Rural Engineering Services-RES has published Tender For Modernization Work Of District Disaster Management Authority Building, Udham Singh Nagar.. Submission Date for this Tender is 12-01-2023. Building Work Tenders in Udam Singh Nagar Uttarakhand. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 11-Jan-2023 | DATE | Date | 12-01-2023 |
Sl. No. | Item Description |
1 | Earth work in excavation by mechanical means (HydraulicExcavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil asdirected, within a lead of 50 m.in all kinds of soil. |
2 | Filling available excavated earth (excluding rock) in trenches, plinthsides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, leadup to 50 m and lift upto 1.5 m. |
3 | Supplying and filling in plinth with Jamuna sand under floors, includingwatering, ramming, consolidating and dressing complete |
4 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centring and shuttering - -All work upto plinth level in 1:4:8(1Cement:4coarsesand:8gradedstoneaggregate 40 mm nominal size). |
5 | Providing and laying in position cement concrete of 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) |
6 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth inCement mortar 1:4 (1 cement : 4 coarse sand) |
7 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth inCement mortar 1:6 (1 cement : 6 coarse sand |
8 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) |
9 | Providing and laying in position specified grade of reinforced cement concrete1:1.5:3(1cement:1.5coarse sand: 3gradedstoneaggregate 20 mm nominal size) |
10 | Reinforced cement concrete work in walls (any thickness), includingReinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate20 mm nominal size) |
11 | Reinforced cement concrete work in Beam,suspended floor roof having slop up to 15 degree landing balcony shelf chajjas lintels band plain windoe cillsstaircase & sprial stair case etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate20 mm nominal size) |
12 | Centring and shuttering including strutting,ropping etc. and removal of form forCentring and shuttering for foundations, footings, bases of columns, etc. for mass concrete. |
13 | Centring and shuttering including strutting,ropping etc. andremoval of form for Suspendedfloors,roofs,landings,balconiesandaccess platform. |
14 | Centring and shuttering including strutting,ropping etc. andremoval of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
15 | Centring and shuttering including strutting,ropping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Struts |
16 | ReinforcementforR.C.C.workincludingstraightening,cutting,bending, placing in position and binding all complete. TMTbars Fe500D |
17 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. as required.Ingratings,frames,guardbar,ladder,railings,brackets,gates and similar works. |
18 | Providing and fixing T-iron frames for doors, windows and ventilators of mildsteelTee-sections,jointsmitredandweldedwith15x3mmlugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with dashfastenerorwithfixingclipsorwithboltsandnutsasrequire includingfixingofnecessarybutthingesandscrewsandapplyinga priming coat of approved steel primer. |
19 | ProvidingandfixingM.S.Tubularframesfordoors,windows, ventilatorsand nuts asrequired including fixingofnecessarybutthinges andscrews and applyinFixing with 15x3 mm lugs 10 cm. long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 ( 1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
20 | 12 mm cement plaster of mix1:6 (1 cement : 6 fine sand |
21 | 15 mm cement plaster on rough side of single or half brick wall of mix1: 6 (1 cement: 6 fine sand) |
22 | ProvidingandfixingIstqualityceramicglazedwalltilesconformingtoIS : 15622 (thicknessto be specified by the manufacture ) of approvedmake in all colours, shades except burgundy, bottle green, black of anysizeas approvedbyEngineer-in-Charge inskirting, risersof stepsanddados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarsesand)and jointingwith greycementslurry@3.3kg persqmincludingpointinginwhitecementmixedwithpigmentofmatchingshadecomplete. |
23 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 60x60 cm |
24 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
25 | Providingandfixingglassstripsinjointsofterrazo/cementconcrete floors. 40 mm wide and 4 mm thick. |
26 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
27 | Providing and fixing ISI marked oxidised M.S. sliding door bolts withnuts and screws etc. complete :300x16 mm |
28 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, 200x10 mm |
29 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS125 mm |
30 | Providing and fixing aluminium hanging floor door stopper ISI marked anodisedTwin rubber stopper |
31 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows alll complete.With 4.0 mm thick glass panes. |
32 | Providing & fixing fly proff wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 m and nuts & bolts complete.Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides. |
33 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying:(a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm.(c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around.(d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately.For the purpose of measurement the entire treated surface will be measured. |
34 | 12 mm cement plaster finished with a floating coat of neat cement of mix 1:3 |
35 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. |
36 | Concealed pipe with anti corrosive bitumastic paint, cutting chases and making good the wall15 mm dia nominal bore |
37 | Concealed pipe with anti corrosive bitumastic paint, cutting chases and making good the wall 20 mm dia nominal bore |
38 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. (external work)15 mm dia. nominal bore |
39 | Providing and fixing brass stop cock of approved quality15 mm nominal bore |
40 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)20MM nominal bore |
41 | Providing and fixing ball valve (brass) of approved quality completeHigh or low pressure with plastic floats15 mm nominal bore |
42 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
43 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms15mm nominal bore.. |
44 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893115 mm nominal bore |
45 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15mm nominal bore. |
46 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115 mm nominal bore |
47 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work)15 mm nominal bore |
48 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work)20 mm nominal bore |
49 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mmWhite Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. |
50 | Providing and fixing white vitreous china pedestal type water closet (European typeW.C. pan with ISI marked white solid plastic seat and lid |
51 | White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C. brass pillar tap. |
52 | Providingandfixingwhitevitreouschinasquattingplateurinalwithintegral rim longitudinal flush pipe. |
53 | Providingandfixingwhitevitreouschinaflatbackorwallcornertypelippedfronturinalbasinof430x260x350mmand340x410x265mmsizes respectively. |
54 | providing fixing 8mm diaCP/SS jet with flexible tube up to 1 meter long with SS triangular plate to eureopean type WC of quality and make as approved by engineer in charge |
55 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C.Flexible pipe32mm dia |
56 | providing &fixing PTMT 15mm urinal spreader size 95x69x100mm with 1/2"BSP thread and shapes, weighing not less than 60gms |
57 | Providing and fixing PTMT grating of approved quality and colour.100 mm nominal dia. |
58 | Providing and fixing uplasticised PVC connection pipe with brassunions :30 cm length15 mm nominal bore |
59 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements weighing not lessthan 106 gms. |
60 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finishedWith F.P.S. bricksInside dimensions 455x610 mm and 45 cm deep for single pipe line : |
61 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes75 mm diameter |
62 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes110 mm diameter |
63 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories coupler 75mm diameter |
64 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessoriescoupler110mm diameter |
65 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories single tee 75x75x 75mm diameter |
66 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessoriessingle tee 110x110x110mm diameter |
67 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories bend75mm diameter |
68 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessoriesbend 110mm diameter |
69 | Finishing walls with Acrylic Smooth exterior paint of required shadeNew work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm). |
70 | providing and applying white cement based putty of average thickness 1mm of approved brand and manufacture, over plastered wall surface to prepare the surface even and smooth complete |
71 | Distempering with 1st quality acrylic washable distemper (ready made) of approved manufacturer and of required shade and colour complete, as per manufacturer’s specificationTwo or more coats on new work. |
72 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shadeTwo or more coats on new work |
73 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C.projections. |
74 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honeycomb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m longcomplete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
75 | Providing and fixing stone slab with table rubbed, edges rounded andpolished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embeddingthe stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size)as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail