Tender For Supply Installation Testing And Commissioning Of Vrv Vrf Ac Odu 6Hp Vrv Vrf Cassette Ac Idu 2 Tr And 2Tr Hw Inverter Type With 410A Gas At Adsn Building, bangalore-Karnataka

Bharat Electronics Limited-BEL has published Tender For Supply Installation Testing And Commissioning Of Vrv Vrf Ac Odu 6Hp Vrv Vrf Cassette Ac Idu 2 Tr And 2Tr Hw Inverter Type With 410A Gas At Adsn Building. Submission Date for this Tender is 24-12-2022. Bolts Tenders in bangalore Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

35289616
Corrigendum : Tender For Supply Installation Testing And Commissioning Of Vrv Vrf Ac Odu 6Hp Vrv Vrf Cassette Ac Idu 2 Tr And 2Tr Hw Inverter Type With 410A Gas At Adsn Building
Open Tender
Indian
Karnataka
bangalore
24-12-2022

Tender Details

Supply Installation Testing And Commissioning Of Vrv Vrf Ac Odu 6Hp Vrv Vrf Cassette Ac Idu 2 Tr And 2Tr Hw Inverter Type With 410A Gas At Adsn Building Supply Installation Testing And Commissioning Of Vrv Vrf Ac Odu 6Hp Vrv Vrf Cassette Ac Idu 2 Tr And 2Tr Hw Inverter Type With 410A Gas At Adsn Building , Supply Of Variable Refrigerant Volume ( Vrv ) / Variable Refrigerant Flow ( Vrf ) Type Air Conditioning Systems Outdoor Unit Of Capacity Not Less Than 6 Hp, Equiped With Highly Efficient Hermetic Scroll Compressor Or Twin Rotary Type Compressors, Equipped With Inverter Control Capable Of Changing The Speed In Accordance To The Cooling Load Requirement, Heat Exchanger, Low Noise Condenser Fan, Outdoor Unit Multiple Connecting Unit, Including First Charge Of R410a Refrigerant & Oil, Etc. The Inverter Shall Be Igbt Type To Be Efficient And Quiet Operation. The Outdoor Unit Shall Have The Multi-Step Of Capacity Control To Meet Load Fluctuation. The Quoted Price Shall Include Ms Angle Base Frame Structure Duly Black Painted With Synthetic Epoxy Paint For All Outdoor Units. The Frame Structure Shall Be Mounted On Ms Plate & Serrated Rubber Pads All As Specified And / Or Directed Etc., Complete. Note: The Quotedrate For This Item Deemed To Include The Cost For Necessary Hardware, Software, Gateway, Interface, Controller Etc. , Supply Of Variable Refrigerant Volume ( Vrv ) / Variable Refrigerant Flow ( Vrf ) Type Air Conditioning Systems Indoor Unit Of Cassette Acof Capacity Not Less Than 2.0Tr ( 7.0 Kw ) With Cordless Remote For Individual Unit, Cooling Coil, Expansion Valve, Multi Speed Fan, Motor, Power Wiring From Nearest Power Socket To Indoor Unit Etc. The Blower Shall Be Dynamically Balanced And Designed For Silent Operation, The Drain Pan Shall Be Fabricated Out Of Heavy Sheet Steel With Insulation, Ms Brackets / Supports, All As Specified And / Or Directed Etc., Complete. , Supply Of Inverter Type Hi Wall Split Ac With 2.0Tr Capacity With R410a / R32 Refrigerant Gas, Wireless Remote Controller, Cooling Thermostat, Required Length Of Power Cable And Control Cable Between Indoor And Outdoor Units, Earthing, Supports Etc. Complete , Installation, Testing And Commissioning Of Variable Refrigerant Volume ( Vrv ) / Variable Refrigerant Flow ( Vrf ) Type Air Conditioning Systems Outdoor Unit Of Capacity Not Less Than 6 Hp, Equiped With Highly Efficient Hermetic Scroll Compressor Or Twin Rotary Type Compressors, Equipped With Inverter Control Capable Of Changing The Speed In Accordance To The Cooling Load Requirement, Heat Exchanger, Low Noise Condenser Fan, Outdoor Unit Multiple Connecting Unit, Including First Charge Of R410a Refrigerant & Oil, Etc. The Inverter Shall Be Igbt Type To Be Efficient And Quiet Operation. The Outdoor Unit Shall Have The Multi-Step Of Capacity Control To Meet Load Fluctuation. The Quoted Price Shall Include Ms Angle Base Frame Structure Duly Black Painted With Synthetic Epoxy Paint For All Outdoor Units. The Frame Structure Shall Be Mounted On Ms Plate & Serrated Rubber Pads All As Specified And / Or Directed Etc., Complete. , Installation, Testing And Commissioning Of Variable Refrigerant Volume ( Vrv ) / Variable Refrigerant Flow ( Vrf ) Type Air Conditioning Systems Indoor Unit Of Cassette Acof Capacity Not Less Than 2.0Tr ( 7.0 Kw ) With Cordless Remote For Individual Unit, Cooling Coil, Expansion Valve, Multi Speed Fan, Motor, Power Wiring From Nearest Power Socket To Indoor Unit Etc. The Blower Shall Be Dynamically Balanced And Designed For Silent Operation, The Drain Pan Shall Be Fabricated Out Of Heavy Sheet Steel With Insulation, Ms Brackets / Supports, All As Specified And / Or Directed Etc., Complete. , Supply Of Size 22.2 Mm Dia Refrigerant Grade Copper Piping Of 20 Gauge Including Nitrile Rubber Tubular Insulation, Adhesive Tape, Including All Kinds Of Valves / Joints Viz., Refnet Joint / Header, Refrigerant Joint / Header, Distribution / Branch Unit, Tees, Valves, Ball Valves, Fittings Like Bends, Elbow, Collars, Tees, Reducers, Flanges, Supports, Etc For Interconnecting The Liquid And Suction Lines Between Theoutdoor Units And The Indoor Units And Flare Connection To Indoor Units. Refrigerant Joints Supplied By Oem Only Shall Be Used. The Piping Shall Be Carried Out Of Soft / Hard Drawn Copper Pipes Brazed Socket Fittings. Both The Suction And Liquid Lines Shall Be Insulated With Closed Cell Nitrile Rubber Tubular Insulation With Factory Laminated Glass Cloth And Uv Paniting Of Thickness As Specified In Tender Including Pressure Testing And Charging Of Refrigerant And Oil. Refrigerant Piping And Cables In Wall Crossings Shall Be Provided In Suitable Steel / Pvc Sleeve All As Specified And / Or Directed Etc., Complete. Note: 1 ) Only The Cable Tray Supports Provided For Exposed Refrigerant Pipes Will Be Measured And Paid Under The Relevant Item Of Soqr. , Erection And Testing And Commissioning Of Size 22.2 Mm Dia Refrigerant Grade Copper Piping Of 20 Gauge Including Nitrile Rubber Tubular Insulation, Adhesive Tape, Including All Kinds Of Valves / Joints Viz., Refnet Joint / Header, Refrigerant Joint / Header, Distribution / Branch Unit, Tees, Valves, Ball Valves, Fittings Like Bends, Elbow, Collars, Tees, Reducers, Flanges, Supports, Etc For Interconnecting The Liquid And Suction Lines Between Theoutdoor Units And The Indoor Units And Flare Connection To Indoor Units. Refrigerant Joints Supplied By Oem Only Shall Be Used. The Piping Shall Be Carried Out Of Soft / Hard Drawn Copper Pipes Brazed Socket Fittings. Both The Suction And Liquid Lines Shall Be Insulated With Closed Cell Nitrile Rubber Tubular Insulation With Factory Laminated Glass Cloth And Uv Paniting Of Thickness As Specified In Tender Including Pressure Testing And Charging Of Refrigerant And Oil. Refrigerant Piping And Cables In Wall Crossings Shall Be Provided In Suitable Steel / Pvc Sleeve All As Specified And / Or Directed Etc., Complete. Note: 1 ) Only The Cable Tray Supports Provided For Exposed Refrigerant Pipes Will Be Measured And Paid Under The Relevant Item Of Soqr. , Supply Of Size 19.1 Mm Dia Refrigerant Grade Copper Piping Of 20 Gauge Including Nitrile Rubber Tubular Insulation, Adhesive Tape, Including All Kinds Of Valves / Joints Viz., Refnet Joint / Header, Refrigerant Joint / Header, Distribution / Branch Unit, Tees, Valves, Ball Valves, Fittings Like Bends, Elbow, Collars, Tees, Reducers, Flanges, Supports, Etc For Interconnecting The Liquid And Suction Lines Between Theoutdoor Units And The Indoor Units And Flare Connection To Indoor Units. Refrigerant Joints Supplied By Oem Only Shall Be Used. The Piping Shall Be Carried Out Of Soft / Hard Drawn Copper Pipes Brazed Socket Fittings. Both The Suction And Liquid Lines Shall Be Insulated With Closed Cell Nitrile Rubber Tubular Insulation With Factory Laminated Glass Cloth And Uv Paniting Of Thickness As Specified In Tender Including Pressure Testing And Charging Of Refrigerant And Oil. Refrigerant Piping And Cables In Wall Crossings Shall Be Provided In Suitable Steel / Pvc Sleeve All As Specified And / Or Directed Etc., Complete. Note: 1 ) Only The Cable Tray Supports Provided For Exposed Refrigerant Pipes Will Be Measured And Paid Under The Relevant Item Of Soqr. , Erection Andtesting And Commissioning Of Size 19.1 Mm Dia Refrigerant Grade Copper Piping Of 20 Gauge Including Nitrile Rubber Tubular Insulation, Adhesive Tape, Including All Kinds Of Valves / Joints Viz., Refnet Joint / Header, Refrigerant Joint / Header, Distribution / Branch Unit, Tees, Valves, Ball Valves, Fittings Like Bends, Elbow, Collars, Tees, Reducers, Flanges, Supports, Etc For Interconnecting The Liquid And Suction Lines Between Theoutdoor Units And The Indoor Units And Flare Connection To Indoor Units. Refrigerant Joints Supplied By Oem Only Shall Be Used. The Piping Shall Be Carried Out Of Soft / Hard Drawn Copper Pipes Brazed Socket Fittings. Both The Suction And Liquid Lines Shall Be Insulated With Closed Cell Nitrile Rubber Tubular Insulation With Factory Laminated Glass Cloth And Uv Paniting Of Thickness As Specified In Tender Including Pressure Testing And Charging Of Refrigerant And Oil. Refrigerant Piping And Cables In Wall Crossings Shall Be Provided In Suitable Steel / Pvc Sleeve All As Specified And / Or Directed Etc., Complete. Note: 1 ) Only The Cable Tray Supports Provided For Exposed Refrigerant Pipes Will Be Measured And Paid Under The Relevant Item Of Soqr. , Supply Of Size 15.9 Mm Dia Refrigerant Grade Copper Piping Of 20 Gauge Including Nitrile Rubber Tubular Insulation, Adhesive Tape, Including All Kinds Of Valves / Joints Viz., Refnet Joint / Header, Refrigerant Joint / Header, Distribution / Branch Unit, Tees, Valves, Ball Valves, Fittings Like Bends, Elbow, Collars, Tees, Reducers, Flanges, Supports, Etc For Interconnecting The Liquid And Suction Lines Between Theoutdoor Units And The Indoor Units And Flare Connection To Indoor Units. Refrigerant Joints Supplied By Oem Only Shall Be Used. The Piping Shall Be Carried Out Of Soft / Hard Drawn Copper Pipes Brazed Socket Fittings. Both The Suction And Liquid Lines Shall Be Insulated With Closed Cell Nitrile Rubber Tubular Insulation With Factory Laminated Glass Cloth And Uv Paniting Of Thickness As Specified In Tender Including Pressure Testing And Charging Of Refrigerant And Oil. Refrigerant Piping And Cables In Wall Crossings Shall Be Provided In Suitable Steel / Pvc Sleeve All As Specified And / Or Directed Etc., Complete. Note: 1 ) Only The Cable Tray Supports Provided For Exposed Refrigerant Pipes Will Be Measured And Paid Under The Relevant Item Of Soqr. , Erection And Testing And Commissioning Of Size 15.9 Mm Dia Refrigerant Grade Copper Piping Of 20 Gauge Including Nitrile Rubber Tubular Insulation, Adhesive Tape, Including All Kinds Of Valves / Joints Viz., Refnet Joint / Header, Refrigerant Joint / Header, Distribution / Branch Unit, Tees, Valves, Ball Valves, Fittings Like Bends, Elbow, Collars, Tees, Reducers, Flanges, Supports, Etc For Interconnecting The Liquid And Suction Lines Between Theoutdoor Units And The Indoor Units And Flare Connection To Indoor Units. Refrigerant Joints Supplied By Oem Only Shall Be Used. The Piping Shall Be Carried Out Of Soft / Hard Drawn Copper Pipes Brazed Socket Fittings. Both The Suction And Liquid Lines Shall Be Insulated With Closed Cell Nitrile Rubber Tubular Insulation With Factory Laminated Glass Cloth And Uv Paniting Of Thickness As Specified In Tender Including Pressure Testing And Charging Of Refrigerant And Oil. Refrigerant Piping And Cables In Wall Crossings Shall Be Provided In Suitable Steel / Pvc Sleeve All As Specified And / Or Directed Etc., Complete. Note: 1 ) Only The Cable Tray Supports Provided For Exposed Refrigerant Pipes Will Be Measured And Paid Under The Relevant Item Of Soqr. , Supply Of Size 12.7 Mm Dia Refrigerant Grade Copper Piping Of 20 Gauge Including Nitrile Rubber Tubular Insulation, Adhesive Tape, Including All Kinds Of Valves / Joints Viz., Refnet Joint / Header, Refrigerant Joint / Header, Distribution / Branch Unit, Tees, Valves, Ball Valves, Fittings Like Bends, Elbow, Collars, Tees, Reducers, Flanges, Supports, Etc For Interconnecting The Liquid And Suction Lines Between Theoutdoor Units And The Indoor Units And Flare Connection To Indoor Units. Refrigerant Joints Supplied By Oem Only Shall Be Used. The Piping Shall Be Carried Out Of Soft / Hard Drawn Copper Pipes Brazed Socket Fittings. Both The Suction And Liquid Lines Shall Be Insulated With Closed Cell Nitrile Rubber Tubular Insulation With Factory Laminated Glass Cloth And Uv Paniting Of Thickness As Specified In Tender Including Pressure Testing And Charging Of Refrigerant And Oil. Refrigerant Piping And Cables In Wall Crossings Shall Be Provided In Suitable Steel / Pvc Sleeve All As Specified And / Or Directed Etc., Complete. Note: 1 ) Only The Cable Tray Supports Provided For Exposed Refrigerant Pipes Will Be Measured And Paid Under The Relevant Item Of Soqr. , Erection And Testing And Commissioning Of Size 12.7 Mm Dia Refrigerant Grade Copper Piping Of 20 Gauge Including Nitrile Rubber Tubular Insulation, Adhesive Tape, Including All Kinds Of Valves / Joints Viz., Refnet Joint / Header, Refrigerant Joint / Header, Distribution / Branch Unit, Tees, Valves, Ball Valves, Fittings Like Bends, Elbow, Collars, Tees, Reducers, Flanges, Supports, Etc For Interconnecting The Liquid And Suction Lines Between Theoutdoor Units And The Indoor Units And Flare Connection To Indoor Units. Refrigerant Joints Supplied By Oem Only Shall Be Used. The Piping Shall Be Carried Out Of Soft / Hard Drawn Copper Pipes Brazed Socket Fittings. Both The Suction And Liquid Lines Shall Be Insulated With Closed Cell Nitrile Rubber Tubular Insulation With Factory Laminated Glass Cloth And Uv Paniting Of Thickness As Specified In Tender Including Pressure Testing And Charging Of Refrigerant And Oil. Refrigerant Piping And Cables In Wall Crossings Shall Be Provided In Suitable Steel / Pvc Sleeve All As Specified And / Or Directed Etc., Complete. Note: 1 ) Only The Cable Tray Supports Provided For Exposed Refrigerant Pipes Will Be Measured And Paid Under The Relevant Item Of Soqr. , Supply Of Size 9.5 Mm Dia Refrigerant Grade Copper Piping Of 20 Gauge Including Nitrile Rubber Tubular Insulation, Adhesive Tape, Including All Kinds Of Valves / Joints Viz., Refnet Joint / Header, Refrigerant Joint / Header, Distribution / Branch Unit, Tees, Valves, Ball Valves, Fittings Like Bends, Elbow, Collars, Tees, Reducers, Flanges, Supports, Etc For Interconnecting The Liquid And Suction Lines Between Theoutdoor Units And The Indoor Units And Flare Connection To Indoor Units. Refrigerant Joints Supplied By Oem Only Shall Be Used. The Piping Shall Be Carried Out Of Soft / Hard Drawn Copper Pipes Brazed Socket Fittings. Both The Suction And Liquid Lines Shall Be Insulated With Closed Cell Nitrile Rubber Tubular Insulation With Factory Laminated Glass Cloth And Uv Paniting Of Thickness As Specified In Tender Including Pressure Testing And Charging Of Refrigerant And Oil. Refrigerant Piping And Cables In Wall Crossings Shall Be Provided In Suitable Steel / Pvc Sleeve All As Specified And / Or Directed Etc., Complete. Note: 1 ) Only The Cable Tray Supports Provided For Exposed Refrigerant Pipes Will Be Measured And Paid Under The Relevant Item Of Soqr. , Erection And Testing And Commissioning Of Size 9.5 Mm Dia Refrigerant Grade Copper Piping Of 20 Gauge Including Nitrile Rubber Tubular Insulation, Adhesive Tape, Including All Kinds Of Valves / Joints Viz., Refnet Joint / Header, Refrigerant Joint / Header, Distribution / Branch Unit, Tees, Valves, Ball Valves, Fittings Like Bends, Elbow, Collars, Tees, Reducers, Flanges, Supports, Etc For Interconnecting The Liquid And Suction Lines Between Theoutdoor Units And The Indoor Units And Flare Connection To Indoor Units. Refrigerant Joints Supplied By Oem Only Shall Be Used. The Piping Shall Be Carried Out Of Soft / Hard Drawn Copper Pipes Brazed Socket Fittings. Both The Suction And Liquid Lines Shall Be Insulated With Closed Cell Nitrile Rubber Tubular Insulation With Factory Laminated Glass Cloth And Uv Paniting Of Thickness As Specified In Tender Including Pressure Testing And Charging Of Refrigerant And Oil. Refrigerant Piping And Cables In Wall Crossings Shall Be Provided In Suitable Steel / Pvc Sleeve All As Specified And / Or Directed Etc., Complete. Note: 1 ) Only The Cable Tray Supports Provided For Exposed Refrigerant Pipes Will Be Measured And Paid Under The Relevant Item Of Soqr. , Supply Of Cpvc ( Sdr11 ) Pipes Of 32 Mm Dia, Schedule 40 With 9 Mm Thick Elastomeric Nitrile Rubber Tubular Insulation With Factorylaminated Glass Cloth And Uv Paniting For Condensate Water Drain From The Ac Indoor Units To Nearest Drain Point, Fittings, Supportetc. Complete , Installation Of Cpvc ( Sdr11 ) Pipes Of 32 Mm Dia, Schedule 40 With 9 Mm Thick Elastomeric Nitrile Rubber Tubular Insulation With Factory Laminated Glass Cloth And Uv Paniting For Condensate Water Drain From The Ac Indoor Units To Nearest Drain Point, Fittings, Supportincluding Core Cutting In Brick / Concrete Wall As Required And Making Surface Good Etc. Complete , Supply Of Cpvc ( Sdr11 ) Pipes Of 40 Mm Dia, Schedule 40 With 9 Mm Thick Elastomericnitrile Rubber Tubular Insulation With Factory Laminated Glass Cloth And Uv Panitingfor Condensate Water Drain From The Ac Indoor Units To Nearest Drain Point, Fittings, Supportetc. Complete , Installation Of Cpvc ( Sdr11 ) Pipes Of 40 Mm Dia, Schedule 40 With 9 Mm Thick Elastomeric Nitrile Rubber Tubular Insulation With Factory Laminated Glass Cloth And Uv Paniting For Condensate Water Drain From The Ac Indoor Units To Nearest Drain Point, Fittings, Supportincluding Core Cutting In Brick / Concrete Wall As Required And Making Surface Good Etc. Complete , Structural Steel Worksmade Of Channels, Angles, Plates, Flats, Pipes, Cleats Etc., Including Welding At Shop Or At Work Site Including Painting With Two Coats Of Synthetic Enamel Paint Of Approved Make And Shade, Over A Coat Of Approved Steel Primer Etc., Complete , Supply And Fixing Of 6 Pin 15 / 16 Amps Modular Switch-Socket Outlet, Isi Marked Above False Ceiling For Indoor Cassette Ac Units , Wiring For Power Cirucit With 2X4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Alongwith 1 No. 4 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. , Supplying And Fixing Of 20Mm Dia Size Steel Conduit Pipes Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , Supply Of 4Cx6 2Xfy Cppper Cable, Xlpe Insulated, Pvc Sheathed, Armoured, 1.1Kv Grade Lt Cable For Vrv Outdoor Unit. , Laying And End Termination Of 4Cx6 2Xfy Cppper Cable, Xlpe Insulated, Pvc Sheathed, Armoured, 1.1Kv Grade Lt Cable. , Supply Of 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness Of Perforated Hot Dipped Galvanised Iron Cable Tray ( Galvanisation Thickness Not Less Than 50 Microns ) With Perforation Not More Than 17.5%. , Fixing Of 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness Of Perforated Hot Dipped Galvanised Iron Cable Tray ( Galvanisation Thickness Not Less Than 50 Microns ) Suspended Form Ceiling Or On Wall Including G.I. Bolts & Nuts, Etc. Along With Bends, Tee Joints Or Necessary Accessories As Required. , Supply And Bonding Of 6 Swg Gi Wire For Earthing And Bonding With The Exisiting Earthing System , Supply And Fixing Of 32A Tpn+E Outdoor Rated ( Min.Ip 65 ) Industrial Plug Socket With Mcb Control. , Supply And Installation Of Mcb Enclosure Box Consisting Of 32A Tpn Mcb Controlled By 24Hr Timer Contactor With Time Setting Functionality For Auto On / Off Of The Vrv Unit. , Installation, Testing And Commissioning Of Inverter Type Hi Wall Split Ac With 2.0Tr Capacity With R410a / R32 Refrigerant Gas, Wireless Remote Controller, Cooling Thermostat, Required Length Of Power Cable And Control Cable Between Indoor And Outdoor Units, Earthing, Supports Etc. Complete , Supply Of Refrigerant Grade Copper Piping Between Indoorand Outdoor Units Of Suitable Size ( Both Suction And Discharge Piping Will Be Treated As One Unit And Will Not Be Measured Separately ) , Suction Line With Insulation And Discharge Line Without Insulation Including All Fittings, Accessories, Core Cutting In Brick / Concrete Wall And Making Surface Good, Supports Etc. For 2Tr Capacity Hi Wall Ac Unit , Erection, Testing And Commissioning Of Refrigerant Grade Copper Piping Between Indoorand Outdoor Units Of Suitable Size ( Both Suction And Discharge Piping Will Be Treated As One Unit And Will Not Be Measured Separately ) , Suction Line With Insulation And Discharge Line Without Insulation Including All Fittings, Accessories, Core Cutting In Brick / Concrete Wall And Making Surface Good, Supports Etc. For 2Tr Capacity Hi Wall Ac Unit , Supply Of Cpvc ( Sdr11 ) Pipes Of 25 Mm Dia With 9 Mm Thick Elastomeric Nitrile Rubber Tubular Insulation With Factory Laminated With Glass Cloth And Uv Paniting For Condensate Water Drain From The Ac Indoor Units To Nearest Drain Point, Fittings, Supportetc. Complete , Installation Of Cpvc ( Sdr11 ) Pipes Of 25 Mm Dia With 9 Mm Thick Elastomeric Nitrile Rubber Tubular Insulation Factory Laminated With Glass Cloth And Uv Paniting For Condensate Water Drain From The Ac Indoor Units To Nearest Drain Point, Fittings, Supportincluding Core Cutting In Brick / Concrete Wall As Required And Making Surface Good Etc. Complete , Supply Of Pvc Covering Pipe Of Size 75Mm Suitable For Exposed Refrigerant Pipes & Cabling Between The Indoor And Outdoor Units Forac Units , Erection, Testing And Commissioning Of Pvc Covering Pipe Of Size 75Mm Suitable For Exposed Refrigerant Pipes & Cabling Between The Indoor And Outdoor Units Forac Units , Wiring For Power Circuit With 2X6 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Steel Conduit Alongwith 1 No. 6 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable For Loop Earthing As Required. , Supplying And Fixing Of 20Mm Dia Size Steel Conduit Pipes Along With Accessories In Surface / Recess Including Painting In Case Of Surface Conduit, Or Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , Supply And Bonding Of 6 Swg Gi Wire For Earthing And Bonding With The Exisiting Earthing System , Supply And Fixing Of 20A Spnindoor Rated ( Min.Ip 44 ) Industrial Plug Socket With Mcb Control For Hi-Wall Split Ac. , Supply, Fixing And Installation Of Timer Distribution Board For Changeover Operation Of Acs For Every 8 Hours. Db Shall Be Able To Control Min. 04 Nos. Of Hi-Wall Split Ac Units. The Timer Db Shall Have Provison For Changeover Time Setting As Per Requirement.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 23-Dec-2022 Corrigendum-1, Date Extension for Supply Installation Testing and Commissioning of VRV VRF AC ODU 6HP VRV VRF Cassette AC IDU 2 TR and 2TR HW Inverter Type With 410A Gas at ADSN Building. Date 24-12-2022

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

BOQ Items

Name of Work:Supply , Installation , Testing and Commissioning of VRV/VRF AC ODU 6HP, VRV/VRF Cassette AC IDU 2 TR & 2TR HW Inverter Type With 410A Gas at ADSN Building.
Sl. No. Item Description
1Supply of variable refrigerant volume (VRV) / variable refrigerant flow (VRF) type air conditioning system"s outdoor unit of capacity not less than 6 HP, equiped with highly efficient hermetic scroll compressor or twin rotary type compressors, equipped with inverter control capable of changing the speed in accordance to the cooling load requirement, heat exchanger, low noise condenser fan, outdoor unit multiple connecting unit, including first charge of R410a refrigerant & oil, etc. The inverter shall be IGBT type to be efficient and quiet operation. The outdoor unit shall have the multi-step of capacity control to meet load fluctuation. The quoted price shall include MS angle base frame structure duly black painted with synthetic epoxy paint for all outdoor units. The frame structure shall be mounted on MS plate & serrated rubber pads all as specified and / or directed etc., complete. Note: The quotedrate for this item deemed to include the cost for necessary hardware, software, gateway, interface, controller etc.
2Supply of variable refrigerant volume (VRV) / variable refrigerant flow (VRF) type air conditioning system"s indoor unit of Cassette ACof capacity not less than 2.0TR (7.0 kW) with cordless remote for individual unit, cooling coil, expansion valve, multi speed fan, motor, power wiring from nearest power socket to indoor unit etc. The blower shall be dynamically balanced and designed for silent operation, the drain pan shall be fabricated out of heavy sheet steel with insulation, MS brackets / supports, all as specified and / or directed etc., complete.
3Supply of Inverter type Hi Wall Split AC with 2.0TR capacity with R410a / R32 refrigerant gas, wireless remote controller, cooling thermostat, required length of power cable and control cable between indoor and outdoor units, earthing, supports etc. complete
4Installation, testing and commissioning of variable refrigerant volume (VRV) / variable refrigerant flow (VRF) type air conditioning system"s outdoor unit of capacity not less than 6 HP, equiped with highly efficient hermetic scroll compressor or twin rotary type compressors, equipped with inverter control capable of changing the speed in accordance to the cooling load requirement, heat exchanger, low noise condenser fan, outdoor unit multiple connecting unit, including first charge of R410a refrigerant & oil, etc. The inverter shall be IGBT type to be efficient and quiet operation. The outdoor unit shall have the multi-step of capacity control to meet load fluctuation. The quoted price shall include MS angle base frame structure duly black painted with synthetic epoxy paint for all outdoor units. The frame structure shall be mounted on MS plate & serrated rubber pads all as specified and / or directed etc., complete.
5Installation, testing and commissioning of variable refrigerant volume (VRV) / variable refrigerant flow (VRF) type air conditioning system"s indoor unit of Cassette ACof capacity not less than 2.0TR(7.0 kW) with cordless remote for individual unit, cooling coil, expansion valve, multi speed fan, motor, power wiring from nearest power socket to indoor unit etc. The blower shall be dynamically balanced and designed for silent operation, the drain pan shall be fabricated out of heavy sheet steel with insulation, MS brackets / supports, all as specified and / or directed etc., complete.
6Supply of size 22.2 mm dia refrigerant grade copper piping of 20 gauge including nitrile rubber tubular insulation, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between theoutdoor units and the indoor units and flare connection to indoor units. Refrigerant joints supplied by OEM only shall be used. The piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. Both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation with factory laminated glass cloth and UV paniting of thickness as specified in tender including pressure testing and charging of refrigerant and oil. Refrigerant piping and cables in wall crossings shall be provided in suitable steel / PVC sleeve all as specified and/ or directed etc., complete. Note: 1) Only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of SOQR.
7Erection and testing and commissioning of size 22.2 mm dia refrigerant grade copper piping of 20 gauge including nitrile rubber tubular insulation, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between theoutdoor units and the indoor units and flare connection to indoor units. Refrigerant joints supplied by OEM only shall be used. The piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. Both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation with factory laminated glass cloth and UV paniting of thickness as specified in tender including pressure testing and charging of refrigerant and oil. Refrigerant piping and cables in wall crossings shall be provided in suitable steel / PVC sleeve all as specified and/ or directed etc., complete. Note: 1) Only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of SOQR.
8Supply of size 19.1 mm dia refrigerant grade copper piping of 20 gauge including nitrile rubber tubular insulation, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between theoutdoor units and the indoor units and flare connection to indoor units. Refrigerant joints supplied by OEM only shall be used. The piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. Both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation with factory laminated glass cloth and UV paniting of thickness as specified in tender including pressure testing and charging of refrigerant and oil. Refrigerant piping and cables in wall crossings shall be provided in suitable steel / PVC sleeve all as specified and/ or directed etc., complete. Note: 1) Only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of SOQR.
9Erection andtesting and commissioning of size 19.1 mm dia refrigerant grade copper piping of 20 gauge including nitrile rubber tubular insulation, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between theoutdoor units and the indoor units and flare connection to indoor units. Refrigerant joints supplied by OEM only shall be used. The piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. Both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation with factory laminated glass cloth and UV paniting of thickness as specified in tender including pressure testing and charging of refrigerant and oil. Refrigerant piping and cables in wall crossings shall be provided in suitable steel / PVC sleeve all as specified and/ or directed etc., complete. Note: 1) Only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of SOQR.
10Supply of size 15.9 mm dia refrigerant grade copper piping of 20 gauge including nitrile rubber tubular insulation, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between theoutdoor units and the indoor units and flare connection to indoor units. Refrigerant joints supplied by OEM only shall be used. The piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. Both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation with factory laminated glass cloth and UV paniting of thickness as specified in tender including pressure testing and charging of refrigerant and oil. Refrigerant piping and cables in wall crossings shall be provided in suitable steel / PVC sleeve all as specified and/ or directed etc., complete. Note: 1) Only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of SOQR.
11Erection and testing and commissioning of size 15.9 mm dia refrigerant grade copper piping of 20 gauge including nitrile rubber tubular insulation, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between theoutdoor units and the indoor units and flare connection to indoor units. Refrigerant joints supplied by OEM only shall be used. The piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. Both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation with factory laminated glass cloth and UV paniting of thickness as specified in tender including pressure testing and charging of refrigerant and oil. Refrigerant piping and cables in wall crossings shall be provided in suitable steel / PVC sleeve all as specified and/ or directed etc., complete. Note: 1) Only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of SOQR.
12Supply of size 12.7 mm dia refrigerant grade copper piping of 20 gauge including nitrile rubber tubular insulation, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between theoutdoor units and the indoor units and flare connection to indoor units. Refrigerant joints supplied by OEM only shall be used. The piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. Both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation with factory laminated glass cloth and UV paniting of thickness as specified in tender including pressure testing and charging of refrigerant and oil. Refrigerant piping and cables in wall crossings shall be provided in suitable steel / PVC sleeve all as specified and/ or directed etc., complete. Note: 1) Only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of SOQR.
13Erection and testing and commissioning of size 12.7 mm dia refrigerant grade copper piping of 20 gauge including nitrile rubber tubular insulation, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between theoutdoor units and the indoor units and flare connection to indoor units. Refrigerant joints supplied by OEM only shall be used. The piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. Both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation with factory laminated glass cloth and UV paniting of thickness as specified in tender including pressure testing and charging of refrigerant and oil. Refrigerant piping and cables in wall crossings shall be provided in suitable steel / PVC sleeve all as specified and/ or directed etc., complete. Note: 1) Only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of SOQR.
14Supply of size 9.5 mm dia refrigerant grade copper piping of 20 gauge including nitrile rubber tubular insulation, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between theoutdoor units and the indoor units and flare connection to indoor units. Refrigerant joints supplied by OEM only shall be used. The piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. Both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation with factory laminated glass cloth and UV paniting of thickness as specified in tender including pressure testing and charging of refrigerant and oil. Refrigerant piping and cables in wall crossings shall be provided in suitable steel / PVC sleeve all as specified and/ or directed etc., complete. Note: 1) Only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of SOQR.
15Erection and testing and commissioning of size 9.5 mm dia refrigerant grade copper piping of 20 gauge including nitrile rubber tubular insulation, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between theoutdoor units and the indoor units and flare connection to indoor units. Refrigerant joints supplied by OEM only shall be used. The piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. Both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation with factory laminated glass cloth and UV paniting of thickness as specified in tender including pressure testing and charging of refrigerant and oil. Refrigerant piping and cables in wall crossings shall be provided in suitable steel / PVC sleeve all as specified and/ or directed etc., complete. Note: 1) Only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of SOQR.
16Supply of cPVC (SDR11) pipes of 32 mm dia, Schedule 40 with 9 mm thick elastomeric nitrile rubber tubular insulation with factorylaminated glass cloth and UV paniting for condensate water drain from the AC indoor units to nearest drain point, fittings, supportetc. complete
17Installation of cPVC (SDR11) pipes of 32 mm dia, Schedule 40 with 9 mm thick elastomeric nitrile rubber tubular insulation with factory laminated glass cloth and UV paniting for condensate water drain from the AC indoor units to nearest drain point, fittings, supportincluding core cutting in brick/ concrete wall as required and making surface good etc. complete
18Supply of cPVC (SDR11) pipes of 40 mm dia, Schedule 40 with 9 mm thick elastomericnitrile rubber tubular insulation with factory laminated glass cloth and UV panitingfor condensate water drain from the AC indoor units to nearest drain point, fittings, supportetc. complete
19Installation of cPVC (SDR11) pipes of 40 mm dia, Schedule 40 with 9 mm thick elastomeric nitrile rubber tubular insulation with factory laminated glass cloth and UV paniting for condensate water drain from the AC indoor units to nearest drain point, fittings, supportincluding core cutting in brick/ concrete wall as required and making surface good etc. complete
20Structural steel worksmade of channels, angles, plates, flats, pipes, cleats etc., including welding at shop or at work site including painting with two coats of synthetic enamel paint of approved make and shade, over a coat of approved steel primer etc., complete
21Supply and fixing of 6 pin 15/16 amps modular switch-socket outlet, ISI marked above false ceiling for Indoor cassette AC units
22Wiring for power cirucit with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
23Supplying and fixing of 20mm dia size steel conduit pipes along with accessories in surface/ recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
24Supply of 4Cx6 2XFY Cppper cable, XLPE insulated, PVC sheathed, armoured,1.1kV grade LT cable for VRV outdoor unit.
25Laying and end termination of 4Cx6 2XFY Cppper cable, XLPE insulated, PVC sheathed, armoured,1.1kV grade LT cable.
26Supply of 150 mm width X 50 mm depth X 1.6 mm thickness of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%.
27Fixing of 150 mm width X 50 mm depth X 1.6 mm thickness of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) suspended form ceiling or on wall including G.I. bolts & nuts, etc. along with bends, Tee joints or necessary accessories as required.
28Supply and bonding of 6 SWG GI wire for earthing and bonding with the exisiting earthing system
29Supply and fixing of 32A TPN+E outdoor rated(min.IP 65) industrial plug socket with MCB control.
30Supply and installation of MCB enclosure box consisting of 32A TPN MCB controlled by 24hr timer contactor with time setting functionality for auto ON/OFF of the VRV unit.
31Installation, testing and commissioning of Inverter type Hi Wall Split AC with 2.0TR capacity with R410a / R32 refrigerant gas, wireless remote controller, cooling thermostat, required length of power cable and control cable between indoor and outdoor units, earthing, supports etc. complete
32Supply of refrigerant grade copper piping between indoorand outdoor units of suitable size ( both suction and discharge piping will be treated as one unit and will not be measured separately), suction line with insulation and discharge line without insulation including all fittings, accessories, core cutting in brick/ concrete wall and making surface good, supports etc. for 2TR capacity Hi wall AC unit
33Erection, testing and commissioning of refrigerant grade copper piping between indoorand outdoor units of suitable size ( both suction and discharge piping will be treated as one unit and will not be measured separately), suction line with insulation and discharge line without insulation including all fittings, accessories, core cutting in brick/ concrete wall and making surface good, supports etc. for 2TR capacity Hi wall AC unit
34Supply of cPVC (SDR11) pipes of 25 mm dia with 9 mm thick elastomeric nitrile rubber tubular insulation with factory laminated with glass cloth and UV paniting for condensate water drain from the AC indoor units to nearest drain point, fittings, supportetc. complete
35Installation of cPVC (SDR11) pipes of 25 mm dia with 9 mm thick elastomeric nitrile rubber tubular insulation factory laminated with glass cloth and UV paniting for condensate water drain from the AC indoor units to nearest drain point, fittings, supportincluding core cutting in brick/ concrete wall as required and making surface good etc. complete
36Supply of PVC Covering pipe of size 75mm suitable for exposed refrigerant pipes & cabling between the indoor and outdoor units forAC units
37Erection, testing and commissioning of PVC Covering pipe of size 75mm suitable for exposed refrigerant pipes & cabling between the indoor and outdoor units forAC units
38Wiring for power circuit with 2X6 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 6 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
39Supplying and fixing of 20mm dia size steel conduit pipes along with accessories in surface/ recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
40Supply and bonding of 6 SWG GI wire for earthing and bonding with the exisiting earthing system
41Supply and fixing of 20A SPNindoor rated(min.IP 44) industrial plug socket with MCB control for hi-wall split AC.
42Supply, fixing and installation of Timer Distribution Board for changeover operation of AC"s for every 8 hours. DB shall be able to control min. 04 nos. of Hi-wall Split AC units. The Timer DB shall have provison for changeover time setting as per requirement.