Municipal Council -MC has published Tender For Construction Of Stambha,Barricade ,Shed Work And Internal Electrification Ward No-10 And 11. Submission Date for this Tender is 31-12-2022. Barricades Tenders in sonepur Odisha. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Earthwork in excavation in hard soil for site leveling, foundation, pits, trenchesand other civil works upto and including 1.5metre lift and stacking the soil upto a lead of 100 metre and including dewatering,removingslush,shoringand strutting(asrequired), complete as per specification and as directed by the Engineer-In- Charge.Hard soils. |
2 | Filling at all depth with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 15cm in depth: consolidating each deposited layer by ramming and watering complete (lead upto 100m) as directed by the Engineer-In-charge. |
3 | Supplying and filling sand in foundation and over areas including watering,ramming,consolidatinganddressing,labours,tools, taxesetc.allcompleteasper thespecificationanddirectionof Engineer-In-Charge. |
4 | Providing and laying plain cementconcrete1:4:8 (1 cement: 4 sand: 8 stoneagregate 40mmnominal size) as levelling course in foundation and plinth etc. includingtempering, curring ,shuttering etc.complete all depth and height. |
5 | Fly Ash. brick masonryof size 25 cm. x 12 cm. x 8 cm. having crushingstrengthnotlessthan75kg.PerSqr.Cm.incement mortar of mix (1:6) with approved grade cement and screened & washedsandformortarafterimmersingthebricksfor6(Six) hoursinwaterbeforeuseinSuperstructureincludingsplays cutting, circular moulding, corbelling, chamfering and similar such type of works,watering and curing etc. including cost, conveyance, loading, unloading, royalties Ground floor |
6 | Providing, lifting, hoisting and laying Reinforced cement concrete ofM-25 grade asper approved designsand drawingshaving a minimumcompressivestrength(inworktest)250Kg./Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hardcrushedbrokengranitestonechipsandscreenedand washed sharp sand for mortar of approved quality from approved quarry, washed andcleaned ( 20mm. size chips not to exceeds.a) Footing 25%)tobemixedinconcretemixturewithPortland slag cement (PSC) including hoisting, lowering, laying and compaction concretebyusingvibrators,wateringandcuringfor28days, centeringandshutteringthenafterdismantlingandremoving debrisfromtheworksiteandfinishingtheexposedsurface smoothprovidinggroovesorbeadswherevernecessary includingcost,conveyance,loading,unloading,royaltiesand taxesofallmaterialsandcostofalllabours,sundries,T&P requiredofthe worketc.completein allrespectasdirectedby theEngineer-in-Charge.Butexcludingcostandconveyanceof M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position. |
7 | b) R.C.C Wall |
8 | c) Plinth Beam |
9 | d) Roof Beam |
10 | f) Slab |
11 | Cutting, straightening coiled or bent up M.S. Rod or torsteel of SAIL/TATA/RINL(VIZAG)makeincluding bending,binding, welding and joining if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or tor steel and binding wires of 18to20gaugeandlabourrequiredfortheworkforbending, binding and tying the grills in all floors (Linear measurement will be taken and quantity will be calculatedbasing on the standard weight of B.I.S. for M.S. Rods or tor steel only. Wastage if any, including weight of binding wire will not be considered for measurement)etc.completeasperspecification&directionof Engineer-in-charge.Ground floor |
12 | 12mm cement plaster to outside of brick surfaces with cement mortarofmix1:6(1cement:6finesand)includingnecessary scaffolding, curing etc. all complete at all floors and all heights.Ground floor |
13 | Steel ( December-2022) Ground floor |
14 | Supplying, fitting & fixing of Granite Tiles of minimum Above 0.10 Sqm & up to 0.4 sqm (10mm. thick) of approved make in dadoes laid on 12 mmthickcementmortar(1:3) (1 cement:3 coursesand)andfillingjointswithslurryincludingcostofall Ground floor |
15 | Supplying, fitting & fixing of Sand stone cladingincluding cost of all materials, labour T&P etc. required for the workall complete incl. rubbing as per direction of the Engineer-in-charge.Ground floor |
16 | Supplying, fitting & fixing of GRC brick cladingincluding cost of all materials, labour T&P etc. required for the workall complete incl. rubbing as per direction of the Engineer-in-charge.Ground floor |
17 | Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, taxes of all materials, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge.Ground floor |
18 | Painting two coats with approved anti-fungal weather seal paints (ISI)ofapprovedcolour,shadeonwallsurfaceoveracoatof wallprimer(ISI)waterboundincludingsandpapering,polishing thesurface,cost,conveyancesofallmaterialsandcostofall labour,labour cess with T&P etc, complete as per specification & direction of Engineer-in-charge.Ground floor |
19 | Earthworkin excavationin hard soil for siteleveling, foundation, pits, trenchesand other civil works upto and including 1.5metre liftandstackingthesoil uptoaleadof100metreandincluding dewatering,removingslush,shoringandstrutting(asrequired), complete as per specification and as directed by the Engineer-In- Charge.Hard soils. |
20 | Fillinginfoundationtrenchesandplinth,withexcavatedearth includinglayingtheearthinlayersnotexceeding23.5cmthick ramming&wateringwithallleads&liftsincludingcostofall labour,T&P completed as directed by the Engineer-in-charge. |
21 | Supplying and filling sand in foundation and over areas including watering,ramming,consolidatinganddressing,labours,tools, taxesetc.allcompleteasperthespecificationanddirectionof Engineer-In-Charge. |
22 | Providingandlayingplaincement concrete 1:4:8(1cement:4 sand: 8 stoneagregate 40mmnominal size) as levelling course in foundation and plinth etc. includingtempering, curring ,shuttering etc.complete all depth and height. |
23 | Providing, lifting, hoisting and laying Reinforced cement concrete ofM-25gradeasperapproveddesignsanddrawingshavinga minimumcompressivestrength(inworktest)250Kg./Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushedbrokengranitestonechipsandscreenedandwashed sharp sand for mortar of approved quality from approved quarry, washed andcleaned ( 20mm. size chips not to exceeds 25 % ) to bemixedinconcretemixturewithPortland slagcement(PSC) includinghoisting,lowering,layingandcompactionconcreteby usingvibrators,wateringandcuringfor28days,centeringand shutteringthenafterdismantlingandremovingdebrisfromthe worksiteandfinishingtheexposedsurfacesmoothproviding grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties and taxes of all materials and cost of all labours, sundries, T & P required of the worketc. complete in all respect as directed by the Engineer-in- Charge. But excluding cost and conveyance of M.S. rodsor Tor steelandbindingwiresandlabourchargesforstraightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position.Ground floor a) Footing |
24 | b) column |
25 | c) Tie beam |
26 | Cutting,straighteningcoiledorbentupM.S.Rodortorsteelof SAIL/TATA/RINL(VIZAG)makeincluding bending,binding, welding and joining if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or tor steel and binding wires of 18to20gaugeandlabourrequiredfortheworkforbending, binding and tyingthe grillsin all floors (Linearmeasurementwill betakenandquantity willbecalculatedbasingonthestandard weightofB.I.S.forM.S.Rodsor tor steelonly.Wastageifany, including weight of binding wire will not be considered for measurement)etc.completeasperspecification&directionof Engineer-in-charge. |
27 | Supplying, fitting & fixing of Granite Tiles of minimum Above 0.40 sqm.(20mmthick)ofapprovedmakeinfloorslaidon20mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with slurry including cost of all materials, labour T&P etc.requiredforthework allcomplete incl.rubbing asper direction of the Engineer-in-charge.Ground floor |
28 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position andapplyingaprimingcoatofapproved steelprimer,including welding and bolted with special shaped washers etc. complete.Ground floor |
29 | Steel ( December-2022) Ground floor |
30 | Supplying and fixing of Polycarbonate sheet Ground floor |
31 | Supplying and fixing of Twisting brick clading Ground floor |
32 | Earthworkin excavationin hard soilfor siteleveling,foundation, pits,trenches andother civilworksupto and including1.5metre liftandstackingthesoiluptoaleadof100 metreandincluding dewatering,removingslush,shoringandstrutting(asrequired), complete as per specification and as directed by the Engineer-In- Charge.Hard soils. |
33 | Fillinginfoundationtrenchesandplinth,withexcavatedearth includinglayingtheearthinlayersnotexceeding23.5cmthick ramming&wateringwithallleads&liftsincludingcostofall labour,T&P completed as directed by the Engineer-in-charge. |
34 | Supplying and filling sand in foundation and over areas including watering,ramming,consolidatinganddressing,labours,tools, taxesetc.allcompleteasperthespecificationanddirectionof Engineer-In-Charge. |
35 | Providingandlayingplaincement concrete 1:4:8(1cement:4 sand: 8 stoneagregate 40mmnominal size) as levelling course in foundation and plinth etc. includingtempering, curring ,shuttering etc.complete all depth and height. |
36 | Providingandlayingplaincement concrete 1:2:4(1cement:2 sand: 4 stoneaggregate 12mmnominal size) as levelling course in foundation and plinth etc. includingtempering, curring, shuttering etc.complete all depth and height.a) Footing |
37 | First class Fly ash Brick masonry usingbricks of size 25 cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC)andscreened&washedsandformortarafter immersingthebricksfor6(Six)hoursinwaterbeforeusein Foundation&Plinthincludingsplayscutting,circularmoulding, corbelling,chamferingandsimilarsuchtypeofworks,watering andcuringetc.includingcost,conveyance,loading,unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-Charge. |
38 | SupplyingandFixingof M.S. Grills, M.S.Doors, M.S. Gate etc includingcost,conveyance of all materials,priming,andlabour for fittingfixingetc.completeaspertheinstructionofEngineer-in- Charge |
39 | Paintingtwo coats with approved Enamel Paint on Steel work in Ground Floor |
40 | Supplying, fitting & fixing of Granite Tiles of minimum Above 0.40 sqm. (20mm thick) of approved make in floors laid on 20 mm thick cement mortar (1:4)(1 cement : 4 course sand) and filling joints with slurry including cost of all materials, labour T&P etc. required for the work all complete incl. rubbing as per direction of the Engineer-in-charge |
41 | LIGHT SYSTEMSupply ,Installation testing commissioning of POST TOP 35W, High efficient LED with aluminium housing in Pure Polyster UV resistant powder coated black finish and Top maintainable product with top opening die cast cover with acrylic clear glass reflector.CRI>70,IP66,Ambienttemp-0to 45DegC,Driver efficiency>85%, CCT-4000/5700K,THD<10%,Powerfactor>0.95,Surgeprotection-4kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 150-300V AC and Safety Extra Low Voltage Safe level<60V DC as per IEC standard.Luminairelumen=3500lumens(110lm/W).SimilartoWiproMake LP07-431-XXX-57-CL or equivalent Philips/ LT/Trilux make. & model A catogory, ISI marked as approved, with proper model make having warrantied for a period of 5 years .The luminaire to be installed in 6 mtr long GI hot dip galvanized smart polewithanticorroson,,uvraysstabilized,metalpostwithcoveredbyresin of Fumatech/Valmount/Transrail/RR/UTKASH /Utkal Galvanizer make equievalant makewithpropermodelcompletewithSAbracketinternalJBwith4way connector andMCBas per thepole drawinganddirectionof EICagainst which inspectionmattakeplace. ItshouldbeinstalledaftermakingpropersizeRCC foundationbyconsideringRCCfoundation byusingM20gradeRCC&Fe415 gradereinforcementandfixingthe4nos.En8gradeJtypefdnboltsinthe foundation. The luminaire needs to be wired with 3 c 1 sq mm wire from JB as per |
42 | Supplying, Erection, Fixing, connection & testing of LED BOUNDRY WALLLight of elegantlookPanasonic/philips/wiproorequievalantreputedmake&modelA catogory, ISI marked as approved 35 W LED street light having die cast aluminium housing with toughened glasshaving lumen efficacy of 110 lm/w or more (As per LM 79report ofthird party NABL lab) ,IP 65protection or more , LEDstreetlight modelwillbevidePanasonicmodelno.PSTM27358 orits equivalentofPhilips/LT/WIPROmake orequievalantreputedmakeA catagory ISI marked as approved having warrantied for a period of 5 years .The luminaire should be supplied along with bracketmaintenance free for inspection as required as per direction of Engg.-in-Charge. |
43 | Supplying, Erection, Fixing, connection & testing of45 LED GATE Light ofWIPRO makeorequvalantofPhilips/LT/PANASONIC orequievalantreputedmakeA catagoryISI marked as approvedmaintenance free having 2 years warrantyG.I Pipe withbraketincludingMCBbox&including withfoundationasper the Drawing for inspection as required & as perdirection of Engg.-in-Charge. |
44 | Supplying,Erection,Fixing,connection&testingof8W,HighefficientLEDwith Aluminium housing withclear toughened glass diffuser.CRI>70, IP65, CCT- 2700K,Ambienttemp-0to45DegC,Driverefficiency>85%,THD<25%, Powerfactor>0.95,Surgeprotection-2kV,MultistageIsolatedConstantCurrent- ConstantVoltagedriverandSafetyExtraLowVoltageSafelevel<60VDCas per IEC standard. Luminaire lumen = 600 lumens (75 lm/W). Similar to Wipro Make LF05 or equivalent Philips/ LT/Trilux make. as per the Drawing for inspection as required & as perdirection of Engg.-in-Charge. |
45 | Supplying ,installation & fixing of 11W, High efficient LED with extruded Aluminium housing with PC diffuser.CRI>70, IP65, CCT - 6500K, Ambient temp-0 to 45DegC, Driver efficiency>80%,THD<25%, Powerfactor>0.9, Surge protection-2 kV,Multistage Isolated Constant Current-Constant Voltage driver and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire lumen = 565 lumens (51 lm/W). Similar to Wipro Make LB12-131-XXX-65-05 or equivalent Philips/ LT/Trilux make. including with foundation as per the Drawing for inspection as required & as perdirection of Engg.-in-Charge. |
46 | Supplying ,installation & fixing of 7W, High efficient LED outdoor SPOT LIGHT with extruded Aluminium housing with PC diffuser.CRI>70, IP65, CCT - 6500K, Ambient temp-0 to 45DegC, Driver efficiency>80%,THD<25%, Powerfactor>0.9, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage driver and Safety Extra Low Voltage Safe level<60V DC as per IEC standard. Luminaire lumen = 565 lumens (10 lm/W). Similar to Wipro Make or equivalent Philips/ LT/Trilux make. including installation under water as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. |
47 | Supply of materials and installation of pipe earth electrode made out of 50mm dia class B G.I. pipe of 3.0 metre long with arrangements for fitting/ terminationof G.I. flat / wire withG. I. nutbolts& washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The |
48 | Providingandfixing4mmdiacopperwireonsurfaceorinrecessforloop earthing as required as per direction of Engg.-in-Charge. |
49 | CABLING Supplying and laying of one number PVC insulated armoured and PVC sheathed XLPEAL. conductor power cable of 1.1 KV gradePOLYCAB/FINOLEX/HAVELLSor equievalant reputedISIMARKEDMAKEoffollowingsizecablesas perdirectionofEngg.-in- Charge.Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service withinwarranty periodfor acceptance of materials 4core x 10 sq mm (OFP TO IND. TIMER PANEL) |
50 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMdirect in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
51 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 120 SQ. MM From25 SQ.MMinsurface withshaddle andscrew etcas requiredas per direction of Engg.-in -charge. |
52 | S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type MCB ENCLOSURE madeoutby2mmCRCAsteelsheetdulyderusted&pentedby simens gray powder cote paint is designed asG.A drawing. (FOR USE) with 20A TPNMCB01NOLegrand/Schneider/L&T/ABBorequievalantmake&modelas perdirectionofEngg.-in-Charge.Ncessarytestreport&Warrnatycertificatetobe submittedtothedepartmentforgenuinityofproduct&toavailfreeaftersales service within warranty period 2 years ofacceptance of materials |
53 | Supplying,layingof3cx2.5sq.mmcopperflexiblecablewithinsulatedcoverof reputedmake,ISImarkedwithallotherconcernedmaterialsasperdirectionof Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the departmentforgenuinityofproduct&toavailfreeaftersalesservicewithin |
54 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete withfitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to besubmitted to the departmentfor genuinity of product & to avail free after sales service withinwarranty periodfor 50 mm dia |
55 | S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type timer panel with 32A 4P MCB ,40A TP CONTACTOR ,TIMER with 15 nos 10A SP MCB C as per directionofEngg.-in-Charge..(Equievalant modeleach item of Legrand/Schneider/L&T/ABB or equievalant make & model)Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product &toavailfreeaftersalesservicewithinwarrantyperiodfor2yearsafter acceptance of materials. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy