Tender For Proposed Construction Of Production House With Storage Facilities For Finished Goods, Addition Of 3Rd Floor In The Existing Lac Value Addition Training Centre Cum Administrative Building Repair, Renovation Of Existing Factory Building, Bou, ranchi-Jharkhand

Jharkhand State Building Construction Corporation Limited has published Tender For Proposed Construction Of Production House With Storage Facilities For Finished Goods, Addition Of 3Rd Floor In The Existing Lac Value Addition Training Centre Cum Administrative Building Repair, Renovation Of Existing Factory Building, Bou. Submission Date for this Tender is 30-01-2023. Building Repair Tenders in ranchi Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

35694024
Tender For Proposed Construction Of Production House With Storage Facilities For Finished Goods, Addition Of 3Rd Floor In The Existing Lac Value Addition Training Centre Cum Administrative Building Repair, Renovation Of Existing Factory Building, Bou
Open Tender
Indian
Jharkhand
ranchi
30-01-2023

Tender Details

Proposed Construction Of Production House With Storage Facilities For Finished Goods, Addition Of 3Rd Floor In The Existing Lac Value Addition Training Centre Cum Administrative Building Repair, Renovation Of Existing Factory Building, Boundary Wall

Key Value

Document Fees
INR 10000 /-
EMD
INR 541000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:Proposed Construction of Production House with Storage Facilities for Finished Goods, Addition of 3rd Floor in the existing Lac value Addition Training Centre cum Administrative Building Repair, Renovation of Existing Factory Building, Boundary wall & Construction of Road & Gate for The Factory Campus of JASCOLAMPF Ltd. at Sidrol, Namkum, Ranchi
Sl. No. Item Description
1Taking down C.A. Or G.C.I. Sheet in roofs with ridges including stacking the serviceable materials within 15M. Lead and disposal of unserviceable materials with all leads as per direction of E/I.
2Taking down wooden or steel truss and M.S. Joists, including stacking the serviceable materials within 15M. Lead and disposal of unserviceable materials with all leads as per direction of E/I.
3Taking down old door and window shutters including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
4Taking down chaukhats in doors including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
5Taking down chaukhats in windows including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
6Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
7Dismantling plain cement or lime concrete workincluding stacking serviceable materials in countable stacks within 15M lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
8Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item-A) and disposal of excavated earth as obtained to a distance upto 50 M. including all lifts, levelling, ramming the foudation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/l.
9Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches withina lead of 50Mand lift of 1.5M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
10Earth filling in foundation trenches and plinth in layers not exceeding 150 mm. thick well watered, rammed, fully compacted and fine dressed with earth obtained after cutting within a lead of 50 M. and lift of 1.5 M all complete as per building specification and direction of E/l (Mode of measurement compacted volume).
11Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including" cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/l (Mode of measurement complacted volume).
12Providing designation 75 A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l.
13Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- all work upto plinth level - 1:3:6 (1 cement : 3 coarse sand (zone - III): 6 graded stone aggregate 20mm nominal zie)
14Providing designation 75 A brick work in C.M.(1 :6) in foundation & Plinthwith approved quality of clean coarse sand of F.M. 2 to2.5 including providing 10 mm thick mortar joints cost of screening materials , scafolding , raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l.
15Providing designation 75 A brick work in C.M.(1 :6) in superstructure with approved quality of clean coarse sand of F.M. 2 to2.5 including providing 10 mm thick mortar joints cost of screening materials , scafolding , raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l.
16Providing designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"X4.5"X3") in C.m. (1:6) in super structure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I
17Providing designation 125 mm thick reinforced designation 75 A brick work in C.M (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials , scafolding, raking out joints to 15 mm depth, curing, taxes and royalty ( but excluding the cost of reinforcement) all complete as per building specification and direction of E/l.
18Providing designation 112mm thick reinforced designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"X4.5"X3") in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening carriage of materials, scaffolding, raking out joints tom 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
19Extraforbrick workfor EACHconsecutive floor abovefirst floor including watering and scafolding, all complete as per direction of E/l.
20Providing and laying in position specified grade of reinforced cement concreteexcluding the cost of centering and shuttering, finishing and reinforcement - all work upto plinth level1:1.5:3 (1 cement : 1.5 coarse sand (zone - III): 3 graded stone aggregate 20mm nominal zie)
21Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and structs etc. above plinth level upto floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III) : 3 graded stone aggregate 20mm nominal size)
22Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases, above plinth level upto floor five level, excluding the cost of cenetering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III): 3 graded stone aggregate 20mm nominal size)
23Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size).
24Centering and shuttering including strutting, propping etc. and removal of form for
25Foundations, footings, bases of columns, etc. for mass concrete
26Suspended floors, roofs, landings, balconies and access platform
27Lintels, beams, plinth beams, girders, bressumers and cantilevers
28Columns, Pillars, Piers, Abutments, Posts and Struts
29Stairs, (excluding landings) except spiral-staircases
30Providing tor steel reinforcement of 8mm.dia. rods as per approved design and drawing with cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position (excluding carriage ofbars to work site) all complete as per building specification and direction of E/l. TMT FE 500 ( only valid forTata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro, & Vizag (RINL)
31Providing tor steel reinforcement of 10,12,16mm .dia. rods as per approved design and drawing with cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position (excluding carriage ofbars to work site) all complete as per building specification and direction of E/l. TMT FE 500 ( only valid forTata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro, & Vizag (RINL)
3210mm dia-
3312 to 25mm dia
34Supplying, fitting and fixing 35mm thick solid core type non-decorative double leaf flush shutter in door and windowswith black board core blended with high qualityphenol formal dehydes synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I.
35Supplying, fitting and fixing 35mm thick solid core typedecorative single leaf flush door shutter with both sides decorative veneered with block board core bended with high quality phenol formal dehydes synthetic resin of standard make with aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I.
36Supplying, fitting and fixing 35mm thick solid core typedecorative double leaf flush door shutter with both sides decorative veneered with block board core bended with high quality phenol formal dehydes synthetic resin of standard make with aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I.
37Providing & fixing pressed steel door frames manufacturedfromcommercialmild steelsheet of 1.25mm thickness including hinges ,jamb,lockjamb,beadand if requiredangle threshold of mild steel angle section 50 X 25mm, orangle threshold of mild steel angle section 50 X 25mm, orbase ties of1.25mm pressedmild steel welded or rigidlyfixed together by mechanical means, adjustable lugs withsplitendtailto eachjambincludingsteelbutt hinges splitendtailto eachjambincludingsteelbutt hinges 2.5mmthickwithmortarguards,lockstrike-plate and 2.5mmthickwithmortarguards,lockstrike-plate andshockabsorbersasspecifiedandapplyinga coatof approvedsteelprimerafterpre-treatment of the surface as directed by the Engineer Incharge - Profile - B- Fixing with adjustable lugs with split end tail to each jamb
38Providing and fixing 1mm thick M.S. sheet door with frame of 40X40X6mm angle iron and 3mm M.S. gusset plates at the junctions and corners all necessary fittings complete, including applying a priming coat of approved steel primer -using M.S. angles 40X40X6mm for diagonal braces
39Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. compelte -2nd class teak wood -50X20mm
40Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinfoorced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers specification and direction of Enginner-in-Charge.
4130mm thick factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm . 19mm for styles and 15x15mm for top & bottom rails, M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5mm thick heat moulded PVC "C" channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45 degree angle on eigher side forming styles: and 5 mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mmshall be tapered in 45 degree on the inner side to form top and bottom raiil and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail.
42Top, bottom and lock rails shall be provided eigher side of the panel. 10mm (5mm x 2) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded / sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the "C" Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge. Manufacturer"s specificatio n& drawing (for W.C. and bathroom door shutter).
43providing and fixing ISI markedaluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) tramsparent or dyed to required colour or shade with necessary screws etc. complete 125X75X4mm
44Providing and fixing luminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS 1868) transpoarent or dyed to required colour or shade with necessary screws etc. complete 150X10mm
45Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS 1868) transparent or deyed to required colour or shade with nuts and screws etc. complete 250X16mm
46Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriateZ sections and other sections of approved make conforming to IS : 733 and IS: 1285 fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc.. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling C.P. brass / stainless steel screws, all complete as per architetural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately)
47For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required inlcluding the cost of EPDM rubber/neoprene gasket required (fittings shall be paid for separately) --- Polyester Powder coated aluminium (minimum thickness of powder coating 50 micron)
48Providing and fixing glazing in aluminium door, window, ventilator, shutters and partitions etc, with EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (cost of aluminium snap beading shall be paid in basic item)With float glass panes of 4mm thickness (weight not less than 10kg/sqm.)
49With float glass panes of 8mm thickness (weight not less than 10kg/sqm.).- (Aluminium door).
50Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2 mm at 100mm. centres and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40x40x6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangements, stoppers, handles, including applying a priming coat of red lead paint, carriage , hoisting and taxes all complete as per building specification and direction of E/l.
51Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.)
52Providing and fixing fan hook of 16mm dia M.S. bar 1 metre long bent to required size and shape, placed in position and fixed in R.C.C. slab/beam at the time of casting all complete as per building specification and direction of E/l. (where material is not supplied by deptt.)
53Supplying, fitting and fixing fully glazed steel door, window or ventilations of standard rolled "Z" and mullion steel sections and size as per IS-1038 jointsmet and welded with 100X16X3mm M.S. lugs fixed in cement concrete (1:2:4) block 15X10X10cm, size including cost of oxidised iron fittings, with hinges, handle per steps, catch springs, 3mm thick plain glass panes with Aluminimum beads and inner frame fixed with lugs with 20mm long 6.3mm G.I. counter sunk machine screw and nuts and applying a coat of red lead paint carriage to work site hoisting and placing in position in all storys and taxes all complete as per building specification and direction of E/I.
54Steel work welded in built up sections/framed work including cutting hoisting fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
55Providing and fixing stainless steel (grade 304) railing made of Hollow tubes, channels, plates etc,. Including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessry stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasterners, stainless steel bolts etc. of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasterners etc,.)
56Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layers 19mm. Thick (1:2:4)with 12mm to 6mm. Size graded stone chips and top layer 6mm. Thicks (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I.
57Providing 1.5mm cement punning including curing, carriage of water with all leads and lift as per building specification and direction of E/I.
58Providing and laying Doublecharge Vitrified floor tiles in different sizes (thickness to be specificed by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622/ISO 13006 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete size of tiel 600X600mm
59Providing and laying rectified glazed ceramic floor tiles 300x300mm or more (thickness to be specified by manufacturer) of 1st quality conforming to IS:15622 with approved make in all colours,shades,except white, ivory, grey, fume red, brown laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3 Kg/sqm. including pointing the joints with white cement and matching pigments, etc.complete.
60Providing and fixing 18mm thick gang saw cut mirror polished (premoulded & prepolished) machine cut for kitchen platform and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base of cement mortar 1:4 (1cement :4 coarse sand) laid and jointed with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels. Granite slab
61Providing edge moulding to 18mm thick marble stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge Granite work
62Providing and laying 25mm thick kotah stone slab flooring of approved size, texture and colour over 19mm thick base of lime mortar (1:1:1) (1 lime putty sucrkhi coarse sand) laid over and jointed with grey cement slurry mixed with pigement to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.- 600 X 600mm size
63Providing and laying 25mm thick kotah stone tiles in risers of steps skirting and pillars of approved size texure and colour laid over 12mm thick cement mortar (1;30 and joined with grey cement slurry mixed with pigment to match the shade of the slab including rub bing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
64Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing, polishing and cost of curing, taxes and royalty all complete as per building specification and direciton of E/l.With "A" grade white 15 x 15 cm tiles.
65Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grde made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of course sand, filling the joints with coarse sand etc. all complete as per the durection of Engineer-in-charge.
66Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curingwithall leadsand liftsof water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
67Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5including screening, curingwithall leadsand liftsof water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
68Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5with 5% cico or any other approved water proofing compoundincluding taxes and royalty all complete as per building specification and direction of E/l.
69Extra for plaster work over exterior surface for each consecutive floor above first floor including cost of scaffolding etc, all complete as per direction of E/I.
70Providign and applying Plaster of Paris Putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
71Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered syrface bv rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, sacffolding washing of floors and taxes all complete as per building specification and direction of E/I,
72Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
73Finishing walls with premium acrylic smooth exterior paint with sillicone additives of requited shade . New work : 2 or more coats applied @1.43 Ltr/10sqm over and including base coat of waterproofing cement paint applied @2.2 Kg/10 sqm
74Providing two coats of synthetic enamel paint of approved shade and make over new wooden surface including cleaning the surface after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
75Providing French spirit polishing over new wooden surface to give desired texture and gloss with approved make and shade of ready mixed French polish including cleaning the surface after removing dirt, scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specifcation and direction of E/I.
76Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l.
77Providing & laying water proofing treatmentin sunken portion of WCs, bathrooms etc. by applying cement slurry mixed with Armourcrete of M/S The Structural Water Proofing Company PVT. Ltd.or Tapecrete of M/s CICO Engg. Servce consisting of applying :
78(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with Armourcrete or Tapecrete @0.125 kg/ sq.m. This layer will be allowed to air cure for 4 hours
79(b)second layer of slurry of cement @ 0.242 kg/sqm mixed with Armourcrete or Tapecrete @0.126 kg/ sq.m. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.
80The rate includes preperation of surface, treatment& sealing of all joints, corners, junctions of pipes & masonary with polymer mixed slurry.
81Water proofing for old and new roof slab - Providing and laying water proofing treatment on roof slab by applying two component, factory designed, ready to use acrylic modified flexible material applied with brush roller or spray for water proofing coating as per manufacturer specifications with gollowing steps:
82a.Surface preparation - Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint/coating and cement laitance by cleaning with compressed air & water jet including all matrials, labour, tools, complete, ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage leakage.On identification of seepage cement grouting to be done with non shrink expanding adminxture of Sika India Pvt Ltd./MYK schomberg/Dr. Fixit/Fosroc or equivalent.Providing and repairing of all corners and joints such as those between the parapet wall and the roof slab etc. sahll be chamfered with 150mm X 150mm fillet of mortar (cement, sand 1:4) admixed with acrylic polymer of Sika/Fosroc/MYK scholmberg/Dr fixit or equivalent.Before chamfering a prime coat shall be given with the slurry of acrylic polymer,Repairing surface irregularities, damaged concretein base slab dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.
83b.1st coat -Apply 1st coat of two component acrylic modified, ready to use flexible cementitious material on surface saturated dry roof and inside wall of parapet wall upto 600mm by brush or roller.After 1st coat of application, 45 gsm of fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @ 1.50kg/sqmt/coat.Fore the prupose of measurement the entire treated surface will be measured.
84c.2nd coat - To apply the 2nd coat of two component acrylic modified, ready to use flexible cementitious material on right angle to the 1st coat over the glass fibre laid surface 2nd coat should be applied @ 0.7kg/sqmt/coat.For the purpose of measurement the entire treaed surface will be measuredAfter three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C.The water proof coating to be protected from damage before screed over it.Water proofing brand Sika Topseal 109hi/Fosroc Brushbond RFX/Dr Fioxit Pidiffin 2K/MYK Aquafin TG.Product performance- Chemical base part A Acrylic copolymer, Part B Specially graded cementitious powdere density 1.6 kg/I (mixed density) at +27 degree C. Tensile strength - 2N/mm2 after 28 days (with fibre cloth) (according to ASTM D 2370) Pullout bond strength - 2 N/mm2(concrete failure) (According to ISO 4624) slant-shear bond strength - 4N/mm2 (according to FIP 5.15) Elongation at break - 35% without fibre cloth and 20% with fire cloth (according to ASTM D 2370)
85d. Protection of treated surfaces with PCC ;The treated syrface shound be covered with 25mm/50mm PCC of M-20 grade (1:1.5:3) with proper slope (1:120) towards the rain outlets in alternate panels of 2 mt X 2 mtr. Keeping 6mm gap between the panel joint integral water proofing admixture conforming to IS 2645 @ of 100ml per bag of cement to be added in the screed concrete (Paid separately for this items)All corners shall be chamfered with 150mm X 150mm fillet.The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - peripherial gaps between PVC pipe outlet and concrete surface should be packed properly with rich concrete nd the peripherial mouth to be sealed with mosture insensitive epoxy putty of sika India Pvt. Ltd/MYK schomberg/Dr. Fixit/Fosroc.For purpose of measurement the entire treated surfaces will be measurede,Grooves of PCC surface should be filled with polysulphide sealant.Brand - Sika India Pvt. Ltd. /MYK Schomberg/Dr. Fixit/Foscroc warranty for five years.
86Covering of treated surface with PCC - Providing 25mm thickCement Concrete M-20 (1:1.5:3) maintaining slope in alternte 2 mt X 2 mt panels with approved quality of stone chips of 20mm to 6mm size graded and cleaned sand of F.M. 2.5 to 3 including screening, shuttering, and mixing cement concrete in mixer with adminxture of integral water proofing and placing in position striking curing, taxes and royalty all complete as per building specificastion and direction of E/I.Panels that has been left should be casted next day.There should be 6mm gap between panels brand - Sika-Plastocrate plus, MYK proof WP 10, Fosroc - Conplast X 421ic,Dr. Fixit pidiproof LW+
87Providing and filling 6mm thick groove between 25mm PCC panelswith polysulphide sealant (Poring Grade) as per drawings and technical specifications and direction of E/C (with 18%GST) brand - Sika-Polysulphide, Fosroc-Thioflex 600, Dr. Fixit Piddiseal PS (42P) MYK seal PS or equvalent
88Providing & fixing on wall face unplasticised -Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socketed pipes. 110 mm dia
89Providing and fixingon wall face unplaqsticised- PVCmoulded fitting/ accessories for unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A,includingjointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
90Bend 87.5 degree - 110X110X110mm
91Shoe plain -110mm
92Providing and fixing to the inlet mouth of rain water pipe cast iron grating15 cm diameter and weighing not less thaN 440 grams.
93Providing and fixing unplasticised PVC pipe clips of approved design to unplasticised PVC rain water pipes by means 50X50X50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc. complete -110mm
94Providing 250 mm wide BRICK DRAIN in cement mortar (1:6) with avarage 150mm. Clear depth and 250 mm apron including cost of earthwork involved with 75m cement concrete (1:4:3) over one brick designation 75A, flat soling in proper grade and slope at the base , the drain dully plastered in C.M.(1:3) with puning over exposed surface all complete as per building specification and direction of E/I.
95Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated andgroutedwithfinesand,includingnecessaryexcavation,levelling& dressing & finishing the top smooth.
96Providing & injecting chemical emulsion for pre-construction Anti-termite treatment and creating a chemical barrier underand allaroundthe coloum pits,wall treanches,basement excavation, top surface of plinth filling,junctions of wall and floor along the external perimeter of building with approved chemical as per IS code As per specification and direction of E/I.
97Cutting of trees excluding removal of stumps and roots of trees,
98Steel work welded in built up sections/framed work including cutting hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required - In gratings, frames, guard bar, ladder, railings, brackets gates and similar works
99Carriage of materails
100Bricks- Lead-7+1km.
101Sand- Lead10km
102Chips - Lead22km
103Metal - Lead22km.
104Earth - Lead2km.
105PLUMBING WORK
106Supplying, fitting and fixing vitreous white glazed earthen ware I.W.C. of parry hindustan or any other ISS approved make with 100mm HCI p trap 15 litres CI pull and let go flushing cistern of names or other ISS equivalent make complete with all fittings CI or C C bracket 32mm alkethene / PVC telescopic flushpipe about 2m long with one brass coupling and clamps GI chain and pull including supplying and fixing a pair of vitreous white glazed earthenware footrest to be fixed in floor 15mm CI body brass spindle stop cock of weight not less than 50 grames 15mm PVC connection pipe 450mm long and coat of red oxide primer etc all complete as per specification and direction of E/I. (A) 580 mm longwith 12.5 litre low level PVC cistern
107Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware E.W.C. with "p" trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. (A) With "P" trap(b)12.5 lit. low level P.V.C. cistern
108Supplying, fitting and fixing flat back or angular lipped front vitreous white glazed earthern ware urinal of Hindustan "Parry" or any other approved ISS make with 5 ltrs. Capacity C.I. automatic fushing cistern of reliance for any other ISS approved make with all fittings with C.I. or RS brackets standard size G.I. flush pipe with fitting clamps 15mm C.I. body brass spindle stop cock of approved quality weight not less than 400 gms.15mm PVC alkethene pipe 450mm long with brass coupling at both ends and doing plumber points including painting of exposed part with two coats of approved paint over a priming coat of red oxide cutting wall and floor making good the same etc. all complete as per speciifcification and direction of E/I. Flat back or standing corner (600X350mm)
109supplying fitting and fixing vitreous white glazed earthen ware wash hand basin of parry or hindustan or any other I.S.S approved make supported on painted C.I OR R.S bracket 32mm C.I brass waste 15mm dia C.I body brass spindle stop cock of approved quality of weight not less than 350 grames, 32mm PVC wate pipe 750mm long with brass coupling with one end and making plumber joints etc.all complete as per specification and direction of E/I.
110Supplying, fitting and fixing gun metal full way valve of approved quality all complete as per specifcation and direction of E/I.
11120mmdia.
11225mmdia.
11332mmdia
11440mm dia
115Providing and fixing brass stop cock of approved quality all complete as per specification and direction of E/I.… 15mm dia.
116Cutting drain width wise above GL for laying PVC pipe and restoring brick work in cement mortar (1:4) 12mm cement plaster in C.M. (1:4) with neat cement punning as per specifciation and direction of E/I. (PVC 110mm dia)
117Making holes in wall for laying PVC pipes and restoring the same all cost complete (PVC pipe 110mm dia)
118Supplying all tolls and labour and cutting chajja cornice for laying PVC pipes and making good the same as per specification and direction of E/I. (110mm dia PVC pipe)
119Supplying, fitting and fixing bathroom fittings of approved make and as per IS specification all cost complete as per direction of E/I.(all rates have been adopted from the basic rate from SOR + 30% for labour and Contractors profit)
120Pillar cock (long neck)
121Bib cock - long thread
122Angular stop cock L.T.
1234 way diverter for concealed fittings
124Glass shelf
125Flush valve complete with 32mm size control cock & flange
12632mm dia. PVC waste pipe 750mm long with coupling
12715mm C.P. nipple with coupling
128Steel jali- 100mm dia.
129Providing Solvent cement
130Supplying, fitting and fixing Mirrors of 6mm thick plate glass bevelled edge mirror including C.P. brass revolving fittings 3mm ply wood board and C.P. hinges to fix with mirror.600 X 450mm
131Supplying, fitting and fixing C.P. brass towel rail 20mm X 600mm with bracket container
132Supplying, fitting and fixing C.P. brass soap dish container medium quality with screw and hinges etc.
133Providing and fixing 15mm dia and 45cm long PVC connection pipe with heavy quality brass coupling at both ends etc all complete as per specification and direction of engineer in charge
134Providing and fixing C.P. brass bib cock of approved quality conforming to IS 8931,15mm dia nominal bore of approved brand C.P. fittings
135Providing and fixing PTMT extension nipple 15mm size with 12" BSP thread 70mm length and 30mm breadth and weighing not less than 18gms of approved make
136Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittingsi.e fixing the pipe with clamps at 1Mtr. Spacing. This includes jointing of the pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. Concealed work including cutting chases and making good the walls etc.
13720mm nominal bore
13825mm nominal bore
13932mm nominal bore
140External work -40mm nominal bore
141Providing & fixing on wall face unplasticised -Rigid P.V.C.pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socketed pipes. 110 mm dia
142Providing and fixingon wall face unplaqsticised- PVCmoulded fitting/ accessories for unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A,includingjointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
143Single Tee with door -110x110x110 ,mm
144Bend 87.5 degree- 110 mm bend
145PVC cowl - 100mm dia.
146Floor trap - 100mm dia.
147Providing and placing on terrace (at all floor levels) (PVC) Polyethylene water storage tank ISI 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
148Providing and fixing 8mm dia C.P./S.S. jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer-in-charge
149Providing and fixing Pressure adjustable shower with revolving joint(Basic rate Rs.766.95 +10% for C.P.)
150Cutting chajjas or concrete for laying PVC Pipe and restoring the same with R.C.C. (1:2:4) brick work in cement Mortar (1:4) and cement plaster 1:4 as per specifiction and direction of E/I
151Making holes in walls for PVC Pipe and restoring the same atfer pipe Laying (b) 250mm thick wall
152ELECTRCIAL WORK
153Point Wiring in PVC Conduit, with Modular type Switch: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required.
154Supply and Fixing Light Plug Point with Modular Type Accessories: Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc as required.
155Supply and Fixing Light Plug Point with Modular Type Accessories: Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required.
156Supply & fixing 20A SPN MCB Industrial Socket Outlet: Supply and fixing of 20A, 240V, SPN insustrial type socket outlet with 2 poles and earth, metal enclosed plug top along with 20 amps "C" series, SP MCCB, in sheet steel enclosure, on surface or in recess withchained metal cover for socket out let and complete with connections, testing and commissioning etc as required.
157Circuit / Sub-main wiring in PVC Conduit:Wiring for circuit / sub-main wiringalong with earth wire with thefollowing sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required.
1582x1.5 Sqmm + 1x1.5 sqmm earth wire
1592x2.5 Sqmm + 1x2.5 sq mm earth wire
1602x4 Sqmm + 1x4 sq mm earth wire
1614x6 Sq.mm + 2x6 Sq.mm earth wire.
162S/F TP MCB DB:-Supplying and fixing of following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (Without MCB/RCCB/ISOLATOR). (All TP MCB DB shall be as per IS:8623)
1634 Ways (4+12 ways) double door
164S/F "C" series MCB:-Supplying and fixing 240 volts, "C" series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required.
1656/32A Single Pole
1666/32A TPN MCB
16750/63A TPN MCB
168S/F Ceiling Rose: Supplying andfixing 2 pin ceiling rose on the existing junction box/ wooden block including connection etc as required.
169S/F Modular type electronic fan regulator: Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required.
170ITC Exhaust Fan upto 450 mm sweep: installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to cut the size of the above fan, making good the damage,including connection, testing, commissioningetc as required.
171S/F Batten / Angle Holder: Supplying and fixing batten / angle holder including connection etc as required.
172S.I.T.C of following rating surface mounted LED tube light fittings suitable for 230V, 50Hz, single phase supply etc. complete as required- 20/22W. LED tube light
173Bulk head fitting with 9/10Watt CFL/LED
174Supplying, 15/16 Watt LED bulb of approved make
175SupplyingExhaustfan of 12" (300mm) of aproved make
176Supply, installation, testing and commissioning of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standard length (upto 30cm) with 1.5sq.mm. FR. PVC insulated copper wire suitable for 230V, 50Hz, single phase supply etc. complete as required. -1400mm (56") ceiling fan
177S.I.T.C. of following rating recess/surface mounted LED round/square shape down light luminaire with pressure die cast housing for single phase supply Voltage.Luminaire shall be confirm to IS:10322 Part -5/section 2 of IEC:62722 with all necessary accessories as required- 18/20W LED round down light
178S.I.T.C. of following rating LED street lighting luminarie die cast housing and toughened glass cover (IP-66 portion) in existing pole/pipe for supply voltage 100-270V. AC, 50Hz.Luminaire shall be confirm to IS:10322 part - 5/section 3 and shall be complete with all necessary accessories as required- 60W LED street light
179GI Earth Pipe Electrode: Earthing with G.I. earth pipe 4.5 mtr long , 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcol and salt complete as required.
180Supplying and nlaying 25mm X 5mm G.I. strips at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required (jointing shall be done by overlapping and with 2sets of G.I. nut bolt & spring washer spaced at 50mm)
181Providing and fixing 25mmx 5mm G.I. strip on surface or in recess for connection etc. as required
182Provioding and laying 1.1 KV grade aluminium armoured cable as per IS 1554 (Part I) heavy duty all cost complete including cost of brass compression gland, cable jointing and end termination as per specification and direction f E/I.
1833.5 core, 50 sq.mm
1843.5 core, 35 sq.mm
185Fabrication, assembling 200A HRC TPN switch incoming and 100/63A TPN, 35KA MCCB outgoing 4 nos. lighting LT electrical sub distribution control panel with the foloowing accessoires:
186a. 200A TPN HRC switch - 1no.,b.300A aluminium busbar - 1set, c.100/63A TPN, 35KA MCCB- 4 nos.,d.0-500V voltmeter with selector switch - 1 set, e.200/5A Amperemeter with selector switch 1 set, f.200/5CTS - 3 nos.,g.RYB indication lamp - 3 nos.,h.15A HRC kitkat with fuse - 3 nos.i.Panel wiring material copper wire, lug hardware etc. 1 set. j.16 SWG MSCRsheet suitable size and enclosure duly painted dust and verbing proof with locking arrangement complete 1 set
187BOREWELL
188Costs of drilling 200mmX165mmX125mtr. Deep borewell in all kinds of soil and rock in rural area for installation of pump set with Hydraulic DTH rig machine, all complete including supplying all materials, tools, drilling rig, Air compressor and equipments, as well as fuel lubricants and cost of transportation of rig machine and other vehicles upto the site
189From 0-50 mtr.
190Above 51 mtr.to 125 mtr
191Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia conforming to IS : 12818, including required hire and labour charges fittings & accessories etc. all complete for all depths, as per direction of Engineer-in-charge- 200mm nominal size dia
192Gravel packing in tube well construction in accordance with IS : 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge
193Development of tube well in accordance with IS 2800 (part 1) and IS: 11189 to establish maximum rate of usable water yield without sand content (beyond permissible limit) with required capacity air compressor, running the compressor for required tile till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, colleting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete including hire & labour charges of air compressor, tools & accessoires etc. all as per requirement and direction of Engineer-in-charge.
194Providing & fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/casing pipe, removable as per requirement, all complete for borewell of200mm dia
195Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS:2800 (Part-1) including necessary bolts & nuts of required size complete
196Providing and fixing bail plug/bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS :2800 (Part-1) 200mm dia
197Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pioes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings.This includes jointing of pipes & fittings with one step CPVC solvent cement trenching, refilling & testing of joints complete as per direction of Engineer in charge
19850mm nominal outer dia pipes
199Supplyingsubmersible pumps sets confirming to IS:8034 and motor confirming to IS:9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller, motor suitable for working on 415V+10%, 3PH. 50HZ, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thrust, water proof winding shall be provided.the pump set shal be suitable for direct couplings, pump shall have suitable outlet as per manufacture design.Anti thrust stream lined non return valve shall be provided with pump.3 mtr. submrsible copper conductor cable in single/double run shall be provided with each pump.
200Submersible pump set 100mm dia (with polypropylene/noryl impeller) upto 20 stage-3.0 HP
201NON-SCHEDULED ITEMS
202Supplying,and installing 10 passenger lift of approved make with the following specifications:
203Capacity - 10 persons, Speed 1 mps, 4 stops with all opening on the same side, machine PM Gearless (located in shaft on top of guide rails), Stainless steel finish , handrails - stainless steel mirror finish, DC door operator.
204Add 18% GST
205Add 1% GST
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail