Tender For Construction Of New Girls Hostel Building (G Plus 5) And Multi Utility Building (Renovation) At Govt Medical College Koraput., koraput-Odisha

Civil Engineering Department has published Tender For Construction Of New Girls Hostel Building (G Plus 5) And Multi Utility Building (Renovation) At Govt Medical College Koraput.. Submission Date for this Tender is 27-01-2023. Building Repair Tenders in koraput Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

35736204
Tender For Construction Of New Girls Hostel Building (G Plus 5) And Multi Utility Building (Renovation) At Govt Medical College Koraput.
Open Tender
Indian
Odisha
koraput
27-01-2023

Tender Details

Construction Of New Girls Hostel Building (G Plus 5) And Multi Utility Building (Renovation) At Govt Medical College Koraput.

Key Value

Document Fees
INR 10000 /-
EMD
INR 1847000.0 /-
Tender Value
INR 18.46 Crore /-

BOQ Items

Name of Work: Construction of New Girls Hostel Building (G+5) & Multi Utility Building (Renovation) at Govt Medical College Koraput.
Sl. No. Item Description
1CIVIL WORK Providing jungle cutting uprooting buses below 1.00m girth with cost of all labour and T&P required for the work etc. complete.
2SITE CLEARANCE
3Dismantling brick or stone masonry in lime or cement mortar above 3m height including stacking the useful materials for re-use and removing the debris with in 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge.
4Under 3.0mt (MUB)
5Above3.0mt (MUB)
6SITE CLEARANCE
7Dismantling and removing R.C.C. columns beams slab staircase landing lintels including stacking the useful materials for reuse and removing the debris within 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge.
8Stilt floor (MUB)
9Dismantling and removing R.C.C. Chajja, Shelves, fins and parapet including stacking the useful materials for reuse and removing the debris within 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge.
10Stilt floor (MUB)
11Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge.
12Stilt floor (MUB)
13Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.50m initial lift including rough dressing breaking clods maximum 5cm to 7cm & laying in layers not exceeding 0.3m depth for the work complete including shoring, shuttering & dewatering (if required) with cost of all Labour, Labour cess ,Hire & Running charges of thewater pumps, Sundries, T & P required for the work complete as directed by the Engineer- in- charge.
14All type of soil (Hostel)
15All type of soil (MUB)
16RETAINING WALL
17SITE CLEARANCE
18Carriage of earth by mechanical means with cost of all labour and T&P required for the work etc. complete. (Upto 5km).
19MUB
20SITE CLEARANCE
21Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-in-charge.
22HOSTEL BUILDING
23MUB
24Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. in depth with all lead and lift including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,labour cess, sundries, T&P required for the work etc. complete in all respect as per direction by the Engineer in charge. (Measurement will be taken on finished compacted section only).
25HOSTEL BUILDING
26MUB
27RETAINING WALL
28Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment).
29HOSTEL BUILDING
30MUB building
31Providing and lying plain cement concrete of proportion (1:3:6) in foundation and floors using Portlandslag cement (PSC) with 40 mm. Size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties and taxes all materials and cost all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per the instruction of the Engineer-in-Charge.
32HOSTEL BUILDING
33MUB building
34RETAINING WALL
35Providing and lying plain cement concrete of proportion (1:3:6) in foundation and floorsusing Portland Slag Cement (PSC) with 12mm. Size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties and taxes all materials and cost all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per specification anddirection of Engineer-in-charge.
36HOSTEL BUILDING
37Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed andcleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portlandslag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.
38HOSTEL BUILDING
39Footing
40Column up to PlLvl
41Tie/Plinth Beam
42MUB
43Footing
44Column up to PlLvl
45Tie/Plinth Beam
46RETAINING WALL
47Footing
48Retaining wall base 350mm top 230mm
49Column up to Roof Lvl :-
50HOSTEL BUILDING
51Stilt floor
52First Floor
53Second Floor
54Third Floor
55Fourth Floor
56Fifth Floor
57Mumty Floor
58MUB
59Ground floor
60LINTEL :-
61HOSTEL BUILDING
62Stilt floor
63First Floor
64Second Floor
65Third Floor
66Fourth Floor
67Fifth Floor
68Mumty Floor
69MUB
70Ground floor
71CHAJJA:-
72HOSTEL BUILDING
73Stilt floor
74First Floor
75Second Floor
76Third Floor
77Fourth Floor
78Fifth Floor
79Mumty Floor
80MUB
81Ground floor
82ROOF BEAM:-
83HOSTEL BUILDING
84Stilt floor
85First Floor
86Second Floor
87Third Floor
88Fourth Floor
89Fifth Floor
90Mumty Floor
91MUB
92Ground floor
93ROOF SLAB:-
94HOSTEL BUILDING
95Stilt floor
96First Floor
97Second Floor
98Third Floor
99Fourth Floor
100Fifth Floor
101Mumty Floor
102MUB
103Ground floor
104STAIRCASE:-
105HOSTEL BUILDING
106Stilt floor
107First Floor
108Second Floor
109Third Floor
110Fourth Floor
111Fifth Floor
112LIFT WALL:-
113HOSTEL BUILDING
114Stilt floor
115First Floor
116Second Floor
117Third Floor
118Fourth Floor
119Fifth Floor
120Mumty Floor
121SHELVES (37.5mm):-
122HOSTEL BUILDING
123Stilt floor
124First Floor
125Second Floor
126Third Floor
127Fourth Floor
128Fifth Floor
129Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / TATA / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. includingbending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge.
130HOSTEL BUILDING
131Stilt floor
132First Floor
133Second floor
134Third floor
135Fourth floor
136Fifth floor
137Terrace Floor
138MUB
139RETAINING WALL
140Providing weepholes in retaining wall, drain covers etc with 50mm pipe
141RETAINING WALL
142Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.
143HOSTEL BUILDING
144MUB
145Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.
146HOSTEL BUILDING
147Stilt floor
148First Floor
149Second floor
150Third floor
151Fourth floor
152Fifth floor
153Terrace Floor
154MUB
155Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge.
156HOSTEL BUILDING
157Stilt floor
158First Floor
159Second floor
160Third floor
161Fourth floor
162Fifth floor
163MUB
164Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
165HOSTEL BUILDING
166Stilt floor
167First Floor
168Second floor
169Third floor
170Fourth floor
171Fifth floor
172Terrace Floor
173MUB
174Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
175HOSTEL BUILDING
176Stilt floor
177First Floor
178Second floor
179Third floor
180Fourth floor
181Fifth floor
182Terrace Floor
183MUB
184Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
185HOSTEL BUILDING
186Stilt floor
187First Floor
188Second floor
189Third floor
190Fourth floor
191Fifth floor
192Terrace Floor
193MUB
194Supplying, fitting and fixing vetrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Color / Printed series (Homogenous) of approved make (OASIS / SOMANY/ KAJARIA or equivalent) in floors on 20mm thick bed of C.M. (1:4) (1cement:4course sand) and filling the joint with white cement mixed with pigment to match the shades of the tile including cost of all materials, labour, labour cess, T&P etc. required for the work completein all respect as directed by the Engineer in charge.
195HOSTEL BUILDING
196Stilt floor
197First Floor
198Second floor
199Third floor
200Fourth floor
201Fifth floor
202MUB
203Providing, fitting, fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Color / Printed series (Homogenous)of approved make (OASIS / SOMANY/ KAJARIA or equivalent )as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects.
204HOSTEL BUILDING
205Stilt floor
206First Floor
207Second floor
208Third floor
209Fourth floor
210Fifth floor
211MUB
212Providing and fixing 20mm thick mirror polished granite stone slab, machine cut stone (sample of granite should be approved by EIC) for kitchen platforms, vanity counters, facias and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge, making gas pipe hole etc. laid over 25mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights.In all floors and all heights.
213HOSTEL BUILDING
214Stilt floor
215First Floor
216Second floor
217Third floor
218Fourth floor
219Fifth floor
220Terrace floor
221MUB
222Fixing granite tiles of approved dimension area above 0.1 up to 0.4 sqm (10mm thick) in Dados, treads of steps and landing on 12mm thick cement mortar (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects as per direction of Engineer-in-Charge.
223HOSTEL BUILDING
224Stilt floor
225First Floor
226Second floor
227Third floor
228Fourth floor
229Fifth floor
230Terrace floor
231MUB
232Providing and layinganti-skid Matte Finish Vetrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 300mm x 300mm plain (Ivory)of approved make (OASIS / SOMANY/ KAJARIA or equivalent ) in floors on 20mm thick bed of C.M. (1:4) (1cement:4course sand) and filling the joint with white cement mixed with pigment to match the shades of the tileincluding cost of all materials, labour, labour cess, T&P etc. required for the work completein all respect as directed by the Engineer in charge.
233HOSTEL BUILDING
234MUB
235Fixing of Ceramic Glazed Wall Tiles of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13753 of size 30cm x 20cm / 20cm x 20cm special plain / printed series in dados skirting & riser of steps on 12mm thick cement plaster 1:3 joined with neat cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance,royalties of all materials, labour with T&P complete in all respects as per direction of Engineer-in-Charge.
236HOSTEL BUILDING
237MUB
238Fixing of Chequered tiles of premium grade having thickness 7mm to 8mm confirming to IS 13755 of size 30cm x 30cm special plain / printed series in floors over 20mm thick bed of cement mortar 1:4 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, taxes & royalties of all materials, labour with T&P complete in all respects as per direction of Engineer-in-Charge.
239HOSTEL BUILDING
240Providing fitting fixing of inter locked paver block of size 80 mm thick and filling the joints with sand of approvedv quality including rubbing & polishing etc comleteincluding costof all materials, labour with T&P etc. complete in all respect.
241HOSTEL BUILDING
242MUB
243Dressed seasoned sal woodworkframed andfixedinframesofdoors&windows including cost,conveyanceofall materials and cost of labour for fitting, fixing etc.complete as per the instruction of Engineer-in-Charge .
244HOSTEL BUILDING
245Stilt floor
246First Floor
247Second floor
248Third floor
249Fourth floor
250Fifth floor
251MUB
252Providing and fixing ISI marked32mm flush door shutters with 1mm laminates pasted both side confirming to IS 2202(Part1) including ISI marked necessary hardware fitting with approved colour paint over a coat of primer etc and hardware fittings such as, SS Concil Hinges (5"),stopper,Door magnet,SS Tower bolt,Pull handle/Mortise lock Handle,Cylinder coin & knob key & knob ,SS lock body and Door closer etc. includingcost of all labours, materials, conveyance, hardware fixing,loading and unloading, all taxes and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge.
253HOSTEL BUILDING
254Stilt floor
255First Floor
256Second floor
257Third floor
258Fourth floor
259Fifth floor
260MUB
261Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride(UPVC) ( FENESTA / NCL VEKA LTD.)Three Track - Three Panel sliding window– 60- Series duly manufactured using UPVC reinforced profiles of 108mm x 45 mm x 2.5 mm for outer frames and Window Sash of 39 mm x 58 mm x 2.5 mmcapable of mounting singleglazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window frame shall be fitted with 6 mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistantand the system is to be installed using Reinforced Large Coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges, materials andproduct conforming to ASTM D 638-14,EN-477-95 and other applicable codes and standards.
262HOSTEL BUILDING
263Stilt floor
264First floor
265Second floor
266Third floor
267Fourth floor
268Fifth floor
269MUB
270Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and designwith cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge.
271HOSTEL BUILDING
272Stilt floor
273First Floor
274Second floor
275Third floor
276Fourth floor
277Fifth floor
278Terrace
279MUB
280Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge.
281HOSTEL BUILDING
282Stilt floor
283First Floor
284Second floor
285Third floor
286Fourth floor
287Fifth floor
288Terrace Floor
289MUB
290Painting two coats with approved antifungal weather seal paints (ISI) of approved colour, shade on wall surface over a coat of wall primer(ISI) water bound including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour,labour cess with T&P etc, complete as per specification & direction of Engineer-in-charge.
291HOSTEL BUILDING
292Stilt floor
293First Floor
294Second floor
295Third floor
296Fourth floor
297Fifth floor
298Terrace Floor
299MUB
300Finishing plastered surfaces of walls with water based wall putty of approved make and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge.
301HOSTEL BUILDING
302Stilt floor
303First Floor
304Second floor
305Third floor
306Fourth floor
307Fifth floor
308Terrace Floor
309MUB
310Painting two coats with plastic emulsion paint "Royale Shyne"to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge.
311HOSTEL BUILDING
312Stilt floor
313First Floor
314Second floor
315Third floor
316Fourth floor
317Fifth floor
318Terrace Floor
319MUB
320Painting two coat with approved synthetic enamel paint to new wood & iron work over a coat of Red oxide primer including cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge.
321HOSTEL BUILDING
322Stilt floor
323First Floor
324Second floor
325Third floor
326Fourth floor
327Fifth floor
328Terrace Floor
329MUB
330Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance of all materials, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge.
331HOSTEL BUILDING
332Stilt floor
333First Floor
334Second floor
335Third floor
336Fourth floor
337Fifth floor
338MUB
339Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well ramed, consolidated and grouted with fine sand and finishing the top smooth including shuttering at the edges, excavation and disposing of surplus earth with a lead of 100m.
340HOSTEL BUILDING
341MUB
342Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge.
343HOSTEL BUILDING
344Terraace Floor
345MUB
346Supply of all materials & laying the waterproofing material of Dr.Fixit torch shield P3160(3mm)with its primer 2 coats or equivalent water proofing material after drying cleaning the concrete surface over the concrete floor/roof/ balcony/ sunken and dado upto 1"6" in wall including cleaning, applying and mending as per specification including cost,conveyance, taxes, royalities of all materials to work site etc.all complete as per the direction of the Engineer-in-charge.
347Terraace Floor
348Providing, and applying two coat of primer 7E in both surface of expansion joint followed by applying polysulphide sealant Thioflex 600 on vertical joint surface after proper fixing of the necessary backup materialsas specified including cost ,conveyance ,taxes of all materials ,Labour, transportation charges etc. complete as per specification and direction of the Engineer-in-charge.
349Manufacturing, Providing and Fixing of (Glass Fibre ReinforcedConcrete) GFRC Jali/ Screen, make ""Samudyam or equivalent"" of thickness 25mm+/- 5mm with border thckness 50 +/- 10mm pattern, design and color of approved make to be fixed on/between RCC/Block work column or structural work with dry fixing method with appropriate frame work, using fastners and necessary hardware in building facade. The element shall be made from 53 grade portland cement make Birla/ JK cement or equivalent, quartz, fine silica sand, alkali resistant glass fibre make "OC" or equivalent, super plasticizer/ adhesives (make _BASF or equivalent) polymers and UV resistant synthetic inorganic pigments shall be used for pigmentation make " BAY FERROX" or equivalent. The material casting shall take place in synthetic rubber/ FRP mould manufactured by mould toolof revex/ reckli or equivalent.
350Stilt floor
351First floor
352Second floor
353Thrd floor
354Fourth floor
355Fifth floor
356E.I. WORK INTERNAL WIRING.( Make of wire Finolex/ L&T / Anchor / Havels / V Guard /RR/eq make) Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit (NORPACK/Eq make) with 6 Amp, 250 V clip in type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size ,with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge.Group C
357Recessed wiring to secondary light pointlooped from primary light point with 1.5sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduitwith 1.5sqmm FR PVC insulated single core multistrand copper conductor for running earth including3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer in charge. ) Average Length: 3mtr
358Recessed wiring to ceiling fan point with 1.5sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduit (NORPACK/Eq make)with 6Amp 250V Modular Switch,Stepped type Moudular Regulator, Base & Cover with 1.5sqmm FR PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge.
359Recessed wiringfor 5 / 6 amp socket outletwith6Amp, 250 V clip in type modular switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on same switch board as per direction of Engineer in Charge.
360Recessed wiringfor 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit (NORPACK/Eq make) with 6Amp, 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable size ,with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection on separate board as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels / V Guard )
361Recessed wiringfor2 x 6 amp socket outlet controlled by 2 nos6Amp, 250 V clip in type switch ISI markedmounted on single G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on separate board as per direction of Engineer in Charge.
362Recessed wiringfor 6 pin 16 amp socket outletwith 16Amp, 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection as per direction of Engineer in Charge.
363PointwiringforProjector/A.C socket outlet with 16A plug socketand 16Acontrol switch atnearest separate location.
364Recessed wiringfor A.Csocket outletwith 20 amp SPN, industrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure indusrial socket ,20A SP MCBincluding all accesories and connection as per direction of Engineer in Charge.
365SUBMAIN.
366Recessed wiring to submain in 4 x 16sq.mmFR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 50 mm dia non-metalic heavy duty PVC conduit(NORPACK/Eq make) along with 2 x 10 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (PDB)
367Recessed wiring to submain in 4 x 10 sq.mmFR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 40 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick (NORPACK/Eq make) along with 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(For PDB )
368Recessed wiring to submain in 4 x 6sq.mmFR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 4.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (For LDB)
369Recessed wiring to submain in 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 25 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick (NORPACK/Eq make) along with 1 x 4.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (For EDB & 2TR AC)
370Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.
371Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick (NORPACK/Eq make) along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.
372Recessed wiring to submain in 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick (NORPACK/Eq make) along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.
373DISTRIBUTION BOARD .L&T/ Hager/ Legrand/ Siemens/ Panasonic/Eq make
374Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ Isolator)
3754 way (4 + 12) TPN double doorhorizontal type
3766 way (4 + 18 ), TPN , MCB DB double doorhorizontal type
377Supply and fixing of single pole MCB with sheet steel enclosure, distribution board, on surface /recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, phosphate and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ ISOLATOR)
3784 way SPN , MCB DB double door
3798 way SPN , MCB DB double door
3808 way SPN , MCB DB double door
38112 way SPN , MCB DB double door
382Supply and fixing of following rating 240 V Minature Circuit Breaker (MCB) having a sensitivity current up to 10kA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required.
3836 amp to 32 amp rating SP MCB , "c" series, 10KA breaking capacity
384Supply and fixing of following rating 240 V Residual Current Breaker with Overcurrent protection (RCBO) having a sensitivity current up to 100mA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required.
38525 to 40 amp rating DP RCBO, 30mA
38625 amp rating FP RCBO, 30mA
38732 amp rating FP RCBO, 30mA
38840 amp rating FP RCBO, 100/300 mA
38963 amp rating FP RCBO, 100/300 mA
390CABLE .RR/KEI/eq make
391Supplyof one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of following sizes of cable as required.
3923.5 C x 300 sq.mm Al
3933.5 C x185sq.mm Al
3943.5 C x150sq.mm Al
3953.5 C x95sq.mm Al
3963.5 C x70sq.mm Al
3973.5 C x 50 sq.mm Al
3983.5 C x 25 sq.mm Al
3994 C x 16 sq.mm Al
400Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation, sand cushing, protective covering and refilling the trench etc. as required.
401Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size excedding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc. as required.
402Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size excedding 120 sq.mm but not exceeding 400 sq.mm direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc. as required.
403Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground in the same trench in one tier horizontal formation including excavation , sand cushining protective covering and refilling the trench etc. as required.
404Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground in the same trench in one tier horizontal formation including excavation , sand cushining protective covering and refilling the trench etc. as required.
405Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size excedding 120 sq.mm but not exceeding 400 sq.mm direct in ground in the same trench in one tier horizontal formation including excavation , sand cushining protective covering and refilling the trench etc. as required.
406Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground in the existing RCC/HUME/STONEWARE/METAL pipe as required.
407Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade ofsize exceeding 25 sq.mm but not exceeding 400 sq.mm in the existing RCC/HUME/STONEWARE/METAL pipe as required.
408Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface as required.
409Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm on surface as required.
410Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm on surface as required.
411END TERMINATION
412Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.
4133.5 C x 300 sq.mm Al
4143.5 C x185sq.mm Al
4153.5 C x150sq.mm Al
4163.5 C x95sq.mm Al
4173.5 C x70sq.mm Al
4183.5 C x 50 sq.mm Al
4193.5 C x 25 sq.mm Al
4204 C x 16 sq.mm Al
421PANEL:L&T/Hager/Siemens/Legrand/eq make
422Supply, installation,testing & commissioning of floor mounting front operated front access extensible type cubicle panel totally enclosed, dust and vermin proof with IP-42 /55 protection with hinged and lockabale doors.CRCA sheets including Busbars,interconnections,tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35KA symmetrical for 1 sec at 415 V complete as per specifications, as required and as below : All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used.
423MAIN LT PANEL with 800A 4P Micro Processor Based EDO ACB (50kA)-1 Nos as incomer, 630A 4P MCCB (50kA) -3 Nos, 200A 4P MCCB (50kA) -2 Nos, 63A 4P MCB-2 Nos, 32A 2P MCB-6 Nosas Outgoing.
424MAIN ESSENTIAL PANEL with 200A 4P C/O Switch -1 No &200A 4P MCCB (50kA) -1 No as incomer, 125A 4P MCCB (36kA) - 2 No, 100A 4P MCCB (36kA) - 3 Nos, 63A 4P MCB- 2 Nos, 32A 2P MCB-6 Nos as Outgoing.
425MAIN NON-ESSENTIAL PANEL with 800A 4P C/O Switch -1 No &630A 4P MCCB (50kA) -1 No as incomer, 200A 4P MCCB (36kA) - 3 No, 125A 4P MCCB (36kA) - 2 Nos, 63A 4P MCB- 2 Nos, 32A 2P MCB-6 Nos as Outgoing.
426ZONE-1/3 PANEL (ESSENTIAL) with 100A 4P MCCB (36kA) -1 No as incomer, 40A 4P MCB- 2 Nos, 32A 4P MCB- 8 Nos, 32A 2P MCB-6 Nos as Outgoing.
427ZONE-2 PANEL (ESSENTIAL) with 125A 4P MCCB (36kA) -1 No as incomer, 40A 4P MCB- 3 Nos, 32A 4P MCB- 11 Nos, 32A 2P MCB-6 Nos as Outgoing.
428ZONE-1/2 PANEL (NON-ESSENTIAL) with 200A 4P MCCB (36kA) -1 No as incomer, 63A 4P MCB- 6 Nos, 40A 4P MCB- 10 Nos, 32A 2P MCB- 6 Nos as Outgoing.
429ZONE-3 PANEL (NON-ESSENTIAL) with 125A 4P MCCB (36kA) -1 No as incomer, 63A 4P MCB- 6 Nos, 40A 4P MCB- 2 Nos,32A 2P MCB- 6 Nos as Outgoing.
430EXTERNAL LIGHT PANEL with 63A 4P MCB- 1 No as incomer, 32A 4P MCB- 3 Nos, 32A 2P MCB-9 Nosas Outgoing.
431Automatic Power Factor Correction Panel of 220 kVAR capacity suitable for 440 Volts 3 phase 50 c/s & having APP type heavy duty 525v , self fusing, low loss, self healing, resin bonded without oil, three phase delta connected capacitors (confirming to IS:2834 IS:13346 IEC-831/1-2, & IEC-439(1-2), housed in alluminum cans & having current limiting contacts circuit to suppress switching in rush current & having 12 step microprocessor based APFC relay with digital displaycontrolling capacitors of rating5,10,20, 25 & 50 kVAr for improvement of targeted P.F. of the system & provided with 630 Amps 4P MCCB (50kA) and set of 600/5 CTs with Digital Ammeter and selector switch, capacitor duty contactors with 3Pole MCCB of suitable rating , auto manual selector switch, ON/OFF indicating lamp and push button, 1 No 800/5 CT in the the main panel, including interconnection and control wiring with copper cable etc. complete with 14% detuned reactor as required.10kVArshall be of fixed type.
432MAIN PANEL with 200A 4P C/O Switch, 160A 4P MCCB (36kA) - 1 No as incomer, 40A 4P MCB - 5 Nos followed by 10-40A 3P kWH Energy Meter, 32A 2P MCB- 12 Nos followed by 5-30A 1P kWH Energy Meter with 32A DP Contactor & Timer- 1 Nos as Outgoing and 3nos 160/5A CT, 0-160A Digital Ammeter and 160A aluminium Bus Bars.
433EARTHING
434Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (But wih out charcoal and salt) as required.
435Earthing with G.I. earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (But wih out charcoal and salt) as required.
436Extra for using salt and charcoal for G.I or copper plate earth as required
437Providing and fixing 25 mm x 5 mm Copper strip in 40 mm dia G.I. pipe from earth electrode as required.
438Supplying and laying 25 mm x 5 mm copper strip on surface or in recess for connection etc as required.
439Supplying and laying 25 mm x 6 mm G.I earth strip ISI marked at 0.5 meter below ground level as strip earth electrode including soldering etc. as required.
440Supplying and laying 25 mm x 5 mm G.I earth strip ISI marked on surface or in recess for connection etc as required.
441Providing and fixing 8 SWG (4 mm) dia copper wire on surface or in recess for loop earthing as required.
442LIGHTNING ARRESTOR
443Providing and fixing of lightning conductor finial made of 25mm dia 300 mm long, G.I tube,having single prong at top,with 85mm dia 6 mm thick G.I base plate including holes etc. complete asrequired.
444Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)
445Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)
446Providing and fixing of testing joint, made of 20 mm x 3 mm thick G.I. strip, 125 long with 4 nos of G.I. bolts, check nuts and spring washer etc complete as required.
447Providing and fixing of lightning conductor finial made of 25mm dia 300 mm long, copper tube,having single prong at top,with 85mm dia 3 mm thick copper base plate including holes etc. complete asrequired
448Providing and fixing of copper tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)
449Providing and fixing of copper tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)
450Providing and fixing of testing joint, made of 20 mm x 3 mm thick Copper strip, 125 long with 4 nos of G.I. bolts, check nuts and spring washer etc complete as required.
451Reveting, sweating and soldering of copper / G.I. tape ( with another copper / G.I. tape, base of the finial or any other metallic object) as required
452Providing and laying of G.I. tape 32 mm x 6 mm from earth electrode directly in ground as required.
453Providing and laying of copper tape 32 mm x 6 mm from earth electrode directly in ground as required.
454Earthing with G.I. earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (But wih out charcoal and salt) as required.
455Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (But wih out charcoal and salt) as required.
456Extra for using salt and charcoal for G.I or copper plate earth as required
457FIXTURE
458Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc. directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required.
459Surface mounted indoor type 18W SINGLE LED TUBELuminaire with LED Lamp Similar to WIPRO Cat No. WIO921208 Panaonic(Eq model)/Crompton(Eq model)//Halonix(Eq model)/Bajaj(Eq model)/equivalent make.
460Surface mounted outdoor type 40W LED TUBEwith LED Lamp Similar to WIPRO Cat No. LE20-491-XXX-57-G1 Panaonic(Eq model)/Crompton(Eq model)//Halonix(Eq model)/Bajaj(Eq model)/equivalent make.
461Surface mounted indoor type 36W 2"x2" Square LED Luminaire with LED Lamp Similar to WIPRO Cat No. CRCO10S036HP57G2 Panaonic(Eq model)/Crompton(Eq model)//Halonix(Eq model)/Bajaj(Eq model)/equivalent make.
462Surface mounted indoor type 6W ROUND LED Luminaire with LED Lamp Similar to WIPRO Cat No. LD80-350-XXX-60-SM Panaonic(Eq model)/Crompton(Eq model)//Halonix(Eq model)/Bajaj(Eq model)/equivalent make.
463Surface mounted indoor type 12W ROUND LED Luminaire with LED Lamp Similar to WIPRO Cat No. LD80-101-XXX-60-SM Panaonic(Eq model)/Crompton(Eq model)//Halonix(Eq model)/equivalent make.
464Surface mounted indoor type 15W ROUND LED Luminaire with LED Lamp Similar to WIPRO Cat No. LD80-131-XXX-60-SM Panaonic(Eq model)/Crompton(Eq model)//Halonix(Eq model)/Bajaj(Eq model)/equivalent make.
465Surface mounted indoor type 10W BULK HEADLED Luminaire with LED Lamp Similar to WIPRO Cat No. LW07-141-XXX-57-XX Panaonic(Eq model)/Crompton(Eq model)//Halonix(Eq model)/equivalent make.
466Surface mounted indoor type 10W MIRRORLED Luminaire with LED Lamp Similar to WIPRO Cat No. LL20-111-XXX-65NE3 Panaonic(Eq model)/Crompton(Eq model)//Halonix(Eq model)/Bajaj(Eq model)/equivalent make.
467SITC of indoor type LED SKIRTING LIGHT mounted on G.I modular box with face plate & cover of suitable size , Similar to LEGRAND MYRIUS Cat No. 673036 or equivalent.
468Supplying and fixing of Call Bell / Buzzer ISI marked suitable for DC /AC single phase 230 volts complete as required.
469Supply, Installation, Testing and Commissioning of ceiling fan 1200mm sweep, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required.(Bjaj/Crompton/Havells/Eq make)
470Supply, Installation, testing and commissioning of exhaust fan of 300 mm sweep 900 rpm in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etcas required.
471Supply, Installation, testing and commissioning of exhaust fan of 150 mm sweep 900 rpm in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etcas required.
472Providing and fixing extra down rod of 50 cm length G.I. pipe 20 mm dia heavy gauge including painting etc as required . ( more than 5 cm lenght shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored
473DATA, TELEPHONE & TELEVISION
474Recessed wiring to telephone pointwithclip in type modular telephone socket (RJ 11) ISI markedmounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge.
475Recessed wiring to television point with clip in type modular television socket ISI markedmounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge.
476Recessed wiring to LAN pointwithclip in type modular lan socket (RJ45) ISI markedmounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge.
477Supplying and fixing of 16 / 18 SWG metal box of 200 mm x 150 mm x 60 mm deepon surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required.
478Supplying and fixing of 25mm PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required.
479Supplying and drawing one pair, 0.5 sq.mm FR PVC insulated coper conductor, unarmoured telephone cable in existing surface / recessedPVC conduit as required.
480Supply and drawing of TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated shielded with fine tined copper braid & protected with FR PVC sheath inexisting surface / recessed STEEL / PVC conduit as required.
481Supplying and drawing UTP 4 pairLAN cat-6 cable in the existing surface / recessed PVC conduit as required.
482Supply & Fixing of 9U Rack single section glass door with cable manager, fan & AC Distribution.Complete as required .(Make-VALRACK, VEROPRESIDENT, HCL)
483Supplying, Installing, Testing & commissioning of 24 port distribution data managed 2 layer giga switch suitable for rack mounting. CISCO
484Supplying,Installing, Testing & commissioning of 24 port patch panel suitable for rack mounting D-LINK/HP/3Com or Equivalent.
485Supply and fixing of 10 pair telephone tag box with KRONE terminal
486EXTERNAL LIGHTING
4877M long G.I.octagonal pole complete with RCC foundation, required G.I base plate , single-arm of ERW galvanised pipe 30mm - 1M length,providingGI pipes for cable entry junction box with prewired 6 Amp SP MCB, loop-in -loop-out , terminal block, wiring with copper wire upto the fitting etc. complete
4884M long G.I.octagonal pole complete with RCC foundation, required G.I base plate , Single-arm of ERW galvanised pipe 30mm - 1M length,providingGI pipes for cable entry junction box with prewired 6 Amp SP MCB, loop-in -loop-out , terminal block, wiring with copper wire upto the fitting etc. complete
489Supply , fixing& termination of OutdoorStreet Light LEDLuminaire with 72w LED Lamp similar to WIPRO Cat No.LR02-781-XXX-57-G2 / JAQUAR / Philips / Halonix / Panasonic or equivalent.
490Supply , fixing& termination of OutdoorStreet Light LEDLuminaire with 40w LED Lamp similar to WIPRO Cat No.LR02-451-XXX-57-G1or equivalent.
491Supply &fixing ofBUSH LIGHTsuitable for LED lamp Equiv. to WIPRO LF05-600-036-27-XX . With Junction Box.
492Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.
493Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of 2Cx 6 sq.mm Al.direct in ground in the same trench in one tier horizontal formation including excavation , sand cushining protective covering and refilling the trench etc. as required.
494Supplying and making end termination with brass compression gland and aluminum lugs for 2C x 6 sq.mm of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required.
495Supplying and fixing of 16 / 18 SWG metal box of 200 mm x 150 mm x 60 mm deepon surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required.
496Supplying and fixing ofof 50mm G.I pipe(Medium Class) along with accessories ingroundincluding cutting & making good the sameas required.
497Supply, delivery & installation of GI coil earthing made out of 8 swg GI wire closely wound in shape of a helical coil of 50mm diameter with 115 numbers of turns including excavation of earthpit of size 800x 800x 1500mm in all kinds of soil, back filling the excavated pit with alternate layers of salt, charcoal around the coil with a diameter of 300mm upto 1000mm and balance by good quality soil, end termination complete as required.
498FIRE FIGHTING & FIRE ALARM SYSTEM
499Sub-Head - I - DOWNCOMER.
500Supply, erection, testing and commissioning of following sizes of heavy grade ("C" class) mild steel pipe, flanges and fitting such as bends, tees, reducers, rubber insertions and galvanized nuts and bolts"Heavy class" confirming to IS:1239-1974 Part - I and part - II with upto-date amendment i/c giving two coats of hot bituminous paint. Make- Tata/Zindal/Sail/Eq
501100mm dia
50280mm dia
50325mm dia
504Providing and fixing Single headed, S.S ISI marked oblique patternhydrant landing valvewith80mmdia flangedinlet and 63mm dia instantaneous type female outlet complete withcap and G.I. chain, twist release type plug and all accessories as per 13:5290-1983 (Type "A"). Make-KARTAR, Safex, Fireshield,Safe Guard
505Providing and fixing standard short size gunmetal branch pipe with gunmetal nozzle 16mm dia outlet with standard male instantaneous spring lock type 63mm dia coupling.Branch pipe and nozzle shall confirm to IS : 903-1985. Make-KARTAR, Safex, Fireshield,Safe Guard
506Providing and fixing Non-percolatingflexible canvas hose(RRL type-"A") ISI marked (IS:636) 63 mm dia x 15 M long complete with instantaneoustype gunmetal 63mmdia. IS markedMaleandfemale couplings (IS:903)bound and riveted to hose pipe with copper rivets and 1.5 mm copper wire. Make-KARTAR, Safex, Fireshield,Safe Guard
507Providing and fixing standard fireman"s axe with heavy insulated rubber handle complete.
508Providing and fixing dial type pressure gauge with isolation cock and pipe. Make-H.guru/Emerald/Fiebig/Equivalent
509Dial diameter 100mm calibration 0-15 kg.
510Providing and fixing first aid fire hose reel equipment confirming to IS : 884-1969 with upto date amendments finished with post office red spray paint and complete with following as required :Make-KARTAR, Safex, Fireshield,Safe Guard
51120mm dia 30metres long hose tubing of approved make confirming to IS : 5132-1969 with upto date amendments.
512Swinging type hose guide fixing bracket assembly
5136mm outlet gunmetal nozzle with shut off valve as required
514Providing and fixing brass/bronze lever operated ball valves of full flow with stainless steel ball (AISI 304 and spindle AISI 401) with settling and gland of superior quality and having minimum working pressure of 15 Kg/cm2.Make-Kartar/Zoloto/H Sarker/Eq.
51525NB
516Supply, installation, testing and commissioningof Fire Brigade inlet connection with provision for Four male instantaneous coupling fabricated out of 150 mm dia. approved make heavy class MS pipe with non-return valve, Butterfly valvefor fire fighting system including making connection by providing necessary piping & fittings to the fire storage tank, fire fighting wet riser, sprinkler system painting the same with 3 coats of enamel paint over a coat of Zinc Chromate primer all complete as per drawings, specifications. Make-Minimax, Safex, Fireshield,Kartar.
517a) Three way
518Sub-Head II- Terrace Pump
519Supplying,installation,testingandcommissioningof electric driven terrace pump suitable forautomatic operationandconsistingoffollowing,completeinall respects, as required: (Terrace Pump). Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520. SuitableHPsquirellcageinductionmotorTEFCtype suitable for operation on 415 volts, 3 phase, 50 Hz, AC supplywithIP55classofprotectionforenclosure, horiziontalfootmountedtypewithClass-"F"insulation,conforming to IS-325. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. Suitablecementconcretefoundationdulyplastered and with anti vibration pads. Make-wilo,kirloskar/lubi/equivalent.
520900 lpm at 35 m Head
521Sitcof Terrace Pump Controller
522Supplying,installation,testingandcommissioningof pump controller.Make-c&s/l&t/crompton/Eq
523Sub-Head IIIFIRE PUMPS & ANCILLARY WORKS
524Providing,installation,testingandcommissioningof cast ironY-strainerfabricatedoutof1.6mm thickstainlesssteel,Grade304,sheetwith3mmdia holes with stainless steel flange.Make-Kartar/Zoloto/H Sarker/Eq.
525100mm dia
526Providing, fixing, testing & commissioning ofC.I. dual plated Non-return valve [PN 1.6 Rating (16kg/cm2] complete2 nos. matching flanges, rubber insertion, with nuts, bolts and washers etc of following sizes .Make-Kartar/Zoloto/H Sarker/Eq.
527100 mm dia
528Providing, fixing, testing & commissioning of C.I. Butterfly valve conforming to IS : 13095 with nut, bolts and washers complete . [PN -1.6 rating (16kg/cm2)]Make-Kartar/Zoloto/H Sarker/Eq.
529100NB
530Supply,Providing & fixing Pressure Switchthe most commonly used fluid control components of Aluminum enclouser with storage temprature 40 to 180°F (-40 to 82°C) along with ambienttemprature 0 to 160°F (-18 to 71°C),set point shifts less than 1% of range for a 50°F (28°C) ambient temperature change. Unit will operate down to -40°F (-40°C) but with reduced repeatability. Maximum media temperature 200°F (93°C), Shock Set point repeats after 50 G, 10 millisecond duration. Switch output One SPDT including seven electrical terminations; Refer to "How to Order" and vibration set point repeats after 10 G, 5-500 CPS.Make-Honeywell/Danfoss/Jhonson controls.
531Sub-Head - IV -Hand Appliances
532Note :All the fire extinguishers shall be ISI marked and filling/validity date shall be painted.
533Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2878 finished externally with red enamel paint and fixed towall with brackets complete with internal charge.Make-Minimax, Safex, Fireshield, Safe Guard
534Capacity 4.5 kg
535Providing and fixing ABC type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS finished externally with red enamel paint and fixed towall with brackets complete with internal charge. Make-Minimax, Safex, Fireshield, Safe Guard
536Capacity 6 kg
537Supplying and installing at approved location approved make fire buckets at 24 gauge galvanized stseel sheet, standard 9 liters capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter "FIRE" in black and gold.Cost shall be inclusive of Providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 5 buckets. Make-Agni,/Cease fire/Eq.
538Sub-Head V FIRE DOOR
539Supply, installation, testing and commissioning offire metal door. Pressed Galvanized steel confirming to IS 277 specification.Door frame shall be Double rebate profile of size 139 x 57 mm made out of 1.20mm minimum thick galvanized steel sheet& single leaf door. Provision should be kept for grouting with cement & sand slurry necessary for fire doors on the clear masonry opening. Door leaf should be 43mm thick fully flush double skin door. Door leaf shall be manufactured from 1.0 mmthick galvanised steel sheet single leaf door. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepared for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. painting system will be powder coating finished. Make: Coburn /Garg or Equivalent
540Size : 1250mm x 2250mm(single leaf )
541Sub-Head VI EXIT SIGNAGES
542supplying,fixing of following type 2 mm thick photo luminecent signages non toxic non radio active maintenance free self glowing safety signages comprising of supplied chargeable crystals to glow in the dark with high intesity luminous 1.2mm aluminium sheet properties by chemical coated ( Vinayal & Tap not accepted) and covered with UV Protection layer printed with graphics symbol etc as required.
543For FIRE EXIT(12"" X 6"")
544For FIRE HYDRANT(16"" X 6"")
545For Lift (12"" X 6"")
546For Stair case (12""x6"")
547Arrows symbol(12""x6"")
548Sub-Head VII FIRE ALARM SYSTEM
549SITC ofMicroprocessor based,Conventional type Fire Alarm Control Panel with 2 nos. of zone.operating voltage 24v dc. Make: Honey well / Agni/ Esser/Eq
550Hooter with Strobe Supply, installation, connecting, testing and commissioning of Conventional Hooters cum strobe min. 95 db output , the cost includes of control module .Make: Honey well / Agni/ Esser/Eq
551Supply, installation, connecting, testing and commissioning of  Conventional Manual Call Box in ABS plastic  as required complete Pull Down Type. Make: Honey well / Agni/ Esser/Eq
552Looping Cable Supplying, installing, testing and commissioning of Fire Survival armoured cable,Fibre glass tape wrapped, ZH inner, outer sheath 2C X 1.5 sq. mm, PVC insulated copper wires with aluminium armour confirming to IS standards and specifications. Make-Polycab/RR cable/Eq
553HVAC
554Supplyinstalation testing commissioning of HI-WALL TYPE UNIT with OEM manufactured rotary compressor Three Star rated non inverter type with stablizer (R410A/R32- refrigerant)suitable for 230V, 50 Hz, single phase AC. ) & making all arangement for installation i/c factory fabricated bracket, cutting the wall, making good the damages etc. as required(Make:- Daikin ,Hitachi or Eqiv) & making all arangement for installation i/c factory fabricated bracket, cutting the wall, making good the damages etc. as required.with Refrigerant Copper Piping Make-Rajco/Mandev/Maxflow ,PVC drain piping including insulation Kinni foam connectionswithunitswithU-trap, nipple clamps etc. of make-Ashirbad/Astral/Supreme
5552 TR
556MECHANICAL VENTILATION
557Supply installation, testing , commissioning of SISW Backward curved centrifugal fans (Bearing, motor and shaft shuould be outside of airflow path).Consistng of motor , drive arrangement, MS channel common base frame for fan. Fan should be AMCA certified for AIR, SOUND and FEG( minimum FEG should be 80). Outlet velocity of the fan should not exceed 11 m/s. Shound level of the fan should not exceed 75db(A) @ 3 meter distance. Installed motor Kw. should be 30% higher than fan brake Kw. (Moter make- Havels/ CGL/ BBL/ Hindustan Motors). ( Fan Make-kruger, Nicotra, Greenheck)
5583900 CFM @25mm static pressure
5592700 CFM @25mm static pressure
560Supply, installation, balancing and commissioning of Site fabricated Gi sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as per specifications.(As per SMACNA)(Make-TATA, SAIL,Jindal)
56124 Gauge ( Thickness 0.63mm)
562Supply, Installation, testing and balancing of powder coated Alluminium Grilles complete withnuts, bolts, screws etc. as per drawings and specifications. (Make-Glenstroms, carryaire,System air )
563Supply air grille withAlluminium volume control damper
564Supply, fixing and commissioning of exhaust air louvers with section comprising of powder coated Aluminium louvers & bird screen as per specifications. (Make-Glenstroms, carryaire,System air )
565ELECTRICAL WORKS
566Supply, laying, testing and commissioning of following sizes of PVC sheathedXLPEinsulatedAluminiumconductorarmouredcablesof 1100Vgradeonsurfaceofwallorinexistingcabletrays/masonry ducts/ hume pipe with fixing hardware etc. as required. (Make- Polycab, Havels,RR cable )
5674 Core x 2.5 Sq.mm
568STARTER PANEL FOR FAN
569Supply, Installation, testing & commisioning of 3 KW 3 phase DOL starer with D range Contactor & LR1D OLR in 2mm CRCA steel sheet duly painted having 1 no 32A 4P MCB, 1 no 3P power contactor, 1 no 9 to 15A PLR, 1 no 30A CT operated ameter, 3 nos. phase indication lamp, 3 nos. ON,OFF,TRIP indicator, 2 nos. ON/OFF push button, 1 no. emergency stop with provision for remote operation for ventilation fan. (Make- L & T, Siemens, Havels)
570CCTV
571SUPPLY AND INSTALLATION 64 CH NVR Up to 12 MP resolution 8 SATA (DS-8664NI-I8 ) Make: HIKVISION or equivalent.
572SUPPLY AND INSTALLATION 32 CH NVR Up to 12 MP resolution 2 SATA (DS-7632NI-K2 ) Make: HIKVISION or equivalent.
573SUPPLY AND INSTALLATION 16 CH NVR Up to 12 MP resolution 2 SATA (DS-7616NI-K2 ) Make: HIKVISION or equivalent.
574SUPPLY AND INSTALLATION 2MP DOME CAMERA (DS-2CD1323G0E-I) Make: HIKVISION or equivalent.
575SUPPLY AND INSTALLATION 2MP BULLET CAMERA (DS-2CD1023G0E-I) Make: HIKVISION or equivalent.
576SUPPLY AND INSTALLATION 16 PORT GIGA POEMake: HIKVISION or equivalent.
577SUPPLY AND INSTALLATION 8+1 PORT GIGA POEMake: HIKVISION or equivalent.
578SUPPLY AND INSTALLATION 4 TB HDD Make: SEAGATE or equivalent.
579SUPPLY AND INSTALLATION 2U RACK WITH FANE PDU Make: NETRACK or equivalent.
580SUPPLY AND INSTALLATION 9U RACK WITH FANE PDU
581SUPPLY AND INSTALLATION UTP 4P CAT 6CABLE(As Per Actual) Make: D-LINK or equivalent.
582SUPPLY AND INSTALLATION UTP 4P CAT 6CABLE(As Per Actual)
583ELEVATOR
584“Testing, Supply, Delivery, Installation & Commissioning with approved materials, labour etc. in all respect complete of02 nos. Passenger Lift from (GF to 5th Floor), 01 no. Passenger cum Stretcher Lift from (GF to 5th Floor),as detailed in specifications and complete in all respect for NEW HOSTEL & MUB BUILDING AT Koraput MEDICAL COLLEGE CAMPUS
585Providing Passenger Lift ,
586Supplying, installation, testing and commissioning of 10 passenger (680Kg) lifts having contract speed of 1.25 MPS serving different floors in the lift shaft including 12 months maintenance period as per detailed specifications enclosed (Annexure) and Terms & Conditions mentioned in NIT and as under :- Location – Girls Hostel , Koraput , Odisha. Type – Gear less machine with Machine Room Speed – 1.25 MPS Floors - 6 floors (G+5 floors) Travel – 16.5 meters (approx.) Stops & Opening – 6 Nos at the same side Controller – microprocessor controlled electronically regulated A.C. variable voltage & variable frequency (VVVF) drive using pulse width modulation (PWM) with phase reverse relay. Automatic Rescue Device complete with dry maintenance free battery of maximum 12 AH capacity each with required Nos. Operation : Microprocessor based single automatic push button with Simplex collective selective /without attendant. Power - 415 Volts, 3 phase, 50 Hz, 4 wires system A.C. Type of Doors- Horizontal Sliding – Centre Opening
587Car – 800mm clear opening with power operated fully automatic centre opening horizontal sliding, Stainless steel scratch proof 1.5 mm thick moon rock finish body work stainless steel drop ceiling and CFL/ LED lamps for lighting inside the car and fan. PVC 3mm thick (minimum) flooring. Landing Doors- Automatic and multi beam full height infra red detector automatic centre opening horizontal sliding 1.5 mm thick stain less steel scratch proof moon rock finish. Fire rating -120 min. Stainless steel hand rail not less 600 mm long at 900mm above floor level to be fixed. Brail system including all facilities for physically challenged persons. Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the elevator, complete with Automatic operated control panel and signals, lift car, car safety devices as per IS: 14665, and as per attached detailed specifications and additional conditions i/c provision for temporary scaffoldings and all minor building works
588Original manufacturer among the approved makes i.e. JOHNSON/OTIS/KONE/SCHINDLER/MITSUBISHI/eq make
589Supplying, installation, testing and commissioning of 15 passenger-cum-stretcher (1020Kg) lifts having contract speed of 1.25 MPS serving different floors in the lift shaft including 12 months maintenance period as per detailed specifications enclosed (Annexure) and Terms & Conditions mentioned in NIT and as under :- Location – Girls Hostel , Koraput , Odisha. Type – Gear less machine with Machine Room Speed – 1.25 MPS Floors - 6 floors (G+5 floors) Travel – 16.5 meters (approx.) Stops & Opening – 6 Nos at the same side. Controller – microprocessor controlled electronically regulated A.C. variable voltage & variable frequency (VVVF) drive using pulse width modulation (PWM) with phase reverse relay. Automatic Rescue Device complete with dry maintenance free battery of maximum 12 AH capacity each with required Nos. Operation : Microprocessor based single automatic push button with Simplex collective selective /without attendant. Power - 415 Volts, 3 phase, 50 Hz, 4 wires system A.C. Type of Doors- Horizontal Sliding – Centre Opening
590Car – 900mm clear opening with power operated fully automatic centre opening horizontal sliding, Stainless steel scratch proof 1.5 mm thick moon rock finish body work stainless steel drop ceiling and CFL/ LED lamps for lighting inside the car and fan. PVC 3mm thick (minimum) flooring. Landing Doors- Automatic and multi beam full height infra red detector automatic centre opening horizontal sliding 1.5 mm thick stain less steel scratch proof moon rock finish. Fire rating -120 min. Stainless steel hand rail not less 600 mm long at 900mm above floor level to be fixed. Brail system including all facilities for physically challenged persons. Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the elevator, complete with Automatic operated control panel and signals, lift car, car safety devices as per IS: 14665, and as per attached detailed specifications and additional conditions i/c provision for temporary scaffoldings and all minor building works.
591Original manufacturer among the approved makes i.e. JOHNSON/OTIS/KONE/SCHINDLER/MITSUBISHI/eq make
592P.H. WORK Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor C-PVC pipesconforming topipe fittings of the following nominal bore with clamps including making good the wall, ceilingand floor all complete as per specification and direction of the Engineer in charge
593GroundFloor
59420mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
59525mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
59632mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
59740mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
59850mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
599In 1st Floor
60020mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
60125mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
60232mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
60340mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
60450mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
605In 2nd Floor
60620mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
60725mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
60832mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
60940mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
61050mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
611In 3rd Floor
61220mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
61325mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
61432mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
61540mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
61650mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
617In 4th Floor
61820mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
61925mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
62032mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
62140mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
62250mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
623In 5th Floor
62420mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
62525mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
62632mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
62740mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
62850mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
629In 6th Floor
63040mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
63150mm dia C-PVC pipe (Ashirbad/Supreme/Truflow)
632Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.
633250mmthick wall in Ground floor
634In 1st Floor
635In 2nd Floor
636In 3rd Floor
637In 4th Floor
638In 5th Floor
639Supplying all materials, labour, T&Pand cutting hole in R.C.C floors, roofs, etc upto 19 cm thickfor passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes afterinsertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of theEngineer in charge. in Ground Floor
640In 1st Floor
641In 2nd Floor
642In 3rd Floor
643In 4th Floor
644In 5th Floor
645Supplying allmaterials, labour, T&P and cutting grooves in pucca floors and walls for takingGI/ PVC pipes and making good the damages as per the direction of the Engineer in charge. In Ground Floor
646In 1st Floor
647In 2ndfloor
648In 3rd Floor
649In 4th Floor
650In 5th Floor
651Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all completeas per PH specification and direction of the Engineer in charge
652250mm to 375mmthick wall
653in Ground Floor to 5th Floor
654Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge
65515mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make)
65615mm dia CP angle stop cock (Con-CHR-053KN Jaquar make)
65715mm dia CPBib cock (Con-CHR-047KN Jaquar make)
65820mm dia CP consealed stop cock(Con-CHR-083KN Jaquar make)
65915mm dia CP two in one bib cock (Con-CHR-041KN Jaquar make)
66015mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make)
66115mm dia CP extension piece
66215mm dia CP Pillar cock (Con-CHR-011KN Jaquar make)
66325mm dia G.M or Brass F.W valve (Sakti make)
66440mm dia G.M or Brass F.W valve (Sakti make)
665125mm dia CP gratings
66615mm CP revolving shower (Jaquar)CON-CHR-209KN
66750mm dia G.M or Brass F.W valve (Sakti make)
668Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricantby non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge
669110mm dia U-PVC SWR pipes(Supreme/Ashirvad)
670110mm U-PVC door bend
671110mm U-PVC door Tee
672110mm U-PVC plain Tee
673110mm U-PVC plain Y
674110mm dia U-PVC offset without ear
675110mm U-PVC plain bend
676110mm U-PVC vent cowl
677110mm dia U-PVC "P" trap
678110mm dia suitable PVC clamp
679Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge
68010 litres PVC L.L. Cistern (Slimline-white)
681Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan conforming to IS:2556-part-3-2004) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x 30mm footrest, fixing 100mm dia HCI ‘P’ or ‘S’ trap (with/without 50mm dia horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge(Nycer,parryware make)
682580mm size Orissa pan(Hindware/Parryware/Jauar)
683Supplying all materials, labour, T&P and fixing glazed earthenware squatting plate of size 600mmx350mm with integral longitudinal flushing pipe including embedding the plate in 25mm cement mortar (1:8) laid over 150mm cement concrete (1:5:10) using 40mm hard granite metal all complete as per specification and direction of the Engineer in charge
684Fixing of squatting urinal (Parryware/Hindware/Jauar)
685Supplying all materials, labour, T&P and fixing Wash Down Water Closet (European type W.C pan) with integral ‘S’ or ‘P’ trap to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification and direction of the Engineer in charge.
686E.W.C. with seat cover (Parryware/Hindware/Jauar)
687EWC(Matrix set)No.70002(P-18)
688Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make),etc all complete as per specification and direction of the Engineer in charge
689550mm x 400mm size W. H. Basin with Porcelain Pedestal (Parryware/Hindware/Jauar)
690Under Counterbasin(560x450)Hindware-No.10095
691Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge
692600mm x 450mm size B.E mirror
693Large size mirror with frame(75x0.60x0.90)=40.50
694Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge
695600 x 125mm plate glass shelf with CP guard rails(Jaquar)AKP-CHR-35771P
696Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge
69725mm x 600mm long CP towel rail(Jaquar)ACN-ACR-1111N
698CP towel Ring(Jaquar)ACN-ACR-1121N
699Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge
700CP soap holder (Jaquar)ACN-ACR-1131N
701Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste, fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge
702600 x 450 x 250mm size S/S kitchen sink (Jayana make )
703Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard granite chips broken including watering, curing, conveyance of all materials to worksite, payment of royality, taxes etc all complete as aper specification and direction of the E.I.C In 1st Floor
704In 2nd Floor
705In 3rd Floor
706In 4th. Floor
707In 5th. Floor
708Supplying all materials, labour, T&P and providing cement flush pointing with C.M (1:3) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
709In Ist Floor
710In 2nd Floor
711In 3rd Floor
712In 4th Floor
713In 5th Floor
714Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including cement punning,watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
715In Ist Floor
716In 2nd Floor
717In 3rd Floor
718In 4th Floor
719In 5th Floor
720Supplying the waterproofing material Pidifin 2K of Dr.fixit on equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1"-6" in wall including cleaning,applying and mending as per specification including all labour charges as per direction of Engineer-in-charge.
721In Ist Floor
722In 2nd Floor
723In 3rd Floor
724In 4th Floor
725In 5th Floor
726Supplying all materials, labour, T&P and providing and filling cynder including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
727In Ist Floor
728In 2nd Floor
729In 3rd Floor
730In 4th. Floor
731In 5th. Floor
732Supplying all materials, labour, T&P and providing Ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles etc complete as per direction of the Engineer in charge. (vitrified tiles of size300x300 of make- Kajaria/Somany/Johnson/Orient Bell/Rakplain/printed series to be pre-approved by the Engineer in charge)In 1st Floor (Kajaria-Fogparla or equivalent make)
733In 2nd Floor
734In 3rd Floor
735In 4th Floor
736In 5th Floor
737Supplying all materials, labaour, T&P and fixing ceramicglazed tiles in dados skirting on 12mm thick cement plaster (1:3) joined with neat cement slurry mixed ith pigments to match the shades of the tiles etc. complete as per direction of the Engineer-in-charge.(ceramic vitrified Glazed tiles in wall of size 450x300 ) of makeKajaria/Somany/Johnson/Orient Bell/Rak) plain/printed series to be pre-approved by the Engineer-in-charge. in Ground Floor(Kajaria-Durenmarfil or equivalent make)
738In Ist Floor
739In 2nd Floor
740In 3rd Floor
741In 4th Floor
742In 5th Floor
743Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finishstructural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material,The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre"s standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter.
744Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigmentscomplete in all respect as per specification and direction of the Engineer in charge
745Finishing wall surface of walls with providing two coats wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc complete.
746In Ist Floor
747In 2nd Floor
748In 3rd Floor
749In 4th Floor
750In 5th Floor
751Supplying all materials, labour, T&P and distempering two coats to walls with distemper of approved shade on new work to give an even shade etc all complete as per specification and direction of the Engineer in charge
752In Ist Floor
753In 2nd Floor
754In 3rd Floor
755In 4th Floor
756In 5th Floor
757Supplying all materials, labour, T&P and constructing Gully Trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, Fly ash brickwork in c.m (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat ofneat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size C.I grating etc all complete as per approved drawing, specification and direction of the Engineer in charge
758Supplying all materials, labour, T&P and constructing Inspection Chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6),moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge
759Inside size 760mm x 760mm x 460mm
760Fitting and fixing RCPC cover slab (0.45m dia)
761Supplying all materials, labour, T&P and providing kodappa slab in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge
762Supplying all materials, labour, T&P and providing granite tiles in slab, treads and landing on 20mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles etc all complete as per direction of the Engineer in charge
763Construction of 40000 Liters RCC Over head Tankin sixth floor with RCC Stagging(Domestic & Fire fighting)
764Supplying all materials, labour,T&P and providing cement concrete (1:1.5:3) for RCC work using 12mm HG chips including hoisting,laying,curring and conveyance of all materials to site etc complete.
765Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gauge.in 6th Floor.
766Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in 6th Floor.
767RCC floor roof, chajja etc
768RCC Beam, Column, wall etc
769Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) overCC workincluding watering curring and conveyance of all materialsto site.
770Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site.
771Providing fitting and fixing stainless steel ladder including fixing to wall necessary welding etc. complete
772Providing fitting and fixing MS cover made out of MS angle and sheet duly welding and fixing with frame and hinges along with locking arrangement of size 60cmx60cm etc complete as per direction of Engineer-in-charge
773Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS UV of size 750x570x1350mm height with water storage capacity 120 liters along with 3 nos of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all completeas per approved drawing,specification and direction of the Engineer in charge.
774Aquagurd Pure Chill 120 PSS UV
775Sinking of 200mmx150mm dia Bore Well through DTH method.- 2 Nos.
776Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation(G.I/P.V.C/M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only
777Drilling of 200mm dia bore0 to 30 mtr
778Drilling of 200mm dia bore31 to 45 mtr
779Drilling of 150mm dia bore41 to 125 mtr
780Labour for lowering the following size of PVC casing pipes with or without slotted pipes as per necessity from ground level upto 300 mtrs depth and fitted and set up in perfectly vertical position including cutting and threading of blank pipes and slotted pipes and supplyinging and fixing of all jointing materials ,extra sockets and T&P etc. all complete and keeping the top of casing pipe threaded including plugging the tubewell to prevent entry of foreign materials
781Lowering of 200mm dia PVC casing pipes 0 mtr to 30 mtrs
782Lowering of 200mm dia PVC casing pipes 31 mtr to 45 mtrs
783Cost of 200mm dia PVC schedule - 80 pipe
784Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge
785Supplying all materials,labour,T&P andproviding around sealing by cement concrete grouting of annualr space around GI/PVC housing pipe upto 5 mtr below ground level ( as per drawing ) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer-in-charge . Mimimum one meter of casing pipe to nserted in the bore in to the rock the bottom to ensure sanitary sealing ( excluding cost of cement which willbe supplied by the Department )
786Sanitary sealing upto 5 mtr below ground level
787CC(1:2:4) with 12mm chips for grouting up to 5 mtr Depth in
7881x5x3.14x(0.15-0.10)
789Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing,commissioning,trial running,conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge.
7902HP Three Phase 3 stage submersible pump set.
791DOL control panel
79250mm S. S. Nipple, S. S. bolt & clips
79350mm M. S. Clamp, Bend, Socket & 200mm M. S. well cap
7942.50mm Sqm Submersible flat cable
795Steel rope with cover
79620mm dia rigid U-PVC pipe
79750mm dia HDPE pipe
798Labour charges for lowering, testing, commissioning & transportation to site etc.
799Supply all materials, labour, T&P and providing, fitting and fixing of centrifugal pump set to run on 3phase/1phase line voltage ranging from 320 volt to 450 volt with suitable control pannel, jointing with GI/ PVC/ HDPE pipes electrification, testing,commissioning,trial running,conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge.
8005 HP 3 phaseHorizontal submerssiblepump set.
801DOL control panel
802Labour charges for lowering, testing, commissioning & transportation to site etc.
803Supplying all materials, labour, T&P and providing and laying in trenches PVC ASTM pipeof the following nominal bore, tube fittings, testing all complete as per specification and direction of the Engineer in charge
80450mm dia PVC ASTM
805Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor CPVC pipesof the following nominal bore and pipe fittings with clamps including making good the wall and testing as per specification and direction of the Engineer in charge
80650mm dia CPVCpipe (sch-80)
807Earth work in all kinds of soil within 50 mtr initial lead and 1.5mtr initial lift includingrough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3 mtr in depth and as per direction of the Engineer in charge.
808100m x 0.45m x 0.60m =27.00
809Supplying all materials, labour T&P and fitting and fixing brass/CP/PVC fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer in charge.
81050mm dia Brass N. R. Valve
81150mm dia Brass Check Valve
81250mm dia Brass F. W. Valve
813Supplying all materials, labour, T&P and construction of Fullway valve chamber/Stop cock chamber of the following inside size for fullway valve with cement concrete slab (1:2:4) mix , 7.50cm thick, foundation concrete (1:5:10) and inside plastering with cement mortar (1:3) finished with a floating coat of neat cement including curing etc all complete as per approved specification and direction of the Engineer in charge
814Inside size 250mm x 250mm x 560mm
815Supplying all materials, labour, T&P and constructionman hole chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1½:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge
816Inside size 910mm x 910mm x 910mm
817Addl depth
818Fitting and fixing RCPC cover slab (0.45m dia)
819Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class K.B brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge
8201.40m dia x 2.00m deep
821Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasingincluding concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.
822110mm dia u-pvc pipe alround concrete
823160mm dia u-pvc pipe alround concrete
824200mm dia u-pvc pipe alround concrete
825Supplying all materials, labour, T&P and constructing circular type man hole chamber of the following sizewith cement concrete (1:4:8) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar (1:5), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, 12mm thick cement plaster (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge
826Circular MH inside dia 1200mmx1670mm with sides sloped upto560mm
827Cost of RCPC Cover
828Construction of 50 KLDSTP Civil Works
829Earth work in excavation of foundation in all kinds of soil within 50 mtr initial lead and 1.5mtr initial lift includingrough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3 mtr in depth and as per direction of the Engineer in charge.
830-do- with Ist additional depth of 1.50 m over the initial lead and lift
831Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer incharge.
832Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
833Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
834R.C.C. work of M-30 grade with 20mm and down grade black hard black crusher broken granite stone chips of approved quality from approved quarry including hoisting, lowering, laying and compacting concrete, watering curing, centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,labour cess and T & P required for the work etc. complete in all respect but excluding the cost and conveyance of M.S. rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position and as per spection and the direction of the Engineer-in-charge.
835Base slab
836Wall
837Roof Slab
838RCC Lintle
839Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage.
840Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) overCC workincluding watering curring and conveyance of all materialsto site.
841Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site.
842Quantity same as itemabove inside
843Supplying and fitting and fixing stainless steel 304 grade in said rail using 5mm dia 2mm thick circular pipe and balustrade 32mmx32mmx2mm at the rate of mtr.Center to center and square pipe 32x32x2mm below doors and windows with ss platevincluding welding with stanless steel elect rod and fixing with necessary accessories etc.complete as per direction of the Engineer-in-charge.
844Providing fitting and fixing RCPCcoveretc complete as per direction of Engineer-in-charge
845Supplying all materials, labour, T&P and providing brick work using fly ash bricks in CM(1:6) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
846Supplying all materials, labour, T&P and providing 16mm thick cement plaster in CM(1:6) over brick work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
847Supplying all materials, labour, T&P and providing 12mm thick cement plaster in CM(1:4) over brick work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
848Supplying all materials, labour, T&P and providing two coats of plastic paint over a coat of primer of approved shade, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
849Quantity same as itemabove inside
850Supplying all materials, labour, T&P and providing two coats of weather coat over a coat of primer of approved shade, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
851Quantity same as itemabove 231
852Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, all materials, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge.
853Quantity same as itemabove inside
854Electro Mechanical portion of 50 KLD STP
855Supplying, Installation, testing & commissiongof Packeged type Prefabricated (MS with 3mmFRP coating with anti-corrosivecoating Modular STP Capacity of 50 KLD on FMR (Fludised Media Reactor) / FAB (Fludised Aerobic BioReactor) technology with Lamella/Tube Settler andproviding all equipment, piping etc.at site including erection testing & commisioning of equipments, electricals, piping for Sewage Treatment Plant (Make - ION Exchange (India) Ltd.)
856The RawSewage shall be domestic Sewage and the qualityof treated sawage shall be as under: BOD : Shall not be more than COD : Shall not be more than TSS : Shall not be more than Oil and grease : Shall not be more than 10 mg/litre The STP shall be covered following
857MS bar Screen : Supplying , installing , testing and commissioning of 1No.barscreenintheexistingcivilstructureinfrontoftheintake works , so as to exclude the large sized particleswith associated set ofguide anglesinMSflatof10.00mmscreenkeptinclinedat45 degreetothehorizontalat40mmc/cwithoneno.handrackinGI. (Necessarycorrection/modificationrequiredtobedoneinexisting civilstructureshallbedonebythecontractorathisowncost).Bar rackshallbefabricatedfromSS-304barstocoverthewidthofthe screen chamber with a racking arm for manual operation. Size: 10 mm
858RawSewagePumps: Supplying, installing, testing and commissioning of 02 Nos (1W + 1S) centrifugal, Non - Submersible type raw sewage water pumps with a solid handling capacity of 40 mm to pump sewage from equalisationsumptoaerationtankatuniformflowrate.Thepump shall be three phase, three HP electrical motor mounted on a common base frame each of these pumps shell also include. (Make : Jhonson / Kriloskar / equi. )
859a). Dry run protection. b) 1 No.Pressure gauge 4" dial with valve tee and fittings. c) 2nos.castironleveropertedslimsealtypebutterfly valvesofCI bodyandspheroidalgraphiteirondisc(SGiron),withnitrilerubber seal , tested to 10 kg / sq. cm Confrming to BS 5155 / MF6 standards andincludingasetofGIflangesasper BS-10table1includingbolt nuts,GIwashers,andneoprenerubbergasketsCompleteetc.( Make: Crane / Intervalve / Audco ) on the delivery side.
860d) 2Nos. Slimsealflap typecheck valvewith CI body andcast steel disc pressure rating PN-10 kg/ sq. cm including a set of GI flanges as perBS-10table1includingboltnuts,GIwashers,andneoprene rubbergasketscompleteetc., (Make: Expert / Intervalve / Audco )onthe delivery side. e) GI manifold finished neatly with hot dip galvanizing to 100 microns withflangedendoneithersidesandcollarprovisionforconnectivity of above mentioned valves. Thesepumpsshallbesuitableforthefollowingrequirements:Flow rate = 2.5 cum/hr., Head 10 meter.
861PRE-FABRICATED STP
862a) SEWAGE TREATMENT PLANT (STP) - MS TANK with 3mmthick FRPcoating inside with Akzo Noblecoatingonbothsides ofSewagetreatmentplant, having an inbuilt Aeration-I& Aeration-II,Lamella/Tubesettlingtank,chlorinecontacttankwith laddersprovisiononeachplantandrailingetc.,havingmin.sizeof (L x B x H)4.0mx 2.13 mx2.2m,minimunvolumeofreactor should be19CuMtr.orasperapprovedOEM"sdesignandcapacitybut shouldhaveminimumretentiontimeof6hours,Minimumthickness of MS sheet should be 5 mm with special anti corrosive coating.
863Following shall also be provided in Sewage Treatment Plant.
864b) Air Diffusuion system forSTP aeration chamer I&II:Supplying installing,testingandcommissioningof06Nos.airdiffusersof varyingsizesconsistingoffinebubblediffuser alongwithmembrane fromEDI, USAshallconsistsofsetofEPDMmembranes,SS304 clips,PVC support pipe(10kscpressure rating),PVCfitting,nylon ropebraidedhosewithallaccessoriestomakeitretrievable&to provide cloq- free oxigen for Aeration tanks.
865c) MBBR ( Moving Bed Bio Film Reactor) / FMR ( Fluidized Media Reactor) Media : Supplying, installing, testing and commissioning of 1.5 cum MBBR/FMR Media.
866d)LAMELLACLARIFIERMECHANISM : Supplying, installing, testing and commissioning of one set of lamella/tube settler clarifier mechanism to fit into clarifier tank which consists of inclined overlapping FRP plates which will be arranged to form a separate dimentation chamber or the cells between each pair of adjacent plates. The overlapping additive projected area of several plates will be a factor of increasing surface settling area proportion to the number of plates used.
867The inlet flow will divide and enter the tower part of each sedimentation cell from its two opposite sides. As the water will displace upward in smooth, gently, flow, the suspended solids coalesce to from precipitates which will settle in the chambers on the lower portion of each lamella plate. Influent water flows upwards over the plates. The deposited precipitates increase in size until they slide or roll down the inclined surface of the plates. This will then be collected in the hopper provided at the bottom of the separator.
868Air Diffusion System for EQ ( Equalization ) tank& SHT( Sludge HoldingTank) : Supplying, installingandcommisioning of Air Grid of varying sizes as per manufacurers specifications with PVC flexible hose HDPE pipegrid (or) as per OEM manufacturers design to provide clog - free oxygen for Equalisation Tank & Sludge Holding Tank.
869AirBlowers:Supplying, installing, testing and commissioning of TwinLobe designtype02 Nos (1W + 1S)airblowercompletewithmotors, pulleys,RigidonepieceCIcasingandsideplates,silencer,base plate,anti-frictionbearings,Rotaryoilsealingshavinghorizontal configuration
870a)TwinLoberoot typeAir blower of75 m3/hrat 0.37kg/sqcm capacitycomprisingofcommonbaseframe,suctionsilencer,non, return,Vbelt,safetyvalve,beltguard,driveanddrivenpulleys, pressuregauge,interconnectionpiping, dischargesilencer,anti vibration pads including required motor of 3.0 HP, 1500 rpm, IE-2 efficiency with IP-55 protection
871b) 2 Nos. cast iron lever operated slim seal type butterfly valves of CI bodyandspheroidalgraphiteirondisc(SGiron),withnitrilerubber seal,testedto10kg/sq.cmconformingtoBS5155/MF6standards andincludingasetofGIflangesasper BS-10table1includingbolt nuts, GI washers, and neoprene rubber gaskets complete etc. ( Make: Crane / Intervalve / Audco / Kitz / Zoloto / equivalent )on the delivery side.
872c) 1 No. pressure gauge 4"dial with valve tee and fittings.
873ChlorineDoser:Supplying, installation, testingand commissioning of on line electronic sodium hypo dosing unit with automatically operated dosing pump, etc., Theunitshallcompriseof the following.
874One No. Single moulded FRP cylindrical type chemicalsolution tank of 100 litres capacity having detachablelidswith moulded inserts for mounting of pumps and starter.
875OneNo.Electronicdiaphragmtypepositivedisplacementpump,for chemicaldosingwithplastic head.Theelectronicpumpshallbe operatedon220Vsinglephasesupply andshallbemounteddirecty on the tank top. ( Make: Milton Roy / Asia LMI )
876Completesetofpipes,valvesandfittings,footvalvemagneticfloat switch to trip the dosing pump at low level of chemical in the tank.
877Thefreechlorinecontentinthefilteredwatershallnotbelessthan 0.5 PPM.Shall consists of one no. 100 Ltrs., HDPE / LLDPE tank with one no. PP, diaphragm type pump of capacity: 0 - 4 LPH shall be provided.
878The pump shall be suitable for the following requirements: Min. Actuating Pressure - 0.3 kg /sq cm; Max., working pressure - 2.5 kg/sq cm; Max., Temperature - 50 deg C; HP - 1/2 and Dosing flow range - 0 4 LPH
879Multigrade Filter: supplying, installation, testing and commissiong of multigrade sand pressure filter for litration of treatedsewage water. The filter shall be designed for a specific velocity of 4 m3/hr/sq.m area shall not be less then 16 Inch DIA with Minium HOS 65 Inch.
880The filtration unit shall comply with the following technical requirements: Flow rate - 4 cu.m/ hr Backwashduration - once in 24 hours for 20 min.Filtering Media - Multi grade of Sand / Pebbles: Pressure drop across unit -1.0 kg sq.cm (max) and dia of filter - 16 Inch, HOS - 65 Inch. MOC- FRP, operating pressure: 3.5 kg per sq. cm
881Further the filtration unit shall comprise the following:
882Thefiltershallbefittedwithinletdistributionandbottomcollecting system. Orifice board/ Rotameter for monitoring back wash flow to be fitted. Initial charge of underbed and carbon fotlering media as required. Complete set of valves, perssure gauge with needle valve and frontal pipe work done with Gray PVC pipes.
883ACTIVATEDCARBONFILTER(ACF):Supply, installation, testing and commissioning of activated carbon filter for filtration and removal of colour in treated sewage water. The filter shall be for 4 m3/hr flow rate and designed to operate for 12 hours.
884TheACFshallbedesignedforaspecificvelocityof4 m3/hr/sq.m area and the approx. dia shall not be less than 16 Inch DIA with 65 Inch HOS ( Height on straight ) of vessel.
885Further the filtration unit shall comprise the following:
886Thefiltershallbefittedwithinletdistributionandbottomcollecting system. Orifice board / Rotameter for monitoring back wash flow to be fitted. Initial charge of underbed and carbon filtering media as required. Complete set of valves, pressure gauge with needle valve and frontal pipe work done with Gray PVC pipe.
887FilterFeedPumps :Supply,Installation,testingandcommissioning of 2 Nos (1W + 1S) filter feed pumps, each ofspecifications : Pump Specification : 04 cum / hr; head : 25meter; 1.5/3HP; 2900RPM; inlet/ outlet 1.5"/2" (or) as per the OEM standard. ( Make - Jhonson / Kirloskar / KSB )
888PlantPiping : Supply, Installation, Testing Commisioning ofpipes & Valves with fittings suchastees, crosses, plugs, sockets, elbows, unions,flanges,sleevepieces, check nutsetcfor the entire STP Plant.
889a)Providing and fixing of MS pipes to I.S. 1239 including all fittings like bends, flanges, valves, etc., ( Make: Jindal / Tata )
890b) Inter connecting pipe works with valves for air line- Jindal/Eqv
891c) Inter connecting pipe works with valves for water line- PVC/UPVC
892Sewage TransferPumps :Supply,Installation,testingandcommissioning of 2 Nos (1W + 1S) Submersible pumps, each ofspecifications : Pump Specification : 04 cum / hr; head : 10meter; 1.5/3HP; 2900RPM; inlet/ outlet 1.5"/2" (or) as per the OEM standard. ( Make - Jhonson / Kirloskar / KSB )
893Sludge Re-circulation Pumps :Supply,Installation,testingandcommissioning of 2 Nos (1W + 1S) Re-circulation pumps, each ofspecifications : Pump Specification : 04 cum / hr; head : 25meter; 1.5/3HP; 2900RPM; inlet/ outlet 1.5"/2" (or) as per the OEM standard. ( Make - Jhonson / Kirloskar / KSB )
894Ultra Filtration Feed Pumps Capacity-3m3/Hour, Head-25-30 Meter
895Supplying, installing, testing & commissioning of Ultra Filtration System (UF) of Capacity 50 KLD, electro mechanical system (Excluding Civil construction)
896Electrical Panel Works:
897a) Supplying ,installaing ,testing and commissioning of Electrical panelsconsistingofMCCpanel(motorcontrolcenter)to accommodate all the drive units with cabling , glanding within the STP Compartmental,designIndoorwallmountedtypewithtopentryfor cabletheinternalcomponentseitherSiemen/ ABB Shallbeprovided with 1 no. Energy meter.
898To receive , control and distribute electrical power at440 V, 50Hz , ACinasheetsteelhouse.MCCistobemanufactured/assembled asperthelatestISIspecification,IndianElectricityRules,Including specialrequirementsofconcernedstateelectricityinspectorate.The switch board shall be fabricated out of 14 SWG sheet steel and shall be un cubical design.MCC of suitable rating to take care of full load of thesewagetreatmentplantincludingallmotorsandlighting.MCC shall be provided with the following feeders.
899Incoming Feeder : MCCB, Ernergy meter (Voltmeter with selector switch), LED type indication for 3 phases Outgoing Feeder: MCCB Motor feeder, 1 No 3 phase and netural of suitable capacity to be provided Busbar: Aluminium
900b) Power Cables (LT) for use on 415V system shallbeof 1100 volt grade, Aluminium conductor, PVC insulatedas per IS: 1554 (Part I). Motor up to 5 HP copper conductor cable should not be less than 1.5 sq mm of size to be used.
901c) Control Connector, Lugs / Sockets shall be of copper conductor and of Aluminium for conductor cable, suitable, solderless, crimping type.
902d)MCCpanelshouldhavenecessaryfeaturestooperatetheair blowers according to requirement of DO by means of VFD.
903e) Installation and wiring with fixing cable trays.
904Multi Utility Building at Koraput Medical College at Koraput(PH Works)
905Supplying all materials , labour, T&P and providing and fixing to wall or ceiling and floor PVC pipes conforming to C-PVC1785/89 ( Sch-80 ) and G.I pipe fittings of the following nominal bore with clamps including making good the wall,ceiling and floor ,testing all complete as per P.H. specification and direction of Engineer-in-charge .
906In ground floor
90720mm dia C-PVCPipe
90825mm dia C-PVCPipe
90940mm dia C-PVCPipe
910In 1st floor
91125mm dia C-PVCPipe
91240mm dia C-PVCPipe
913Supplying all materials,labour,T&P and cutting holes through existing brick work including making good the damages in cement mortar(1:4) for taking GI pipes and fittings/PVC pipes and fittings etc.all complete as per PH specification and direction of the Engineer-in-charge.
914In ground floor
915250mm thick wall
916Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proofas per P.H. specification and direction of Engineer-in-charge
917In ground floor
918Supplying all materials , labour, T&P and cutting grooves in pucca floors and walls for taking P.V.C pipes and G.I fittings etc. and making good the damagesincluding finishing complete as per P.H. specification and direction of Engineer-in-charge.
919In ground floor
920Supplying all materials , labour, T&P and fitting and fixing brass/CP fittings of following nominal bore with supply of all jointing materialscomplete as per P.H. specification and direction of Engineer-in-charge
92115mm C.P.Bib cock(CQT-CHR-23037)Jaqquar.
92215mm C.P.Pillar cock (DRC-CHR-37001)Jaquar.
92320mm dia CP Concealed Stop cock(FLR-IVC-5083N)Jaquar.
92415mm dia CP Angle Stop cock.(AQT-CHR-3059)
92515mm dia CP two way Bib Cock ( KLN-CHR-19041 )Jaquar.
926HEALTH FAUCET1.2 M TUBE(B FLOW PREVNTOR))(ALD-CHR-577)Jaquar.
92725mm dia brass fullway valve(Shakti Make)
92840mm dia brass fullway valve(Shakti Make)
92915mm dia. C.Pextension piece
93015mm dia. C.P flange
931125mm dia CP gratting
932Supplying all materials ,labour ,T&P and fixing 10 litres capacity PVC low level flushing cistern with a pair of PVC brackets complete with fittings such as pvc siphonic arrangements, 15mm dia nominal size pvc ball valve with polythene float ,pvchandles, unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet , and connecting the inlet pipe with supply mainetc.all complete as perspecification and direction of Engineer-in-charge
93310 ltrs. capacity PVC low level cistern (Slimline-white)
934Supplying all materials , labour, T&P and fixing rotational mouldedpolyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr widthKBbrickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 2.60m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxesetc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge.( Sintex/Supreem/Rotomax)
9352000 ltrs capacity rotational moulded polyethylene cylindrical vertical water storage tank .-In Ist. floor
936Sanitary Installation
937Supplying all materials,labour,T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No.13592/1992 to walls with nails,bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer"s specification,testing,earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of Engineer-in-charge
938110mm dia U-PVC SWR Pipe (Supreme/Ashirvad)
939110mm dia U-PVC Door Tee
940110mm dia U-PVC Plain Band
941110mm dia U-PVC Plain Tee
942110mm dia U-PVC Offset without ear
943110mm dia U-PVC Plain Shoe Bend
944110mm dia U-PVC Door Bend
945110mm dia U-PVC "P"Trap
946110mm dia U-PVC Cowl
947110mm dia U-PVC Socket plain
948Supplying all materials , labour, T&P and cutting holes through existing brickor laterite masonry wall for takingU-PVC / HCI pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge
949250mmto 375mmthick wall
950Supplying all materials, labour, T&P and cutting of R.C.C roof or cornice for taking H.C.I pipes and making good the damages etc all complete as per P.H.Specification and direction of the Engineer in charge.
951Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge
952Supplying all materials , labour, T&P andfixing Vitreous chinawater closet ,squattingpan ( Indian type W.C. pan / Orissa pattern squatting pan ) duly embedded in cement concrete 1:5:10 using hard granite metal 4cm nominal sizeincluding fixing a pair of vitreous china 250mmx130mmx30mm foot rest, fixing 100mm dia hci "P" or "S" trap for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge
953580mmx440mm size Orissa Pan ( White )
954Supplying all materials,labour,T&P and fitting and fixingvitrous Chaina washed down water Closet (European type water closet - EWC) with integral "P" or "S" type trap to the floor including wodden plug and chromoum plated screw including jointing the trap with soil pipe in CM(1:1) fixing plastic seat cover for washed down water closet with crmium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of Engineer-in-charge.
955European Water Clost "S" trap
956Supplying all materials ,labour ,T&P andfixing Wash basin with hole for pillar taps with cast iron or MS brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. fixing pedestralfor wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered "Hot" and "Cold" with long screws, shanks and back nuts of 15mm dia nominal bore, fixing15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin , fixing 12mm dia CP brass waste etc.all complete as perspecification and direction of Engineer-in-charge.
957550mmx400mm size wash hand basin with Porcelain pedestal
958Under Counterbasin(560x450)Hindware-No.10095
959Supplying all materials,labour,T&P and fixing standard sized Glass-shelf with C.P brass bracket and guard rail complete fixed to wooden pluges with screw etc.all complete as per specification and direction of Engineer-in-charge.
960600mmx125mm glass shelf with CP/NP guard rails
961Supplying all materials ,labour ,T&P andfixing standard sizedCP brass towel rail completewith CPbrass brackets fixed to wooden plugs with chromium plated brass screws etc.all complete as perspecification and direction of Engineer-in-charge
962Fixing 25mmx600mm long CP towel rail25mm x 600mm long CP towel rail(Jaquar)ACN-ACR-1111N
963CP towel Ring(Jaquar)ACN-ACR-1121N
964Supplying all materials ,labour ,T&P andfixing CP Soap Holder complete with CP brass bracketsfixed to wooden plugs with chromium plated brass screws etc.all complete as perspecification and direction of Engineer-in-charge
965CP soap holder (Jaquar)ACN-ACR-1131N
966Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted min 5mm thick on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge
967600mmx450mm size B.E mirror (fixed type)
968Large size mirror with frame(6x0.60x0.90)
969Supplying all materials, labour, T&P and providing kodappa slab in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge
970Supplying all materials, labour, T&P and providing granite tiles in slab, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles etc all complete as per direction of the Engineer in charge
971Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge
972Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
973Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
974Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,paymentof royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
975Fitting and fixing vetrified tiles with matt finish Kajaria ( Fog Perla or equivalent ) on floor or steps & landing on 25mm. Thick bed of cement mortar (1:1) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including cost conveyance, roylalities and taxes etc. all complete as per direction of Engineer-in-charge.(600mmx600mm)
976Fitting and fixing vetrified tiles with matt finish Kajaria ( Duren Marfil / Equvalant) to dados skirting & risers of steps on 12mm tick C.P(1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including cost conveyance, roylalities and taxes etc. all complete as per direction of Engineer-in-charge. (600mmx300mm)
977Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finishstructural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material,The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre"s standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter.
978Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigmentscomplete in all respect as per specification and direction of the Engineer in charge
979Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS UV of size 750x570x1350mm height with water storage capacity 120 liters along with 3 nos of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all completeas per approved drawing,specification and direction of the Engineer in charge.
980Aquagurd Pure Chill 120 PSS UV
981External S/D portion
982Supplying all materials, labour, T&P and constructing Gully Trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, Fly ash brickwork in c.m (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat ofneat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size C.I grating etc all complete as per approved drawing, specification and direction of the Engineer in charge
983Supplying all materials ,labour ,T&P and constructing Inspection Chamber ofinside size 760mmx760mmx460mmwith cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips,12mm thick cement plaster (1:3)with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxesetc.all complete as perapproved drawing, P.H specification and direction of Engineer-in-charge
984Inside size : 760mmx760mmx460mm
985Supplying all materials ,labour ,T&P and constructing Man Hole Chamber ofinside size 910mmx910mmx910mmwith cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips,12mm thick cement plaster (1:3)with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken black hard granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing, conveyance of all materials to worksite, payment of royalty, taxesetc.all complete as perapproved drawing, P.H specification and direction of Engineer-in-charge
986Inside size : 910mmx910mmx910mm
987Fitting and fixing RCPC cover slab (0.45m dia)
988Supplying all materials, labour, T&P & constructing Soak Way Pit of the following size with dry brick walling from bottom upto invert of inlet pipe andKB brick work in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size crusher broken hard black granite metal on bed, 12mm thick cement plaster in cement mortar (1:4) inside and outside over masonry brick work, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips fitted with iron lifting handles including earth work in open well excavation in all kinds of soil and refilling of cavity around the pit and painting the iron works, watering, curing,cost of all materials,conveyance of all materials to worksite, payment of royalty, all taxes etc. all complete as per approved drawing,PH specification and direction of the Engineer-in- charge.
9891.80m dia x 2.60m deep inside size Soakway Pit
990Supplying all materials,labour,T&P and laying in trenches ( to level or slope ) unplasticized PVC pipe conforming to IS:4985/2000 of the following outside dia for class-3 (0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/ as per manufactures"s providing and laying in trench cement concrete(1:4:8) with 40 mm size hard granite metal in the Type-C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer-in-charge.
991110mm dia U-PVC pipe ( Allround concrete )
992160mm dia U-PVC pipe ( Allround contrete )
993Sinking of 200mmx150mm dia Bore Well through DTH method.- 1 Nos.
994Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation(G.I/P.V.C/M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only
995Drilling of 200mm dia bore0 to 30 mtr
996Drilling of 200mm dia bore31 to 45 mtr
997Drilling of 150mm dia bore41 to 125 mtr
998Labour for lowering the following size of PVC casing pipes with or without slotted pipes as per necessity from ground level upto 300 mtrs depth and fitted and set up in perfectly vertical position including cutting and threading of blank pipes and slotted pipes and supplyinging and fixing of all jointing materials ,extra sockets and T&P etc. all complete and keeping the top of casing pipe threaded including plugging the tubewell to prevent entry of foreign materials
999Lowering of 200mm dia PVC casing pipes 0 mtr to 30 mtrs
1000Lowering of 200mm dia PVC casing pipes 31 mtr to 45 mtrs
1001Cost of 200mm dia PVC schedule - 80 pipe
1002Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge
1003Supplying all materials,labour,T&P andproviding around sealing by cement concrete grouting of annualr space around GI/PVC housing pipe upto 5 mtr below ground level ( as per drawing ) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer-in-charge . Mimimum one meter of casing pipe to nserted in the bore in to the rock the bottom to ensure sanitary sealing ( excluding cost of cement which willbe supplied by the Department )
1004Sanitary sealing upto 5 mtr below ground level
1005Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
10061x5x3.14x(0.15-0.10)
1007Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing,commissioning,trial running,conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge.
10082HP Three Phase 3 stage submersible pump set.
1009DOL control panel
101050mm S. S. Nipple, S. S. bolt & clips
101150mm M. S. Clamp, Bend, Socket & 200mm M. S. well cap
10122.50mm Sqm Submersible flat cable
1013Steel rope with cover
101420mm dia rigid U-PVC pipe
101550mm dia HDPE pipe
1016Labour charges for lowering, testing, commissioning & transportation to site etc.
1017Instalation of 1.5 HP submerssible pump-motor
1018Supplying all materials, labour, T&P and providing fitting & fixing submerssible pump with squirrel cage induction type submerssible electric motor to run single-phase line voltage ranging from320 to450 volt confirm to IS 8034/89 with following specification suitable control pannel jointing with GI/PVC/HDPE pipe, electrification, testing, commissioning , trial running, conveyance of all materialto work site, payment of all taxces etc all complete as per PH specification and direction of Engineer-in-charge.
10191.5 H.P single phase 3 stage head range 20 to 35 metres, discharge 145 to 110L.P.M with outlet dia of 25mm
1020DOL contol pannel suitable for 1.5HP pump
10212.50 sqmm flate cable
102250mm dia steel short piece
102350mm dia C.I Bracket
102450mm diaHDPEPipes
102525mm dia rigid U-PVC pipe
1026Well cap
1027Steel rope with cover
1028Supplying all materials, labour, T&P and constructingBore well protectionchamber of the inside size 650x650x1000hightwith cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ashbrickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:4)inside and outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.
1029Bore well chamber
1030Construction of 20 users Brick Septic Tank- 1 No.
1031Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of theEngineer-in-Charge.
1032Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general.
1033Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
1034Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12m size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
1035Supplying all materials, labour, T&P and providing brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
1036In F&P
1037Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
1038In ground floor
1039Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
1040Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
1041R.C.C floor androofslabs
1042Supplying all materials, labour, T&P and providing M.Sreinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
1043Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge.
1044Supplying all materials, labour, T&P and providing,fitting and fixing 100mm x 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification anddirection of the Engineer in charge
1045Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls ofman hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
1046Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail