Construction Of Building For Goa State Agricultural Marketing Boardat Canacona Market Sub Yard, canacona-Goa

Agricultural Produce Market Committee-APMC has published Construction Of Building For Goa State Agricultural Marketing Boardat Canacona Market Sub Yard. Submission Date for this Tender is 17-01-2023. Building Work Tenders in canacona Goa. Bidders can get complete Tender details and download the document.




Tender Notice

35324970
Corrigendum : Construction Of Building For Goa State Agricultural Marketing Boardat Canacona Market Sub Yard
Open Tender
Indian
Goa
canacona
17-01-2023

Tender Details

Construction Of Building For Goa State Agricultural Marketing Boardat Canacona Market Sub Yard

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Jan-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 10-01-2023
2 10-Jan-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-01-2023

Key Value

Document Fees
INR 8000 /-
EMD
INR 508673.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:CONSTRUCTION OF BUILDING FOR GOA STATE AGRICULTURAL MARKETING BOARDAT CANACONA MARKET SUB YARD
Sl. No. Item Description
1A-EARTHWORK
2Clearing grass and removal of rubbish upto a distance of 50 m outside the periphery of the area
3Earthwork in excavation in trenches for all leads & lifts in all type of strata comprising of any type of materials either in full or part as the case may be adopting any method/methods as may be convenient as permitted excluding blastingin all conditions such as dry, moist, foul, saturated, submerged, etc,. including dressing of sides, planking & strutting, timbering ,ramming of bottom ,pumping and bailing out water ,barricading danger lighting guarding as directed by Engineer for all leads & lifts etc. complete
4Refilling the pipeline/foundation trenches plinth sides, foundation etc. with available excavated earth in layers not exceeding 20 cm depth consolidating each layer ramming and watering lead upto 50 M and all lifts and disposal of surplus earth as directed by Engineer in Charge.
5Supplying and filling in plinth under floors, trenches including watering ramming consolidating, dressing, complete.
6Moorum
7Carting away unwanted excavate material from sitelead of 5km including allloading & unloading charges ( A ) ( by mechnaical Automative Transport ) Contractor should arrange land for dispose up these material at his own cost Lead upto 5 km.
8Laterite Stone
9B-MASONARY WORKS
10Half brick masonry using fly ash bricks in cement mortar 1:4 (1 cement : 4 coarse sand) with bricks of class designation 40 kg/cm2 including longitudinal reinforcement of 2 Nos. 8 mm diameter bar every 12th layer embedded in horizontal RCC band (1:1.5:3) Above plinth upto floor V level (200 x 95 x 95 )
11Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete.
12Rubble packing with hard laterite stone under floormade available from excavation at site, under floors including watering, ramming and consolidating etc. in pipeline trenches and other foundations etc. Complete.
13Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1cement :4 coarse sand) in foundation and basement.
14Laterite masonry in neatly dressed stones of size as specified in cement mortar 1: 4 (1cement :4 coarse sand) inallsizesin superstructure from floor I level upto floor V level.
15Pre-cast cement concrete solid block masonry of compressive strength 70 kg/cu.m in cement mortar 1:4 (1 cement : 4 coarse sand ) in Super Structure of size specified up to level 5, as per the direction of engineer in charge.
16C- PLAIN AND REINFORCED CEMENT CONCRETE
17Providing & laying cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded granitic or basaltic stone aggregate. 40 mm. nominal size) excluding cost of centering, shuttering and finishing in:
18All works upto plinth level
19Providing and laying in position machine batched concrete (BMC), machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to the site of laying but excluding the cost of centering , shuttering, finishing and reinforcement includingadmixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing the strength and durability as per the direction of the Engineer-in-charge. M30 grade of reinforced cement concrete by using 420 kg of cement per cu.m. of concrete. All works upto floor V level. (Design Mix by Ready mixed concrete ( RMC) may be used atno extra cost
20Centering & shuttering including Strutting, Propping & removal of forms for :
21Foundations, Footings, Bases for columns
22Vertical surfaces such as retaining walls, return walls, Partitions, walls (any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like
23Columns, Piers, Pillars, Abutments, Posts and struts (square rectangle polygon in plan)
24Sides and Soffits of beams, Beam Haunchings, Cantilever, Girders, bressumers and Lintels plinth beams not exceeding 1m in depth
25Staircases (except spiral staircases) excluding landing
26Suspended floors, roofs landings, shelves & their supports
27Extra to be added for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de- shuttering and de-centering at all levels, over a height of 3.5m, for every additional height of 1m or part thereof. (Plan area to be measured) Suspendedfloors,roofs,landings,beamsand balconies (plan area to be measured)
28Providing TMT steel reinforcement bars of SAIL, TATA. VIZAG made only (Confirming to IS 1786 of 1986)for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floorsalongwith the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member.
29D – WOODWORK
30Providing woodwork in frames of doors, windows, clerestory windows trusses & other frames wrought framed and fixed in position. (Second class Indian teak wood)
31Providing& fixing flush door shutters decoration type core of block board construction with frame of first class hard wood and well matched first class Indian teak ply veneeringwith vertical grains and cross bands and face veneers on both faces of shutters.( 35mm thick including anodized aluminum butt hinges with necessary screws )
32Providing flat iron hold fast 40 cm including fixing to frame with 10 mm dia bolts, nuts and wooden plugs and embedded in cement concrete block 30 x 10 x 15 cm 1:3:6 mix (1 cement: 3 coarse sand: 6 stone aggregate 20 mm nominal size.(40 x 3 mm flat iron hold fast 40 cm long)
33Standard Wood Core Door Shutter with Single Colour Manufacture, Supply and Installation (including accessories as mentioned below) of EPEE or equivalent Goan make FRP (Fiber Reinforced Polymer) door shutter of specified thickness as per options below by using tray system with seasoned hard wood, moisture less than 17%, wood styles for Top rail and lock rails. FRP (Fiber Reinforced Polymer) laminate made up of 450 grams per sq.mts (gsm) chop strand matt and unsaturated polyester resin with viscosity range of 400/450 centipoises per second (cps).The core of Shutter will be filled with MR2nd grade Block Board. The shutter to be water proof as well as mild acid /alkali resistant manufactured using RV TIFAC (R V Engineering College, Bangalore & Technology Information Forecasting & Assessment Council) technologyin line with IS 13034 1990 test Standard in an ISO 9001 – 2015 certified factory.
34i) S. S. Hinges 4”- 3 Nos ii) S. S. Latch- 1 No iii) Tower Bolt 5” - 2 Nos iv) Handle 5”- 2 Nos
35FRP(FiberReinforcedPolymer)Frames Manufacture,SupplyandInstallation(with anchorfastener)ofEPEEorequivalentGoan make FRP (Fiber Reinforced Polymer) Frame of crosssectionasperoptionsbelowwithright angle joint and FRP (Fiber Reinforced Polymer) laminate made from 450 grams per sq.mts (gsm) chop strand glass fiber (matt) and unsaturated polyester resin with viscosity range of 400/450 centipoises per second (cps). The core of frame would be filled with seasoned wood as infill material. The slot of frame for door resting will be of suitable width so as to take specified thickness door.. The frame will be water proof as well as mild acid/ alkali resistant manufactured in an ISO 9001- 2015 certified company.
36d) 5” x 2 ½ “
37Providing & fixing bright finished SS handles of SS 305 grade of steel with necessary screws etc. complete. 125 mm
38Providing and fixing bright finished SSdoor latch with necessary screws etc complete (300x 16 x 5 mm)
39Providing & fixing bright finished Stainless Steel mortise latch & lock and a pair of levers handles with necessary screws etc.complete (100mm x 150mm)
40Provided and fixing 150 mm SS floor door stopper with rubber cushion screws etc. to suit shutters thickness complete.
41Providing and fixing SS hydraulic door closer of approved make with necessary screws and fittings complete.
42Providing and fixing SS butt hinges with necessary screws etc. complete [ 125 x 70 x 4.0mm (ordinary type) ]
43Providing & fixing SS Tower Bolts (barrel type) with necessary screws complete. ( 250 x 10 mm )
44E – STRUCTURAL STEEL & ALUMINIUM WORK
45Steel work in single sections (SAIL, TATA. VIZAG & using electrodes of Ador or ES4B or Deh Secheron make only) including cutting, hoisting fixing in position
46a) In R.S. joists, channels, angles, tees
47Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 /Rectangular Hollow Section (RHS) IS4923/ Circular Hollow Section (CHS) IS1161 closed Structural Steel of approved make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position and including welding and bolted with special shaped washers etc. complete.
48Providing and fixing in position S.S. hand rail in main stair case, and landing as per approved design shown in the drawing including bending handrail pipe to proper shape in curves with specials, etc. complete.
49Providing and fixing anodized aluminium shutters in accordance with the specification annexed with Goa schedule of Rates (2004) Vol & II including all taxes, transportation, scaffolding and handling etc. complete as per direction of the Engineer-in-charge: windows with three sliding shutters using 18 mm series shutters section. b) Plain glass
50Providing and fixing anodized aluminium shuttersinaccordancewiththespecification annexed with Goa schedule of Rates (2004) Vol & II including all taxes, transportation, scaffoldingandhandlingetc. completeasper direction of the Engineer-in-charge: Adjustable louvered windows.
51Extra for powder coating with pure polyester powder of shade of required colour on the aluminum section
52Providing and fixing M.S. grill of required pattern in wooden frames of Windows etc. with M.S. flats square or round bars with round headed bolts and nuts or byscrews. (Plain Grill)
53Supplying andfixing rolling shutters of approved make, made of 80 x 1.25 mm M.S. laths interlocked together through their entirelength and jointed together at the end by end locks mountedon specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pulloperation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No.2 and M.S. top cover of 1.25mm thick for falling shutter stop cover and spring.
54F – FLOORING
55Kotah stone slab flooring over 20 mm (average) thick base laid over & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing &complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) 20mm thick
56Providing & fixing kotah stone tread tiles 20 mm thk.in single piece with half roundednosing, antiskid grooves, laid on20 mm (average) thick bed of cement mortar 1:4 (1 cement : 4 coarse sand) with neat cement slurry including pointing with pigmented cement slurry to match the shade of slab, cleaning etc. complete.
57Kotah stone slab flooring over 25 mm thick in risers of steps, skirtings, dado & pillars laid on 12mm (average) thick cement mortor 1:3 (1 cement : 3 coarse sand) & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing &polishing complete.
58Providing and fixing 18mm thick mirror polished raws silk granite machine cutfor kitchen platforms,counters, window sills, facia, Walls and similar locations of required size of approved shade, colour and texture laid over 20mm thick bas cement mortar 1:4 (1 cement : 4 coarse sand) with joints trated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edge to give high gloss finish, etc. complete at all levels.
59Providing and fixing 20mm thick black polished on either sides granite slab to urinal partions with cement etc. complete
60Providing and fixing granite in wash basin counters with base kadappah and top granite with frontand side face with granite including moulding/chamfering of edges,cutouts and fixing of wash basin/ kitchen sink etc, finishing the edges corners with grouts of matching pigments as per the direction of engineer incharge.
61Providing and fixing 1st quality ceramic glazed wall tiles (Johnson, Somany, Kajaria )conforming to IS:15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement slurry @3.3kg per sq.m including pointing in white cement mixed with pigment of matching shade complete.
62b)Wall Ceramic Glazed Tiles : 300 x 450
63Providing andlaying antiskid floor tiles 12 x 12 upto 16 x 16 in of Johnson, Somany, Kajaria(thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make in shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cement & matching pigment etc,complete(a-Dark Shades)
64Providing and fixing vitrified matt finished (600x600) and 10mm thick tiles in floor, treads of steps, landing on 25mm thick bed ofcement mortar 1:3 and jointed with cement slurry complete.
65Providing and fixing Vitrified tiles in different sizes(thickness to be specified by manufacturer), with water absorption less than 0.08%andconforming toI.S.15622,of approved make, in all colours & shade, in skirting, riser of steps and dados, jointing with grey cement slurry @3.3 kg per sqm, including pointing/grouting in white cement mixed with pigment of matching shade complete.
66Light shade
67G – ROOFING & WATERPROOFING
68Providing and fixing colour coated galvulium roofing sheets of 0.5mm thickness including all the accessories (TATA make) but excluding the costofpurlins,rafters,trusses,flashingsetc. complete as per the directions of the Engineer in charge.
69Providing & fixing Flashings -[Corners, Ridges, valleys, gable end & Trims] (Girth upto 610mm) including all the accessories complete as per the directions of the Engineer in charge.
70Providing & fixing in position Galvalume/Zincalume gutters upto 600mm/610mm girth and min 3.00m in length, factory cut at all heights for roof complete in all respects incl. fixing to purlins with mechanically galvanised hex head self drilling screws of the best quality as per AS-3566 class 3-4 approved, which should be compatible to be used with sheets. with integral washers and EPDM seals etc. Silicon sealant non-hardening neutral cure type shall be applied at all end laps, complete as directed.
71Providing water proofing treatment over the newR.C.C. roofs terrace toilet by spreading cement slurry over the R.C.C. slab andlaying of 10cms. Average laterite stone ballast coba with the necessary gradient for easy flow of rain water and the coba in covered with damp proof of Hindustan water proofing co. Or equivalent jointless water proofing plaster of mix 1:3 (1 cement: 3 find sand), finished smooth with wooden trowel with false marking of 30 cms square.The vertical surface of the adjoining walls are to be treated upto a height of 30cms including rounding of junction (the rate includes for complete items including labour and materials and including cost ofinitial treatment of roof slab as follows. The injunction of damp proof or equivalent compound with cement solution will be given as and when found necessary for filling honey comb, cracks etc. in the R.C.C. slabs). NOTE: cement consumption 25 kg/sq.m.
72Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of toilets consisting of following operations: (a) Applying a slurry coat of neat cement cement admixed with water proofing compound conforming toIS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto UPTOFloor level height including cleaning the surface before treatment. (b) Laying Laterite Boulders with mortar using brokenBoulders150 mm to 200mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto UPTOFloor level height including rounding of junctions of walls and slabs (c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming toIS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :
73Providing and applying on a well prepared vertical surface Sonoshield HLM 5000 of BASF makeorequivalentone-component,moisture-curing, bitumen-modified polyurethane elastomeric waterproofing membrane for exterior below-grade or between-slab applications. Theproductshallbeappliedin minimum two coats to achieve total DFT of 1.25 mm. The materials shall be mixed and applied fully in accordance with the manufacturer"s instructions. This material has got very high Elongation Almost >600%. All scaffolding, ladders, supporting materials etc. complete. Rates shall be inclusive of all labour, materials, tools and plant etc. complete.
74H – PLASTERING AND FINISHING WORKS
75Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
7612mm cement plaster 1:3 (1 cement : 3 fine sand)
776mm cement plaster to ceiling 1: 3 (1 cement : 3 fine sand)
7818mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge.
79Extra for providing and mixing water proofing material proportion recommended by the manufacturers.
80Painting three or more coats with acrylic exterior paint of approved brand and manufacture (such as weather shield, APEX) including applying one coat of cement primer and one coat of surface treatment etc. complete.
81Wall painting (two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade.
82Painting (two or more coats) with epoxy paintof approved brand and manufacture in all shade on new workand under coat of suitable shade with epoxy primer of approved brand and manufacture to give an even shade
8318mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand)
8418mm thick groove cutting in cement mortar 1:4 (1 cement : 4 fine sand) cm per meter
85Providing and laying reinforced ,dowel jointed , Jointed reinforced cement concrete pavement (JRCC ) over a prepared sub base with minimum concrete grade M 30 and guaranteed flexible strength greater then 30 Kg/cm2 with 43 grade cement , course and fine aggregate confirming toIS 383 maximum size of course aggregate not exceeding 25 mm .mixed in a design, transported at site of work , laid by pumping , spread , compacted by needle and surface vibrator and finishing in continiousopretion. The rate includes cost of sealant primer ,de bounding strip , plain dowel bars, sleeves , tie rod,, admixture as approved , curing , finishing to lines and grades as per specification and drawing
86Vaccum dewatering of laid concrete for roads/ areas using Tremix machinery including formwork with MS channel/ angle sections on sides of concrete with proper supporting system, surface/screed & needle vibrating & levelling of concrete. Vaccum dewatering should be done using suction mats (spread on surface) &suction pump, power floating/ troweling using screen floater, manual spreading of hardening compound (if any), smooth/rough/broom finish to the required slope, camber & level, groove cutting (upto 10mm wide x50mm deep) for contraction/expansion, construction & longitudinal joints, Providing dowel bars with sleeve/tie bars, filling two component polysuphide sealant/joint filler (Bitumen hot sealing compound: Grade A), taping with masking tape etc complete. (Concrete, steel reinforcement, tarpaulin sheet to be paid separately)
87Providing of minimun 100mm thick factory made Shot blasted cement Interlocking paver blocks of minimum M40 grade of approved size and design/ shape lain in 50mm thick compacted bed of coarse sand, filling the joints with coarse sand etc. all completed as per the direction of Engineer . In
88Size: 200m x 100mm x 100mm (Type: Rectangular Type)
89Gray
90Other Colours
91Providing and laying 100 micron thick polythene sheets over prepared bed before placing reinforcement for concrete.
92Precast cement concrete kerb-stones (factory made) of M20 with 20 mm nominal size granitic / basaltic aggregate properly consolidated by mechanical platform and vibrators with smooth finish including fixing at site complete as per specification. - Size 60 cms L *45 cms H *15 cms T
93Supplying and fixing of cautionary/warning sign boards with reflective tape fixed on M.S. angles, tees as per drawing confirming to IRC-67-1977 etc. complete.
94Providing and fixing information boards of size (1.5x1.00)m consisting of angle iron post of (75x75x6mm) fixed in cement concrete M15 grade(45x45x60)cm ,60 cm below ground two supporting 1.5 m length of ISA (30x30x5mm) and mild steel plate of (1.5x1.0)m,3mm thick fixed to the angles by welding/bolting etc. including painting with synthetic enamel paint two coats of approved brand and shade over single coat of primer,including lettering transportation etc. complete.
95Supplying and fixing of Factory made Precast RCC slabs at site in concrete Grade of M-25 with 20 mm nominal size Granitic or basaltic aggregate, consolidated by means of mechanical platform, vibration etc. with lifting hooks of M.s. 10mm bars and PVC cups including cost of reinforcement, Certificate from manufacturer shall be produced indicating grade of concrete and minimum content of steel in the product along with 5 year free replacement warranty in case of breakagecomplete and as directed by Engineer -in -charge.
96Size 900 x 400 x 150 mm with steel reinforcement not less than 7 kg per unit -30 T capacity.
97J- TOTALWATER SUPPLY SEWERAGE, PLUMBING & SANITATION WORK
98Providing and fixing white vitreous china water closet squatting pan (Indian type w.c. pan) size 580 mm with 100 mmsand cast iron P. or S trap 10 litres high level P.V.C. flushing cister (of approved make) with fittings, rack bolts 32 mm diameter P.V.C telescopic flush pipe with fit tings and clamps 25mm P.V.C. over flow pipe withspecials & mosquito proof coupling of approved municipal design and nylon pull complete cutting and making good the walls and floors where required.
99A) Orissa pattern W.C. pan
100Proving and fixing white vitreous china water closet squating (European type w.c. pan) with seat and lid, C.P. brass hinges and rubber buffers 10 lts. High level P.V.C..Flushing cistern (of approved make) with fittings, rack bolts 32 mm diameter P.V.C.Telescopic flush pipe with fit tings and clamps 25mm P.V.C... over flow pipe withspecials & mosquito proof coupling of approved municipal design and nylon. chain and pull complete, cutting and making good the walls and floors where required.
101W.C. pan with white plastic seat and lid.
102Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430 x 260 x 350 mmand 340 x 430 x 265 mm sizes respectively with PVC automatic flushing cistern with fittings, R.S. or C.I. brackets, standard size galvanized steel flush pipe and spreaders with brass unions & G.I. clamps complete, including painting of cistern and fittings, cutting and making good the walls and floors where required.One urinal basin with 5 litres p .v .c. automatic flushing cistern.
103Providing and fixing vitreous china wash basin with RS or C.I. brackets painted white, 15 mm C.P. brass pillar taps C.P. brass chain with rubber plug 32 mm C.P. brass waste of pattern, 32 mm diameter M.I. or C.P. brass trap and union complete, including cutting and making good the walls where required. (b-Flat back wash basin size 630x 450mm with a single 15 mm C.P. brass pillar taps.)
104Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleats with C. P. brass screws and washers.
105Providing & fixing CP brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C. P. brass screws
106a)750 x 20 mm size
107Providing and fixing toilet paper holder :
108a)C.P. brass
109Providing & fixing liquid soap container with C. P. brass lid and brackets fixed to wooden cleats with C. P. brass screws
110b)Plastic container
111Fixingwater meter & stop cock in G. I. Pipe line including cutting & treading the pipe and making long screw etc. complete (cost of water meter and stop cock to be paid separately)
112Providing and fixing brass stop cock (heavy) of approved quality :
113b)20 mm nominal bore
114Providing and fixing brass full way valve(heavy) duty with wheelof approved quality :
115b)20 mm nominal bore
116c)25 mm nominal bore
117e)40 mm nominal bore
118f)50 mm nominal bore .
119Providing and fixing ballvalve(brass)ofapproved quality :
120a)High pressure with P.V.C. floats:
1213)25mm nominal bore
122Supplying and installation of HDPE water tanks Sintex / Fusion / Polycon make of 5000 litre capacity including 300 mm high brick masonry pedestal of 230mm thickin CM 1:5, providing 75mm thick RCC 1:2:4 slab with reinforcement 8mm tor @150mm c/c,lifting the tank , making all necessary GI/PVC connections to inlet, outlet, and overflow nozzles and cleaning the tank before commissioning.
123Constructing brick masonry manhole or inspection chamber with second class bricks in cement mortar 1:5 (1 cement :5 fine sand) R.C.C. top slab with 1:2:4 mix (1 cement: 2 coarse sand ;4 graded stone aggregate 20mm nominal size foundation concrete 1:2:4 mix (1 cement ;2 coarse sand :4 graded stone aggregate 40mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) neatly finished complete as per standard design.
124b)Inside size 90 x80 cm and 60 cm deep includingC.I. cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 kg. (weight of cover 23 kg.)
125Inside size 60 x 60cm and 60cm deep including C.I. cover with frame (light duty) 455x610mm internal diameter total weight of cover and frame to be not less than 38 kg. (weight of cover 23 kg).
126Making soak pit. 2.5 m dia 3 m deep with 45x45 cm dry brick honey comb shaft and S.W. drain pipe 100 mm diameter, 1.8 m long complete filled with laterite stone aggregate 125 to 180 mm surrounded by laterite stone aggregate of 40 mm and down gauge as per standard design.
127Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes ofapproved including lubricant etc. complete (single/double) socketed:
128a)110 mm dia
129b)75 mm dia
130Providing and fixing rigid PVC bend (approved make ) for S.W.R. pipes including lubricating etc complete bend withdoor :
131a)110 mm dia
132b)75 mm dia
133Providing and fixing rigid PVCbend of required degree (of approved make) for S.W.R. drainage pipes ofapproved including lubricating.
134110 mm dia
13575 mm dia
136Providing and fixing single tee of rigid PVC (approved make) for S.W.R. pipes including lubricatingetc. complete, without door:
137a)110 mm dia.
138b)75 mm dia.
139Providing and fixing single Tee of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, with door :
140a)110 mm dia
141b)75 mm dia
142Providing and fixing single “Y” of rigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, with door :
143a)110 mm dia
144b)75 mm dia
145Providing and fixing nahani trap ofrigid PVC (approved make) for S.W.R. pipes including lubricating etc complete, without door (110 mm dia)
146Providing and fixing NICKEL chrome plated copper alloy Fancy Pillar Cock rocket type Jaquar make or equivalent. Confirming to IS 8931;1993
14715mm nominal bore
148Providing and fixing NICKEL chrome plated copper alloy Fancy BIB Cock Short Body Jaquar make or equivalent. Confirming to IS 8931;1993
14915mm nominal bore
150Providing and fixing NICKEL chrome plated copper alloy Fancy Health Fouset 1.5M FLEXIBLE TUBE WITH SWINGING WALL HOOK Jaquar make or equivalent. Confirming to IS 8931;1993
151Providing and fixing R.P.V.C. vent cowl:
15275 mm dia
153Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 m. spacing.This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Internal work exposed on wall (Medium duty SDR 13.5 pipe).
15415 mm outer dia CPVC pipe
15520 mm outer dia CPVC pipe
15625 mm outer dia CPVC pipe
15732 mm outer dia CPVC pipe
15840 mm outer dia CPVC pipe
15950 mm outer dia CPVC pipe
160Providing & fixing G.I. pipes complete with G.I. fittings including trenching & re-filling etc. (external work).
16150 mm nominal bore
162Makingconnection of G. I. Distribution branch with G. I. Main 50 mm to 80 mmnominal bore by providing and fixing tee including treading the pipe etc. complete
163Providing ,installing,& commisioning of horizontal monobloc pumps 1W+1S each having discharge of 8 lps@39 mtrs.head to be fixed in line with UGT (floodedsuction)Pumps:- MOC -both moving & the materials coming in contact with water should be SS-304 & the closed coupled TEFC motor of 2900 rpm/3ph/50Htz shall be of either aluminium diecast or C.I.Supply shall be complete with 1 no solenoid valve of 1" dia for all OHT"s with it"s control panels.It shall be inclusive of 1 no control panel for 2 pumps in M.S fabricated & powder coated enclosure,comprising SPP/ACR/AM/VMO/AMSS/Phase indication lamps & alarms etc.& dry run protection to take signal from solenoid based control panel & indicate the pump to cut in & cut off depending on the level of water in the OHT,costing should includearmoured 2.5 mm/ sq. 4 core cable of length 350 mtrs.length.complete as per direction of Engineer-in-charge.
164K -MISCELLANEOUS WORK
165Providing anti – termite treatment to buildings conforming to I.S.S. 6113 part II 1971 (revised) including adoptingprecautions for health hazards and safety measures as required therein with the cost of all materials, chemicals, plants, equipments required for the treatment and furnishing a guarantee for a minimum period of 10 years from the date of completion including eradicatingany infestation of termite free of cost during the guaranty period complete. (The payment will be made on plinth of the building. ((a) Pre-construction)
166Core cuttingRCC slabs beams etc. including all scaffolding aggangement, leader,where ever required. The location of coring to be scanned by metal detector before corring and brought to the notice of engineer incharge. The coring over reinforcement shall be strictly avoided.
167110 mm outer dia.
16875 mm outer dia.
16950 mm dia outer dia.
170Anchoring Reinforcement bars of the size specified below with drilling holes of required dia and depth as specified by Hilti Re-500 and anchoring rebar including the cost of Hilti Re-500 material as specified by the manufacturer.The cost of Rebar will be paied separatly.
1718 mm dia
17210 mm dia
17312mm dia
17416mm Dia
175Providing and placingsleeves in Masonry, Concrete etc with the 6kgf/sq Cm. PVC pipe at the required location.
17650 mm dia
177100 mm Dia
178150 mm Dia
179Laying and fixing with collars light duty non-pressure NP 2 class R.C.C. pipes with cement mortar in proportion 1:2 (1 cement : 2 fine sand) in joints including cost of jointing material etc. complete.
180400mm Dia
181Providing and FixingPVC water seal in construction joints as per design and drawing shall withstand a pressureto the tune of 5 kg /cm2 op approved , make and quality confirming to relevant IS code and shall be of a single piece. Jointing of small pieces shall be strictly avoided. The nominal width shall not be less then 305mm and the thickness shall be 9mm to 12mm and shall widthstand a minimum hydro static pressure of 30m of water. The cost includes the cost of all materials , manpower, tools and plants required in the operation, and including incdents involed as per the specification, drawings and directives of Engineer in charge.
182Providing and Fixing Partition in with 12, mm fibre cement boards with approverd brand and quality over MS frame work as per design. The rate includes the cost of SS 304 grade Screws, sealing joints with approved sealent, taping the joint as per drawing and the directions of Engineer incarge. the cost of ms frame work will be paid saperatly.
183L- FIRE FIGHTING SYSTEM
184Pumps and other accessories
185Supplying and installing, testing, perfect aligning and proper leveling and commissioning of fire service main pump, of 1620 LPM (Litres/min.) at 50 m head centrifugal type single stage pump, suitable HP,as per technical specification.
186Supplying and installing, testing, perfect aligning and proper levelling and commissioning ofDiesel operated fire service stand by pump, of 1620 LPM, at 50m head centrifugal type single stage pump, suitable HP including all accessories like 200 lit fuel tank, 12 Volts 21Ah battery, exaust pipe of 3M length with silencer, suitable foundation, as per IS Specification & Engineers Instructionetc complete
187Supplying, Installation, Testing and Commissioning of Jockey pump of 180 LPM at 50 mts head, three phase,440 A.C, suitable HP Suction / Delivery Size 50/32 mm as per specification.
188Supplying and installing cast iron foot valve of size 100 mm dia with strainer for negative suction as per specification.
189Supplying and installing cast iron foot valve of size 80 mm dia with strainer for negative suction as per specification.
190Supplying and erecting double flange NRV of size 100 mm dia as per specification No. FF-VL/NRV
191Supplying and erecting isolation valve of size 100 mm dia as per specification No.
192Supplying and installing pressure gauge of 100 mm dia., 0-300 PSI or 0-14 kg/sq.cm fitted with 12/15 mm dia. pad cock valve, and G.I. pipe, elbow, etc. complete as per specification No FF - FFA/PG
193Supplying and installing pressure switch with 12/15 mm dia. Isolation valve, G.I. nipple, elbow, etc. complete As per specification No.FF- FFA /PS
194Yard hydrant Landing valve, Hose Box, etc.
195Supplying and erecting gun metal single outlet hydrant valve fitted with necessary accessories complete as per specification No.FF- VL/HV
196Supplying fire fighting R.R.L. Hose pipe 63 mm dia, 15m in length, fitted with necessary accessories complete as per specification no FF- FFA / RRL
197Supply, installation, testing and commissioning of double door Hose Box made of M.S of size 750 x 400 x 400 mm to accommodate 2 hoses of 15m length and 1 branch pipe with viewing glass on the doorsand duly painted with the letters "FIRE".
198Supply, installation , testing and commissioning of Two way Breaching inlet valve with male instantaneous inlet with cap & chain with 100 mm Butterfy Valve.
199Supplying and erecting fire brigade header of 150 mm dia for suppling water in fire tank complete as per specification no FF-FA/FBC
200Supplying and installing Air Vessel of 300 mm Ø 1.5 m. in height M.S. tank installed inside pump house as per specification.
201Supplying & errecting 20/25mm GM air release cock, with necessary GI coupling to be fitted on to of air vessel or on wet riser as per specification.
202Supplying and installing wall mounting swinging Hose reel drum fitted with 19 mm dia. 30 m high pressure polypropylene (Polyhose) long fitted with necessary accessories complete as per specification.
203External piping , underground for courtyard hydrant
204Supplying and installing G.I. pipeof "C class ERW Confirming to class 1239.Painted with anti corrosion primer paint in 2 coat and final paint.
205100 NB
20680 NB
207Electrical works
208Supplying and erecting PVC armoured cable 2 core 1.5 sq.mm.copper conductor complete erected on wall / ceiling as per specification No.CB-LT/CU
209Supplying, erecting and terminating PVC armoured cable 3 1/2 core 70 sq.mm. Aluminium conductor with continous 12 SWG G.I. earth wire complete erected with glands and lugs on wall/trusses/pole/or laid in provided trench/pipe as per specification
210Supplying, erecting and terminating PVC armoured cable 4 core 25 sq.mm. Copper conductor with continous 12 SWG G.I. earth wire complete erected with glands and lugs on wall/trusses/pole/or laid in provided trench/pipe as per specification No. CB-LT/CU
211Supplying, erecting and terminating PVC armoured cable 4 core 50 sq.mm. Copper conductor with continous 12 SWG G.I. earth wire complete erected with glands and lugs on wall/trusses/pole/or laid in provided trench/pipe as per specification No. CB-LT/CU
212Supplying, erecting and terminating PVC armoured cable 4 core 6 sq.mm. Copper conductor with continous 12 SWG G.I. earth wire complete erected with glands and lugs on wall/trusses/pole/or laid in provided trench/pipe as per specification No. CB-LT/CU
213Supplying and erecting GI stripof required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification No EA-EP.
214Supplying and erecting Annealed bare copper wireof high purity of different sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws in an approved manner.
215Fire Detection System
216Supplying, erecting,testing and commissioningManual Call Point (Pill box) with break glass push button in metal enclosure complete.
217Supply and erecting sounder hooterwith I/P voltage 24 V AC, sound power 90 Db, with 4 kw speaker housed in a factory made ABS housing
218Supply, installation,Programming & commissioning of single loopAddresable type Fire Alarm Panel 230V AC, standby battery & battery charger Provision To Connectdetectors like smoke detectors , Heat Detectors Withstd. facilities.
219supplying & installing, testing & commisioning of addressabletype multi sensor Smoke / Heat/ Gas detector .
220Fire Extinguishers
221Supplying and erecting ABC powder fire extinguisher as per IS : 13849/15683 of 6 kg capacity with necessary clamp for erection on wall.
222Supply and erecting Carbon Dioxide ( Co2 ) fire extinguisher of 4.5 kg.Capacity cartridge type conf.To IS 2878 complete erected with necessary clamp made front 50 x 6 mm.MS flat with nut and bolts grouted in wall complete.
223Passive Fire protection
224Supply installation, testing and commissioning of tube trace system for the LT panel of size given by the Project In Charge. The system shall comprise of suitable gas, tubing , control panel, necessary detection system to detect the fire in the panel and arragement to supports the same. The system shall be FM/UL listed.
225Signages
226Providing & Fixing Self luminating signages for following items of (size 4" x 12")
227Exit Signage
228Fire extinguisher Signage
229Hose Signage
230Assembly Point Signage
231Fire Alarm Signage
232Emergency Escape Plan Signage
233Signages to be installed near Electrical Panel Room etc.
234Supplying & erecting end pole D. P. Structure for 11/0.415 kV, 100 kVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 200 Amps as incomer & 6 Nos.100 Amps kitkat/MCCB for outgoing circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos. Top channel of size 100 mm x 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 x mm for erecting Transformer. Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 124 Kg. iron work ) with necessary clamps, Nut-bolts. vee cross arm, top clip, insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete.
235Supplying, installing, testing & commissioning of 3 phase, 11/0.433 kV, 50 Hz., 100 kVA, oil immersed and naturally cooled outdoor type, copper wound transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40oC by thermometer in oil and 45oC by the resistance in winding at full load rating, with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5%, with standard accessories complete with test certificate with losses below 475 Watts at 50% load, 1650 Watts at 100% load as per IS:1180 - 2014 energy efficiency level II, with necessary permissions of Electrical Inspector, as per specification no SS- TR.
236DG
237Supplying, erecting and commissioning of diesel generating set with alternator of 25 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / liquid cooled multicylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, selfexcited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level upto 75 dB at 1.0 m, provided with first filling of oil, diesel etc. as per specification no. GEN-DG
238PANELS (OUTDOOR)
239Supply, Installation, Testing and Commissioning ofElectrical Panel cubicle type, totally enclosed, free standing type, dust, damp and vermin proof,outdoor type with IP 65 protection, made up of 14/16 SWG CRCA sheet, having chemical surface treatment and finishing shall be of 2-coats of synthetic enamel, RAL - 7032, complete with copper/Al busbars, danger notice plate, interconnections with suitable capacity copper leads/solid copper strips,and having incoming and outgoing switchgears with cable alley as mentioned below and complete as per technical specifications and as required. The size of cable alley shall be sufficient enough to accomodate the cable sizes as mentioned in the SLD/ specifications/ drawings etc. and along with the following. N.B. : 1) Panel to have sealing arrangement as per GEB norms. 2) Panel desciption to be read in conjunction with the Single line diagram (SLD).
240FEEDER PILLAR
241Feeder Pillar consisting of :
2421) Incomers: MCCB , TP, 250 A, 36KA Thermal release - 1 No. 2) Indications & Metering: i) RYB LED Indicating lamps and voltmeter (0-500V) backed up by 3 Nos. ofMCB, SP, 2A MCB . ii) Ammeter-(0-250A) including CTs - 250/5A , 10VA burden, class 1.0 - 3 Nos. Busbar: 320 A TPN Al.Busbar. Outgoings: i) MCCB, FP, 100A, 415 volts, 25KA with Thermal magnetic release, spreader links,phase barriers, rotary handle-2 nos. ii) MCCB, FP, 63A, 415 volts, 25KA with Thermal magnetic release, spreader links,phase barriers, rotary handle-1 no. iii) MCB, TP, 40A, 415V, 10KA-3 nos.
243Supply,Installation,Testing & Commissioning all complete
244PANELS (INDOOR)
245Supply, Installation, Testing and Commissioning ofElectrical Panel cubicle type, totally enclosed, free standing type, dust, damp and vermin proof,indoor type with IP 56 protection, made up of 14/16 SWG CRCA sheet, having chemical surface treatment and finishing shall be of 2-coats of synthetic enamel, RAL - 7032, complete with copper/Al busbars, danger notice plate, interconnections with suitable capacity copper leads/solid copper strips,and having incoming and outgoing switchgears with cable alley as mentioned below and complete as per technical specifications and as required. The size of cable alley shall be sufficient enough to accomodate the cable sizes as mentioned in the SLD/ specifications/ drawings etc. and along with the following.
246COMMON METER & BUSBAR PANEL (FOR GROUND FLOOR)
247Panel consisting of: Incomer:
248ii) MCCB, TP, 63A, 415 volts, 25KA with Thermal magnetic release, spreader links,phase barriers, rotary handle-1 no. Busbar: 320 A TPN Al.Busbar. Outgoings: Outgoing MCBs to be provide inside the compartment but not accessible for regular operation. MCB, SP, 20A, 230V, 10KA-7 nos. MCB , TP, 63 A, 10KA- 1 No. MRT tested direct 10-60A KWH meter- 1 no. Compartment shall have sealing arrangement as shown in SLD 5) Motor Operated Switch (MOS): Comprising of MOS, 4P, 63Aalong with associated control circuitry with LVM to sense quality of available GEB supply and make suitable automatic changeoverto Mains/DG. And stay at OFF position if good power from either side (Mains & DG) is not avaiable. Compartment shall have visual indication of Load on Mains / DG or OFF depending of the status of ATS. ATS shall also have manual facility to selectively turn to desiredposition by handle. Outgoings requiring DG Backup: MCB, DP, 16A, 230V, 10KA-3 nos. MCB, DP, 20A, 230V, 10KA-1 no. MCB, TP, 25A, 415V, 10KA-1 no. MCB, TP, 32A, 415V, 10KA-1 no. MCB, FP, 40A, 415V, 10KA-1 no. N.B. : 1) Panel to have sealing arrangement as per GEB norms. 2) Panel desciption to be read in conjunction with the Single line diagram (SLD).
249Supply,Installation,Testing & Commissioning all complete
250LT CABLES
251Supply of3 1/2 core armoured PVC insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.
2523 1/2 Core 25 sq.mm
2533 1/2 Core 70 sq.mm
254Supply of4 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.
2554 Core 16 sq.mm
256Supply of4 core armoured PVC/XLPE insulated, PVC sheathed copper conductor cable of 1.1 KV grade with ISI markconforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size.
2574 Core 2.5 sq.mm
258Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required.
259(b) In rocky Strata
260Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required.
261(b) In rocky strata
262Laying of one number additional PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground in the same trench in one tier horizontal formation including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required.
263(b) In rocky strata
264Laying of one number additional PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground in the same trench in one tier horizontal formaion including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Incharge,sand cushioning with screened sand bed of 20mm thick , protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required.
265(b) In rocky strata
266Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface,etc.complete as required
267Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.
268(1) 4 x 1.5/2.5 Sq. mm.
269Supplying and making cable end terminations with brass compression gland and copper lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.
270(2) 3 1/2x 25 Sq. mm.
271(3) 3 1/2x 70 Sq. mm.
272Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.
2734 x 16 Sq. mm.
274CABLE TRAYS
275Supplying and Installing following size perforatedtype 16 SWG, M.S.cable tray of GI pregalvanised/hot dip galvanised/ powder coated finish, in convenient sections, joined with connectors, suspended from the ceiling with suitable MS suspenders including bolts and nuts, painting suspenders etc, complete as required.
276300mm width x 50mm depth
277DBs, MCBs, RCCBs etc.
278Supplying and fixing following way SPN sheet steel MCB distribution board 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted ncluding earthing etc. as required ( but without MCB/RCCB/Isolator)
2798 way double door Cat A
280Supplying and fixing 6 A to 32 A,C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.
281SP, Cat A
282DP,Cat A
283Copper wiring in PVC Conduit
284Supplying and fixing of following sizes ofrigid PVC conduit alongwith accessories in surface(medium)/recess(heavy) includingcutting the wall and making good the same in case of recessed conduit as required.
285(a) 20 mm
286Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required.
287(b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit)
288Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) with modular switch, modular plates,suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
289(f) Group C-- with Cat B Modular Accessories
290Wiring for group controlled light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy)and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
291Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) with 2 way modular switch, modular plates,suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
292(b) with Cat B Modular accessories
293METAL BOXES, SOCKETS, FAN REGULATORS
294Supplying and fixing 3 pin 5 A ceiling rose on the existing junction box/ wooden block including connections etc as required.
295Supplying and fixing stepped type electronic fan regulator on the existing modularplate switch box including connections but excluding modular plate etc. as required (Cat B)
296(b) Cat B
297Supply and erecting fan hook box ( 100 mm diameter or equivalent square size, 75mm deep) fabricated out of 16 SWG sheet steel with 10 m round bar hook bounded to RCC steel upto 50 mm length protruding on each side of the box, including painting with 2 coats of red oxide, complete as required
298FITTINGS,FANS,Acs
299INTERNAL
300Supplying and erecting LED square / circular 9 to 12W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
301Supplying & erecting LED 2 X 20W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete.
302Supply and erecting of 48 inch ( 1200mm sweep) ceiling fan, double ball bearing type, , complete with all accessories.
303(a) Cat A
304Supplying and erecting ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
305Supply and erecting of 9 inch (225 mm sweep) exhaust fan with double ball bearings, 1400 rpm, complete with all accessories.
306(a) Cat A
307ENERGY METERS
308Supply and erecting meter box suitable for single phase energy meter and incoming SP/DP MCB, fabricated out of 16 SWG sheet steel, powder coated, complete as required and conforming to the requirements of Goa Electricity Deaprtment.
309Supply, installation, testing and commissioning of electronic type single phase energy meter (KWh), ISI marked, in polycarbonate or sgheet steel body ( base mounting type) with counter display/LCD display, with ELT, in Class 1.0, 50 Hz, 240 V. AC duly tested by MRT along with Test Certificates, complete as required of following capacity of make L & T only.
310(b) 10 to 40 A
311EARTHING
312Supply and providingChemical earthing system (Pipe in pipe type)withOuter pipe of the electrode having minimum 80mm diameter as per the enclosed specifiations and drawing.The outer and the inner hot dip galvanised MS pipes shall conform to the specifications and the space inbetween shall be filled withhighly crystalline conductiveand anti- corrosive mixture conforming to IS-3043. The earth electrode shall be CPRI tested.The scope of work includes boring (300mm dia minimum)/excavation of soil/hard rock, refilling with required quantity of back fill compound/Ground resistance enhancement powder of requisite quantity, compaction, constuction of masonary chamber etc complete as required to obtain the desired value. Aluminium tag with embossed earthing value shall be permanently attached to the pipe electrode
313(a) 3 metres length electrode
314Earthing with GI earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with CI/RCC coverhaving locking/Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation ofpit of size 1.0x1.0x 3.0 mtrs(min) and disposal of excavated soil.c)Watering GI pipe, 20mm, Class B,with funnel as per specs. d)Charcoal/salt as per specs ( paid seperately). e) Refilling the pit of size 1.0x1.0x 3.0 mtrs(min) with soft black agriculture soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe.g)watering arrangement(plumbing will be paid seperately).
315In rocky strata
316Extra for using salt and charcoal for GI or copper plate earth electrode as required( 96 Kgs of Charcoal and 5 Kgs of Salt)
317Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
318Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail