Tender For Design, Engineering, Procurement, Construction, Redevelopment And Refurbishment Of Dada Sukhendra Singh Stadium And Maintenance Of Entire Facility For A Period 3 Years Including 3 Years Defect Liability Period At Satna, Madhya Pradesh, satna-Madhya Pradesh

Municipal Corporation-MC has published Tender For Design, Engineering, Procurement, Construction, Redevelopment And Refurbishment Of Dada Sukhendra Singh Stadium And Maintenance Of Entire Facility For A Period 3 Years Including 3 Years Defect Liability Period At Satna, Madhya Pradesh. Submission Date for this Tender is 11-02-2023. Building Work Tenders in satna Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

35601607
Corrigendum : Tender For Design, Engineering, Procurement, Construction, Redevelopment And Refurbishment Of Dada Sukhendra Singh Stadium And Maintenance Of Entire Facility For A Period 3 Years Including 3 Years Defect Liability Period At Satna, Madhya Pradesh
Open Tender
Indian
Madhya Pradesh
satna
11-02-2023

Tender Details

Design, Engineering, Procurement, Construction, Redevelopment And Refurbishment Of Dada Sukhendra Singh Stadium And Maintenance Of Entire Facility For A Period 3 Years Including 3 Years Defect Liability Period At Satna, Madhya Pradesh

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-Jan-2023 Tender Notice Other 04-02-2023
2 03-Feb-2023 Ammendment 01 Other 04-02-2023
3 04-Feb-2023 Ammendement Key Dates Date 11-02-2023

Key Value

Document Fees
INR 20000 /-
EMD
INR 728000.0 /-
Tender Value
INR 7.27 Crore /-

BOQ Items

Name of Work: Design, Engineering, Procurement, Construction, Redevelopment and Refurbishment of Dada Sukhendra Singh Stadium and Maintenance of entire facility for a period [3]Three Years including 3 [Three] years defect liability period at Satna, Madhya Pradesh.
Sl. No. Item Description
1EARTH WORK
2Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15cm deep and disposal of rubbish, lead upto 50 m and lift upto 1.5 m.
3Carriage of material By Mechanical Transport including loading, unloading and stacking Carting away of excavated earth up to 10 KM lead
4Demolishing & Dismantling
5Demolishing cement concrete manually/by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in Charge
6Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix).
7Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in Charge.
8Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in Charge.
9In cement mortar.
10Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in Charge:
11In cement mortar.
12Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
13Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
14Of area 3 sq. metres and below.
15Dismantling wooden boardings in lining of walls and partitions,excluding supporting members but including stacking within 50 meters lead :
16Thickness above 10 mm up to 25 mm
17Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
18Redevelopement of DSS
19Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means /manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed.
20All kinds of soil
21Brick work with well burnt chimney bricks in bulls patent trench kiln manufactured by ghol process, crushing strength not less than 40 kg/sq cm and water absorption not more than 15% in foundation and plinth. Cement mortar 1:4 (1 cement : 4 coarse sand)
22Cement mortar 1:4 (1 cement : 4 coarse sand)
23Filling by available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
24Cement Concrte work for sitting arrangements (Sitting Steps First Floor consider 50% for risers)
25Cement concrete flooring M-15 (nominal mix) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm maximum size of stone aggregate. (New Sitting arrangement)
26Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete (New Sitting arrangement)
27Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer"s specifications including appropriate priming coat, preparation of surface, etc. complete. (New Sitting arrangement)
28Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
29Cement concrete grade M-10 (Nominal Mix) with 20mm maximum size of stone aggregate
30Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/Cum. Excess/less cement used as per design mix is payable/recoverable separately).
31All work up to Plinth level
32All work above Plinth level up to floor 2 level
33Centering and shuttering including strutting, propping etc. and removal of form for :
34Foundations, footings, bases of columns, etc. For mass concrete.Sides of bottom
35Centering and shuttering including strutting, propping etc.and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts.
36Centering and shuttering including strutting, propping etc.and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers.
37Centering and shuttering including strutting, propping etc.and removal of form for :Suspended floors, roofs, landings, balconies and access platform.
38Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete.
39Thermo-Mechanically Treated bars. (TMT/TMX) FE 500 or more conforming to IS 1786
40Brick work with chimeny brick of class designation 40 in superstructure above plinth level upto floor 2 level including the cost of scaffolding in :
41Cement mortar 1:4(1 cement : 4 coarse sand)
42Half brick masonry with open bhatta of class designation 25 in super structure above plinth level up to floor 2 level including the cost of scaffolding.
43Cement mortar 1 : 4 (1 cement : 4 coarse sand)
44Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position : Second Class Teak wood
45Providing and fixing panelled or panelled and glazed wooden shutters for doors, windows and clerestory windows including ISI marked M.S pressed bright finished butt hinges with necessary screws excluding, panelling / glazing which will be paid for separately. 35 mm thick shutters second class teak wood
46Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (PartI) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters using following hinges.
4735mm thick including ISI marked Stainless Steel butt hinges with necessary screws. (for proposed WC Cubicles)
48Providing andfixingaluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriateZsectionsand othersections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or withfixingclips,orwithexpansionhold fasteners including necessary filling up ofgaps at junctions,at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and thedirections of Engineer-in-charge. (Glazing and paneling to be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron)
49Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in- charge (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness
50Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Single rubber stopper
51Providing and fixing bright finished brass 100 mm mortice latch and lock ISI marked with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles with necessary screws etc. complete (Best make of approved quality).
52Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125mm
53Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete.
54Fixed to openings /wooden frames with rawl plugs screws etc.
5512 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
5615mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand)
57Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade
58Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm).
59Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
60Providing and laying vitrified floor tiles (without Soluble salt) or printed (with soluble salt) Nano polished (Glossy finish) in different sizes with water absorption less than 0.05% and conforming to IS : 15622 of approved make in all colours & shades, Ist quality/ premium quality in flooring laid on 20mm thick cement mortar 1:4 (1 cement : 4 sand) including grouting the joints with white cement and matching pigments etc. complete. Size 600x600mm as per manufacturer specification.
61Providing and laying rectified Glazed Ceramic floor tiles 300x300 mm or more (8mm to 10mm thick) of 1st quality conforming to IS : 15622 of approved make in and colours laid on 20mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigments etc., complete.
62Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (6 to 7mm thick) of approved make in all colours, shades of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry including pointing in white cement mixed with pigment of matching shade complete.
63Providing & fixing corrugated Galvanised steel (CGS)sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on over lapping of sheets complete (upto any pitch in horizontal / vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00mm thick with zinc coating not less than 275gm/m²
64Steel work in built up M.S.tubular section (round, square or rectangular Hollow tube etc.trusses / frame work etc./railing work etc. including cutting, hoisting fixing in position and applying a priming coat of approved steel primer,welded and bolted including special shaped washers etc. complete. Hot finished welded type tubes.
65Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps.
66Providing and fixing CP brass waste coupling of approved quality and make for sink and wash basin. Waste coupling 38mm of 83mm length and 77mm breadth, weighing not less than 60gms.
67Providing and fixing PTMT soap Dish Holder having length of 138mm,breadth 102mm,height of 75mm with concealed fitting arrangements. Weighing not less than 106 gms.
68Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing and fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to
69Providing and fixing in position best Indian Health Faucet with 8mm dia 1 meter long Flexible Tube and wall bracket with N. R. V. (non-return valve).(Premium Range Sanitary Ware)
70Providing and fixing PTMT bib cock of approved quality and colour.15 mm nominal bore, 165mm long. Weighing not less than 110 gms.
71Providing and fixing toilet paper holder :C.P. brass
72Providing and fixing in position best Indian Auto Closing 32mm, Flush valve (for W. C. European and Wall Hung Type) concealed type (with DECOL technology/cartridge). (Premium Range)
73Providing and fixing UPVC trap of self cleaning design complete. Including cost of cutting and making good the wall and floors. 100 mm inlet and 75 mm outlet
74Providing and fixing uPVC soil and waste pipes conforming to IS:13592 Type B including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.Single socketed pipes for working pressure of 4 kg/sqcm. (straight type syphon uPVC WC pan connecter with neoprene rubber ring) and necessary accessories etc.,complete- 110mm dia minimum wall thisckness 3.2mm
75Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water ( 250 ml and 500 ml consumption), having water inlet from back side, including fixing to wal
76Providing & Fixing 8mm thick froasted Urinal glass partition size 900x450mm brass made bracket with. (Premium Range)
77Providing and Laying Mexican/Zyosia carpet grass Turf with earth 50mm to 60mm thickness on existing ground prepared with proper level and ramming with tool swooden (Durmuth) and then rolling the surface with light roller make the surface smoothen and light watering with sprinkler and maintenance for 30 days or more till the grass establishes properly, as per direction of Engineer-in-Charge.
78Construction of granular sub-base by providing Coarse graded material (CBR>30), spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method at OMC and compacting with vibratory roller of 80-100KN Static weight to achieve the desired density, complete in all respect as per relevant clauses of section-400.
79Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam including pre mixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density and as per relevant clauses of section-406 of the specifications.
80Providing and laying dense bituminous macadam with hot mix plant batch using crushed aggregates of specified grading, pre mixed with bituminous binder, transporting the hot mix to work site, laying with mechanical paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction complete in all respects and as per relevant clauses of section-505. (Lime or cement will be used as filler) for Grading I ( 75-100mm thickness ) bitumen content 4.0% (VG-30)
81Providingandlaying bituminousconcrete withhotmixplantusing crushedaggregatesofspecifiedgrading,premixedwithbituminous binder,transportingthehotmixtoworksite,layingwithamechanicalpaver finishertotherequiredgrade,levelandalignment,rollingwithsmooth wheeled,vibratoryandtandemrollerstoachievethedesiredcompaction inallrespectsandasperrelevantclausesofsection-507.(limeorcement will be used as filler). for Grading I ( 50 mm thickness ) , bitumen content 5.2% (VG-30)
82LT Panel (PCC) & Accessories: Panel Enclosure: SITC of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel made out of CRCA sheet, required hardware, duly painted by two coats of zinc/ red oxide primer followed by Powder coated/ epoxy/ PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/ switchgear. Thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be of 2.0mm above 600mm. Load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel, if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator).
83Aluminium Bus Bar Supplying and fixing of Aluminiumbus bar by means of SMC/ DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending, cutting in required shape and size and colour coding with heat shrinkable PVC sleeves.
84Incomer/(s):- SITC of quick make and quick break 4 POLE current limiting MCCB having following current rating, short circuit breaking capacity at 440/ 415 V, 50 Hz; O/L & S/C settings and conforming to IS 13947-2/ IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR, shunt trip, earth fault trip, push (test) to trip, including making connections with lugs/spreaders etc. as required (With Microprocessor Release) 630 Amp , 35/ 50 kA, adjustable O/L & adjustable S/C (1 no for Mains supply & 1 no for DG supply/ or 1 no changeover arrangement at DG Control panel)
85MCCB Accessories: Supply and fixing of following accessories for MCCB Shunt Trip Rease
86SF of CT operated direct reading type Ampere meter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Analog type (96 mm x 96 mm ) - 1 no for each incomer
87SF of Current Transformer, with all necessary support in existing panel including connection etc. as required. from 500 / 5 to 1600/ 5 Ratio , 15 VA , class 1 accuracy (Set of 3 nos each for Mains & DG supply incomer)
88SF of Current Transformer, with all necessary support in existing panel including connection etc. as required. from 500 / 5 to 1600/5 Ratio , 15 VA , class 1 accuracy (1 no for APFC load sensing ckt)
89SF of CT linked selector switch of 10A for Ampere meter (4 position) including making connection etc. as required. (1 no for each Ameter)
90Phase Indicating Lamps- Supply & fixing of 240/ 220 V, LED (22.5 mm dia) Pilot lamp with integral circuit, terminal block, including connection etc. as required. Red/ Yellow/ Blue (Set of 3 nos for each incomers)
91P & F of energy analyser (multy function energy meter) with LCD/ LED display capable of minimum 20 numbers electrical parameters display with 1A/5A CT input for LV/ HV network, RS 485 communication port etc. complete in all respect. (1 no for each Incomer)
92P & F of No Load Compansation KVAR banks (APP type) with detuned filters, MCCB, Power Contractor , Auto/ manual control with switching on delay timer, housed in lower most compartment of incomer/ buscoupler module(s). KVAR bank, selected based on kva rating of associated transformer(s), shall be of following capacity. 15 kVAR (APP Type)
93Outgoing/(s): SITC of quick make and quick break 3 POLE current limiting MCCB having following current rating, short circuit breaking capacity at 440/ 415 V, 50 Hz; O/L & S/C settings and conforming to IS 13947-2/ IEC 60947-2 with front face and centralised adjustable, line load interchangeability, having positive isolation capability, provision for UVR, shunt trip, earth fault trip, push (test) to trip, including making connections with lugs/spreaders etc. as required (With Thermal Magnetic Release) up to 100 Amp, 16/ 25 kA, adjustable O/L & fixed S/C setting
94160 Amp, 25 kA, adjustable O/L & fixed S/C setting
95250 Amp, 35/ 40 kA, adjustable O/L & fixed S/C setting
96ON/ OFF Indicating Lamps- Supply & fixing of 240/220 V, LED (22.5 mm dia) Pilot lamp with integral circuit, terminal block, including connection etc. as required. Red/ Green (Set of 2 nos for each outgoing)
97LV APFC Panel: Supply, installation, testing & commissioning LV APFC panel consisting of required capacitor banks for continuous duty to improve P.F. 0.85 to 0.99 in required steps enclosed in dust & vermin proof compartment, indoor type, fabricated from CRCA sheet steel with minimum thickness of 3 mm for base frame/ channel/ gland plates, 2.0 mm for load bearing members/ doors & 1.6 mm for internal partitions, minimum degree of protection - IP 42, busbar chamber, required size of Al bus bar/ terminals, minimum 10 stage APFC relay, metering, indicating lamps, push buttons, with detuned reactor complete as per IS: 16636-2017 with latest amendment & detailed technical specification and data sheet as under. Up to 50 KVAR capacity APFC panel consisting following items. a) 125 A, 50 kA for 1sec. TP, TM based MCCB with spreader terminals & rotary handle b) 0-125 A range analogue ammeter of 96 x 96 mm size with selector switch c) 3nos. 125/ 5A, 10 VA CL-1.0 cast resin type current transformer d) Suitable rating MCCB/ MCB &Contactors for each capacitor bank. e) Suitable rating APP type capacitor banks (vacuum impregnated with non-PCB/ non toxic oil, internally delta connected with built in internal fuses complete with discharge resistances & terminal cover) of approved make in required steps with well suited detuned reactor is placed in series with each capacitor step. f) Enclosure dimensions- 1600 (H) x 1150 (W) x 600 (D)
98Industrial Power Sockets: Supplying and fixing 30A, 415V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
99Internal Illumination System (Indoor Stadium, Admin/ Office, Canteen, Rooms & Toilet Blocks etc: Lighting Distribution Boards: (Location - Indoor) Supplying of approved make TPN MCB DB Metal Double Door IP 43 protection with provision for FP MCB/ Isolator/ RCCB/ RCBO as incomer and SP MCBs as outgoing inclusive of Bus bar, Neutral bar, Earth bar & two earth terminals etc. complete as per IS:13032 (exclusive of MCB & isolator); 4way (8 +12)
100Supplying of approved make TPN MCB DB Metal Double Door IP 43 protection with provision for FP MCB/ Isolator/ RCCB/ RCBO as incomer and SP MCBs as outgoing inclusive of Bus bar, Neutral bar, Earth bar & two earth terminals etc. complete as per IS:13032 (exclusive of MCB & isolator); 8way (8 +24)
101Labour charges for fixing sheet steel enclosures, MCB DB flush mounting type, as per accepted practice, duly embedded and end plate completely flushed in wall, cable connection etc. complete.
102Supplying and installing of RCBOs (Residual current circuit breaker with overload and short circuit protection) ISI marked complete as per I.S. standard confirming to IEC: 61009-2-1 & IS:12640-2:2001, 240/ 415V 50 Hz with 10 kA short circuit withstand capacity for earth leakage, overload & short circuit protection including connection in existing enclosure in approved manner as per specification; 4 pole 25-32 Amps, 30 mA sensitivity
103Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of "C" series suitable for 240/ 415 Volts, 50 Cycle , 10 kA Value AC supply confirming to IS: 8828: 1996, IEC: 60898: 2002 but without enclosures; 6 Amp to 32 Amp Rating
104Fixing of MCB/ MCCB/ Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (Labour only); MCB / Isolator SP/DP
105Sub Lighting Distribution Boards: (Location - Indoor) Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of Bus bar, Neutral bar, Earth bar & two earth terminals etc. complete as per IS:13032 (exclusive of MCB & isolator); 4 way Double Door IP 43 protection
106Labour charges for fixing sheet steel enclosures, MCB DB flush mounting type, as per accepted practice, duly embedded and end plate completely flushed in wall, cable connection etc. complete.
107Supplying and installing of RCBOs (Residual current circuit breaker with overload and short circuit protection) ISI marked complete as per I.S. standard confirming to IEC:61009-2-1 & IS:12640-2:2001,240/415V 50 Hz with 10 kA short circuit withstand capacity for earth leakage, overload & short circuit protection including connection in existing enclosure in approved manner as per specification; 2 pole, 6-25 Amps, 30 mA sensitivity
108Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of "C" series suitable for 240/415 Volts, 50 Cycle , 10 kA Value AC supply confirming to IS: 8828: 1996, IEC: 60898: 2002 but without enclosures; 6 Amp to 32 Amp Rating
109Fixing of MCB/ MCCB/ Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (Labour only); MCB / Isolator SP/DP
110Point Wiring - Light/ Fan Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp, holders, ceiling roses etc) with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for Light/ Fan Points (using modular accessories); Short Point (up to 3 mtr.)
111Medium point (above 3 mtr up to 6 mtr.)
112Long point (above 6 mtr up to 10 mtr)
113Point Wiring- Light Plug Point Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp, holders, ceiling roses etc) with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for 3 Pin 6 Amp Socket outlet on separate box (using modular accessories); Short Point (up to 3 mtr)
114Medium point (above 3 mtr up to 6 mtr.)
115Long point (above 6 mtr up to 10 mtr)
116Point Wiring-Call Bell/ Buzzer Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp, holders, ceiling roses etc) with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for Call bell/ Buzzer Points (using modular accessories) Short Point (up to 3 mtr,)
117Medium point (above 3 mtr up to 6 mtr.)
118Long point (above 6 mtr up to 10 mtr)
119Point Wiring -Twin Control Light Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp, holders, ceiling roses etc) with 1.5 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in concealed rigid P.V.C. conduit (HMS) ISI Marked of suitable size and 1.5 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit etc. as required as per specification for Twin Control Light Points (using modular accessories); Short Point (up to 3 mtr.)
120Medium point (above 3 mtr up to 6 mtr.)
121Long point (above 6 mtr up to 10 mtr)
122Circuit/ Submain Wiring Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
1232 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1242 X 4 sq. mm + 1 X 4 sq. mm earth wire
1254 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
1264 X 4 sq. mm + 2 X 4 sq. mm earth wire
127Point Wiring- Light Power Point Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. Socket Outlet Point With 4 Sq. mm. PVC insulated cable FR with copper multi strand conductor ISI marked in Concealed rigid P.V.C Conduit (HMS) ISI Marked of suitable size etc. with 16 Amp. F.T. Switch & Socket/ S.S. Combined 6/16 Amp. of ISI Marked and 4 Sq. mm. PVC insulated copper earth continuity conductor of green colour inside conduit as per specification for same board switch socket 6/16A (using modular accessories);
128Modular Type Metal Box Supplying and fixing of approved make modular type metal box with modular frame/ base plate and cover plate including fixing in concealed / surface excluding switch, socket etc. as required for; 3 module
1294 module
1306 module
1318 module
132Modular Type PVC Box Supplying and fixing of approved make modular type P.V.C. box with modular base and cover plate including fixing on surface excluding switch, socket etc. as required for; 3 module
1334 module
1346 module
1358 module
136Call Bell/ Buzzer Supplying and fixing as per specification Call bell / buzzer of approved make with necessary materials complete.
137Modular Bell Push Switch Supplying and fixing as per specification 6 Amp 250 Volt Bell Push switch of approved make ISI marked with necessary material complete. 6/10 Amps S.P. 250 Volt Modular Switch Bell Push
138Electric Ceiling Fan Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, AC 230-250 volts including connections with all necessary material complete of approved as required confirming to IS :374/1979 with up to date amendments. Ceiling Fan (5 star & ISI)-1200 mm Sweep
139Ceiling rose Supply and fixing as per specification polycarbonate ceiling rose 3 plate of approved make ISI marked with necessary material complete.
140Modular Electronic Fan Regulator Supplying and fixing of approved make step type Modular electronic Fan regulator including connection etc. as required on existing board 100 Watt (2 module)
141Exhaust Fan (Heavy Duty) Supplying, erecting and testing of approved make Exhaust Fan heavy duty with mounting frame, blades AC 230-250 complete connection and including, frame bolt/ Anchor hole fasteners etc. complete finished of approved as required. 300mm sweep 900 RPM
142Exhaust Fan Louvers Supply and fixing of GI sheet 24 SWG Exhaust fan Louvers including grouting bolt, nut, & finishing etc on existing hole to complete the job as mentioned below: Sweep 300 mm
143Bulk Head Light P & F of IP65 IK10 rated LED bulk head type light fixture made from CRCA sheet steel housing suitable for mounting LED tube system (integral driver), Power consumption of 10-15W, 500-600 lumens system lumen efficiency 70 lm/ watt output suitable for 1 x 100 W GLS/ 9W CFL bulk head fixtures, life time of 50000 burning hours with 70% initial lumen maintained. CCT 3000°K, 4000°K and 6000°K. Fixture shall be in compliance with CE & KEMA standards. 9/10W Bulk Head LED
144Supplying, fixing and testing of approved make modular integral step / skirt LED light suitable for 3 module box and plate including fixing on wall as required, with necessary material complete
145External Lighting System: Street Lighting for Exterior Roads/ Parking Areas: Streel Light Poles - Providing and erecting hot dipped galvanized octagonal poles in single section made from 3 mm thick sheet having lockable weather proof flush door junction box complete erected in an approved manner on provided foundation. Suitable size & type of foundation bolts 4 nos. "J" type (EN8 grade) 5 mtrs. Height 130 x 70mm A/F, 200x200x12mm base plate, 4 nos x M16 x 450mm bolt with nut.
146GI Bracket- Providing and fixing of sword canopy type single arm GI bracket up to 2 Mtr. Long for 70mm A/F top octagonal pole
147GI Bracket- Providing and fixing of sword canopy type double arm GI bracket up to 2 Mtr. Long for 70mm A/F top octagonal pole
148GI Ring Carriage- Providing and fixing of ring carriage dia. not less than 750mm made of 50mm dia. GI pipe Light "A" class for 70mm A/F top octagonal pole with required clamps, nut, bolt etc as required. (for mounting LED flood Lights up to 4 nos)
149RCC Foundation (Octagonal Pole- 5m Ht.) - Designing and construction of footing foundation for octagonal pole of desired size including excavation in soil/soft rock, base concrete M-7.5 (1:4:8), 15mm thick and pedestal of RCC M-20 (1:1.5:3), required tar steel reinforcement for required size from base concrete, shuttering, curing etc. with existing foundation bolts complete as per specifications in an approved manner as per manufacturer drawing or engineer-in charge. (Foundation of size 45 x 45 x 100 cms. deep in below ground level with plinth of 45 cms x 45 cms (or 45 cms dia) x 20 cms above ground level suitable for 5 m height pole)
150High Mast Lighting System for Soprt Sites of Volley Ball/Lawn Tennis/ Basketball/ Kabbadi etc: Providing and erection on existing foundation 12.5 meter high mast lighting system suitable to install up to 8 nos x 150-400W LED flood light and control gear with integral power tool, weight 340 kg. comprising of 2 sections of hot dipped galvanized materials as per BSEN ISO 1461 thickness 3 mm, dia 100 mm & 360 mm for top and bottom respectively, stress fitting arrangement on site with 350 mm overlap dynamic loading to withstand max wind pressure as per -IS 875 part-III, parameters for structural & foundation design must be taken from wind tunnel test. Lightning protection of GI single spike 800 mm at top and at base inside compartment having double internal lock with adequate size of MCB erected on PVC board complete with base plate of 25mm thick 520 mm dia. and foundation bolts having 4 nos. bolts of 24mm dia 750 mm long (EN.8 grade) anchor plate 445 PCD, including accessories viz; (1) Lantern carriage of 50 NB ERW class-B, MS pipe covered with PVC sleeve suitable to carry 500kg. load and up to 8 fittings symmetrically. (2) Trailing copper cable 5x2.5 sq.mm, PVC insulated PVC Sheathed, (3) Double drum 350Kg Winch having gear 53:1, oil bath (SAE90/140) arrangement, (4) 2 nos. Stainless steel wire ropes 5 mm dia (7/19) breaking load capacity 1450 kg. x 2, (5) Integral power tool 3-phase, 0.75HP 2m/min single speed .torque limiter up to 500 kg adjustable, (6) Feeder pillar fabricated out of 14 SWG CRCA sheet and comprise of incoming MCB 32- 63 A TPN switch, HRC fuses, single dial timer, suitable size of contactors for lighting and power tool, 2 nos. outgoing, reversing switch for motor, (7) Foundation drawing, test certificate and guarantee certificate shall be provided by manufacturer. (without fixture and lamp)
151RCC Foundation(12.5 m High Mast Pole): Designing & casting of open raft shallow footing foundation with M20 cement concrete suitable for 12.5 meter high mast considering the safe soil bearing capacity at site as 10T/ sq.m at 2 meter depth including excavation, foundation, nut bolts in an approved manner drawing or engineer-in-charge.
152LED Flood Light for Volley Ball/ Lawn Tennis / Basket Ball. Kabaddi Area: P&F of SMD 350W LED Floodlight fixture with System efficacy of 110 lm/W (38500 lumens). Luminaire shall be made up of die cast Aluminium housing with PC lens and toughened glass diffuser. Luminaire shall be designed with street optic LENS for uniform light distribution. LM 80-08 compliant LEDs from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall be with IP66 protection. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 70. LED Driver shall be potted, Integrated type, Multistage, Isolated, APFC Constant Current-Constant Voltage operated driver with range 140-300V AC and Safety Extra Low Voltage < 60V DC as per IEC standard., Driver Efficiency > 85% & 4 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012. Similar to Wipro LF30-442-030-57-XX LED Flood Light/ Equivalent Make & Model.
153Power & Control Cables: 33/11kV Grade XLPE Insulated (AL) Cables Supply of approved high-tension-33kV grade XLPE insulated cable (conforming IS-7098/II/85) as per ISI standard 3 core armoured with alu.stranded conductor ISI marked as required of following sizes 150 sq.mm
1541100V Grade XLPE/ PVC Insulated (AL) Cables Supply of XLPE Insulated power cable (confirming IS-7098 Part-I) 1100 Volt grade, 1 core/ 2 core/ 3½ core/ 4 core ISI MARKED with Alu. Stranded conductor 3 CORE ARMOURED - 10 sq.mm
1553 CORE ARMOURED - 16 sq.mm
1563 CORE ARMOURED - 25 sq.mm
1573 CORE ARMOURED - 35 sq.mm
1583 CORE ARMOURED - 50 sq.mm
1591100V Grade XLPE/ PVC Insulated (AL) Cables Supply of XLPE Insulated power cable (confirming IS-7098 Part-I) 1100 Volt grade, 1 core/ 2 core/ 3½ core/ 4 core ISI MARKED with Alu. Stranded conductor 3½ CORE ARMOURED - 50 sq.mm
1603½ CORE ARMOURED - 120sq.mm
1613½ CORE ARMOURED - 240 sq.mm
1623½ CORE ARMOURED - 300 sq.mm
1631100V Grade XLPE/ PVC Insulated (AL) Cables Supply of XLPE Insulated power cable (confirming IS-7098 Part-I) 1100 Volt grade, 1 core / 2 core / 3½ core/ 4 core ISI MARKED with Alu. Stranded conductor 4 CORE ARMOURED - 16 Sq. mm
1644 CORE ARMOURED - 25 Sq. mm
1651100V Grade XLPE/ PVC Insulated Copper Cables: Supply of XLPE Insulated power cable (conforming IS7098) 1100 Volt grade/ Heavy duty power cable 2 core / 3 core ISI MARKED with copper stranded / solid conductor 2 CORE ARMOURED - 2.5 sq.mm
1663 CORE ARMOURED - 2.5 sq.mm
1674 CORE ARMOURED - 2.5 sq.mm
1681100V Grade XLPE/ PVC Insulated Copper Multicore Cables: Supply of XLPE/ PVC Insulated multicore control cable (conforming IS7098/ IS 1554), 650/ 1100 Volt grade ISI MARKED with copper stranded conductor of following size; 5 CORE ARMOURED - 1.5 sq.mm
1697 CORE ARMOURED - 1.5 sq.mm
17010 CORE ARMOURED - 1.5 sq.mm
17112 CORE ARMOURED - 1.5 sq.mm
1721100V Grade HRFR/ FRPVC Insulated Copper Cables: Supplying and fixing of multi core round HRFR/ FR PVC insulated copper (flexible) conductor & PVC sheathed cables 1100 Volts as per IS:694-1990 of approved make of following size. (30/ 0.25 mm) Three core 1.5 sq.mm. (for JB to Lighting fixtures)
173(50/ 0.25 mm) Three core 2.5 sq.mm. (for JB to lighting fixtures)
174(56/ 0.3 mm) Three core 4.0 sq.mm. (for AC/ lighting power circuit etc)
1751100V Grade PVC Insulated Copper Submersible Cables: Providing and laying ISI marked P.V.C. insulated submersible cable confirming to IS:694 with flexible copper conductor including making connection etc. as required 3c x 4 Sqmm PVC Submersible Cable (Cu)
1763c x 6 Sqmm PVC Submersible Cable (Cu)
177Cable End Terminations: HT Cable End Terminations- Providing & Making cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for 33 KV/11 KV 3 core XLPE alum.conductor cable as required as per specification and as per accepted standard including connection testing complete. Heat shrinkable Jointing kit 33 KV XLPE cable OUTDOOR termination
178120-185 sq. mm,
179Heat shrinkable Jointing kit 33 KV XLPE cable INDOOR termination
180120-185 sq. mm,
181LT Cable End Terminations- Supplying and making end termination with brass compression gland and aluminium lugs for following size of XLPE/ PVC insulated and PVC sheathed aluminium conductor cable as required. 3½ X 35 sq. mm (32mm)
1823½ X 50 sq. mm (35mm)
1833½ X 70 sq. mm (38mm)
1843½ X 120 sq. mm (45mm)
1853½ X 185 sq. mm (57mm)
186LT Cable End Terminations- Supplying and making end termination with brass compression gland and aluminium lugs for following size of XLPE/ PVC insulated and PVC sheathed aluminium conductor cable as required. 4 X 10 sq. mm (25mm)
1874 X 16 sq. mm (28mm)
188RCC Hume/ Metal/ HDPE Pipes for Cables: RCC Hume Pipe- Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 150 mm dia
189GI Pipe Sleeves- Supplying & installing G.I. Pipe for protection of underground cable fixed on wall/support/in trench/fixed between two rigid existing support of wall/beam for erection of ceiling Fan/down rod for stiff pendent for light luminaries/ fan/ protective for earthing, lightening conductor down strip/overhead service line/for submersible cable or centrifugal pump for water supply with necessary iron clamp coupler, bend, tee, elbow, nuts and bolts etc. complete in an approved manner as required to complete excluding cost of excavation/ dismantling & other finished masonry Item complete. 15 mm -"A" Class pipe ISI Marked (IS-1161-68)
19025 mm -"A" Class pipe ISI Marked (IS-1161-68)
19150 mm -"A" Class pipe ISI Marked (IS-1161-68)
192100 mm -"A" Class pipe ISI Marked (IS-1161-68)
193150 mm -"B" Class pipe ISI Marked (IS-1161-68)
194HDPE Pipes- Supplying and installing of double wall corrugated pipes (DWC) HDPE Pipe (IS 14930 Part II -marked ) for cable laid under ground with necessary material and at required depth up to 90cm. below road/ground surface, including excavation, back filling with excavated material, ramming and making the surface good. 63 mm outside dia.
19590 mm outside dia.
196Cable Trays & Accessories: Supply & laying GI ladder type cable trays with side channels of size - 75 x 15 x 15 mm/ 100 x 15 x 15 mm & rungs of size - 35 x15 x 15 mm spaced at 250 mm apart, fabricated from 2 mm thick sheet steel in standard length of 2.5 meter, duly hot dipped galvanized after fabrication as per IS 2629- 1989/ IS 4759-1984 including accessories such as coupler plates/ fish plates, bends, tees, reducers, elbows, covers and electro-galvanized hardware etc, erected on existing support as per specification and instruction of engineer in charge. 300(W) x 75(H) x 2.0 mm Thick
197450(W) x 75(H) x 2.0 mm Thick
198600(W) x 75(H) x 2.0 mm Thick
199Supply & laying GI perforated type cable trays with returned edge/ flange, fabricated from 2.0 mm thk sheet steel in the standard length of 2.5 mtrs, duly hot dipped galvanized after fabrication as per IS 2629-1989/ IS 4759-1984 including accessories such as coupler plates/ fish plates, bends,tees, reducers, elbows, covers and electro-galvanized hardware etc, erected on existing support as per specification and instruction of engineer in charge. 100(W) x 35(H) x 2.0 mm Thick
200150(W) x 35(H) x 2.0 mm Thick
201300(W) x 35(H) x 2.0 mm Thick
202Cable Laying: HT Cable Laying- in existing RCC Hume/ Metal Pipe Laying one number 3 core power cable of following size in the existing RCC/ Hume/ Metallic pipe as required. above 120 sqmm and up to 400 sq. mm.
203LT Cable (Single Run) Laying-directin ground Laying of one number XLPE/ PVC insulated and PVC sheathedpower cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Up to 35 sq. mm
204Above 35 sq. mm and up to 95 sq. mm
205Above 95 sq. mm and up to 185 sq. mm
206Above 185 sq. mm and up to 400 sq. mm
207LT Cable (Additional Run) Laying -directin ground Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Up to 35 sq. mm
208Above 35 sq. mm and up to 95 sq. mm
209Above 95 sq. mm and up to 185 sq. mm
210Above 185 sq. mm and up to 400 sq. mm
211LT Cable Laying- in existing RCC Hume/ Metal/ HDE Pipe Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Up to 35 sq. mm
212Above 35 sq. mm and up to 95 sq. mm
213Above 95 sq. mm and up to 185 sq. mm
214Above 185 sq. mm and up to 400 sq. mm
215LT Cable Laying- on existing Cable Trays Laying and fixing of one number XLPE/ PVC insulated and PVC sheathed power cable of 1.1 KV grade of following size on cable tray as required.Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Up to 35 sq. mm (clamped with 1mm thick saddle)
216Above 35 sq. mm and up to 95 sq. mm (clamped with 25x3mm MS flat clamp)
217Above 95 sq. mm and up to 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
218Above 185 sq. mm and up to 400 sq. mm (clamped with 40x3mm MS flat clamp)
219Excavation Work Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift up to 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. (for equipment foundation/ embeddingmetalic pipe sleeve/ Earth Wire/ Strips etc wherever required)
220Excavation for cable trenches of depth up to 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres.
221Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift up to 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.
222Steel Fabrication work: Supply, fabrication and erection of Angle/ Chanel/ Flat iron fitting for cable tray supports, over head line/ sub-station etc such as "D" bracket, cross arms, top clamp, "V" cross arms, Back/ Support clamps or other similar work etc. including nut bolts of required size, making holes, fabrication, welding, cutting, etc. and painting with one coat of red oxide paint & two coat of aluminium paint as required as per specification.
223Cable Route Marker - Supply & Fixing Cable Route Marker round / square size 100mm, 5mm. Thick, G.I. Plate duly bolted/welded on 35mm x 35mm x 5mm angle iron 60cm long including excavation, grouting in cement concrete 1:2:4 (1cement and 2 coarse sand :4 graded stone aggregate 20mm nominal size) foundation of size 20cm x 20cm x 30cm duly embedded in ground 30cm depth or as required.
224Earthing System: Earth Electrodes (for 33/ 11kV DP/ Trafo/ DG/ Motor/ SWGR) Pipe Earthing as per IS:3043 with perforated 3.0 Mtr. Long, 40 mm dia. " B " class G.I. Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size- 300mm x 300 mm and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance as required.
225Earth Electrodes (for Trafo/ DG Neutral) Plate Earthing as per IS:3043 with copper Earth plate of size 600mm x 600mm x 3.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. "B" class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size- 300mm x 300mm complete with alternate layers of salt and coke/ charcoal, testing of earth resistance as required.
226Earth Wire/ Strps S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection etc. as required. 8 SWG GI Wire (for LPBs, JBs & Lighting Pole etc)
22732mm x 6mm copper strip (for small rating trafo/ DG neutral)
22825x6 mm size GI earth strip (for small rating equipment/ cable tray
22932x6 mm size GI earth strip (For small rating equipment - Trafo/ DG, SWGRetc and for use as ground conductor)
23050x6 mm size GI earth strip (For higher rating equipment - Trafo/ DG, SWGRetc and for use as ground conductor)
231GI Pipe (Class A) S & Laying following size" A" class G.I. Pipe with accessories for laying earth conductor/strip in ground/surface/recess as required 15 mm dia.
23220 mm dia.
233Electrical & Fire Safety Equipment: Supplying & fixing of Fire Extinguisher/ Refills as per IS specification ABC type duly refilled 4 Kg & ready to use
234ABC type refill only 4 Kg
235Providing 4 buckets set with sand, self supported M.S.stand including shed duly painted with red colour as per IS.
236Rubber mat 2m x 1m, 1100V
237Hand Gloves 11KV Tested
238Fiber Discharge Rod includingConn copper Lead Tested
239Supply of First Aid Box complete with medicine & bandage as per specification. First Aid Box shall consists of standard makes- antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for medicinal user, Scissors, anti-septic solution (Savlon or similar) etc.
240Electric Shock Instruction Chart duly framed with glass, as reqd.
241Supplying and fixing as per specification Caution/ Danger Board as of approved make & design with necessary material complete. (Large Size)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy