}

Tender For Supply Erection And Commissioning Of 01 No 10 Cs Pump (P-4), 05 Nos. 30 Hp And 02 Nos 60 Hp Lt Induction Motors, Ltd Panels, Cable Of Various Sizes And Other Electrical Equipments At Pump House Dd-8, Dd-9 Jaula Mr., rewari-Haryana

Irrigation Department has published Tender For Supply Erection And Commissioning Of 01 No 10 Cs Pump (P-4), 05 Nos. 30 Hp And 02 Nos 60 Hp Lt Induction Motors, Ltd Panels, Cable Of Various Sizes And Other Electrical Equipments At Pump House Dd-8, Dd-9 Jaula Mr.. Submission Date for this Tender is 06-01-2023. Bolts Tenders in rewari Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

35288124
Corrigendum : Tender For Supply Erection And Commissioning Of 01 No 10 Cs Pump (P-4), 05 Nos. 30 Hp And 02 Nos 60 Hp Lt Induction Motors, Ltd Panels, Cable Of Various Sizes And Other Electrical Equipments At Pump House Dd-8, Dd-9 Jaula Mr.
Tender
Indian
Haryana
Rewari
06-01-2023

Tender Details

Tender For Supply Erection And Commissioning 01 No 10 Cs Pump ( P-4 ) , 05 Nos. 30 Hp And 02 Nos 60 Hp Lt Induction Motors, Ltd Panels, Cable Of Various Sizes And Other Electrical Equipments At Pump House Dd-8, Dd-9 Jaula Mr. - Supply, Errection And Commissioning Of 10Cs. ( P-4 ) Axial / Mixed Flow Vt Pump Of 960 Rpm Having Static Lift 29Ft, Incl. Welding, Hs Nut-Bolts Etc. Complete In All Respect As Per Site Requirement, With New Delivery Pipe ( Length 28±1 Feet ) & Siphon Bend And As Per Approved Specification Of The Deptt. ( As Per Annexure-A ) ( Dd-8 ) 2 Supply, Errection And Commissioning Of Solid Shaft Squirrel Cage Lt 3 Phase 415V Induction Motor For Continuous Duty, Vertical Flange Mounted Of 60 Hp Of 6 Pole, 980 Rpm, Tefc Motor Of Ie 2 As Per Is 12615. The Colour Shade Shall Be Ral 7031, Suitable For Existing 10Cs Pump Complete In All Respect & As Per Approved Specification Of Deptt. ( As Per Annexure-B ) ( At Dd-8 ) 3 Supply, Erection And Commissioning Of Hollow Shaft Squirrel Cage Lt 3 Phase 415V Induction Motor For Continuous Duty, Vertical Flange Mounted Of 30 Hp Of 4 Pole, 1470 Rpm, Tefc Motor Of Ie 2 As Per Is 12615. The Colour Shade Shall Be Ral 7031, Suitable For 5Cs Pump Complete In All Respect & As Per Approved Specification Of Deptt. ( As Per Annexure-B ) ( For Dd-8, Dd-9 &Jaula Minor ) 4 Supply, Erection And Commissioning Of Ltd Panel With Incomer Of Mccb Of 400 Amp., 4 Pole 415 V, 50 Hz, With 2 No. 160Amp And 02 No. 80Amp. Outgoing And Having Provision Of Additional D Plug Socket Of 63 Ampere And Lightening Load Along With All Metering Equipment Ct’S Of Required Capacity Complete In All Respect & As Per Makes And Specifications Approvedas Detailed In Annexure-C. ( At Dd-8 ) 5 Supply, And Laying Of Lt Single Core Aluminum Conductor 185Mm2 Xlpe Insulated, Armoured Cable From Transformer To Panel By Providing Suitable Size Thimbles At Both Ends. . ( At Dd-8 ) 6 Supply, And Laying Of Lt Single Core Aluminum Conductor 95Mm2 Xlpe Insulated, Armoured Cable From Transformer To Panel By Providing Suitable Size Thimbles At Both Ends. ( At Dd-9, Jaula Minor ) 7 Supply, Erection And Commissioning Of Capacitor Bank Of 60 Kvar Capacity Ip-54 With 04Step Automatic Power Factor Controller Relay Unit, Suitable Size Mccb, Duty Contactors, Discharge Registers, Display Unit, On / Off Switches, Selector Switch Automatic As Well As Manual, Indicators And All Other Related Components With Xlpe Insulated Armored Cable Of Suitable Size Of Length 35 Feet Each To Connect The Capacitor Bank With Existing Lt Panels With Stand Of Ms Channel, Angle ( 1Feet Height Above From Floor Level. ) And As Per Approved Specification Of The Deptt. ( At Dd-8 ) 8 Supply Of Lt Power Distribution Panel With Incomer Of Mccb Of 100 Amp., 4 Pole 415 V, 50 Hz, 36 Ka, Ct Ratio 200 / 5 Mdu With 02 No. Outgoing Including 2 No. 50 Amp. Mccb And Having Additional Provision Ofd Plug Socket Of 63 Ampere And Lightening Load Along With All Metering Equipment Ct’S Of Required Capacity Complete In All Respect As Per Makes And Specifications Approved By Irrigation & Water Resources Department, Haryana As Detailed In Annexure-C Attached. ( Jaula Minor ) 9 Providing And Fixing Of Lightening Arrester With Protection Radios Of 100Mtr. Along With Itsearthing As Per The Site Requirement. ( For Dd-8, Dd-9 &Jaula Minor ) 10 Providing And Fixing Of Chemical Earthing By Digging 200 Mm Bore, 20 Feet Depth Complete With Gi Electrode With Gi Strip ( 02 Nos. For Ltdb Panels Starters & Motors In Pump House ) And Coke & Salt Etc. Along With Name Plate Complete As Per Requirement. ( For Dd-8, Dd-9 &Jaula Minor )

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 01-01-2023 DATE Date 06-01-2023
2 22-12-2022 pre-bid Other 28-12-2022
3 27-12-2022 Corrigendum Date 02-01-2023
4 28-12-2022 Mechanism of grievance redressal Other 02-01-2023

Key Value

Document Fees
INR 15000 /-
EMD
INR 126000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail