General-Vadakkumbadu Ghss-Construction Of Stage, Second Floor To Existing Building & Development Of Infrastructure Facilities For Ghss Vadakkumbadu -Composite Work-1, Kannur-Kerala

Public Works Department-PWD has published General-Vadakkumbadu Ghss-Construction Of Stage, Second Floor To Existing Building & Development Of Infrastructure Facilities For Ghss Vadakkumbadu -Composite Work-1. Submission Date for this Tender is 09-01-2023. Building Work Tenders in Kannur Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

35530420
General-Vadakkumbadu Ghss-Construction Of Stage, Second Floor To Existing Building & Development Of Infrastructure Facilities For Ghss Vadakkumbadu -Composite Work-1
Open Tender
Indian
Kerala
Kannur
09-01-2023

Tender Details

General-Vadakkumbadu Ghss-Construction Of Stage, Second Floor To Existing Building & Development Of Infrastructure Facilities For Ghss Vadakkumbadu -Composite Work-1

Key Value

Document Fees
INR 9759 /-
EMD
INR 100000.0 /-
Tender Value
INR 2.80 Crore /-

BOQ Items

Work Name:GENERAL-Vadakkumbadu GHSS-Construction of Stage, Second floor to Existing Building & Develepment of Infrastructure Facilities For GHSS Vadakkumbadu -Composite Work-1
Sl. No. Item Description
1Appendix - A - Construction of Building(Civil work)
22.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
315.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
415.9.2:Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In cement mortar
52.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
64.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
72.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
850.2.25.1:Filling with contractor"s own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
97.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
10OD59553/2022-2023:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for RCC work using cement content as per approved design mix, includingpumping of concreteto site of laying but excluding the cost of centering shuttring, finishing and reinforcement including admixture in recommended properties as per IS:8103 to accelarate retard setting of concrete ,improve workability without impairing strength and durability asper direction of engineer -in charge. cement content considered for this work is 340kg/cm3 of concrete .excess /less cement as per mix design is not payable /recoverable. detailed mix design to be supplemented .All work up to plinth level
11OD59554/2022-2023:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for RCC work using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering shuttring, finishing and reinforcement including admixture in recommended properties as per IS:9103 to accelarate retard setting of concrete ,improve workability without impairing strength and durability as per direction of engineer -in charge. cement content considered for this work is 340kg/cm3 of concrete .excess /less cement as per mix design is not payable /recoverable. detailed mix design to be supplemented .All work above plinth level upto floor 5 level
12OD59555/2022-2023:Laterate masonry with neatly dressed laterate stone of size 35x20x20cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.
13OD59556/2022-2023:Laterate masonry with neatly dressed laterate stone of size 35X20X20 cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc.
14OD59557/2022-2023:Laterate masonry with neatly dressed laterate stone of size 35x20x20 cm or nearest size in cement mortar 1:6 for superstructure above floor two level up to floor five level including all cost of materials and labour charges etc.
1550.6.6.2:Hollow block masonry using pre cast solid blocks (factory made) of size 40x20x10cm or nearest available size confirming to IS 2185 part I of 1979 for Super structure up to floor two level for 10 cm thick wall in: CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding etc complete
1650.6.6.3:Hollow block masonry using pre cast solid blocks ( Factory made ) of size 40x20x10cm or nearest available size confirming to IS 2185 part I of 1979 for Super structure above floor two level upto floor five level for 10cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand ) including cost of scaffolding etc complete
175.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
185.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
195.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
205.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
215.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
225.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
235.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
245.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
25OD59558/2022-2023:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Irul wood
26OD59559/2022-2023:Providing and fixing paneled or paneled and glazed shutters for doors, windows and clerestory windows, 30 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding paneling which will be paid for separately, all complete as per direction 0f Engineer in- charge. using Irul wood
27OD59560/2022-2023:Providing and fixing paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clerestory windows(Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) paneling for paneled or paneled and glazed shutters 25 mm to 40 mm thick using good quality Irul wood
2821.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
2921.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
3021.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
319.53:Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
329.97.4:150x10 mm
3350.9.15.1:Supplying and fixing 200 mm Aluminium aldrop
34OD59561/2022-2023:65mm pad lock
359.66.2:Providing and fixing ISI marked oxidised M.S. handles conforming to IS : 4992 with necessary screws etc. complete:100 mm
369.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
3710.26.3:Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes
389.119:Providing and fixing factory made P.V.C. door frame of size 50x47 mm with a wall thickness of 5 mm, made out of extruded 5 mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos. of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door fame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer"s specification and direction of Engineer-in Charge.
399.120.1:Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and sized of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture.M.S. frame covered with 5 mm thick heat moulded PVC "C" channel of size 30 mm thickness, 70 mm width out of whicj 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5mm thick, 95 mm wide PVC sheet out of which75 mm shall be tapered in 45 degree on th inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flatand 20 mm shall be tapered on both sides to form lock rail.Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mmx2) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded /sealed to the styles & rails with 7 mm (5 mm + 2 mm ) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the "C" Channel using PVC solvent adhesive etc.complete as per direction of Engineer -in-charge, manufacture"s specification & drawing.30 mm thick plain PVC door shutters
4013.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
4113.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
4250.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
4311.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
4411.46.2:Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, ofapproved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
4511.38:Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of Ist quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 ( 1 cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete.
4611.36:Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
47OD59562/2022-2023:Providing and laying Mat finishvitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
4813.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
4913.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
5013.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
5113.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
5213.62.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to givean even shade:Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture .
5317.1.1:Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
5417.2.2:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked black solid plastic seat and lid
5550.17.1.4:Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge.
5617.4.1:Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:One urinal basin with 5 litre white P.V.C. automatic flushing cistern
5717.7.4:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
58OD59563/2022-2023:Providing and fixing 15mm press type CP tap
5950.18.7.2.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge 20 mm dia 10 Kgf/cm2- Internal work - Exposed on wall
6050.18.7.3.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall
6150.18.7.4.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall
6250.18.7.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall
6350.18.8.9.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC Solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 110 mm pipe 4 kgf/cm2
6450.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend
6550.18.9.9.2:Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2
6618.48:Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
67Appendix - B - Rain water harvesting(Civil work)
682.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
692.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
704.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
715.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
725.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
735.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
745.23:Smooth finishing of the exposed surface of RCC work with 6mm thick cement mortar 1:3 ( cement : 3 fine sand).
75OD59551/2022-2023:Laterate masonry with neatly dressed laterate stone of size 35x20x20cm or nearest size in cement mortar 1:6 for foundation and basement including all cost of materials, labour charges etc.
7650.18.9.7.1:Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge. 63 mm dia 6Kgf/cm2
7750.18.9.9.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
7850.18.9.10.1:Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2
7950.18.9.20.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend
80Appendix - C - Septic tank(Civil work)
812.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil
824.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
835.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
845.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
855.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
865.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
87OD59552/2022-2023:Laterite masonry with neatly dressed laterite stone of size 35x20x20cm or nearest size inCM for foundation & basement including all cost of material labour charges etc
8813.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
89Appendix - D - Ground work(Civil work)
902.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared
912.1.1:Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil
92OD59539/2022-2023:Collection of good quality red earth from the excavated by sieving and stacking. including Cost of all labour charge etc complete
93OD59540/2022-2023:Filling with available excavated earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, rolling and watering rolling every 3rd and top-most layer with power roller of minimum 8 tonnes lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.
94OD59541/2022-2023:Supplying and stacking good quality sieved red earth at site for measurment . cost including all labour and transportation charges etc.
95OD59542/2022-2023:Supplying and stacking good quality river sand of 1st quality at site cost including all labour and transportation charges etc.
96OD59543/2022-2023:Mixing the sieved red earth and sand in the ratio 80:20 and spreading layer by layer cost including all labour charges
97OD59544/2022-2023: Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc.and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.
9815.9.1:Demolishing stone rubble masonry manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer -in- Charges:In Lime Mortar
992.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
1004.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
101OD59545/2022-2023:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for RCC work using cement content as per approved design mix, includingpumping of concreteto site of laying but excluding the cost of centering shuttring, finishing and reinforcement including admixture in recommended properties as per IS:8103 to accelarate retard setting of concrete ,improve workability without impairing strength and durability asper direction of engineer -in charge. cement content considered for this work is 340kg/cm3 of concrete .excess /less cement as per mix design is not payable /recoverable. detailed mix design to be supplemented .All work up to plinth level
102OD59546/2022-2023:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is notpayable or recoverable separately.All work above plinth level upto floor V level
1035.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
1045.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
1055.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
1065.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
1075.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
1082.25:Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
109OD59547/2022-2023:Laterite masonry with neatly dressed laterite stone of size 35x20x20cm or nearest size inCM for foundation & basement including all cost of material labour charges etc
110OD59548/2022-2023:Lateritemasonry with neatly dressed laterite stone of size 35x20x20cm or nearest size in CM 1:6 for SS above plinth level up to floor two level including all cost of materials and labour charges etc.
11113.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
11213.48.1:Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
113OD59549/2022-2023:Providing and laying Mat finishvitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
114OD59550/2022-2023:Supplying and fixing sports net (30mm sq nylon woven fish net with 2 mm thick nylon wire) for covering the existing fencing structure including all charges.
1159.48.2:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
11613.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
117ELETRIFICATION(Electrical work)
1181.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1191.55.3:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
120OD206070/2022-2023:Wiring combined plug point together with the light point/ fan point/ exhaust fan point/ call bell point including 6 A 5 pin modular socket controlled by 6A one way modular switch in the existing switch board and giving connection to the phase,neutral and earth terminal with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable ( Green wire for earthing) etc as required.
1211.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
12290.3.22.3:Supply & installation of light fittings on flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made of CRCA sheet of .5mm thickness complete with all accessories andlamps etc. directly on wall using 2 nos. flat iron brackets made from 25x6mm flat iron, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture
12390.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thicknesscomplete with all accessories andlamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
1241.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
125OD92342/2022-2023:Supplying and fixing 9W LED bulb.as reqierd
126OD92399/2022-2023:Supply, Conveyance and fixing 300x300mm Square recess mounting down light fittings out putnot less than 1800 lumen , efficacy not less than 100 lumen /Watt pf greater than 0.95,in the existing opening of false ceiling, giving connections with the existing wire etc., as required.
127OD78574/2022-2023:Supply Conveyance, installation testing and commissioning of surface mounting Bay light fittings of 100W efficacy of 150 lumen/W of all types directly on ceiling including giving connections with required length 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring ,making good the damages , color washing etc. as required. ( philips- BY 515P LED 100S 5700NB PSU GR or equivalent)
12890.15.4.6:Supply Conveyance, installation, testing and commissioning of 70W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)
12990.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
13090.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
13190.4.2:Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.
1321.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
133OD92718/2022-2023:Supplying and providing extra H.G conduit down rod of 19 mm dia 1.00 m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant ISS or with the extended original wiring and giving connection etc. as required.
134OD92720/2022-2023:SITC of 300/305 mm sweep Light duty exhaust fan in metal frame
13590.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
136OD92725/2022-2023:Supply, conveyance, installation, testing and commissioning of 450mm metal blade sweep Havells make High speed wall fan suitable for 230 V A.C supply including necessary clamps, etc giving connection as required (V3 Silver black/equivalent)
1371.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1381.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
1391.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1401.27.3:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
1411.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
14290.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
14390.10.1.6:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface
1441.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1451.28.1:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
1461.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
1471.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
14890.10.3.14:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator
1491.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1501.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
15190.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
15290.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator
1531.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1541.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1551.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1561.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1571.17.9:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.9 x 1.5 sq. mm
1581.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1591.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1601.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm
1611.17.15:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
1621.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
16390.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
16490.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
16590.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
16690.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
16790.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
16890.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
169OD78572/2022-2023:Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required. 12x3mm brass nut and boltetc. as required. 12 x 3 mm brass bolt & nut
1702.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
1712.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door
17290.11.1.12:Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)
1732.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1742.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
1752.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1762.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1772.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
17890.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid
17990.9.2.4:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.Flat angle 90 degree
18090.9.2.3:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree
18190.9.2.5:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.Internal angle 90 degree
18290.9.2.11:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.Cable retainer
18390.9.2.14:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.8 module mounting box
18490.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.End cap
18590.9.2.10:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recessincluding cutting the wall and making good the damages in case of recessed installation as required.Joint cover
18690.12.7.29:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
1879.1.22:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
18890.12.7.30:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm
1899.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
190OD176458/2022-2023:Supply conveyance installation testing and commissioning of 5KVAUPS as per technical details given below. The UPS enclosure shall be fabricated from 1.6mm or nearest suitable size CRCA sheet and free from defects, sharp edges, nicks, scratches, burns etc. Provision for required ventilation, easy maintenance, . The supplier should submit tested documents, operation manual, service manual etc while the UPS is supplied. The supplier should provide three year guarantee with regular periodical servicing.Capacity-5 KVA, (floor mounting / Rack type),DC Working Voltage -48 V DC, Input -Single phase 100-285V,Output-Single phase 220V (with +/- 2% voltage regulation) 50Hz (with +/- 1% frequency regulation), Output wave form -Pure sine wave, Switching-Switching device shall be IGBT's or equivalent, Switching frequency-Switching frequency shall be minimum 10 kHz,True power-True power should be minimum 70% of active power, Harmonic distortionAllowed total harmonic distortion at out put is maximum 3% on resisitive load at the time of input harmonics less than 10%,Efficiency-Overall efficiency minimum 90% at rated out put voltage and frequency, Power factor-Power factor at rated load should be >0.9, Bypass facility-Bypass system should be provided in UPS to maintain emergency at the time of maintenance, Protection-a. Over load. Over volatge, Short circuited. Under voltage for battery terminal, LED- a. Main on. Output on. Battery charging and discharging. Output over load, LCD/LED Display-a. Input volatge. Out put voltage, Battery voltage, kVA/kW, e. Load %, h. Battery charge %.. .. ( Luminous/Delta/ Numeric/Equivalent) and 4 nos 12V 150 AH Fully charged Lead acid Tubular battery ( Luminous/ Exide/Amron/Equivalent) etc complete
191OD176459/2022-2023:SITC of Inverter type wall mounting split air conditioner unit of the following ratings conforming to relevant IS suitable for operating on 230V, 50Hz single phase AC supply, filled with R-410 A /R32 refrigerant gas, high energy efficient, RoHS complaint, capable of performing functions like cooling,dehumidifying, air circulating, filtering etc with copper condensor coilincluding refrigerant copper piping 3m with insulation,control cable up to 5m, 3 m drain pipe, company fabricated metal stand for installing out door unit, microprocessor control with cordless remote control,etc. and one year 4 Nos free service. 2Tr single phase 5 Star rated inverter type Split Ac unit( Carrier, Daikin, , Blue star, Hittacchi ,) .
192OD176460/2022-2023: Supply and fixing5 KVA voltage stabilizer V guard or equivalent with input voltage 170 to 270 V and output voltage range of 210 to 230 V with overload protection (cutt off) time delay, indicators,and chord wire etc.as required.( V guard VG400/equivalent)
19390.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
19490.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
19590.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
19690.14.7:Supply and providing copper earth bus in the panel board
19790.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
198OD204729/2022-2023:Supply and fixing 2A, HRC Fusewith HRC Fuse link with connections, in existing meter board
199OD204730/2022-2023:Supply and providing Blue colour LED indicators, AC/DC 22.5mm cut out dia
200OD205955/2022-2023:Supply and fixing digital Multifunction meter to read: V, A, F, 3 phase accuracy class 1
201OD205956/2022-2023:Supply and fixing 125/5 A, 5 VA, accuracy class 1, Tape wound Metering CT giving connection as required
202OD204731/2022-2023:Supply and providing Red, Green, Black, Yellow, Orange colours LED indicators, AC/DC 22.5mm cut out dia
20390.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
2042.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
2052.1.3:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 Amp TP&N
2062.1.4:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.125 Amp TP & N
207OD205943/2022-2023:Providing and fixing 32A TPN isolator inside the existing pannel board with ISI marked including drilling holes, making connection etc as required
208Providing Flood light at ground(Electrical work)
20914.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
21014.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
21114.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
21214.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
213OD206288/2022-2023:Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete .Thermo-Mechanically Treated bars of grade Fe-500D or more.
214OD139833/2022-2023:Supply installation testing and commissioning ofOctogaonal Pole made single sections of hot dip galvanised GI sheet 70mm top diameter, 175mm bottom diameter, 3mm sheet thickness, base plate dimensions of 275 x 275x 16 mm suitable for wind speed as per IS 875 Part III including hot dip galvanised GIsuitable bracket arrangement for mounting 6/8luminaries in 2 rows as per requirement with nuts ,bolts etc for fixing lightsalong with junction box ,4 Way Bakelite connector provision for fixing DP MCB,and lighting spikesincluding ladder/climbing arrangements with hot dip galvanised GI rod and connector foundation bolt 4 nos fixing in existing RCC foundation and junction box ,etc, complete 10 Meters
215OD176398/2022-2023:Supply Conveyance, installation, testing and commissioning of 250W LED flood light output greater than 110lumen/watt Matt black textured powder coated pressure die cast aluminum LED housing designed to act as heat sink for efficient dissipation of heat. White powder coated aluminium reflector. LEDs are provided with secondary lens optics to get optimum optical performance. The drivers used are specially designed to have built-in surge voltage, open/short circuit protections. Internal surge of 4Kv and External surge protection of 10 KV provided for additional safety. Luminaire should have CCT of 5700, CRI >70, IP 66 protection, IK 08, PF>.95, THD< 10% power factor>0.98.(LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer)( Bajaj PRAZE F 300L WH NB-A5 TG SD/Philips/Wipro/Crompton)
2161.21.4:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm
21790.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
21890.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLSPVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
2192.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
22090.12.5.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm
22190.12.5.39:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 6 sq mm
22290.12.5.41:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 16 sq mm
2239.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
2249.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
2259.1.33:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
22690.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
22790.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
22890.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
2292.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
230OD206381/2022-2023:Supplying and fixing Four pole sheet steel enclosure on surface/ recess, complete with din bar powder painted etc. as required.
2312.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
232SITC OF FIRE FIGHTING SYSTEMS(Electrical work)
23390.17.4.1:Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) a. Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. c. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 900 lpm at 35 m Head
23490.14.1.1:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br> Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame)
23590.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
23690.14.28.3:S & F Motor starters of the following ratingsThree phase DOL starters for 10HP motor
23790.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
2382.1.1:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N
239OD204538/2022-2023:Supply and fixing 2A, HRC Fusewith HRC Fuse link with connections, in existing meter board
240OD204539/2022-2023:Supply and providing Blue colour LED indicators, AC/DC 22.5mm cut out dia
241OD204540/2022-2023:Supply and providing Red, Green, Black, Yellow, Orange colours LED indicators, AC/DC 22.5mm cut out dia
24290.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
24390.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
24490.12.7.13:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3 core 6 sq mm with factory made clamp
2451.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
2461.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
24790.17.7.6:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia
24890.17.7.1:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia
24990.17.7.7:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia
25090.17.11.5:Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia
25190.17.14.5:Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia
25290.17.17.1:Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. a. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 b. 20 mm nominal internal dia gun metal globe valve & nozzle. c. Drum and brackets for fixing the equipmets on wall. d. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m
25390.17.19.1:Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe
254OD205655/2022-2023:Supply, conveyance and fixing Emergency Fire escape LED light fitting with 2 nos LED lamps, 7 AH SMF battery Charging unit Exit sign display etc complete in MS enclousure as required.
255OD205723/2022-2023:Supply, installation, testing and commissioning of Gun metal Air Release valve 20mm dia as required
256OD205761/2022-2023:Supply & fixing of pressure Gauge in M.S. pipe line as required
257OD205656/2022-2023:Supplying , fixing, testing and commissioning of 25mm dia Cast iron half turn Ball Valve ISI marked complete as required.
258OD205653/2022-2023:Supply and Installation of ABC stored pressure type 6 Kg capacity Fire Extinguisher with pressure indicationcomplete conforming to IS 15683 with initial charging and Installation bracketsetc as required
25990.17.22:Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required
260OD204558/2022-2023:Supply & erection ofGlow Sign board 3mm thick PVC foam board Assembly Point sign board16" x 16"
261OD204559/2022-2023:Supply & erection of Fire Escape rout in each floor having size 12" x 16"made of 3mm thisk acrylic sheet with glass frame
262OD204560/2022-2023:Supply & erectionof Glow Sign Boardmade of 3mm thick PVC foam boardfor each floor 12" x 4" (Fire Lift, Passenger Lift, Electrical Duct, Fire Station, Main Stair, Fire Exit, Floor Display, & Pump Room
263OD205718/2022-2023:Charges for Preparation of electrical /fire drawings in A3 sheet as per requirements for submitting electrical inspectorate/ fire department for approvals-First copy
264OD205719/2022-2023:Charges for Preparation of electrical /fire drawings in A3 sheet as per requirements for submitting electrical inspectorate/ fire department for approvals- Additional copy
265Installation of PA Announcement System (Electronics Work)
266OD149042/2022-2023:Supply and installation of100+100Watt Two zone PA Amplifier having 6 Mic inputs and 2 Aux inputs, 50-15,000Hz frequency response,Bass/Treable/ Volume controles, 4ohm,8ohm , 70V and100V outputs and MP3 Player with USB, SD&MMC card reader and Remote Control (Model: AHUJATZA2000DP or equivalent)
267OD149043/2022-2023:Supply and installation of 8 W PA Wall/Ceiling speaker with 60-15,000Hz Frequency response and power taps of 8/4/2W (Model Ahuja BS-6082T or equivalent)
268OD149044/2022-2023:Supply and installing 30 W PA Bi-directional speaker with 120-15,000Hz Frequency response and power taps of30/20/10/5W on 100V. (Prefered Model Ahuja SP-6305TD or equivalent)
269OD149045/2022-2023:Supply and installation of good quality Speaker Volume Controller (Model: AHUJA AT-40 or equivalent)
270OD149046/2022-2023:Supply of Professional PA microphone having frequency response 50 Hz to 16,000 Hz, Impedance 300 ohm, sensitivity 2.mV/Pa, with professional type XLR connector and 10 Meters shielded Mic. Cable. (Model: AHUJA ASM580XLR or equivalent)
271OD149047/2022-2023:Supply of Single zone desktop Paging Microphone fitted with flexible 300mm gooseneck and a high quality unidirection dynamic cartridge supplied with 6 m twin core shielded low noise cable. (Model: AHUJA ACM-96CH or equivalent)
272OD149048/2022-2023:Supply and fixing of 20 mm rigid PVC conduit (white/ ivory) with IS 9537 / 1983 Part III – conforming to ISI standard with all accessories.
273OD149053/2022-2023:Supply and laying of ISI standard 2 x 1.5 mm Oxygen free Speaker cable through the existing conduit
274OD149052/2022-2023:Supply of good quality Multi Wood Rack having minimum 700mm width and 600mm depth, and having 1 no. of partitions of 300 mm hight, supplied with AC Power Distibution Box having minimum 6 Nos. of ISI standard 3 pin plug points and 3m cable length.
275Installation of PA System in the Auditorium(Electronics Work)
276OD149055/2022-2023:Supply and installation of675+675 Watt Dual Channel Direct coupled PA Power Amplifier having Mono/Stereo/Line inputs, 20-20,000Hz frequency response, 2x XLR and Stereo Phone jack inputs, Speakon 4 way and heavy duty Binding post for each channel (Model: AHUJA LXA-1400 or equivalent)
277OD149056/2022-2023:Supply and installation of 8 Channel Audio Mixer with 8 Mic/Line inputs, 3 Band EQ per channel, Stereo RCA input with control, Headphone output with level control, 1 Aux send, L/R pan pot and clip LED per channel, Delay EFX on board & FX send per channel,Balanced XLR & ¼” Jack Master Output and USB MP3 Player supplied with a remote. (Prefered model: Studiomaster AiR 8U or equivalent)
278OD149058/2022-2023:Supply of200 W PA Cabinet Wall speaker with 10" LF Speaker, 65-18,000Hz Frequency response and 8 impedance, and installation on the wall using suitable Wall mounting kit. (Model: Ahuja VX-200 and Ahuja AWB-30 or equivalent)
279OD149062/2022-2023:Supply and installation of 160W (RMS) Active Monitor Speaker with XLR and Phone inputs and having 65 - 18,000Hz Frequency response. (Prefered Model: Studiomaster B200 or equivalent)
280OD149063/2022-2023:Supply of good quality Tripod PA Speaker standhaving 2.5feet to 3.5 feet height adjustment and 25Kg load capacity
281OD149064/2022-2023:Supply of Professional PA microphone having frequency response 50 Hz to 16,000 Hz, Impedance 300 ohm, sensitivity 2.mV/Pa, with professional type XLR connector and 10 Meters shielded Mic. Cable. (Model: AHUJA ASM580XLR or equivalent)
282OD149065/2022-2023:Supply of PA UHF Dual channel Wireless Microphone having Balanced XLR output and Unbalanced Audio Jack output and having Handheld and Lapel Microphones.(Model: AHUJA AWM700UHL or equivalent)
283OD149066/2022-2023:Supply and fixing of 20 mm rigid PVC conduit (white/ ivory) with IS 9537 / 1983 Part III – conforming to ISI standard with all accessories.
284OD149067/2022-2023:Supply and laying of ISI standard 2 x 1.5 mm Oxygen free Speaker cable through the existing conduit
285OD149068/2022-2023:Supply of Good quality Microphone Floor stand having 350 - 530mm Height and 150mm Base diameter.
286OD149076/2022-2023:Supply of good quality Multi Wood Rack having minimum 700mm width and 600mm depth, and having 2 nos. of partitions of 300 mm hight, and a sliding tray for keeping Audio mixer safely, supplied with AC Power Distibution Box having minimum 6 Nos. of ISI standard 3 pin plug points and 3m cable length.
287OD152010/2022-2023:Supply of Electronic PA Lectern System with Built-in Speaker, Wireless Microphone, detachable Gooseneck condenser microphone and reading light, 100-16,000Hz frequency response,Bass/Treable/Volume controles, MP3 Player and having 40W power output. (Good quality Audio cable of 10 metre length, to connect the Line output to the external Amplifier should be provided) (Prefered Model: AHUJA WSL-2500R or equivalent)
288OD188143/2022-2023:Providing power to stage monitor from nearest power point