| 1 | Taking down chowkhats or frames n.exc 1.5 Sqm (without taking off shutter from the frame) each and making good the disturbed surface complete all as specified and directed. |
| 2 | Taking down chowkhats or frames exc 1.5 sqm but not exceeding 4 Sqm (without taking off shutter from the frame) each and making good the disturbed surface complete all as specified and directed. |
| 3 | S&F powder coated aluminium frame (minimum thickness of powder coating 50 micron) for doors, windows, ventilatros etc with one or more rebates including jointing cleat for fixing etc complete all as specified and directed. |
| 4 | S&F Powder coated aluminium windows made out of aluminium tubular frame of section 63.5 x 38.10 x 1.6 mm thick and shutterfixed, sliding or openable horizontal and verticalmembers of aluminium section 47.50 x 44.45 x1.6 mm thick, aluminium beading, rubber gasket and completeincluding aluminium fittings such as hinges tower bolt, stay rod and handle complete all as specified and directed.Note :-Sheet glass shall be measured and paid separately design and pattern of aluminum windows shall be as approved. |
| 5 | S&F 4.80mm thick tinted glass with glazing clips rubber beading and aluminium beading for aluminium door/window of any size complete all as specified and directed. |
| 6 | S&F Toughned glass 10 mm thick fixed to windows frame work including cutting to shape, drilling holes required complete all as specified and directed. |
| 7 | Demolition of brick work built in cement mortar including all quoins, arches, pillers etc complete all as specified and directed. |
| 8 | S&F brick work with Sub class B bricks straight or curved on plan exceeding 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 9 | M&L for 15mm thick rendering plaster in CM 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement etc complete all as specified and directed. |
| 10 | Dismantling wall and ceiling board (Fibre, pulp, insulation etc) or insulation board /slab/blankets any thickness including cover fillet etc complete all as specified and directed. |
| 11 | S&F Gl frame work for seamless false ceiling/wall comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel at 457 mm centre to centre complete all as specified and directed. |
| 12 | S&F hangers rod of 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and directed. |
| 13 | S&F for providing Gypsum boards 12mm thick in ceiling fixed with screws as per manufacturer\"s instructions including jointless finishes with jointing compound and jointing tapes Including taking down and refixing E/M fixtures/fittings andreconnecting wiring connection complete all as specified and directed. |
| 14 | M&L for preparation of new surfaces of ceiling surface and applying two coats of plastic emulsion paint complete all as specified and directed. |
| 15 | M&L for complete removal of the existing surface of wall and applying two coats of plastic emulsion paint over 2 mm thick wall care putty (each layer minimum 1mm thick) complete all as specified and directed. |
| 16 | M&L for preparation of new surfaces of walls and applying two coats of plastic emulsion paint over 2 mm thick wall care putty (each layer minimum 1mm thick) complete all as specified and directed. |
| 17 | M&L for POP cornices decorated type on Gypsum board false ceiling of approved design and pattern along with wall and ceiling joints and on flat surfaces etc up to 150 mm widthfixed with cadmimum plated screws, complete all as specified and directed |
| 18 | M&L for POP cornices decorated type on Gypsum board false ceiling of approved design and pattern around ceiling fans, light points etc in any shape on ceiling surfaces fixed with cadmimum plated screws complete all as specified and directed |
| 19 | M&L treating the floor and surfaces of brick walls using emulsion @ one liter per hole, 300 mm apart including drilling and plugging 12 mm dia holes with CM 1:2 to match the surfaces complete all as specified and directed. |
| 20 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 21 | M&Lfor fully vitrified ceramic tiles 9 to 10 mm thick,dark shade/ultra charged, (Square/rectangular) polished, area of each tile not exceeding 0.36 sqm, in floors etc set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles, laid over and including 15 mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed |
| 22 | All as per item Ser No 21.00 above but on vertical surfaces over 10mm thick rendering in CM 1:4. |
| 23 | S&F roller blinds consisting of aluminium head rail, of approved tint and traverse cordfixed in position complete all as specified and directed. |
| 24 | M&L PCC 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in door cills, lintles and set in CM 1:4 complete all as specified and directed. |
| 25 | M&L for 18 to 20mm thick granite stone slab laid as in floor, shelves, cooking platform, pillars, cills etc machine cut bedded and jointed with grey cementslurry and pointed with white cement with admixture of pigment to match the shade of granite stone including necessary grinding, moulding and polishing and bevelling half round edges of stones laid over and including 15 mm thick screed bed in CM 1:4 etc complete all as specified and directed. |
| 26 | S&F Mild Steel framed work such as guard bar/grills welded to window frame or fixed independently, gratings etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, wall ways, railings, framework of water tanks and similar work conforming to Fe.290. Gde-E-165 complete all as specified and directed. |
| 27 | M&L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 28 | S&F 12mm thick plain toughned glass door including necessary cutting, making holes including grouting logo embedded on glass as directed including taking down old glass doors with all fittings as mentioned below :-(a) Floor hydrolic machine- 1 No in each door shutter.(b) SS handle of size 300 mm- 2 Nos (Both side in each door shutter).(c) SS over panel set/connecting patch with pivot .(d) SS \"L\" Connector for wall to wall/ wall to glass - 8 Nos in each door shutters.(e)SS Centre lock- 1 No in each Shutter. |
| 29 | S&F 0.15 mm thick PVC film (strip type plain and transparent) pasted on glass with required adhesive complete all as specified and directed. |
| 30 | M&L for Providing and fixing metal stud wall panelling with the following specifications:- (a) Supporting system comprising 51X35X0.55 mm thick metal stud @ 600 mm C/C and 51X32 mm metal tracks at floors,middle,door level and ceiling level with joints staggered. The vertical should touch the ceiling with horizontal ceiling channel at slab/beam bottom. (b) 9 mm thick BWR plywood fixed on one side with 25 mm dry wall screwsfor the entire heightof panelling including beading on all edges of teak wood.(c) 1 mm laminate (dark for bands,light for body) up to false ceiling level.(d) All beech wood members to have natural veneerfinish work with spray malamine polish. |
| 31 | M&L for 15mm thick rendering plaster in CM 1:4 on brick work or concrete surfaces finished even and smooth without using extra cement etc complete all as specified and directed. |
| 32 | S&F aluminium powder coated section door shutters consisting top rail and style82.77X44.45X1.60 mm thick bottom and lock rail 150X44.45X1.60 mmincluding jointing clips, aluminium snap beading, rubber gasket, glazing clips, two aluminium handles of size 200mm, 01 No tower bolt 200 mm, necessary hinges per leaf complete all as specified and directed.Note:-Glass and boards shall be measured and paid separately. |
| 33 | S&F double action floor spring hydraulic regulated made up of minimum 1.25 mm thick aluminium alloy sheets foundation box, main body with stainless steel cover complete all as specified and directed. |
| 34 | S&F framed work as in doors, gates of angle or other sections with gusset plate, rails brace etc conforminfg to Fe-410-W GdeE-250 complete all as specified and directed. |
| 35 | S&F 1.60 mm thick mild steel plain black sheet as in steel gate and similar works cut to size, hole, punched including rounded head screwed complete all as specified and directed. |
| 36 | Excavation in trenches in hard /dense soil not exceeding 1.5 Mwide and not exceeding 1.5 M deep and getting out in hard/dense soil complete all as specified and directed. |
| 37 | Removing excavated materials as in soilto a distance of exceeding 1.5 KM and not exceeding 5 KM out side the MOD land complete all as specified and directed. |
| 38 | M&L PCC 1:4:8, type D2 (using 40mm grade stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 39 | M&L RCC M-25 design mix using 20 mm graded stone aggregate as in foundations, raft, plinth beam, base of column etc complete all as specified and directed. |
| 40 | M&L RCC M-25 design mix using 20 mm graded stone aggregate as in column, pillers etc complete all as specified and directed. |
| 41 | Use and waste of form work to sides of concrete foundation, footings, raft, base of column etc and side and sifit of plinth beams and similar work rough finished flat surfaces complete all as specified and directed. |
| 42 | Use and waste of form work to sides of concrete colums, Pillers rough finished Square, rectangular surfaces complete all as specified and directed. |
| 43 | M&L TMT bars 10 mm dia and over cut to length bent to shape required including crancking, bending, binding etc with wire not less than 0.9 mm dia complete all as specified and directed. |
| 44 | M&L TMT bars5 mm dia and over up to 10 mm dia cut to length bent to shape required including crancking, bending, binding etc as in stirups, spacers and binders complete all as specified and directed. |
| 45 | S&F stair framed including stringers, trades, landing, balusters, hand rail, purline etc including cleats, brackets etc conforming to Fe-410W Gde-250 complete all as specified and directed. |
| 46 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheets 0.50 mm thick of any colour as in roof covering fixed with self tapping screws complete all as specified and directed. |
| 47 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick as in any type of complete all as specified and directed. |
| 48 | M&L preparation of old decorated wall surfaces and applying two coats of distemper oil emulsion complete all as specified and directed. |
| 49 | M&L for preparation of old decorated suface by brooming, closing of minor holes, preparation of corners, edges etc by using required putty up to four storied buildings and applying one coat of acrylic exterior emulsion (weather proof) painton walls,parapets, facia, soffit of projections and other surface complete all as specified and directed. |
| 50 | Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in width and not exceeding 1.5mtr in depth for fuoundation and getting out complete all as specified and directed. |
| 51 | Excavation in post holes (or similar holes) each not exceeding 0.5 cum getting out, in soft or loose soil, returning filling in and ramming earth or broken rubble mixed with earth around, in layer not exceeding 25 cm complete all as specified and directed. |
| 52 | Surface excavation not exceeding 30 cm deep and avaraging 15 cm deep and getting out in hard/dense soil complete all as specified and directed. |
| 53 | M&L for MS framed work of angle, tee, chennel, hollw pipes, conforming to Fe-290 (Gde E-165), as in Poles/Pillar/Purline/Rafter including distance pieces, cleats etc. welding or riveted complete all as specified and directed. |
| 54 | M&L rolled mild steel in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes including rivetting, welding etc confirming to Fe-410 W Gde-E-250 complete all as specified and directed. |
| 55 | M&L PCC 1:2:4 type B2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 56 | M&L PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in 75 mm thick sub base of floors complete all as specified and directed. |
| 57 | M&L for providing and laying 60 mm thick factory made chamfered edges cement concrete paver block of M-35 grade with approved colour, design and pattern as in footpath, park, lawns or light traffic parking etc of requred stength, thickness, size, shape made by table vibrating method using PU mould laid in requred colour and pattern over and including 50 mm thick compacted bed of fine sand, commpacting and proper embedding/laying of interlocking paver block in sand bedding layer through vibrating compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 58 | M&L PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in bounding of edges of interlocking tiles, coping and the like including watering & lightly rounded or chamfered angles and throating complete all as specified and directed. |
| 59 | Removal of demolished material/malba with alead exceeding 1.5 KM but not exceeding5 KM (including material loading and unloading) outside the MoD land complete all as specified and directed. |
| 60 | M&L Chequered cement concrete tiles coloured 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors using with grey cement and pigment, over and including 20 mm thick CM 1:6 complete all as specified and directed. |
| 61 | Taking down carefully unserviceable aluminium point wiring for light/socket/power socket complete, including fixtures and fitting such as switches, ceiling roses, pendents, regulators, socket for taking credit and making good disturbed surfaces on walls, ceiling, floors etc complete all as specified and directed. |
| 62 | M&L for point wiring for one light/fan point controlled by one switch concealed type with PVC insulated unsheathed copper cable FRLSH 1.5 sqmm multi stranded two single copper conductor in and including suitable size PVC conduit pipe 20 mm dia complete with all accessories and with 1.5 Sqmm PVC insulated copper cable FRLSH contineous earth wire, re-recessed mounting pressed steel GI sheet box 2 mm thick suitable for modular switch/socket of adequate size including iner and outer white cover plate of modular complete all as specified and directed. |
| 63 | All as per item Ser No 62.00 above but for one 3 pin 6 Amps socket outlet on same board board. |
| 64 | All as per item Ser No 62.00 above but 2.5 sqmm for one 3 pin 6 Amps socket outlet on independent board. |
| 65 | M&L for power point wiring concealed type with PVC insulated unsheathed copper cable FRLSH 4 sqmm multi stranded two single copper conductor in including PVC conduit pipe 20 mm dia complete with all accessories and with 4.0 sqmm PVC insulated copper cable FRLSH continous earth wire, re-recessed mounting pressed steel GI sheet box 2.0 mm thick suitable for modular switch/sockets including inner and outer cover plate of adequate size complete all as specified and directed. |
| 66 | S&F in replacement of modular switch single pole one way6 Amps 1 module complete all as specified and directed |
| 67 | S&F in replacement of modular switch single pole one way 16 Amps 1 module complete all as specified and directed |
| 68 | M&L in replacementof modularsocket 6 A/16 amp -3/5 pin combined 2 module complete all as specified and directed. |
| 69 | M&L in replacementof modularsocket 6 A-2/3 pin combined 2 module complete all as specified and directed. |
| 70 | S&F in replacement ofceiling rose, surface bakelite 65x50mm three terminals complete all as specified and as directed |
| 71 | S&F in replacement offan step regulator, 120W, 2 Module complete all as specified and directed. |
| 72 | S&F in replacement of unseviceable LED light with new 42W LED recess mounted bakalite panel 2 x 2 luminaire suitable for surface/grid ceilingfor low ceiling applications complete with tube, driver and connecting cable including making electric connection to ceiling rose or connector complete all as specified and directed. |
| 73 | S&F 12W LED recessed mounted downlighter with pressure dia cast aluminium heat sink & pc diffuser in white powder coated finish with integrated driver housing suitable for dia 138mm and connecting cable including making electric connection to ceiling rose or connector complete all as specified and directed. |
| 74 | S&F in replacement of MCB distribution board double door vertical type made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating, TPN 8 way. 415 volts with bus bar rating 200 Amps, dust and vermin proof and IP 43 - IK 09 protection suitable for incorporation of MCCB, including grouting in the wall, cutting & chasing etc complete all as specified and directed. |
| 75 | S&F in replacement of sheet metal enclosure, SPN type with two pin & earth plug and socket Industrial type DB with and including one MCB SP, C Curve type of capacity 25 Amp, 10 KA complete all as specified and directed. |
| 76 | S&F miniature circuit breaker (MCB) of 6-32 Amps SP 240V, 10KA \"C\" curve and current carrying capacity in the MCB DB complete with connection testing and commissioning including taking out old unserviceable MCB complete all as specified and directed. |
| 77 | S&F of MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA including taking out old unserviceable MCCB complete all as specified and directed. |
| 78 | M&L in replacement of sub main wiring with four run of single core PVC insulated FRLSH stranded copper conductor cable of size 16 Sqmm and two run of 16 Sqmm PVC insulated FRLS copper conductor cable as earth continuity conductordrawn in and including rigid PVC conduitconduit concealed medium grade complete all as specified and directed. |
| 79 | M&L in replacement of sub main wiring with two run of single core PVC insulated FRLSH stranded copper conductor cable of size 4 Sqmm and one run of 4 Sqmm PVC insulated FRLSH copper conductor cable as earth continuity conductordrawn in and including PVC rigid conduit concealed medium grade complete all as specified and directed. |
| 80 | S&F PVC trunking of size 50 x 105 with body and cover 01 - compartment complete all as specified and directed. |
| 81 | S&F concealed TelephonesocketRJ-11 Module 1 with complete inner,outer plate and GI sheet metal flush box 1 module 2.0 mm thick with shutter complete all as specified and directed. |
| 82 | S&F concealed Information socket category 6 RJ-45 Module 1 with complete inner,outer plate and GI sheet metal flush box 1 module 2.0 mm thick with shutter complete all as specified and directed. |
| 83 | Material and Labour for earthing complete with GI earth plate electrode600mm x 600mm x 6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below and above 15 cmof earth plate.GI plate connected with galvanised iron strip of 25x4mmby means of Copper nuts, bolts and washers.Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following:-(a)GI strip of size 25mm x 4mm. (b) Watering pipe GI lightgrade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits)(c) PCC earth pit 30x30x30cm internal dimension constructed in PCC 1:2:4 type B1 exposed surfaces smoothlyfinished with 15mm thick cement mortar 1:6 plaster including RCC 1 :2:4 type B0 reinforced with 8mm dia deformed bars @100 mmc/c bothways pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.(d) Angle iron frame made of 40x40x4 mmfor 30x30 cm PCC pit for holding the pit cover.(e ) Apply two coat of syntheticnenamel paint over one coat of red oxide zinc chrome primer on exposed steel surfaces and two coat of hot tar on embedded portion of steel surfaces. |
| 84 | M&L in replacementEarth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc. as required25x4mm galvanised iron strip complete all as specified and directed. |
| 85 | S&F detectors complying with and type certified to EN-45 addressable type multisensor detector with heat and smoke combination complete all as specified and directed. |
| 86 | Supply and laying of twisted 2 core 1.5 Sqmm shieldedPVC insulated FPLP cable for fire alarms control cable ISI Marked unsheathed multistranded cable copper conductor including makeing connection with existing Fire Alarm panel complete all as specified and directed. |
| 87 | S&F of 20mm dia MS conduit concealed/surface in wall/ceiling/above false ceilingand all fixing accessories/ materials including taking down old MS conduit complete all as specified and directed. |
| 88 | S&F remote response indicators complete all as specified and directed. |
| 89 | S&F response indicator unit complete all as specified and directed. |
| 90 | Supply and install cassette type units indoor/outdoor complete with cordless remote control unit, twin rotary compressor, single phase units 220V - 240V, 50 Hz of capacity 2.0 TR complete all as specified and directed. |
| 91 | S&F voltage stablizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation 170V to 250V with accuracy of2.5% and of capacity 5 KVA complete all as specified and directed. |
| 92 | M&L for sheet metal enclosures with plug top and MCBs single pole and natural enclosures with two pin and earth plug and socket complete with one single pole MCB 32A capacity complete all as specified and directed. |
| 93 | M&L for submain wiring along with earth wire with the 2x6.0 Sqmm+ 6.0 Sqmm earth wire of FR LSH PVC insulated copper conductor single core cable in and including conduit pipe 25 mm external dia medium grade including all accessories complete all as required or complete all as specified and directed. |