Military Engineer Services-MES has published Tender For Provision Of Switch Sockets For Charging Points In Lal And Latif Billets With Associated Works At Ats Belagavi. Submission Date for this Tender is 23-01-2023. Electrical Products Tenders in Belagavi Karnataka. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 16-Jan-2023 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 23-01-2023 |
Sl. No. | Item Description |
1 | M & LSub main wiring two single core 1.5 sq mm FRLS PVC insulated copperconductorcables,1100Volts grade drawn through and includingsuitable size of non-metallic PVC rigid conduit / casing and capping with accessoriesfixed up on walls, roofs, or floors includingone run of 1.5 sqmm FRLS PVC insulated copper conductor cable as earth continuity conductor and connecting up complete all as specified and as directed. Note : Three runs of 1.5 sqmm copper conductorand one run of PVC casing and capping / PVC conduit shall be measured as one unitlength. |
2 | M & LSub main wiring two single core 2.5 sq mm FRLS PVC insulated copperconductorcables,1100Volts grade drawn through and includingsuitable size of non-metallic PVC rigid conduit / casing and capping with accessoriesfixed up on walls, roofs, or floors includingone run of 2.5 sqmm FRLS PVC insulated copper conductor cable as earth continuity conductor and connecting up complete all as specified and as directed. Note : Three runs of 2.5 sqmm copper conductorand one run of PVC casing and capping / PVC conduit shall be measured as one unitlength. |
3 | M & LSub main wiring two single core 4 sq mm FRLS PVC insulated copperconductorcables,1100Volts grade drawn through and includingsuitable size of non-metallic PVC rigid conduit / casing and capping with accessoriesfixed up on walls, roofs, or floors includingone run of 4 sqmm FRLS PVC insulated copper conductor cable as earth continuity conductor and connecting up complete all as specified and as directed. Note : Three runs of 4 sqmm copper conductorand one run of PVC casing and capping / PVC conduit shall be measured as one unitlength. |
4 | M & LSub main wiring two single core 6 sq mm FRLS PVC insulated copperconductorcables,1100Volts grade drawn through and includingsuitable size of non-metallic PVC rigid conduit / casing and capping with accessoriesfixed up on walls, roofs, or floors includingone run of 6 sqmm FRLS PVC insulated copper conductor cable as earth continuity conductor and connecting up complete all as specified and as directed. Note : Three runs of 6 sqmm copper conductorand one run of PVC casing and capping / PVC conduit shall be measured as one unitlength. |
5 | S & F sheet metal enclosure factory made double door distribution board SPN 4 way, 240 volts, 200 Amps rated bus barcomplete all as specified and as directed |
6 | 6. S & F sheet metal enclosure factory made single door distribution board 240 voltsSPN 2 Way complete all as specified and as directed. |
7 | S & FMCB,Single Pole Neutral 6 to 32 Amps, C Curve, 240 volts, 50 Hz AC supply complete all as specified and directed. |
8 | S & F MCB, Single Pole 6 to 32 Amps, C Curve,240 volts, 50 Hz AC supply completeall as specified and directed. |
9 | S & FSwitch Socket combination,2 in 1, 3 pin5 Amp flush type (Gang Box) 240 volts completeall as specified and directed. |