| 1 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: All kinds of soil |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 3 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 5 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources). |
| 6 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20mm nominal size) over 75mm thick bed of dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling, dressing & finishing the top smooth. |
| 7 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for Stairs, (excluding landings) except spiral-staircases |
| 12 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 13 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 14 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 15 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tensile steel bars |
| 16 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flates, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding |
| 17 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 18 | Precast terrazo tiles 22 mm thick with graded marble chips of size upto 12 mm, laid in floors, and landings, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbingand polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement:4 coarse sand) : Light shade pigment using white cement |
| 19 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand)(a) In proportion 1:3. |
| 20 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 21 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) |
| 22 | Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). 6 mm thick Cement fiber board as per IS: 14862 |
| 23 | Extra for Circular cutting including wastages in ceiling with: White face insulating board 12 mm thick |
| 24 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood |
| 25 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately)Second class teak wood 35 mm thick shutters |
| 26 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 27 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer\"s specification. Two or more coats on new work |
| 28 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid |
| 29 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity - White |
| 30 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 31 | Providing and fixing kitchen sink including making all connections excludingcost of fittings. White glazed fire clay sink of size 600x450x250 mm |
| 32 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Circular shape 450 mm dia |
| 33 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 34 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 35 | Providing and fixing soil, waste and vent pipes : 100 mm dia Sand cast iron S&S pipe as per IS: 1729 |
| 36 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall. 32 mm nominal dia Pipes |
| 37 | Providing and fixing brass bib cock of approved quality : 20 mm nominal bore |
| 38 | Providing and fixing brass stop cock of approved quality : 20 mm nominal bore |
| 39 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 40 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 41 | Wiringforlightpoint/fanpoint/exhaustfanpoint/callbell point with1.5sq.mmFRLSPVCinsulatedcopperconductor singlecorecableinsurface/recessed steelconduit,with modular switch, modular plate, suitable GI box and earthing the pointwith1.5sq.mmFRLSPVC insulatedcopperconductor single core cable etc. as required. Group-A |
| 42 | Wiringforlightpoint/fanpoint/exhaustfanpoint/callbell point with1.5sq.mmFRLSPVCinsulatedcopperconductor singlecorecableinsurface/recessed steelconduit,with modular switch, modular plate, suitable GI box and earthing the pointwith1.5sq.mmFRLSPVC insulatedcopperconductor single core cable etc. as required. Group-B |
| 43 | Wiring for circuit/ submain wiring alongwith earth wire with the followingsizes of FRLS PVC insulatedcopper conductor,single core cable in surface/rcessed steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 44 | Wiring for circuit/ submain wiring alongwith earth wire with the followingsizes of FRLS PVC insulatedcopper conductor,single core cable in surface/rcessed steel conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 45 | Supplyingandfixingfollowingmodularswitch/socketon the existing modular plate & switch box includingconnectionsbut excluding modular plate etc. as required. 5/6 A switch |
| 46 | Supplyingandfixingfollowingmodularswitch/socketon the existing modular plate & switch box includingconnectionsbut excluding modular plate etc. as required. 15/16 A switch |
| 47 | Supplyingandfixingfollowingmodularswitch/socketon the existing modular plate & switch box includingconnectionsbut excluding modular plate etc. as required. 3 pin 5/6 A socket outlet |
| 48 | Supplyingandfixingfollowingmodularswitch/socketon the existing modular plate & switch box includingconnectionsbut excluding modular plate etc. as required. 6 pin 15/16 A socket outlet |
| 49 | Supplyingandfixingfollowingmodularswitch/socketon the existing modular plate & switch box includingconnectionsbut excluding modular plate etc. as required. Bell push |
| 50 | Supplyingand fixing twomodulestepped type electronicfan regulatorontheexistingmodularplateswitchboxincluding connections butexcluding modular plate etc. as required. |
| 51 | Supplyingand fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 4 Module (125mmX75mm) |
| 52 | Supplyingand fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm) |
| 53 | Supplyingand fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm) |
| 54 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 4 Module |
| 55 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 6 Module |
| 56 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 8 Module |
| 57 | Providing and fixing following capacity TP & N disconnectorfuse switchunit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections etc. as required. 32 ATP&N |
| 58 | Providing and fixing following capacity TP & N disconnectorfuse switchunit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections etc. as required. 63 ATP&N |
| 59 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volt, on surface/recess comlete with tinned copper bus bar, neutral bus bar, eart bar, din bar, inter connections, powder painted including earthing etc. as required.(but excluding MCB/RCCB/Isolator). 6 way , Double door |
| 60 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volt, on surface/recess comlete with tinned copper bus bar, neutral bus bar, eart bar, din bar, inter connections, powder painted including earthing etc. as required.(but excluding MCB/RCCB/Isolator). 8 way , Double door |
| 61 | Wiring forlight/ power plug with4X4sq.mmFRLS PVC insulated copper conductor single core cable in surface/ recessed mediumclass PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 62 | Supplyingandfixing5Ato32A rating, 240/415V, 10kA,\"C\" curve,miniaturecircuitbreakersuitableforinductiveloadof followingpolesinthe existingMCB DBcompletewith connections, testing and commissioning etc. as required.Single Pole |
| 63 | Supplyingandfixing5Ato32A rating, 240/415V, 10kA,\"C\" curve,miniaturecircuitbreakersuitableforinductiveloadof followingpolesinthe existingMCB DBcompletewith connections, testing and commissioning etc. as required.Double Pole |
| 64 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia includingaccessories,andprovidingmasonryenclosurewith cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 65 | Supplyingandlaying6SWGG.I.wireat0.50metrebelow groundlevel for conductorearth electrode,including connection/ termination with GI thimble etc. as required. |
| 66 | Providingandfixingof lightningconductorfinial,madeof 25mm dia 300 mm long, G.I. tube, having single prong at top, with 85mmdia6mmthickG.I.baseplateincludingholesetc. complete as required. |
| 67 | Supplyingandfixing3pin,5Aceilingroseontheexisting junction box/wooden block includingconnections etc. as required. |
| 68 | Installation,testing and commissioningof ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, includingprovidingandfixingphenoliclaminatedsheetcover on thr fan box etc. as required. |
| 69 | Supplyingand fixing following rating, four pole, 415 V, isolator in theexisting MCB DB complete with connections,testing and commissioning etc. as required. 40 A |
| 70 | Supplyingand fixing following rating, four pole, 415 V, isolator in theexisting MCB DB complete with connections,testing and commissioning etc. as required. 63 A |
| 71 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete withtesting and commissioning etc.as required. For 4 way, Double door TPN MCBDB |
| 72 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete withtesting and commissioning etc.as required. For 6 way, Double door TPN MCBDB |
| 73 | Laying ofone numberPVC insulated and PVC sheathed/ XLPE powercableof11KVgradeoffollowingsizedirectinground includingexcavation,sandcushioning,protectivecoveringand refilling the trench etc as required. Upto 120 sq. Mm |
| 74 | Supplying of following sizes XLPE insulated and PVC sheathed aluminium conductorarmored power cable of 11 KV grade conforming to IS 7098(Part - 1)/ 1988 with ammendment upto date etc. as required. 2X 10sq.mm. |
| 75 | Supply including fitting fixing of LED Tube Light 4 Ft. 20W 6500K, MAGIKmake CAT No. BWUA020W1295 as directed & specified by the deptt. |
| 76 | Supply of LED Bulb 15W, 1200 lumen, HPL make Product code HPLLEDB01265B22 as directed & specified by the deptt. |
| 77 | Supply including fitting fixing of A.C.Ceiling fanwith allaccessories like down rod, canopy etc. as directed & specified by the deptt.( HAVELLSmake) of MODEL- SS-390 METALIC 1200mm Sweep |
| 78 | Supply including fitting fixing of A.C.Exhaust fan of 300mm sweep in the existing holeincluding connections & making good damage done, complete as directed &specified by the deptt.( HAVELLSmake) of MODEL- Ventil Air - DSP METALLIC RANGE 300 mm. Sweep |
| 79 | Supplying fitting fixing of LED Street light uminaries with all acessories including connectionetc. complete as per direction of the department. |
| 80 | Supply including installation of Self Priming Mono Block Pump Set of 1 HP capacity as directed by the department.( Havells make ) |
| 81 | Payment to be made to APDCL authority for Load Security 6 k.w.load including installation of 3 phase Meter, Service connection etc. |