Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | NEW A SITE RO-SHRIPUR : CIVIL |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600 |
| 3 | i) All kinds of Soil |
| 4 | Extra for every additional lift of 1.5m or part thereof in excavation or banking excavated or stacked materials in all kinds of soil |
| 5 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m |
| 6 | i) Local Fine Sand within grading zone IV |
| 7 | Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: |
| 8 | iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) |
| 9 | v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm) |
| 10 | viii) 1:4:8(1 Cement :4 Coarse Sand :8 Graded stone aggregate of 40mm) |
| 11 | Centeringand shutteringincludingstrutting,proppingetc. and removal of form work for: |
| 12 | i) Foundations,footings,bases of column |
| 13 | Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level |
| 14 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
| 15 | Providing & Laying Reinforcedcementconcreteworkinwalls (Any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level UP TO FLOOR V LEVEL excluding cost of centering, shuttering, finishing and reinforcement : |
| 16 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
| 17 | Reinforced cement concrete work in beams, suspended floors, roofshavingslopeupto15°landings,balconies,shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate 20 mm nominal size) |
| 18 | Providing and laying RCC work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 20 | i) Foundations,footings,bases of columns, etc. for mass concrete |
| 21 | v) Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 22 | vii) Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards |
| 23 | viii) Suspended floors, roofs,landings balconies and access platform with water proof ply 12mm thick |
| 24 | ix) Lintels, beams, plinth beams, girders, bressumers cantilevers and with water proof ply 12mm thick |
| 25 | Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels |
| 26 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 |
| 27 | Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth |
| 28 | ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH |
| 29 | iv) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand)in superstructure in all shapes & sizes in superstructure ABOVE PLINTH & UP TO FLOOR V LEVEL |
| 30 | Brick on edge flooring with bricks of Class designation 7.5 on a bed of 12mm cement mortar including filing the joints with same mortar with common burnt clay non modular bricks |
| 31 | ii) cement mortar 1:6 (1 cement : 6 fine sand) |
| 32 | x) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement:4 coarse sand in superstructureABOVE PLINTH level & UP TO FLOOR V LEVEL |
| 33 | Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks |
| 34 | Providingandfixing18mmthickgangsawcutmirrorpolished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. |
| 35 | iv) Granite of any colour and shade having Area of slab over 0.50 sqm |
| 36 | Providing & fixing MS grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc.including priming coat with approved steel primer (fixed to steel windows by welding) all complete. |
| 37 | Providing & fixing chrome plated brass100mm mortise latch with one dead bolt with 6 levers & a pair of lever handles with necessary screws etc. complete (best make of approved quality). |
| 38 | Providing and fixing 150 mm bright finished chrome plated brass hanging type floor door stopper with rubber cushion necessary brass screws, etc. complete. to suit shutter thickness complete |
| 39 | Providing & fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 40 | i) 250x10 mm |
| 41 | ii) 200x10 mm |
| 42 | Providing & fixingaluminium handles ISImarked anodised(anodic coating not less than grade AC10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 43 | i) 125 mm |
| 44 | Structural steel work riveted, bolted or welded in single section fixed with or without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 45 | Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: |
| 46 | Supplying and fixing rolling shutters of approved make, madeof required size M.S. laths interlocked together through their entire length,jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS 4454 Part-I & M.S. top cover of required thickness for rolling shutters:- 80x1.25mm MS laths with1.25 mm thick top cover |
| 47 | Extra for providing grilled rolling shutters manufactured out of 8 mm dia. M.S. bar instead of laths as per design approved by Engineer-in- charge.(area of grill to be measured). |
| 48 | i) Hot finished welded type tubes |
| 49 | Providing and laying matt finished vitrified tile of following size having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals locationetc., laid on 20mm thick base of cement mortar 1:4 (1 cement: 4 coarse sand) in all shapes and patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. |
| 50 | i) Flooring with size of Tiles 40x40Cm in cement mortar 1:4 |
| 51 | Providing & fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (minimum thickness of 5 mm) of approved make in all colours,shades except burgundy,bottle green,black of any size as approved by Engineer-in-Charge in skirting,risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointinginwhite cementmixed withpigment ofmatchingshade. |
| 52 | Providing & laying Ceramic Glazed floor tiles 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours White, Ivory, Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) jointing with grey cement slurry@ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc. complete. |
| 53 | Providing & laying vitrified floor tile in different sizes (thickness as per manufacturer) with water absorption\"s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar as specified with coarse sand jointing with greycement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete for flooring/skirting as specified |
| 54 | i)Flooring with size of Tiles 60x60Cm in cement mortar 1:4 |
| 55 | iii) Skirting with size of Tiles 60x60Cm in Cement mortar 1:3 |
| 56 | Providing and fixing Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of Cold rolled steel confirming to IS:513-2008 of base metal thickness 0.50 mm, having Yield Stress of Min. 275 MPa. Steel surface shall have hot dip metallic coating of Al-Zinc alloy comprising 55% Alluminium, 43.5% Zinc and 1.5% Silicon as per the ASTM-A792M, with total mass of coating on both sides shall be 150 gms/sqm. The steel shall have organic coating with Silicon Modified Polyester (SMP) /Super Durable Polyester (SDP) paint on continuous coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns SMP /SDP paint over 5-7 microns epoxy primer) and back side 8-10 Microns SMP/SDP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.58 MM. Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m or as desired by Engineer-in-charge. |
| 57 | Providing & fixing BARE Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) ofbare metal thickness 0.55 mm as per ASTM A446 having yield stress of 275mpa, surface shall have hot dip metallic coating of Aluminium Zinc alloy comprising of 55% aluminium,43.5% zinc & 1.5% silicon, Sheet shall have protective guard film of25 microns minimum to avoid scratches while transportation & should be supplied in single length up to 6m or as desired by Engineer-in-charge. |
| 58 | ii) Plain Sheet for Ridges (500 - 600mm). |
| 59 | iii) Plain sheet for Flashings/ Aprons (Upto 600 mm) |
| 60 | iv) Plain Sheet for Gutter (600 mm over all girth) |
| 61 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. |
| 62 | ii) 110 mm diameter |
| 63 | Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa and 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continues coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure. |
| 64 | Providing and laying cement plaster on surfaces with Coarse sand including curing etc. |
| 65 | ii) 12mm Cement plaster of mix 1:6 (1 cement: 6 coarse sand) |
| 66 | i) 6mm thick plaster of mix 1:3 (1 cement: 3 fine sand) |
| 67 | Providing Neat cement punning |
| 68 | Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 69 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 70 | Finishing walls with Acrylic Smooth exterior paint of required shade (2 or more coat applied @ 1.67 ltr/10 sqm over & including priming coat of exterior Primer applied @ 2.20kg/10 sqm) |
| 71 | Finishing walls with Deluxe Multi surface paint system for interiors & exteriors using Primer as per manufacturers specifications with two or more coats applied on wall @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm |
| 72 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade with 2 or more coats |
| 73 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 74 | Lettering with black japan paint of approved brand & manufacture and (unit/letter/cm ht) |
| 75 | Construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mixer plant at Optimum Moisture Content, carriage of mixed material by tippers to work site, for all lead and lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface & compacting with vibratory power roller to achieve the desired density, complete as per specification & direction of Engineer-in-charge. |
| 76 | i) With material confirming to grade-I (size 75 mm to .075 mm) having CBR value - 30, Thickness as desired |
| 77 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to .075 mm) to wet mix macadam (WMM) specifications including premixing the material with water at OMC for all leads and lifts, laying in uniform layers with mechanical paver finisher in sub-base/base course on well prepared surface and compacting with vibratory roller of 8 to 10 ton capacity to achieve the desired density, complete as per specifications & directions of Engineer-in- charge |
| 78 | Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. |
| 79 | Providing & fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete |
| 80 | iv) With Flexible pipe of 40 mm dia |
| 81 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 82 | Boring/drilling bore well of required dia for casing/ strainer pipe by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, |
| 83 | i) 100mm dia in all types of soil up to 90m depth below ground |
| 84 | Providing and fixing Chlorinated PolyvinylChloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall |
| 85 | i) 15 mm nominal outer dia Pipes |
| 86 | ii) 20 mm nominal outer dia Pipes |
| 87 | iii) 25 mm nominal outer dia Pipes |
| 88 | v) 40 mm nominal outer dia Pipes |
| 89 | Providing and fixing Chlorinated PolyvinylChloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc. |
| 90 | ii) 20 mm nominal outer dia Pipes |
| 91 | iii) 25 mm nominal outer dia Pipes |
| 92 | Providing and fixing B class G.I. pipes complete with G.I. fittings & clamps, i/c cutting & making good the walls etc. Internal work Exposed on wall. |
| 93 | i) 15 mm nominal outer dia Pipes |
| 94 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 95 | i) 25 mm nominal bore |
| 96 | iii) 40 mm nominal bore |
| 97 | Constructing masonry Chamber 60x60x75 cm,inside in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valves etc, with CI surface box 100mm. top diameter,160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominalsize), i/c necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement:3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S (non modular) bricks of class designation 7.5 |
| 98 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank IS : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 99 | Providing and fixing PTMT grating of approved quality and colour. |
| 100 | ii) Circular type 125 mm nominal dia with 25 mm waste hole |
| 101 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement:3 coarse sand) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment) (Precast C.C. kerb stone shall be approved by Engineer-in-charge. |
| 102 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and SW drain pipe 100 mm diameter, 1.8 m long complete as per standard design with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 103 | Boring with hydraulic piling rigs with power units, Providing & installing cast insitu single under reamed piles of specified diameter and length below pile cap in M 25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto the bottom of pile cap) |
| 104 | i) 300 mm dia piles |
| 105 | Extra over item for Single under ream pile for providing additional bulb in under reamed piles, under specified dia meter (Only the quantity of extra bulbs are to be paid) |
| 106 | i) 300 mm dia piles |
| 107 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions,at top, bottom & sides with with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws including fixingall complete as per drawing & the directions of Engineer-in-charge. (Cost of glazing or panels to be paid for separately) |
| 108 | i) Fixed Glazing with Powder coated aluminium (minimum thickness of powder coating 50 micron) sections |
| 109 | iii) For shutters of doors, windows & ventilators with Powder coated aluminium sections including providing fixing hinges/ pivots & making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 110 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): |
| 111 | i) With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 112 | ii) With float glass panes of 5.0 mm thickness (weight not less than 12.5kg/sqm) |
| 113 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately). |
| 114 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. |
| 115 | i) With stainless steel cover plate minimum 1.25 mm thickness |
| 116 | Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc. complete as per direction of Engineer-in-Charge. |
| 117 | i) Powder coated minimum thickness 50 micron aluminium tubular handle bar |
| 118 | Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Standards and as approved by Engineer-in-charge : |
| 119 | v) 25mm dia x 1000mm long with 100 mm dia x 8 mm thick plate |
| 120 | xvi) 300mm dia in all types of soil 90m to 150m depth |
| 121 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticised PVC medium well casing (CM) pipe of required dia,conforming to IS:12818, including required hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
| 122 | i) 100 mm nominal size dia |
| 123 | ii) 150 mm nominal size dia |
| 124 | Supply and packing Gravel in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 125 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: |
| 126 | i) 100 mm dia |
| 127 | Providing and fixing M.S. clamp of required dia to the top of casing / housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete |
| 128 | i) 100 mm dia clamp |
| 129 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). |
| 130 | i) 100 mm dia |
| 131 | ii) M40 grade 80 mm thick reflective type Lacquered finish |
| 132 | CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items |
| 133 | iv) 3 Core x 2.5 sq. mm Copper Cable FRLS |
| 134 | xviii) 3.5 Core x 50 sq. mm Aluminium Cable FRLS |
| 135 | SUPPLY AND LAYING OF FLAT CABLES |
| 136 | i) 3core, 2.5 sq.mm copper Flat Cable for submersible pump |
| 137 | Supplying, fabricating and installing following sizes of perforated GI cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling and/or fix to steel/RCC columns, beams or any other structure members with MS suspenders, angles, channels, etc complete as per the direction of IndianOil |
| 138 | ii) 200mm x 50mm x 2mm |
| 139 | Supply & Fixing of Weatherproof (IP-65) Thermoplastic Cable Junction Box with terminal block fitted inside the box suitable for following cable sizes. |
| 140 | i) for 2.5 sq.mm. cable entry size with 9 terminals |
| 141 | Providing, fixing, testing and commissioning of FLPjunction box of approved make for cable connection/ jointing. |
| 142 | i) For cables 2.5 to 4 sqmm XLPE / AYFY |
| 143 | Providing & fixing flexible copper cable PVC insulated of 16sqmm for connecting the earth grid/earth strip with the crocodile clip i/c cost of 1 no. crocodile clip (for tanker earthing & other job) |
| 144 | i) Electrical insulating mats made of PVC Elastomer 3mm Thick & 1 mtr wide near swichboards, etc as per direction of Engineer In charge. Mat should conform to IS 15652 Class A - suitable for safe working voltage of upto 33 kV. Test certificate to be provided with supply. Mat\"s top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip. Mat\"s top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip. |
| 145 | ii) 6 mm thick chequered plate on cable trench inside swtich room, DG room, earthing pit including cutting, painting, lifting hooks, etc |
| 146 | iii) Supply and fixing of shock treatment chart in English, Hindi & local language framed in glass framework. |
| 147 | iv) 11 KV grade hand gloves, ISI mark |
| 148 | ii) Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 149 | Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make |
| 150 | ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire |
| 151 | ii) 5 Amp modulartypeswitch |
| 152 | iii) 5 Amp Pianotype3 pinsocket |
| 153 | iv) 15Ampmodular typeswitch |
| 154 | v) 15Ampmodular type6 pin socket |
| 155 | Supplying and fixing of following MCBs with necessery inter connectionson existing DB, Panel board etc. |
| 156 | ii) Upto 32A DP MCB |
| 157 | Supply and installation of MCB distribution boardhaving Doubledoorcomplete with tinned cu bus bar, neutral bus bar, earth bar, din bar, interconnection, earthing etc. withoutincoming isolator and MCBs |
| 158 | ii) 2+8 way SPN |
| 159 | ii) 63 Amps., 4 Pole |
| 160 | CEILING FANS Supply & fixing of ceiling fan for inside of the sales building of following type: |
| 161 | iii) 1200 mm sweep |
| 162 | EXHAUST FANS Supply and fixing of exhaust fan including electrical wiring all shall be with per specification and direction of site In charge. The fans shall be with louvers / shutters. (The job does notinclude making suitable cut out in thewall for fixing the fan). |
| 163 | ii) 9\" dia light duty, make Khaitan or equivalent |
| 164 | SUBMERSIBLE PUMP Supply,erection,testing & Commissioning of foll.submersible water pump with starter panel board, non return valve, gate valve etc. complete. |
| 165 | ii) 33 LPM 100m head |
| 166 | Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watt, having IP65 protection class with Pressure Die Cast Aluminium housing & with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. The LED shall be operating under voltage range of 140-270V with power factor more than 0.9. CCT(Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), CRI (Colour rendering index) not less than 65. LED efficacy should be minimum 100 lumens/watt. The driver shall be of constant volt & constant current type with internal surge protection. Each lot of Fittings shall have serial numbers and accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc. |
| 167 | Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 8 Watt, having IP20 protection class with Pressure Die Cast Aluminium housing & with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. The LED shall be operating under voltage range of 140-270V with power factor more than 0.9. CCT(Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), CRI (Colour rendering index) not less than 65. LED efficacy should be minimum 100 lumens/watt. The driver shall be of constant volt & constant current type with internal surge protection. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports & reference/batch nos of LEDs & fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc. |
| 168 | Supplying and fixing of 10mm thick mirror polished black granite tiles for pump island edges etc. over 12mm thick CM 1:4 including cost of all materials and labour etc. complete. |
| 169 | Supply and Installation of Flame Proof ESD Push Button |
| 170 | Boring, providing and installing bored cast-in-situ reinforced cement concrete piles of grade M 25 of specified diameter and length below the pile cap to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with, bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler, mounted, Telescopic Boom Hydraulic pilling Rig all complete. including removal of excavated earth with all lifts & leads (Length of pile for payment shall be measured upto bottom of pile cap). Truck mounted rotary/TMR/Tubewell boring machine shall not be used |
| 171 | i) 300 mm dia piles |
| 172 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts collar and bush of approved quality and colour. |
| 173 | ii) 15 mm nominal bore with 45 cm length. |
| 174 | xii) Fan Regulator of stepped modular type |
| 175 | iv) 32 mm nominal outer dia Pipes |
| 176 | iii) S/W Slipon flanges of 50 mm dia. conforming to IS2062 GrA, ANSI B16.5,Class 150 as per specifications and standard Drg.enclosed herein |
| 177 | iii) Making Flange joint between Slip on,blind and flange etc.of 50 mm dia. including gasket, nuts, bolts,3mm dia copper wire bonding |
| 178 | i) Upto 32A SP MCB |
| 179 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth within premises |
| 180 | i) 75 mm diameter |
| 181 | i) C.P. brass |
| 182 | iv) 34.00 mm OD SS pipe |
| 183 | i) 15.88 mm OD SS pipe |
| 184 | i) 12mm dia x 300mm long with 75 mm dia x 3 mm thick plate |
| 185 | vi) 12 module frame |
| 186 | iv) 6 module frame |
| 187 | v) 8 module frame |
| 188 | 40mm Thick Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand:4 stone aggregate of 20mm nominal size) finished with a floating cement coat of neat including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 189 | iii) S/L Threaded A/G HD MS Pipes of 50 mm dia with fittings,Painting |
| 190 | Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen= 2100lm.Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc |
| 191 | Providingandfixingmachinemouldedaluminiumcovering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceilings, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick & 15 mm dia, at a staggered pitch of 200 mm centre to centre including drilling holes in the receiving surface and expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-charge. |
| 192 | ii) Powder coated aluminium sheet 2.5mm thick(minimum thickness of powder coating 50 micron) |
| 193 | Providing and fixing 450 mm long CP Brass towel rail complete with brackets fixed to wooden/PVC cleats with SS screws with concealed fittings arrangement of Make: Cera F5007104 or equivalent all complete and as per direction of Engineer-in-charge. |
| 194 | Providing and fixing of SS single Soap tray with all fittings and all complete, as per specification and direction of Engineer-in-charge. |
| 195 | Providing and fixing H type double tone SS Pull handle of GODREJ (7268) or equivalent make with all tools, tackles etc. all complete, as per specification and direction of Engineer-in-charge. |
| 196 | Providing and fixing Chrome Finish SS Health faucet with 8mm dia, 1 meter long SS braided rubber hose pipe and wall hook with N.R.V, Jaguar make cat. No. ALD-577 or equivalent all complete, as per specification and direction of Engineer-in-charge. |
| 197 | Providing and fixing first quality (heavy duty) type glazed vitreous china P or S trap Wall hung coloured water closet, seat cover, CP nuts, bolts and other necessary fittings all complete and as per specification and direction of Engineer-in-charge. |
| 198 | Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs, beams during laying including painting the exposed portion ofloop, all as per standard design complete. |
| 199 | ii) Rangeoftwourinalbasinswith5litrewhiteP.V.C. automatic flushing cistern |
| 200 | Writing name of Retail Outlet and location/ Indian Oil Corporation monogram, other sign / slogans on building / glass of show window etc. of the following heights / diameters with vinyl sticker of approved quality and shade. 150 micron thickNon Reflective Vinyl sticker3M or Equivalent Brand |
| 201 | ii) Letter of size 6 to 15 cms |
| 202 | iii) Letter of size from 16 to 25 cms |
| 203 | iv) Letter of size from 26 to 70 cms |
| 204 | FRP Septic Tank (1200 Litres Syntex Make |
| 205 | S/F of Counter sunk - Wash Basin of size |
| 206 | Pressmatic Type Pillar Cock |
| 207 | S/F Backlit LED lettering (per inch lett |
| 208 | NEW A SITE RO-SHRIPUR : P&M |
| 209 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling & neatly dressing of disposed soil completely to be paid separately as per item no. MPLCN00600 |
| 210 | i) All kinds of Soil |
| 211 | i) Local Fine Sand within grading zone IV |
| 212 | Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: |
| 213 | iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) |
| 214 | v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm) |
| 215 | Centeringand shutteringincludingstrutting,proppingetc. and removal of form work for: |
| 216 | i) Foundations,footings,bases of column |
| 217 | Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level |
| 218 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
| 219 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 220 | i) Foundations,footings,bases of columns, etc. for mass concrete |
| 221 | Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels |
| 222 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 |
| 223 | Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth |
| 224 | ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH |
| 225 | Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks |
| 226 | Providingandfixing18mmthickgangsawcutmirrorpolished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. |
| 227 | iv) Granite of any colour and shade having Area of slab over 0.50 sqm |
| 228 | Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: |
| 229 | Providing and laying cement plaster on surfaces with Coarse sand including curing etc. |
| 230 | ii) 12mm Cement plaster of mix 1:6 (1 cement: 6 coarse sand) |
| 231 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 232 | Finishing walls with water proofing cement paint of required shade with Two or more coats applied @ 3.84 kg/10 sqm: |
| 233 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 234 | Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Standards and as approved by Engineer-in-charge : |
| 235 | ii) 16mm dia x 400mm long with 75 mm dia x 5 mm thick plate |
| 236 | Installation of supplied 20 KL Tank as per specified drawings as per work description but excluding all works of kerb wall and Gasket for manhole including painting / doping with Shalimastic HD as applicable as per specifications complete. |
| 237 | iii) In earth pit with RCC matt raft as per standard Drg. ENG/314 (with sand filling) |
| 238 | Supply, fabrication, laying and testing of MS, BLACK, ERW, threaded pipes, heavy class conforming to IS 1239, PART I as per IOCL specifications including pipeline fittings like bends, tee etc as required and as directed for Underground pipeline with doping |
| 239 | ii) S/L Threaded U/G HD MS Pipes of 80 mm diawith fittings,doping |
| 240 | iii) S/L Threaded U/G HD MS Pipes of 50 mm diawith fittings,doping |
| 241 | Supply, fabrication, laying and testing of MS, BLACK, ERW, threaded pipes, heavy class conforming to IS 1239, PART I as per IOCL Specifications including pipeline fittings like bends, tee etc as required and as directed for Above Ground pipeline including surface preparation according to standard SSPC ST2 and painting with 2 coats of red oxide zinc phosphate primer and 2 coats of Synthetic enamel / aluminium finish paint as per IOCL specifications |
| 242 | ii) S/L Threaded A/G HD MS Pipes of 80 mm dia with fittings,Painting |
| 243 | iii) S/L Threaded A/G HD MS Pipes of 50 mm dia with fittings,Painting |
| 244 | Supply, fabrication, laying and testing of MS black, ERW welded, pipes, heavy class conforming to IS 1239, PART I as per IOCL specifications including pipeline fittings like bends, tee etc as required and as directed for Underground pipeline with doping |
| 245 | iii) S/L Welded U/G HD MS Pipes of 50mm dia with fittings,doping |
| 246 | Supply and installation of screwed type gun metal valves as per IOC specifications: Gate Valve |
| 247 | ii) S/I Cast Steel class 150 Flanged Ball Valve of50 mm dia with nuts,bolts, gaskets etc as per specifications. |
| 248 | Supply and installation of ‘U’ type CS bend on the vent pipes including painting as per specifications and supplying and brazingwire mesh of 11 mesh per linear centi-meter of non-corrosive metal in two layers on both ends. |
| 249 | ii) Supply & installation of U type CS bend on vent pipe of 50 mm dia |
| 250 | Installation of supplied Multi Product Pumps / Dispensers on pump island as per manufacturers installation manual, drawings, including supplying, providing necessary frame of ISMC 100, foundation bolts, supplying and filling required quantity of dry sand in pit(s) below the pump |
| 251 | i) 2 product - 4 nozzle MPPs/MPDs |
| 252 | Air compressor Supply and installation of horizontal air compressor assembly with delivery pressure of 12 kg/sq cm equipped with pressure gauge, non- return/safety/drain/delivery valves, automatic cut-off switch and suitable electrical connections & all standard accessories, including civil works: |
| 253 | ii) Horizontal air compressor Assembly of 3 HP (160-220 LITRES) including civil works |
| 254 | Tyre Inflator Supply & installation of Digital tyre inflator which is microprocessor based, automatic air pressure controller with solenoid controlled nozzle for automatic fill and release functions. Complete with weather proof cabinet, 3 digit LED displays with backlight illuminations i.e. one for actual tyre pressure and another for set pressure. Air filter, remote controller, cables, PVC hose pipe and working pressure upto 10bar (Excluding civil work for foundation,etc.) |
| 255 | Supply and Laying of 50 mm dia single wall flexible piping system comprising of Non-metallic HDPE (flexible) pipelines as per IOCL specifications and with manufacturer supplied fittings including all bends, tees, elbows, reducers, end connectors at DU & tank side etc and as required for complete underground piping job. The joints in the pipelines, except the end connections at tanks and dispensers shall be made by electro-fusion welding. The pipes shall be suitable for use with petroleum and ethanol blended fuels. The maximum operating pressure shall be 7Kg/sq.cm. Note: The make of HDPE Pipe should be CCOE approved. Pressure testing shall be done before the final backfilling. The civil works for installation viz. excavation, sand filling& back filling etc. shall be paid seperately. All metallic parts in the piping system shall be grounded as per the requirements of EN14125. |
| 256 | Supply and Laying of 80 mm dia single wall flexible piping system comprising of Non-metallic HDPE (flexible) pipelines as per IOCL specifications and with manufacturer supplied fittings including all bends, tees, elbows, reducers, end connectors at DU & tank side etc and as required for complete underground piping job. The joints in the pipelines, except the end connections at tanks and dispensers shall be made by electro-fusion welding. The pipes shall be suitable for use with petroleum and ethanol blended fuels. The maximum operating pressure shall be 7Kg/sq.cm. Note: The make of HDPE Pipe should be CCOE approved. Pressure testing shall be done before the final backfilling. The civil works for installation viz. excavation, sand filling& back filling etc. shall be paid seperately. All metallic parts in the piping system shall be grounded as per the requirements of EN14125. |
| 257 | Transportation of equipmentfrom one location to another location including enroute all taxes, leviesand unloading/loading by a suitable vehicle exclusively for this purpose (In case of tank sameshall be loaded by the tank fabricationcontractor) |
| 258 | vii) Mono/Duo pump/Air Comp/STP/All other pumps - upto 2 nos,0-30 Km |
| 259 | viii) Mono/Duo pump/Air Comp/STP/All other pumps - upto 2 nos, Add extra for every additional Km above 30km |
| 260 | xi) MPD/MPP pumps upto 2 nos., 0-30 Km |
| 261 | xii) MPD/MPP pumps upto 2 nos., Add extra for every additional Km above 30km |
| 262 | Replacing existing manhole gaskets for 15/20/50/70 KL U/G & A/G tanks including disconnecting the pipelines, removing nuts, bolts & manhole cover and supplying and fixing permanite oil gaskets, nuts & bolts and reconnecting the pipeline. |
| 263 | Supply and fixing Pressure Vacuum Valves of 2 inches for fixing to the Vent Pipes of Underground MS tanks. The valve should be in closed position at normal operating pressure of the tank. The Valve shall be capable for activation at set pressure of 3\" ± 0.5 water column to release excess pressure of tank to the atmosphere and open at vacuum of 8\" ± 2.0 water column to induce the atmosphere pressure to the tank. PV valve should be diaphragm of dead weight or spring loadedtype or combination of any. The weight of the PV valve shall not exceed 2.0 kg. top of the valve shall be provided with cover/cap/ weather hood to prevent the entry of rain water. Valve material,Coverand adopter shall be of Aluminium/polypropylene, diaphragm if used should be of Neoprene, O ring should be of rubber/neoprene, Net/Mesh Pressure puppet ,Vacuum puppet,screws and spring should be of stainless steel. Suitable adopter with one end fitted with valve and the other end should have threading for fixing on Vent pipe of 40mm. PV valves shall have: UL 842 certification of CARB approval or test certificate from any Govt.lab. PV valve shall have PESO approval. |
| 264 | Installation of Corporation supplied Standard Submersible Turbine Pump on the existing Manhole Cover as per drawing and direction of Engineer in Charge |
| 265 | CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items |
| 266 | iv) 3 Core x 2.5 sq. mm Copper Cable FRLS |
| 267 | CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compressoncable glands, crimping type lugs and allied jointing materials, etc. all complete as per specificationand direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. |
| 268 | vi) 3 Core x 1.5 sq. mm. |
| 269 | vii) 3 Core x 2.5 sq. mm |
| 270 | Supply of chemical earthing technology (pipe in pipe) for Electrode Design of specified Current Carrying Capacity in kA for 1 second. Crystaline Conductive mixture which is machine pressed in the pipes should not disintegrade or collapse when the outer pipe corrodes. Resistivity of the Material shall be less than 0.2ohm meter when tested by making a 20cm Cube of the Material & checking the resistance across the opposite faces of the cube. Necessary Test certificate shall be submitted. Concentric Earth Electrode Pipe should be MS of IS:1239 quality & hot Dip galvanised of 150 micron. Electrode Material Selection should be as per Clause 9.3: IS-3043. |
| 271 | i) Current Capacity:3kA Primary Conductor(Inner pipe dia-20NB; Electrode Outer Pipe Dia-40NB Length of Concentric Pipes:2M |
| 272 | Supply & drawing/laying, jointing, connecting, testing and commissioning ofearth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : |
| 273 | iii) 50 x 6 mm G.I. Strip |
| 274 | ii) 32 x 6 mm G.I.strip |
| 275 | v) 25 x 3 mm GI strip |
| 276 | Supplying and providing 100mm squarehensel weather proof junction box for emblem pole/ light pole/yard light |
| 277 | PANEL BOARDS AND DISTRIBUTION BOARDS Supply, installation, testing and commissioning of cubicle type power and motor control centre panel fabricated out of 14 SWG sheet steel undergone 7 tank process,dust & vermin proof, floor mounting type, suitable for indoor use having cable entry from the bottom and having following specific components complete, control wiring etc. as per enclosed standard drawing. Any other components/hardware required to complete the panels but not mentioned here shall also be provided. Note: Both incomers should have mechanical interlock for proper & safe operation. The MCCB used for incomer feeder shall have short circuit, overload and earthfault protection and also shunt coil for ESD operation. The Bus Bar support shall be DMC/ SMC/Epoxy moulded. All equipment/components shall be mounted logically to have free access for maintenance, tightening of connections & visual inspection. All the metering equipment shall be Digital & mounted on the panel and size of meter shall be 96 mm x 96 mm. The Bus Bar shall be provided with heat shrunk PVC sleeves & all power terminals shall be stud type with properly shrouding to avoid accidental contact. Neoprene type gasket shall be provided at the doorof the panel. The enclosure of the Panel shall have IP52 degree of protection. 2 Nos earth terminal shall be provided at the Panel frame with extension link for earthing connections. Painting:The under surface shall be prepared by applying a coat of phosphate paint and coat of yellow zinc chromate primer. The under surface shall be made free from all imperfections before undertaking the finishing coat. After preparation of the under surface, the switchboard shall be spray painted with two coats of epoxy based final paint or shall be powder coated. Colour shade of final paint shall be RAL 7032. |
| 278 | Medium RO, Standard drawing No. ENG/IOCL/PDIL-2. List of Componets are: (a) 1 No. MCCB (3P+N) of 100 A, 35 KA with O/L, E/F & S/C Releases for incomer from Electricity Board (b) AC Digital Voltmeter (0-500V) with built in selector switch for incomer from Electricty Board (c) AC Digital Ammeter (0-100A) with built in selector switch for incomer from Electricity Board (d) 1 No. FP, On Load, 100 A, Manually Operated Change over switch suitable for connection of Mains supply and 30 KVA DG Set /5 KW Solar system with required No. of MCCB (100 A,35 KA,3P+N) for change over between Mains supply and DG Set /Solar Supply along with 2 Nos 6A , SP, Control MCB with Indicating lamps. (e) 1 No. MCCB (3P+N) of 100A, 35 KA with UV coilO/L , E/F & S/C Releases for incomer from Electricity Board/DG Set/Solar Supply & 1 No 6A , SP, Control MCB with 3 Nos LED Type (RYB) Indicating lamps (f) 3 Nos 100/5 A CL1 10VA Current Transformers ; PT (50 VA) along with 2 A control fuse link and 1 No. 6A , SP, Control MCB (g) 1 No DP MCB of 40 A, 10 KAfor supply of essential loads (h) 1 No Single Phase Contactor(3NO+3NC) for supply to essential loads (i) 1 No MCB DB Hosuing 6 Nos , 16 A, 10 KA DP MCB as outgoings for essential loads (j) 415 V, TP & N, 125 A, Al Bus Bar (k) 4 Nos MCB (3P+N) of 40 A,10 KA for supply of outgoing feeders 1-4 (l) 9 Nos DP MCB of 10 A, 10 KA in Outgoing Feeder -1 (m) 6 Nos DP MCB of 16 A, 10 KA & 3 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-2 (n) 3 Nos DP MCB of 16 A, 10 KA & 6 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-3 (o) 8 Nos TP MCB of 16 A, 10 KA & 1 Nos TP MCB of 25 A, 10 KA in outgoing Feeder-4 (p) Provision for Termination of Solar Power (Up to 10 KW) Incomer to Essential DB in Panel as per requirement ofIOCL. |
| 279 | Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make |
| 280 | ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire |
| 281 | OCTAGONAL POLES Supply & Fixing of Octagonal Poles of following type (Civil job shall be paid separatly) : |
| 282 | iii) S/E of 5 Meter high galvanised Octagonal pole with top 60mm(A/F), bottom 130mm (A/F) made up of 3 mm thick plate having a base plate of size 210 x 210 x 12 with single arm 1500mm long bracket arm made up of 48 O.D. pipe with EN 8 grade galvanised foundation bolts and anchor plate on suitable concrete foundation as per standard drawings enclosed herein(Civil & Electrical works shall be paid separately) having fixing arrangement for mounting 2 Nos. of 250W Metal halide luminaries (on opposite sides) |
| 283 | Supply, fitting, fixing of arm bracket, tubular type, 38mm/50mm dia on pole including painting, all complete. |
| 284 | ii) S/EArm \" Y \" bracket 38/50mm dia on pole, as per specifications and direction of Engineer in charge |
| 285 | Supplying & drawing inside the poles 3 core 2.5 sq.mm PVC insulated flexible copper conductor, fixing of junction box at the pole base (excluding supply of JB), making all connections on both ends, all complete as per specification and direction of Engineer In-charge. |
| 286 | i) \"Y\" Pole |
| 287 | ii) \"L\" Pole |
| 288 | DISPENSING PUMP CONNECTIONS |
| 289 | ii) Providing dispensing pump power circuit connection with copper conductor single core PVC sheathed wire as per recommendationsof the pump manufacturer (make of pumps: L&T /MIDCO /AVERY / Tatsuno/ Nouvopignone) |
| 290 | Supply and fixing of 100 W LED (Light Emitting Diode) light fixture with fittings and accessories for Yard lighting purpose having IP66 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. |
| 291 | Supply and Installation of 16 SWG MS/GI powder coated weather proof Earthing Box of following size with door and locking arrangement with lock and key. Box to be mounted on ISA 40x40x5 (Painted with black synthetic enamel paint) frame having 2 legs of length 800 mm (500 mm above ground and 300 mm below ground which is to be grouted with PCC 1:2:4). Bottom of box should have opening for incoming earth GI strips all complete, as per specification and direction of Engineer-in-charge. Note: EARTHING BOX in RED should be boldly written over the box. The box should have a hood at the top extending outwards such that no water should seep through inside the box during rainy season to avoid rusting. |
| 292 | i) 450 X 300 X 250 mm |
| 293 | Supply & laying of Heavy Duty type, High compression strength, IP 67 rated (DWC) Double wall corrugated HDPE Conduits as per IS:14930/ IS:16205. Laying includes with GI pull wires inside the conduits & necessary ends to be filled with sealants, of all complete and as per drawing & specification. |
| 294 | ii) 63 mm OD / 50 mm ID |
| 295 | iii) 50 mm OD / 38 mm ID |
| 296 | Supply and Fixing of Discrete LED (Light Emitting Diode) Surface mounted Linear light fixture of following size, having IP 20 protection. class with Pressure Die cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, CCT(Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), Ambient temp-0 to 45Deg Celsius, Driver efficiency > 85%, THD < 10%, Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level <60V DC as per IEC standard, Luminaire lumen = 2100lm. Each lot of Fittings shall have serialnumbers and accompany LM79 / IS 16106 test reports and reference/batchnos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc |
| 297 | i) 20 Watt (1200 mm) |
| 298 | Supply, Installation, Testing and Commissioning of Powerline Conditioner with input voltage and Output Voltage of 380V-415V-440V 3 Phase, Delta/ Star, 1:1 Ratio, Power Factor 0.75 Lead to 0.75 Lag, Outdoor Type (Hermatically Sealed) IP- 65 rated, oil cooled class H insulation and Operating Temperature- 0° C to 45° C, all complete as per relevant IS code (IS 2026, IS 11171), specification and direction of Engineer-in-charge. |
| 299 | viii) 15 KVA |
| 300 | As built Drawing for Cable Route & Earth |
| 301 | As built Drawing forPipline Route in C |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail