Tender For Re-Installation Of 30 Mtr Height High Masts At Wharf, mangaluru-Karnataka

New Mangalore Port Trust-NMPT has published Tender For Re-Installation Of 30 Mtr Height High Masts At Wharf. Submission Date for this Tender is 27-12-2022. Bolts Tenders in mangaluru Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

35274079
Tender For Re-Installation Of 30 Mtr Height High Masts At Wharf
Open Tender
Indian
Karnataka
mangaluru
27-12-2022

Tender Details

Tender For Re-Installation Of 30 Mtr Height High Masts At Wharf -Supply Of 12 Nos. Foundation Bolts For 30 Mtr Height High Mast Manufactured From Special Steel Along With Nuts, Washers, Anchor Plate And Common Template Etc. Complete 2 Construction Of High Mast Foundation With M 25 Grade Concrete For The High Mast Considering The Safe Soil Bearing Capacity At Site As10 T / Sq.Mtr At 2 Meter Depth With All Materials And Labour 3 Erection Of High Mast Tower With The Help Of Suitable Tools And Plants, Wiring Of Luminaries With All Wiring Materials Like Pvc Insulated Pvc Sheathed Flexible Cable Of Suitable Copper Conductor 3Core Of 1.5 Sq. Mm, Lugs, Mcb And All Labouretc., Complete. High Mast Towers & Light Fittings Will Be Provided By The Department 4 Providing Rcc / Stone Masonry Foundation For The High Mast Control Panel And The Dimension Of The Foundation Is 800 ( W ) X 1000 ( H ) X 400 ( D ) Mm And Gap Between The Pillars Is 350 Mm For Cable Connection To The Control Panel. The Foundation Starts 300Mm Below The Groundafter Making 100Mm Stone Soling And Height Of The Foundation 500Mm Above The High Mast Foundation Level And Curing Etc. And The Panel Should Stand On The Four Stainless Steel Bolts ( 12Mm X 6” ) And Each Bolt With Four Nuts & Washers At 50Mm Height From The Foundation And Complete 5 Providing Gi Pipe Earthing For High Mast & Feeder Pillars Using 40 Mm Dia 2.9 Mm Thick, 2.5 Meter Long Gi Pipe With Gi Funnel With Mesh And Suitable Size Reducer Fixed On The Top Of The Earth Electrode. The Funnel Should Be Enclosed In A Cc Chamber Of 400 X 400 X 400 Mm With A Cast Iron Cover. The Electrode Shall Have Staggered Holes Of 12-Mm Dia And The Electrode Should Be Covered 150 Mm Around With Alternate Layers Of Salt And Charcoal From The Bottom Of The Pipe To The Bottom Of The Cc Chamber The Connection From The Electrode Is To Be Established Through Gi Flats. ( 25X3mm For Lighting And Panel & 50 X 6Mm For Lightning Arrestor ) Using Gi Bolts And Nuts. Work Includes Supply & Fixing Of Required Gi Flats For Each Earthing Connection 6 Installation And Commissioning Of The Stainless Steel High Mast Control Panel By Terminating The Required Cables Such As Incomer, Lighting And Motor. Work Also Includs Supply And Fixing Of Required Materials Such As Glands Lugs, Etc. Complete 7 Supplying Of Lt Ug Cable 4Cx16 Sq.Mm Having Aluminium Conductor Xlpe Insulated, Sheathed, Galvanized, Steel Wire, Steel Tape Armoured Cable 1.1 Kv Class 8 Labour Charges For Laying Of 4Cx16sq Mm Cable In Existing Trench On Wall / On Structure As Required 9 Supplying And Making End Termination With Glands, Lugs Of Lt Cablesize 4Cx16sq.Mm Etc. Complete 10 Digging Of Trench Of 0.6M Deep X 0.5M Wide In Hard Soil, Refilling The Trench To The Required Ground Level And Consolidating Etc., Complete 11 Digging Of Trench Of 0.6M Deep X 0.5M Wide For Cc Cutting, Refilling The Trench To The Required Ground Level And Consolidating Etc., Complete 12 Supplying & Laying Of Dwc Hdpe Pipe Including All Connecting Sockets / Coupling / Tees / Bends / Cap Of Same Materials In Existing Trench, On Drain / Road Crossing For Drawing Ug Cable 13 Increasing The Height Of The Existing Feeder Pillar Foundation By 2 Feet From The Ground Level Using Laterite Stones And Also For Re-Termination Of 1 No. 3.5C X 400 Sq.Mm Lt Ug Cable To The Existing Feeder Pillar 14 Making Core Cutting Of Size 300Mm Dia ( 2 Nos. ) For Cable Entry To The Panel Including Finishing The Core Etc. Complete 15 Supplying Of 6Mm Dia. Steel Wire Rope, Aisi: 316 Of 7X19construction, Each 63Mtr Length Including Supply And Fixing Of Timbles, D- Clamps ( Gi / Ss ) Bolts, Nuts, Washers Etc., Complete 16 Supplying Of 5Cx4 Sq.Mmepr Insulatedpcp Sheathed Copper Flexiblehigh Mast Trailing Cable

Key Value

Document Fees
INR 560 /-
EMD
INR 16700.0 /-
Tender Value
INR 7.07 Lakhs /-

BOQ Items

Name of Work:Re-installation of 30 Mtr height High Masts at Wharf
Sl. No. Item Description
1Supply of 12 Nos. foundation bolts for 30 Mtr height High Mast manufactured from special steel along with nuts, washers, anchor plate and common template etc. complete
2Construction of High Mast foundation with M 25 grade concrete for the High Mast considering the safe soil bearing capacity at site as10 T/sq.mtr at 2 meter depth with all materials and labour
3Erection of High Mast Tower with the help of suitable tools and plants, wiring of luminaries with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor 3core of 1.5 sq. mm, lugs, MCB and all labouretc., complete. High Mast Towers & Light Fittings will be provided by the Department
4Providing RCC/Stone masonry foundation for the High Mast control Panel and the dimension of the foundation is 800(W) x 1000(H) x 400(D) mm and gap between the pillars is 350 mm for cable connection to the control panel. The foundation starts 300mm below the groundafter making 100mm stone soling and height of the foundation 500mm above the high Mast foundation level and curing etc. and the panel should stand on the four Stainless steel bolts (12mm x 6”)and each bolt with four nuts & washers at 50mm height from the foundation and complete
5Providing GI pipe earthing for High Mast & Feeder Pillars using 40 mm dia 2.9 mm thick, 2.5 meter long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400 x 400 x 400 mm with a cast iron cover. The electrode shall have staggered holes of 12-mm dia and the electrode should be covered 150 mm around with alternate layers of salt and charcoal from the bottom of the pipe to the bottom of the CC chamber the connection from the electrode is to be established through GI Flats. (25x3mm for lighting and panel & 50 x 6mm for lightning arrestor) using GI bolts and nuts. work includes supply & fixing of required GI flats for each earthing connection
6Installation and Commissioning of the Stainless Steel High Mast Control Panel by terminating the required cables such as Incomer, lighting and motor. Work also includs supply and fixing of required materials such as glands lugs, etc. complete
7Supplying of LT UG cable 4Cx16 sq.mm having Aluminium conductor XLPE insulated, sheathed, Galvanized, Steel wire, Steel tape armoured cable 1.1 KV class
8Labour charges for laying of 4cx16Sq mm cable in existing trench on wall/on structure as required
9Supplying and making end termination with glands, lugs of LT cablesize 4cx16sq.mm etc. complete
10Digging of trench of 0.6m deep x 0.5m wide in hard soil, refilling the trench to the required ground level and consolidating etc., complete
11Digging of trench of 0.6m deep x 0.5m wide for CC cutting, refilling the trench to the required ground level and consolidating etc., complete
12Supplying & Laying of DWC HDPE pipe including all connecting sockets/coupling/tees/bends/cap of same materials in existing trench, on drain/road crossing for drawing UG cable
13Increasing the height of the existing Feeder Pillar foundation by 2 feet from the ground level using laterite stones and also for re-termination of 1 No. 3.5C x 400 Sq.mm LT UG cable to the existing feeder pillar
14Making core cutting of size 300mm dia (2 Nos.) for cable entry to the panel including finishing the core etc. complete
15Supplying of 6mm Dia. Steel wire rope, AISI: 316 of 7x19construction,each 63Mtr length including supply and fixing of timbles, D- clamps (GI/SS) bolts, nuts, washers etc., complete
16Supplying of 5Cx4 Sq.mmEPR insulatedPCP sheathed copper flexibleHigh Mast trailing cable