Military Engineer Services-MES has published Repair Or Maintenance Of Central Coolers, Package Type Ac Plants And Other Connected Misc Items At Af Station Jaipur. Submission Date for this Tender is 10-02-2023. HVAC Tenders in jaipur Rajasthan. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 27-Jan-2023 | corrigendum | BOQ | 03-02-2023 |
2 | 03-Feb-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 10-02-2023 |
Sl. No. | Item Description |
1 | Comprehensive Maintenance of7.5 Ton Precision Airconditioner Unit installed at NFS building Airforce station Jaipur including complete servicing, cleaning, Gas Charging,PCB Repairing, replacement of capacitor, replacement of unservicable part like compressor, controller, switchgear component, filter driver, all valves complete all as spd and directed.Note: (i) Rate of Spare parts required deemed to be included in quoted rate. (ii) item includes Two full service.(iii) Contractor have to attend any breakdown call withing 6 Hrs otherwise a penalty of Rs. 500 per hours would be imposed. |
2 | Comprehensive Maintenance of Inverter Split type Airconditioner installed at NFS building Airforce station Jaipur including complete servicing, cleaning, Gas Charging and replacement of PCB, capacitor,compressor, condenser or any unservicable partscomplete all as spd and directed.Note: (i) Rate of Spare parts required deemed to be included in quoted rate. (ii) item includes Two full service.(iii) Contractor have to attend any breakdown call withing 6 Hrs otherwise a penalty of Rs. 100 per hours would be imposed. |
3 | Taking down,Desert Cooler from domestic and technical area ofany make, capacity 3000/4500 cfm and refixingin positionafter servicing, cleaning, greasing,replacing old/defective parts etc complete all as specified and directed. Note : Replaced Items will be measured and paid separately. |
4 | Supply and fix onlygrass pad/khas pad (set of 03 pads) in desert cooler of any make and size installed at site complete all as specified and directed. |
5 | Supply and fixing of water pump 1/7 HP submersible type of desert cooler single phase 230 volt complete all as spd and directed. |
6 | Supply and fix water distribution pipe with tee and elbowscomplete all as specified and directed(Each desert cooler set). |
7 | Rewinding of unsercing/burned fan motor of desert cooler with replacement of new copper winding with properinsulation material coating over windindingand cleaningrusted iron portion greasing moving partcomplete all as directed and directed. |
8 | M&L for desert cooler body of size 26X26X36 inch made of 26 Gauge MS sheet , mounting arm for fixing fan motor and provisioning of switch cabinate including painting of complete body complete all as spd and directed. |
9 | Material and labour for servicing/cleaning of complete indoor and out door unit of Split Type Air conditionerof 1.0/1.5 TR capacity by means of adding cleaning solution with water. The cleaning of the condensor and chiller tubes shall be done with use of nylon brushes till the scaling is removed and ensuring its serviceability by rectification / replacement of unserviceable parts and keeping AC in good working condition and specified and as directed by Engineer-in-Charge.Note :- Supply of spares for replacement will be measured and paid separately under relevant item of Sch "A". |
10 | M&L for gas charging freon gas (R-22) for 1.5/2Ton capacity split type AC complete all as specified and directed. |
11 | M&L for gas Top up onAC 1.5/2 ton capacity any typecomplete all as specified and directed. |
12 | M&L for repair of PCB/IC/Relay/ Transformer of 1.5/2.0 TR capacity split type AC, single phase. |
13 | All as per Item Ser No. 12.00 above but for 165/180/310 Ltrs capacity Refrigerator complete all as specified and directed. |
14 | All as per Item Ser No. 12.00 above but for 40/80 Ltrs capacity Water cooler complete all as specified and directed. |
15 | All as per Item Ser No. 12.00 above but For 410 Ltr Cap deep freezer complete all as specified and directed. |
16 | M&L gas charging freon gas R-22 after flushing of system completeand testing the system with N2 gas for Refrigerator 165/180/310/410 Ltrs capacityall as specified and directed. |
17 | All as per Item Ser No. 16.00 above but Water cooler any type and capacity.complete all as specified and directed. |
18 | S & F in repair condensor coil for refrigerator of 165/180/310 Ltrs capacity complete all as specified and directed. |
19 | S&F in replacement sealed unit compressor for Water cooler40/80 Ltrs capacity of make Usha,Voltas,LG complete all as specified and directed. |
20 | All as per Item Ser No. 19.00 above for, compressor for refrigerator of 165/180 Ltrs capacity complete all as specified and directed. |
21 | All as per Item Ser No. 19.00 above butcompressor for refrigerator of 310 Ltrs capacity complete all as specified and directed. |
22 | All as per Item Ser No. 19.00 above butcompressor for deep freezer of 410 Ltrs capacity complete all as specified and directed. |
23 | All as per Item Ser No. 19.00 above but hermitically sealed compressorfor window/split type ACof 1.5 ton capacity complete all as specified and directed. |
24 | All as per Item Ser No. 19.00 above but hermitically sealed compressorfor window /spit type ACof 2 ton Capacity complete all as specified and directed. . |
25 | S & F in repair thermostate of refrigerator 165/180/310/410 ltrs capacity complete all as specified and directed. |
26 | All as per Item Ser No. 25.00 above butwater cooler complete all as specified and directed. |
27 | Supply and fix in repair starting capacitor100/120 MFD complete all as specified and directed. |
28 | M&L in repair for fan blade complete set for havingsplit AC 1.5 Ton capacity complete all as specified and directed. |
29 | Supply and fix in replacement blower motor complete for window/split typeAC 1.5/2 ton capacity complete all as specified and directed. |
30 | All as per Ser.Item No. 29.00 above but Refrigerator 165/180 Ltrscomplete all as specified and directed. |
31 | Supply and fix thermostate complete forsplit/WindowtypeAC 1.5 ton capacity complete all as specified and directed. |
32 | M&L in repair for replacement ofover load relay protector/assembly for refrigerator (any make)165/180 ltrs capacity complete all as specified and directed. |
33 | All as per Item Ser No. 32.00 above but 310 ltrs capacity complete all as specified and directed. |
34 | All as per item ser No 32.00 above but for AC 1.5 ton window/split type complete all as specified and directed. |
35 | All as per item ser No 32.00 above but for water cooler capacity 40/80 Ltrs complete all as specified and directed. |
36 | Supply and fix in replacement running capacitor 50 MFD for 1.5/2 ton AC complete all as specified and directed. |
37 | S&F in repair insulation for split AC 1.5/2 Ton copper pipe complete all as specified and directed. |
38 | Supply and fixing in repair water pump for air ducting cooler ( cap 18000cfm) ,40 watt, 50Hz single phase submersible type complete all as spd and directed. |
39 | Servicing of Air ducting cooler capacity 18000 cfm and refixingin positionafter servicing, cleaning, greasing,replacing old/defective parts etc complete all as specified and directed. Note : Minor replaced Items will be included in sch item . |
40 | M&L for central cooler base body of sizeinch made of 26 Gauge MS sheet including mounting arm for fixing fan motor including painting of complete body complete all as spd and directed. |