| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 Sqm on plan, including dressing of sides and ramming of bottoms, lifts up to 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m: All kind of soil. |
| 2 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials:All kinds of soil |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinths, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited by ramming watering lead of 50m and lift up to 1.5m. |
| 4 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excava-ted soil as directed, within a lead of 50 m: All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. |
| 5 | Supplying and filling in plinth with Jamuna sand under floors, including watering,ramming, consolidating and dressing complete. |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering– All work up to plinth level -1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size). |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) |
| 8 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. |
| 9 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 10 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 11 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 12 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for:(A) Foundations, footings, bases of columns, etc. for mass concrete. |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for: (B) Suspended floors, roofs, landings, balconies and access platforms. |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for: (C) Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for: (D)Columns, Pillars, Piers, Abutments, Posts and Struts |
| 17 | Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. |
| 18 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand). |
| 19 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 20 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class desig-nation 7.5 in superstructure above plinth level up to floor V level-Cement mortar 1:4 (1 cement :4coarse sand). |
| 21 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding |
| 22 | Providing and fixing factory made door frame (single rebate) made out of single piece extruded solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 62 mm width & 32 mm thickness, frame will be mitred & Jointed with self driven self tapping screws of size 38 mm x 4 mm & PVC solvent cement, includingfixing the frame to wall with suitable dia & length anchor fastener as per manufacturer\"s specification and direction of Engineer-in-charge. |
| 23 | Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75 mm x 30 mm having wall thickness 5 mm. The styles, top & bottom rails shall have one side wall thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and railsshall be reinforced with M.S. tubes of size 33 mm x 17 mmx 1 mm, painted with primer , all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and the rails with a cavity, to receive single piece extruded 5mm PVC sheet as panel. The styles and rails will be mitred cut and joint with the help of PVC solvent cement & self driven self tapping screws.Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8 mm complete as per manufacturer\"s specifications and direction of Engineer-in-charge. 9.124.2 Decorative finish (both side wood grained finish) |
| 24 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete 250x16 mm |
| 25 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :200x10 mm |
| 26 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete 125mm |
| 27 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. 8.10.2 Granite Stone of approved shade |
| 28 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make,in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 29 | Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by themanufacturer) with water absorption less than0.08% and conforming to IS : 15622, of approved make, in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), includinggrouting the joints with white cement and matching pigments etc.,complete. Size of Tile 600x600 mm |
| 30 | Grading roof for water proofing treatment withCement mortar 1:3 (1 cement : 3 coarse sand) |
| 31 | 12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand) |
| 32 | 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6(1 cement: 6 fine sand) |
| 33 | 6 mm cement plaster of mix 1:3 (1 cement : 3 fine sand) |
| 34 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster |
| 35 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 36 | Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 37 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 38 | Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 39 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Wash basin size 550x400 mm with a single 15 mm C.P. brass pillar tap. |
| 40 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizesrespectively. |
| 41 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm |
| 42 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete:Semi rigid pipe, 40 mm dia. |
| 43 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 17.73.1 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 44 | Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2\" BSP thread and shapes, weighing not less than 60 gms. |
| 45 | Providing and fixing PTMT urinal cock of approved quality and colour. 17.76.1 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms |
| 46 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.18.8.1 15 mm nominal dia Pipes |
| 47 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.18.8.2 20 mm nominal dia Pipes |
| 48 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): 25 mm nominal bore. |
| 49 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work): 20 mm nominal bore |
| 50 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 51 | Providing and fixing PTMT bib cock of approved quality and colour: 15mm nominal bore, 86 mm long, weighing not less than 88 gms. |
| 52 | Providing and fixing PTMT stop cock of approved quality and colour: 15 mm nominal bore, 86 mm long, weighing not less than 88 gms. |
| 53 | Providing and fixing PTMT grating of approved quality and colour- Circular type: 100 mm nominal dia. |
| 54 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball: 20 mm nominal bore, 120 mm long, weighing not less than 198 gms. |
| 55 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour: 15 mm nominal bore with 45 cm length. |
| 56 | Making soak pit 2.5m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design: With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5 |
| 57 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. |
| 58 | Centering and shuttering including strutting, propping etc. and removalof form work for : Retaining walls, return walls, walls (any thickness) includingattached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. |
| 59 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.1 Group B |
| 60 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 2.1 20 mm Dia |
| 61 | Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3.1 3 x 2.5 sqmm |
| 62 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 63 | Supplying and fixing 6 way, Double door , single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 64 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25A |
| 65 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, SP miniature circuit breaker suitable for inductive load of single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 66 | Supplying 18-22 watt LED lumunar fixture complete with LED retrofit metallic lampbatten fixture powder coated box type body i/c marking of Text and number as required |
| 67 | Supplyingof 1200 mm sweep capacitor type A.C ceiling fan including fan regulator fixing at modular switch board complete with 30 cm down rod withhangingshackle , blade canopy suitable for 230/240 volt, 50 cycles/sec., single phase supply conforming to ISI |
| 68 | Supplying of Outdoor aesthetically designed 30 wattLED Street Light Luminare with single piece die cast aluminium housing, (including driver) with IP rating of IP66, complete with internal wiring, with extremely precision designed heat sink suitable for top open for easy maintenance, complete with IP66 protection Class, with polycarbonate cover .The fixture should be suitable for pole / bracket mounting. |
| 69 | Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of all type of street light fitting on pole / wall / structure including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. |
| 70 | Supplying and fixing out door type loop in loop out cable junction box (200 mm X 150 mm X100 mm)fabricated from 1.6 mm MS sheet enclosed wheather proof, dust proof, water proof and locking arrangement internally embedded gasket with bottom cable entry plat through cable glands. Seperate for incoming and out goingcables and wires duly fitted with following in it.HD Connector for 10 to 16 sqmm-4 Nos.6 amp SP \"C\" curve 10 KA MCB-1 No.fixing Clamps-2 Nos. |
| 71 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts “C” curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 72 | Supplying of 400mm sweep capacitor type A.C Wall fan complete with hangingshackle , blade canopy suitable for 230/240 volt, 50 cycles/sec., single phase supply conforming to ISI |
| 73 | Installation, testing and commissioning of pre-wired, all types lighting fittings, complete with all accessories and tube etc. directly on ceiling / wall / bracket, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing within fitting, within bracket & within loop box/point (Except conduit) etc. as required. |
| 74 | Wiring for circuit/ submain wiring alongwith earth wire with 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in GI Pipe as required. |
| 75 | Supplying of XLPE insulated and PVC tape innersheated aluminiumaluminium conductor armoured cable of 1.1 KV grade of following sizes confirming to IS:7098 (Part- I) 1988 with up to date ammendment as required. 17.1 2x10 sqmm |
| 76 | Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size up to 35 sqmm on wall / pole / steel structure surface as required. |
| 77 | Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size up to 35 sqmm in ground including excavaation, sand cushioning , protective covering and refiling the trench etc as required |
| 78 | Supplying and fixing of light class G.I. pipe of following size in mm dia. (nominal) 3 meter length along the pole for protection of under ground cable as required. 20.150 mm dia. (nominal). |
| 79 | Supplying and making end termination with brass compression gland and aluminium lugs for FOLLOWINGsizeof PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 21.12 X10 sq. mm (19mm) |
| 80 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 81 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 82 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 83 | Supplyof 300 mmexhaust fanfor 230 V,50Hz complete with all accessories like blade ,canopy, condenser ,regulator,internal wiring of the following makecat . confirming to ISI with up to date amendment etc |