| 1 | Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size boulders SS.20B and Sand,silt or other loose soil,wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may bedirectedexceptinhardrockrequiring blastinginclusive of shoring shuttering, ,and baling out water and cleaning and levelling the site etc.,complete 10 m3 |
| 2 | Foundation |
| 3 | Plinth beam |
| 4 | Supplying and filling in foundation andbasement with filling sand in layers of not more than 15cm.thick well rammed watered and compacted -1m3 etc., complete complying with standard specification. |
| 5 | Plain Cement Concrete 1:4:8 (one cement four fine aggregates and eight coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour chargesetc., complete as per standard specification |
| 6 | Centering for soffits of RCC slabs of plane surface like lintels, beams ,etc.,including strutting 3m high using mild steel sheets of size 90cm X60cm X and B.G 10 stiffened with M.S angles of size 25mm X 25mm X 3mm laid over silver Oak (C.W) joists of size 10cm X 6.5cm (spaced at about 90cm c/c )and supported dy casurina props of 10cm to 13cm dia (spaced of 75cm C/C) complying with standard specification and directed - 10 m 2 (P & D)Data 38 |
| 7 | Column |
| 8 | Plinth beam |
| 9 | Slab and beam |
| 10 | Supplying, fabricating and placing in position M.S. or R.T.S. reinforcements grill for RCC works as per the design given including cost of steel and binding wire etc., complete complying with standard specification. (The contractor will have to make his own arrangements for the supply of M.S. plain rods / RTS rods and binding wire) |
| 11 | Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS staandards. (No separate payment will be made by the Department for the excess usage of materials) |
| 12 | Below GL |
| 13 | Ground Floor |
| 14 | Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54.Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being \"32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers.etc., complete.-1 m 3 |
| 15 | Finishing the top of roof with one course of machine pressed tiles of size 200 mm x 200 mm x 20 mm of approved quality in Cement Mortar 1:3 (One Cement add three sand) 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete |
| 16 | Brick work in CM 1:5 (one cement & five sand) using II class ground moulded country bricks of size 8 3/4 \" X 4 1/4\" X 2 3/4\" including finishing, curing,etc., complete complying with standard specification |
| 17 | Up to basement |
| 18 | Above Basement |
| 19 | Brick Partition Walls using II class ground moulded chamber bricks of size 9\"X43/8\"X 23/4\"in C.M 1:3using hoop iron reinforcement,if found necessary standard specification including finishing, curing,etc., complete complying with standard specification - 10 sqm |
| 20 | Supplying and filling in foundation andbasement with Stone Dust in layers of not more than 15cm.thick well rammed watered and compacted -1m3 etc., complete complying with standard specification. |
| 21 | Plastering with cement mortar (1:5),12 mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306) |
| 22 | Plastering with cement mortar 1:3,10 mm ,thick in all floors including cost and conveyance of all materilas to site and labour charges etc,complete as per standard specifications (S.I.306) |
| 23 | White washing two coats with freshly burnt shell lime white in colour in all floors including cost of lime and other materials brushes scaffolding charges etc.complete complying with standard specification and as directed. -100sq.m S.I.333 |
| 24 | Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris, putty, wherever required etc., complete complying with standard specification. |
| 25 | Paving the floor with Vitrified Marbonite tiles of approved quality and colour of size 610x610x10mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3(one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer.The colour & quality of tiles should be got approved by Municipal Engineer before use on work |
| 26 | Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (one cement and three sand ) 20mm thick laid in-situ and pointed with same coloured cement |
| 27 | Dadooing walls withGlazed tiles of sizes 305mm X200mm X 6mm size of approved make and quality and colour l Set in cement mortar 1:2 (one cement ,two sand) over 10 mm base layer plastering and pointing with white cement neatly as directed. |
| 28 | Supplying and fixing in position Cement basedhydrualically pressed Anti-Skid tiles (Eurocon type tiles) 20 mmthick in cement mortar 1:3; 20 mm thick & pointed with same colour ofcement etc., complete |
| 29 | Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification |
| 30 | Fabricating Supplying and fixing in position of Aluminium anodised natural colour matt finish of single leaf door with half panelled with 12mm thick both side laminated particle board at bottom and half glazed using 5.50mm thick Plain glass at top.The outer frame shall be with aluminium box section 101.60x44.45x3.18m at 2.319kg/m and Shutter frame made ofsection Vertical & Top rail: 50x44.45x2.50mm @ 1.292 kg/m ,Bottom rail: 100 x44.45 x 2.50mm@ 1.974 kg/m, Lock rail : 50x44.45x2.5mm @ 1.292 kg/m, Alu Clips: 17.15x17.27x1.50mm @ 0.176 kg/m,Alu. Handle: 100x30mm @ 0.988 Kg/m and necessary accessories such as aluminium clips, rubber beading, PVC felt, handle for a length of shutter (both sides), locking arrangements, furniture fittings such as aluminium tower bolts-250x12mm - 1 No., aluminium tower bolt 200x12mm - 1No., aluminium Hydraulic door closer - 1No ., lock-1No., Door stopper with rubber bush including cost of materials labour charges and power consumption charges required for fabrication including chipping, dismantling and making hole to the required extent in RCC column, beams, masonry with power drill wherever necessary and redoing the damaged portion to the original condition after fixing etc., complete. All the Alu. Section are to be anodised with matt finish under electricaly controlled conditions in accordance with IS 1868/1962 for an average anatic film thickness of 15 microns etc., complete.Aluminium sections,and furniture fittings shall be got approved by the Executive Engineer incharge. |
| 31 | Main door - Double leaf (1.20m x 2.50m size) |
| 32 | Door - Single leaf (0.90m x 2.10m Size) |
| 33 | Door - Single leaf (0.75m x 2.10m Size) |
| 34 | Window - Double leaf ( 1.20m x 1.20m size) |
| 35 | Ventilator ( 0.60m x 0.45m size) |
| 36 | Supplying and fising in position Stainless Steel Handrails matt natural finish 80mm dia Pipe of size 2mm thick with 25mm dia vertical standing SS pipes at every 1.00m interval and to a height of 800mm from the finished floor level at step no sings fixed at 150mm intervals in two numbers for each steps with necessary screws, plugs etc., including providing holes in the RCC masonry step/landing or floor and also fixing the SS tubes fixed in the step 400mm depth and grouted with cement and redoing the damaged position to the original condition. The cost includes cost of all materials, labour charges,dismantling charges wherever necessary redoing works, drilling for fabrication incluing power supply and including conveyance of all materials to the site of work etc.,complete and as directed by the departmental officers |
| 37 | Supplying and fixing in position Indian water closet of size 580 X 440mm, white glazed earthen ware of approved quality with \"P\" trap or \"S\" trap confirming to IS:2556 -Part XII with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete1:2:5 ( one part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connection to cast iron soil pipes/ PVC pipes by dismandling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without leakage etc., complete complying with standard specifications and as directed by the departmental officers. |
| 38 | Supplying and fixing in position White Glazed European Water Closet of best quality and approved make with 100mm \"P\" os \"S\"\" trap with Double flapped rigit P.V.C. seat cover with C.P. brass hinges with 12.5 litres PVC Low Level Flushing Tank with all internal fittings etc., complete complying with standard spoecifications,labor inclusive of fixing lowlevel flushing tank. |
| 39 | Wiring with 2 x 22/0.3mm PVC insulated multistrand copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall and covered with hylum sheet of 3mm thick with TW switch box and making good of the concealed portion with suitable colour for PVC concealed light point( 5 points / coil) SD18 |
| 40 | Wiring with 2 x 22/0.3mm PVC insulated multistrand copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall and covered with hylum sheet of 3mm thick with TW switch box to house the fan regulator and control switch and making good of the concealed portion with suitable colour for PVC concealed fan point (5 points / coil) SD19 (For Electronic Regnlator) |
| 41 | Wiring with 2 x 22/0.3mm PVC insulated multistrand copper conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall and covered with hylum sheet of 3mm thick with TW switch box of 150mm x 100mm x 113mm for5 5A 3 pin nin-interlocking flush type CS plug with continuous earthwire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for cealed plug point. SD38 |
| 42 | Supply and fixing of 4\"40 W single industrial type flu.fitting complete with copper choke and condenser with conduit pipe suspension from the ceiling with PVC unsheathed Copper leads from the terminals to the fitting with flu.tube. (SD88) |
| 43 | Supplying and fixing of 1200mm (48\") Sweep AC ceiling fan complete with slepped electronic 300w regulator with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18\") |
| 44 | Supplying and fixing in position best quality P.V.C soil/ waste pipes (6KSC) of various sizes having ISI mark and providing leakproof joints including fixing to the wall with P.V.C/ M.S clamps etc., and making connection to all sanitaryfittings, dismandling masonry/R.C.C. works wherever necessary and making good the dismandled portion to the original condition, complying with standard specifications. |
| 45 | Supply and fixing of 16 amps Ariel fuse unit |
| 46 | Supply and run of 4 X 6 (84/0.3) PVC insulated Sc unsheathed cu.conductor of 1100v on 7/20 Gi bearer wire for Service connection mains SD68 |
| 47 | Supply and fixing of TNEB meter Board suitable for 32A three phage service connection with 3 nos. 32A aerial fuse unit (500V) 32A natural link and earth (1”x1/8” copper flat) on TW plank of size 600mm x450mmx19mm with supporting TW reepers of 1” thick an either side with paining with suitable bolt and for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copperwire EB motor to fuse unit (SD 127). |
| 48 | Supply and fixing of 16 ampsDPN mettle clad main switch. Earthing with chare coal and solt on earth through32mmG.I pipe and metal wire etc completed. |
| 49 | Supply and fixing in position of HDPE tank of 2000 Litre capacity including loading, unloading transportation and labour charges for fixing G.I pipes and specials for pipe connection works with isi mark etc completed. |
| 50 | Internal Water Supply - P.V.C. Pipes (6Kg/SqCm) Supplying laying and jointing P.V.C pipes (6Kg/SqCm) of approved quality and best variety conforming to I.S.S & with I.S.I mark, of the following sizes including cutting , Fixing to PVC specials using Adhesive but excluding cost of such specials and fixing to wall with necessary teak - Wood Plugs,PVC Clamps and screws,making holes on the wall or drilling holes in roof and making good the dismantled portions to original condition with necessary brick work and plastering wherever necessary with necessaryscaffolding charges. |
| 51 | 20mm PVC pipes |
| 52 | Cost of Wash Hand Basin, Cost of 15mm dia G.M. Wheel valve, Cost of 32mm dia C.P. waste union, Cost of 32mm dia P.V.C. waste pipe, Cost of 15mm dia brass nipple, Cost of 12/15mm dia C.P. piller tape, Cost of15mm dia nylon connection, Cost of Plug and Chain, Cost of C.I. brackets |
| 53 | Suppling and fixing in position15mm.diameter brass / C.P screw down tap / pillar tap / swan neck tap (heavy duty) of approved make conforming to I.S.specifications and quality including cost of shellac , thread etc.complying with standard specifications and including cutting and threading wherever necessary |
| 54 | Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of \"U\" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification. |
| 55 | Supplying and fixing in position CI manhole covers with CI frames (Heavy duty) of size 60cm x 60cm of best approved quality as per standard specification etc., complete compying with standard specifications |