Erection Of 01Nos. 132Kv Transformer Bay For 40Mva Transformer At 132Kv S/S Lalitpur, Under Etd, Jhansi, jhansi-Uttar Pradesh

Uttar Pradesh Power Transmission Corporation Limited-UPPTCL has published Erection Of 01Nos. 132Kv Transformer Bay For 40Mva Transformer At 132Kv S/S Lalitpur, Under Etd, Jhansi. Submission Date for this Tender is 01-02-2023. Clamps Tenders in jhansi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

35726047
Corrigendum : Erection Of 01Nos. 132Kv Transformer Bay For 40Mva Transformer At 132Kv S/S Lalitpur, Under Etd, Jhansi
Open Tender
Indian
Uttar Pradesh
jhansi
01-02-2023

Tender Details

Erection Of 01Nos. 132Kv Transformer Bay For 40Mva Transformer At 132Kv S / S Lalitpur, Under Etd, Jhansi-2 Erection Of Following Different Type Main And Auxiliary Structure, Columns, Beams, Peaks, Masts Ets. Suitable For Placing Of 132 / 33 Kv Equipments. 3 Erection Of Main Structure 4 Erection Of Following Equipments As Per Instruction Manual Of Various Equipments And Technical Specification Including Shifting Of Material / Equipments From Store To Erection Site Including All Other Associated Work To Complete The Job Satisfactorily. 5 Erection Of 145Kv Cb 6 Erection Of 36Kv Vcb 7 Erection Of 145Kv Bus Isolator. 8 Erection Of 145Kv Tandem Isolator. 9 Erection Of Substation Automation System Panel. 10 Erection Of 145Kv Current Transformer. 11 Erection Of 120Kv Lightning Arrester 12 Erection Of 145Kv Post Insulator 13 Erection Of Junction Box For 145Kv Current Transformer. 14 Erection Of Abt Energy Metering Panel With Main And Check Rack. 15 Erection Of 36Kv Current Transformer. 16 Repair / Replacement Work Of 120 Kv Lighting Arrestor. 17 Erection Of 36Kv Bus Iso 18 Erection Of Junction Box For 33Kv Current Transformer. 19 Connection Of The Control & Power Cables As Per New Cable Schedule Of New 40 Mva T / F & Its Oltc / Rtcc Panels At Both Ends Control & Relay Panel, Cooling Fans & Pumps, Marshalling Box Etc. Using Existing Cable, Including Laying Dressing & Binding Of Additional Control Cables, If Required As Per Site Requirement And Termination Alongwith Making Necessary Holes In The Glands Plates Or Box Wherever Required Providing And Fixing Of Cable Glands Of Appropriate Size, Providing Of Ferrules And Cable Termination Lugs As Per Standard & All Other Associated Work As Per Technical Specification Includingpreparation Of Cable Schedule Drawing. 20 Termination 2Cx2.5Sqmm Unarm Ctrl Cable Both End. ( 1500 Mtr. ) 21 Termination 4Cx2.5Sqmm Unarm Ctrl Cable Both End. ( 2000 Mtr. ) 22 Termination 6Cx2.5Sqmm Unarm Ctrl Cable Both End. ( 2500 Mtr. ) 23 Delta Earthing, Fab Of 3X3m Electrode 40Mm 24 Cutting, Strengthening, Bending, Laying 1500Mm.Below In Side Ground And Above Ground Of Following Size Of Ms Flat For Earthing Of Main And Auxiliary Structure, Equipment Structure T / F Body And Its Material Etc. Including Welding With Main Earth Mat And With Object To Be Earthed / Excavation Of Trenches Its Back Filling. 25 Fresh Earthing, Connected With Earthmat 75X10mm 26 Fresh Earthing, Connected With Earthmat 50X6mm 27 Fresh Earthing, Connected With Earthmat 25X6mm 28 Interconnection Of Following Equipments And Bus Bar Including Cutting, Bending Of Conductor And Jumpering, Clamping Along With All Other Associated Work To Complete The Job Satisfactorily As Per Drawing And Technical Specn. 29 Eqpt Jumper Repl 1Xpanther, <10M, 132Kv 30 Eqpt Jumper Repl 1Xmoose, <10M, 33Kv 31 Laying Of Following Sizes Of Control Cable In The Cable Trench From Control Relay Panel To Various Equipments / Marshalling Boxes And Jb Etc. In Switchyard As Per Cable Schedule. 32 Laying 2Cx2.5Sqmm Unarm Ctrl Cable 33 Laying 4Cx2.5Sqmm Unarm Ctrl Cable 34 Laying 6Cx2.5Sqmm Unarm Ctrl Cable 35 Preparation Of Cable Schedule And Case Interconnection Diagram In Between Relevant Panels, Breakers. Ct, Pt, Cvt, Etc. 36 Stringing Of Single Moose 36 Mtr. Ofmain Bus Of 132Kv ( All 3 Phases ) Including Fitting Of Tension Clamps, Hoisting Of Isolators, Cutting Of Conductor And Shifting Of All Material From Store To Site And All Other Associated Works Required For Completion Of Job Satisfactorily As Per Technical Specification. 37 Stringing Of Single Moose 24 Mtr. Ofmain Bus Of 33Kv ( All 3 Phases ) Including Fitting Of Tension Clamps, Hoisting Of Isolators, Cutting Of Conductor And Shifting Of All Material From Store To Site And All Other Associated Works Required For Completion Of Job Satisfactorily As Per Technical Specification.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Jan-2023 Corrigendum Technical Bid 01-02-2023

Key Value

Document Fees
INR 590 /-
EMD
INR 10000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: ERECTION OF 01Nos. 132KV T/F BAY FOR 40MVA T/F AT 132KV S/S LALITPUR, UNDER ETD, JHANSI.
Sl. No. Item Description
1Name of Work
2Erection of following different type Main and auxiliary structure, columns, beams, peaks, masts ets. Suitable for placing of 132/33 KV equipments.
3ERECTION OF MAIN STRUCTURE
4Erection of following equipments as per Instruction manual of various equipments and technical specification including shifting of material / equipments from store to erection site including all other associated work to complete the job satisfactorily.
5ERECTION OF 145KV CB
6ERECTION OF 36KV VCB
7ERECTION OF 145KV BUS ISOLATOR.
8ERECTION OF 145KV TANDEM ISOLATOR.
9ERECTION OF SUBSTATION AUTOMATION SYSTEM PANEL.
10ERECTION OF 145KV CURRENT TRANSFORMER.
11ERECTION OF 120KV LIGHTNING ARRESTER
12ERECTION OF 145KV POST INSULATOR
13ERECTION OF JUNCTION BOX FOR 145KV CURRENT TRANSFORMER.
14ERECTION OF ABT ENERGY METERING PANEL WITH MAIN AND CHECK RACK.
15ERECTION OF 36KV CURRENT TRANSFORMER.
16REPAIR/REPLACEMENT WORK OF 120 KV LIGHTING ARRESTOR.
17ERECTION OF 36KV BUS ISO
18ERECTION OF JUNCTION BOX FOR 33KV CURRENT TRANSFORMER.
19Connection of the control & power cables as per new cable schedule of new 40 MVA T/F & its OLTC/RTCC Panels at both ends control & relay panel, cooling fans & pumps, marshalling box etc. using existing cable, including laying Dressing & Binding of additional control cables, if required as per site requirement and termination alongwith making necessary holes in the glands plates or box wherever required providing and fixing of cable glands of appropriate size, providing of ferrules and cable termination lugs as per standard & all other associated work as per technical specification including preparation of cable schedule drawing.
20TERMINATION 2CX2.5SQMM UNARM CTRL CABLE BOTH END. (1500 Mtr.)
21TERMINATION 4CX2.5SQMM UNARM CTRL CABLE BOTH END. (2000 Mtr.)
22TERMINATION 6CX2.5SQMM UNARM CTRL CABLE BOTH END. (2500 Mtr.)
23DELTA EARTHING,FAB OF 3X3M ELECTRODE 40MM
24Cutting, strengthening, bending, laying 1500mm.below in side ground and above ground of following size of MS Flat for earthing of main and auxiliary structure, equipment structure T/F body and its material etc. Including welding with main earth mat and with object to be earthed / excavation of trenches its back filling.
25FRESH EARTHING,CONNECTED WITH EARTHMAT 75X10MM
26FRESH EARTHING,CONNECTED WITH EARTHMAT 50X6MM
27FRESH EARTHING,CONNECTED WITH EARTHMAT 25X6MM
28Interconnection of following equipments and bus bar including cutting, bending of conductor and jumpering, clamping along with all other associated work to complete the job satisfactorily as per drawing and technical specn.
29EQPT JUMPER REPL 1XPANTHER,<10M,132KV
30EQPT JUMPER REPL 1XMOOSE,<10M,33KV
31Laying of following sizes of control cable in the cable trench from control relay panel to various equipments / marshalling boxes and JB etc. In switchyard as per cable schedule.
32LAYING 2CX2.5SQMM UNARM CTRL CABLE
33LAYING 4CX2.5SQMM UNARM CTRL CABLE
34LAYING 6CX2.5SQMM UNARM CTRL CABLE
35PREPARATION OF CABLE SCHEDULE AND CASE INTERCONNECTION DIAGRAM IN BETWEEN RELEVANT PANELS, BREAKERS. CT, PT, CVT, ETC.
36Stringing of single moose 36 Mtr. ofMain bus of 132KV (all 3 phases) including fitting of tension clamps, hoisting of isolators, cutting of conductor and shifting of all material from store to site and all other associated works required for completion of job satisfactorily as per Technical Specification.
37Stringing of single moose 24 Mtr. ofMain bus of 33KV (all 3 phases) including fitting of tension clamps, hoisting of isolators, cutting of conductor and shifting of all material from store to site and all other associated works required for completion of job satisfactorily as per Technical Specification.
Disclaimer :