Civil Engineering Department has published Tender For Construction Of New Girls Hostel Building (G Plus 5) And Multi Utility Building (Renovation) At Govt Medical College Koraput.. Submission Date for this Tender is 27-01-2023. Building Repair Tenders in koraput Odisha. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | CIVIL WORK Providing jungle cutting uprooting buses below 1.00m girth with cost of all labour and T&P required for the work etc. complete. |
2 | SITE CLEARANCE |
3 | Dismantling brick or stone masonry in lime or cement mortar above 3m height including stacking the useful materials for re-use and removing the debris with in 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge. |
4 | Under 3.0mt (MUB) |
5 | Above3.0mt (MUB) |
6 | SITE CLEARANCE |
7 | Dismantling and removing R.C.C. columns beams slab staircase landing lintels including stacking the useful materials for reuse and removing the debris within 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge. |
8 | Stilt floor (MUB) |
9 | Dismantling and removing R.C.C. Chajja, Shelves, fins and parapet including stacking the useful materials for reuse and removing the debris within 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge. |
10 | Stilt floor (MUB) |
11 | Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead including cost of all labour with T&P etc. complete as per the specification and direction of the Engineer-in-charge. |
12 | Stilt floor (MUB) |
13 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.50m initial lift including rough dressing breaking clods maximum 5cm to 7cm & laying in layers not exceeding 0.3m depth for the work complete including shoring, shuttering & dewatering (if required) with cost of all Labour, Labour cess ,Hire & Running charges of thewater pumps, Sundries, T & P required for the work complete as directed by the Engineer- in- charge. |
14 | All type of soil (Hostel) |
15 | All type of soil (MUB) |
16 | RETAINING WALL |
17 | SITE CLEARANCE |
18 | Carriage of earth by mechanical means with cost of all labour and T&P required for the work etc. complete. (Upto 5km). |
19 | MUB |
20 | SITE CLEARANCE |
21 | Filling in foundation trenches and plinth, with excavated earth including laying the earth in layers not exceeding 23.5 cm thick ramming & watering with all leads & lifts including cost of all labour,T&P completed as directed by the Engineer-in-charge. |
22 | HOSTEL BUILDING |
23 | MUB |
24 | Supplying and filling in foundation trenches and plinth, ditches with sand well watered and rammed in layers not exceeding 23 cm. in depth with all lead and lift including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,labour cess, sundries, T&P required for the work etc. complete in all respect as per direction by the Engineer in charge. (Measurement will be taken on finished compacted section only). |
25 | HOSTEL BUILDING |
26 | MUB |
27 | RETAINING WALL |
28 | Diluting and injecting chemical emulsion (to be supplied free of cost at site of work) for PRE CONSTRUCTIONAL Anti-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (plinth area of the building at ground floor only shall be measured for payment). |
29 | HOSTEL BUILDING |
30 | MUB building |
31 | Providing and lying plain cement concrete of proportion (1:3:6) in foundation and floors using Portlandslag cement (PSC) with 40 mm. Size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties and taxes all materials and cost all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per the instruction of the Engineer-in-Charge. |
32 | HOSTEL BUILDING |
33 | MUB building |
34 | RETAINING WALL |
35 | Providing and lying plain cement concrete of proportion (1:3:6) in foundation and floorsusing Portland Slag Cement (PSC) with 12mm. Size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete to required levels laid in layers not exceeding 15 cm thick in each layer including cost, conveyance, loading, unloading, royalties and taxes all materials and cost all labours, sundries, T & P required for the work including shoring, shuttering and dewatering if required including hire & running charges of water pump complete as per specification anddirection of Engineer-in-charge. |
36 | HOSTEL BUILDING |
37 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 250 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed andcleaned ( 20mm. size chips not to exceeds 25 % ) to be mixed in concrete mixture with Portlandslag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position. |
38 | HOSTEL BUILDING |
39 | Footing |
40 | Column up to PlLvl |
41 | Tie/Plinth Beam |
42 | MUB |
43 | Footing |
44 | Column up to PlLvl |
45 | Tie/Plinth Beam |
46 | RETAINING WALL |
47 | Footing |
48 | Retaining wall base 350mm top 230mm |
49 | Column up to Roof Lvl :- |
50 | HOSTEL BUILDING |
51 | Stilt floor |
52 | First Floor |
53 | Second Floor |
54 | Third Floor |
55 | Fourth Floor |
56 | Fifth Floor |
57 | Mumty Floor |
58 | MUB |
59 | Ground floor |
60 | LINTEL :- |
61 | HOSTEL BUILDING |
62 | Stilt floor |
63 | First Floor |
64 | Second Floor |
65 | Third Floor |
66 | Fourth Floor |
67 | Fifth Floor |
68 | Mumty Floor |
69 | MUB |
70 | Ground floor |
71 | CHAJJA:- |
72 | HOSTEL BUILDING |
73 | Stilt floor |
74 | First Floor |
75 | Second Floor |
76 | Third Floor |
77 | Fourth Floor |
78 | Fifth Floor |
79 | Mumty Floor |
80 | MUB |
81 | Ground floor |
82 | ROOF BEAM:- |
83 | HOSTEL BUILDING |
84 | Stilt floor |
85 | First Floor |
86 | Second Floor |
87 | Third Floor |
88 | Fourth Floor |
89 | Fifth Floor |
90 | Mumty Floor |
91 | MUB |
92 | Ground floor |
93 | ROOF SLAB:- |
94 | HOSTEL BUILDING |
95 | Stilt floor |
96 | First Floor |
97 | Second Floor |
98 | Third Floor |
99 | Fourth Floor |
100 | Fifth Floor |
101 | Mumty Floor |
102 | MUB |
103 | Ground floor |
104 | STAIRCASE:- |
105 | HOSTEL BUILDING |
106 | Stilt floor |
107 | First Floor |
108 | Second Floor |
109 | Third Floor |
110 | Fourth Floor |
111 | Fifth Floor |
112 | LIFT WALL:- |
113 | HOSTEL BUILDING |
114 | Stilt floor |
115 | First Floor |
116 | Second Floor |
117 | Third Floor |
118 | Fourth Floor |
119 | Fifth Floor |
120 | Mumty Floor |
121 | SHELVES (37.5mm):- |
122 | HOSTEL BUILDING |
123 | Stilt floor |
124 | First Floor |
125 | Second Floor |
126 | Third Floor |
127 | Fourth Floor |
128 | Fifth Floor |
129 | Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / TATA / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. includingbending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge. |
130 | HOSTEL BUILDING |
131 | Stilt floor |
132 | First Floor |
133 | Second floor |
134 | Third floor |
135 | Fourth floor |
136 | Fifth floor |
137 | Terrace Floor |
138 | MUB |
139 | RETAINING WALL |
140 | Providing weepholes in retaining wall, drain covers etc with 50mm pipe |
141 | RETAINING WALL |
142 | Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. |
143 | HOSTEL BUILDING |
144 | MUB |
145 | Fly Ash brick masonry in cement mortar (1:6) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. |
146 | HOSTEL BUILDING |
147 | Stilt floor |
148 | First Floor |
149 | Second floor |
150 | Third floor |
151 | Fourth floor |
152 | Fifth floor |
153 | Terrace Floor |
154 | MUB |
155 | Fly Ash brick masonry in cement mortar (1:4) in super structure using Fly Ash bricks of 23 x 11 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties of all materials with all labour,labour cess and T & P required for the work complete in all respect as per direction of Engineer-in-Charge. |
156 | HOSTEL BUILDING |
157 | Stilt floor |
158 | First Floor |
159 | Second floor |
160 | Third floor |
161 | Fourth floor |
162 | Fifth floor |
163 | MUB |
164 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
165 | HOSTEL BUILDING |
166 | Stilt floor |
167 | First Floor |
168 | Second floor |
169 | Third floor |
170 | Fourth floor |
171 | Fifth floor |
172 | Terrace Floor |
173 | MUB |
174 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
175 | HOSTEL BUILDING |
176 | Stilt floor |
177 | First Floor |
178 | Second floor |
179 | Third floor |
180 | Fourth floor |
181 | Fifth floor |
182 | Terrace Floor |
183 | MUB |
184 | Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
185 | HOSTEL BUILDING |
186 | Stilt floor |
187 | First Floor |
188 | Second floor |
189 | Third floor |
190 | Fourth floor |
191 | Fifth floor |
192 | Terrace Floor |
193 | MUB |
194 | Supplying, fitting and fixing vetrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Color / Printed series (Homogenous) of approved make (OASIS / SOMANY/ KAJARIA or equivalent) in floors on 20mm thick bed of C.M. (1:4) (1cement:4course sand) and filling the joint with white cement mixed with pigment to match the shades of the tile including cost of all materials, labour, labour cess, T&P etc. required for the work completein all respect as directed by the Engineer in charge. |
195 | HOSTEL BUILDING |
196 | Stilt floor |
197 | First Floor |
198 | Second floor |
199 | Third floor |
200 | Fourth floor |
201 | Fifth floor |
202 | MUB |
203 | Providing, fitting, fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Color / Printed series (Homogenous)of approved make (OASIS / SOMANY/ KAJARIA or equivalent )as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects. |
204 | HOSTEL BUILDING |
205 | Stilt floor |
206 | First Floor |
207 | Second floor |
208 | Third floor |
209 | Fourth floor |
210 | Fifth floor |
211 | MUB |
212 | Providing and fixing 20mm thick mirror polished granite stone slab, machine cut stone (sample of granite should be approved by EIC) for kitchen platforms, vanity counters, facias and similar locations where ever required in horizontal/vertical surfaces of required size of approved shade, colour and texture, with moulding edge, making gas pipe hole etc. laid over 25mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) with joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to give high gloss finish etc. complete as per direction of Engineer-in-charge. In all floors and all heights.In all floors and all heights. |
213 | HOSTEL BUILDING |
214 | Stilt floor |
215 | First Floor |
216 | Second floor |
217 | Third floor |
218 | Fourth floor |
219 | Fifth floor |
220 | Terrace floor |
221 | MUB |
222 | Fixing granite tiles of approved dimension area above 0.1 up to 0.4 sqm (10mm thick) in Dados, treads of steps and landing on 12mm thick cement mortar (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects as per direction of Engineer-in-Charge. |
223 | HOSTEL BUILDING |
224 | Stilt floor |
225 | First Floor |
226 | Second floor |
227 | Third floor |
228 | Fourth floor |
229 | Fifth floor |
230 | Terrace floor |
231 | MUB |
232 | Providing and layinganti-skid Matte Finish Vetrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 300mm x 300mm plain (Ivory)of approved make (OASIS / SOMANY/ KAJARIA or equivalent ) in floors on 20mm thick bed of C.M. (1:4) (1cement:4course sand) and filling the joint with white cement mixed with pigment to match the shades of the tileincluding cost of all materials, labour, labour cess, T&P etc. required for the work completein all respect as directed by the Engineer in charge. |
233 | HOSTEL BUILDING |
234 | MUB |
235 | Fixing of Ceramic Glazed Wall Tiles of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13753 of size 30cm x 20cm / 20cm x 20cm special plain / printed series in dados skirting & riser of steps on 12mm thick cement plaster 1:3 joined with neat cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance,royalties of all materials, labour with T&P complete in all respects as per direction of Engineer-in-Charge. |
236 | HOSTEL BUILDING |
237 | MUB |
238 | Fixing of Chequered tiles of premium grade having thickness 7mm to 8mm confirming to IS 13755 of size 30cm x 30cm special plain / printed series in floors over 20mm thick bed of cement mortar 1:4 jointed with cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance, taxes & royalties of all materials, labour with T&P complete in all respects as per direction of Engineer-in-Charge. |
239 | HOSTEL BUILDING |
240 | Providing fitting fixing of inter locked paver block of size 80 mm thick and filling the joints with sand of approvedv quality including rubbing & polishing etc comleteincluding costof all materials, labour with T&P etc. complete in all respect. |
241 | HOSTEL BUILDING |
242 | MUB |
243 | Dressed seasoned sal woodworkframed andfixedinframesofdoors&windows including cost,conveyanceofall materials and cost of labour for fitting, fixing etc.complete as per the instruction of Engineer-in-Charge . |
244 | HOSTEL BUILDING |
245 | Stilt floor |
246 | First Floor |
247 | Second floor |
248 | Third floor |
249 | Fourth floor |
250 | Fifth floor |
251 | MUB |
252 | Providing and fixing ISI marked32mm flush door shutters with 1mm laminates pasted both side confirming to IS 2202(Part1) including ISI marked necessary hardware fitting with approved colour paint over a coat of primer etc and hardware fittings such as, SS Concil Hinges (5"),stopper,Door magnet,SS Tower bolt,Pull handle/Mortise lock Handle,Cylinder coin & knob key & knob ,SS lock body and Door closer etc. includingcost of all labours, materials, conveyance, hardware fixing,loading and unloading, all taxes and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge. |
253 | HOSTEL BUILDING |
254 | Stilt floor |
255 | First Floor |
256 | Second floor |
257 | Third floor |
258 | Fourth floor |
259 | Fifth floor |
260 | MUB |
261 | Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride(UPVC) ( FENESTA / NCL VEKA LTD.)Three Track - Three Panel sliding window– 60- Series duly manufactured using UPVC reinforced profiles of 108mm x 45 mm x 2.5 mm for outer frames and Window Sash of 39 mm x 58 mm x 2.5 mmcapable of mounting singleglazing system, structurally reinforced with hot dip galvanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window frame shall be fitted with 6 mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistantand the system is to be installed using Reinforced Large Coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc., including cost and conveyance of all materials, accessories, labour charges, materials andproduct conforming to ASTM D 638-14,EN-477-95 and other applicable codes and standards. |
262 | HOSTEL BUILDING |
263 | Stilt floor |
264 | First floor |
265 | Second floor |
266 | Third floor |
267 | Fourth floor |
268 | Fifth floor |
269 | MUB |
270 | Supplying, fitting & fixing in all floors of M.S. grills, grill gates, M.S. gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of M.S Square bar/ flat including stair case hand railing with 40mm. dia G.I.pipe etc. including painting two coats over a coat of redoxide primer as per approved drawing and designwith cost of all materials & labour, labour cess, T&P, sundries etc. complete in all respect as per specification & direction of the Engineer-in-Charge. |
271 | HOSTEL BUILDING |
272 | Stilt floor |
273 | First Floor |
274 | Second floor |
275 | Third floor |
276 | Fourth floor |
277 | Fifth floor |
278 | Terrace |
279 | MUB |
280 | Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge. |
281 | HOSTEL BUILDING |
282 | Stilt floor |
283 | First Floor |
284 | Second floor |
285 | Third floor |
286 | Fourth floor |
287 | Fifth floor |
288 | Terrace Floor |
289 | MUB |
290 | Painting two coats with approved antifungal weather seal paints (ISI) of approved colour, shade on wall surface over a coat of wall primer(ISI) water bound including sand papering, polishing the surface, cost, conveyances, taxes of all materials and cost of all labour,labour cess with T&P etc, complete as per specification & direction of Engineer-in-charge. |
291 | HOSTEL BUILDING |
292 | Stilt floor |
293 | First Floor |
294 | Second floor |
295 | Third floor |
296 | Fourth floor |
297 | Fifth floor |
298 | Terrace Floor |
299 | MUB |
300 | Finishing plastered surfaces of walls with water based wall putty of approved make and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. |
301 | HOSTEL BUILDING |
302 | Stilt floor |
303 | First Floor |
304 | Second floor |
305 | Third floor |
306 | Fourth floor |
307 | Fifth floor |
308 | Terrace Floor |
309 | MUB |
310 | Painting two coats with plastic emulsion paint "Royale Shyne"to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge. |
311 | HOSTEL BUILDING |
312 | Stilt floor |
313 | First Floor |
314 | Second floor |
315 | Third floor |
316 | Fourth floor |
317 | Fifth floor |
318 | Terrace Floor |
319 | MUB |
320 | Painting two coat with approved synthetic enamel paint to new wood & iron work over a coat of Red oxide primer including cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge. |
321 | HOSTEL BUILDING |
322 | Stilt floor |
323 | First Floor |
324 | Second floor |
325 | Third floor |
326 | Fourth floor |
327 | Fifth floor |
328 | Terrace Floor |
329 | MUB |
330 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance of all materials, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge. |
331 | HOSTEL BUILDING |
332 | Stilt floor |
333 | First Floor |
334 | Second floor |
335 | Third floor |
336 | Fourth floor |
337 | Fifth floor |
338 | MUB |
339 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well ramed, consolidated and grouted with fine sand and finishing the top smooth including shuttering at the edges, excavation and disposing of surplus earth with a lead of 100m. |
340 | HOSTEL BUILDING |
341 | MUB |
342 | Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) using 6mm size black hard granite crusher broken chips and screened & washed sharp sand for mortar and finished smooth to the rough surface of slab including watering and curing with cost, conveyance, royalties of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as directed by the Engineer in charge. |
343 | HOSTEL BUILDING |
344 | Terraace Floor |
345 | MUB |
346 | Supply of all materials & laying the waterproofing material of Dr.Fixit torch shield P3160(3mm)with its primer 2 coats or equivalent water proofing material after drying cleaning the concrete surface over the concrete floor/roof/ balcony/ sunken and dado upto 1"6" in wall including cleaning, applying and mending as per specification including cost,conveyance, taxes, royalities of all materials to work site etc.all complete as per the direction of the Engineer-in-charge. |
347 | Terraace Floor |
348 | Providing, and applying two coat of primer 7E in both surface of expansion joint followed by applying polysulphide sealant Thioflex 600 on vertical joint surface after proper fixing of the necessary backup materialsas specified including cost ,conveyance ,taxes of all materials ,Labour, transportation charges etc. complete as per specification and direction of the Engineer-in-charge. |
349 | Manufacturing, Providing and Fixing of (Glass Fibre ReinforcedConcrete) GFRC Jali/ Screen, make ""Samudyam or equivalent"" of thickness 25mm+/- 5mm with border thckness 50 +/- 10mm pattern, design and color of approved make to be fixed on/between RCC/Block work column or structural work with dry fixing method with appropriate frame work, using fastners and necessary hardware in building facade. The element shall be made from 53 grade portland cement make Birla/ JK cement or equivalent, quartz, fine silica sand, alkali resistant glass fibre make "OC" or equivalent, super plasticizer/ adhesives (make _BASF or equivalent) polymers and UV resistant synthetic inorganic pigments shall be used for pigmentation make " BAY FERROX" or equivalent. The material casting shall take place in synthetic rubber/ FRP mould manufactured by mould toolof revex/ reckli or equivalent. |
350 | Stilt floor |
351 | First floor |
352 | Second floor |
353 | Thrd floor |
354 | Fourth floor |
355 | Fifth floor |
356 | E.I. WORK INTERNAL WIRING.( Make of wire Finolex/ L&T / Anchor / Havels / V Guard /RR/eq make) Recessed wiring to light point / first light of group control/ call bell point/ exhaust fan point /wall fan point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit (NORPACK/Eq make) with 6 Amp, 250 V clip in type switch ISI marked and ceiling rose ISI marked mounted on G.I modular box with face plate & cover of suitable size ,with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge.Group C |
357 | Recessed wiring to secondary light pointlooped from primary light point with 1.5sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduitwith 1.5sqmm FR PVC insulated single core multistrand copper conductor for running earth including3 plate ISI marked Ceiling rose with all accessories & connection as per direction of Engineer in charge. ) Average Length: 3mtr |
358 | Recessed wiring to ceiling fan point with 1.5sqmm FR PVC insulated single core multistrand copper conductor of ISI marked with 20mm dia non-metallic PVCconduit (NORPACK/Eq make)with 6Amp 250V Modular Switch,Stepped type Moudular Regulator, Base & Cover with 1.5sqmm FR PVC insulated single core multistrand copper conductor for running earth including all accessories & connection as per direction of Engineer in charge. |
359 | Recessed wiringfor 5 / 6 amp socket outletwith6Amp, 250 V clip in type modular switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on same switch board as per direction of Engineer in Charge. |
360 | Recessed wiringfor 5 / 6 amp socket outlet with 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked in 20 mm dia non-metalic PVCconduit (NORPACK/Eq make) with 6Amp, 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable size ,with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection on separate board as per direction of Engineer in Charge. ( Make of wire Finolex/ L&T / Anchor / Havels / V Guard ) |
361 | Recessed wiringfor2 x 6 amp socket outlet controlled by 2 nos6Amp, 250 V clip in type switch ISI markedmounted on single G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection on separate board as per direction of Engineer in Charge. |
362 | Recessed wiringfor 6 pin 16 amp socket outletwith 16Amp, 250 V clip in type switch ISI markedmounted on G.I moular box with face plate & cover of suitable sizeincluding all accesories and connection as per direction of Engineer in Charge. |
363 | PointwiringforProjector/A.C socket outlet with 16A plug socketand 16Acontrol switch atnearest separate location. |
364 | Recessed wiringfor A.Csocket outletwith 20 amp SPN, industrial type socket outlet, with plug top and metal chained cover in sheet steel enclosure indusrial socket ,20A SP MCBincluding all accesories and connection as per direction of Engineer in Charge. |
365 | SUBMAIN. |
366 | Recessed wiring to submain in 4 x 16sq.mmFR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 50 mm dia non-metalic heavy duty PVC conduit(NORPACK/Eq make) along with 2 x 10 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (PDB) |
367 | Recessed wiring to submain in 4 x 10 sq.mmFR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 40 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick (NORPACK/Eq make) along with 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired.(For PDB ) |
368 | Recessed wiring to submain in 4 x 6sq.mmFR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 32 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 2 x 4.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (For LDB) |
369 | Recessed wiring to submain in 2 x 6 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 25 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick (NORPACK/Eq make) along with 1 x 4.0 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. (For EDB & 2TR AC) |
370 | Recessed wiring to submain in 2 x 4 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. |
371 | Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick (NORPACK/Eq make) along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. |
372 | Recessed wiring to submain in 2 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick (NORPACK/Eq make) along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. |
373 | DISTRIBUTION BOARD .L&T/ Hager/ Legrand/ Siemens/ Panasonic/Eq make |
374 | Supply and fixing of following way three pole and neutral, sheet steel, MCB distribution, 415 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, hinged front acrylic cover for the MCB knobs detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ Isolator) |
375 | 4 way (4 + 12) TPN double doorhorizontal type |
376 | 6 way (4 + 18 ), TPN , MCB DB double doorhorizontal type |
377 | Supply and fixing of single pole MCB with sheet steel enclosure, distribution board, on surface /recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnection, phosphate and powder painted including earthing etc. as required ( But with out MCB/ RCCB/ ISOLATOR) |
378 | 4 way SPN , MCB DB double door |
379 | 8 way SPN , MCB DB double door |
380 | 8 way SPN , MCB DB double door |
381 | 12 way SPN , MCB DB double door |
382 | Supply and fixing of following rating 240 V Minature Circuit Breaker (MCB) having a sensitivity current up to 10kA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required. |
383 | 6 amp to 32 amp rating SP MCB , "c" series, 10KA breaking capacity |
384 | Supply and fixing of following rating 240 V Residual Current Breaker with Overcurrent protection (RCBO) having a sensitivity current up to 100mA in the existing MCB DB ISI marked complete with connection testing and commissioning etc as required. |
385 | 25 to 40 amp rating DP RCBO, 30mA |
386 | 25 amp rating FP RCBO, 30mA |
387 | 32 amp rating FP RCBO, 30mA |
388 | 40 amp rating FP RCBO, 100/300 mA |
389 | 63 amp rating FP RCBO, 100/300 mA |
390 | CABLE .RR/KEI/eq make |
391 | Supplyof one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of following sizes of cable as required. |
392 | 3.5 C x 300 sq.mm Al |
393 | 3.5 C x185sq.mm Al |
394 | 3.5 C x150sq.mm Al |
395 | 3.5 C x95sq.mm Al |
396 | 3.5 C x70sq.mm Al |
397 | 3.5 C x 50 sq.mm Al |
398 | 3.5 C x 25 sq.mm Al |
399 | 4 C x 16 sq.mm Al |
400 | Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation, sand cushing, protective covering and refilling the trench etc. as required. |
401 | Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size excedding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc. as required. |
402 | Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size excedding 120 sq.mm but not exceeding 400 sq.mm direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc. as required. |
403 | Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground in the same trench in one tier horizontal formation including excavation , sand cushining protective covering and refilling the trench etc. as required. |
404 | Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground in the same trench in one tier horizontal formation including excavation , sand cushining protective covering and refilling the trench etc. as required. |
405 | Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size excedding 120 sq.mm but not exceeding 400 sq.mm direct in ground in the same trench in one tier horizontal formation including excavation , sand cushining protective covering and refilling the trench etc. as required. |
406 | Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground in the existing RCC/HUME/STONEWARE/METAL pipe as required. |
407 | Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade ofsize exceeding 25 sq.mm but not exceeding 400 sq.mm in the existing RCC/HUME/STONEWARE/METAL pipe as required. |
408 | Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface as required. |
409 | Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm on surface as required. |
410 | Laying and fixing of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm on surface as required. |
411 | END TERMINATION |
412 | Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required. |
413 | 3.5 C x 300 sq.mm Al |
414 | 3.5 C x185sq.mm Al |
415 | 3.5 C x150sq.mm Al |
416 | 3.5 C x95sq.mm Al |
417 | 3.5 C x70sq.mm Al |
418 | 3.5 C x 50 sq.mm Al |
419 | 3.5 C x 25 sq.mm Al |
420 | 4 C x 16 sq.mm Al |
421 | PANEL:L&T/Hager/Siemens/Legrand/eq make |
422 | Supply, installation,testing & commissioning of floor mounting front operated front access extensible type cubicle panel totally enclosed, dust and vermin proof with IP-42 /55 protection with hinged and lockabale doors.CRCA sheets including Busbars,interconnections,tinned copper crimping lugs, bonding to earth and painting suitable for use at 415 V, 3phase 4 wire 50 Hz system, and to withstand a fault level of 35KA symmetrical for 1 sec at 415 V complete as per specifications, as required and as below : All switchboards shall have provision for entry of cables from the bottom as required. All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The bus bars shall be insulated with heat shrinkable sleeves.SMC/DMC shrouds and busbar supports shall be used. |
423 | MAIN LT PANEL with 800A 4P Micro Processor Based EDO ACB (50kA)-1 Nos as incomer, 630A 4P MCCB (50kA) -3 Nos, 200A 4P MCCB (50kA) -2 Nos, 63A 4P MCB-2 Nos, 32A 2P MCB-6 Nosas Outgoing. |
424 | MAIN ESSENTIAL PANEL with 200A 4P C/O Switch -1 No &200A 4P MCCB (50kA) -1 No as incomer, 125A 4P MCCB (36kA) - 2 No, 100A 4P MCCB (36kA) - 3 Nos, 63A 4P MCB- 2 Nos, 32A 2P MCB-6 Nos as Outgoing. |
425 | MAIN NON-ESSENTIAL PANEL with 800A 4P C/O Switch -1 No &630A 4P MCCB (50kA) -1 No as incomer, 200A 4P MCCB (36kA) - 3 No, 125A 4P MCCB (36kA) - 2 Nos, 63A 4P MCB- 2 Nos, 32A 2P MCB-6 Nos as Outgoing. |
426 | ZONE-1/3 PANEL (ESSENTIAL) with 100A 4P MCCB (36kA) -1 No as incomer, 40A 4P MCB- 2 Nos, 32A 4P MCB- 8 Nos, 32A 2P MCB-6 Nos as Outgoing. |
427 | ZONE-2 PANEL (ESSENTIAL) with 125A 4P MCCB (36kA) -1 No as incomer, 40A 4P MCB- 3 Nos, 32A 4P MCB- 11 Nos, 32A 2P MCB-6 Nos as Outgoing. |
428 | ZONE-1/2 PANEL (NON-ESSENTIAL) with 200A 4P MCCB (36kA) -1 No as incomer, 63A 4P MCB- 6 Nos, 40A 4P MCB- 10 Nos, 32A 2P MCB- 6 Nos as Outgoing. |
429 | ZONE-3 PANEL (NON-ESSENTIAL) with 125A 4P MCCB (36kA) -1 No as incomer, 63A 4P MCB- 6 Nos, 40A 4P MCB- 2 Nos,32A 2P MCB- 6 Nos as Outgoing. |
430 | EXTERNAL LIGHT PANEL with 63A 4P MCB- 1 No as incomer, 32A 4P MCB- 3 Nos, 32A 2P MCB-9 Nosas Outgoing. |
431 | Automatic Power Factor Correction Panel of 220 kVAR capacity suitable for 440 Volts 3 phase 50 c/s & having APP type heavy duty 525v , self fusing, low loss, self healing, resin bonded without oil, three phase delta connected capacitors (confirming to IS:2834 IS:13346 IEC-831/1-2, & IEC-439(1-2), housed in alluminum cans & having current limiting contacts circuit to suppress switching in rush current & having 12 step microprocessor based APFC relay with digital displaycontrolling capacitors of rating5,10,20, 25 & 50 kVAr for improvement of targeted P.F. of the system & provided with 630 Amps 4P MCCB (50kA) and set of 600/5 CTs with Digital Ammeter and selector switch, capacitor duty contactors with 3Pole MCCB of suitable rating , auto manual selector switch, ON/OFF indicating lamp and push button, 1 No 800/5 CT in the the main panel, including interconnection and control wiring with copper cable etc. complete with 14% detuned reactor as required.10kVArshall be of fixed type. |
432 | MAIN PANEL with 200A 4P C/O Switch, 160A 4P MCCB (36kA) - 1 No as incomer, 40A 4P MCB - 5 Nos followed by 10-40A 3P kWH Energy Meter, 32A 2P MCB- 12 Nos followed by 5-30A 1P kWH Energy Meter with 32A DP Contactor & Timer- 1 Nos as Outgoing and 3nos 160/5A CT, 0-160A Digital Ammeter and 160A aluminium Bus Bars. |
433 | EARTHING |
434 | Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (But wih out charcoal and salt) as required. |
435 | Earthing with G.I. earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (But wih out charcoal and salt) as required. |
436 | Extra for using salt and charcoal for G.I or copper plate earth as required |
437 | Providing and fixing 25 mm x 5 mm Copper strip in 40 mm dia G.I. pipe from earth electrode as required. |
438 | Supplying and laying 25 mm x 5 mm copper strip on surface or in recess for connection etc as required. |
439 | Supplying and laying 25 mm x 6 mm G.I earth strip ISI marked at 0.5 meter below ground level as strip earth electrode including soldering etc. as required. |
440 | Supplying and laying 25 mm x 5 mm G.I earth strip ISI marked on surface or in recess for connection etc as required. |
441 | Providing and fixing 8 SWG (4 mm) dia copper wire on surface or in recess for loop earthing as required. |
442 | LIGHTNING ARRESTOR |
443 | Providing and fixing of lightning conductor finial made of 25mm dia 300 mm long, G.I tube,having single prong at top,with 85mm dia 6 mm thick G.I base plate including holes etc. complete asrequired. |
444 | Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) |
445 | Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run) |
446 | Providing and fixing of testing joint, made of 20 mm x 3 mm thick G.I. strip, 125 long with 4 nos of G.I. bolts, check nuts and spring washer etc complete as required. |
447 | Providing and fixing of lightning conductor finial made of 25mm dia 300 mm long, copper tube,having single prong at top,with 85mm dia 3 mm thick copper base plate including holes etc. complete asrequired |
448 | Providing and fixing of copper tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) |
449 | Providing and fixing of copper tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run) |
450 | Providing and fixing of testing joint, made of 20 mm x 3 mm thick Copper strip, 125 long with 4 nos of G.I. bolts, check nuts and spring washer etc complete as required. |
451 | Reveting, sweating and soldering of copper / G.I. tape ( with another copper / G.I. tape, base of the finial or any other metallic object) as required |
452 | Providing and laying of G.I. tape 32 mm x 6 mm from earth electrode directly in ground as required. |
453 | Providing and laying of copper tape 32 mm x 6 mm from earth electrode directly in ground as required. |
454 | Earthing with G.I. earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (But wih out charcoal and salt) as required. |
455 | Earthing with copper earth plate 600 mm x 600mm x 3.15 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (But wih out charcoal and salt) as required. |
456 | Extra for using salt and charcoal for G.I or copper plate earth as required |
457 | FIXTURE |
458 | Supply, Installation, Testing and Commissioning of pre-wired fluorescent fiiting / compact fluorescent fitting /LED fitting of all sizes complete with all accessories and lamp etc. directly on ceiling /wall or recessed in false ceiling , including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor and earthing as required. |
459 | Surface mounted indoor type 18W SINGLE LED TUBELuminaire with LED Lamp Similar to WIPRO Cat No. WIO921208 Panaonic(Eq model)/Crompton(Eq model)//Halonix(Eq model)/Bajaj(Eq model)/equivalent make. |
460 | Surface mounted outdoor type 40W LED TUBEwith LED Lamp Similar to WIPRO Cat No. LE20-491-XXX-57-G1 Panaonic(Eq model)/Crompton(Eq model)//Halonix(Eq model)/Bajaj(Eq model)/equivalent make. |
461 | Surface mounted indoor type 36W 2"x2" Square LED Luminaire with LED Lamp Similar to WIPRO Cat No. CRCO10S036HP57G2 Panaonic(Eq model)/Crompton(Eq model)//Halonix(Eq model)/Bajaj(Eq model)/equivalent make. |
462 | Surface mounted indoor type 6W ROUND LED Luminaire with LED Lamp Similar to WIPRO Cat No. LD80-350-XXX-60-SM Panaonic(Eq model)/Crompton(Eq model)//Halonix(Eq model)/Bajaj(Eq model)/equivalent make. |
463 | Surface mounted indoor type 12W ROUND LED Luminaire with LED Lamp Similar to WIPRO Cat No. LD80-101-XXX-60-SM Panaonic(Eq model)/Crompton(Eq model)//Halonix(Eq model)/equivalent make. |
464 | Surface mounted indoor type 15W ROUND LED Luminaire with LED Lamp Similar to WIPRO Cat No. LD80-131-XXX-60-SM Panaonic(Eq model)/Crompton(Eq model)//Halonix(Eq model)/Bajaj(Eq model)/equivalent make. |
465 | Surface mounted indoor type 10W BULK HEADLED Luminaire with LED Lamp Similar to WIPRO Cat No. LW07-141-XXX-57-XX Panaonic(Eq model)/Crompton(Eq model)//Halonix(Eq model)/equivalent make. |
466 | Surface mounted indoor type 10W MIRRORLED Luminaire with LED Lamp Similar to WIPRO Cat No. LL20-111-XXX-65NE3 Panaonic(Eq model)/Crompton(Eq model)//Halonix(Eq model)/Bajaj(Eq model)/equivalent make. |
467 | SITC of indoor type LED SKIRTING LIGHT mounted on G.I modular box with face plate & cover of suitable size , Similar to LEGRAND MYRIUS Cat No. 673036 or equivalent. |
468 | Supplying and fixing of Call Bell / Buzzer ISI marked suitable for DC /AC single phase 230 volts complete as required. |
469 | Supply, Installation, Testing and Commissioning of ceiling fan 1200mm sweep, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated single core multiatrand copper conductor etc. as required.(Bjaj/Crompton/Havells/Eq make) |
470 | Supply, Installation, testing and commissioning of exhaust fan of 300 mm sweep 900 rpm in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etcas required. |
471 | Supply, Installation, testing and commissioning of exhaust fan of 150 mm sweep 900 rpm in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etcas required. |
472 | Providing and fixing extra down rod of 50 cm length G.I. pipe 20 mm dia heavy gauge including painting etc as required . ( more than 5 cm lenght shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored |
473 | DATA, TELEPHONE & TELEVISION |
474 | Recessed wiring to telephone pointwithclip in type modular telephone socket (RJ 11) ISI markedmounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge. |
475 | Recessed wiring to television point with clip in type modular television socket ISI markedmounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge. |
476 | Recessed wiring to LAN pointwithclip in type modular lan socket (RJ45) ISI markedmounted on G.I modular box with face plate & cover of suitable size , including all accesories and connection as per direction of Engineer in Charge. |
477 | Supplying and fixing of 16 / 18 SWG metal box of 200 mm x 150 mm x 60 mm deepon surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required. |
478 | Supplying and fixing of 25mm PVC conduit along with accessories in recessed wiring including cutting the wall and making good the same in case of recessed conduit as required. |
479 | Supplying and drawing one pair, 0.5 sq.mm FR PVC insulated coper conductor, unarmoured telephone cable in existing surface / recessedPVC conduit as required. |
480 | Supply and drawing of TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated shielded with fine tined copper braid & protected with FR PVC sheath inexisting surface / recessed STEEL / PVC conduit as required. |
481 | Supplying and drawing UTP 4 pairLAN cat-6 cable in the existing surface / recessed PVC conduit as required. |
482 | Supply & Fixing of 9U Rack single section glass door with cable manager, fan & AC Distribution.Complete as required .(Make-VALRACK, VEROPRESIDENT, HCL) |
483 | Supplying, Installing, Testing & commissioning of 24 port distribution data managed 2 layer giga switch suitable for rack mounting. CISCO |
484 | Supplying,Installing, Testing & commissioning of 24 port patch panel suitable for rack mounting D-LINK/HP/3Com or Equivalent. |
485 | Supply and fixing of 10 pair telephone tag box with KRONE terminal |
486 | EXTERNAL LIGHTING |
487 | 7M long G.I.octagonal pole complete with RCC foundation, required G.I base plate , single-arm of ERW galvanised pipe 30mm - 1M length,providingGI pipes for cable entry junction box with prewired 6 Amp SP MCB, loop-in -loop-out , terminal block, wiring with copper wire upto the fitting etc. complete |
488 | 4M long G.I.octagonal pole complete with RCC foundation, required G.I base plate , Single-arm of ERW galvanised pipe 30mm - 1M length,providingGI pipes for cable entry junction box with prewired 6 Amp SP MCB, loop-in -loop-out , terminal block, wiring with copper wire upto the fitting etc. complete |
489 | Supply , fixing& termination of OutdoorStreet Light LEDLuminaire with 72w LED Lamp similar to WIPRO Cat No.LR02-781-XXX-57-G2 / JAQUAR / Philips / Halonix / Panasonic or equivalent. |
490 | Supply , fixing& termination of OutdoorStreet Light LEDLuminaire with 40w LED Lamp similar to WIPRO Cat No.LR02-451-XXX-57-G1or equivalent. |
491 | Supply &fixing ofBUSH LIGHTsuitable for LED lamp Equiv. to WIPRO LF05-600-036-27-XX . With Junction Box. |
492 | Recessed wiring to submain in 2 x 2.5 sq.mm FR PVC insulated single core multistrand copper conductor of ISI marked confirming to IS-694/1990 in 20 mm dia non-metalic heavy duty PVC conduit 1.6 mm thick along with 1 x 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire as equired. |
493 | Laying of one number of PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade of 2Cx 6 sq.mm Al.direct in ground in the same trench in one tier horizontal formation including excavation , sand cushining protective covering and refilling the trench etc. as required. |
494 | Supplying and making end termination with brass compression gland and aluminum lugs for 2C x 6 sq.mm of PVC insulated and PVC sheathed / XLPE aluminum cable of 1.1 KV as required. |
495 | Supplying and fixing of 16 / 18 SWG metal box of 200 mm x 150 mm x 60 mm deepon surface / recess with suitable size of phenolic laminated sheet cover in front including cutting the wall and making good the same in case of recessed conduit as required. |
496 | Supplying and fixing ofof 50mm G.I pipe(Medium Class) along with accessories ingroundincluding cutting & making good the sameas required. |
497 | Supply, delivery & installation of GI coil earthing made out of 8 swg GI wire closely wound in shape of a helical coil of 50mm diameter with 115 numbers of turns including excavation of earthpit of size 800x 800x 1500mm in all kinds of soil, back filling the excavated pit with alternate layers of salt, charcoal around the coil with a diameter of 300mm upto 1000mm and balance by good quality soil, end termination complete as required. |
498 | FIRE FIGHTING & FIRE ALARM SYSTEM |
499 | Sub-Head - I - DOWNCOMER. |
500 | Supply, erection, testing and commissioning of following sizes of heavy grade ("C" class) mild steel pipe, flanges and fitting such as bends, tees, reducers, rubber insertions and galvanized nuts and bolts"Heavy class" confirming to IS:1239-1974 Part - I and part - II with upto-date amendment i/c giving two coats of hot bituminous paint. Make- Tata/Zindal/Sail/Eq |
501 | 100mm dia |
502 | 80mm dia |
503 | 25mm dia |
504 | Providing and fixing Single headed, S.S ISI marked oblique patternhydrant landing valvewith80mmdia flangedinlet and 63mm dia instantaneous type female outlet complete withcap and G.I. chain, twist release type plug and all accessories as per 13:5290-1983 (Type "A"). Make-KARTAR, Safex, Fireshield,Safe Guard |
505 | Providing and fixing standard short size gunmetal branch pipe with gunmetal nozzle 16mm dia outlet with standard male instantaneous spring lock type 63mm dia coupling.Branch pipe and nozzle shall confirm to IS : 903-1985. Make-KARTAR, Safex, Fireshield,Safe Guard |
506 | Providing and fixing Non-percolatingflexible canvas hose(RRL type-"A") ISI marked (IS:636) 63 mm dia x 15 M long complete with instantaneoustype gunmetal 63mmdia. IS markedMaleandfemale couplings (IS:903)bound and riveted to hose pipe with copper rivets and 1.5 mm copper wire. Make-KARTAR, Safex, Fireshield,Safe Guard |
507 | Providing and fixing standard fireman"s axe with heavy insulated rubber handle complete. |
508 | Providing and fixing dial type pressure gauge with isolation cock and pipe. Make-H.guru/Emerald/Fiebig/Equivalent |
509 | Dial diameter 100mm calibration 0-15 kg. |
510 | Providing and fixing first aid fire hose reel equipment confirming to IS : 884-1969 with upto date amendments finished with post office red spray paint and complete with following as required :Make-KARTAR, Safex, Fireshield,Safe Guard |
511 | 20mm dia 30metres long hose tubing of approved make confirming to IS : 5132-1969 with upto date amendments. |
512 | Swinging type hose guide fixing bracket assembly |
513 | 6mm outlet gunmetal nozzle with shut off valve as required |
514 | Providing and fixing brass/bronze lever operated ball valves of full flow with stainless steel ball (AISI 304 and spindle AISI 401) with settling and gland of superior quality and having minimum working pressure of 15 Kg/cm2.Make-Kartar/Zoloto/H Sarker/Eq. |
515 | 25NB |
516 | Supply, installation, testing and commissioningof Fire Brigade inlet connection with provision for Four male instantaneous coupling fabricated out of 150 mm dia. approved make heavy class MS pipe with non-return valve, Butterfly valvefor fire fighting system including making connection by providing necessary piping & fittings to the fire storage tank, fire fighting wet riser, sprinkler system painting the same with 3 coats of enamel paint over a coat of Zinc Chromate primer all complete as per drawings, specifications. Make-Minimax, Safex, Fireshield,Kartar. |
517 | a) Three way |
518 | Sub-Head II- Terrace Pump |
519 | Supplying,installation,testingandcommissioningof electric driven terrace pump suitable forautomatic operationandconsistingoffollowing,completeinall respects, as required: (Terrace Pump). Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520. SuitableHPsquirellcageinductionmotorTEFCtype suitable for operation on 415 volts, 3 phase, 50 Hz, AC supplywithIP55classofprotectionforenclosure, horiziontalfootmountedtypewithClass-"F"insulation,conforming to IS-325. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. Suitablecementconcretefoundationdulyplastered and with anti vibration pads. Make-wilo,kirloskar/lubi/equivalent. |
520 | 900 lpm at 35 m Head |
521 | Sitcof Terrace Pump Controller |
522 | Supplying,installation,testingandcommissioningof pump controller.Make-c&s/l&t/crompton/Eq |
523 | Sub-Head IIIFIRE PUMPS & ANCILLARY WORKS |
524 | Providing,installation,testingandcommissioningof cast ironY-strainerfabricatedoutof1.6mm thickstainlesssteel,Grade304,sheetwith3mmdia holes with stainless steel flange.Make-Kartar/Zoloto/H Sarker/Eq. |
525 | 100mm dia |
526 | Providing, fixing, testing & commissioning ofC.I. dual plated Non-return valve [PN 1.6 Rating (16kg/cm2] complete2 nos. matching flanges, rubber insertion, with nuts, bolts and washers etc of following sizes .Make-Kartar/Zoloto/H Sarker/Eq. |
527 | 100 mm dia |
528 | Providing, fixing, testing & commissioning of C.I. Butterfly valve conforming to IS : 13095 with nut, bolts and washers complete . [PN -1.6 rating (16kg/cm2)]Make-Kartar/Zoloto/H Sarker/Eq. |
529 | 100NB |
530 | Supply,Providing & fixing Pressure Switchthe most commonly used fluid control components of Aluminum enclouser with storage temprature 40 to 180°F (-40 to 82°C) along with ambienttemprature 0 to 160°F (-18 to 71°C),set point shifts less than 1% of range for a 50°F (28°C) ambient temperature change. Unit will operate down to -40°F (-40°C) but with reduced repeatability. Maximum media temperature 200°F (93°C), Shock Set point repeats after 50 G, 10 millisecond duration. Switch output One SPDT including seven electrical terminations; Refer to "How to Order" and vibration set point repeats after 10 G, 5-500 CPS.Make-Honeywell/Danfoss/Jhonson controls. |
531 | Sub-Head - IV -Hand Appliances |
532 | Note :All the fire extinguishers shall be ISI marked and filling/validity date shall be painted. |
533 | Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS : 2878 finished externally with red enamel paint and fixed towall with brackets complete with internal charge.Make-Minimax, Safex, Fireshield, Safe Guard |
534 | Capacity 4.5 kg |
535 | Providing and fixing ABC type fire extinguishers consisting of welded M.S cylindrical body, squeeze lever dischange valve fitted with pressure indicating gauge internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to IS finished externally with red enamel paint and fixed towall with brackets complete with internal charge. Make-Minimax, Safex, Fireshield, Safe Guard |
536 | Capacity 6 kg |
537 | Supplying and installing at approved location approved make fire buckets at 24 gauge galvanized stseel sheet, standard 9 liters capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter "FIRE" in black and gold.Cost shall be inclusive of Providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 5 buckets. Make-Agni,/Cease fire/Eq. |
538 | Sub-Head V FIRE DOOR |
539 | Supply, installation, testing and commissioning offire metal door. Pressed Galvanized steel confirming to IS 277 specification.Door frame shall be Double rebate profile of size 139 x 57 mm made out of 1.20mm minimum thick galvanized steel sheet& single leaf door. Provision should be kept for grouting with cement & sand slurry necessary for fire doors on the clear masonry opening. Door leaf should be 43mm thick fully flush double skin door. Door leaf shall be manufactured from 1.0 mmthick galvanised steel sheet single leaf door. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepared for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. painting system will be powder coating finished. Make: Coburn /Garg or Equivalent |
540 | Size : 1250mm x 2250mm(single leaf ) |
541 | Sub-Head VI EXIT SIGNAGES |
542 | supplying,fixing of following type 2 mm thick photo luminecent signages non toxic non radio active maintenance free self glowing safety signages comprising of supplied chargeable crystals to glow in the dark with high intesity luminous 1.2mm aluminium sheet properties by chemical coated ( Vinayal & Tap not accepted) and covered with UV Protection layer printed with graphics symbol etc as required. |
543 | For FIRE EXIT(12"" X 6"") |
544 | For FIRE HYDRANT(16"" X 6"") |
545 | For Lift (12"" X 6"") |
546 | For Stair case (12""x6"") |
547 | Arrows symbol(12""x6"") |
548 | Sub-Head VII FIRE ALARM SYSTEM |
549 | SITC ofMicroprocessor based,Conventional type Fire Alarm Control Panel with 2 nos. of zone.operating voltage 24v dc. Make: Honey well / Agni/ Esser/Eq |
550 | Hooter with Strobe Supply, installation, connecting, testing and commissioning of Conventional Hooters cum strobe min. 95 db output , the cost includes of control module .Make: Honey well / Agni/ Esser/Eq |
551 | Supply, installation, connecting, testing and commissioning of Conventional Manual Call Box in ABS plastic as required complete Pull Down Type. Make: Honey well / Agni/ Esser/Eq |
552 | Looping Cable Supplying, installing, testing and commissioning of Fire Survival armoured cable,Fibre glass tape wrapped, ZH inner, outer sheath 2C X 1.5 sq. mm, PVC insulated copper wires with aluminium armour confirming to IS standards and specifications. Make-Polycab/RR cable/Eq |
553 | HVAC |
554 | Supplyinstalation testing commissioning of HI-WALL TYPE UNIT with OEM manufactured rotary compressor Three Star rated non inverter type with stablizer (R410A/R32- refrigerant)suitable for 230V, 50 Hz, single phase AC. ) & making all arangement for installation i/c factory fabricated bracket, cutting the wall, making good the damages etc. as required(Make:- Daikin ,Hitachi or Eqiv) & making all arangement for installation i/c factory fabricated bracket, cutting the wall, making good the damages etc. as required.with Refrigerant Copper Piping Make-Rajco/Mandev/Maxflow ,PVC drain piping including insulation Kinni foam connectionswithunitswithU-trap, nipple clamps etc. of make-Ashirbad/Astral/Supreme |
555 | 2 TR |
556 | MECHANICAL VENTILATION |
557 | Supply installation, testing , commissioning of SISW Backward curved centrifugal fans (Bearing, motor and shaft shuould be outside of airflow path).Consistng of motor , drive arrangement, MS channel common base frame for fan. Fan should be AMCA certified for AIR, SOUND and FEG( minimum FEG should be 80). Outlet velocity of the fan should not exceed 11 m/s. Shound level of the fan should not exceed 75db(A) @ 3 meter distance. Installed motor Kw. should be 30% higher than fan brake Kw. (Moter make- Havels/ CGL/ BBL/ Hindustan Motors). ( Fan Make-kruger, Nicotra, Greenheck) |
558 | 3900 CFM @25mm static pressure |
559 | 2700 CFM @25mm static pressure |
560 | Supply, installation, balancing and commissioning of Site fabricated Gi sheet metal rectangular ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as per specifications.(As per SMACNA)(Make-TATA, SAIL,Jindal) |
561 | 24 Gauge ( Thickness 0.63mm) |
562 | Supply, Installation, testing and balancing of powder coated Alluminium Grilles complete withnuts, bolts, screws etc. as per drawings and specifications. (Make-Glenstroms, carryaire,System air ) |
563 | Supply air grille withAlluminium volume control damper |
564 | Supply, fixing and commissioning of exhaust air louvers with section comprising of powder coated Aluminium louvers & bird screen as per specifications. (Make-Glenstroms, carryaire,System air ) |
565 | ELECTRICAL WORKS |
566 | Supply, laying, testing and commissioning of following sizes of PVC sheathedXLPEinsulatedAluminiumconductorarmouredcablesof 1100Vgradeonsurfaceofwallorinexistingcabletrays/masonry ducts/ hume pipe with fixing hardware etc. as required. (Make- Polycab, Havels,RR cable ) |
567 | 4 Core x 2.5 Sq.mm |
568 | STARTER PANEL FOR FAN |
569 | Supply, Installation, testing & commisioning of 3 KW 3 phase DOL starer with D range Contactor & LR1D OLR in 2mm CRCA steel sheet duly painted having 1 no 32A 4P MCB, 1 no 3P power contactor, 1 no 9 to 15A PLR, 1 no 30A CT operated ameter, 3 nos. phase indication lamp, 3 nos. ON,OFF,TRIP indicator, 2 nos. ON/OFF push button, 1 no. emergency stop with provision for remote operation for ventilation fan. (Make- L & T, Siemens, Havels) |
570 | CCTV |
571 | SUPPLY AND INSTALLATION 64 CH NVR Up to 12 MP resolution 8 SATA (DS-8664NI-I8 ) Make: HIKVISION or equivalent. |
572 | SUPPLY AND INSTALLATION 32 CH NVR Up to 12 MP resolution 2 SATA (DS-7632NI-K2 ) Make: HIKVISION or equivalent. |
573 | SUPPLY AND INSTALLATION 16 CH NVR Up to 12 MP resolution 2 SATA (DS-7616NI-K2 ) Make: HIKVISION or equivalent. |
574 | SUPPLY AND INSTALLATION 2MP DOME CAMERA (DS-2CD1323G0E-I) Make: HIKVISION or equivalent. |
575 | SUPPLY AND INSTALLATION 2MP BULLET CAMERA (DS-2CD1023G0E-I) Make: HIKVISION or equivalent. |
576 | SUPPLY AND INSTALLATION 16 PORT GIGA POEMake: HIKVISION or equivalent. |
577 | SUPPLY AND INSTALLATION 8+1 PORT GIGA POEMake: HIKVISION or equivalent. |
578 | SUPPLY AND INSTALLATION 4 TB HDD Make: SEAGATE or equivalent. |
579 | SUPPLY AND INSTALLATION 2U RACK WITH FANE PDU Make: NETRACK or equivalent. |
580 | SUPPLY AND INSTALLATION 9U RACK WITH FANE PDU |
581 | SUPPLY AND INSTALLATION UTP 4P CAT 6CABLE(As Per Actual) Make: D-LINK or equivalent. |
582 | SUPPLY AND INSTALLATION UTP 4P CAT 6CABLE(As Per Actual) |
583 | ELEVATOR |
584 | “Testing, Supply, Delivery, Installation & Commissioning with approved materials, labour etc. in all respect complete of02 nos. Passenger Lift from (GF to 5th Floor), 01 no. Passenger cum Stretcher Lift from (GF to 5th Floor),as detailed in specifications and complete in all respect for NEW HOSTEL & MUB BUILDING AT Koraput MEDICAL COLLEGE CAMPUS |
585 | Providing Passenger Lift , |
586 | Supplying, installation, testing and commissioning of 10 passenger (680Kg) lifts having contract speed of 1.25 MPS serving different floors in the lift shaft including 12 months maintenance period as per detailed specifications enclosed (Annexure) and Terms & Conditions mentioned in NIT and as under :- Location – Girls Hostel , Koraput , Odisha. Type – Gear less machine with Machine Room Speed – 1.25 MPS Floors - 6 floors (G+5 floors) Travel – 16.5 meters (approx.) Stops & Opening – 6 Nos at the same side Controller – microprocessor controlled electronically regulated A.C. variable voltage & variable frequency (VVVF) drive using pulse width modulation (PWM) with phase reverse relay. Automatic Rescue Device complete with dry maintenance free battery of maximum 12 AH capacity each with required Nos. Operation : Microprocessor based single automatic push button with Simplex collective selective /without attendant. Power - 415 Volts, 3 phase, 50 Hz, 4 wires system A.C. Type of Doors- Horizontal Sliding – Centre Opening |
587 | Car – 800mm clear opening with power operated fully automatic centre opening horizontal sliding, Stainless steel scratch proof 1.5 mm thick moon rock finish body work stainless steel drop ceiling and CFL/ LED lamps for lighting inside the car and fan. PVC 3mm thick (minimum) flooring. Landing Doors- Automatic and multi beam full height infra red detector automatic centre opening horizontal sliding 1.5 mm thick stain less steel scratch proof moon rock finish. Fire rating -120 min. Stainless steel hand rail not less 600 mm long at 900mm above floor level to be fixed. Brail system including all facilities for physically challenged persons. Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the elevator, complete with Automatic operated control panel and signals, lift car, car safety devices as per IS: 14665, and as per attached detailed specifications and additional conditions i/c provision for temporary scaffoldings and all minor building works |
588 | Original manufacturer among the approved makes i.e. JOHNSON/OTIS/KONE/SCHINDLER/MITSUBISHI/eq make |
589 | Supplying, installation, testing and commissioning of 15 passenger-cum-stretcher (1020Kg) lifts having contract speed of 1.25 MPS serving different floors in the lift shaft including 12 months maintenance period as per detailed specifications enclosed (Annexure) and Terms & Conditions mentioned in NIT and as under :- Location – Girls Hostel , Koraput , Odisha. Type – Gear less machine with Machine Room Speed – 1.25 MPS Floors - 6 floors (G+5 floors) Travel – 16.5 meters (approx.) Stops & Opening – 6 Nos at the same side. Controller – microprocessor controlled electronically regulated A.C. variable voltage & variable frequency (VVVF) drive using pulse width modulation (PWM) with phase reverse relay. Automatic Rescue Device complete with dry maintenance free battery of maximum 12 AH capacity each with required Nos. Operation : Microprocessor based single automatic push button with Simplex collective selective /without attendant. Power - 415 Volts, 3 phase, 50 Hz, 4 wires system A.C. Type of Doors- Horizontal Sliding – Centre Opening |
590 | Car – 900mm clear opening with power operated fully automatic centre opening horizontal sliding, Stainless steel scratch proof 1.5 mm thick moon rock finish body work stainless steel drop ceiling and CFL/ LED lamps for lighting inside the car and fan. PVC 3mm thick (minimum) flooring. Landing Doors- Automatic and multi beam full height infra red detector automatic centre opening horizontal sliding 1.5 mm thick stain less steel scratch proof moon rock finish. Fire rating -120 min. Stainless steel hand rail not less 600 mm long at 900mm above floor level to be fixed. Brail system including all facilities for physically challenged persons. Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the elevator, complete with Automatic operated control panel and signals, lift car, car safety devices as per IS: 14665, and as per attached detailed specifications and additional conditions i/c provision for temporary scaffoldings and all minor building works. |
591 | Original manufacturer among the approved makes i.e. JOHNSON/OTIS/KONE/SCHINDLER/MITSUBISHI/eq make |
592 | P.H. WORK Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor C-PVC pipesconforming topipe fittings of the following nominal bore with clamps including making good the wall, ceilingand floor all complete as per specification and direction of the Engineer in charge |
593 | GroundFloor |
594 | 20mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
595 | 25mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
596 | 32mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
597 | 40mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
598 | 50mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
599 | In 1st Floor |
600 | 20mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
601 | 25mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
602 | 32mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
603 | 40mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
604 | 50mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
605 | In 2nd Floor |
606 | 20mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
607 | 25mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
608 | 32mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
609 | 40mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
610 | 50mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
611 | In 3rd Floor |
612 | 20mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
613 | 25mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
614 | 32mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
615 | 40mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
616 | 50mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
617 | In 4th Floor |
618 | 20mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
619 | 25mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
620 | 32mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
621 | 40mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
622 | 50mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
623 | In 5th Floor |
624 | 20mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
625 | 25mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
626 | 32mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
627 | 40mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
628 | 50mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
629 | In 6th Floor |
630 | 40mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
631 | 50mm dia C-PVC pipe (Ashirbad/Supreme/Truflow) |
632 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge. |
633 | 250mmthick wall in Ground floor |
634 | In 1st Floor |
635 | In 2nd Floor |
636 | In 3rd Floor |
637 | In 4th Floor |
638 | In 5th Floor |
639 | Supplying all materials, labour, T&Pand cutting hole in R.C.C floors, roofs, etc upto 19 cm thickfor passing G.I. Pipes / P.V.C pipes and fittings etc and repairing the holes afterinsertion of pipes etc with cement concrete (1:2:4 ) including finishing complete so as to make it leak proof as per direction of theEngineer in charge. in Ground Floor |
640 | In 1st Floor |
641 | In 2nd Floor |
642 | In 3rd Floor |
643 | In 4th Floor |
644 | In 5th Floor |
645 | Supplying allmaterials, labour, T&P and cutting grooves in pucca floors and walls for takingGI/ PVC pipes and making good the damages as per the direction of the Engineer in charge. In Ground Floor |
646 | In 1st Floor |
647 | In 2ndfloor |
648 | In 3rd Floor |
649 | In 4th Floor |
650 | In 5th Floor |
651 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all completeas per PH specification and direction of the Engineer in charge |
652 | 250mm to 375mmthick wall |
653 | in Ground Floor to 5th Floor |
654 | Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge |
655 | 15mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make) |
656 | 15mm dia CP angle stop cock (Con-CHR-053KN Jaquar make) |
657 | 15mm dia CPBib cock (Con-CHR-047KN Jaquar make) |
658 | 20mm dia CP consealed stop cock(Con-CHR-083KN Jaquar make) |
659 | 15mm dia CP two in one bib cock (Con-CHR-041KN Jaquar make) |
660 | 15mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make) |
661 | 15mm dia CP extension piece |
662 | 15mm dia CP Pillar cock (Con-CHR-011KN Jaquar make) |
663 | 25mm dia G.M or Brass F.W valve (Sakti make) |
664 | 40mm dia G.M or Brass F.W valve (Sakti make) |
665 | 125mm dia CP gratings |
666 | 15mm CP revolving shower (Jaquar)CON-CHR-209KN |
667 | 50mm dia G.M or Brass F.W valve (Sakti make) |
668 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No. 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricantby non-heat application method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge |
669 | 110mm dia U-PVC SWR pipes(Supreme/Ashirvad) |
670 | 110mm U-PVC door bend |
671 | 110mm U-PVC door Tee |
672 | 110mm U-PVC plain Tee |
673 | 110mm U-PVC plain Y |
674 | 110mm dia U-PVC offset without ear |
675 | 110mm U-PVC plain bend |
676 | 110mm U-PVC vent cowl |
677 | 110mm dia U-PVC "P" trap |
678 | 110mm dia suitable PVC clamp |
679 | Supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge |
680 | 10 litres PVC L.L. Cistern (Slimline-white) |
681 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan conforming to IS:2556-part-3-2004) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x 30mm footrest, fixing 100mm dia HCI ‘P’ or ‘S’ trap (with/without 50mm dia horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge(Nycer,parryware make) |
682 | 580mm size Orissa pan(Hindware/Parryware/Jauar) |
683 | Supplying all materials, labour, T&P and fixing glazed earthenware squatting plate of size 600mmx350mm with integral longitudinal flushing pipe including embedding the plate in 25mm cement mortar (1:8) laid over 150mm cement concrete (1:5:10) using 40mm hard granite metal all complete as per specification and direction of the Engineer in charge |
684 | Fixing of squatting urinal (Parryware/Hindware/Jauar) |
685 | Supplying all materials, labour, T&P and fixing Wash Down Water Closet (European type W.C pan) with integral ‘S’ or ‘P’ trap to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification and direction of the Engineer in charge. |
686 | E.W.C. with seat cover (Parryware/Hindware/Jauar) |
687 | EWC(Matrix set)No.70002(P-18) |
688 | Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps conforming to IS:2556-part-4-2004 with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore(Plaza make), fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste(Plaza make),etc all complete as per specification and direction of the Engineer in charge |
689 | 550mm x 400mm size W. H. Basin with Porcelain Pedestal (Parryware/Hindware/Jauar) |
690 | Under Counterbasin(560x450)Hindware-No.10095 |
691 | Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge |
692 | 600mm x 450mm size B.E mirror |
693 | Large size mirror with frame(75x0.60x0.90)=40.50 |
694 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
695 | 600 x 125mm plate glass shelf with CP guard rails(Jaquar)AKP-CHR-35771P |
696 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
697 | 25mm x 600mm long CP towel rail(Jaquar)ACN-ACR-1111N |
698 | CP towel Ring(Jaquar)ACN-ACR-1121N |
699 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge |
700 | CP soap holder (Jaquar)ACN-ACR-1131N |
701 | Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste, fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge |
702 | 600 x 450 x 250mm size S/S kitchen sink (Jayana make ) |
703 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard granite chips broken including watering, curing, conveyance of all materials to worksite, payment of royality, taxes etc all complete as aper specification and direction of the E.I.C In 1st Floor |
704 | In 2nd Floor |
705 | In 3rd Floor |
706 | In 4th. Floor |
707 | In 5th. Floor |
708 | Supplying all materials, labour, T&P and providing cement flush pointing with C.M (1:3) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
709 | In Ist Floor |
710 | In 2nd Floor |
711 | In 3rd Floor |
712 | In 4th Floor |
713 | In 5th Floor |
714 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including cement punning,watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
715 | In Ist Floor |
716 | In 2nd Floor |
717 | In 3rd Floor |
718 | In 4th Floor |
719 | In 5th Floor |
720 | Supplying the waterproofing material Pidifin 2K of Dr.fixit on equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1"-6" in wall including cleaning,applying and mending as per specification including all labour charges as per direction of Engineer-in-charge. |
721 | In Ist Floor |
722 | In 2nd Floor |
723 | In 3rd Floor |
724 | In 4th Floor |
725 | In 5th Floor |
726 | Supplying all materials, labour, T&P and providing and filling cynder including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
727 | In Ist Floor |
728 | In 2nd Floor |
729 | In 3rd Floor |
730 | In 4th. Floor |
731 | In 5th. Floor |
732 | Supplying all materials, labour, T&P and providing Ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles etc complete as per direction of the Engineer in charge. (vitrified tiles of size300x300 of make- Kajaria/Somany/Johnson/Orient Bell/Rakplain/printed series to be pre-approved by the Engineer in charge)In 1st Floor (Kajaria-Fogparla or equivalent make) |
733 | In 2nd Floor |
734 | In 3rd Floor |
735 | In 4th Floor |
736 | In 5th Floor |
737 | Supplying all materials, labaour, T&P and fixing ceramicglazed tiles in dados skirting on 12mm thick cement plaster (1:3) joined with neat cement slurry mixed ith pigments to match the shades of the tiles etc. complete as per direction of the Engineer-in-charge.(ceramic vitrified Glazed tiles in wall of size 450x300 ) of makeKajaria/Somany/Johnson/Orient Bell/Rak) plain/printed series to be pre-approved by the Engineer-in-charge. in Ground Floor(Kajaria-Durenmarfil or equivalent make) |
738 | In Ist Floor |
739 | In 2nd Floor |
740 | In 3rd Floor |
741 | In 4th Floor |
742 | In 5th Floor |
743 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finishstructural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material,The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre"s standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
744 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigmentscomplete in all respect as per specification and direction of the Engineer in charge |
745 | Finishing wall surface of walls with providing two coats wall putty (Water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc complete. |
746 | In Ist Floor |
747 | In 2nd Floor |
748 | In 3rd Floor |
749 | In 4th Floor |
750 | In 5th Floor |
751 | Supplying all materials, labour, T&P and distempering two coats to walls with distemper of approved shade on new work to give an even shade etc all complete as per specification and direction of the Engineer in charge |
752 | In Ist Floor |
753 | In 2nd Floor |
754 | In 3rd Floor |
755 | In 4th Floor |
756 | In 5th Floor |
757 | Supplying all materials, labour, T&P and constructing Gully Trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, Fly ash brickwork in c.m (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat ofneat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size C.I grating etc all complete as per approved drawing, specification and direction of the Engineer in charge |
758 | Supplying all materials, labour, T&P and constructing Inspection Chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6),moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
759 | Inside size 760mm x 760mm x 460mm |
760 | Fitting and fixing RCPC cover slab (0.45m dia) |
761 | Supplying all materials, labour, T&P and providing kodappa slab in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge |
762 | Supplying all materials, labour, T&P and providing granite tiles in slab, treads and landing on 20mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles etc all complete as per direction of the Engineer in charge |
763 | Construction of 40000 Liters RCC Over head Tankin sixth floor with RCC Stagging(Domestic & Fire fighting) |
764 | Supplying all materials, labour,T&P and providing cement concrete (1:1.5:3) for RCC work using 12mm HG chips including hoisting,laying,curring and conveyance of all materials to site etc complete. |
765 | Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gauge.in 6th Floor. |
766 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in 6th Floor. |
767 | RCC floor roof, chajja etc |
768 | RCC Beam, Column, wall etc |
769 | Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) overCC workincluding watering curring and conveyance of all materialsto site. |
770 | Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site. |
771 | Providing fitting and fixing stainless steel ladder including fixing to wall necessary welding etc. complete |
772 | Providing fitting and fixing MS cover made out of MS angle and sheet duly welding and fixing with frame and hinges along with locking arrangement of size 60cmx60cm etc complete as per direction of Engineer-in-charge |
773 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS UV of size 750x570x1350mm height with water storage capacity 120 liters along with 3 nos of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all completeas per approved drawing,specification and direction of the Engineer in charge. |
774 | Aquagurd Pure Chill 120 PSS UV |
775 | Sinking of 200mmx150mm dia Bore Well through DTH method.- 2 Nos. |
776 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation(G.I/P.V.C/M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only |
777 | Drilling of 200mm dia bore0 to 30 mtr |
778 | Drilling of 200mm dia bore31 to 45 mtr |
779 | Drilling of 150mm dia bore41 to 125 mtr |
780 | Labour for lowering the following size of PVC casing pipes with or without slotted pipes as per necessity from ground level upto 300 mtrs depth and fitted and set up in perfectly vertical position including cutting and threading of blank pipes and slotted pipes and supplyinging and fixing of all jointing materials ,extra sockets and T&P etc. all complete and keeping the top of casing pipe threaded including plugging the tubewell to prevent entry of foreign materials |
781 | Lowering of 200mm dia PVC casing pipes 0 mtr to 30 mtrs |
782 | Lowering of 200mm dia PVC casing pipes 31 mtr to 45 mtrs |
783 | Cost of 200mm dia PVC schedule - 80 pipe |
784 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge |
785 | Supplying all materials,labour,T&P andproviding around sealing by cement concrete grouting of annualr space around GI/PVC housing pipe upto 5 mtr below ground level ( as per drawing ) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer-in-charge . Mimimum one meter of casing pipe to nserted in the bore in to the rock the bottom to ensure sanitary sealing ( excluding cost of cement which willbe supplied by the Department ) |
786 | Sanitary sealing upto 5 mtr below ground level |
787 | CC(1:2:4) with 12mm chips for grouting up to 5 mtr Depth in |
788 | 1x5x3.14x(0.15-0.10) |
789 | Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing,commissioning,trial running,conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge. |
790 | 2HP Three Phase 3 stage submersible pump set. |
791 | DOL control panel |
792 | 50mm S. S. Nipple, S. S. bolt & clips |
793 | 50mm M. S. Clamp, Bend, Socket & 200mm M. S. well cap |
794 | 2.50mm Sqm Submersible flat cable |
795 | Steel rope with cover |
796 | 20mm dia rigid U-PVC pipe |
797 | 50mm dia HDPE pipe |
798 | Labour charges for lowering, testing, commissioning & transportation to site etc. |
799 | Supply all materials, labour, T&P and providing, fitting and fixing of centrifugal pump set to run on 3phase/1phase line voltage ranging from 320 volt to 450 volt with suitable control pannel, jointing with GI/ PVC/ HDPE pipes electrification, testing,commissioning,trial running,conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge. |
800 | 5 HP 3 phaseHorizontal submerssiblepump set. |
801 | DOL control panel |
802 | Labour charges for lowering, testing, commissioning & transportation to site etc. |
803 | Supplying all materials, labour, T&P and providing and laying in trenches PVC ASTM pipeof the following nominal bore, tube fittings, testing all complete as per specification and direction of the Engineer in charge |
804 | 50mm dia PVC ASTM |
805 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor CPVC pipesof the following nominal bore and pipe fittings with clamps including making good the wall and testing as per specification and direction of the Engineer in charge |
806 | 50mm dia CPVCpipe (sch-80) |
807 | Earth work in all kinds of soil within 50 mtr initial lead and 1.5mtr initial lift includingrough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3 mtr in depth and as per direction of the Engineer in charge. |
808 | 100m x 0.45m x 0.60m =27.00 |
809 | Supplying all materials, labour T&P and fitting and fixing brass/CP/PVC fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer in charge. |
810 | 50mm dia Brass N. R. Valve |
811 | 50mm dia Brass Check Valve |
812 | 50mm dia Brass F. W. Valve |
813 | Supplying all materials, labour, T&P and construction of Fullway valve chamber/Stop cock chamber of the following inside size for fullway valve with cement concrete slab (1:2:4) mix , 7.50cm thick, foundation concrete (1:5:10) and inside plastering with cement mortar (1:3) finished with a floating coat of neat cement including curing etc all complete as per approved specification and direction of the Engineer in charge |
814 | Inside size 250mm x 250mm x 560mm |
815 | Supplying all materials, labour, T&P and constructionman hole chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1½:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
816 | Inside size 910mm x 910mm x 910mm |
817 | Addl depth |
818 | Fitting and fixing RCPC cover slab (0.45m dia) |
819 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class K.B brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
820 | 1.40m dia x 2.00m deep |
821 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasingincluding concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. |
822 | 110mm dia u-pvc pipe alround concrete |
823 | 160mm dia u-pvc pipe alround concrete |
824 | 200mm dia u-pvc pipe alround concrete |
825 | Supplying all materials, labour, T&P and constructing circular type man hole chamber of the following sizewith cement concrete (1:4:8) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar (1:5), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, 12mm thick cement plaster (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
826 | Circular MH inside dia 1200mmx1670mm with sides sloped upto560mm |
827 | Cost of RCPC Cover |
828 | Construction of 50 KLDSTP Civil Works |
829 | Earth work in excavation of foundation in all kinds of soil within 50 mtr initial lead and 1.5mtr initial lift includingrough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3 mtr in depth and as per direction of the Engineer in charge. |
830 | -do- with Ist additional depth of 1.50 m over the initial lead and lift |
831 | Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer incharge. |
832 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
833 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
834 | R.C.C. work of M-30 grade with 20mm and down grade black hard black crusher broken granite stone chips of approved quality from approved quarry including hoisting, lowering, laying and compacting concrete, watering curing, centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,labour cess and T & P required for the work etc. complete in all respect but excluding the cost and conveyance of M.S. rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position and as per spection and the direction of the Engineer-in-charge. |
835 | Base slab |
836 | Wall |
837 | Roof Slab |
838 | RCC Lintle |
839 | Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage. |
840 | Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) overCC workincluding watering curring and conveyance of all materialsto site. |
841 | Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site. |
842 | Quantity same as itemabove inside |
843 | Supplying and fitting and fixing stainless steel 304 grade in said rail using 5mm dia 2mm thick circular pipe and balustrade 32mmx32mmx2mm at the rate of mtr.Center to center and square pipe 32x32x2mm below doors and windows with ss platevincluding welding with stanless steel elect rod and fixing with necessary accessories etc.complete as per direction of the Engineer-in-charge. |
844 | Providing fitting and fixing RCPCcoveretc complete as per direction of Engineer-in-charge |
845 | Supplying all materials, labour, T&P and providing brick work using fly ash bricks in CM(1:6) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
846 | Supplying all materials, labour, T&P and providing 16mm thick cement plaster in CM(1:6) over brick work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
847 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster in CM(1:4) over brick work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
848 | Supplying all materials, labour, T&P and providing two coats of plastic paint over a coat of primer of approved shade, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
849 | Quantity same as itemabove inside |
850 | Supplying all materials, labour, T&P and providing two coats of weather coat over a coat of primer of approved shade, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
851 | Quantity same as itemabove 231 |
852 | Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, all materials, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. |
853 | Quantity same as itemabove inside |
854 | Electro Mechanical portion of 50 KLD STP |
855 | Supplying, Installation, testing & commissiongof Packeged type Prefabricated (MS with 3mmFRP coating with anti-corrosivecoating Modular STP Capacity of 50 KLD on FMR (Fludised Media Reactor) / FAB (Fludised Aerobic BioReactor) technology with Lamella/Tube Settler andproviding all equipment, piping etc.at site including erection testing & commisioning of equipments, electricals, piping for Sewage Treatment Plant (Make - ION Exchange (India) Ltd.) |
856 | The RawSewage shall be domestic Sewage and the qualityof treated sawage shall be as under: BOD : Shall not be more than COD : Shall not be more than TSS : Shall not be more than Oil and grease : Shall not be more than 10 mg/litre The STP shall be covered following |
857 | MS bar Screen : Supplying , installing , testing and commissioning of 1No.barscreenintheexistingcivilstructureinfrontoftheintake works , so as to exclude the large sized particleswith associated set ofguide anglesinMSflatof10.00mmscreenkeptinclinedat45 degreetothehorizontalat40mmc/cwithoneno.handrackinGI. (Necessarycorrection/modificationrequiredtobedoneinexisting civilstructureshallbedonebythecontractorathisowncost).Bar rackshallbefabricatedfromSS-304barstocoverthewidthofthe screen chamber with a racking arm for manual operation. Size: 10 mm |
858 | RawSewagePumps: Supplying, installing, testing and commissioning of 02 Nos (1W + 1S) centrifugal, Non - Submersible type raw sewage water pumps with a solid handling capacity of 40 mm to pump sewage from equalisationsumptoaerationtankatuniformflowrate.Thepump shall be three phase, three HP electrical motor mounted on a common base frame each of these pumps shell also include. (Make : Jhonson / Kriloskar / equi. ) |
859 | a). Dry run protection. b) 1 No.Pressure gauge 4" dial with valve tee and fittings. c) 2nos.castironleveropertedslimsealtypebutterfly valvesofCI bodyandspheroidalgraphiteirondisc(SGiron),withnitrilerubber seal , tested to 10 kg / sq. cm Confrming to BS 5155 / MF6 standards andincludingasetofGIflangesasper BS-10table1includingbolt nuts,GIwashers,andneoprenerubbergasketsCompleteetc.( Make: Crane / Intervalve / Audco ) on the delivery side. |
860 | d) 2Nos. Slimsealflap typecheck valvewith CI body andcast steel disc pressure rating PN-10 kg/ sq. cm including a set of GI flanges as perBS-10table1includingboltnuts,GIwashers,andneoprene rubbergasketscompleteetc., (Make: Expert / Intervalve / Audco )onthe delivery side. e) GI manifold finished neatly with hot dip galvanizing to 100 microns withflangedendoneithersidesandcollarprovisionforconnectivity of above mentioned valves. Thesepumpsshallbesuitableforthefollowingrequirements:Flow rate = 2.5 cum/hr., Head 10 meter. |
861 | PRE-FABRICATED STP |
862 | a) SEWAGE TREATMENT PLANT (STP) - MS TANK with 3mmthick FRPcoating inside with Akzo Noblecoatingonbothsides ofSewagetreatmentplant, having an inbuilt Aeration-I& Aeration-II,Lamella/Tubesettlingtank,chlorinecontacttankwith laddersprovisiononeachplantandrailingetc.,havingmin.sizeof (L x B x H)4.0mx 2.13 mx2.2m,minimunvolumeofreactor should be19CuMtr.orasperapprovedOEM"sdesignandcapacitybut shouldhaveminimumretentiontimeof6hours,Minimumthickness of MS sheet should be 5 mm with special anti corrosive coating. |
863 | Following shall also be provided in Sewage Treatment Plant. |
864 | b) Air Diffusuion system forSTP aeration chamer I&II:Supplying installing,testingandcommissioningof06Nos.airdiffusersof varyingsizesconsistingoffinebubblediffuser alongwithmembrane fromEDI, USAshallconsistsofsetofEPDMmembranes,SS304 clips,PVC support pipe(10kscpressure rating),PVCfitting,nylon ropebraidedhosewithallaccessoriestomakeitretrievable&to provide cloq- free oxigen for Aeration tanks. |
865 | c) MBBR ( Moving Bed Bio Film Reactor) / FMR ( Fluidized Media Reactor) Media : Supplying, installing, testing and commissioning of 1.5 cum MBBR/FMR Media. |
866 | d)LAMELLACLARIFIERMECHANISM : Supplying, installing, testing and commissioning of one set of lamella/tube settler clarifier mechanism to fit into clarifier tank which consists of inclined overlapping FRP plates which will be arranged to form a separate dimentation chamber or the cells between each pair of adjacent plates. The overlapping additive projected area of several plates will be a factor of increasing surface settling area proportion to the number of plates used. |
867 | The inlet flow will divide and enter the tower part of each sedimentation cell from its two opposite sides. As the water will displace upward in smooth, gently, flow, the suspended solids coalesce to from precipitates which will settle in the chambers on the lower portion of each lamella plate. Influent water flows upwards over the plates. The deposited precipitates increase in size until they slide or roll down the inclined surface of the plates. This will then be collected in the hopper provided at the bottom of the separator. |
868 | Air Diffusion System for EQ ( Equalization ) tank& SHT( Sludge HoldingTank) : Supplying, installingandcommisioning of Air Grid of varying sizes as per manufacurers specifications with PVC flexible hose HDPE pipegrid (or) as per OEM manufacturers design to provide clog - free oxygen for Equalisation Tank & Sludge Holding Tank. |
869 | AirBlowers:Supplying, installing, testing and commissioning of TwinLobe designtype02 Nos (1W + 1S)airblowercompletewithmotors, pulleys,RigidonepieceCIcasingandsideplates,silencer,base plate,anti-frictionbearings,Rotaryoilsealingshavinghorizontal configuration |
870 | a)TwinLoberoot typeAir blower of75 m3/hrat 0.37kg/sqcm capacitycomprisingofcommonbaseframe,suctionsilencer,non, return,Vbelt,safetyvalve,beltguard,driveanddrivenpulleys, pressuregauge,interconnectionpiping, dischargesilencer,anti vibration pads including required motor of 3.0 HP, 1500 rpm, IE-2 efficiency with IP-55 protection |
871 | b) 2 Nos. cast iron lever operated slim seal type butterfly valves of CI bodyandspheroidalgraphiteirondisc(SGiron),withnitrilerubber seal,testedto10kg/sq.cmconformingtoBS5155/MF6standards andincludingasetofGIflangesasper BS-10table1includingbolt nuts, GI washers, and neoprene rubber gaskets complete etc. ( Make: Crane / Intervalve / Audco / Kitz / Zoloto / equivalent )on the delivery side. |
872 | c) 1 No. pressure gauge 4"dial with valve tee and fittings. |
873 | ChlorineDoser:Supplying, installation, testingand commissioning of on line electronic sodium hypo dosing unit with automatically operated dosing pump, etc., Theunitshallcompriseof the following. |
874 | One No. Single moulded FRP cylindrical type chemicalsolution tank of 100 litres capacity having detachablelidswith moulded inserts for mounting of pumps and starter. |
875 | OneNo.Electronicdiaphragmtypepositivedisplacementpump,for chemicaldosingwithplastic head.Theelectronicpumpshallbe operatedon220Vsinglephasesupply andshallbemounteddirecty on the tank top. ( Make: Milton Roy / Asia LMI ) |
876 | Completesetofpipes,valvesandfittings,footvalvemagneticfloat switch to trip the dosing pump at low level of chemical in the tank. |
877 | Thefreechlorinecontentinthefilteredwatershallnotbelessthan 0.5 PPM.Shall consists of one no. 100 Ltrs., HDPE / LLDPE tank with one no. PP, diaphragm type pump of capacity: 0 - 4 LPH shall be provided. |
878 | The pump shall be suitable for the following requirements: Min. Actuating Pressure - 0.3 kg /sq cm; Max., working pressure - 2.5 kg/sq cm; Max., Temperature - 50 deg C; HP - 1/2 and Dosing flow range - 0 4 LPH |
879 | Multigrade Filter: supplying, installation, testing and commissiong of multigrade sand pressure filter for litration of treatedsewage water. The filter shall be designed for a specific velocity of 4 m3/hr/sq.m area shall not be less then 16 Inch DIA with Minium HOS 65 Inch. |
880 | The filtration unit shall comply with the following technical requirements: Flow rate - 4 cu.m/ hr Backwashduration - once in 24 hours for 20 min.Filtering Media - Multi grade of Sand / Pebbles: Pressure drop across unit -1.0 kg sq.cm (max) and dia of filter - 16 Inch, HOS - 65 Inch. MOC- FRP, operating pressure: 3.5 kg per sq. cm |
881 | Further the filtration unit shall comprise the following: |
882 | Thefiltershallbefittedwithinletdistributionandbottomcollecting system. Orifice board/ Rotameter for monitoring back wash flow to be fitted. Initial charge of underbed and carbon fotlering media as required. Complete set of valves, perssure gauge with needle valve and frontal pipe work done with Gray PVC pipes. |
883 | ACTIVATEDCARBONFILTER(ACF):Supply, installation, testing and commissioning of activated carbon filter for filtration and removal of colour in treated sewage water. The filter shall be for 4 m3/hr flow rate and designed to operate for 12 hours. |
884 | TheACFshallbedesignedforaspecificvelocityof4 m3/hr/sq.m area and the approx. dia shall not be less than 16 Inch DIA with 65 Inch HOS ( Height on straight ) of vessel. |
885 | Further the filtration unit shall comprise the following: |
886 | Thefiltershallbefittedwithinletdistributionandbottomcollecting system. Orifice board / Rotameter for monitoring back wash flow to be fitted. Initial charge of underbed and carbon filtering media as required. Complete set of valves, pressure gauge with needle valve and frontal pipe work done with Gray PVC pipe. |
887 | FilterFeedPumps :Supply,Installation,testingandcommissioning of 2 Nos (1W + 1S) filter feed pumps, each ofspecifications : Pump Specification : 04 cum / hr; head : 25meter; 1.5/3HP; 2900RPM; inlet/ outlet 1.5"/2" (or) as per the OEM standard. ( Make - Jhonson / Kirloskar / KSB ) |
888 | PlantPiping : Supply, Installation, Testing Commisioning ofpipes & Valves with fittings suchastees, crosses, plugs, sockets, elbows, unions,flanges,sleevepieces, check nutsetcfor the entire STP Plant. |
889 | a)Providing and fixing of MS pipes to I.S. 1239 including all fittings like bends, flanges, valves, etc., ( Make: Jindal / Tata ) |
890 | b) Inter connecting pipe works with valves for air line- Jindal/Eqv |
891 | c) Inter connecting pipe works with valves for water line- PVC/UPVC |
892 | Sewage TransferPumps :Supply,Installation,testingandcommissioning of 2 Nos (1W + 1S) Submersible pumps, each ofspecifications : Pump Specification : 04 cum / hr; head : 10meter; 1.5/3HP; 2900RPM; inlet/ outlet 1.5"/2" (or) as per the OEM standard. ( Make - Jhonson / Kirloskar / KSB ) |
893 | Sludge Re-circulation Pumps :Supply,Installation,testingandcommissioning of 2 Nos (1W + 1S) Re-circulation pumps, each ofspecifications : Pump Specification : 04 cum / hr; head : 25meter; 1.5/3HP; 2900RPM; inlet/ outlet 1.5"/2" (or) as per the OEM standard. ( Make - Jhonson / Kirloskar / KSB ) |
894 | Ultra Filtration Feed Pumps Capacity-3m3/Hour, Head-25-30 Meter |
895 | Supplying, installing, testing & commissioning of Ultra Filtration System (UF) of Capacity 50 KLD, electro mechanical system (Excluding Civil construction) |
896 | Electrical Panel Works: |
897 | a) Supplying ,installaing ,testing and commissioning of Electrical panelsconsistingofMCCpanel(motorcontrolcenter)to accommodate all the drive units with cabling , glanding within the STP Compartmental,designIndoorwallmountedtypewithtopentryfor cabletheinternalcomponentseitherSiemen/ ABB Shallbeprovided with 1 no. Energy meter. |
898 | To receive , control and distribute electrical power at440 V, 50Hz , ACinasheetsteelhouse.MCCistobemanufactured/assembled asperthelatestISIspecification,IndianElectricityRules,Including specialrequirementsofconcernedstateelectricityinspectorate.The switch board shall be fabricated out of 14 SWG sheet steel and shall be un cubical design.MCC of suitable rating to take care of full load of thesewagetreatmentplantincludingallmotorsandlighting.MCC shall be provided with the following feeders. |
899 | Incoming Feeder : MCCB, Ernergy meter (Voltmeter with selector switch), LED type indication for 3 phases Outgoing Feeder: MCCB Motor feeder, 1 No 3 phase and netural of suitable capacity to be provided Busbar: Aluminium |
900 | b) Power Cables (LT) for use on 415V system shallbeof 1100 volt grade, Aluminium conductor, PVC insulatedas per IS: 1554 (Part I). Motor up to 5 HP copper conductor cable should not be less than 1.5 sq mm of size to be used. |
901 | c) Control Connector, Lugs / Sockets shall be of copper conductor and of Aluminium for conductor cable, suitable, solderless, crimping type. |
902 | d)MCCpanelshouldhavenecessaryfeaturestooperatetheair blowers according to requirement of DO by means of VFD. |
903 | e) Installation and wiring with fixing cable trays. |
904 | Multi Utility Building at Koraput Medical College at Koraput(PH Works) |
905 | Supplying all materials , labour, T&P and providing and fixing to wall or ceiling and floor PVC pipes conforming to C-PVC1785/89 ( Sch-80 ) and G.I pipe fittings of the following nominal bore with clamps including making good the wall,ceiling and floor ,testing all complete as per P.H. specification and direction of Engineer-in-charge . |
906 | In ground floor |
907 | 20mm dia C-PVCPipe |
908 | 25mm dia C-PVCPipe |
909 | 40mm dia C-PVCPipe |
910 | In 1st floor |
911 | 25mm dia C-PVCPipe |
912 | 40mm dia C-PVCPipe |
913 | Supplying all materials,labour,T&P and cutting holes through existing brick work including making good the damages in cement mortar(1:4) for taking GI pipes and fittings/PVC pipes and fittings etc.all complete as per PH specification and direction of the Engineer-in-charge. |
914 | In ground floor |
915 | 250mm thick wall |
916 | Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proofas per P.H. specification and direction of Engineer-in-charge |
917 | In ground floor |
918 | Supplying all materials , labour, T&P and cutting grooves in pucca floors and walls for taking P.V.C pipes and G.I fittings etc. and making good the damagesincluding finishing complete as per P.H. specification and direction of Engineer-in-charge. |
919 | In ground floor |
920 | Supplying all materials , labour, T&P and fitting and fixing brass/CP fittings of following nominal bore with supply of all jointing materialscomplete as per P.H. specification and direction of Engineer-in-charge |
921 | 15mm C.P.Bib cock(CQT-CHR-23037)Jaqquar. |
922 | 15mm C.P.Pillar cock (DRC-CHR-37001)Jaquar. |
923 | 20mm dia CP Concealed Stop cock(FLR-IVC-5083N)Jaquar. |
924 | 15mm dia CP Angle Stop cock.(AQT-CHR-3059) |
925 | 15mm dia CP two way Bib Cock ( KLN-CHR-19041 )Jaquar. |
926 | HEALTH FAUCET1.2 M TUBE(B FLOW PREVNTOR))(ALD-CHR-577)Jaquar. |
927 | 25mm dia brass fullway valve(Shakti Make) |
928 | 40mm dia brass fullway valve(Shakti Make) |
929 | 15mm dia. C.Pextension piece |
930 | 15mm dia. C.P flange |
931 | 125mm dia CP gratting |
932 | Supplying all materials ,labour ,T&P and fixing 10 litres capacity PVC low level flushing cistern with a pair of PVC brackets complete with fittings such as pvc siphonic arrangements, 15mm dia nominal size pvc ball valve with polythene float ,pvchandles, unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet , and connecting the inlet pipe with supply mainetc.all complete as perspecification and direction of Engineer-in-charge |
933 | 10 ltrs. capacity PVC low level cistern (Slimline-white) |
934 | Supplying all materials , labour, T&P and fixing rotational mouldedpolyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr widthKBbrickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 2.60m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxesetc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge.( Sintex/Supreem/Rotomax) |
935 | 2000 ltrs capacity rotational moulded polyethylene cylindrical vertical water storage tank .-In Ist. floor |
936 | Sanitary Installation |
937 | Supplying all materials,labour,T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No.13592/1992 to walls with nails,bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer"s specification,testing,earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of Engineer-in-charge |
938 | 110mm dia U-PVC SWR Pipe (Supreme/Ashirvad) |
939 | 110mm dia U-PVC Door Tee |
940 | 110mm dia U-PVC Plain Band |
941 | 110mm dia U-PVC Plain Tee |
942 | 110mm dia U-PVC Offset without ear |
943 | 110mm dia U-PVC Plain Shoe Bend |
944 | 110mm dia U-PVC Door Bend |
945 | 110mm dia U-PVC "P"Trap |
946 | 110mm dia U-PVC Cowl |
947 | 110mm dia U-PVC Socket plain |
948 | Supplying all materials , labour, T&P and cutting holes through existing brickor laterite masonry wall for takingU-PVC / HCI pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
949 | 250mmto 375mmthick wall |
950 | Supplying all materials, labour, T&P and cutting of R.C.C roof or cornice for taking H.C.I pipes and making good the damages etc all complete as per P.H.Specification and direction of the Engineer in charge. |
951 | Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
952 | Supplying all materials , labour, T&P andfixing Vitreous chinawater closet ,squattingpan ( Indian type W.C. pan / Orissa pattern squatting pan ) duly embedded in cement concrete 1:5:10 using hard granite metal 4cm nominal sizeincluding fixing a pair of vitreous china 250mmx130mmx30mm foot rest, fixing 100mm dia hci "P" or "S" trap for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
953 | 580mmx440mm size Orissa Pan ( White ) |
954 | Supplying all materials,labour,T&P and fitting and fixingvitrous Chaina washed down water Closet (European type water closet - EWC) with integral "P" or "S" type trap to the floor including wodden plug and chromoum plated screw including jointing the trap with soil pipe in CM(1:1) fixing plastic seat cover for washed down water closet with crmium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of Engineer-in-charge. |
955 | European Water Clost "S" trap |
956 | Supplying all materials ,labour ,T&P andfixing Wash basin with hole for pillar taps with cast iron or MS brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. fixing pedestralfor wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered "Hot" and "Cold" with long screws, shanks and back nuts of 15mm dia nominal bore, fixing15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin , fixing 12mm dia CP brass waste etc.all complete as perspecification and direction of Engineer-in-charge. |
957 | 550mmx400mm size wash hand basin with Porcelain pedestal |
958 | Under Counterbasin(560x450)Hindware-No.10095 |
959 | Supplying all materials,labour,T&P and fixing standard sized Glass-shelf with C.P brass bracket and guard rail complete fixed to wooden pluges with screw etc.all complete as per specification and direction of Engineer-in-charge. |
960 | 600mmx125mm glass shelf with CP/NP guard rails |
961 | Supplying all materials ,labour ,T&P andfixing standard sizedCP brass towel rail completewith CPbrass brackets fixed to wooden plugs with chromium plated brass screws etc.all complete as perspecification and direction of Engineer-in-charge |
962 | Fixing 25mmx600mm long CP towel rail25mm x 600mm long CP towel rail(Jaquar)ACN-ACR-1111N |
963 | CP towel Ring(Jaquar)ACN-ACR-1121N |
964 | Supplying all materials ,labour ,T&P andfixing CP Soap Holder complete with CP brass bracketsfixed to wooden plugs with chromium plated brass screws etc.all complete as perspecification and direction of Engineer-in-charge |
965 | CP soap holder (Jaquar)ACN-ACR-1131N |
966 | Supplying all materials, labour, T&P and fixing mirror of superior glass conforming to IS:3438-1996 mounted min 5mm thick on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge |
967 | 600mmx450mm size B.E mirror (fixed type) |
968 | Large size mirror with frame(6x0.60x0.90) |
969 | Supplying all materials, labour, T&P and providing kodappa slab in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge |
970 | Supplying all materials, labour, T&P and providing granite tiles in slab, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles etc all complete as per direction of the Engineer in charge |
971 | Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge |
972 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
973 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
974 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,paymentof royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
975 | Fitting and fixing vetrified tiles with matt finish Kajaria ( Fog Perla or equivalent ) on floor or steps & landing on 25mm. Thick bed of cement mortar (1:1) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including cost conveyance, roylalities and taxes etc. all complete as per direction of Engineer-in-charge.(600mmx600mm) |
976 | Fitting and fixing vetrified tiles with matt finish Kajaria ( Duren Marfil / Equvalant) to dados skirting & risers of steps on 12mm tick C.P(1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including cost conveyance, roylalities and taxes etc. all complete as per direction of Engineer-in-charge. (600mmx300mm) |
977 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finishstructural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material,The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre"s standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
978 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigmentscomplete in all respect as per specification and direction of the Engineer in charge |
979 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS UV of size 750x570x1350mm height with water storage capacity 120 liters along with 3 nos of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all completeas per approved drawing,specification and direction of the Engineer in charge. |
980 | Aquagurd Pure Chill 120 PSS UV |
981 | External S/D portion |
982 | Supplying all materials, labour, T&P and constructing Gully Trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, Fly ash brickwork in c.m (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat ofneat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size C.I grating etc all complete as per approved drawing, specification and direction of the Engineer in charge |
983 | Supplying all materials ,labour ,T&P and constructing Inspection Chamber ofinside size 760mmx760mmx460mmwith cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips,12mm thick cement plaster (1:3)with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxesetc.all complete as perapproved drawing, P.H specification and direction of Engineer-in-charge |
984 | Inside size : 760mmx760mmx460mm |
985 | Supplying all materials ,labour ,T&P and constructing Man Hole Chamber ofinside size 910mmx910mmx910mmwith cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips,12mm thick cement plaster (1:3)with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken black hard granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing, conveyance of all materials to worksite, payment of royalty, taxesetc.all complete as perapproved drawing, P.H specification and direction of Engineer-in-charge |
986 | Inside size : 910mmx910mmx910mm |
987 | Fitting and fixing RCPC cover slab (0.45m dia) |
988 | Supplying all materials, labour, T&P & constructing Soak Way Pit of the following size with dry brick walling from bottom upto invert of inlet pipe andKB brick work in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size crusher broken hard black granite metal on bed, 12mm thick cement plaster in cement mortar (1:4) inside and outside over masonry brick work, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips fitted with iron lifting handles including earth work in open well excavation in all kinds of soil and refilling of cavity around the pit and painting the iron works, watering, curing,cost of all materials,conveyance of all materials to worksite, payment of royalty, all taxes etc. all complete as per approved drawing,PH specification and direction of the Engineer-in- charge. |
989 | 1.80m dia x 2.60m deep inside size Soakway Pit |
990 | Supplying all materials,labour,T&P and laying in trenches ( to level or slope ) unplasticized PVC pipe conforming to IS:4985/2000 of the following outside dia for class-3 (0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/ as per manufactures"s providing and laying in trench cement concrete(1:4:8) with 40 mm size hard granite metal in the Type-C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer-in-charge. |
991 | 110mm dia U-PVC pipe ( Allround concrete ) |
992 | 160mm dia U-PVC pipe ( Allround contrete ) |
993 | Sinking of 200mmx150mm dia Bore Well through DTH method.- 1 Nos. |
994 | Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation(G.I/P.V.C/M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only |
995 | Drilling of 200mm dia bore0 to 30 mtr |
996 | Drilling of 200mm dia bore31 to 45 mtr |
997 | Drilling of 150mm dia bore41 to 125 mtr |
998 | Labour for lowering the following size of PVC casing pipes with or without slotted pipes as per necessity from ground level upto 300 mtrs depth and fitted and set up in perfectly vertical position including cutting and threading of blank pipes and slotted pipes and supplyinging and fixing of all jointing materials ,extra sockets and T&P etc. all complete and keeping the top of casing pipe threaded including plugging the tubewell to prevent entry of foreign materials |
999 | Lowering of 200mm dia PVC casing pipes 0 mtr to 30 mtrs |
1000 | Lowering of 200mm dia PVC casing pipes 31 mtr to 45 mtrs |
1001 | Cost of 200mm dia PVC schedule - 80 pipe |
1002 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge |
1003 | Supplying all materials,labour,T&P andproviding around sealing by cement concrete grouting of annualr space around GI/PVC housing pipe upto 5 mtr below ground level ( as per drawing ) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer-in-charge . Mimimum one meter of casing pipe to nserted in the bore in to the rock the bottom to ensure sanitary sealing ( excluding cost of cement which willbe supplied by the Department ) |
1004 | Sanitary sealing upto 5 mtr below ground level |
1005 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
1006 | 1x5x3.14x(0.15-0.10) |
1007 | Supply all materials, labour, T&P and providing,fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specifications with suitable control pannel, jointing with GI/PVC/HDPE pipes electrification, testing,commissioning,trial running,conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge. |
1008 | 2HP Three Phase 3 stage submersible pump set. |
1009 | DOL control panel |
1010 | 50mm S. S. Nipple, S. S. bolt & clips |
1011 | 50mm M. S. Clamp, Bend, Socket & 200mm M. S. well cap |
1012 | 2.50mm Sqm Submersible flat cable |
1013 | Steel rope with cover |
1014 | 20mm dia rigid U-PVC pipe |
1015 | 50mm dia HDPE pipe |
1016 | Labour charges for lowering, testing, commissioning & transportation to site etc. |
1017 | Instalation of 1.5 HP submerssible pump-motor |
1018 | Supplying all materials, labour, T&P and providing fitting & fixing submerssible pump with squirrel cage induction type submerssible electric motor to run single-phase line voltage ranging from320 to450 volt confirm to IS 8034/89 with following specification suitable control pannel jointing with GI/PVC/HDPE pipe, electrification, testing, commissioning , trial running, conveyance of all materialto work site, payment of all taxces etc all complete as per PH specification and direction of Engineer-in-charge. |
1019 | 1.5 H.P single phase 3 stage head range 20 to 35 metres, discharge 145 to 110L.P.M with outlet dia of 25mm |
1020 | DOL contol pannel suitable for 1.5HP pump |
1021 | 2.50 sqmm flate cable |
1022 | 50mm dia steel short piece |
1023 | 50mm dia C.I Bracket |
1024 | 50mm diaHDPEPipes |
1025 | 25mm dia rigid U-PVC pipe |
1026 | Well cap |
1027 | Steel rope with cover |
1028 | Supplying all materials, labour, T&P and constructingBore well protectionchamber of the inside size 650x650x1000hightwith cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ashbrickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:4)inside and outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. |
1029 | Bore well chamber |
1030 | Construction of 20 users Brick Septic Tank- 1 No. |
1031 | Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of theEngineer-in-Charge. |
1032 | Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general. |
1033 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
1034 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12m size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
1035 | Supplying all materials, labour, T&P and providing brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
1036 | In F&P |
1037 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
1038 | In ground floor |
1039 | Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
1040 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
1041 | R.C.C floor androofslabs |
1042 | Supplying all materials, labour, T&P and providing M.Sreinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
1043 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge. |
1044 | Supplying all materials, labour, T&P and providing,fitting and fixing 100mm x 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification anddirection of the Engineer in charge |
1045 | Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls ofman hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge. |
1046 | Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy