Construction Of Material Recovery Facility Centerat Sarkar Thottam Komburan Kadu In Mettur Municipality-Earth Work Excavation For Foundation In Hard Stiff Clay, Stiff Black Cotton, Hard Red Earth, Shales Murram, Gravel, Stoney Earth And Earth Mixed With Small Size Boulders Ss.20B And Sand, Silt Or Other Loose Soil, Wet Sand Or Silt Not Under Water, Light Black Cotton Soil, Sandy Loam Ordinary Soil And To Full Depth As May Be Directed Except In Hardrock Requiring Blasting Inclusive Of Shoring Shuttering And Baling Out Water Wherever Necessary Refilling The Sides Of Foundation With Excavated Soil Otherthan Sand In Layers Of 15Cm Thick Well Rammed And Cleaning And Levelling The Site Etc., Complete- Narrow Foundations - First Depth - Upto 2M 2 Earth Work Excavation For Foundation In Hard Stiff Clay, Stiff Black Cotton, Hard Red Earth, Shales Murram, Gravel, Stoney Earth And Earth Mixed With Small Size Boulders Ss.20B And Sand, Silt Or Other Loose Soil, Wet Sand Or Silt Not Under Water, Light Black Cotton Soil, Sandy Loam Ordinary Soil And To Full Depth As May Be Directed Wherever Necessary Refilling The Sides Of Foundation With Excavated Soil Other Than Sand In Layers Of 15Cm Thick Well Rammed And Cleaning And Levelling The Site Etc., Complete- Open Earth Work Excavation 3 Plain Cement Concrete 1:4:8 ( One Cement, Four Sand, Eight Aggregate ) Using 40Mm Gauge Hardbroken Granitestone Jelly For Foundation Including Dewatering If Foundnecessary And Laid In Layers Of Not More Than 15Cmthick And Compacted, Etc., Complete Complying Withstandard Specfication. 4 Supplying And Erecting Steel Centering Including Necessary Supports For Plane Surfaces For Reinforced Cement Concrete Works Such As Column Footings, Column Pedestals, Plinth Beams, Grade Beams, Staircase Steps, Etc. Which Require Only Nominal Strutting Using Mild Steel Sheets Of Size 90Cm X 60Cm And 10 Bg Stiffened With Welded Mild Steel Angles Of Size 25Mm X 25Mm X 3 Mm For Boarding, Laid Over Silver Oakjoists Of Size 10Cm X 6.5Cm Spaced At About 75Cm Centre To Centre Or At Suitable Intervals Etc. Complete In All Floors Complying With Standard Specifcation - Plinth Beam 5 Supplying And Erecting Centering For Sides And Soffits Including Necessary Supports And Strutting Upto 3.29 M Height For Plane Surfaces As Detailed Below In All Floors With All Cross Bracings Using Mild Steel Sheets Of Size 90 X 60 Cm And 10 Bg Stiffened With Welded Mild Steel Angle Of Size 25Mm X 25Mm X 3 Mm For Boarding Laid Over Silver Oak Joists Of Size 10Cm X 6.50 Cm Spaced At Abote 90 Cm Centre To Centre And Supported By Casurina Props Of 10Cm To 13 Cm Dia Spaced At Not More Than 75 Cm Centre To Centre Etc. Complete Complying With The Standard Specificaiton. - For Plane Surfaces Such As Rcc Floor Slab, Roof Slab, Beams, Lintels, Bed Blocks, Landing Slab, Waist Slab, Portico Slabs And Beams, Etc. 6 Providing And Laying In Position Standardised Concrete Mix M-20 Grade In Accordance With Is 456 - 2000 Using 20Mm And Down Graded Hard Broken Granite Stone Jelly For All Rcc Items Of Works With Minimum Cement Contenet Of 325Kg / Cum And Maximum Water Cement Ratio Of 0.55 Including Admixture ( Plasticiser / Super Plasticiser ) In Recommended Proportions As Per Is 9103 To Accelerate, Related Setting Of Concrete, Improve Workability Without Imparing Strength And Durability With About ( 5.0Cum ) , 7730Kg Of 20Mm Machine Crushed Stone Jelly And With About ( 3.3 Cum ) , 5156Kg Of 10 - 12Mm Machine Crushed Stone Jelly And With About ( 4.79Cum ) 7670 Kg Of Sand, But Excluding Cost Of Reinforcement Grill And Fabricating Charges Centering And Shuttering But Including Laying, Vibrating With Mechanical Vibrators, Finishing, Curing, Etc And Providing Fixtures Like Fan Clamps In The Rcc Floor / Roof Slabs Wherever Necessary Without Claiming Extra Cost Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers - The Coarse And Fine Aggregates To Be Used Should Comply With The Requiremnents Of Is Staandards. ( No Separate Payment Will Be Made By The Department For The Excess Usage Of Materials ) 7 Suppling And Fabricating And Placing In Position Ms ( Or ) R.T.S. Bar For Reinforcement To All Rcc Works As Per The Design Given Including Cost Ofsteel And Binding Wire Also In All Floors As Per Standard Specification. 8 Brick Work In Cm 1:5 ( One Cement & Five Sand ) Using Ii Class Ground Moulded Bricks Of Size 9X43 / 8X 2 3 / 4 Including Finishing, Curing, Etc., Complete Complying With Standard Specification 9 Plastering With Cement Mortar 1:5 ( One Cement, Five Sand ) 12Mm Thick In All Floors Including Cost And Conveyance Of All Materilas To Site And Labour Charges Etc, Complete As Per Standard Specifications. 10 Plastering With Cement Mortar ( 1:4 ) 20Mm Thick In All Floors Including Cost And Conveyance Of All Materials To Site And Labour Charges Etc, Complete Complying With Standard Specifications ( S.I.309 ) 11 Supply And Fixing Of M.S Wire Mesh With One Coat Of Red Oxide With Primer Including All Costs Such As Welding, Grinding And Fabrication Charges, Cost And Conveyance Of All Materials To Site Etc, Complete As Per Standard Specification. 12 Painting Two Coats With Ready Mixed Plastic Emulsion Paint Approved Quality And Colour Over A Priming Coat, Including Thorough Scrapping, Clean Removal Of Dirt, Etc Complete And Including Necessary Plaster Of Paris, Putty, Wherever Required Etc, Complete As Per Standard Specification. 13 Supplying And Erecting Pull And Push Type Rolling Shutter With I.S.I. Make Of Approved Size And Section Using 18 Gauge G.I.Sheet With Manually Operated Type. The Shutter Shall Be Painted With One Coat Of Red Oxide Primer And The Rate Is Inclusive Of Hood Covers, Transportation Charges Etc, Complete As Per Standard Specification. 14 Paintingwith Ready Mixed Enamel Paint Over The New Iron Works Of Approved Quality And Colour Without Priming Coatincluding The Cost All Materials Etc., Complete, In All Floors. 15 Supplying, Fabricating, Erecting Structural Steel Work For Roofing Welded Or Bolted Type Using Ms Channels, Angles, Plates And Round Bars Etc. Conforming To Is Specification Including Primer Coating And Enamal Painting As Per Design Given By The Departmental Officers Etc, Complete As Per Standard Specification 16 Supplying And Fixing In Position Of Best Approved Colour Design And Quality Frp Sheets Of 1.5Mm Thick With Necessary U Or J Bolts, Bitumen Washers And Cutting The Frp Sheets To The Required Size.Etc. Complete. 17 Plain Cement Concrete 1:2:4 ( One Cement, Two M Sand And Four Hard Broken Stone Jelly ) Using 20Mm Jelly For Wearing Coat Including Laying, Compacting, Finishing And Curing, Etc., Complete As Per Standard Specificatins And As Directed By The Departmental Officers. 18 Wiring With 2 X 1.5 Sqmm ( 22 / 0.3 ) Pvc Insulated Single Core Unsheathed Copper Conductor Cable Of 1100V Grade In Suitable Pvc Rigid Pipe Concealed In Wall And Ceiling With Pvc Accessories Inflush With Wall With 3Mm Thick Hylum Sheet Cover With Tw Switch Box And 5A F.T. Switch With Continuous Earth Wire Connection Of 14 Swg Tc Wire For Making Good For Pvc Open Light Point / Fan Point ( For Electronic Regulator ) Etc, Complete As Per Standard Specifications. Sd 22 19 Supply And Fixing Of Single Box Type 436 W Flu Fitting Complete With Electronic Ballast And Condensor With Tw Round Blocks On Wall Or Ceiling With Flu Tube With Pvc Unsheathed Copper Leads From Terminals To The Fitting Etc, Complete As Per Standard Specificationssd 87 20 Supply And Run Of 2 Of No.8 Swg Gi Wire For Guarding With Cradle With No.8 Swg Gi Wire At The Equal Interval Of 1.5M Etc, Complete As Per Standard Specifications Sd.75 21 Wiring With 2 X 4Sqmm ( 56 / 0.3 ) Pvc Insulated Single Core Unsheathed Copper Conductor Cable Of 1100V Grade In Suitable Pvc Rigid Pipe Concealed In Wall And Ceiling With Pvc Accessories Inflush With Wall With 150 X 100 X 113 Mm Tw Switch Box With 3Mm Hylum Sheet Cover For15a 3 Pin Non Inter Locking Cs Plug With Continuous Earth Wire Connection Of 14 Swg Tc Wire For Open Pvc Power Plug Point.Sd 41 22 Supply And Fixing Of Tneb Board Suitable For 3 Phases 63A Service Connection Made Up Of Suitable Angle Iron Frame Work Of Size 2 Feet X 1 1 / 2 Feet Using Angle Iron Of Size 1 1 / 2 X 1 1 / 2 X 1 / 4 Rigidly Fixed On Wall Covered With Hylem Sheet Of Size 2 Feet X 1 / 2 Feet Of 6Mm Thickness With Necessary Bolts And Nuts Supports And Supply And Fixing Of 3 Nos 63A Fuse Units ( 500V ) 1 No. Neutral Link, Copper Earth Flat Of Size 1 X 1 / 4 With Inter Connection Of Eb Meter To Fuse Units By 7 / 16 Pvc Insulated Copper Wire With Earth Connection Complete.Sd 129 23 Supply And Delivery Of Sorting Table 24 Supply And Delivery Of Electronic Weighing Scale 2000Kg Capacity