| 1 | Site Developmment: |
| 2 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materialsand stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. i)(A) In area of light jungle |
| 3 | EARTH WORK : |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. a)- All kinds of soil. |
| 5 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 6 | Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. a)- All kinds of soil. |
| 7 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 8 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : |
| 9 | Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. |
| 10 | CONCRETE WORK |
| 11 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work up to plinth level : |
| 12 | 1:5:10(1 Cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size). |
| 13 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(Zone III) : 4 graded stone aggregate 12.5mm nominal size). |
| 14 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 15 | REINFORCED CEMENT CONCRETE |
| 16 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 17 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 18 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 20 | Foundations, footings, bases of columns, etc. for mass concrete . |
| 21 | Suspended floors, roofs, landings, balconies and access platform |
| 22 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 23 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 24 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 25 | Thermo-Mechanically Treated bars |
| 26 | BRICK WORK |
| 27 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 28 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 29 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 30 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 31 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 32 | Cement mortar 1:4 (1 cement :4 coarse sand) |
| 33 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 34 | WOOD AND P.V.C. WORK |
| 35 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). |
| 36 | Kiln seasoned and chemically treated hollock wood |
| 37 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 38 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 39 | Providing and fixing ISI marked aluminium sheet on flush door shutters as specification & direction of engineer in charge as required colour and shade, with necessary screws etc. complete. |
| 40 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 41 | 300x16 mm |
| 42 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 43 | 300x10 mm |
| 44 | 250x10 mm |
| 45 | 150x10 mm |
| 46 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 47 | 125 mm |
| 48 | 100 mm |
| 49 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. |
| 50 | Twin rubber stopper |
| 51 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 52 | Fixed to openings /wooden frames with rawl plugs screws etc. |
| 53 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand: 6 graded stone aggregate 20mm nominal size). |
| 54 | FLOORING |
| 55 | Providing and laying cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone agg.40mm nominal size) excluding the cost of centring and shuttering in foundation and plinth |
| 56 | (a) Foundation and plinth |
| 57 | Providing and laying rectified Glazed Ceramic wall tiles of reqired size (thickness to be specified by the manufacturer), of 1stquality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4(1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. |
| 58 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete. |
| 59 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. |
| 60 | Size of Tile 600x600 mm |
| 61 | ROOFING |
| 62 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes. |
| 63 | 110 mm diameter |
| 64 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. |
| 65 | Coupler |
| 66 | 110 mm |
| 67 | Single tee with door |
| 68 | 110x110x110 mm |
| 69 | 110 mm bend |
| 70 | Shoe (Plain) |
| 71 | 110 mm Shoe |
| 72 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hardwood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 73 | 110 mm |
| 74 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 75 | FINISHING |
| 76 | 12 mm cement plaster of mix : |
| 77 | 1:6 (1 cement: 6 fine sand) |
| 78 | 15 mm cement plaster on rough side of single or half brick wall of mix: |
| 79 | 1:6 (1 cement: 6 fine sand) |
| 80 | 6 mm cement plaster of mix : |
| 81 | 1:3 (1 cement: 3 fine sand) |
| 82 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : |
| 83 | New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 84 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: |
| 85 | New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 86 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 87 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 88 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 89 | Neat cement punning |
| 90 | SANITARY INSTALLATIONS |
| 91 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 92 | W.C. pan with ISI marked white solid plastic seat and lid |
| 93 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : |
| 94 | Single half stall urinal with 5 litre P.V.C. automatic flushing cistern . |
| 95 | Providing and fixing white vitreous chinawater closet (Indian W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 96 | (a) W.C. pan with ISI marked white solid plastic seat and lid. |
| 97 | Providing and fixing white vitreous china wash basin with C.I. brackets/M.S. brackets, 15 mm pillar cock(Model no. 5011 of Florentine Series of Jaguar make or equivalent), 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required |
| 98 | White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 99 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 100 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 101 | Flexible pipe |
| 102 | 32 mm dia |
| 103 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : |
| 104 | Rectangular shape 453x357 mm |
| 105 | Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 |
| 106 | 75 mm diameter : |
| 107 | Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 |
| 108 | Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : |
| 109 | For 100 mm dia pipe |
| 110 | For 75 mm dia pipe |
| 111 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. |
| 112 | 100 mm dia |
| 113 | Sand cast iron S&S as per IS - 3989 |
| 114 | 75 mm dia |
| 115 | Sand cast iron S&S as per IS - 3989 |
| 116 | Providing and fixing plain bend of required degree. |
| 117 | 100 mm dia |
| 118 | Sand cast iron S&S as per IS : 3989 |
| 119 | 75 mm dia |
| 120 | Sand cast iron S&S as per IS : 3989 |
| 121 | Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. |
| 122 | 100x100x100 mm |
| 123 | Sand cast iron S&S as per IS - 3989 |
| 124 | 75x75x75 mm |
| 125 | Sand cast iron S&S as per IS - 3989 |
| 126 | Providing and fixing terminal guard : |
| 127 | 100 mm |
| 128 | Sand cast iron S&S as per IS - 3989 |
| 129 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : |
| 130 | 100 mm inlet and 100 mm outlet |
| 131 | Sand cast iron S&S as per IS: 3989 |
| 132 | 100 mm inlet and 75 mm outlet |
| 133 | Sand cast iron S&S as per IS: 3989 |
| 134 | Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for ew work : |
| 135 | 100 mm diameter pipe |
| 136 | 75 mm diameter pipe |
| 137 | WATER SUPPLY |
| 138 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall |
| 139 | 15 mm nominal outer dia Pipes |
| 140 | 20 mm nominal outer dia Pipes |
| 141 | 25 mm nominal outer dia Pipes |
| 142 | 32 mm nominal outer dia Pipes |
| 143 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 144 | 25 mm nominal bore |
| 145 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : |
| 146 | 20 mm nominal bore |
| 147 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 148 | 45 cm length |
| 149 | 15 mm nominal bore |
| 150 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISi : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 151 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931: |
| 152 | 15 mm nominal bore |
| 153 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 154 | 15 mm nominal bore |
| 155 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 156 | 15mm nominal bore |
| 157 | DRAINAGEWORK |
| 158 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : |
| 159 | 100 mm diameter. |
| 160 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: |
| 161 | 100 mm diameter. |
| 162 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : |
| 163 | Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 . |
| 164 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. |
| 165 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 166 | Construction of cement concrete drain 30 cm wide and 23 cm deep in cement concrete 1 : 3 : 6 (1 cement : 3 sand : 6 hard graded stone chips/shingle 40 mm and down gauge) 8 cm thick on sides and bottom and plastering on all exposed surfaces with 12 mm thick cement mortar1 : 3 (1 cement : 3 fine sand) including shuttering complete. |