Bidhan Chandra Krishi Viswavidyalaya has published Tender For In Vitro Mutagenesis Of Stevia For Enhanced Production Of Steviol Glycosides. Submission Date for this Tender is 20-01-2023. Rolling Hardware Tenders in mohanpur West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

35603481
Tender For In Vitro Mutagenesis Of Stevia For Enhanced Production Of Steviol Glycosides
Open Tender
Indian
West Bengal
mohanpur
20-01-2023

Tender Details

In Vitro Mutagenesis Of Stevia For Enhanced Production Of Steviol Glycosides- Equipment Purchase For Scientific Research , Particulars , Fully-Automated Microtome : It Should Have Precise Stepper Motor And Drives Which Ensure Accurate Specimen Advance And Maintenance Free Cross Roller Guide Ways Which Provides Greater Stability During Sectioning. • It Should Have A Powerful Sectioning Motor And Sectioning Speed Can Also Be Adjusted. • Lcd Screen Displays Section And Trimming Thickness, Number Of Sections Cut Travel. Trimming Thickness, Sectioning Thickness, Fast Forward And Fast Backward Movement Can Be Controlled Through Feather Touch Keypad. The Hand Wheel Should Have Lockable In Any Position, Huge Volume Waste Tray. It Should Have An Integrated Safety Alarm System And Emergency Stop Button. • It Should Have Section Thickness Range 0.5-200?M. ( To Set Up To 200?M, 200?M, Can Change As Per Requirement. ) • It Should Have Section Thickness Setting 0.5-5?M, In 0.5?M Increment 5-20?M, In 1?M Increment 20-60?M In 5?M Increment 60-100?M In 10?M Increment 100-200?M In 20?M Increment • Trimming Thickness Setting1-800?M. ( You Can Set Any As Per Your Requirement ) • Setting Values- 1-10?M In 1?M Increment 20-50?M In 5?M Increments 50-100?M In 10?M Increment 100-600?M In 50?M Increment 600-800?M In 100?M Increment • It Should Have Sectioning Modes: 4 Continuous, Step, Programmed, Manual. • It Should Have Horizontal Feed28mm. • It Should Have Vertical Specimen Stroke60mm • Sectioning Speed Adjustable, 3 Different Speeds. Slow, Medium And High • Specimen Retraction 5-100?M In 5?M Increments, Can Be Turned Off • Max Specimen Size 50X50 Mm.• Specimen Orientation Horizontal 8°, Vertical 8°, Z 360°• Nominal Supply Voltages 110 / 220 V Ac ± 10%. • Nominal Frequency 50 / 60 Hz • Dimensions Basic Instrument 590 X 345 X 290 Mm ( W X D X H ) • Ce Certified Product From European Notified Body And It Should Be Usfda Registered.• Iso 9001 And Who Gmp Certified Manufacturer On-Site Warranty: Minimum 2 Years , Cooling Incubator-Shaker : Capacity: 113 Lit. 4 Cu. Ft. Cap., Shaker Cap.: 250 Ml X 9 Flasks & 100 Ml X 9 Flasks, Inner & Outer Being Made Of Ss Sheet, Temp. Range 5°C - 60°C, Controlled By Digital Indicator Cum Controller, Accuracy Of + / - 0.5C. 1 No. Shaker Constructed At The Bottom Of The Working Chamber With Speed Control, Shaking Speed 50 - 250 Rpm. Provided With A Motorized Fan Blower. 230 V. Ac. The Manufacturer Should Have A Service Set-Up At Kolkata & Those Document Needs To Be Enclosed Along With Your Bid. Manufacturer Should Submit Their Factory License Certificate Along With Their Bid. Ce & Iso ( 9001 : 2015 & 13485 : 2016 ) Approved On-Site Warranty: Minimum 2 Years

Key Value

Document Fees
Refer document
EMD
INR 1500.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: In vitro mutagenesis of Stevia for enhanced production of steviol glycosides
Sl. No. Item Description
1Particulars
2Fully-automated microtome : It should have precise stepper motor and drives which ensure accurate specimen advance and maintenance free cross roller guide ways which provides greater stability during sectioning. • It should have a powerful sectioning motor and sectioning speed can also be adjusted. • LCD screen displays section and trimming thickness, number of sections cut travel. Trimming thickness, sectioning thickness, fast forward and fast backward movement can be controlled through feather touch keypad. The hand wheel should have lockable in any position, huge volume waste tray. It should have an integrated safety alarm system and emergency stop button. • It should have Section Thickness Range 0.5-200µm. (To set up to 200µm, 200µm, can change as per requirement.) • It should have Section Thickness Setting 0.5-5µm, in 0.5µm increment 5-20µm, in 1µm increment 20-60µm in 5µm increment 60-100µm in 10µm increment 100-200µm in 20µm increment • Trimming thickness setting1-800µm.(You can set any as per your requirement) • Setting Values- 1-10µm in 1µm increment 20-50µm in 5µm increments 50-100µm in 10µm increment 100-600µm in 50µm increment 600-800µm in 100µm increment • It should have sectioning modes: 4 continuous, step, programmed, manual. • It should have Horizontal feed28mm. • It should have Vertical Specimen Stroke60mm • Sectioning Speed Adjustable, 3 different speeds. Slow, medium and high • Specimen Retraction 5-100µm in 5µm increments, can be turned off • Max Specimen Size 50x50 mm.• Specimen Orientation Horizontal 8°, Vertical 8°, z 360°• Nominal Supply Voltages 110/220 V AC ± 10%. • Nominal Frequency 50/60 Hz • Dimensions basic instrument 590 x 345 x 290 mm (W x D x H)• CE certified product from European notified body and it should be USFDA registered.• ISO 9001 and WHO GMP certified manufacturer On-site warranty: Minimum 2 years
3Cooling incubator-shaker : Capacity: 113 Lit. 4 Cu. ft. Cap., Shaker Cap.: 250 ml x 9 flasks & 100 ml x 9 flasks, inner & outer being made of SS sheet, Temp. Range 5°C - 60°C, controlled by Digital Indicator Cum Controller, accuracy of +/- 0.5"C. 1 No. Shaker constructed at the bottom of the working chamber with speed control, Shaking speed 50 - 250 RPM. Provided with a motorized fan Blower. 230 V. AC. The Manufacturer should have a service set-up at Kolkata & those document needs to be enclosed along with your bid. Manufacturer should submit their factory license certificate along with their bid. CE & ISO (9001 : 2015 & 13485 : 2016) approved On-site warranty: Minimum 2 years