Uttar Pradesh Jal Nigam-UPJN has published Tender For Construction Of 1000 Capacity Auditorium Between Mathura And Vrindavan Distt Mathura Material Pcr. Submission Date for this Tender is 16-01-2023. Building Work Tenders in mathura Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

35653082
Tender For Construction Of 1000 Capacity Auditorium Between Mathura And Vrindavan Distt Mathura Material Pcr
Open Tender
Indian
Uttar Pradesh
mathura
16-01-2023

Tender Details

Construction Of 1000 Capacity Auditorium Between Mathura And Vrindavan Distt Mathura Material Pcr Construction Of 1000 Capacity Auditorium Between Mathura And Vrindavan Distt Mathura , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forwiring Points For Light With 1 Sqmm.Fr Pvc Insulated Multistrand Single Core Copper Condutor Cable In Pvc Conduit Pipe Partly Concealed In Wall And Partly Laid In Slab Along With The Reinforcement Before Concreting, Complete With 1.5 Sqmm.Fr Pvc Insulated Multistrand Copper Conductor Cable As Earth Continuity Wire And Piano Type Switch Etc. Complete In All Respects. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forsame As Item No. ( 1 ) But For Two Way Light Points. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forsame As Item No. ( 1 ) But For Fanandlight Duty Exhaust Fan. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forsame As Item No. ( 1 ) But For5 Amp Plug Point , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forsame As Item No. ( 1 ) But Forcall Bell Point , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Foraddition When Modular Type Switches Etc Are Used In Place Of Piono Type Switches Etc. In Various Wiring Points. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Foraddition For Light / Fan Points With Modular Type Switchin Place Of Piono Type Switch. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Foraddition For 2 Way Light Pointswith Modular Type Switchin Place Of Piono Type Switch. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Foraddition For Plugpointswith Modular Type Switchin Place Of Piono Type Switch. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forwiring Of Submain 2 Number 4 Sqmm . Fr Pvc Insulated 1100 V Grade Multistranded Single Core Copper Conductor Cable In Heavy Duty 20Mm Dia Pvc Conduit Partly Concealed In Wall And Partly Laid In Slab Along With One Number 2.5 Sqmm Fr Pvc Insulated Multistranded Copper Conductor Cable As Earth Contunity Wire Etc. Complete In All Respects. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forwiring Of Submain 2 Number 6 Sqmm . Fr Pvc Insulated 1100 V Grade Multistranded Single Core Copper Conductor Cable In Heavy Duty 20Mm Dia Pvc Conduit Partly Concealed In Wall And Partly Laid In Slab Along With One Number 4 Sqmm Fr Pvc Insulated Multistranded Copper Conductor Cable As Earth Contunity Wire Etc. Complete In All Respects. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forwiring Of Submain 2 Number 10 Sqmm . Fr Pvc Insulated 1100 V Grade Multistranded Single Core Copper Conductor Cable In Heavy Duty 25Mm Dia Pvc Conduit Partly Concealed In Wall And Partly Laid In Slab Along With One Number 6 Sqmm Fr Pvc Insulated Multistranded Copper Conductor Cable As Earth Contunity Wire Etc. Complete In All Respects. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forwiring Of Submain 4 Number 10 Sqmm . Fr Pvc Insulated 1100 V Grade Multistranded Single Core Copper Conductor Cable In Heavy Duty 32Mm Dia Pvc Conduitalong With Two Numbers 6 Sqmm Fr Pvc Insulated Multistranded Copper Conductor Cable As Earth Contunity Wire Etc. Complete In All Respects. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forwiring Of Submain 4 Number 16 Sqmm . Fr Pvc Insulated 1100 V Grade Multistranded Single Core Copper Conductor Cable In Heavy Duty 40Mm Dia Pvc Conduitalong With Two Numbers 10 Sqmm Fr Pvc Insulated Multistranded Copper Conductor Cable As Earth Contunity Wire Etc. Complete In All Respects. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixingand Concealing Of20mm Dia.2Mm Thick Pvc Conduit Pipe With Isi Mark Embossed And With Pvc Acessories Confirming To Is No. 3419 For Drawing Wires Duly Sealed At Joints With Original Resin / Adhesive To Make The Complete Piping Rigid, Plastering With Cement Sand Mortar Finished To Level With Matching Colour Including Cost Of Material Etc Required For Proper Completion Of Work . ( For Telephonepoints ) , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forwiring Of Submains With 2 Nos. 2.5 Sq.Mm & With 1 No. Earth Wire Of 1.5 Sq.Mm Fr Pvc Insulated 1100 V Grade Single Core Multistrand Copper Conductor Cable In Existing Pvc Conduit Complete. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forerection And Testing Of Ceiling Fan And Regulator For Room Height Upto 3.5Mts. Including3mm Thick G.I. Down Rod 19Mm Dia Duly Painted, Complete In All Respects. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forerection And Testing Exhaust Fan On The Exhisting Hole With Suitable Size Of Rag Bolts Nuts And Washers Etc. Complete In All Respects. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing Of Hexagonal Fan Box With Hexagonal Side Of Approx 80Mm In Length Fabricated From 16Swgm.S. Sheet Incorporating 10Mm Dia, M.S. Round Barduly Bent For Supporting Fan Hanger Dully Painted Withred Oxide And Screwing Arrangement With Wiring Conduit Laid In The R.C.C. Roof Before Concreting. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixingofelectronic Fan Regulator ( Modular ) 120-280 V. Isimarked, On The Existing Switch Board Including Making Connetion, Required Material, Etc For Proper Completion Of Work To The Satisfaction Of Engineer In Charge Of Work. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing Of Recess Mounting Round 15 To 18 Watt Led Down Lighter Having Powder Coated Die Cast Aluminium Housing With Heat Sink, Diffuser / Reflector And Driver Set Complete In All Respect.Cat- Aaa , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing Of Single Light Wall Bracket On Matching M.D.F.E.G. Board Base Etc. Complete In All Respect.Cat Aaa. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing Of Led Tube Light With Batten Suitable For Up To 1 X 22 Watt Led Tube Light Fitting Including Tube On Surface Complete In All Respect. Cat- Aaa , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing Of Led Tube Light With Batten Suitable For Up To 2 X 22 Watt Led Tube Light Fitting Including Tube On Surface Complete In All Respect. Cat- Aaa , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing Of 36 Watt To 46 Watt Indoor Recess Mounting Led Square Fitting For Armstrong Ceiling Having Powder Coated Die Cast Aluminium Housing Body With Extended Heat Sink And Diffuser Of Special Polycarbonate Meterial And Driver Set Complete In All Respect.Cat-Aaa , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing Of Recess / Surface / Pendent Mounting Round 10 To 15 Watt Led Down Lighter Having Powder Coated Die Cast Aluminium Housing With Heat Sink, Diffuser / Reflector And Driver Set Complete In All Respect. Cat- Aaa , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing Of Factory Wired Integral Led Flood Light Luminaires With Die Cast Aluminium Housing Built With Dirver Set Suitable For 140 To 150 Watt. Confirming To Ip 66 Protection Complete In All Respect.Cat-Aaa , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forsuuply And Fixing Of 17 Watt Led Mirror Light And Complete In All Respect. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forerection Of Recess Mounted Maintained Type Exit Led Light With In Built Battery Pack For Three Hours Duration, Complete In All Respects , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing Of Factory Wired Integral Led Flood Light Luminaires With Die Cast Aluminium Housing Built With Dirver Set Suitable For 40 To 50 Watt. Confirming To Ip 65 Protection Complete In All Respect.Cat-Aaa , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing Of Call Bell Of Approved Make On Matching Polished Mdfeg / Teak Ply Board Including Making Connectionetc. As Required. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing Of Water Tight Oblong 10 Watt Led Bulkhead Luminaire With Driver Set Confirming To Ip 65 And Above Protection . Complete In All Respect. Cat-Aaa , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing Of Flush / Surface Mounting Distribution Boardswithout Mcb With Additional Metal Doorcomplete In All Respects. ( Cat: A ) 12 Way Spn , 4 Way Tpn , 6 Way Tpn , 8 Way Spn , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing And Making Connection Of Following Fpmcbs Complete In All Respects As Per Direction And Satisfaction Of Engineer-In-Charge. 25 Amp. Dp Mcb , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing Of Flush / Surface Mounting Distribution Boardswithout Mcb With Additional Metal Doorcomplete In All Respects. ( Cat: B ) 6 Way Tpn , 4 Way Tpn , 8 Way Spn , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing Of 240 Volts L Series Miniature Circuit Breaker 6 Amp. To 32 Amp. ( 10 K A ) In Existing Mcb, Db Complete With Connections As Required. ( Cat: A ) 6 - 32 Amps. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing And Making Connection Of Following Mcbs Complete In All Respects As Per Direction And Satisfaction Of Engineer-In-Charge. ( Cat: A ) 40 Amp. 4P Mcb ( 10 Ka ) , 63 Amp. Dp Mcb , Supply Of 63 Amp 4P Mcb ( 10Ka ) C Curve. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing Of 40 Amp. 4 Pole Mcb ( 10Ka ) . ( Cat: B ) , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing Of Power Plug With 20A / 250 V Flush Type Modular Switch And 5 Pin 20 A / 250 Volt Flush Type Universal Modular Socket Switch On Concealedm.S. Box. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing Of Power Plug With 15A / 250 V Flush Type Switch And 5 Pin 15 A / 250V Flush Type Universal Socket In Suitable M.S. Box Of 175Mmx100x50mm Size With Phenolic Laminated Bakellite Sheet Cover 3Mm Thick Fixed With Brass Machine Screws And Cup Washer. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixingof Sheet Steel Enclosure Surface / Flush Mounting Fitted With 20 / 32 Amp. 2Pin And Earth Metal Clad Scraping Earth Plug And Socket Complete In Allrespects As Per Direction And Satisfaction Of Engineer-In-Charge. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing Single Pole Mcbs Blanking Plate Complete In All Respects. ( Cat -B ) , Main Distribution Board Supplying Of Material For Surface / Flush Mounting 4 Ways V Tpn Distribution Board With Additional Door Cithout Mcb Complete In All Respect, As Directed At Site By Engineer In Charge. , Supplying Of Material For125 Amp 4P Mccb ( 25Ka ) Thermal Magnetic Release. , Supplying Of Material For40 Amp Tp Mcb ( 10Ka ) C Curve. , Supplying Of Material Forof 63 Amp Tp Mcb ( 10Ka ) C Curve. , Mcb Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing Of 6 Amp. Dp Mcb ( 10Ka ) C Curve. ( Cat: B ) , Supply Ofmodular Boxes, Base & Cover Plate :- Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixingfollowing Size / Modules, Gi Box Along With Modular Base& Cover Plate For Modular Switches In Recess Etc As Required. 1 Or 2 Module ( 75Mm X 75 Mm ) , Supply Of Modular Type Switch / Socket :- Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing Following Modular Switch / Socket On Theexisting Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc As Required. Telephone Socket Outlet , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Fordrawing Telephone Wire Following Pair 0.5 Sqmm Fr Pvc Insulated Annealed Copper Conductor, Unarmoured Telephone Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 2 Pair , Earthing System Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forburying Of 600Mm X 600 Mmx6mm G.I. Plate, Vertically For Earthing With Its Top Atleast 3 Mts. Below Ground Level Complete With 20Mm G.I.Pipe And Funnel For Watering And Two Earthing Leads Of Two No.8To10swg G.I.Wire In 15Mm Diag.I. Pipe Upto Switch Board ( From Apron To Switch Board The Cost Of G.I. Pipe And G.I. Wire Will Be Extra ) 30Cm. Square C.I. Frame With Hinged Cover, Masonary Housing, Alternate Layers / Of Charcoal / Coke And Salt At Least 150Mm Thick Alround Etc. Complete In All Respects. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forlaying Of 25Mm X 3Mm G.I. Strip From Earth Electrode Directly In The Ground. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing Of Two Number 8 Swg G.I. Wire In 15Mm Dia. G.I. Pipe For Earthing, Laid In Ground Or In Wall Duly Concealed Including The Cost Of Cement, Sand, Other Material Required For Proper Completion Of Work As Directed At Side. , Cables Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forlaying Of Aluminium Conducter, Pvc Insulated Armoured, Served, Sheeted Cable 1100 Volts Grade At A Depth Of 750Mm Below Ground Level Over A Cushion Of 75Mm Thick Sand Alround And Protected With Burnt Bricks On Sides And Top On Surface, The Cable Run Shall Be Fixed On M.S. Clamps Etc. Of Suitable Size.As Per Direction Of Engineer-Incharge.Complete In All Respect The Armouring Of The Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc. ·300 Sqmm3.5 Core , · 240 Sqmm3.5 Core , · 150 Sqmm3.5 Core , · 95 Sqmm3.5 Core , · 70 Sqmm3.5 Core , · 50 Sqmm3.5 Core , · 25 Sqmm3.5 Core , · 16 Sqmm4 Core , · 10 Sqmm4 Core , · 16 Sqmm2 Core , · 10 Sqmm2 Core , · 6 Sqmm2 Core , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing Of Brass Nickle Plated Compression Gland For Pvc Insulated & Armoured Served Sheathed, Underground Cable Including Rubber Ring Etc. Complete In All Respects. The Armouring Of The Cable Shall Be Properly Connected With The Earth As Per Direction Of Engineer-Incharge. · 300 Sqmm3.5 Core , · 240 Sqmm3.5 Core , · 150 Sqmm3.5 Core , · 95 Sqmm3.5 Core , · 70 Sqmm3.5 Core , · 50 Sqmm3.5 Core , · 25 Sqmm3.5 Core , · 16 Sqmm4 Core , · 10 Sqmm4 Core , · 16 Sqmm2 Core , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forfixing Of Palm / Pin Type Copper Tin Plated Cables Sockets ( Lugs ) To The Cable Leads, Insuslating With Tape And Making Of Connections Etc. Complete In All Respects As Per Direction Of Engineer-Incharge. · 300 Sq.Mm , · 240 Sq.Mm , · 150 Sq.Mm , · 120 Sq.Mm , · 95 Sq.Mm , · 70 Sq.Mm , · 50 Sq.Mm , · 35 Sq.Mm , · 25 Sq.Mm , · 16 Sq.Mm , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forlaying Of 3 Core Standered Aluminium Conduktor Xlpe ( Cross Linked Polyethylene ) Insulated Pvc Bedded, Galvanised Flat Steel Strip Armoured Cables Confirming To I.S. 7098 ( Part-Ii With Latest Amendments ) 11 Kv Grade At A Depht Of 900 Mm Below Ground Level Over A Cushion Of 100 Mm Thick Fine River Sand All Around And Protected With Well Burnt Bricks In Sides And On The Top Put Across. Thearmouring Of Cable Shall Be Properly Connected With Earth Condutor By Clamps Etc. 3 X 120 Sq.Mm. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Formaking Indoor Cable End Jointing With Cast Resin Compound, Including Lugs And Other Jointing Materials, For Following Size Of 3 Core, Xlpe Aluminium Cable Of 11Kv Grade As Required. 120 Sq.Mm. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Formaking Outdoor Cable End Jointing With Cast Resin Compound, Including Lugs And Other Jointing Materials, For Following Size Of 3 Core, Xlpe Aluminium Cable Of 11Kv Grade As Required. 120 Sq.Mm. , Sub-Head-Iii ( Earthing & Loop Earthing ) Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forburying Of 600X 600X 6.0Mm G.I. Plate, Vestically For Earthing With Its Top At Least3 Meters Below Ground Level Complete With 20Mm Dia G.I. Pipe And Funnel For Watering And One Earthing Lead Of One No.8 To 10 Swg G.I. Wire In 15Mm Dia G.I. Pipe Upto ( Switch Board From Apron Switch Board The Cost Of G.I. Pipe And G.I. Pipe Will Be Extra ) 30Mm Square C.I. Frame With Linged Cover, , Masonary Housing, Alternate Layers Of Charcoal / Coke And Salt At Leat 150Mm Thick Alround Etc. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C For Burying Of 600Mm X 600Mm X 3 Mm Copper Plate Vertically For Earthing With Its Top At Least 3 Metres Below Ground Level Complete With 20Mm Dia G.I Pipe And Funnel For Watering And One Earthing Lead Ofone No. 8Swg Copper Wire In 15 Mm Dia G.I Pipe Up To Switch Board ( From Appron To Switch Board The Cost Of G.I Pipe And Copper Wire Will Be Extra ) 30 Cm Square C.I Frame With Hinged Cover Masonry Housingalternate Layers Of Charcoal / Coke And Salt Atleast 150Mm Thick Alround Etc. As Per Directions Of Engineer In Charge Complete In All Respects. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forburying Of 40Mm Dia X 4.5 Metres Long G.I. Pipe Vertically For Earthing Having 12Mm Dia. Holes Spaced 75Mm Apart Drilled Up To 2 Metre From The Bottom Complete With Earthing Lead Of No. 6 To 8 Swg Gi Wire In G.I. Pipe Up To Appron ( And From Appron To Switch Board The Cost Of G.I. Wire And Pipe Will Be Extra ) Upto Switch Board, 30Cm Square C.I. Box With Hinged Cover Masonary Enclosure, Funnel At Top, Alternate Layers Of Charcoal / Coke And Salt At Least 150Mm Thick Alround Etc. As Per Directions Of Engineer-In-Charge Complete In All Respects As Per Drawing. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C For Fixing One Number 8 Swg G.I. Wire In 15 Mm Dia. G.I. Pipe For Earthing, Laid In Ground Or In Wall Duly Concealed Including The Cost Of Cement, Sand Other Material Required For Proper Completion Of The Other Work As Directed At Site , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forlaying Of 32Mm X 6 Mm Copper Strip From Earth Electrode Directly In The Ground As Required Complete In All Respects. , Supply Of Material For Proper Completion Of The Work As Directed By Engineer I / C Forlaying Of 40Mm X 5 Mm G.I Strip From Earth Electrode Directly In The Ground As Required Complete In All Respects Including Testing Joint Of G.I Strip 40Mm X 5 Mm And 150Mm Long With G.I Bolts And Nuts Etc. Complete In All Respects , Main L.T. Panel Supply, Testing And Commissioning Of Electrical Panel, Modular Type, Front Accessible Only, Free Floor Standing Confirming To Minimum Ip:43 Degree Of Protection.The Panel Sheet Structure Shall Undergo Seven Tank Pre-Treatment Process Before Painting.The Sheet Steel Shall Be All Of 2.0Mm Thick Crca Sheet.All The Openable Compartments Of The Panel Shall Be Completely Shrouded And Provided With Padlocking Arrangement On All Compartments Including Bus Bar And Cable Alley Chambers.The Panel Height Shall Not Exceed 2200Mm And The Maximum Operating Height For Any Switchgear Shall Not Be More Than 1700Mm.The Panel Shall Be Provided With Minimum 75Mm Base Channel Frame Fabricated From Ismc Sections.All Bus Bar Links In The Panel Shall Be Solid Bus Bars With Coloured Pvc Shrinkable Sleeves, No Wires Will Be Acceptable.Continuous Earth Bus Shall Run Alround The Panel With Earthing Studs Provided At Minimum 2 Places.The Control Wiring Shall Be Carried Out With Minimum 1.5 / 2.5 Sqmm Copper Wires And Adequate Number Of No / Nc, Potential Free Contacts Incorporated For Remote Operation Of The Starters.Proper Sized Cable Termination Gland Plates Shall Be Provided Oncable Alleys And Knockouts For Same Shall Be Provided During Fabrication Stage Itself.The Panel Shall Be Provided With A Thermostatically Controlled Heating Arrangement ( 200 W ) To Take Care Of High Humidity Conditions.A 5A Socket Service Outlet ( Single Phase ) Shall Be Provided In One Of The Compartments As Ervice Outlet In The Panel.Panel Shall Be So Designed At To Have Minimum 20% Spare Feeders / Space.Panel Shall Undergo Epoxy Powder Coated Paint, Colour As Per Is:5 Requirement.All Cable Terminations Shall Be From Top.The Complete Panel Shall Be Fuse Less Type, For Control Circuits 2A / 6A Mcbs To Be Used. All Bus Bars Shall Be Of Aluminium, Electrolytic Grade Only.Maximum Design Density Shall Not Exceed 1 Amps / Sqmm.All Bus Bars Shall Be Insulated With Coloured Heat Shrinkable Pvc Sleeved.All Bus Bar Supports Shall Be Non Hygroscopic Dmc / Smc Supports. The Panel Shall Be Manufactured In Conformance To Requirements Of Local Electrical Inspector And It Shall Be Contractors Responsibility To Get Initial Approval Of Drawings And Also Final Approval Of Complete Electrical Works Related To This Section. The Minimum Clearances Between Bus Bars Shall Be As Follows : Phase To Phase - Minimum 20Mm Phase To Neutral-Minimum 15Mm Main L.T. Panel Incoming : One ( 1 ) No 630 Amp. 4P Mccb Of 25 Kabreaking Capacity Metering : One ( 1 ) No. ( 0-500V ) 96 X 96 Sqmm Voltmeter With Control Fuse & Selector Switch. One ( 1 ) No. ( 0-630A ) 96 X 96 Sqmm Ct Operated Ammeter With Selector Switch, Cts Etc. One ( 1 ) Set Of Phase Indication Lamp. Bus Bar : One ( 1 ) No. 630 Amp.Tpn Aluminimum Bus Bar Of Suitable Length. Outgoing : Phase Indication Lamps On Each Outgoing To Be Provided. 500 Amps Tp Mccb Of 25Ka ( Ics=Icu ) Breaking Capacity- 1 No 320 Amps Tp Mccb Of 25Ka ( Ics=Icu ) Breaking Capacity- 1 No 200 Amps Tp Mccb Of 25Ka ( Ics=Icu ) Breaking Capacity- 1 No 125 Amps Tp Mccb Of 25Ka ( Ics=Icu ) Breaking Capacity- 2 No 63 Amps Tp Mcb Of 10Ka ( Ics=Icu ) Breaking Capacity- 1 No 40 Amps Tp Mcb Of 10Ka ( Ics=Icu ) Breaking Capacity- 3 No 500 Amps Tp Mccb Of 25Ka ( Ics=Icu ) Breaking Capacity- 1 No Spare 200 Amps Tp Mccb Of 25Ka ( Ics=Icu ) Breaking Capacity- 1 No Spare 100 Amps Tp Mccb Of 25Ka ( Ics=Icu ) Breaking Capacity- 1 No Spare , Capacitor Panel Supply, Testing And Commissioning Apfc Panel Of 100 Kvar Capacity Suitable For Operation On 415 + 5% Volt, 3 Phase, 50Hz, Ac Supply, Having Mpp Type, Resin Bounded, Static12.5 Kvar Capacitors ( Without Oil ) In Tier Formationcomplete With Following 4P Mccbas Incomer Of The Panel, 8 Step Microprocessor Based Power Factor Controller Relay Capable To Select The Rating From 1 Kvar To Multiples Thereon Up To Max Rating Of The Panel, Current Limiting Contactors For Each Capacitors Protected With Mcbs, Ammeter ( Analogue Type ) With Cts, Voltmeter ( Analogue Type ) Selector Switches Indicating Lights, Cooling Fans For Panel, Earthing The Panel With 2 Nos. 25Mm X 5Mm Thick Gi Steel Flat From Existing Earth Bar, Connection Of Apfc Panel With Suitable Size 3.5 Core Aluminium Conductor Armoured Xlpe Cable From Main Lt Panel ( Maximum Length Of Cable 10 Mtrs. ) And Compression Glands Etc. As Reqd. The Panel Should Have Provision Of Timer Based Circuit In Apfc Relay To Switch On And Off The Static Part Automatically As And When Requried. Capacity Of Static Capacitors Should Be Accommodated From The Overall Rating Of The Panel And Should Be Designed To Switch In Independently. The Panel Should Be Manufactured With 1.6Mm Thick Crca Sheet Duly Powder Coated. Incoming 320 Amps., 36 Ka ( Ics = 100% Icu ) Breaking Capacity, 415 Volt, 4P Mccb With Continuously Adjustable Thermal Magnetic Release - 1 Nos. Out Going A ) 40 Amps., 10 Ka ( Ics = 100% Icu ) Breaking Capacity, 415 Volt, Tpn Mcb With Continuously Adjustable Thermal Magnetic Release - 8Nos. , Supply, Testing And Commissioning Of Electrical Panel, Modular Type, Front Accessible Only, Free Floor Standing Confirming To Minimum Ip:43 Degree Of Protection.The Panel Sheet Structure Shall Undergo Seven Tank Pre-Treatment Process Before Painting.The Sheet Steel Shall Be All Of 2.0Mm Thick Crca Sheet.All The Openable Compartments Of The Panel Shall Be Completely Shrouded And Provided With Padlocking Arrangement On All Compartments Including Bus Bar And Cable Alley Chambers.The Panel Height Shall Not Exceed 2200Mm And The Maximum Operating Height For Any Switchgear Shall Not Be More Than 1700Mm.The Panel Shall Be Provided With Minimum 75Mm Base Channel Frame Fabricated From Ismc Sections.All Bus Bar Links In The Panel Shall Be Solid Bus Bars With Coloured Pvc Shrinkable Sleeves, No Wires Will Be Acceptable.Continuous Earth Bus Shall Run Alround The Panel With Earthing Studs Provided At Minimum 2 Places.The Control Wiring Shall Be Carried Out With Minimum 1.5 / 2.5 Sqmm Copper Wires And Adequate Number Of No / Nc, Potential Free Contacts Incorporated For Remote Operation Of The Starters.Proper Sized Cable Termination Gland Plates Shall Be Provided Oncable Alleys And Knockouts For Same Shall Be Provided During Fabrication Stage Itself.The Panel Shall Be Provided With A Thermostatically Controlled Heating Arrangement ( 200 W ) To Take Care Of High Humidity Conditions.A 5A Socket Service Outlet ( Single Phase ) Shall Be Provided In One Of The Compartments As Ervice Outlet In The Panel.Panel Shall Be So Designed At To Have Minimum 20% Spare Feeders / Space.Panel Shall Undergo Epoxy Powder Coated Paint, Colour As Per Is:5 Requirement.All Cable Terminations Shall Be From Top.The Complete Panel Shall Be Fuse Less Type, For Control Circuits 2A / 6A Mcbs To Be Used. All Bus Bars Shall Be Of Aluminium, Electrolytic Grade Only.Maximum Design Density Shall Not Exceed 1 Amps / Sqmm.All Bus Bars Shall Be Insulated With Coloured Heat Shrinkable Pvc Sleeved.All Bus Bar Supports Shall Be Non Hygroscopic Dmc / Smc Supports. The Panel Shall Be Manufactured In Conformance To Requirements Of Local Electrical Inspector And It Shall Be Contractors Responsibility To Get Initial Approval Of Drawings And Also Final Approval Of Complete Electrical Works Related To This Section. The Minimum Clearances Between Bus Bars Shall Be As Follows : Phase To Phase - Minimum 20Mm Phase To Neutral-Minimum 15Mm Main L.T. Panel Incoming : One ( 1 ) No 200 Amp. 4P Mccb Of 25 Kabreaking Capacity Metering : One ( 1 ) No. ( 0-500V ) 96 X 96 Sqmm Voltmeter With Control Fuse & Selector Switch. One ( 1 ) No. ( 0-200A ) 96 X 96 Sqmm Ct Operated Ammeter With Selector Switch, Cts Etc. One ( 1 ) Set Of Phase Indication Lamp. Bus Bar : One ( 1 ) No. 200 Amp.Tpn Aluminimum Bus Bar Of Suitable Length. Outgoing : Phase Indication Lamps On Each Outgoing To Be Provided. 63 Amps Tp Mcb Of 10Ka ( Ics=Icu ) Breaking Capacity- 1 No 40 Amps Tp Mcb Of 10Ka ( Ics=Icu ) Breaking Capacity- 3 No 63 Amps Tp Mcb Of 10Ka ( Ics=Icu ) Breaking Capacity- 1 No Spare 40 Amps Tp Mcb Of 10Ka ( Ics=Icu ) Breaking Capacity- 1 No Spare , Substation Equipments H.T. Panel ( 11Kv ) ( Located In Meter Room ) Design, Manufacturing, Testing At Works, Supplyof Ht Panelas Per Specification And Comprising Of The Following :- Incomer / Outgoing Panel 630 A Vacuum Circuit Breaker Of ( 350 Mva ) 18.4 Ka Ruputuring Capacity At 11 Kv Rated, Totally Enclosed, Air Insulated Metal Clad Housing, Floor Mounting, Vertical Isolation, Vermin Proof, Fully Interlocked Horizontal Drawout Type Having Double Isolation. Manually And Motor Operated, Spring Charged ( Release Closing Mechanism ) Trip Free Type, Triple Pole Truck Mounted Draw Out, Vacuum Circuit Breaker, Incorporating Mechanical As Well As Electrical On / Off Indication.Spring Charge / Discharge Mechanical Indicator. 630 Amp Air Insulated But Encapsulated, Pvc Insulated Copper Bus Bars. C.T. Chamber With C.T.S 10 / 5. 15 Va Burden For Protection ( Class 5P 10 ) . Following Protection Shall Be Provided: 1 Nos Idmt Relay With Instantaneous 2 Nos. Over Currrent ( 50, 50 N ) Element And 1 No.Instantaneous Earth Fault Element ( 50-50N ) . ( O / C Setting 50%-200% And E / F Setting 20%-80% ) All Wiring Necessary For The Above Including Inter-Connections.The Size Of The Conductor Should Not Be Less Than 2.5 Sq. Mm. Copper Wire Where Required. Test Terminal Block, Fuses / 2A Spmcb , Circuit Labels, Set Of Phase, Indication Lamps Etc. As Per Standardpractise As Under. Red - Breaker Close ( On ) Green - Breaker Open ( Off ) Amber - Auto Trip Clear - Trip Circuit Healthy White - 3 Nos. One Per Phase Blue Spring Charged Control :- T-N-C ( Trip, Neutral. Close ) Breaker Control Switch With Indication Arrangement. Terminal Boxes With Single Gland Trifucating Cable Box Suitable For 11 Kv Aluminium Xlpe ( E ) Cable Of Size 3C X 95 Sq. Mm. For Incoming / Outgoingbreaker. Ht Danger Plate. ( As Per Is Specification ) 2 Runs Of 65 X 8 Mm Earth Bus Shall Be Provided For The Full Length Of The Panel. Power Pack, Battery Power Pack Shall Be Rated For Minimum Five ( 5 ) Trippings.For Dc Power One No. Source Selector Switch To Be Incorporated I.E. One Source From Power Pack And Other From Outside. Necessary D.C. Supply Healthy Indication Lamp ( White Colour ) , Switch With Alarm. Surge Supressor As Required. Dc Voltmeter, 0-30 Volt, Digital Type. Ht Panel Switchboard Complete With All Interconnections, Labels, Wiring Etc, Complete As Described Above In Item Nos.A And B And Asper Specifications. , Main L.T. Panel Supply, Testing And Commissioning Of Electrical Panel, Modular Type, Front Accessible Only, Free Floor Standing Confirming To Minimum Ip:43 Degree Of Protection.The Panel Sheet Structure Shall Undergo Seven Tank Pre-Treatment Process Before Painting.The Sheet Steel Shall Be All Of 2.0Mm Thick Crca Sheet.All The Openable Compartments Of The Panel Shall Be Completely Shrouded And Provided With Padlocking Arrangement On All Compartments Including Bus Bar And Cable Alley Chambers.The Panel Height Shall Not Exceed 2200Mm And The Maximum Operating Height For Any Switchgear Shall Not Be More Than 1700Mm.The Panel Shall Be Provided With Minimum 75Mm Base Channel Frame Fabricated From Ismc Sections.All Bus Bar Links In The Panel Shall Be Solid Bus Bars With Coloured Pvc Shrinkable Sleeves, No Wires Will Be Acceptable.Continuous Earth Bus Shall Run Alround The Panel With Earthing Studs Provided At Minimum 2 Places.The Control Wiring Shall Be Carried Out With Minimum 1.5 / 2.5 Sqmm Copper Wires And Adequate Number Of No / Nc, Potential Free Contacts Incorporated For Remote Operation Of The Starters.Proper Sized Cable Termination Gland Plates Shall Be Provided Oncable Alleys And Knockouts For Same Shall Be Provided During Fabrication Stage Itself.The Panel Shall Be Provided With A Thermostatically Controlled Heating Arrangement ( 200 W ) To Take Care Of High Humidity Conditions.A 5A Socket Service Outlet ( Single Phase ) Shall Be Provided In One Of The Compartments As Ervice Outlet In The Panel.Panel Shall Be So Designed At To Have Minimum 20% Spare Feeders / Space.Panel Shall Undergo Epoxy Powder Coated Paint, Colour As Per Is:5 Requirement.All Cable Terminations Shall Be From Top.The Complete Panel Shall Be Fuse Less Type, For Control Circuits 2A / 6A Mcbs To Be Used. All Bus Bars Shall Be Of Aluminium, Electrolytic Grade Only.Maximum Design Density Shall Not Exceed 1 Amps / Sqmm.All Bus Bars Shall Be Insulated With Coloured Heat Shrinkable Pvc Sleeved.All Bus Bar Supports Shall Be Non Hygroscopic Dmc / Smc Supports. The Panel Shall Be Manufactured In Conformance To Requirements Of Local Electrical Inspector And It Shall Be Contractors Responsibility To Get Initial Approval Of Drawings And Also Final Approval Of Complete Electrical Works Related To This Section. The Minimum Clearances Between Bus Bars Shall Be As Follows : Phase To Phase - Minimum 20Mm Phase To Neutral-Minimum 15Mm Main L.T. Panel Incoming : One ( 1 ) No800 Amp. 4 Pole Acb Of 50 Kabreaking Capacity Mdo Type Metering : One ( 1 ) No. ( 0-500V ) 96 X 96 Sqmm Voltmeter With Control Fuse & Selector Switch. One ( 1 ) No. ( 0-800A ) 96 X 96 Sqmm Ct Operated Ammeter With Selector Switch, Cts Etc. One ( 1 ) Set Of Phase Indication Lamp. Bus Bar : One ( 1 ) No. 800 Amp.Tpn Aluminimum Bus Bar Of Suitable Length. Outgoing : Phase Indication Lamps On Each Outgoing To Be Provided. 630 Amps Tp Mccb Of 25Ka ( Ics=Icu ) Breaking Capacity- 1 No 320 Amps Tp Mccb Of 25Ka ( Ics=Icu ) Breaking Capacity- 1 No 32 Amps Sp Mcb Of 10Ka ( Ics=Icu ) Breaking Capacity- 2 No 6 Amps Sp Mcb Of 10Ka ( Ics=Icu ) Breaking Capacity- 1 No 630 Amps Tp Mccb Of 25Ka ( Ics=Icu ) Breaking Capacity- 1 No Spare 320 Amps Tp Mccb Of 25Ka ( Ics=Icu ) Breaking Capacity- 1 No Spare 63 Amps Tp Mcb Of 10Ka ( Ics=Icu ) Breaking Capacity- 1 No Spare , Feeder Piller-1 Supplying Assembling Erecting Connecting, Testing And Commissioning Of Sizes Of 3.15Mm Thick Sheet Metal Enclosed Outdoor Type Feeder Pillars With Water Proof Dust And Vermin Proof Hinged And Lockable Doors Including Rain Protection Cover Complete With Interconnections, With Aluminium Wire, Tapes, Bonding To Earth And Painting Complete As Required.The Feeder Pillar Shall Consist Ofmccb As Incoming And Mccb / Mcb As Outgoing. ( Note : This Panel Shall Be A Front Operated, With Cable Entry From The Top / Bottom.The Fault With Standing Capacity Shall Be 10 Ka.Earth Busbar Shall Be Part Of The L.T. Panel ) . Incoming 1No. Of 320 Amps Tpn Mccb Of 25Ka Service Breaking Capacity And 320 Amp Trip Setting. Bus Bar 1 Set Of 320 Amps Tpn Aluminium Bus Bars Of Suitable Length And Of Cross Section . Bus Bar Shall Be Insulated By Heat Shrinkable Sleaves & Clip On Shrouds For Joints.Bus Bar Shall Be Designed To With Stand A Fault Level Of 25 Ka At 415 Volts. 3Nos. Phase Indicating Lamp Each Lamp Shall Have One Toggle Switch . Outcoming 200Amp Tpmccb ( 25Ka ) - 1 Nos. 63Amp Tpmcb ( 10Ka ) - 1 Nos. 40Amp Tpmcb ( 10Ka ) - 2 Nos. 63Amp Spmcb ( 10Ka ) - 1 Nos. 32Amp Spmcb ( 10Ka ) - 2 Nos , Telephone System Supply Ofmodular Boxes, Base & Cover Plate :- Supplying Following Size / Modules, Gi Box Along With Modular Base& Cover Plate For Modular Switches In Recess Etc As Required. • 1 Or 2 Module ( 75Mm X 75 Mm ) , Supply Ofmodular Type Switch / Socket :- Supplying Following Modular Switch / Socket On Theexisting Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc As Required. • Telephone Socket Outlet , Tv Antenna Socket Outlet , Supplyingoftelephone Wire Following Pair 0.5 Sqmm Fr Pvc Insulated Annealed Copper Conductor, Unarmoured Telephone Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 2 Pair , Supplyingof10 Pair Junction Boxes For Floors And Building With Krone Connectors , With Connection And Punching Of Same , Supplyingof Co-Axial Tv Cable Rg-6 Graded, 0.7 Mm Solid Copper Conductor Pe Insulated, Shielded With Fine Tinned Copper Braid And Protected With Pvc Sheath In The Existing Surface / Recessed Steel / Pvc Conduit As Required. , Miscelleneous Supply Of Ceiling Fan With Fan Motor Of A.C Permanent Insulation, Capacitor Rating Conforming Bee 5 Star Rating And Is:374 / 79 And Also Comply With Is: 1709 / 1984 With Latest Amendment. The Rated Voltage 220 / 240 Volts, 50Hz, 1-Ph Ac The Fan Assemble Should Consists Of Down Road Blades, Shackle Canopies Etc And With Double Ball Bearing System. Bee 5 Star Rated-1200Mm Sweep , Supplyingof Following Size Of Preforated Pre-Painted M.S. Cable Tray With Perforration Not More Than 17.5% In Convenient Sections, Jointed With Connector, Suspended From The Ceiling With M.S. Suspender Including Bolts & Nuts, Painting Suspenders Etc. As Required 100Mm Width X 50 Mm Depth X 1.6Mm Thickness. , 150Mm Width X 50 Mm Depth X 1.6Mm Thickness. , Supplyingof Unplastisized Rigid Pvc Pipe Conforming To Is:13592 Type A Including Jointing , Cuttingand Making Good The Walls & Floors As Per Requirement. 150Mm , Supplyingof Ac 230 / 250 Volts, 50 Hz Exhaust Fans Including Providing Nuts, Bolts, Mounting Frame And Other Accessories Including Connections Etc. Complete As Required 300Mm Sweep. , Supply Of Ac 600Mm Sweep, 230 / 250 Volts, 50 Hz Air Circulator Connection Etc. Complete As Required , Supplyingof Three Phase Electronic Energy Meter , Supplyingof Following Dia Rcc Pipe Np 2 Class ( Light Duty ) In Ground Complete With Rcc Collars, Jointing With Cement Mortar 1:2 ( 1 Cement : 2 Fine Sand ) Including Trenching ( 75 Cm ) Deep And Refilling Etc. As Required. 100Mm Dia , 150Mm Dia , Supplyingof Material For Following Size Of Cable Chamber Made Of 230 Mm Thick Brick Work In Cement Mortar ( 1 Cement : 6 Sand ) With Pcc 100 Mm Thick Pcc Base Plastering Of Inner And Outer Surface With Cement Mortar Including Providing Of Heavy Duty C.I Cover Complete With Digging, Refilling And Removal Of Surplus Soil Complete As Required. 600 Mm X 600 Mmx 800 Mm Deep , 900 Mm X 900 Mmx 1000 Mm Deep , External Lighting Supplying Steel Tubular Pole 9 Meter Long Designated 410 Sp-27 In 1:3:6 Cement Concrete Foundation Including Excavation Back Filling Etc. Complete In All Respects , Painting Of The Electric Pole With 2 Coats Of Aluminium Paint Over Red Oxide Primer Complete In All Respects. , Supplyof Led Street Light Fitting Having Die Cast Aluminium Body And Diffuser With Driver Set Suitable For 52 Watt To 72 Watt. Confirming To Ip66 Protection Complete In All Respect.Cat-Aaa , Supply Of Bakelite Sheet 3 Mm Thick Of Suitable Size & Connector , Supply Of 6 Amp To 32 Amp Dp Mcb ( 10Ka ) ( Legrand Lexic ) For Poles , Supplyfollowing Capacity Of Automatic Street Light Cubicle Control Panel Painted With Anti Corrosive Alkali And Acid Proof Paint Consisting Of Time Switch Tso 100 Series With Contractors, Hrc Fuses, Isolating Switch Metering Instrument & Instrument Box With Cts Etc. In Case Of Tpn Complete In All Respect. 40 Amp Spn , Supplying Of Gate Light Fixture Fabricated Out Of M.S. Pipe 4.05Mm Thick 75Mm Dia 0.5M Long In Cement Concrete Foundations 1:3:6 Complete With 1 No. Crompton Spt 1107 Il / Bm Or Equivalent With 70W Sodium Vapour Lamp Complete With All Accessories In Outdoor Type Control Gear Box Necessary Civil Work Marshelling Box Having Two No. Three Way Brass Connector, One No. 15 Amps Kit Kat Fuses, Cable Glands, Earthing Stud, Necessary Interconnections And 40Mm Dia Gi Pipe B Class For Protection Of The Upright Cable And Painting Etc. As Required. Make: Philips Cat No. Hpc 104 Spc 104 1Xson 70 W E , Safety Equipments Supplying Of Fire Buckets, Round Bottom Made Of G.I. Sheet 9-11 Litres Capacity Duly Painted As Per Fire Brigade Design, Supported On Hanging Bracket Chained And Locked, Initially Filled With Fine River Sand, Water As Per Directions Of Engineer-In-Charge. , Supplyingof 1800 Mm X 900 Mm X 12 Mm Thick Chequered Rubber Matting Of Tested Quality , Supplyingof Danger Board Fabricated From 10 Gauge Ms Sheet As Per Ie Rules , Supplyingof Shock Treatment Chart ( Prescribed Under I.E.Rules ) Duly Framed With Glass And Supported From Back With Hard Board Or Soft Board For Proper Completion Of Work. , Supplyingof Fire Extinguishers, Abc Type 4.00 Kg. Capacity ( Isi Marked Is : 15683 & Tac Approved ) Complete With Initial Charges And Wall Bracket, Along With Supply Of All Materials For Proper Completion Of Work. , Supplyingof Co2 Typefire Extinguishers, 4.50 Kg. Capacity ( Isi Marked Is : 2878 & Tac Approved ) Complete With Initial Charges And Wall Bracket, Along With Supply Of All Materials For Proper Completion Of Work. , Supplying, Testing And Commissioning Of Amf Start 320Kva Dg Set Totally Enclosed In An Sound Proof Acoustic Enclosure ( As Per Cpcb Norms ) Comprisiing Of Diesel Engine Of Suitable Bhp Directly Coupled With Alternator Capable To Deliver 320Kva, 415 Volt, 50Hz, 3 Phase, Ac Supply At 0.8 Power Factor Mounted On A Common Base Frame Complete In All Respect With Generator Control Panel With Metering Equipments, All Required Safety Devices, Fittings, Batteries, Battery Leads And Other Accessories, Diesel Oil Fuel Tank Of 250 Ltrs. Capacity, Fuel Piping Valves, Filters, Supports, Control And Power Cables From Dg Set To Amf Panel Having Residential Type Sliencer, Exhaust Piping With Asbestos Roping, Antivibration Mounting Pads First Filling Of Lub Oil, Complete As Per Specifications And Conditions Earth Connections Etc. As Reqd. Incl.Packing, Insurance, Transporation, Loading And Unloading Charges Testing On Load I / C Load Arrangement Charges With T&P, High Speed Diesel Oil And Initial Lubricating Oil Filling Make : Jackson , Supplying, Testing And Commissioning Of315 Kva Transformer Incl. Transportation Charges Upto Site.

Key Value

Document Fees
INR 1180 /-
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work: Construction of 1000 Capacity Auditorium between Mathura & Vrindavan Distt. Mathura (U.P.) [MATERIAL SUPPLY JAN-2023]
Sl. No. Item Description
1Supply of material for proper completion of the work as directed by Engineer I/C forWiring points for light with 1 sqmm.FR PVC insulated multistrand single core copper condutor cable in PVC conduit pipe partly concealed in wall and partly laid in slab along with the reinforcement before concreting, complete with 1.5 sqmm.FR PVC insulated multistrand copper conductor cable as earth continuity wire and piano type switch etc. complete in all respects.
2Supply of material for proper completion of the work as directed by Engineer I/C forSame as item No.(1) but for two way light Points.
3Supply of material for proper completion of the work as directed by Engineer I/C forSame as item No.(1) but for fanandlight duty exhaust fan.
4Supply of material for proper completion of the work as directed by Engineer I/C forSame as item No.(1) but for5 Amp plug point
5Supply of material for proper completion of the work as directed by Engineer I/C forSame as item No.(1) but forcall bell point
6Supply of material for proper completion of the work as directed by Engineer I/C forAddition when modular type switches etc are used in place of piono type switches etc. in various wiring points.
7Supply of material for proper completion of the work as directed by Engineer I/C forAddition for light / fan points with modular type switchin place of piono type switch.
8Supply of material for proper completion of the work as directed by Engineer I/C forAddition for 2 way light pointswith modular type switchin place of piono type switch.
9Supply of material for proper completion of the work as directed by Engineer I/C forAddition for plugpointswith modular type switchin place of piono type switch.
10Supply of material for proper completion of the work as directed by Engineer I/C forwiring of submain 2 number 4 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 2.5 sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.
11Supply of material for proper completion of the work as directed by Engineer I/C forwiring of submain 2 number 6 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 20mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 4 sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.
12Supply of material for proper completion of the work as directed by Engineer I/C forwiring of submain 2 number 10 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 25mm dia PVC conduit partly concealed in wall and partly laid in slab along with one number 6 sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.
13Supply of material for proper completion of the work as directed by Engineer I/C forwiring of submain 4 number 10 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 32mm dia PVC conduitalong with two numbers 6 sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.
14Supply of material for proper completion of the work as directed by Engineer I/C forwiring of submain 4 number 16 sqmm . FR PVC insulated 1100 V grade multistranded single core copper conductor cable in heavy duty 40mm dia PVC conduitalong with two numbers 10 sqmm FR PVC insulated multistranded copper conductor cable as earth contunity wire etc. complete in all respects.
15Supply of material for proper completion of the work as directed by Engineer I/C forfixingand concealing of20mm dia.2mm thick PVC conduit pipe with ISI mark embossed and with PVC acessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/ adhesive to make the complete piping rigid,plastering with cement sand mortar finished to level with matching colour including cost of material etc required for proper completion of work .( for Telephonepoints)
16Supply of material for proper completion of the work as directed by Engineer I/C forwiring of submains with 2 nos. 2.5 sq.mm & with 1 no. earth wire of 1.5 sq.mm FR PVC insulated 1100 V grade single core multistrand copper conductor cable in existing PVC conduit complete.
17Supply of material for proper completion of the work as directed by Engineer I/C forErection and testing of ceiling fan and regulator for room height upto 3.5mts. including3mm thick G.I. down rod 19mm dia duly painted, complete in all respects.
18Supply of material for proper completion of the work as directed by Engineer I/C forErection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects.
19Supply of material for proper completion of the work as directed by Engineer I/C forFixing of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting.
20Supply of material for proper completion of the work as directed by Engineer I/C forfixingofelectronic fan regulator(modular) 120-280 V. ISImarked, on the existing switch board including making connetion, required material,etc for proper completion of work to the satisfaction of Engineer in charge of work.
21Supply of material for proper completion of the work as directed by Engineer I/C forfixing of recess mounting round 15 to 18 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect.CAT- AAA
22Supply of material for proper completion of the work as directed by Engineer I/C forfixing of single light wall bracket on matching M.D.F.E.G. Board base etc. complete in all respect.Cat AAA.
23Supply of material for proper completion of the work as directed by Engineer I/C forfixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. CAT- AAA
24Supply of material for proper completion of the work as directed by Engineer I/C forfixing of LED Tube Light with batten suitable for up to 2 X 22 watt LED tube light fitting including tube on Surface complete in all respect. CAT- AAA
25Supply of material for proper completion of the work as directed by Engineer I/C forfixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect.CAT-AAA
26Supply of material for proper completion of the work as directed by Engineer I/C forfixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT- AAA
27Supply of material for proper completion of the work as directed by Engineer I/C forfixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 140 to 150 Watt. Confirming to IP 66 protection complete in all respect.CAT-AAA
28Supply of material for proper completion of the work as directed by Engineer I/C forSuuply and fixing of 17 watt LED Mirror Light and complete in all respect.
29Supply of material for proper completion of the work as directed by Engineer I/C forerection of Recess mounted maintained type EXIT LED light with in built battery pack for three hours duration, complete in all respects
30Supply of material for proper completion of the work as directed by Engineer I/C forfixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 40 to 50 Watt. Confirming to IP 65 protection complete in all respect.CAT-AAA
31Supply of material for proper completion of the work as directed by Engineer I/C forfixing of Call Bell Of Approved Make on matching polished MDFEG/TEAK PLY board including making connectionetc. as required.
32Supply of material for proper completion of the work as directed by Engineer I/C forfixing of water tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection . complete in all respect. CAT-AAA
33Supply of material for proper completion of the work as directed by Engineer I/C forfixing of flush/surface mounting distribution boardswithout MCB with additional metal doorcomplete in all respects.(CAT: A) 12 Way SPN
344 Way TPN
356 Way TPN
368 Way SPN
37Supply of material for proper completion of the work as directed by Engineer I/C forfixing and making connection of following FPMCBS complete in all respects as per direction and satisfaction of engineer-in-charge. 25 Amp. DP MCB
38Supply of material for proper completion of the work as directed by Engineer I/C forfixing of flush/surface mounting distribution boardswithout MCB with additional metal doorcomplete in all respects.(CAT: B) 6 Way TPN
394 Way TPN
408 Way SPN
41Supply of material for proper completion of the work as directed by Engineer I/C forfixing of 240 volts "L" series miniature circuit breaker 6 Amp. To 32 Amp. (10 K A ) in existing MCB, DB complete with connections as required. (CAT: A) 6 - 32 amps.
42Supply of material for proper completion of the work as directed by Engineer I/C forfixing and making connection of following MCBS complete in all respects as per direction and satisfaction of engineer-in-charge.(CAT: A) 40 Amp. 4P MCB(10 KA)
4363 Amp. DP MCB
44Supply of 63 Amp 4P MCB (10KA) C Curve.
45Supply of material for proper completion of the work as directed by Engineer I/C forfixing of 40 Amp. 4 pole mcb(10KA). (CAT: B)
46Supply of material for proper completion of the work as directed by Engineer I/C forfixing of power plug with 20A/250 V flush type modular switch and 5 Pin 20 A/250 Volt flush type universal modular socket switch on concealedM.S. box.
47Supply of material for proper completion of the work as directed by Engineer I/C forfixing of power plug with 15A/250 V flush type switch and 5 Pin 15 A/250V flush type universal socket in suitable M.S. box of 175mmx100x50mm size with phenolic laminated bakellite sheet cover 3mm thick fixed with brass machine screws and cup washer.
48Supply of material for proper completion of the work as directed by Engineer I/C forfixingof Sheet Steel Enclosure Surface/ Flush Mounting fitted With 20/32 Amp. 2Pin and earth metal clad scraping earth plug and socket complete in allrespects as per direction and satisfaction of engineer-in-charge.
49Supply of material for proper completion of the work as directed by Engineer I/C forfixing Single Pole MCBS Blanking Plate complete in all respects. (CAT -B)
50MAIN DISTRIBUTION BOARD Supplying of material for surface/flush mounting 4 ways V TPN distribution board with additional door cithout MCB complete in all respect, as directed at site by Engineer in charge.
51Supplying of material for125 Amp 4P MCCB (25KA) Thermal Magnetic release.
52Supplying of material for40 Amp TP MCB (10KA) C Curve.
53Supplying of material forof 63 Amp TP MCB (10KA) C Curve.
54MCB Supply of material for proper completion of the work as directed by Engineer I/C forfixing of 6 Amp. DP MCB (10KA) C Curve. (CAT: B)
55Supply ofMODULAR BOXES, BASE & COVER PLATE :- Supply of material for proper completion of the work as directed by Engineer I/C forfixingfollowing size/modules, GI box along with modular base& cover plate for modular switches in recess etc as required. 1 or 2 Module (75mm X 75 mm)
56Supply of MODULAR TYPE SWITCH / SOCKET :- Supply of material for proper completion of the work as directed by Engineer I/C forfixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required. Telephone socket outlet
57Supply of material for proper completion of the work as directed by Engineer I/C fordrawing telephone wire following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 2 Pair
58EARTHING SYSTEM Supply of material for proper completion of the work as directed by Engineer I/C forburying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of two No.8to10SWG G.I.wire in 15mm diaG.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects.
59Supply of material for proper completion of the work as directed by Engineer I/C forlaying of 25mm x 3mm G.I. strip from earth electrode directly in the ground.
60Supply of material for proper completion of the work as directed by Engineer I/C forfixing of two number 8 SWG G.I. wire in 15mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, other material required for proper completion of work as directed at side.
61CABLES Supply of material for proper completion of the work as directed by Engineer I/C forlaying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1100 Volts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size.as per direction of Engineer-Incharge.complete in all respect The armouring of the cable shall be properly connected with the earth conductor by clamps etc. ·300 sqmm3.5 core
62·         240 sqmm3.5 core
63·         150 sqmm3.5 core
64·         95 sqmm3.5 core
65·         70 sqmm3.5 core
66·         50 sqmm3.5 core
67·         25 sqmm3.5 core
68·         16 sqmm4 core
69·         10 sqmm4 core
70·         16 sqmm2 core
71·         10 sqmm2 core
72·         6 sqmm2 core
73Supply of material for proper completion of the work as directed by Engineer I/C forfixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. ·    300 sqmm3.5 core
74·         240 sqmm3.5 core
75·         150 sqmm3.5 core
76·         95 sqmm3.5 core
77·         70 sqmm3.5 core
78·         50 sqmm3.5 core
79·         25 sqmm3.5 core
80·         16 sqmm4 core
81·         10 sqmm4 core
82·         16 sqmm2 core
83Supply of material for proper completion of the work as directed by Engineer I/C forfixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. ·      300 Sq.mm
84·         240 Sq.mm
85·         150 Sq.mm
86·         120 Sq.mm
87·         95 Sq.mm
88·         70 Sq.mm
89·         50 Sq.mm
90·         35 Sq.mm
91·         25 Sq.mm
92·         16 Sq.mm
93Supply of material for proper completion of the work as directed by Engineer I/C forlaying of 3 core standered aluminium conduktor XLPE (Cross linked polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cables confirming to I.S. 7098(Part-II with latest amendments) 11 KV grade at a depht of 900 mm below ground level over a cushion of 100 mm thick fine river sand all around and protected with well burnt bricks in sides and on the top put across. Thearmouring of cable shall be properly connected with earth condutor by clamps etc. 3 x 120 sq.mm.
94Supply of material for proper completion of the work as directed by Engineer I/C formaking indoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium cable of 11KV grade as required. 120 sq.mm.
95Supply of material for proper completion of the work as directed by Engineer I/C formaking outdoor cable end jointing with cast resin compound, including lugs and other jointing materials, for following size of 3 core, XLPE aluminium cable of 11KV grade as required. 120 sq.mm.
96SUB-HEAD-III (EARTHING & LOOP EARTHING) Supply of material for proper completion of the work as directed by Engineer I/C forburying of 600x 600x 6.0mm G.I. plate, vestically for earthing with its top at least3 meters below ground level complete with 20mm dia G.I. Pipe and funnel for watering and one earthing lead of one no.8 to 10 SWG G.I. wire in 15mm dia G.I. pipe upto (Switch board from apron Switch board the cost of G.I. pipe and G.I. pipe will be extra) 30mm square C.I. frame with linged cover, ,masonary housing, alternate layers of charcoal/coke and salt at leat 150mm thick alround etc.
97Supply of material for proper completion of the work as directed by Engineer I/C for burying of 600mm X 600mm X 3 mm copper Plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I pipe and funnel for watering and one earthing lead ofone no. 8SWG copper wire in 15 mm dia G.I pipe up to switch board ( from appron to switch board the cost of G.I pipe and copper wire will be extra) 30 cm square C.I frame with hinged cover masonry housingalternate layers of charcoal / coke and salt atleast 150mm thick alround etc. as per directions of Engineer in charge complete in all respects.
98Supply of material for proper completion of the work as directed by Engineer I/C forburying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8 SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing.
99Supply of material for proper completion of the work as directed by Engineer I/C for fixing one number 8 SWG G.I. wire in 15 mm dia. G.I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand other material required for proper completion of the other work as directed at site
100Supply of material for proper completion of the work as directed by Engineer I/C forLaying of 32mm X 6 mm Copper strip from earth electrode directly in the ground as required complete in all respects.
101Supply of material for proper completion of the work as directed by Engineer I/C forLaying of 40mm X 5 mm G.I strip from earth electrode directly in the ground as required complete in all respects including testing joint of G.I strip 40mm x 5 mm and 150mm long with G.I bolts and nuts etc. complete in all respects
102MAIN L.T. PANEL Supply, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.0mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCB"s to be used. All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports. The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mm Main L.T. Panel Incoming : One (1) No 630 Amp. 4P MCCB of 25 KABreaking capacity Metering : One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. One (1) No. (0-630A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. One (1) Set of Phase Indication Lamp. Bus Bar : One (1) No. 630 Amp.TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on each outgoing to be provided. 500 Amps TP MCCB of 25KA (Ics=Icu) Breaking Capacity- 1 No 320 Amps TP MCCB of 25KA (Ics=Icu) Breaking Capacity- 1 No 200 Amps TP MCCB of 25KA (Ics=Icu) Breaking Capacity- 1 No 125 Amps TP MCCB of 25KA (Ics=Icu) Breaking Capacity- 2 No 63 Amps TP MCB of 10KA (Ics=Icu) Breaking Capacity- 1 No 40 Amps TP MCB of 10KA (Ics=Icu) Breaking Capacity- 3 No 500 Amps TP MCCB of 25KA (Ics=Icu) Breaking Capacity- 1 No Spare 200 Amps TP MCCB of 25KA (Ics=Icu) Breaking Capacity- 1 No Spare 100 Amps TP MCCB of 25KA (Ics=Icu) Breaking Capacity- 1 No Spare
103CAPACITOR PANEL Supply, testing and commissioning APFC Panel of 100 KVAR capacity suitable for operation on 415 + 5% Volt, 3 Phase, 50Hz, AC supply, having MPP type, resin bounded, static12.5 KVAR capacitors (without oil) in tier formationcomplete with following 4P MCCBas incomer of the panel, 8 step microprocessor based power factor controller relay capable to select the rating from 1 KVAR to multiples thereon up to max rating of the panel, current limiting contactors for each capacitors protected with MCBs, Ammeter (Analogue type) with CTs, Voltmeter (Analogue type) selector switches indicating lights, cooling fans for panel, earthing the panel with 2 Nos. 25mm x 5mm thick GI steel flat from existing earth bar, connection of APFC panel with suitable size 3.5 core aluminium conductor armoured XLPE cable from main LT panel (maximum length of cable 10 mtrs.) and compression glands etc. as reqd. The panel should have provision of timer based circuit in APFC relay to switch ON and OFF the static part automatically as and when requried. Capacity of Static capacitors should be accommodated from the overall rating of the panel and should be designed to switch in independently. The panel should be manufactured with 1.6mm thick CRCA sheet duly powder coated. Incoming 320 Amps., 36 KA (ICS = 100% ICU) breaking capacity, 415 Volt, 4P MCCB with continuously adjustable thermal magnetic release - 1 Nos. OUT GOING a) 40 Amps., 10 KA (ICS = 100% ICU) breaking capacity, 415 Volt, TPN MCB with continuously adjustable thermal magnetic release - 8Nos.
104Supply, testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.0mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCB"s to be used. All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports. The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mm Main L.T. Panel Incoming : One (1) No 200 Amp. 4P MCCB of 25 KABreaking capacity Metering : One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. One (1) No. (0-200A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. One (1) Set of Phase Indication Lamp. Bus Bar : One (1) No. 200 Amp.TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on each outgoing to be provided. 63 Amps TP MCB of 10KA (Ics=Icu) Breaking Capacity- 1 No 40 Amps TP MCB of 10KA (Ics=Icu) Breaking Capacity- 3 No 63 Amps TP MCB of 10KA (Ics=Icu) Breaking Capacity- 1 No Spare 40 Amps TP MCB of 10KA (Ics=Icu) Breaking Capacity- 1 No Spare
105SUBSTATION EQUIPMENTS H.T. PANEL (11KV) ( LOCATED IN METER ROOM) Design, manufacturing, testing at works, supplyof HT Panelas per specification and comprising of the following :- INCOMER/OUTGOING PANEL 630 A Vacuum circuit breaker of (350 MVA) 18.4 KA ruputuring capacity at 11 KV rated, totally enclosed,air insulated metal clad housing, floor mounting, vertical isolation,vermin proof,fully interlocked horizontal drawout type having double isolation. Manually and motor operated, spring charged( release closing mechanism) trip free type,triple pole truck mounted draw out, vacuum circuit breaker, incorporating mechanical as well as electrical ON/OFF indication.Spring charge/discharge mechanical indicator. 630 amp air insulated but encapsulated,PVC insulated Copper bus bars. C.T. chamber with C.T."s 10/5. 15 VA burden for protection (class 5P 10). Following protection shall be provided: 1 Nos IDMT relay with instantaneous 2 nos. over currrent (50, 50 N) element and 1 no.instantaneous earth fault element(50-50N).(O/C setting 50%-200% and E/F setting 20%-80%) All wiring necessary for the above including inter-connections.The size of the conductor should not be less than 2.5 sq. mm. Copper wire where required. Test terminal block, fuses/2A SPMCB , circuit labels,set of phase, indication lamps etc. as per standardpractise as under. Red - Breaker close (ON) Green - Breaker open (OFF) Amber - auto trip Clear - trip circuit healthy white - 3 nos. one per phase Blue spring charged Control :- T-N-C(Trip, Neutral. Close) breaker control switch with indication arrangement. Terminal boxes with single gland trifucating cable box suitable for 11 KV Aluminium XLPE (E) cable of size 3C x 95 Sq. mm. for incoming/outgoingbreaker. HT Danger Plate.(as per IS specification) 2 Runs of 65 X 8 mm earth bus shall be provided for the full length of the panel. Power Pack, Battery power pack shall be rated for minimum five (5) trippings.For DC power one no. source selector switch to be incorporated i.e. one source from power pack and other from outside. Necessary D.C. supply healthy indication lamp (White Colour), switch with alarm. Surge supressor as required. DC Voltmeter, 0-30 Volt, Digital type. HT Panel switchboard complete with all interconnections, labels, wiring etc, complete as described above in item nos.A and B and asper specifications.
106MAIN L.T. PANEL Supply,testing and commissioning of electrical panel, modular type, front accessible only, free floor standing confirming to Minimum IP:43 degree of protection.The panel sheet structure shall undergo seven tank pre-treatment process before painting.The sheet steel shall be all of 2.0mm thick CRCA sheet.All the openable compartments of the panel shall be completely shrouded and provided with padlocking arrangement on all compartments including bus bar and cable alley chambers.The panel height shall not exceed 2200mm and the maximum operating height for any switchgear shall not be more than 1700mm.The panel shall be provided with minimum 75mm base channel frame fabricated from ISMC sections.All bus bar links in the panel shall be solid bus bars with coloured PVC shrinkable sleeves, no wires will be acceptable.Continuous earth bus shall run alround the panel with earthing studs provided at minimum 2 places.The control wiring shall be carried out with minimum 1.5/2.5 sqmm copper wires and adequate number of NO/NC, potential free contacts incorporated for remote operation of the starters.Proper sized cable termination gland plates shall be provided oncable alleys and knockouts for same shall be provided during fabrication stage itself.The panel shall be provided with a thermostatically controlled heating arrangement (200 W) to take care of high humidity conditions.A 5A socket service outlet (single phase) shall be provided in one of the compartments as ervice outlet in the panel.Panel shall be so designed at to have minimum 20% spare feeders/space.Panel shall undergo epoxy powder coated paint, colour as per IS:5 requirement.All cable terminations shall be from top.The complete panel shall be fuse less type, for control circuits 2A/6A MCB"s to be used. All bus bars shall be of aluminium, electrolytic grade only.Maximum design density shall not exceed 1 Amps/Sqmm.All bus bars shall be insulated with coloured heat shrinkable PVC sleeved.All bus bar supports shall be non hygroscopic DMC/SMC supports. The panel shall be manufactured in conformance to requirements of local electrical inspector and it shall be contractors responsibility to get initial approval of drawings and also final approval of complete electrical works related to this section. The minimum clearances between bus bars shall be as follows : Phase to phase - minimum 20mm Phase to neutral-minimum 15mm Main L.T. Panel Incoming : One (1) No800 Amp. 4 pole ACB of 50 KABreaking capacity MDO Type Metering : One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. One (1) No. (0-800A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc. One (1) Set of Phase Indication Lamp. Bus Bar : One (1) No. 800 Amp.TPN aluminimum bus bar of suitable length. Outgoing : Phase indication lamps on each outgoing to be provided. 630 Amps TP MCCB of 25KA (Ics=Icu) Breaking Capacity- 1 No 320 Amps TP MCCB of 25KA (Ics=Icu) Breaking Capacity- 1 No 32 Amps SP MCB of 10KA (Ics=Icu) Breaking Capacity- 2 No 6 Amps SP MCB of 10KA (Ics=Icu) Breaking Capacity- 1 No 630 Amps TP MCCB of 25KA (Ics=Icu) Breaking Capacity- 1 No Spare 320 Amps TP MCCB of 25KA (Ics=Icu) Breaking Capacity- 1 No Spare 63 Amps TP MCB of 10KA (Ics=Icu) Breaking Capacity- 1 No Spare
107FEEDER PILLER-1 Supplying assembling erecting connecting, testing and commissioning of sizes of 3.15mm thick sheet metal enclosed outdoor type feeder pillars with water proof dust and vermin proof hinged and lockable doors including rain protection cover complete with interconnections, with aluminium wire, tapes, bonding to earth and painting complete as required.The feeder pillar shall consist ofMCCB as incoming and MCCB/MCB as outgoing. (Note : This panel shall be a FRONT operated, with cable entry from the top/bottom.The fault with standing capacity shall be 10 KA.Earth busbar shall be part of the L.T. Panel). INCOMING 1No. Of 320 Amps TPN MCCB of 25KA service breaking capacity and 320 Amp trip setting. BUS BAR 1 Set of 320 Amps TPN Aluminium Bus Bars of suitable length and of cross section . Bus bar shall be insulated by heat shrinkable sleaves & clip on shrouds for joints.Bus bar shall be designed to with stand a fault level of 25 KA at 415 volts. 3Nos. Phase indicating lamp each lamp shall have one toggle switch . OUTCOMING 200Amp TPMCCB (25kA) - 1 Nos. 63Amp TPMCB (10kA) - 1 Nos. 40Amp TPMCB (10kA) - 2 Nos. 63Amp SPMCB (10kA) - 1 Nos. 32Amp SPMCB (10kA) - 2 Nos
108TELEPHONE SYSTEM Supply ofMODULAR BOXES, BASE & COVER PLATE :- Supplying following size/modules, GI box along with modular base& cover plate for modular switches in recess etc as required. • 1 or 2 Module (75mm X 75 mm)
109Supply ofMODULAR TYPE SWITCH / SOCKET :- Supplying following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required. • Telephone socket outlet
110TV antenna socket outlet
111Supplyingoftelephone wire following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 2 Pair
112Supplyingof10 pair Junction Boxes for Floors and building with Krone connectors , with connection and punching of same
113Supplyingof co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
114MISCELLENEOUS Supply of Ceiling Fan with fan motor of A.C Permanent insulation, capacitor rating conforming BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment. The rated voltage 220/240 volts, 50Hz, 1-ph AC the fan assemble should consists of down road blades, shackle canopies etc and with double ball bearing system. BEE 5 Star rated-1200mm sweep
115Supplyingof following size of preforated pre-painted M.S. cable tray with perforration not more than 17.5% in convenient sections, jointed with connector, suspended from the ceiling with M.S. Suspender including bolts & nuts, painting suspenders etc. as required 100mm width X 50 mm depth X 1.6mm thickness.
116150mm width X 50 mm depth X 1.6mm thickness.
117Supplyingof unplastisized rigid PVC pipe conforming to IS:13592 type A including jointing , cuttingand making good the walls & floors as per requirement. 150mm
118Supplyingof AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required 300mm sweep.
119Supply of AC 600mm Sweep, 230/250 Volts, 50 Hz Air Circulator connection etc. complete as required
120Supplyingof Three phase electronic energy meter
121Supplyingof following Dia RCC Pipe NP 2 Class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 ( 1 Cement : 2 fine sand)including trenching ( 75 cm) deep and refilling etc. as required. 100mm dia
122150mm dia
123Supplyingof material for following size of Cable Chamber made of 230 mm thick brick work in cement mortar (1 cement : 6 sand) with PCC 100 mm thick PCC base plastering of inner and outer surface with cement mortar including providing of Heavy Duty C.I Cover complete with digging, refilling and removal of surplus soil complete as required. 600 mm x 600 mmx 800 mm deep
124900 mm x 900 mmx 1000 mm deep
125EXTERNAL LIGHTING Supplying steel tubular pole 9 Meter long designated 410 SP-27 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respects
126Painting of the electric pole with 2 coats of aluminium paint over red oxide primer complete in all respects.
127Supplyof LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 52 watt to 72 Watt. Confirming to IP66 Protection complete in all respect.CAT-AAA
128Supply of Bakelite sheet 3 mm thick of suitable size & connector
129Supply of 6 Amp to 32 Amp DP MCB (10KA) (Legrand Lexic) for poles
130Supplyfollowing capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contractors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN complete in all respect. 40 Amp SPN
131Supplying of gate light fixture fabricated out of M.S. Pipe 4.05mm thick 75mm dia 0.5m long in cement concrete foundations 1:3:6 complete with 1 No. Crompton SPT 1107 IL/BM or Equivalent with 70W Sodium vapour lamp complete with all accessories in outdoor type control gear box necessary civil work marshelling box having two no. three way brass connector, one no. 15 amps kit kat fuses, cable glands, earthing stud, necessary interconnections and 40mm dia GI Pipe "B" Class for protection of the upright cable and painting etc. as required. Make: Philips Cat No. HPC 104 spc 104 1xson 70 w E
132SAFETY EQUIPMENTS Supplying of Fire buckets, round bottom made of G.I. Sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-charge.
133Supplyingof 1800 mm x 900 mm X 12 mm thick chequered rubber matting of tested quality
134Supplyingof danger board fabricated from 10 gauge MS sheet as per IE Rules
135Supplyingof shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board or soft board for proper completion of work.
136Supplyingof fire extinguishers, ABC Type 4.00 kg. capacity(ISI Marked IS : 15683 & TAC approved)complete with initial charges and wall bracket, along with supply of all materials for proper completion of work.
137Supplyingof CO2 typefire extinguishers, 4.50 kg. capacity(ISI Marked IS : 2878 & TAC approved)complete with initial charges and wall bracket, along with supply of all materials for proper completion of work.
138Supplying, Testing and Commissioning of AMF start 320KVA DG set totally enclosed in an sound proof Acoustic Enclosure (As Per CPCB Norms) comprisiing of diesel engine of suitable BHP directly coupled with alternator capable to deliver 320KVA, 415 Volt, 50Hz, 3 phase, AC Supply at 0.8 power factor mounted on a common base frame complete in all respect with generator control panel with metering equipments, all required safety devices, fittings, batteries, battery leads and other accessories, diesel oil fuel tank of 250 Ltrs. capacity, fuel piping valves, filters, supports, control and power cables from DG Set to AMF Panel having residential type sliencer, exhaust piping with asbestos roping, antivibration mounting pads first filling of lub oil, complete as per specifications and conditions earth connections etc. as reqd. Incl.Packing, Insurance, transporation, Loading and Unloading charges Testing on load i/c load arrangement charges with T&P, high speed diesel oil and initial lubricating oil filling Make : Jackson
139Supplying, Testing and Commissioning of315 KVA Transformer Incl. Transportation charges upto site.