacturers, including supply of all materials, labour, T&P etc. required for proper completion for the work and including proper curing and shuttering as necessary. |
888 | As in item 360 above but 2.5cm (1") thick damp proof course of cement concrete consisting of 1:1.5:3 on part cement 1.5 parts approved coarse sand and 3 parts approved 13mm graded stone grit and including water proofing materials as ordered by the E.I.C. in the proportion as specified by the manufacturers, including supply of all materials, labour, T&P etc. required for proper completion for the work and including proper curing and shuttering as necessary. |
889 | Same as item no. 361 but 4cm thick |
890 | painting on DPC with two coats of air blown bitumen 85/50 or 85/25 @ 1.7kg/sqm. Approx. including cost of fuel if any. |
891 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stoneaggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed andonsolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
892 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : |
893 | Foundations, footings, bases of columns, etc. for mass concrete |
894 | Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
895 | Suspended floors, roofs, landings, balconies and access platform |
896 | Shelves (Cast in situ) |
897 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
898 | Columns, Pillars, Piers, Abutments, Posts and Struts |
899 | Stairs, (excluding landings) except spiral-staircases with water proof ply 12mm thick |
900 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick |
901 | Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured). Suspended floors, roofs, landing, beams and balconies (Plan area to be measured) |
902 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. |
903 | (Note :- Cement content considered in this item is @ 330 kg/ cum.Excess/less cement used as per design mix is payable/recoverable separately). |
904 | All works upto plinth level |
905 | All works above plinth level upto floor V level |
906 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete for proper completion of the work and including supply of steel its wastage.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
907 | M-15 Sub Class (A) Brick work in 1:6 cement and sand of 1.25 fineness modulus mortar in foundation and plinth including supply of all materials, labour, T&P etc. required for proper completion of work. |
908 | As in item 302 to 307 above but in superstructure including necessary cutting and moulding of bricks and also including honey comb brick work, thickness of walls more than one brick and for extra labour to above items. |
909 | As in item no. 309 above but for one brick wall add for extra labour. |
910 | As in item no. 309 above but walls of half brick wall add for extra labour. |
911 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
912 | Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
913 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood |
914 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size). |
915 | Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge |
916 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
917 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
918 | Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). |
919 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.0 mm thick |
920 | Providing and fixing 6mm thick toughened glass complete in all respects as per direction of the Engineer-in-charge. |
921 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately). |
922 | Roller Blinds:-Providing and fixing Roller Blinds as per the approved sample comprising of screen Fabric comprising of 25% polyester, 75% PVC with openness factor of 5%.Fabric weight 410-465 G weight per sqm, Thickness 0.67 mm. Healthy/safety standard - Oekotex Standard 100.Yarn count 18-19/cm, having fire resistance standard – NFPA 701 Method 1:2004 GB 50222-1995 (B1).The tear resistance should be complying to ISO4674 & breaking resistance – warp: > 1850 N/5cm, Weft: > 1400 N/5cm haing tear resistance of warp: > 135N and Weft: > 105N. Color fastness to Light 6-7/8(ISO 105 B02:1994).The Roller blind system consists of 38mm OD extruded out of Aluminium alloy 6063 T6 with silver anodized to provide an everlasting finish and luster, the rotary unit shall be 36mm in OD incorporating a clutch mechanism composed of low – flexing braided polyester cord with nylon core, Control Ball chain shall be composed of braided nylon cord (2mm dia) with high engineering grade plastic beads of 4.5mm diameter mounted co-axially on the cord with a pitch of 6.2mm (C-T-C) Bottom rail should be powder coated Aluminium flat bottom rail of 290 gm to finish it from the ends it should have rail end caps. The clutch will be at the tube. The return end cap bracket shall incorporate snap spring design to facilitate easy installation and removal for maintenance activities. The bracket shall be finished with a flush mounting cover on each side providing an aesthetic finish. It should handle up to 5 Kgs of material. The clutch should mount flush to the face of the bracket which minimize the light gap between the shade and the window frame. Complete in all respect as per the direction of Architect/Engineer-in-charge. |
923 | Door hardware |
924 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
925 | 250x10 mm |
926 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
927 | 300x16 mm |
928 | Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of 5 mm (± 0.2 mm), made out of single piece extruded PVC profile, with mitred cut joints and joint with 2 nos of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40x20 mm M.S. rectangular tube of 0.8 mm , including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8 x100 mm long anchor fasteners complete, all as per manufacturer"s specification and direction of Engineer -in- charge. |
929 | 35 mm thick factory made Solid panel PVC Door shutter, made out of single piece extruded soild PVC profiles, 5 mm (± 0.2 mm) thick, having styles & rails (except lock rail) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power, including reinforcing with MS tube of size 40 mm X 20 mm x 1 mm, joints of styles & rails to be mitered cut & joint with the help of PVC solvent cement, self driven self tapping screws & M.S. rectangular pipes bracket of size 190 mm X 100 mm of cross section size 35 mm x 17 mm x 1 mm at each corner. Single piece extruded 5 mm thick solid PVC Lock rail of size 115 mm x 35 mm, out of which 75 mm to be flat and 20 mm to be tapered at both ends, having 15 mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125 mm x 11 mm, including providing 5 mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer"s specification and direction of Engineer-in-charge. |
930 | Decorative finish (wood grained finish) |
931 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required in stringers, treads, landings etc. of stair cases, Railing including use of chequered plate wherever required, all complete. |
932 | Providing and fixing 1mm thick M.S. Sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces |
933 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps atjunctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rustfree, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling,C.P. brass / stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) : |
934 | For fixed portion |
935 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
936 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
937 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
938 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
939 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
940 | Filling the gap in between aluminum frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5mm depth and 5 mm width |
941 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315 , having brand logo embossed on the body/ plate with double spring mechanism and door weight upto 125 Kg., for doors including cost of cutting floors ,embeding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete. With stainless steel cover plate minimum 1.25 mm thickness |
942 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Wedge expansion type Fastener with threaded dia 12 mm |
943 | Providing and fixing 18 mm thick Granite (gang saw cut), mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high glossy finish etc. complete at all levels. |
944 | Granite stone of any colour and shade |
945 | (a) Slab area upto 0.50 Sqm |
946 | (b) Slab area Above 0.50 Sqm |
947 | Providing and laying rectified Glazed/Matt Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. |
948 | Providing and fixing Ist quality rectified ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
949 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick |
950 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
951 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
952 | Double charge vitrified tile polished finish of size |
953 | Size of Tile 600 x 600 mm |
954 | Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge |
955 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
956 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
957 | Providingedgemouldingto18mmthickGranitestone, includingmachinepolishingtoedgetogivehighgloss finish etc. complete as per design approved by Engineer-in- Charge.Granite Work |
958 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
959 | Note:- All Plaster work will carried out with prevention of surface cracks appearing between junctions of column/beam and walls, 150 mm wide chicken wire mesh should be fixed with U nails 150 mm centre to centre before plastering the junction. The plastering of walls and beam/column in one vertical plane should be carried out in one go. For providing and fixing chicken wire mesh with U nails nothing shall be paid extra. |
960 | 12 mm cement plaster of mix (with fine sand): |
961 | 1:4 (1 cement: 4 fine sand) |
962 | 15 mm cement plaster on rough side of single or half brick wall of mix : (with coarse sand): |
963 | 1:6 (1 cement: 6 coarse sand) |
964 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement: 3 coarse sand) finished rough with sponge. |
965 | 6 mm cement plaster of mix : |
966 | 1:3 (1 cement : 3 fine sand) |
967 | 12 mm cement plaster finished with a floating coat of neat cement of mix : |
968 | 1:4 (1 cement: 4 fine sand) |
969 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
970 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including base perparation with cement based putty & applying additional coats wherever required to achieve even shade and colour. |
971 | Finishing walls with textured exterior paint of required shade New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm including base perparation with cement based putty & applying additional coats wherever required to achieve even shade and colour. |
972 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
973 | Two or more coats on new work |
974 | Stone work, plain in copings, cornices, string courses and plinth courses,upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. |
975 | White sand stone |
976 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: |
977 | (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. |
978 | (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. |
979 | (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. |
980 | (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. |
981 | (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : |
982 | With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
983 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : |
984 | (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. |
985 | (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonrywith polymer mixed slurry. |
986 | Providing and laying broken AAC Block in sunken portion of W.C. & kitchen. These broken Block mixed with cement mortar 1:8 ( 1 cement : 8 coarse sand) laid and compacted properly including supply of labour, material, and tools and plant etc. as per instruction of Engineer-in-charge. |
987 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
988 | In 75 x75 mm deep chase |
989 | Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. |
990 | Demolishing R.C.C. work manually/ by mechanical means includingstacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
991 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
992 | In cement mortar |
993 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
994 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. |
995 | For thickness of tiles above 25 mm and up to 40 mm |
996 | Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
997 | 100 mm dia (OD-120 mm & ID-103 mm nominal) |
998 | 200 mm dia (OD-120 mm & ID-103 mm nominal) |
999 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. |
1000 | 300 mm dia |
1001 | Electrical Work |
1002 | Wiringpointforlightwith1.5sq.mm.FRLSHPVC insulatedmultistrandsingle core copper conductor cable inheavyguageinPVCconduitpartlyconcealedinthe wallandpartlylaidinslabalongwiththereinforcement beforeconcreting,completewith 1.5 sq.mmFRLSH PVC insulated multistrand copper conductorearth continuity wire drawn inside,GP Box, Modular type switch&ceilingrose/angle/battenholderon3mmthick phenolicpaminatedbackalitesheetetccompleteinall respect as directed including matching colour wash. |
1003 | Wiringpointfortwowayslightwith1.5sq.mm.F.R. PVCinsulatedmultistrandsinglecorecopperconductor cableininsulatedmultistrandsinglecorecopper conductor cable in in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduitpartly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, GP Box and two number twonosmodulartypeswitch &ceilingrose/angle/ batten holder on 3 mm thick phanolic laminated backelite sheetetc.,complete inallrespect,asdirected,including matching colour wash. |
1004 | Wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single corecopperconductorcablePVCconduitwith1.5sq. mm.FRLSHPVCinsulatedmultistrandcoppercableas earthwiredrawninsidetheconduit.,GPBox,modular type switch & ceiling rose on 3 mm. thick backelite etc., complete in all respect including matchingwash. |
1005 | Wiring point for 5A plug with 1.5 sq. mm.FRLSH PVC insulatedmultistrandsingle core copper conductor cable inPVCconduitwith1.5mm.FRLSHPVCinsulated multistrand copper sq. cable as earthwire drawn inside the conduit concealed in wall and partly laid in slab alongwith the reinforcement before concreting,and modulartypeswitchandsocketetc.,completeinall respect including matching colour wash. |
1006 | SupplyandfixingofdoorchimeonpolishedMDFEG /Teak ply board including making connections etc. complete in all respect. |
1007 | Wiringpointforexhaustfanwith1.5sq.mm.FRLSH PVCinsulatedmultistrandsinglecorecopperconductor cableinPVCconduitwith1.5sq.mm.FRLSHPVC insulated multistrand copper conductor cable as earthwire drawninsidetheconduitpartlyconcealedinwalland partlylaidinslabalongwiththereinforcementbefore concreting,completewithGPBox,15Aswitchtype switch & ceiling rose on 3 mm thick phenolic laminated backelitesheetetc.,completeinallrespectincluding matching colour wash. |
1008 | Supply and fixing hexagonal/Round G.P.fan box of approvedmakemadeupof1.0mmthickISIMarked G.P.sheet spot welded Four to Eight holes of 25.4 mm for pipeentryofthebox.Holesshouldbesemi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwedfittedwith300mmroundzinkcotedM.S Bar X 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work. |
1009 | Wiring point for call bell with 1.5 sq. mm. FRLSH PVC insulated multistrand single core copper conductor cablen PVCconduitwith1.5sq.mm.FRLSHPVCinsulated multistrandcopperconductorcableasearthwiredrawn inside the conduit. partly concealed in wall and partly laid inslabalongwiththereinforcementbeforeconcreting completeGPBoxandmodulartypebellpushor2pin socket etc, |
1010 | Supply and fixing of power plug with 15A/250 volt flush typeswitchand5pin15A/250Vflushtypeuniversal socket in suitable M.S. box of 175mm x 100mm x 50mm sizewithphenoliclaminatedbakelitesheetcover3mm thick fixed with brass machine screw and cup washer. |
1011 | Supply and fixing of power plug with 20Amp./250 volt flush type modular switch and 5 pin 20 A/250 volt flush typeuniversalmodularsocketswitchonconcealedM.S boxincludingsupplyofallmaterial,labourT&Petc. required for proper completion of work. |
1012 | S/f of Call Bell |
1013 | S/o Invertor wiring Point for Light/Fan/Plug with 1.5mm Copper wire |
1014 | S/f of Electronics Fan Regulator moduler type |
1015 | Wiring point for fan /fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulatedmultistrandsingle core copperconductor cableinheavyguagerigidsteel conduitpipeonsurfacecompletewith14 SWG copper earth continuity wire, modular type switch & ceiling rose on 3 mm. thick phenolic laminated backelite sheet etc, complete in all respect. |
1016 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
1017 | 1 or 2 Module |
1018 | 3 Module |
1019 | 4 Module |
1020 | 6 Module |
1021 | 8 Module |
1022 | Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. |
1023 | 5/6 amps switch |
1024 | 3 pin 5/6 amp socket outlet |
1025 | Telephone socket outlet |
1026 | TV antenna socket outlet |
1027 | Supply andfixingandconcealingofPVC conduit pipe with ISI mark embossed and with PVCaccessoriesconfirming to IS No. 3419for drawing wires accessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin / adhesive to makethecompletepipingrigid,plasteringwithcement sandmortarfinishedtothelevelwithmatchingcolour washincludingcostofallmateriallabourandT&Petc required for proper completion of the work as per directions and to the satisfaction of Engineer in charge. |
1028 | 20mmdia.2mm thick PVC conduit |
1029 | 25 mm dia 2 mm thick PVC conduit. |
1030 | 32 mm dia 2 mm thick PVC conduit. |
1031 | 40 mm dia 2 mm thick PVC conduit. |
1032 | Supply and fixing of 2/3/4 ways round PVC junction box confirming to ISS PVC conduit concealed in wall, keeping its level upto plaster duly provided with propersizecover,screwedasdirectedatsitebythe EngineerI/Cwithsupply ofallthematerial,labourand T&P required for proper completion of work. |
1033 | 20mmdia.2mm thick PVC conduit |
1034 | 25 mm dia 2 mm thick PVC conduit. |
1035 | 32 mm dia 2 mm thick PVC conduit. |
1036 | 40 mm dia 2 mm thick PVC conduit. |
1037 | Supply and wiring of submains with 2 nos. 2.5 sq.mm @ with 1 no. earth wire of 1.5 sq.mm FRLSH PVC insulated 1100 V grade single core multisranded copper conductor cable in existing PVC conduit complete , including supply of all material , labour and T & P etc. required for proper completion of the work as directed by Engineer in charge. |
1038 | Supply and wiring of submain with two number 4 sq.mm. FRLSHPVCinsulated1100Vgrademultistrandsingle core copper conductor cable in 20 mm dia heavy duty (2 mm thick) PVC conduit with one no. 2.5 sq. mm. FRLSH PVCinsulatedmultistrandcopperconductorcableas earth continuity wire drawn in conduit partly concealed in walland partlylaid in slab alongwith reinforcement beforeconcreting,including matchingcolourwashetc. complete in all respect. |
1039 | Supplyandwiringofsubmainwithtwonumber6sq. mm.FRLSHPVCinsulated1100Vgrademultistrand singlecorecopperconductorcablein25mmdiaheavy duty (2mmthick)PVCconduitwithonenumber4sq. mm. FRLSH PVC insulated multistrand copper conductor cableasearthcontinuitywiredrawninconduitpartly concealed in wall and partly laid in slab alongwith reinforcementbefore concreting including matching colour wash etc. complete in all respect. |
1040 | Supply and wiring of 4 number 16 sq. mm. PVC insulated 1100Vgradesinglecore Copperconductorcablein40 mm dia PVC conduit partly concealed in wall and partly laidinslabalongwithreinforcementbeforeconcreting, with two number 10 sq mm single core Copper conductor cableasearthcontinuitywiredrawnincouditincluding matching colour wash etc, complete in all respect. |
1041 | S/w of Submain FRLSH Insulated multistand copper cond cable in HG PVC Conduit pipe concealed in wall as follws 4 sqmm 4 wire |
1042 | Supplyandwiringof4number6sq.mm.FRLSHPVC insulated1100Vgrademultistrandsinglecorecopper conductorcable in32mm diaheavy duty (2mm thick) PVC conduit with 2 nos 4 sq.mm.FRLSH PVC insulated multistrandcopperconductorcableasearthcontinuity wire drawn in conduit.partly concealed in wall and partly laidinslabalongwithreinforcementbeforeconcreting including matching colour wash etc, completeinall respect. |
1043 | Supply and wiring of 4 number 10 sq. mm. FRLSHPVC insulated1100Vgrademultistrandsinglecorecopper conductor cable in heavy duty (2 mm thick) PVC conduit with2 nos6sq.mm.FRLSHPVCinsulatedcopper conductor cable as earth continuity wire drawn in conduit.partlyconcealedinwallandpartly laidinslab alongwith reinforcement before concreting including matching colour wash etc, complete in all respect. |
1044 | S&F surface/flush mounting 8ways SPN distribution boardwith additional metal doorwithoutMCB complete in all respect, as directedbyEngineer in charge. |
1045 | S & F surface/Flush mounting 12 ways SPN distribution board withadditionalmetaldoor withoutMCB completeinall respect, asDirect by Engineer in Charge. |
1046 | S&Fsurface/Flushmounting6waysTPNdistributionboard without additional board without MCB complete in all respect, as directed at site byEngineer in charge. |
1047 | S&Fsurface/Flushmounting8waysTPNdistributionboard without additional door without MCB complete in all respect,as directed at site byEngineer in charge. |
1048 | S & Fsurface/Flush mounting 12ways TPNdistribution board with additional metal door without MCB complete in all respect,as directed at site byEngineer in charge. |
1049 | S & F surface/Flush mounting 4ways V TPN distribution board withadditionalmetaldoor withoutMCB completeinall respect,as directed at site byEngineer in charge. |
1050 | S & F surface/Flush mounting 6ways VTPN distribution board withadditionalmetaldoor withoutMCB completeinall respect,as directed at site byEngineer in charge. |
1051 | S & F surface/Flush mounting 8waysV TPN distribution board with additional metal board without MCB complete in all respect. |
1052 | S&F of 6 Amp. to 32Amp. 4 pole MCB (10 KA) C Curve CAT-A |
1053 | S&F of 40 Amp. 4 pole MCB (10 KA) CAT-A |
1054 | S/f of 63A/4 Pole MCB CAT-A |
1055 | S&F of6 Amp. to 32Amp. DP MCB (10 KA) C Curve CAT-A |
1056 | S&F of 40Amp. DP MCB (10 KA) C Curve CAT-A |
1057 | S&F of 63Amp. DP MCB (10 KA) CAT-A |
1058 | S/f of 6 to 32 A MCB C-Type |
1059 | S&Fandmakingconnectionof25A2pole30mAELCB/ RCCBofDinRailMountingcompleteinallrespectasper direction and satisfaction to the Engineer in charge. |
1060 | S&Fandmakingconnectionof40A2pole30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge. |
1061 | S&Fandmakingconnectionof63A2pole30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge. |
1062 | SupplyandlayingofaluminiumconductorPVC insulatedarmouredservedsheathedcables1100Volts gradeatadepthof750mmbelowgroundlevelovera cushionof75mm.thicksandallaroundandprotected with burnt bricks on sides and on top. On surface the cable run shall be fixedon M.S. clamps etc. of suitable size or asdirectedbytheEngineer-Incharge, completeinall respect.Thearmouringofthecableshallbeproperly connected with the earth conductor by clamps etc. |
1063 | 35 sq. mm 3-1/2 core |
1064 | 50 sq. mm 3-1/2 core |
1065 | 70 sq. mm 3-1/2 core |
1066 | 95 sq. mm 3-1/2 core |
1067 | 120 sq. mm 3-1/2 core |
1068 | 150 sq. mm 3-1/2 core |
1069 | 185 sq. mm 3-1/2 core |
1070 | 240 sq. mm 3-1/2 core |
1071 | 300 sq. mm 3-1/2 core |
1072 | Supplyandfixingofbrassnickleplatedcompression glandforPVCinsulated&armouredservedsheathed, undergroundcable including rubber ring etc.complete in all respect. The armouring of the cable shall be properly connectedwiththeearthasperdirectionofEngineer- Incharge. |
1073 | 16 sq. mm 2 core |
1074 | 4 sq. mm 3 core |
1075 | 6 sq. mm 3 core |
1076 | 4 sq. mm 4 core |
1077 | 6 sq. mm 4 core |
1078 | 10 sq. mm 4 core |
1079 | 16 sq. mm 4 core |
1080 | 25 sq. mm 3-1/2 core |
1081 | 35 sq. mm 3-1/2 core |
1082 | 50 sq. mm 3-1/2 core |
1083 | 70 sq. mm 3-1/2 core |
1084 | 95 sq. mm 3-1/2 core |
1085 | 120 sq. mm 3-1/2 core |
1086 | 150 sq. mm 3-1/2 core |
1087 | 185 sq. mm 3-1/2 core |
1088 | 240 sq. mm 3-1/2 core |
1089 | 300 sq. mm 3-1/2 core |
1090 | Supplying following 1.1kV grade, heavy duty XLPE insulated, FRLS type armoured /Unarmured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete as required. |
1091 | 3.5C x 185 sqmm aluminium conductor, A2XWY. |
1092 | 3.5C x 120 sqmm aluminium conductor, A2XWY. |
1093 | 3.5C x 95 sqmm aluminium conductor, A2XWY. |
1094 | 3.5C x 70 sqmm aluminium conductor, A2XWY. |
1095 | 3.5C x 50 sqmm aluminium conductor, A2XWY. |
1096 | 3.5C x 35 sqmm aluminium conductor, A2XWY. |
1097 | 4C X 25 sqmm copper conductor, 2XWY |
1098 | 4C X 16 sqmm copper conductor, 2XWY |
1099 | 4C X 16 sqmm copper conductor, 2XY |
1100 | 4C X 10 sqmm copper conductor, 2XWY |
1101 | 4C X 6 sqmm copper conductor, 2XY |
1102 | 4C X 4 sqmm copper conductor, 2XY |
1103 | 3C X 10 sqmm copper conductor, 2XWY |
1104 | 3C X 6 sqmm copper conductor, 2XWY |
1105 | 3C X 4 sqmm copper conductor, 2XY |
1106 | 1C X 16 sqmm copper conductor, 2XY |
1107 | 1C X 10 sqmm copper conductor, 2XY |
1108 | 2C X 6 sqmm copper conductor, 2XY |
1109 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. |
1110 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
1111 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
1112 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
1113 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
1114 | Supply and burying of 600mm x 600mm x 3mm copper plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and two earthing lead of two no. 8 SWG copper wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and copper wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. complete in all respect. |
1115 | Supplyand fixingofhorizontalair termination(roof conductor)of25mmx3mmG.I.strip,G.I.clampson surface complete in all respects as approved by Engineer- in-charge. |
1116 | Supplyandfixingofverticalairterminationfinalrod comprising of 300mm long x 25mm dia. Copper rod with onepointedprongand100mmdiax3mmthickbase plate etc. complete in all respect. |
1117 | Supply and fixing of vertical down conductor of 32mm x 6mmG.I.stripetc.onapprovedclampsonsurfacefor lightningconductorcompleteinallrespects(fortwo storeyed Buildings). |
1118 | Supply and laying of 32 mm x 6 mm G.I. strip from earth electrodedirectlyinthegroundasrequiredcompletein all respect. |
1119 | Supply and laying of 32mm x 6mm copper strip from earth electrode directly in the ground as required complete in all respect. |
1120 | Supplyandfixingoftwonumber8SWGG.I.wirein 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. |
1121 | Supplyandfixingoftwonumber8SWG copperwirein 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. |
1122 | Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
1123 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
1124 | 200 mm dia (OD-200 mm & ID-175 mm nominal) |
1125 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. |
1126 | 100 mm dia |
1127 | 300 mm dia |
1128 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
1129 | Providing & making of inspection man hole chambers offollowing size as detailed below with 230 mm thick brick work plaster inside and outside both, PCC flooring including excavation, providing and fixing of heavy duty ISI mark SFRC cover with frame complete with RCC slab and complete as required per specifications or upto the satisfaction of engineer-in-charge. |
1130 | 1000mm X 1000 mm(depth 1.200 mtr) - 230mm Thick |
1131 | 800mm X 800 mm (depth 0.800 mtr) - 230mm Thick |
1132 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
1133 | Providing & fixing in position 1000 mm wide, Electrical Insulating Mats, 2mm thick, suitable upto 1.1 KV grade including cutting to required length complete as required per specifications or upto the satisfaction of engineer-in-charge. |
1134 | Supply & fixing in position approved shock treatment chart written in English Hindi and Local language.These charts shall be framed in wooden frame & covered with clear glass. |
1135 | Supply of Tool & First Aid Box with all necessary tools for maintenance of electrical installation & First aid. |
1136 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
1137 | 100 mm width x 50 mm depth x 1.6 mm thickness |
1138 | 150 mm width x 50 mm depth x 1.6 mm thickness |
1139 | 300 mm width x 50 mm depth x 1.6 mm thickness |
1140 | 450 mm width x 50 mm depth x 2 mm thickness |
1141 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
1142 | 100 mm width X 50 mm depth X 1.6 mm thickness |
1143 | 150 mm width X 50 mm depth X 1.6 mm thickness |
1144 | 300 mm width X 50 mm depth X 1.6 mm thickness |
1145 | 450 mm width x 50 mm depth x 2 mm thickness |
1146 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
1147 | 100 mm width X 50 mm depth X 1.6 mm thickness |
1148 | 150 mm width X 50 mm depth X 1.6 mm thickness |
1149 | 300 mm width X 50 mm depth X 1.6 mm thickness |
1150 | 450 mm width x 50 mm depth x 2 mm thickness |
1151 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Cross member” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
1152 | 100 mm width X 50 mm depth X 1.6 mm thickness |
1153 | 150 mm width X 50 mm depth X 1.6 mm thickness |
1154 | 300 mm width X 50 mm depth X 1.6 mm thickness |
1155 | 450 mm width x 50 mm depth x 2 mm thickness |
1156 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
1157 | 100 mm width X 50 mm depth X 1.6 mm thickness |
1158 | 150 mm width X 50 mm depth X 1.6 mm thickness |
1159 | 300 mm width X 50 mm depth X 1.6 mm thickness |
1160 | 450 mm width x 50 mm depth x 2 mm thickness |
1161 | Supply andfixing of recess/Surface/Pendent mountinground6Watt8WattLEDDownLighter havingPowdercoateddiecastaluminiumhousing withheatsink,diffuser/Reflectoranddriverset complete in all respect. CAT-AAA |
1162 | Supply and fixing ofrecess/ Surface/ Pendent mountinground 10to15WattLEDDownLighter havingPowdercoateddiecastaluminiumhousing with heatsink,diffuser/Reflectoranddriverset complete in all respect. CAT- AAA |
1163 | Supply and fixing ofrecessmounting round 15 to 18 WattLED DownLighterhavingPowdercoated die castaluminiumhousingwith heatsink,diffuser/ Reflector and driver set complete in all respect. CAT- AAA |
1164 | Supplyandfixingof36Wattto46Wattindoor Recess mounting LED Square Fitting for Armstrong CeilinghavingPowdercoateddiecastaluminium housing body withextended heat sink and diffuser of SpecialPolycarbonatemeterialanddriverset complete in all respect. CAT-AAA |
1165 | SupplyandfixingofLEDTubeLightwithbatten suitable forupto1X 22watt LED tube lightfitting includingtubeonSurfacecompleteinallrespect. CAT-AAA |
1166 | Supply and fixing ofwater tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection . complete in allrespect. CAT-AAA |
1167 | Supply & Fixing of40WattLED Surface Mounting weatherproof Luminaire with PCHousing andopal finishcoverconfirmingtoIP65Completeinall respect. CAT-AAA |
1168 | Erection andtestingofexhaustfanontheexistinghole withsuitablesizeofragbolts,nutsandwashersetc., complete in all respect. |
1169 | Erectionandtestingofceilingfanandregulatoretc. excluding supply of down rod, complete in all respect. |
1170 | Cost of 1200mm Ceilling Fan sweep |
1171 | Cost of 300mm Ex-Fan Fan |
1172 | Supply and fixing of batten / angleholder complete in all respect. |
1173 | Plumbing work |
1174 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
1175 | W.C. pan with ISI marked white solid plastic seat and lid each 6941.30 |
1176 | Providing and fixing Health faucet with 1 metre long Flexible Tube andCP wall hook with PVC & SS Screwswherever required complete as directed by the Engineer-in-charge |
1177 | Providing and Fixing White vitreous china Under counter wash basin with C.I. brackets painted white, 15 mm CP Brasspillar cock, 32mm dia. C.P. waste, C.P chain and rubber plug, C.P. connecting pipe to wall and C.P wall flange and rubber adapter for waste connection complete includingcutting and making goodthe wallswherever required etc. complete in all respect as per direction of Engineering-in-charge. |
1178 | Providing and Fixing 15 mm nominal bore CP Brass Piller cock of approved quality conforming to IS Standards etc. complete in all respect as per direction of Engineering-in-charge.(In the bathroom for wash basin). |
1179 | Providing and Fixing 15 mm nominal bore CP Brass bib cock of approved quality conforming to IS Standards etc. complete in all respect as per direction of Engineering-in-charge. |
1180 | Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112 mm distance from wall of standard shape withbracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. ) |
1181 | Providing and fixing CP Brass Bottle Trap of approved quality & make etc. complete in all respect as per direction of Engineering-in-charge. |
1182 | 32 mm dia |
1183 | Providing and fixing C.P. brass angle valveof approved quality conforming to IS:8931 etc. complete in all respect as per direction of Engineering-in-charge. 15mm nominal bore |
1184 | Providing and FixingC.P. Brass Toilet paper holder,including cuttingand making good the walls wherever required etc. complete in all respect as per direction of Engineering-in-charge. |
1185 | Providing and fixing vertical or horizontal storage type hot water heater fixed to wall with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non-return valve complete including making connections with 15mm dia CP connecting pipes on inlet and outlet, suitable length of power cable and 15 amps plug . |
1186 | 25 Litre |
1187 | Supply, installation , testing & commissioning of UPVC SWR Pipe (ring type) Class B and fittingfor soil , waste and vent pipe and Rain water downtake pipe conforming to IS:13592cuttorequiredlengths including door piece, bends, tee, y-tee, plain tee, door tee andall necessaryfittings and specials. Cost shall be inclusive of providing and Fixing of pipes and fittings at wall/ceiling level with all type of supported byMS hot dipped galvanised angle support for vertical and horizontal pipe fixing with GI u clamp & hangersetc. Makingproperconnectionwith cement solvent joint as per BIS / manufacturer.Cutting chases/holes in floors/walls/slab etc. The vertical downtake shall be supported with thrust block. Contractor shall submit support details for approval prior to execution of works at site. |
1188 | 110 mm dia |
1189 | Supply, installation , testing & commissioning of UPVC (Class III) Pipe of pressure rating 6 bar conforming to IS:4985cuttorequiredlengths includingall necessaryfittings and specials. Fixing at wall/ceiling level all type of supported byMS hot dipped galvanised angle support for vertical and horizontal pipe fixing with GI u clamp & hangersetc. Makingproperconnectionwith cement solvent joint as per BIS / manufacturer.Cutting chases/holes in floors/walls/slab etc. (For Rain Water) |
1190 | 40 mm dia |
1191 | 50 mm dia. |
1192 | Supply, installation , testing & commissioning in position UPVCFloor Trap of self cleaningdesign of following sizes for the embedded areas with minimum water seal of 50 mm. Making proper connection with. Cutting chase/ hole in floors /slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as required. including cost of cutting and making good the walls and floors where required. a) 110mm inlet and 110mm outlet. |
1193 | Supply, installation , testing & commissioning 110mm x 63mm UPVC wastereducing elbow (Floor drain) includingcutting chases, making holes inthe floor / slab, repairs complete as required and connection to pvc pipes. |
1194 | Supply, installation , testing & commissioning 3mm thick Heavy class SS gratingof approved design including setting in floor with cement motor to match with floor finish as per architect requirement suitable for FD and FT. a) Size 125 mm dia. |
1195 | Providing & fixing rain water `Khurras" size 450x450 mm required depth with lead flashing around the pipe with one piece lead sheet of 3 mm thick set on a layer of cold bitumen. Including Heavy duty CI/MS grating as per drawing complete as required. |
1196 | Supplying, installing, fixing, jointing, testing and commissioning ofapproved makeChlorinated Polyvinyl Chloride pipes (CPVC) up to 50mm dia SDR.11, ASTM CTS,CPVC schedule 80 ASTM IPS. The fittings and specials such as tees, elbows, couplers, bends, enlargers etc., with CPVC brass threaded combination / transition specials such as male adapters brass threaded female adapters, brass FPT Tee, Brass FPT elbow etc., where connection with metal is to be made including necessary drilling holes, chasing walls and making the same good in cement martor 1:1 restore the same original condition neately as directed by the Engineer incharge. Joints to be made with CPVC solvent cement up to 50mm dia as per ASTM D2846 and above 50mm dia primer P70, and solvent confirming to ASTM F4931 / 724. |
1197 | 15 mm nominal outer dia pipes |
1198 | 20 mm nominal outer dia pipes |
1199 | 25 mm nominal outer dia pipes |
1200 | Providing and fixing forged brass lever operated ball valve of full flow with forged brass ball (Machined to mirror smooth finsh with hard chrome plated) and spindle with setting and gland of superior quality having minimum working pressure of 16 kg/cm2 etc. complete in all respect. |
1201 | 20 mm dia |
1202 | 25 mm dia |
1203 | 32 mm dia |
1204 | Providing and fixing C.I butterfly valve, wafer end type class PN 1.6 as per I.S:13095 or BS:5155, including necessary nuts, bolts, gaskets etc., complete (flanges to be paid separately) |
1205 | 65 mm dia |
1206 | Supply, installation , testing & commissioning ofinsect vermin -proof coupling to vent pipes of underground tank/overhead tank with threaded or flanged joints, including M.S. flanges, nuts, bolts, 3mm thick rubber insertions complete. |
1207 | 80mm nominal bore |
1208 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm. top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5. |
1209 | Shed Development |
1210 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil |
1211 | Providing & Laying P.C.C. in 1:4:8 (1 Cement : 4 Coarse sand : 8 Approved stone ballast 40 mm nominal size)in foudation & plinth. |
1212 | P/L R.C.C. 1:1.5:3 in Slab with 20mm stone aggreigate |
1213 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
1214 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
1215 | Supply & fixing of colour coated roofing profile sheet of Tata BlueScope / Jindal or approved equivalent, nominal 980 to 1020 mm effective cover width and nominal 28 to 30 mm deep ribs with subtle square fluting in the 5 pans at nominal 190 to 210 mm centre-to-centre. The end rib shall have anti-capillary groove and return leg. The feed material to be manufactured from 0.55 mm Base Metal Thickness (0.60 mm TCT), min. 550 MPa yield strength coated with hot dip metallic Aluminium Zinc alloy coating (i.e. 55% Al, 43.4% Zinc, 1.6% Si - Zincalume), AZ150 (min. 150 gm/ m2 total on both sides) confirming to AS 1397 / ASTM A 792M / IS15961 with approved equivalent quality paint. The steel manufacturers test certificate for the chemical and mechanical properties of steel must be submitted to the concerned authority prior to installation. |
1216 | Providing & fixing flashings / ridges, wall cappings made from plain sheet of same specification as of corrugated sheets of required length, shape & size as per the detailed drawings/ directions of in-charge with necessary fasteners. |
1217 | upto 600mm Girth |
1218 | upto 900mm Girth |
1219 | Flooring |
1220 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
1221 | Providing & Laying P.C.C. in 1:4:8 (1 Cement : 4 Coarse sand : 8 Approved stone ballast 40 mm nominal size)in foudation & plinth. |
1222 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement |
1223 | Electrical work |
1224 | Wiringpointforlightwith1.5sq.mm.FRLSHPVC insulatedmultistrandsingle core copper conductor cable inheavyguageinPVCconduitpartlyconcealedinthe wallandpartlylaidinslabalongwiththereinforcement beforeconcreting,completewith 1.5 sq.mmFRLSH PVC insulated multistrand copper conductorearth continuity wire drawn inside,GP Box, Modular type switch&ceilingrose/angle/battenholderon3mmthick phenolicpaminatedbackalitesheetetccompleteinall respect as directed including matching colour wash. |
1225 | Wiringpointfortwowayslightwith1.5sq.mm.F.R. PVCinsulatedmultistrandsinglecorecopperconductor cableininsulatedmultistrandsinglecorecopper conductor cable in in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduitpartly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, GP Box and two number twonosmodulartypeswitch &ceilingrose/angle/ batten holder on 3 mm thick phanolic laminated backelite sheetetc.,complete inallrespect,asdirected,including matching colour wash. |
1226 | Wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single corecopperconductorcablePVCconduitwith1.5sq. mm.FRLSHPVCinsulatedmultistrandcoppercableas earthwiredrawninsidetheconduit.,GPBox,modular type switch & ceiling rose on 3 mm. thick backelite etc., complete in all respect including matchingwash. |
1227 | Wiring point for 5A plug with 1.5 sq. mm.FRLSH PVC insulatedmultistrandsingle core copper conductor cable inPVCconduitwith1.5mm.FRLSHPVCinsulated multistrand copper sq. cable as earthwire drawn inside the conduit concealed in wall and partly laid in slab alongwith the reinforcement before concreting,and modulartypeswitchandsocketetc.,completeinall respect including matching colour wash. |
1228 | SupplyandfixingofdoorchimeonpolishedMDFEG /Teak ply board including making connections etc. complete in all respect. |
1229 | Wiringpointforexhaustfanwith1.5sq.mm.FRLSH PVCinsulatedmultistrandsinglecorecopperconductor cableinPVCconduitwith1.5sq.mm.FRLSHPVC insulated multistrand copper conductor cable as earthwire drawninsidetheconduitpartlyconcealedinwalland partlylaidinslabalongwiththereinforcementbefore concreting,completewithGPBox,15Aswitchtype switch & ceiling rose on 3 mm thick phenolic laminated backelitesheetetc.,completeinallrespectincluding matching colour wash. |
1230 | Supply and fixing hexagonal/Round G.P.fan box of approvedmakemadeupof1.0mmthickISIMarked G.P.sheet spot welded Four to Eight holes of 25.4 mm for pipeentryofthebox.Holesshouldbesemi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwedfittedwith300mmroundzinkcotedM.S Bar X 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work. |
1231 | Wiring point for call bell with 1.5 sq. mm. FRLSH PVC insulated multistrand single core copper conductor cablen PVCconduitwith1.5sq.mm.FRLSHPVCinsulated multistrandcopperconductorcableasearthwiredrawn inside the conduit. partly concealed in wall and partly laid inslabalongwiththereinforcementbeforeconcreting completeGPBoxandmodulartypebellpushor2pin socket etc, |
1232 | Supply and fixing of power plug with 15A/250 volt flush typeswitchand5pin15A/250Vflushtypeuniversal socket in suitable M.S. box of 175mm x 100mm x 50mm sizewithphenoliclaminatedbakelitesheetcover3mm thick fixed with brass machine screw and cup washer. |
1233 | Supply and fixing of power plug with 20Amp./250 volt flush type modular switch and 5 pin 20 A/250 volt flush typeuniversalmodularsocketswitchonconcealedM.S boxincludingsupplyofallmaterial,labourT&Petc. required for proper completion of work. |
1234 | S/f of Call Bell |
1235 | S/o Invertor wiring Point for Light/Fan/Plug with 1.5mm Copper wire |
1236 | S/f of Electronics Fan Regulator moduler type |
1237 | Wiring point for fan /fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulatedmultistrandsingle core copperconductor cableinheavyguagerigidsteel conduitpipeonsurfacecompletewith14 SWG copper earth continuity wire, modular type switch & ceiling rose on 3 mm. thick phenolic laminated backelite sheet etc, complete in all respect. |
1238 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
1239 | 1 or 2 Module |
1240 | 3 Module |
1241 | 4 Module |
1242 | 6 Module |
1243 | 8 Module |
1244 | Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. |
1245 | 5/6 amps switch |
1246 | 3 pin 5/6 amp socket outlet |
1247 | Telephone socket outlet |
1248 | TV antenna socket outlet |
1249 | Supply andfixingandconcealingofPVC conduit pipe with ISI mark embossed and with PVCaccessoriesconfirming to IS No. 3419for drawing wires accessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin / adhesive to makethecompletepipingrigid,plasteringwithcement sandmortarfinishedtothelevelwithmatchingcolour washincludingcostofallmateriallabourandT&Petc required for proper completion of the work as per directions and to the satisfaction of Engineer in charge. |
1250 | 20mmdia.2mm thick PVC conduit |
1251 | 25 mm dia 2 mm thick PVC conduit. |
1252 | 32 mm dia 2 mm thick PVC conduit. |
1253 | 40 mm dia 2 mm thick PVC conduit. |
1254 | Supply and fixing of 2/3/4 ways round PVC junction box confirming to ISS PVC conduit concealed in wall, keeping its level upto plaster duly provided with propersizecover,screwedasdirectedatsitebythe EngineerI/Cwithsupply ofallthematerial,labourand T&P required for proper completion of work. |
1255 | 20mmdia.2mm thick PVC conduit |
1256 | 25 mm dia 2 mm thick PVC conduit. |
1257 | 32 mm dia 2 mm thick PVC conduit. |
1258 | 40 mm dia 2 mm thick PVC conduit. |
1259 | Supply and wiring of submains with 2 nos. 2.5 sq.mm @ with 1 no. earth wire of 1.5 sq.mm FRLSH PVC insulated 1100 V grade single core multisranded copper conductor cable in existing PVC conduit complete , including supply of all material , labour and T & P etc. required for proper completion of the work as directed by Engineer in charge. |
1260 | Supply and wiring of submain with two number 4 sq.mm. FRLSHPVCinsulated1100Vgrademultistrandsingle core copper conductor cable in 20 mm dia heavy duty (2 mm thick) PVC conduit with one no. 2.5 sq. mm. FRLSH PVCinsulatedmultistrandcopperconductorcableas earth continuity wire drawn in conduit partly concealed in walland partlylaid in slab alongwith reinforcement beforeconcreting,including matchingcolourwashetc. complete in all respect. |
1261 | Supplyandwiringofsubmainwithtwonumber6sq. mm.FRLSHPVCinsulated1100Vgrademultistrand singlecorecopperconductorcablein25mmdiaheavy duty (2mmthick)PVCconduitwithonenumber4sq. mm. FRLSH PVC insulated multistrand copper conductor cableasearthcontinuitywiredrawninconduitpartly concealed in wall and partly laid in slab alongwith reinforcementbefore concreting including matching colour wash etc. complete in all respect. |
1262 | Supply and wiring of 4 number 16 sq. mm. PVC insulated 1100Vgradesinglecore Copperconductorcablein40 mm dia PVC conduit partly concealed in wall and partly laidinslabalongwithreinforcementbeforeconcreting, with two number 10 sq mm single core Copper conductor cableasearthcontinuitywiredrawnincouditincluding matching colour wash etc, complete in all respect. |
1263 | S/w of Submain FRLSH Insulated multistand copper cond cable in HG PVC Conduit pipe concealed in wall as follws 4 sqmm 4 wire |
1264 | Supplyandwiringof4number6sq.mm.FRLSHPVC insulated1100Vgrademultistrandsinglecorecopper conductorcable in32mm diaheavy duty (2mm thick) PVC conduit with 2 nos 4 sq.mm.FRLSH PVC insulated multistrandcopperconductorcableasearthcontinuity wire drawn in conduit.partly concealed in wall and partly laidinslabalongwithreinforcementbeforeconcreting including matching colour wash etc, completeinall respect. |
1265 | Supply and wiring of 4 number 10 sq. mm. FRLSHPVC insulated1100Vgrademultistrandsinglecorecopper conductor cable in heavy duty (2 mm thick) PVC conduit with2 nos6sq.mm.FRLSHPVCinsulatedcopper conductor cable as earth continuity wire drawn in conduit.partlyconcealedinwallandpartly laidinslab alongwith reinforcement before concreting including matching colour wash etc, complete in all respect. |
1266 | S&F surface/flush mounting 8ways SPN distribution boardwith additional metal doorwithoutMCB complete in all respect, as directedbyEngineer in charge. |
1267 | S&Fsurface/Flushmounting6waysTPNdistributionboard without additional board without MCB complete in all respect, as directed at site byEngineer in charge. |
1268 | S&F of 6 Amp. to 32Amp. 4 pole MCB (10 KA) C Curve CAT-A |
1269 | S&F of 40 Amp. 4 pole MCB (10 KA) CAT-A |
1270 | S/f of 63A/4 Pole MCB CAT-A |
1271 | S&F of6 Amp. to 32Amp. DP MCB (10 KA) C Curve CAT-A |
1272 | S&F of 40Amp. DP MCB (10 KA) C Curve CAT-A |
1273 | S&F of 63Amp. DP MCB (10 KA) CAT-A |
1274 | S/f of 6 to 32 A MCB C-Type |
1275 | S&Fandmakingconnectionof25A2pole30mAELCB/ RCCBofDinRailMountingcompleteinallrespectasper direction and satisfaction to the Engineer in charge. |
1276 | S&Fandmakingconnectionof40A2pole30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge. |
1277 | S&Fandmakingconnectionof63A2pole30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge. |
1278 | S & F sheet steel enclosure for S.P/ D.P. MCB with neutral link and earth terminal. |
1279 | S & F sheet steel enclosure for T.P./Four PoleMCB. |
1280 | S&F single pole MCB blanking plate |
1281 | Supplyandfixingofbrassnickleplatedcompression glandforPVCinsulated&armouredservedsheathed, undergroundcable including rubber ring etc.complete in all respect. The armouring of the cable shall be properly connectedwiththeearthasperdirectionofEngineer- Incharge. |
1282 | 16 sq. mm 2 core |
1283 | 4 sq. mm 3 core |
1284 | 6 sq. mm 3 core |
1285 | 4 sq. mm 4 core |
1286 | 6 sq. mm 4 core |
1287 | 10 sq. mm 4 core |
1288 | 16 sq. mm 4 core |
1289 | 25 sq. mm 3-1/2 core |
1290 | 35 sq. mm 3-1/2 core |
1291 | 50 sq. mm 3-1/2 core |
1292 | 70 sq. mm 3-1/2 core |
1293 | 95 sq. mm 3-1/2 core |
1294 | 120 sq. mm 3-1/2 core |
1295 | 150 sq. mm 3-1/2 core |
1296 | 185 sq. mm 3-1/2 core |
1297 | 240 sq. mm 3-1/2 core |
1298 | 300 sq. mm 3-1/2 core |
1299 | Supplying following 1.1kV grade, heavy duty XLPE insulated, FRLS type armoured /Unarmured cables suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation, galvanised steel armouring (round or flat as mentioned) and with all components as mentioned in BOQ, specifications and schedule, complete as required. |
1300 | 3.5C x 185 sqmm aluminium conductor, A2XWY. |
1301 | 3.5C x 120 sqmm aluminium conductor, A2XWY. |
1302 | 3.5C x 95 sqmm aluminium conductor, A2XWY. |
1303 | 3.5C x 70 sqmm aluminium conductor, A2XWY. |
1304 | 3.5C x 50 sqmm aluminium conductor, A2XWY. |
1305 | 3.5C x 35 sqmm aluminium conductor, A2XWY. |
1306 | 4C X 25 sqmm copper conductor, 2XWY |
1307 | 4C X 16 sqmm copper conductor, 2XWY |
1308 | 4C X 16 sqmm copper conductor, 2XY |
1309 | 4C X 10 sqmm copper conductor, 2XWY |
1310 | 4C X 6 sqmm copper conductor, 2XY |
1311 | 4C X 4 sqmm copper conductor, 2XY |
1312 | 3C X 10 sqmm copper conductor, 2XWY |
1313 | 3C X 6 sqmm copper conductor, 2XWY |
1314 | 3C X 4 sqmm copper conductor, 2XY |
1315 | 1C X 16 sqmm copper conductor, 2XY |
1316 | 1C X 10 sqmm copper conductor, 2XY |
1317 | 2C X 6 sqmm copper conductor, 2XY |
1318 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. |
1319 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
1320 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
1321 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
1322 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
1323 | Supply and burying of 600mm x 600mm x 3mm copper plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and two earthing lead of two no. 8 SWG copper wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and copper wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. complete in all respect. |
1324 | Supplyand fixingofhorizontalair termination(roof conductor)of25mmx3mmG.I.strip,G.I.clampson surface complete in all respects as approved by Engineer- in-charge. |
1325 | Supplyandfixingofverticalairterminationfinalrod comprising of 300mm long x 25mm dia. Copper rod with onepointedprongand100mmdiax3mmthickbase plate etc. complete in all respect. |
1326 | Supply and fixing of vertical down conductor of 32mm x 6mmG.I.stripetc.onapprovedclampsonsurfacefor lightningconductorcompleteinallrespects(fortwo storeyed Buildings). |
1327 | Supply and laying of 32 mm x 6 mm G.I. strip from earth electrodedirectlyinthegroundasrequiredcompletein all respect. |
1328 | Supply and laying of 32mm x 6mm copper strip from earth electrode directly in the ground as required complete in all respect. |
1329 | Supplyandfixingoftwonumber8SWGG.I.wirein 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. |
1330 | Supplyandfixingoftwonumber8SWG copperwirein 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T&P other material required for proper completion of the work as directed at site. |
1331 | Supplying and laying of following sizeDWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming toIS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
1332 | 120 mm dia (OD-120 mm & ID-103 mm nominal) |
1333 | 200 mm dia (OD-200 mm & ID-175 mm nominal) |
1334 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. |
1335 | 100 mm dia |
1336 | 300 mm dia |
1337 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
1338 | Providing & making of inspection man hole chambers offollowing size as detailed below with 230 mm thick brick work plaster inside and outside both, PCC flooring including excavation, providing and fixing of heavy duty ISI mark SFRC cover with frame complete with RCC slab and complete as required per specifications or upto the satisfaction of engineer-in-charge. |
1339 | 1000mm X 1000 mm(depth 1.200 mtr) - 230mm Thick |
1340 | 800mm X 800 mm (depth 0.800 mtr) - 230mm Thick |
1341 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
1342 | Providing & fixing in position 1000 mm wide, Electrical Insulating Mats, 2mm thick, suitable upto 1.1 KV grade including cutting to required length complete as required per specifications or upto the satisfaction of engineer-in-charge. |
1343 | Supply & fixing in position approved shock treatment chart written in English Hindi and Local language.These charts shall be framed in wooden frame & covered with clear glass. |
1344 | Supply of Tool & First Aid Box with all necessary tools for maintenance of electrical installation & First aid. |
1345 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
1346 | 100 mm width x 50 mm depth x 1.6 mm thickness |
1347 | 150 mm width x 50 mm depth x 1.6 mm thickness |
1348 | 300 mm width x 50 mm depth x 1.6 mm thickness |
1349 | 450 mm width x 50 mm depth x 2 mm thickness |
1350 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
1351 | 100 mm width X 50 mm depth X 1.6 mm thickness |
1352 | 150 mm width X 50 mm depth X 1.6 mm thickness |
1353 | 300 mm width X 50 mm depth X 1.6 mm thickness |
1354 | 450 mm width x 50 mm depth x 2 mm thickness |
1355 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Tee” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
1356 | 100 mm width X 50 mm depth X 1.6 mm thickness |
1357 | 150 mm width X 50 mm depth X 1.6 mm thickness |
1358 | 300 mm width X 50 mm depth X 1.6 mm thickness |
1359 | 450 mm width x 50 mm depth x 2 mm thickness |
1360 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Cross member” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
1361 | 100 mm width X 50 mm depth X 1.6 mm thickness |
1362 | 150 mm width X 50 mm depth X 1.6 mm thickness |
1363 | 300 mm width X 50 mm depth X 1.6 mm thickness |
1364 | 450 mm width x 50 mm depth x 2 mm thickness |
1365 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “Reducer” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
1366 | 100 mm width X 50 mm depth X 1.6 mm thickness |
1367 | 150 mm width X 50 mm depth X 1.6 mm thickness |
1368 | 300 mm width X 50 mm depth X 1.6 mm thickness |
1369 | 450 mm width x 50 mm depth x 2 mm thickness |
1370 | Supply andfixing of recess/Surface/Pendent mountinground6Watt8WattLEDDownLighter havingPowdercoateddiecastaluminiumhousing withheatsink,diffuser/Reflectoranddriverset complete in all respect. CAT-AAA |
1371 | Supply and fixing ofrecess/ Surface/ Pendent mountinground 10to15WattLEDDownLighter havingPowdercoateddiecastaluminiumhousing with heatsink,diffuser/Reflectoranddriverset complete in all respect. CAT- AAA |
1372 | Supply and fixing ofrecessmounting round 15 to 18 WattLED DownLighterhavingPowdercoated die castaluminiumhousingwith heatsink,diffuser/ Reflector and driver set complete in all respect. CAT- AAA |
1373 | Supplyandfixingof36Wattto46Wattindoor Recess mounting LED Square Fitting for Armstrong CeilinghavingPowdercoateddiecastaluminium housing body withextended heat sink and diffuser of SpecialPolycarbonatemeterialanddriverset complete in all respect. CAT-AAA |
1374 | SupplyandfixingofLEDTubeLightwithbatten suitable forupto1X 22watt LED tube lightfitting includingtubeonSurfacecompleteinallrespect. CAT-AAA |
1375 | Supply and fixing ofwater tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection . complete in allrespect. CAT-AAA |
1376 | Supply & Fixing of40WattLED Surface Mounting weatherproof Luminaire with PCHousing andopal finishcoverconfirmingtoIP65Completeinall respect. CAT-AAA |
1377 | Erection andtestingofexhaustfanontheexistinghole withsuitablesizeofragbolts,nutsandwashersetc., complete in all respect. |
1378 | Erectionandtestingofceilingfanandregulatoretc. excluding supply of down rod, complete in all respect. |
1379 | Cost of 1200mm Ceilling Fan sweep |
1380 | Cost of 300mm Ex-Fan Fan |
1381 | Supply and fixing of batten / angleholder complete in all respect. |
1382 | Development of Site |
1383 | Excavation in foundation in Ordinary soil (loamclay or sand) including lift upto 1.5m. And lead up to 30m. And including filling, watering and ramming of excavated earth into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the E.I.C. up to a distance of 30m. from the foundation trenches including all T&P phowarah and basket etc. complete. |
1384 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
1385 | Internal Road |
1386 | Construction of granular sub-base With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. |
1387 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. |
1388 | Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. |
1389 | (Note :- Cement content considered in this item is @ 330 kg/ cum.Excess/less cement used as per design mix is payable/recoverable separately). |
1390 | All works upto plinth level |
1391 | All works above plinth level upto floor V level |
1392 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete for proper completion of the work and including supply of steel its wastage.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
1393 | M-15 Sub Class (A) Brick work in 1:6 cement and sand of 1.25 fineness modulus mortar in foundation and plinth including supply of all materials, labour, T&P etc. required for proper completion of work. |
1394 | As in item 302 to 307 above but in superstructure including necessary cutting and moulding of bricks and also including honey comb brick work, thickness of walls more than one brick and for extra labour to above items. |
1395 | As in item no. 309 above but for one brick wall add for extra labour. |
1396 | 15 mm cement plaster on rough side of single or half brick wall of mix : (with coarse sand): |
1397 | 1:6 (1 cement: 6 coarse sand) |
1398 | Finishing walls with textured exterior paint of required shade New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm including base perparation with cement based putty & applying additional coats wherever required to achieve even shade and colour. |
1399 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required in stringers, treads, landings etc. of stair cases, Railing including use of chequered plate wherever required, all complete. |
1400 | SURFACE FINISHING |
1401 | Interlocking Paver Providing and laying of interlocking concrete Block pavement having thickness 80mm as per drawings and technical specification clause 1504. (Exclusive G.S.B.) |
1402 | Providing and laying quartzite cobble 100mm thick as per approved pattern layed in cement mortar 1:4 with gap of 10-12mm. Gap will grout with pigmented cement paste of ( 1 cement : 1 Fine sand ). all work complete as per approved pattern and color as per direction of Engineer-In-Charge and Architect.( Base Rate Rs. 300 / Sft F.O.R. at site without GST ) |
1403 | Providing and laying 225 x 112.5 x 37.5 mm clay paver laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.all work complete as per approved pattern and color as per direction of Engineer-In-Charge and Architect.( Basic rate Rs. 220/- per Sft F.O.R. site With out GST ) |
1404 | Grass Paver Supplying & laying Grass Track Grass Pavers of approved make Green honeycomb panels with self anchoring pegs, made of high impact resistant HDPE. Each grass paver should be of 330mm x 330mm & 35mm in height consisting of four floral shaped structure of 125mm open cell & nine round cell opening of 45 mm dia. Each of the open cell are connected with a web like structure for strength & stability. Base of the panel is equipped with a slot opening for drainage & four round struts for anchoring purpose. The Grass Paver to have interlock system to lock each other. The Grass Paver should have compressive strength of minimum 150 tons/sq mt, capable to take the load of the fire tender. The panel should have high level of porosity greater than 90%, porous for Grass, shrubs & low planters. Laying to be done as per manufacturer specifications & directions of Engineer-in-Charge. |
1405 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). |
1406 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
1407 | EXTERNAL DRAINAGE & WATER SUPPLY |
1408 | Sewer & Drainage |
1409 | Open sewer & Strom water drainage lines grid ( on either side of the roads or between road edge & plateformleading to RWH recharge pit. |
1410 | Under ground Sewer line at depth 0 to 1.5 mtr with 600mm dia RCC NP-3 hume pipe. |
1411 | Under ground Sewer line at depth 1.5 to 3.0 mtr with 600mm dia RCC NP-3 hume pipe. |
1412 | Water Supply |
1413 | External water supply grid from submersible bore well outlet to building |
1414 | Boring of tube well and pump house |
1415 | STREET LIGHTING & SIGNAGES |
1416 | Supply and fixing of reflective sign board (single side) retro reflectice sheeting of HIP grade type-IV, the board shall be fixed on 50mm SS 304 grade pipe and reflective sheet on 4 mm thick, ACP sheet of standard make as per MORTH specification. The board shall be fixed using 2man post 45x45x60cm cement concrete foundation. The stainless steel joint welding of SS pipe work shall be band and grinder properly including buffng so an to give uniform shining at welded joints,. the retro reflective sheeting shall be tested for 3 year outdoor weathering test in Indian conditions as per IRC 67:2012 & proof of the same in form of government report shall be uploaded while quoting tender. Size as per the site requirement. All complete as per the approval of the Architect/ Engineer-in-charge. |
1417 | Supply and fixing of reflective sign board (double side) retro reflectice sheeting of HIP grade type-IV, the board shall be fixed on 50mm SS 304 grade pipe and reflective sheet on 4 mm thick, ACP sheet of standard make as per MORTH specification. The board shall be fixed using 2man post 45x45x60cm cement concrete foundation. The stainless steel joint welding of SS pipe work shall be band and grinder properly including buffng so an to give uniform shining at welded joints,. the retro reflective sheeting shall be tested for 3 year outdoor weathering test in Indian conditions as per IRC 67:2012 & proof of the same in form of government report shall be uploaded while quoting tender. Size as per the site requirement and direction of E-I-C. |
1418 | Supplying,installation,testing and commissioning of 6.0meterHeighthotdipgalvanisedcontinously tapered (bolt fixing type) octagonalPole including 60 watt LED Fixture, colour cool white , integral driver, protection IP 65, CLASS Iwithtop 70 mm dia and bottom 130 mm dia made of 3 mm thick H T sheet Steelconforming to grade S 355 complete with G Ibase plate of size 220 mm(L) X 220 mm(B) X 12 mmthicknesswelded at bottom of pole completewith4 Nos 20 mm dia 750 mm longfoundationboltsconfromingtoEN8grade,inbuilt/Vandalresistance,weathproofelectrical junction box having terminalblock,MCB etc. mounted on bakelite sheet forlooping in /looping out of cables,withflushdoorhavinglockingarrangement, earthing arrangement(atatleast 0.5mheight) and mounted on RCC foundation of size 450 mm x 450 mm x 800 mm in ground and 200 mm above ground level with foundation bolt duly embeded before casting and supply and embedding ofsuitable size HDPE pipe sleeve for cable entry. complete including erection of Pole complete in all respectas required. |
1419 | HORTICULTURE & LANDSCAPING |
1420 | Trenching in ordinary soil up to a depth of 60 cm including removal & stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). |
1421 | Supplying and stacking of good earth at site including royalty and carriage up to 5 km (earth measured in stacks will be reduced by 20% for payment). |
1422 | Supplying and stacking sludge or manure at site including royalty and carriage up to 5 km (sludge measured in stacks will be reduced by 8% for payment). |
1423 | Supplying and stacking at site dump manure from approved source, including carriage up to 5 km (manure measured in stacks will be reduced by 8% for payment): |
1424 | Screened through sieve of I.S. designation 4.75 mm |
1425 | Rough dressing the trenched ground including breaking clods. |
1426 | Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. |
1427 | Fine dressing of the ground |
1428 | Spreading of sludge, dump manure, coco peat, lime, oil cake and/ or good earth in required thickness as per direction of Architect/ Engineer-In-Charge (Cost of sludge, dump manure, coco peat, lime, oil cake and/ or good earth to be paid separately). |
1429 | Mixing earth, sludge, coco peat or manure in the required proportion specified or directed by the Architect/ Engineer-in-Charge |
1430 | Grassing with Selection No. 1 grass including watering and maintenance of the lawn for 60 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and earth shall be paid for separately). |
1431 | In rows 5 cm apart in both directions (dibbling in triangular pattern) |
1432 | Supplying & Stacking Selection no. 1 grass turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with required tools wooden and than rolling the surface with light roller make the surface smoothen and light watering the same, as per direction of Architect/ Engineer-In-Charge |
1433 | Supplying & Stacking Doob grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light watering with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of Architect/ Engineer-In-Charge |
1434 | Supplying & Stacking of Selection No.1 Grass at site fresh & free from weeds having proper roots in green including loading, unloading, carriage and all taxes paid etc. and as per direction of Architect/ Engineer-In-Charge |
1435 | Supplying& Stacking of Doob grass at site fresh & free from weeds having proper roots in green including loading, unloading, carriage and all taxes paid etc. and as per direction of Architect/Landscape Consultant. |
1436 | Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts. |
1437 | Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately). |
1438 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : |
1439 | Holes 1.2 m dia and 75 cm deep |
1440 | Holes 0.9 m dia and 75 cm deep |
1441 | Holes 0.6 m dia and 45 cm deep |
1442 | Holes 0.45 m dia and 45 cm deep |
1443 | Ploughing the existing ground to a depth of 15 cm to 25 cm and watering the same |
1444 | In all kinds of soil |
1445 | Supplying planting specified shrubs as per the landscape plan |
1446 | Supply and stacking of plant Caesalpinia pulcherrima of height 75 cm in poly bags of size 25 cm as per direction of the Architect/ Landscape Consultant. |
1447 | Supply and stacking of plant Duranta repens of height 60 cm in poly bags of size 20 cm as per direction of the Architect/ Landscape Consultant |
1448 | Supply and stacking of plant Glandularia pulchella of height 30 cm in poly bags of size 10 cm as per direction of the Architect/ Landscape Consultant |
1449 | Supply and stacking of plant Lantana sellowiana ‘monma’ of height 30 cm in poly bags of size 20 cm as per direction of the Architect/ Landscape Consultant. |
1450 | Supply and stacking of plant Lantana sellowiana of height 30 cm in poly bags of size 20 cm as per direction of the Architect/ Landscape Consultant. |
1451 | Supply and stacking of plant Plumbago capensis of height 75 cm in poly bags of size 20 cm as per direction of the Architect/ Landscape Consultant. |
1452 | Supply and stacking of plant Rhoeo spathacea of height 30cm in poly bags of size 20 cm as per direction of the Architect/ Landscape Consultant. |
1453 | Supply and stacking of plant Tabernaemontana coronaria of height 90cm in poly bags of size 30 cm as per direction of the Architect/ Landscape Consultant. |
1454 | Supply and stacking of plant Tabernaemontana coronaria (compact) of height 45cm in poly bags of size 20 cm as per direction of the Architect/ Landscape Consultant. |
1455 | Supply and stacking of plant Hamelia patens of height 60 cm in poly bags of size 30 cm as per direction of the Architect/ Landscape Consultant. |
1456 | Supply and stacking of plant Galphimia gracilis of height 90 cm in poly bags of size 45cm as per direction of the Architect/ Landscape Consultant. |
1457 | Supply and stacking of plant Ocimum basilicum of height 45 cm in poly bags of size 25 cm as per direction of the Architect/ Landscape Consultant. |
1458 | Supply and stacking of plant Tradescantia zebrina of height 30 cm in poly bags of size 25 cm as per direction of the Architect/ Landscape Consultant. |
1459 | Supply and stacking of plant Pennisetum setaceum of height 120 cm in poly bags of size 60 cm as per direction of the Architect/ Landscape Consultant. |
1460 | Supply and stacking of plant Seasonal and Self-seeding Flower Mix as per direction of the Architect/ Landscape Consultant. |
1461 | Supplying planting the following specified trees as per the landscape plan |
1462 | Supply and stacking of Bombax ceiba plant of height 300 cm, in 45 cm size ofEarthen Pot / Plastic Pot & as per direction of the Architect/ Landscape Consultant. |
1463 | Supply and stacking of Erythrina variegata plant of height 240 cm, in 45 cm size ofEarthen Pot / Plastic Pot & as per direction of the Architect/ Landscape Consultant. |
1464 | Supply and stacking of Jacaranda mimosifolia plant of height 240 cm, in 45 cm size ofEarthen Pot / Plastic Pot & as per direction of the Architect/ Landscape Consultant. |
1465 | Supply and stacking ofBauhinia variegata plant of height 150 cm, in 45 cm size ofEarthen Pot / Plastic Pot & as per direction of the Architect/ Landscape Consultant. |
1466 | Supplying planting the following specified palm plants as per the landscape plan |
1467 | Supply and stacking ofRhapis exelsa plant of height 90 cm, full of branches and foliage in 45 cm size ofEarthen Pot / Plastic Pot & as per direction of the Architect/ Landscape Consultant. |
1468 | Supplying planting the following specified climber plants as per the landscape plan |
1469 | Supply and stacking ofBougainvillea glabra plant of height 90 cm, full of branches and foliage in 45 cm size ofEarthen Pot / Plastic Pot & as per direction of the Architect/ Landscape Consultant. |
1470 | Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserviceable materials as per direction of Architect/ Engineer-In-Charge (excluding cost of plant and water) |
1471 | Trees planting and staking |
1472 | Shrubs plant |
1473 | Climber |
1474 | Hand broadcasting of seed mix as specified, mixed with sand and scattered by hand or seed spreader. To help embed the seeds, hand rake the ground to roughen it up (scarify), including lightly compressing the seeds into the soil (do not bury them) by either walking on them, or by running a roller over the area.And watering so that the soil is moist, not soaking wet, until the seedlings are 4-6" tall. After that, the seedlings should survive on natural rains. Occasional watering may be needed in extremely dry weather. No soil amendment (fertilizer or manure). |
1475 | Complete maintenance of the entire garden features having as per yard stick in the garden area i.e. lawn trees, shrubs, hedge, flower beds, foliages, creepers etc. including hoeing,weeding pruning replacement of plants, gap filling, watering, mowing of lawn, grass cutting by lawn mover and brush cutter , removal of garden waste, applying insecticide, pesticide & fertilizers(whenever required) top dressing of lawn with good earth and manure and maintenance of other garden related works as directed by Office-in-charge, for a period of 3 months till healthy plants are established at site. |
1476 | Carriage of Good Earth by mechanical transport (rates will be applicable to net quantities after deduction of prescribed percentage of voids mentioned in the specification under subhead “Carriage of Materials) |
1477 | Upto 1 KM |
1478 | More than 1Km up to 2KM |
1479 | More than 2Km up to 3KM |
1480 | Supplying and stacking at site coco peat blocks (30x30x12 cm +/-2mm, each block weighing 5kg +/- 200g with a compression ratio of 1:5) from approved source, including carriage up to 5 km. |
1481 | Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and levelling (cost of supplying earth and sludge or manure and mixing excluded). |
1482 | Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5 k.m. lead complete (cattle manure measured in stacks will reduced by 8% for Payment). |
1483 | Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Architect/ Engineer-In-Charge |
1484 | Supplying and stacking at site unslaked lime, including carriage up to 5 km. (DSR 2016 items 0773 + 2208) |
1485 | Supplying and stacking at site oil cake (neem/castor/etc.), including carriage up to 5 km. |
1486 | GST extra as per applicable |