Tender For Establishment Of Advanced Virus And Other Pathogens Diagnostic And Testing Service Centre For Plant Propagation Materials For The Benefit Of The Farmers And Entrepreneurs In West Bengal, mohanpur-West Bengal

Bidhan Chandra Krishi Viswavidyalaya has published Tender For Establishment Of Advanced Virus And Other Pathogens Diagnostic And Testing Service Centre For Plant Propagation Materials For The Benefit Of The Farmers And Entrepreneurs In West Bengal. Submission Date for this Tender is 26-01-2023. Rolling Hardware Tenders in mohanpur West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

35690424
Tender For Establishment Of Advanced Virus And Other Pathogens Diagnostic And Testing Service Centre For Plant Propagation Materials For The Benefit Of The Farmers And Entrepreneurs In West Bengal
Open Tender
Indian
West Bengal
mohanpur
26-01-2023

Tender Details

Establishment Of Advanced Virus And Other Pathogens Diagnostic And Testing Service Centre For Plant Propagation Materials For The Benefit Of The Farmers And Entrepreneurs In West Bengal - Plant Growth Chamber With Laminar Flow : • Chamber Internal Capacity Should Be Minimum Between 1200 – 1300 Ltrs • Temperature Range 00C To 400C Lights Off +50C To 400C Lights On Or Better• Temperature Stability + / -0.50C Or Better• Humidity Range: Upto 95% Lights Off & 80% Lights On Or Better• Humidity Stability + / - 3% Rh Or Better• Chamber Should Be Supplied Water Storage Tank Approx. 15 To 20 Litrs For Humidity Water Storage. Humidifiction Should Be Ultrasonic Humidification Or Equivalent For Better Humidity Uniformity• Fluorescent Lamps Properly Located Horizontally Tier Tray Which Must Be Adjustable To Provide A Uniform Light Intensity Throughout The Shelf. • Light Intensity Must Be 290 Micromoles / M2 / S Or More Per Shelve And Should Be Dimmable From 100% To 10%. Chamber Should Be Supplied With Two Light Try Shelves.• Control Panel For Temperature; Humidity And Photoperiod With Touch Screen Display With Real Time Circadian ( Countdown ) Programming. Programs Can Run In Ramping Or Non-Ramping Or Diurnal Modes.• There Must Be Provision That Chamber Should Accomodate Led Light Trays In Fututre At No Extra Cost On Hardware But Only Taking The Extra Led Light Shelf• Air Circulation Inside The Chamber Should Be From An Air Diffuser & Should Travel Along The Entire Back Wall Over The Shelves Should Be Adjustable To Plant-Specific To Ensure Uniform Transpiration And Optimum Excahnge Of Gases • Doors Must Be Reach-In Door With Magnetic Gasket To Provide Tight Seal And With Lock & Key For Each Door • Independent High / Low Temperature Safeties Adjustable Must Be Availabe For Chamber Utilizing An Independent Sensor.• Chamber Interior Should Be Made From Corrosion Resistant Ss Or White Plastic Coated Aluminium And Exterior Should Be Plastic Coated Steel. It Should Have Castor Wheels For Easy Mobility. Should Be Supplied With Air Cooled Refrigeration System With Cfc Free Refrigerants. • It Should Be Operable With Single Phase, 230V Ac & 50 Hz With Power Less Than 2Kw And Electircal Should Be Ip Protected• Internal 1310Mm ( W ) X 675Mm ( D ) X 1410Mm ( H ) , External 1440Mm ( W ) X 810Mm ( D ) X 1975Mm ( H ) , Volume 1200 Litres Nominal 2 Gel Electrophoresis : Mini Horizontal Electrophoresis:• System Should Be Completely Self Contained System Designed For Quick Checks Of Samples.• Gel Casting, Running And Analysis All Should Be Performed In The Same Unit.• Should Have Uv Transparent Base To Allow Direct Viewing On A Uv Transilluminator.• Gel Dimensions Should Be 10X8cm.• Should Have In-Built Tray With Dual Comb Slots.• Two Combs Of 1.5Mm Thickness For 8 Samples Should Be Provided With The Unit.• Casting Dams Should Also Be Included For Tape Free Casting.• Buffer Volume Should Not Be More Than 50Ml.• Should Be Able To Run Maximum Of 40 Samples.• Option For Multichannel Compatible Combs.• The Unit Must Have Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use – Part 1: En61010-1: 2001, General Requirements Following The Provisions Of Directives 73 / 23 / Eec ( Low Voltage ) And 89 / 336 / Eec ( Emc ) As Amended By 93 / 68 / Eec ( Ce Marking ) .Msmidi10 Horizontal Electrophoresis:• The Horizontal Electrophoresis Unit Must Include 10X10cm Tray.• Gel Trays Should Be Uv Transparent.• Lid And Cables Should Be Separate And Must Not Be Attached.• Bromophenol Blue Migration Should Be Approx 4-5Cm / H At 90V.• Run Time Should Be 45-60 Min At 90.• Should Include 1 Mm Thick 2 Combs Of 16 Sample Wells.• Buffer Volume Should Not Be More Than 300Ml.• Tank Of The System Should Be Single Moulded To Ensure Leak Proof Buffer Tank. Even The Parts Should Also Be Single Molded That Are Easy To Repair And Replace.• 16 Sample Combs Should Have 16 Μl Sample Capacity In Each Well.• The Electrodes Should Not Be Attached To The Tank And Should Be Cassette Type Electrodes For Easy Repair And Replacement. • Should Have Pure Platinum Wire And Gold Plated Corrosion Resistant Electrodes.• Should Include Casting Dams For Tape Free Casting Of Gels.• Should Include Loading Guides For Easy Identification Of Wells.• Should Have Color Coded Combs Option And Should Have Options For 0.75Mm, 1Mm, 1.5Mm And 2Mm Combs.• It Should Support Widest Range Of Combs To Run Up To 100 Samples.• The Unit Must Have Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use – Part 1: En61010-1: 2001, General Requirements Following The Provisions Of Directives 73 / 23 / Eec ( Low Voltage ) And 89 / 336 / Eec ( Emc ) As Amended By 93 / 68 / Eec ( Ce Marking ) . • Include 7X7cm Gel Traypower Pack:• The Power Pack Should Be From A Reputed Manufacturer.• It Must Have 5-300V, 1-700Ma And 150W With 1V / 1Ma Increment.• Should Be Capable Of Running At Constant Current Constant Voltage.• Power Supply Should Have 5 Pair Of Output To Connect 5 Units All Together In The Same Unit.• It Should Be Programmable To Set Different Programs.• Display Should Be 2.4” Lcd Display.• It Must Include Preset Programs And Must Have 6 Steps With 30 Programmable Files.• Should Have Timer To 999 Minutes And Timer Alarm Too After The End Of Run.• When Target Constant Mode Is Set, The System Automatically Adjusts The Two Other Parameters To Maximum To Allow For A Constant Run.• Safety Feature: No Load Detection, Leakage Detect, Over Load Detection, Over Temperature Protection, &Sudden Load Change Detection.• Operating Temperature 4?~ 40?.• The Unit Must Have Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use – Part 1: En61010-1: 2001, General Requirements Following The Provisions Of Directives 73 / 23 / Eec ( Low Voltage ) And 89 / 336 / Eec ( Emc ) As Amended By 93 / 68 / Eec ( Ce Marking ) .

Key Value

Document Fees
Refer document
EMD
INR 5000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : Establishment of Advanced virus and other pathogens diagnostic and Testing Service Centre for Plant Propagation Materials for the benefit of the Farmers and Entrepreneurs in West Bengal
Sl. No. Item Description
1Plant Growth Chamber with laminar flow : • Chamber Internal capacity should be minimum between 1200 – 1300 ltrs • Temperature range 00C to 400C lights off +50C to 400C lights on or better • Temperature stability +/-0.50C or better • Humidity range: upto 95% lights off & 80% lights on or better • Humidity stability +/- 3% RH or better • Chamber should be supplied water storage tank approx. 15 to 20 litrs for humidity water storage. Humidifiction should be ultrasonic humidification or equivalent for better humidity uniformity • Fluorescent lamps properly located horizontally tier tray which must be adjustable to provide a uniform light intensity throughout the shelf. • Light intensity must be 290 micromoles/m2/s or more per shelve and should be Dimmable from 100% to 10%. Chamber should be supplied with two light try shelves. • Control panel for temperature; humidity and photoperiod with touch screen display with Real time circadian (countdown) programming. Programs can run in ramping or non-ramping or diurnal modes. • There must be provision that chamber should accomodate LED light trays in fututre at no extra cost on hardware but only taking the extra LED light shelf • Air circulation inside the chamber should be from an air diffuser & should travel along the entire back wall over the shelves should be adjustable to plant-specific to ensure uniform transpiration and optimum excahnge of gases • Doors must be reach-in door with magnetic gasket to provide tight seal and with lock & key for each door • Independent High/Low temperature safeties adjustable must be availabe for chamber utilizing an independent sensor. • Chamber interior should be made from corrosion resistant SS or white plastic coated aluminium and exterior should be plastic coated steel. It should have castor wheels for easy mobility. Should be supplied with air cooled refrigeration system with CFC free refrigerants. • It should be operable with single phase, 230V AC & 50 Hz with power less than 2KW and electircal should be IP protected • Internal 1310mm (w) x 675mm (d) x 1410mm (h), External 1440mm (w) x 810mm (d) x 1975mm (h),Volume 1200 litres nominal
2Gel Electrophoresis : Mini Horizontal Electrophoresis: • System should be completely self contained system designed for quick checks of samples. • Gel casting, running and analysis all should be performed in the same unit.• Should have UV transparent base to allow direct viewing on a UV transilluminator. • Gel dimensions should be 10x8cm.• Should have in-built tray with dual comb slots. • Two combs of 1.5mm thickness for 8 samples should be provided with the unit.• Casting dams should also be included for tape free casting. • Buffer volume should not be more than 50ml.• Should be able to run maximum of 40 samples. • Option for multichannel compatible combs.• The unit must have Safety Requirements for Electrical Equipment for measurement, Control, and Laboratory Use – Part 1: EN61010-1: 2001, General requirements Following the provisions of Directives 73/23/EEC (Low Voltage) and 89/336/EEC (EMC) as amended by 93/68/EEC (CE Marking). MSMIDI10 Horizontal Electrophoresis: • The horizontal electrophoresis unit must include 10X10cm tray.• Gel Trays should be UV transparent.• Lid and cables should be separate and must not be attached. • Bromophenol Blue migration should be approx 4-5cm/h at 90V.• Run time should be 45-60 min at 90.• Should include 1 mm thick 2 combs of 16 sample wells. • Buffer volume should not be more than 300ml.• Tank of the system should be single moulded to ensure leak proof buffer tank. Even the parts should also be single molded that are easy to repair and replace. • 16 sample combs should have 16 µl sample capacity in each well.• The electrodes should not be attached to the tank and should be cassette type electrodes for easy repair and replacement. • Should have pure platinum wire and gold plated corrosion resistant electrodes.• Should include casting dams for tape free casting of gels. • Should include loading guides for easy identification of wells.• Should have color coded combs option and should have options for 0.75mm, 1mm, 1.5mm and 2mm combs. • It should support widest range of combs to run up to 100 samples. • The unit must have Safety Requirements for Electrical Equipment for measurement, Control, and Laboratory Use – Part 1: EN61010-1: 2001, General requirements Following the provisions of Directives 73/23/EEC (Low Voltage) and 89/336/EEC (EMC) as amended by 93/68/EEC (CE Marking). • Include 7x7cm gel tray Power Pack:• The power pack should be from a reputed manufacturer.• It must have 5-300V, 1-700mA and 150W with 1V/1mA increment.• Should be capable of running at constant current constant voltage. • Power supply should have 5 pair of output to connect 5 units all together in the same unit. • It should be programmable to set different programs.• Display should be 2.4” LCD display.• It must include preset programs and must have 6 steps with 30 programmable files. • Should have timer to 999 minutes and timer alarm too after the end of run.• When target constant mode is set, the system automatically adjusts the two other parameters to maximum to allow for a constant run. • Safety Feature: No Load detection, Leakage detect, Over load detection, Over temperature protection, &Sudden load change detection. • Operating temperature 4?~ 40?.• The unit must have Safety Requirements for Electrical Equipment for measurement, Control, and Laboratory Use – Part 1: EN61010-1: 2001, General requirements Following the provisions of Directives 73/23/EEC (Low Voltage) and 89/336/EEC (EMC) as amended by 93/68/EEC (CE Marking).