Tender For Procurement Of Measuring Instruments For Electrical Department., barauni-Bihar

Hindustan Urvarak and Rasayan Limited has published Tender For Procurement Of Measuring Instruments For Electrical Department.. Submission Date for this Tender is 17-01-2023. Clamps Tenders in barauni Bihar. Bidders can get complete Tender details and download the document.




Tender Notice

35547829
Corrigendum : Tender For Procurement Of Measuring Instruments For Electrical Department.
Open Tender
Indian
Bihar
barauni
17-01-2023

Tender Details

Tender For Procurement Of Measuring Instruments For Electrical Department -Digital Multimeter , Hand Held, 100 Khz, True Rms Dc Voltage Range-1000 Volt, Accuracy-0.5%, Voltage Resolution-100Mvac Voltage Range-1000 Volt, Accuracy-0.5%, Voltage Resolution-100Mvdc Current Range-10 Ampère, Accuracy-1.5%, Current Resolution- 100Maac Current Range-10 Ampère, Accuracy-1.5%, Current Resolution- 100Ma Resistance Range-40 Megaohm, Accuracy-1%, Resolution-10 Ohm, Display Digit- 3.5, Counts -4000, Safety Certification-Csacapacitance Range ( Micro Farad ) -.01 To 1000, Frequency Range ( Khz ) - 50, Safety Rating, Category Iii 600 V Of Iec 61010. Power Requirements Battery Operated, If Battery Operated, Then Type Of Battery-Non Rechargeable ( Alkaline ) , If Rechargeable , Then Chemistry Of The Battery Lithium Ion, If Non-Rechargeable , Then Size Of The Battery / Cell-Aa, Voltage Of Rechargeable Battery-9 Voltcapacity Of Rechargeable Battery ( Milli Ampere Hour ) -2800 2 Megger , 500V-1000V Type :Hand Held, Measurement Range : 0.01 M Ohm To 10 Gohm, Measurement Accuracy :2 % Measurement Resolution :0.01 Megaohm, Test Voltage : 500- 1000 Volt, Test Current : 1 Milliampèresafety Rating :Category Iii 600 V Ofiec 61010, Warranty :1 Year, Ac / Dc Voltagemeasurement ( Volt ) -600, Live Circuit Detection, Inhibit Test Terminal Voltage >30 V Prior To Initialization Of Test, Auto Discharge Time ( Second ) - Less Than 0.5, Power Requirements-Battery Operated 3 Megger , 500V-5000V Type :Hand Held, Kew3125a , Measurement Range : 0.01 M Ohm To 10 Gohm, Measurement Accuracy :2 % Measurement Resolution :0.01 Megaohm, Test Voltage : 5000 Volt, Test Current : 1 Milliampèresafety Rating :Category Iii 1000 V Of Iec 61010, Warranty :1 Year, Ac / Dc Voltagemeasurement ( Volt ) -600, Live Circuit Detection, Inhibit Test Terminal Voltage >30 V Prior To Initialization Of Test, Auto Discharge Time ( Second ) - Less Than 0.5, Power Requirements-Battery Operated 4 Fluke 4 Digit Backlit Lcd Hand Held True Rms Clamp Meter , ( 0 To 400A ) Ac / Dc, Resistance Measurementrange: 10 Kiloohm, Resistance Measurementaccuracy ( + / - ) : 0.5 Percentfrequency Measurementrange-0.5 Kilohertz, Measurement Type-True Rms, Count-10000, Ac Currentmeasurement Accuracy ( + / - ) -1.5 Percentac Voltage Measurementrange-1000 Volt, Ac Voltage Measurementaccuracy ( + / - ) -1 Percent Dc Currentmeasurement Range-1000 Ampère, Dc Currentmeasurement Accuracy ( + / - ) -1.5 Percentdc Voltage Measurementrange-1000 Volt, Dc Voltage Measurementaccuracy ( + / - ) -1 %, Clampmeterwithiflex, Power Requirements- Battery Operated, Safety Certifi Cation-Ce, Safety Rating-Cat Iv 300 V Of Iec 61010 -2-D31, Details Of The Standardaccessories Suppliedwith The Equipment-Battery, Test Lead 5 Leakage Tester Ac & Dc ( 0-5 ) A , Ac / Dc, Type Of Product : Digital Leakage Currenttester, Weight :220G, Size :169X75x40mm, Model No. : Kew 2434Repaire Warranty Inmonth :12 Months, 6 Digital Tester , Mdtn-82, 130 Mm Length

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Jan-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-01-2023
2 14-Jan-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-01-2023

Key Value

Document Fees
Refer document
EMD
INR 20195.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Measuring Instruments for Electrical Department.
Sl. No. Item Description
1Digital Multimeter , hand held, 100 KHZ, True RMS DC Voltage Range-1000 Volt, Accuracy-0.5%, Voltage resolution-100mV AC Voltage Range-1000 Volt, Accuracy-0.5%, Voltage resolution-100mV DC Current Range-10 Ampère, Accuracy-1.5%, current resolution- 100mA AC Current Range-10 Ampère, Accuracy-1.5%, current resolution- 100mA Resistance Range-40 megaOhm, accuracy-1%, resolution-10 Ohm, Display digit- 3.5,counts -4000,safety certification-CSA Capacitance Range ( Micro farad )-.01 to 1000,Frequency Range ( KHz )- 50, Safety Rating,Category III 600 V of IEC 61010. Power Requirements Battery Operated,if Battery Operated, then Type of Battery-Non Rechargeable (Alkaline),if rechargeable , then chemistry of the battery lithium ion,if Non-rechargeable , then size of the battery / cell-AA, Voltage of rechargeable Battery-9 Volt capacity of rechargeable battery(milli Ampere Hour)-2800
2Megger ,500V-1000V Type :Hand Held, Measurement Range : 0.01 M Ohm to 10 GOhm,Measurement Accuracy :2 % Measurement Resolution :0.01 megaOhm,Test Voltage : 500- 1000 Volt,Test Current : 1 milliAmpère Safety rating :Category III 600 V ofIEC 61010,Warranty :1 year,AC/DC VoltageMeasurement (Volt)-600, Live Circuit Detection,inhibit test terminal voltage >30 V prior to initialization of test,Auto Discharge Time(Second)- Less than 0.5,Power Requirements-Battery Operated
3Megger ,500V-5000V Type :Hand Held, KEW3125A ,Measurement Range : 0.01 M Ohm to 10 GOhm,Measurement Accuracy :2 % Measurement Resolution :0.01 megaOhm,Test Voltage : 5000 Volt,Test Current : 1 milliAmpère Safety rating :Category III 1000 V of IEC 61010,Warranty :1 year,AC/DC VoltageMeasurement (Volt)-600, Live Circuit Detection,inhibit test terminal voltage >30 V prior to initialization of test,Auto Discharge Time(Second)- Less than 0.5,Power Requirements-Battery Operated
4Fluke 4 digit backlit LCD Hand held true RMS Clamp meter ,(0 to 400A) AC/DC, Resistance MeasurementRange: 10 kiloOhm,Resistance MeasurementAccuracy (+/-): 0.5 percent Frequency MeasurementRange-0.5 kiloHertz, Measurement Type-True RMS,count-10000, AC CurrentMeasurement Accuracy(+/-)-1.5 percent AC Voltage MeasurementRange-1000 Volt,AC Voltage MeasurementAccuracy (+/-)-1 percent DC CurrentMeasurement Range -1000 Ampère,DC CurrentMeasurement Accuracy(+/-)-1.5 percent DC Voltage MeasurementRange-1000 Volt,DC Voltage MeasurementAccuracy (+/-)-1 %, ClampmeterwithiFlex,Power Requirements- Battery Operated,Safety Certifi cation-CE,Safety Rating-CAT IV 300 V of IEC 61010 -2-D31,Details of the StandardAccessories Suppliedwith the Equipment-Battery, Test Lead
5Leakage tester AC & DC (0-5) A , AC/DC,Type of Product : Digital Leakage CurrentTester,Weight :220g,Size :169x75x40mm,Model No. : KEW 2434 Repaire Warranty InMonth :12 Months,
6Digital tester , MDTN-82, 130 mm length
Disclaimer :