Tender For Repair To Ac Sheet Roofing With Cgi Pgi Sheets, Roof Treatment And Connected Items To Otm Md Accn At Kaluchak Mil Stn Under Ge Kalucha, kaluchak-Jammu And Kashmir

Military Engineer Services-MES has published Tender For Repair To Ac Sheet Roofing With Cgi Pgi Sheets, Roof Treatment And Connected Items To Otm Md Accn At Kaluchak Mil Stn Under Ge Kalucha. Submission Date for this Tender is 13-01-2023. Shed Construction Tenders in kaluchak Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

35316063
Corrigendum : Tender For Repair To Ac Sheet Roofing With Cgi Pgi Sheets, Roof Treatment And Connected Items To Otm Md Accn At Kaluchak Mil Stn Under Ge Kalucha
Open Tender
Indian
Jammu And Kashmir
kaluchak
13-01-2023

Tender Details

Repair To Ac Sheet Roofing With Cgi Pgi Sheets, Roof Treatment And Connected Items To Otm Md Accn At Kaluchak Mil Stn Under Ge Kalucha

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Dec-2022 Other amendment Other 06-01-2023
2 22-Dec-2022 Revision of BOQ BOQ 06-01-2023
3 06-Jan-2023 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 13-01-2023

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-

BOQ Items

Name of Work: REPAIR TO AC SHEET ROOFING WITH CGI/PGI SHEETS, ROOF TREATMENT AND CONNECTED ITEMS TO OTM/MD ACCN AT KALUCHAK MIL STN UNDER GE KALUCHAK
Sl. No. Item Description
1Dismantling asbestos cement (corrugated, semi corrugated etc.) sheets in roof coverings, complete all as specified & directed.
2Dismantling plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof covering, complete all as specified & directed.
3Dismantling plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof covering, complete all as specified & directed.
4Rolled mild steel work in roof trusses (framed) trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., conforming to Fe-290 grade-E-165, complete all as specified & directed.
5Dismantling timber scantling as in fillets, rails, purlins, etc under 40 sq cm in section, in any position, in unframed work, complete all as specified & directed.
6Dismantling timber scantling 40 Sqcm and over in section, in any position (framed work), complete all as specified & directed.
72nd class hard wood (Sal/Hollock) as in scantling, clean sawn timber, fixed in framed work, complete all as specified & directed.
8Pre-painted galvalume aluminum zinc coating GI based profile steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified & directed.
9Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in as in ridges, hips, valley gutters, drip and straight flashings, fixed with self tapping screws, complete all as specified & directed.
106mm thick asbestos cement, corrugated or semi-corrugated sheeting in roof, walls etc., fixed with L-type or J-type or cranked hook bolts, complete all as specified & directed.
11Asbestos cement two piece adjustable serrated ridge for corrugated or semi corrugated sheets 6mm thick fixed with L-type or J-type or cranked hook bolts, complete all as specified & directed.
122mm thick fibre glass reinforced translucent corrugated sheeting with two corrugation side lap, fixed with self taping screws, complete all as specified & directed.
13Dismantling wall & ceiling board (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified & directed.
14Suspended false ceiling system using 4mm thick high pressure steam cured fibre cement pre-primed textured varient E-board (classic), ISI marked, conforming to IS:14982-2000 over and including GI snap grid frame workfor false ceiling, grid size605 x 605 mm with GI angle of size 24x24mm, main runner ‘T’ of size 24x38mm, secondary runner ‘T’ of size 24x28mm with 3mm GI wire with butterfly clips as hangers for leveling, fastners, supports, plugs to walls/joists etc , hangers to be fixed with approved rawl plug, level adjusters and screwsa etc, last hanger at the end of each runner shall not be greater than 450mm from adjacent wall all as per manufacturer’s Instructions including making holes, cutting chasis and making good existing walls in cement mortar 1:3 or PCC 1:2:4 type B1, complete all as specified anddirected. Note : All steel members shall be hot dipped galvanised with zinc coating not less than 120 gm/sqm.
15Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified & directed.
16PCC 1:4:8, nominal mix, type D-2 using 40mm graded crushed stone aggregate as in foundations, filling & mass concrete, complete all as specified & directed.
17Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6, complete all as specified & directed.
18Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6 but except brick i.e. using serviceable bricks obtained from Srl item No. 15 here-in-before, complete all as specified & directed.
19Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan to any radius, half brick thick walls built in cement mortar 1:4, complete all as specified & directed.
20Demolition of reinforced cement concrete of any description in any position not otherwise specifically provided for(Reinforcement cut as required to facilitate demolition), complete all as specified & directed.
21TMT bars 10mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
22TMT bars 5mm dia & over upto & including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500, complete all as specified & directed.
23RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified & directed.
24Use & waste of form work to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc alo splays between floors and beams for rough finished surfaces of concrete, complete all as specified & directed.
25PCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified & directed.
26Taking down cement plaster on brick or stone surfaces of wall/ceiling, chajjas, roof projections etc upto triple storey etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified & directed.
27Taking down cementplaster and decayed concrete of any description,upto triple storey of building from roof projection, chajjas etc and making good the decayed portion with cement mortar 1:3 mixed with integral water proofing compound orPCC 1:2:4 type B-0 using 12.5mm graded crushed stone aggregate including necessary form work/scaffolding where ever required, rendering with 15 mm thickin cement mortar 1:3, surface finished even and smooth without using extra cementusing liquid water proofing admixture as per manufacturer,s instructions, complete all as specified & directed. Note : Liquid water proofing admixture shall be measured & paid seprately.
2815mm thick rendering in cement mortar1:4 onfair faces of brick surfaces or concrete surfaces upto triple storey of building, surface finished even and smooth without using extra cement, complete all as specified & directed.
2915mm thick rendering in cement mortar1:6 onfair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified & directed.
305mm thick rendering in cement mortar1:3 on concrete surfaces of ceiling and similar items, surface finished even and smooth without using extra cement, complete all as specified & directed.
31Preparation of new plastered or concrete surfaces of wallsand applying two coats of cement base paint over a coat of cement primer, complete all as specified & directed.
32Preparation of new plastered surfaces of wall and applying two coats of oil emulsion distemper over a coat of primer, complete all as specified.
33Preparation of new plastered surfaces of ceilingand applying three coats of white wash, complete all as specified & directed.
34Preparation of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats ofsynthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified & directed.
35Preparation of old decorated plastered or unplastered surface of walls (upto triple storey building with necessary scaffolding) including cornices, pilasters etc by brooming down or by steel wire brushes, scrapingdown smoke spots, moulds, moss and efflorescent salts, trading oil, greasy spots etc. and applying one coat of cement base paint, complete all as specified & directed.
36PVC (SWR) pipes, 75mm bore, single socketed, in any length with rubber ring joints, fixed to walls with necessary clamps, fixed in repairs,complete all as specified & directed.
37PVC (SWR) pipes, 110mm bore, single socketed, in any length with rubber ring joints, fixed to walls with necessary clamps,fixed in repairs, complete all as specified & directed.
38110mm bore PVC (SWR) bends any radius with or without oval access door, fixed in repairs, complete all as specified & directed.
39PVC (SWR) branch piece, single (single Y) equal or unequal, 110mm bore, fixed in repairs, complete all as specified & directed.
4020mm bore, ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight20mm - 210gms), fixed in repairs, complete all as specified & directed.
41PVC cover suitable for water storage tank of 500 ltrs with locking arrangements, fixed in repairs,complete all as specified & directed.
42Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for bore of pipe 20mm, fixed in repairs, complete all as specified & directed.
43Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning and removing all scale and dirt, etc from tanks and from mouths of circulating pipes by using bleaching powder, hoisting if required,reconnecting and re-fixing in position of capacity exc. 500 but n exc. 1000 ltr,making good for running of water from tank to inside of bldgs and writing of date of cleaningand due on by synthetic enamel paint on water tank, complete all as specified & directed. Note : Cost of bleaching powder shall be deemed included in the quoted rate of this item.
44Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified & directed.
45Non skid ceramic coloured tiles,7 to 8 mm thick (square/ rectangular) area of each tile exc 0.06 sqm but nexc 0.11 sqm in floor etcset & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:6, taking down door shutter and refixing the shutter at same place after laying of tile, complete all as specified and directed.
46Glazed ceramic coloured tiles of size 450mmx300mm, thickness 7mm as in vertical surfaces such as skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified & directed.
47Non skid ceramic coloured tiles,7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but nexc 0.18 sqm in floor etcset & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:6, taking down door shutter and refixing the shutter at same place after laying of tile, complete all as specified and directed.
48Non skid ceramic coloured tiles,7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but nexc 0.18 sqm as in vertical surfaces such as skirting, dado, wall etc., set and jointed in neat cement slurry and pointed with coloured cement to match over and including 10mm thick rendering in cement mortar 1:4, complete all as specified & directed.
4975mm thick PCC 1:3:6 (nominal mix), type C-2 using 40mm graded crushed stone aggregate as in sub base of floor etc, complete all as specified & directed.
50Precast designer coloured paver tiles (factory made rectified) of size 300mmx300mm x 20mm, top layer glazed made in any type of cement and pigment, in required patterns (compressive strength not less than 250 Kg per Sqcm) as approved by GE in floor etcset & jointed in neat cement slury & pointed in white or coloured cement mixed with pigment to match over and including 15mm thick screed layer in cement mortar 1:6, complete all as specified & directed.
51Taking up or down steel tubing and connections 15mm bore, complete all as specifed & directed.
52Taking up or down steel tubing and connections 20mm bore, complete all as specifed & directed.
53Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc,; and cutting chases for concealed water tubing or concealed conduit wiring etc., and making good, cutting exc. 10cm girth but not exc 20cm girth in brick/stone walls, complete all as specified & directed.
54Galvanized iron water tubing, medium grade, 15mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, completeall as specified and directed.
55Refixing old steel tubing and connections of 20mm bore in new or old position (Walls, ceiling, floors etc.) including cleaning for refixing, complete all as specified and as directed .
56Galvanized iron water tubing, medium grade, 20mm bore with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, completeall as specified and directed.
57Hacking out old broken glass (any thickness, size, quality or description) from wooden/metal frame or stone, concrete or brick surrounds, glazed with putty or fixed with beads, n exc 1.5 sqm, complete all as specified & directed.
583mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads or glazing pins in metal frame in squares not exc. 0.5 Sqm in each pane, complete all as specified & directed.
593mm thick figured glass, pin headed type and glazing with oil putty or wooden beads or glazing pins in squares not exc. 0.5 Sqm in each pane, complete all as specified & directed.
60Demolition of cement concrete (un-reinforced) of any description in any position not otherwise specifically provided for, complete all as specified & directed.
6150mm thick PCC 1:3:6, nominal mix, type C1, using 20mm graded crushed stone aggregate as in plinth protection, surface finished even and smooth without using extra cement including filling of 6mm thick jointswith bitumen mastic filling comprising of one part of heated bitumen 85/25 or 80/100 grade and three part of sand by weight, laid in a stretch not exc 3m and joint at every turning/corners complete all as specified & directed.
62Complete removal of the existing roof treatment of any description viz tarfelt or membrance surface of roof tiles/concrete padding etc including grubbing up of tree roots, removing existing water tank of any capacity, refixing at same place after making necessary arrangements, removing all the debris to a distance n exc 100m for roof treatment work, preparation of the concrete roof surfaces by scrubbing down with steel brushes and cleaning with water all loose dirt/dust and applying the following Roof Treatment complete all as specified & directed :- (a) Applying 1st course of 15mm thick screed bed in cement mortar 1:4 over concrete surfaces. (b)Applying 2nd course of bitumenous primer conforming to IS-3384 @ 0.4 Kg/Sqm over the screed bed. (c) Applying 3rd coarse of a coat of blown type bitumen of grade 85/25 heating to a working temperature of 180° C and applied @ 1.2 Kg/Sqm.
63(d) Applying 4th course of APP (Atactic Polypropylene) modified polymeric membrane 3 mm thick weight not less than 3.6 Kg/Sqm with 160 Grams/Sqm non woven polyster made at centre core reinforced laid with 75 mm side overlap and 100 mm overlap. The membrane has to be laid with LPG torch and overlap sealed and finished neat. (e) Applying 5th course of a coat of bonding materialwithblown type bitumen of grade 85/25 heating to aworking temperature of 180° C and applied @ 1.2 Kg/Sqm.
6425mm thick PCC 1:2:4, nominal mix, type B-0, using 12.5mm graded crushed stone aggregate as in roof padding and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified & directed.
65Chequered cement concrete tiles, machine pressed, factory made of size 25cmx25cm, 20mm thick, with grey cement and no pigment, set, jointed and pointed in neat cement slurry, laidover roof treatment surface, over and including 15mm thick screed layer in cement mortar 1:6, complete all as specified & directed.
66Preparation of new treated surfaces of roof and similar items and applying one coat of bitumenious based aluminium paint, complete all as specified & directed.
67PVC (SWR) pipes, 110mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors, fixed in repairs, complete all as specified & directed.
68PVC (SWR)junction single(Single T) equal or unequal, 110mm bore with oval access door, fixed in repairs,complete all as specified & directed.
69PVC (SWR) vent cowl of size 110mm bore, complete all as specified & directed.
7075mm bore PVC (SWR) bends any radius with or without oval access door, fixed in repairs, complete all as specified & directed.
71PVC (SWR)junction single(Single T) equal or unequal, 75mm bore with oval access door, fixed in repairs,complete all as specified & directed.
72PVC (SWR) pipes, 75mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors, fixed in repairs, complete all as specified & directed.
73Vitreous chinaware squatting pan, "Orissa Pattern" size 580mm x 440mm with integral foot rests, white, with ‘P’ or ‘S’ trap, front or back inlet, including provision of lime concrete, making connections to trap and to flush pipe etc. and making good to floors, fixed in repairs, complete all as specified & directed.
74Vitreous china wash down water closet (Pedestal pattern), white with‘P’ or ‘S’ trap, plastic water closet seat, white, closed pattern with flat bottom and cover, mild steel chromium plated or aluminium hinging device, chromium plated jet nozzle with 1500mm long PVC pipe fixed with screws of suitable size includingmaking connections to trap and to flush pipe, fixing flushing cistern etc. and making good to floors, fixed in repairs, complete all as specified & directed.
75PVC connections 15mm size with PTMT nuts of length 450mm, fixed in repairs,complete all as specified & directed.
76Stop valves, 15mm bore, fancy type, chromium plated with long shank and cup (concealed type), cast copper alloy,screweddown, high pressure with crutch or butterfly handle, both ends screwed for iron pipe orfor union etc., fixed in repairs, complete all as specifed & directed.
77Stop valves, cast copper alloy, 15mm bore, screweddown, high pressure with crutch or butterfly handle, both ends screwed for iron pipe orfor union etc., fixed in repairs, complete all as specifed & directed.
78Rotationally moulded polyethylene water storage tank (cylindrical vertical with closed top), three layers, hoisted & fixed in position of capacity 500 ltrs including making connections and 20mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight20 mm - 210 gms) including dismantling of old unserviceable water tank with fittings,complete all as specified & directed.
79Rotationally moulded polyethylene water storage tank (cylindrical vertical with closed top), three layers, hoisted & fixed in position of capacity 1000 ltrs including making connections and 20mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight20 mm - 210 gms) including dismantling of old unserviceable water tank with fittings,complete all as specified & directed.
80Unplasticized PVC pipes of pressure rating 10 kgf/sq. cm, 25mm bore, jointed as per manufacturers instructions with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., fixed complete to walls and ceilings or laid in floors, completeall as specified and directed.
81Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified & directed.
82Water proofing treatment to sunken portion with 15mm thick rendering in cement mortar 1:3 using integral water prooofing compound both on floor and walls including preparation of surface by making free from all loose particles, surface cured and allowed to dry,apply a coat of Moisture Cured High Tensile Elastomeric Modified Poly Urethane based liquid membrance coatingas per manufacturers instructions both on floor as well on walls, sunken slab shall be laid to a slope of 1:40 outwards with 25mm dia PVC pipe spout projecting at least 45mm beyond out face of wall, complete all as specified & directed.
83Notes : a) PVC spout 25mm dia, PCC 1:4:8 type D2 and WC / EWC shall be measured and paid for separately under respective items. b) Ponding shall be done in sunken portion area by filling water which shall be kept there for one week. In case a slightest indication of seepage /leakage is noticed, the same shall be rectifird by grounting the effected area at no extra cost. Thereafter, ponding shallbe repeated till there is no indication of seepage/leakage. The arrangements of ponding to be included in quoted rates and nothing shall be admissible on this account.
84PVC (SWR) floor trap, plainwith grating including jointing to waste pipe with solvent cement, dia of outlet 75mm, fixed in repairs, complete all as specified & directed.
85Cleaning/ clearing of sewage line (including manholes) of 100mm to 150mm bore of any description, underground at any depth, removing any type of blockage including desilting, descaling & dechockingof drains as well as manholes with combined high pressure water jetting cum suction (vacuum) type machine mounted on LCV/ HCV and having facilities of high pressure vacuum and provision of hydraulic application through high pressure thermo plastic fibre based water jetting hose andconical round shape nozzle pipe and flushing after cleaning including removing the same in the tank to a place outside cantonment at the place meant for the purpose by local municipality, complete all as specified & directed.
86Cleaning of blocked WC including and upto first manhole manually and well flushing with clear water, making the seat functional including depositing the sludge in a pit (including digging of pit) not less than 100 meter away from site of cleaning and covering the deposited sludge with minimum 25cm thick layer of earth and spreading unslacked lime on the pit, complete all as specified & directed.
87Mild steel framed work as in water tank staging, doors or gates of angle or other section with gusset plates, rails, braces, etc., complete drilled for fixing of steel sheeting or other covering, doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing conforming to Fe-290 grade-E-165, complete all as specified & directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy