Tender For Ioaod Eng Development Of New A Site Ro At Heningkunglwa Village, Nh 129A, Dist. Peren, Nagaland., Dimapur-Nagaland

Indian Oil Corporation Limited-IOCL has published Tender For Ioaod Eng Development Of New A Site Ro At Heningkunglwa Village, Nh 129A, Dist. Peren, Nagaland.. Submission Date for this Tender is 06-02-2023. Land Development Tenders in Dimapur Nagaland. Bidders can get complete Tender details and download the document.




Tender Notice

35657142
Tender For Ioaod Eng Development Of New A Site Ro At Heningkunglwa Village, Nh 129A, Dist. Peren, Nagaland.
Open Tender
Indian
Nagaland
Dimapur
06-02-2023

Tender Details

Ioaod Eng Development Of New A Site Ro At Heningkunglwa Village, Nh 129A, Dist. Peren, Nagaland.

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
INR 3.02 Crore /-

BOQ Items

Name of Work:Development of New "A" Site RO at Location "Heningkunglwa Village on NH - 129", Dimapur, Nagaland
Sl. No. Item Description
1LAND DEVELOPMENT
2Clearing grass and removal of the rubbish outside site premises and at an unobjectionable place.
3Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth within premises
4TRANSPORTATION AND INST OF TANKS
5Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
6iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm)
7Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete.
8i) Local Fine Sand within grading zone IV
9Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
10Installation of supplied 20 KL Tank as per specified drawings as per work description but excluding all works of kerb wall and Gasket for manhole including painting / doping with Shalimastic HD as applicable as per specifications complete.
11vi) In brick masonry pit with RCC matt under driveway including RCC top slab as per standard Drg. ENG/318. Manhole cover plates and frame to be paid separately. (with sand filling)
12Supply and installation of screwed type gun metal valves as per IOC specifications: Angular Check Valve
13i) S/I Screwed type GM Angular Check Valve of 50 mm dia
14Supplying and installation of the following threaded Caps conforming to detailed specification
15i) S/I of Threaded caps of 50 mm dia for dip pipe
16ii) S/I of Threaded caps of 80 mm dia.for fill pipe
17Supplying and installation of the following threaded coupling
18i) 80 mm dia Aluminium camlock coupling - Male only
19Supply and installation of ‘U’ type CS bend on the vent pipes including painting as per specifications and supplying and brazingwire mesh of 11 mesh per linear centi-meter of non-corrosive metal in two layers on both ends.
20i) Supply & installation of U type CS bend on vent pipe of 80 mm dia
21Providing stainless steel wire mesh 32 SWG, 11 mesh per linear cm of of non corrosive metal in two layers on existing vent hoods ‘U’ type (on both ends) including brazing, etc. complete
22i) 32SWG SS wire mesh both sides of existing U vent hood 80mm dia
23Supply and fixing Pressure Vacuum Valves of 2 inches for fixing to the Vent Pipes of Underground MS tanks. The valve should be in closed position at normal operating pressure of the tank. The Valve shall be capable for activation at set pressure of 3" ± 0.5 water column to release excess pressure of tank to the atmosphere and open at vacuum of 8" ± 2.0 water column to induce the atmosphere pressure to the tank. PV valve should be diaphragm of dead weight or spring loadedtype or combination of any. The weight of the PV valve shall not exceed 2.0 kg. top of the valve shall be provided with cover/cap/ weather hood to prevent the entry of rain water. Valve material,Coverand adopter shall be of Aluminium/polypropylene, diaphragm if used should be of Neoprene, O ring should be of rubber/neoprene, Net/Mesh Pressure puppet ,Vacuum puppet,screws and spring should be of stainless steel. Suitable adopter with one end fitted with valve and the other end should have threading for fixing on Vent pipe of 40mm. PV valves shall have: UL 842 certification of CARB approval or test certificate from any Govt.lab. PV valve shall have PESO approval.
24Transportation of equipmentfrom one location to another location including enroute all taxes, leviesand unloading/loading by a suitable vehicle exclusively for this purpose (In case of tank sameshall be loaded by the tank fabricationcontractor)
25iii) 15/20 KL Tank with fittings : 0 - 30 Km
26iv) 15/20 KL Tank with fittings: Add extra for each addtnl. Km above 30km
27Providing and fixing of square composite (FRP) Manhole Cover with frame D400 with 40T load bearing capacity, all complete and as per drawing, specification and direction of Engineer-in-charge. Note: Diameter would be clear opening of cover.
28iii) 900 X 900 mm
29CONST.OF PUMP PLINTH, INSTALLATION OF PU
30Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
31i) All kinds of Soil
32Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete.
33i) Local Fine Sand within grading zone IV
34Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth
35Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
36iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm)
37Centering and shuttering including strutting, propping etc. and removal of form for :
38i) Foundations,footings,bases of columns, etc. for mass concrete
39Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
40ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
41viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH
42Providingandfixing18mmthickgangsawcutmirrorpolished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels.
43iv) Granite of any colour and shade having Area of slab over 0.50 sqm
44Supply and Laying of 80 mm dia single wall flexible piping system comprising of Non-metallic HDPE (flexible) pipelines as per IOCL specifications and with manufacturer supplied fittings including all bends, tees, elbows, reducers, end connectors at DU & tank side etc and as required for complete underground piping job. The joints in the pipelines, except the end connections at tanks and dispensers shall be made by electro-fusion welding. The pipes shall be suitable for use with petroleum and ethanol blended fuels. The maximum operating pressure shall be 7Kg/sq.cm. Note: The make of HDPE Pipe should be CCOE approved. Pressure testing shall be done before the final backfilling. The civil works for installation viz. excavation, sand filling& back filling etc. shall be paid seperately. All metallic parts in the piping system shall be grounded as per the requirements of EN14125.
45Supply and Laying of 50 mm dia single wall flexible piping system comprising of Non-metallic HDPE (flexible) pipelines as per IOCL specifications and with manufacturer supplied fittings including all bends, tees, elbows, reducers, end connectors at DU & tank side etc and as required for complete underground piping job. The joints in the pipelines, except the end connections at tanks and dispensers shall be made by electro-fusion welding. The pipes shall be suitable for use with petroleum and ethanol blended fuels. The maximum operating pressure shall be 7Kg/sq.cm. Note: The make of HDPE Pipe should be CCOE approved. Pressure testing shall be done before the final backfilling. The civil works for installation viz. excavation, sand filling& back filling etc. shall be paid seperately. All metallic parts in the piping system shall be grounded as per the requirements of EN14125.
46Supply, fabrication, laying and testing of MS, BLACK, ERW, threaded pipes, heavy class conforming to IS 1239, PART I as per IOCL Specifications including pipeline fittings like bends, tee etc as required and as directed for Above Ground pipeline including surface preparation according to standard SSPC ST2 and painting with 2 coats of red oxide zinc phosphate primer and 2 coats of Synthetic enamel / aluminium finish paint as per IOCL specifications
47iv) S/L Threaded A/G HD MS Pipes of 40 mm dia with fittings,Painting
48Transportation of equipmentfrom one location to another location including enroute all taxes, leviesand unloading/loading by a suitable vehicle exclusively for this purpose (In case of tank sameshall be loaded by the tank fabricationcontractor)
49vii) Mono/Duo pump/Air Comp/STP/All other pumps - upto 2 nos,0-30 Km
50viii) Mono/Duo pump/Air Comp/STP/All other pumps - upto 2 nos, Add extra for every additional Km above 30km
51Installation of supplied Multi Product Pumps / Dispensers on pump island as per manufacturers installation manual, drawings, including supplying, providing necessary frame of ISMC 100, foundation bolts, supplying and filling required quantity of dry sand in pit(s) below the pump
52i) 2 product - 4 nozzle MPPs/MPDs
53Supply & welding slip-on flanges conforming to IS2062 GrA, ANSI B16.5, Class#150 with 3 runs of weld outside and one run of weld inside the flanges as per specifications and standard Drg.enclosed herein
54iii) S/W Slipon flanges of 50 mm dia. conforming to IS2062 GrA, ANSI B16.5,Class 150 as per specifications and standard Drg.enclosed herein
55CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
56iii) 3 Core x 1.5 sq. mm. (copper)
57iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
58CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compressoncable glands, crimping type lugs and allied jointing materials, etc. all complete as per specificationand direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
59vii) 3 Core x 2.5 sq. mm
60Supply of chemical earthing technology (pipe in pipe) for Electrode Design of specified Current Carrying Capacity in kA for 1 second. Crystaline Conductive mixture which is machine pressed in the pipes should not disintegrade or collapse when the outer pipe corrodes. Resistivity of the Material shall be less than 0.2ohm meter when tested by making a 20cm Cube of the Material & checking the resistance across the opposite faces of the cube. Necessary Test certificate shall be submitted. Concentric Earth Electrode Pipe should be MS of IS:1239 quality & hot Dip galvanised of 150 micron. Electrode Material Selection should be as per Clause 9.3: IS-3043.
61ii) Current Capacity:15kA Primary Conductor(Inner pipe dia-20NB; Electrode Outer Pipe Dia-40NB Length of Concentric Pipes:3M
62Supply & drawing/laying, jointing, connecting, testing and commissioning ofearth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following :
63i) 50 x 10mm G.I. Strip
64ii) 32 x 6 mm G.I.strip
65v) 25 x 3 mm GI strip
66x) 8 S.W.G. Cu. Wire
67MINIATURE CIRCUIT BREAKERS (MCB) Supplying & fixing of Miniature Circuit Breakers as per approved make of 10KA Breaking cpacity of following ratings
68ii) 6A to 32A SPN MCB
69MCB DISTRIBUTION BOARD INCLUSIVE OF SINGLE PHASE MCB Supply & fixing of MCB Distribution Board double door type, IP-42, inclusiveof MCB, Single Phase, as per approved make of following types with all accessories such as tinned copper busbars, neutral link, earth bar, din bar, knockouts, interconnections, earth studs, etc. (MCB - 10KA Breaking Capacity)
70ii) 12 way DB with 32A DP as incoming-1No.& 6to16ASP as outgoing-12No
71iii) Supply and fixing of shock treatment chart in English, Hindi & local language framed in glass framework.
72Providing & fixing flexible copper cable PVC insulated of 16sqmm for connecting the earth grid/earth strip with the crocodile clip i/c cost of 1 no. crocodile clip (for tanker earthing & other job)
73THREE PHASE SERVO STABILIZER Supplying and fixing of 3 phase air cooled servo stabilizer for balanced and unbalanced load shall be independent correction of each phase (Range 300 - 460 V minimum) and as per specification
74v) 30 KVA stabilizer
75CONSTANT VOLTAGE TRANSFORMER Supplying, installation, testing and commissioning of single phase, air cooled constant voltage transformer of approved make having input voltage range of 180-260V and output voltage of 220/230V with sine wave output wave form and having automatic current limiting and short circuit protectionincluding all accessories complete (for displays) for the following VA ratings.
76iii) 500VA CVT
77CONSTRUCTION OF BUFFER STRIP
78Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
79i) All kinds of Soil
80Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete.
81i) Local Fine Sand within grading zone IV
82Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth
83Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
84iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm)
85Centering and shuttering including strutting, propping etc. and removal of form for :
86i) Foundations,footings,bases of columns, etc. for mass concrete
87Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level
88ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
89Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
90ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
91Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
92ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
93Providing and laying cement plaster on surfaces with fine sand including curing etc.
94i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)
95Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
96CONSTRUCTION OF RCC CULVERT AND OPEN DRAIN
97Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
98i) All kinds of Soil
99Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth
100Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level
101ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
102Centering and shuttering including strutting, propping etc. and removal of form for :
103i) Foundations,footings,bases of columns, etc. for mass concrete
104Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
105ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
106Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
107ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
108Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
109Providing and laying cement plaster on surfaces with fine sand including curing etc.
110i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)
111Providing Neat cement punning
112Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes.
113ii) 110 mm diameter
114CONSTRUCTION OF LGSF SALES BUILDING
115Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
116i) All kinds of Soil
117Supply & filling of local earth (including royalty) by mechanical transport also including ramming & watering of the earth in layers not exceeding 20cm in depth in plot, trenches, plinth, sides of foundations etc. complete
118Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete.
119i) Local Fine Sand within grading zone IV
120Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). Item includes providing & mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer"s specifications. Providing & applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil
121Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth
122Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level
123ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
124Centering and shuttering including strutting, propping etc. and removal of form for :
125i) Foundations,footings,bases of columns, etc. for mass concrete
126iv) Lintels, beams plinth beams,girders bressumers and cantilevers
127v) Columns, Pillars, Piers, Abutments, Posts and Struts.
128Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
129ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
130Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
131ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
132Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
133Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Tiles of dark shade pigment using ordinary cement
134Providing and placing on terrace (at all floor levels) polyethylene water storage tank IS : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
135Design, Fabrication, Supply, Transportation, Erection and Mechanical, Electrical & Plumbing works including loading & unloading of LGSF Sales Building of following sizes:
136LGSF Size : 7.5M x 4.0M (GF) - Opt1 -N
137CONSTRUCTION OF SEPTIC TANK & SOAK PIT
138Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
139i) All kinds of Soil
140Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth
141Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level
142ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
143Centering and shuttering including strutting, propping etc. and removal of form for :
144iii) Suspendedfloors,roofs,landings,balconies, access platform and Shelves (Cast in situ)
145Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
146ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
147Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
148ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
149Providing and laying cement plaster on surfaces with fine sand including curing etc.
150i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)
151Providing Neat cement punning
152Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
153viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH
154ELECTRIFICATION OF SALES BUILDING
155PANEL BOARDS AND DISTRIBUTION BOARDS Supply, installation, testing and commissioning of cubicle type power and motor control centre panel fabricated out of 14 SWG sheet steel undergone 7 tank process,dust & vermin proof, floor mounting type, suitable for indoor use having cable entry from the bottom and having following specific components complete, control wiring etc. as per enclosed standard drawing. Any other components/hardware required to complete the panels but not mentioned here shall also be provided. Note: Both incomers should have mechanical interlock for proper & safe operation. The MCCB used for incomer feeder shall have short circuit, overload and earthfault protection and also shunt coil for ESD operation. The Bus Bar support shall be DMC/ SMC/Epoxy moulded. All equipment/components shall be mounted logically to have free access for maintenance, tightening of connections & visual inspection. All the metering equipment shall be Digital & mounted on the panel and size of meter shall be 96 mm x 96 mm. The Bus Bar shall be provided with heat shrunk PVC sleeves & all power terminals shall be stud type with properly shrouding to avoid accidental contact. Neoprene type gasket shall be provided at the doorof the panel. The enclosure of the Panel shall have IP52 degree of protection. 2 Nos earth terminal shall be provided at the Panel frame with extension link for earthing connections. Painting:The under surface shall be prepared by applying a coat of phosphate paint and coat of yellow zinc chromate primer. The under surface shall be made free from all imperfections before undertaking the finishing coat. After preparation of the under surface, the switchboard shall be spray painted with two coats of epoxy based final paint or shall be powder coated. Colour shade of final paint shall be RAL 7032.
156Medium RO, Standard drawing No. ENG/IOCL/PDIL-2. List of Componets are: (a) 1 No. MCCB (3P+N) of 100 A, 35 KA with O/L, E/F & S/C Releases for incomer from Electricity Board (b) AC Digital Voltmeter (0-500V) with built in selector switch for incomer from Electricty Board (c) AC Digital Ammeter (0-100A) with built in selector switch for incomer from Electricity Board (d) 1 No. FP, On Load, 100 A, Manually Operated Change over switch suitable for connection of Mains supply and 30 KVA DG Set /5 KW Solar system with required No. of MCCB (100 A,35 KA,3P+N) for change over between Mains supply and DG Set /Solar Supply along with 2 Nos 6A , SP, Control MCB with Indicating lamps. (e) 1 No. MCCB (3P+N) of 100A, 35 KA with UV coilO/L , E/F & S/C Releases for incomer from Electricity Board/DG Set/Solar Supply & 1 No 6A , SP, Control MCB with 3 Nos LED Type (RYB) Indicating lamps (f) 3 Nos 100/5 A CL1 10VA Current Transformers ; PT (50 VA) along with 2 A control fuse link and 1 No. 6A , SP, Control MCB (g) 1 No DP MCB of 40 A, 10 KAfor supply of essential loads (h) 1 No Single Phase Contactor(3NO+3NC) for supply to essential loads (i) 1 No MCB DB Hosuing 6 Nos , 16 A, 10 KA DP MCB as outgoings for essential loads (j) 415 V, TP & N, 125 A, Al Bus Bar (k) 4 Nos MCB (3P+N) of 40 A,10 KA for supply of outgoing feeders 1-4 (l) 9 Nos DP MCB of 10 A, 10 KA in Outgoing Feeder -1 (m) 6 Nos DP MCB of 16 A, 10 KA & 3 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-2 (n) 3 Nos DP MCB of 16 A, 10 KA & 6 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-3 (o) 8 Nos TP MCB of 16 A, 10 KA & 1 Nos TP MCB of 25 A, 10 KA in outgoing Feeder-4 (p) Provision for Termination of Solar Power (Up to 10 KW) Incomer to Essential DB in Panel as per requirement ofIOCL.
157SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved includingflush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer"s specification and direction of Engineer In-charge.
158iii) 4 module frame
159viii) 15 A Modular switch
160xi) 2 Pin Telephone Modular Socket
161xii) Fan Regulator of stepped modular type
162Supply & fixing of 30mA RCCB of approved Make of following ratings:
163v) 4 poles, 63A
164Supplying & fixing of approved make 4 pole change over switch in steel sheet enclosure with side handle operation onload type grouting in C.C. Complete as per direction of Engineer-In-Charge.
165iii) 100 Amps., 4 Pole
166MCB DISTRIBUTION BOARD INCLUSIVE OF 3- PHASE MCB Supply & fixing of MCB Distribution Board double door type inclusive ofMCB, Three Phase, as per Approved Make of following types: (MCB - 10KA Breaking Capacity)
167iv) S/E 12 way DB with 63A FPRCBO, 300 mA sensitivity as incoming- 1 No.& 6 to 16A SP as outgoing - 12 Nos. for each phase.
168Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watt, having IP65 protection class with Pressure Die Cast Aluminium housing & with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. The LED shall be operating under voltage range of 140-270V with power factor more than 0.9. CCT(Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), CRI (Colour rendering index) not less than 65. LED efficacy should be minimum 100 lumens/watt. The driver shall be of constant volt & constant current type with internal surge protection. Each lot of Fittings shall have serial numbers and accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc.
169Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 8 Watt, having IP20 protection class with Pressure Die Cast Aluminium housing & with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. The LED shall be operating under voltage range of 140-270V with power factor more than 0.9. CCT(Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), CRI (Colour rendering index) not less than 65. LED efficacy should be minimum 100 lumens/watt. The driver shall be of constant volt & constant current type with internal surge protection. Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports & reference/batch nos of LEDs & fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc.
170CEILING FANS Supply & fixing of ceiling fan for inside of the sales building of following type:
171iii) 1200 mm sweep
172EXHAUST FANS Supply and fixing of exhaust fan including electrical wiring all shall be with per specification and direction of site In charge. The fans shall be with louvers / shutters. (The job does notinclude making suitable cut out in thewall for fixing the fan).
173ii) 9" dia light duty, make Khaitan or equivalent
174Supplying and fixing of MV Lightining Arrestor horn gap type as required
175Formation of lighting protection arrangement with supply of 1.0 M height spike and erection at top most portion of structure/building and connecting the same to earthpit by 40x6mm GI strip (excluding supply and laying of GI strip)
176Providing and fixing of square composite (FRP) Manhole Cover with frame D400 with 40T load bearing capacity, all complete and as per drawing, specification and direction of Engineer-in-charge. Note: Diameter would be clear opening of cover.
177i) 450 X 450 mm
178ii) 600 X 600 mm
179iii) 900 X 900 mm
180CONSTRUCTION OF PRE-FAB MODULAR TOILET
181Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
182i) All kinds of Soil
183Supply & filling of local earth (including royalty) by mechanical transport also including ramming & watering of the earth in layers not exceeding 20cm in depth in plot, trenches, plinth, sides of foundations etc. complete
184Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete.
185i) Local Fine Sand within grading zone IV
186Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). Item includes providing & mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer"s specifications. Providing & applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil
187Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth
188Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level
189ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
190Centering and shuttering including strutting, propping etc. and removal of form for :
191i) Foundations,footings,bases of columns, etc. for mass concrete
192iv) Lintels, beams plinth beams,girders bressumers and cantilevers
193v) Columns, Pillars, Piers, Abutments, Posts and Struts.
194Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
195ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
196Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
197ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
198Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
199Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Tiles of dark shade pigment using ordinary cement
200Providing and placing on terrace (at all floor levels) polyethylene water storage tank IS : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
201Design, Fabrication, Supply, Transportation, Erection and Mechanical, Electrical & Plumbing works including loading & unloading of Modular PEB (Porta Cabin) (7.0 mtr x 3.0 mtr)
202AIR FACILITY
203Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
204i) All kinds of Soil
205Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth
206Centering and shuttering including strutting, propping etc. and removal of form for :
207i) Foundations,footings,bases of columns, etc. for mass concrete
208Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
209v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm)
210ii) 1:1½:3(1 Cement :1½ Coarse Sand: 2 Graded stone aggregate of 20mm)
211Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
212i) Brick work in Cement mortar 1:4 (1 cement : 4 coarse sand)IN FOUNDATION AND PLINTH
213Providing and laying cement plaster on surfaces with fine sand including curing etc.
214i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)
215Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete.
216i) Local Fine Sand within grading zone IV
217Providingandfixing18mmthickgangsawcutmirrorpolished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels.
218iii) Granite of any colour and shade having Area of slab upto 0.50 sqm
219Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
220Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
221Providingandfixingmachinemouldedaluminiumcovering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceilings, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick & 15 mm dia, at a staggered pitch of 200 mm centre to centre including drilling holes in the receiving surface and expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-charge.
222ii) Powder coated aluminium sheet 2.5mm thick(minimum thickness of powder coating 50 micron)
223Air compressor Supply and installation of horizontal air compressor assembly with delivery pressure of 12 kg/sq cm equipped with pressure gauge, non- return/safety/drain/delivery valves, automatic cut-off switch and suitable electrical connections & all standard accessories, including civil works:
224ii) Horizontal air compressor Assembly of 3 HP (160-220 LITRES) including civil works
225Tyre Inflator Supply & installation of Digital tyre inflator which is microprocessor based, automatic air pressure controller with solenoid controlled nozzle for automatic fill and release functions. Complete with weather proof cabinet, 3 digit LED displays with backlight illuminations i.e. one for actual tyre pressure and another for set pressure. Air filter, remote controller, cables, PVC hose pipe and working pressure upto 10bar (Excluding civil work for foundation,etc.)
226CONSTRUCTION OF DRIVEWAY & APPROACHES
227Centering and shuttering including strutting, propping etc. and removal of form for :
228i) Foundations,footings,bases of columns, etc. for mass concrete
229Construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mixer plant at Optimum Moisture Content, carriage of mixed material by tippers to work site, for all lead and lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface & compacting with vibratory power roller to achieve the desired density, complete as per specification & direction of Engineer-in-charge.
230i) With material confirming to grade-I (size 75 mm to .075 mm) having CBR value - 30, Thickness as desired
231Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to .075 mm) to wet mix macadam (WMM) specifications including premixing the material with water at OMC for all leads and lifts, laying in uniform layers with mechanical paver finisher in sub-base/base course on well prepared surface and compacting with vibratory roller of 8 to 10 ton capacity to achieve the desired density, complete as per specifications & directions of Engineer-in- charge
232Providing & laying factory made reflective type Lacquered finish Grey / coloured pre-cast cement concrete, interlocking paver block of specified grade made by block making machine wih vibratory compaction & of approved size and design / shape, shade and manufacturers and as per IOCL"s specifications. The paver blocks shall have peripheral chamfer, with average crushing strength as per IS 15658, maximum water absorption of 2% after 10 minutes and 5% after 24 hrs. as per BS 1881, maximum dimensional deviations of +/- 2mm on length @ width and +/- 3 mm on thickness. The job includes supplying and laying a layer of 50 mm thick clean coarse sand on thoroughly compacted sub-base below the paver blocks, cutting the paver blocks wherever required with hydraulic splitter, filling in the joints at the edges of paver blocks with sand, compacting with machine vibrator to required line and level, etc. complete. (Payment for provision of edge restraints shall be made separately)
233ii) M40 grade 80 mm thick reflective type Lacquered finish
234Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level
235ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
236Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
237ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
238Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement:3 coarse sand) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment) (Precast C.C. kerb stone shall be approved by Engineer-in-charge.
239SUPPLY AND INSTALLATION OF YARD LIGHTS
240Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes.
241iii) 160 mm diameter
242ii) 110 mm diameter
243Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
244iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm)
245CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
246i) 2 Core x 1.5 sq. mm. (copper)
247iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
248xviii) 3.5 Core x 50 sq. mm Aluminium Cable FRLS
249CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compressoncable glands, crimping type lugs and allied jointing materials, etc. all complete as per specificationand direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
250ii) 2 Core x 2.5 sq. mm
251vii) 3 Core x 2.5 sq. mm
252Supply & drawing/laying, jointing, connecting, testing and commissioning ofearth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following :
253v) 25 x 3 mm GI strip
254OCTAGONAL POLES Supply & Fixing of Octagonal Poles of following type (Civil job shall be paid separatly) :
255iii) S/E of 5 Meter high galvanised Octagonal pole with top 60mm(A/F), bottom 130mm (A/F) made up of 3 mm thick plate having a base plate of size 210 x 210 x 12 with single arm 1500mm long bracket arm made up of 48 O.D. pipe with EN 8 grade galvanised foundation bolts and anchor plate on suitable concrete foundation as per standard drawings enclosed herein(Civil & Electrical works shall be paid separately) having fixing arrangement for mounting 2 Nos. of 250W Metal halide luminaries (on opposite sides)
256i) S/E of 7 Meter high galvanised Octagonal pole with top 70mm (A/F), bottom 130mm (A/F) made up of 3 mm thick plate having a base plate of size 220 x 220 x 12 with single arm 1500mm long bracket arm made up of 48 O.D. pipe with EN 8 grade galvanised foundation bolts and anchor plate on suitable concrete foundation as per standard drawings enclosed herein(Civil & Electrical works shall be paid separately) having fixing arrangement for mounting 2 Nos. of 250W Metal halide luminaries (on opposite sides)
257Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
258Supplying & drawing inside the poles 3 core 2.5 sq.mm PVC insulated flexible copper conductor, fixing of junction box at the pole base (excluding supply of JB), making all connections on both ends, all complete as per specification and direction of Engineer In-charge.
259ii) "L" Pole
260Supply and fixing of 100 W LED (Light Emitting Diode) light fixture with fittings and accessories for Yard lighting purpose having IP66 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc.
261Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
262i) All kinds of Soil
263Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth
264Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level
265ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
266Centering and shuttering including strutting, propping etc. and removal of form for :
267i) Foundations,footings,bases of columns, etc. for mass concrete
268Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
269ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
270CONSTRUCTION OF MONOLITH FOUNDATION
271Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
272i) All kinds of Soil
273Extra for every additional lift of 1.5m or part thereof in excavation or banking excavated or stacked materials in all kinds of soil
274Supply & filling of local earth (including royalty) by mechanical transport also including ramming & watering of the earth in layers not exceeding 20cm in depth in plot, trenches, plinth, sides of foundations etc. complete
275Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth
276Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level
277ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
278Centering and shuttering including strutting, propping etc. and removal of form for :
279i) Foundations,footings,bases of columns, etc. for mass concrete
280Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
281ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
282Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
283viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH
284Providingandfixing18mmthickgangsawcutmirrorpolished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels.
285iii) Granite of any colour and shade having Area of slab upto 0.50 sqm
286Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes.
287ii) 110 mm diameter
288Providing and laying cement plaster on surfaces with fine sand including curing etc.
289i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)
290Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Standards and as approved by Engineer-in-charge :
291v) 25mm dia x 1000mm long with 100 mm dia x 8 mm thick plate
292CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
293xxiv)3 Core x 2.5 sq. mm Copper Cable XLPE
294CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compressoncable glands, crimping type lugs and allied jointing materials, etc. all complete as per specificationand direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
295vii) 3 Core x 2.5 sq. mm
296Providingand laying class-B 50mm dia GI pipe for cable routing under flooring/ EB post leading including sealing both ends with jute and Bitumen
297Supply & fixing of weatherproof125 mm dia junction box (4 way entry) of BALIGA/CEAG-FCG/FLEXPRO/FEPL makeincluding clamping arrangement, all complete as per specification & direction of Engineer In-charge.
298Supplying and fixing of following MCBs with necessery inter connectionson existing DB, Panel board etc.
299ii) Upto 32A DP MCB
300CONSTRUCTION OF ONE DOUBLE SIDED HOARDING
301Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
302i) All kinds of Soil
303Supply & filling of local earth (including royalty) by mechanical transport also including ramming & watering of the earth in layers not exceeding 20cm in depth in plot, trenches, plinth, sides of foundations etc. complete
304Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth
305Providing & laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc. UP TO FLOOR V LEVEL excluding the cost of centering, shuttering and finishing :
306ii) PCC 1 Cement:1½ Coarse Sand:3 Graded Stone Aggregate 20mm
307Providing and laying cement plaster on surfaces with fine sand including curing etc.
308i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)
309Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
310Painting on G.S. sheet with synthetic enamel paint of approved brand & manufacture of required colour to give an even shade, 2 or more coats,including a coat of approved steel primer but excluding a coat of mordant solution
311Centering and shuttering including strutting, propping etc. and removal of form for :
312v) Columns, Pillars, Piers, Abutments, Posts and Struts.
313Providingand laying class-B 50mm dia GI pipe for cable routing under flooring/ EB post leading including sealing both ends with jute and Bitumen
314Supplying and fixing of following MCBs with necessery inter connectionson existing DB, Panel board etc.
315ii) Upto 32A DP MCB
316CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compressoncable glands, crimping type lugs and allied jointing materials, etc. all complete as per specificationand direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
317vii) 3 Core x 2.5 sq. mm
318CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
319iv) 3 Core x 2.5 sq. mm Copper Cable FRLS
320CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
321i) 2 Core x 1.5 sq. mm. (copper)
322Supply & drawing/laying, jointing, connecting, testing and commissioning ofearth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following :
323vi) 8 S.W.G. G.I. Wire (bare)
324Providing, fixing, testing and commissioning of FLPjunction box of approved make for cable connection/ jointing.
325i) For cables 2.5 to 4 sqmm XLPE / AYFY
326Supply and installation of MCB distribution boardhaving Doubledoorcomplete with tinned cu bus bar, neutral bus bar, earth bar, din bar, interconnection, earthing etc. withoutincoming isolator and MCBs
327ii) 2+8 way SPN
328Supply and fixing of 100 W LED (Light Emitting Diode) light fixture with fittings and accessories for Yard lighting purpose having IP66 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc.
329CONSTRUCTION OF SINGLE SIDE DRAIN
330Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
331i) All kinds of Soil
332Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth
333Centering and shuttering including strutting, propping etc. and removal of form for :
334i) Foundations,footings,bases of columns, etc. for mass concrete
335Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
336ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
337Providing and laying cement plaster on surfaces with fine sand including curing etc.
338i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)
339Providing Neat cement punning
340Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
341iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm)
342CONSTRUCTION OF BOUNDARY WALL
343Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
344i) All kinds of Soil
345Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth
346Centering and shuttering including strutting, propping etc. and removal of form for :
347i) Foundations,footings,bases of columns, etc. for mass concrete
348v) Columns, Pillars, Piers, Abutments, Posts and Struts.
349Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth
350ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
351Providing and laying cement plaster on surfaces with fine sand including curing etc.
352i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand)
353Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
354iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm)
355Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level
356ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
357Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
358ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
359Finishing walls with Acrylic Smooth exterior paint of required shade (2 or more coat applied @ 1.67 ltr/10 sqm over & including priming coat of exterior Primer applied @ 2.20kg/10 sqm)
360CONSTRUCTION OF CANOPY - 17M X 11M
361Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600
362i) All kinds of Soil
363Supply & filling of local earth (including royalty) by mechanical transport also including ramming & watering of the earth in layers not exceeding 20cm in depth in plot, trenches, plinth, sides of foundations etc. complete
364Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth
365Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level
366ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm
367Centering and shuttering including strutting, propping etc. and removal of form for :
368i) Foundations,footings,bases of columns, etc. for mass concrete
369Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels
370ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786
371Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
372Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen= 2100lm.Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc
373Providing and fixing  Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of Cold rolled steel confirming to IS:513-2008 of base metal thickness 0.50 mm, having Yield Stress of Min. 275 MPa. Steel surface shall have hot dip metallic coating of Al-Zinc alloy comprising 55% Alluminium, 43.5% Zinc and 1.5% Silicon as per the ASTM-A792M, with total mass of coating on both sides shall be 150 gms/sqm. The steel shall have organic coating with Silicon Modified Polyester (SMP) /Super Durable Polyester (SDP) paint on continuous coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns SMP /SDP paint over 5-7 microns epoxy primer) and back side 8-10 Microns SMP/SDP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.58 MM. Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m or as desired by Engineer-in-charge.
374i) Profile Sheet for roofing
375ii) Plain Sheet for Ridges (500 - 600mm).
376iii) Plain sheet for Flashings/ Aprons (Upto 600 mm)
377iv) Plain Sheet for Gutter (600 mm over all girth)
378Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes.
379ii) 110 mm diameter
380Providing and fixing  150F/200F flush panel,(pre-coated steel) False Ceiling made of  Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa & 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continuous coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of  thickness of 25 microns minimum to avoid scratches while transportation & should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure.
381Constructing masonry Chamber 60x60x75 cm,inside in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valves etc, with CI surface box 100mm. top diameter,160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominalsize), i/c necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement:3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S (non modular) bricks of class designation 7.5
382Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty
383ii) 150 mm dia. R.C.C. pipe
384iv) 300 mm dia. R.C.C. pipe
385Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Standards and as approved by Engineer-in-charge :
386v) 25mm dia x 1000mm long with 100 mm dia x 8 mm thick plate
387CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items
388xxiv)3 Core x 2.5 sq. mm Copper Cable XLPE
389CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compressoncable glands, crimping type lugs and allied jointing materials, etc. all complete as per specificationand direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used.
390vii) 3 Core x 2.5 sq. mm
391Providing, fixing, testing and commissioning of FLPjunction box of approved make for cable connection/ jointing.
392i) For cables 2.5 to 4 sqmm XLPE / AYFY
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail