Tender For Dgps Site Survey, Planning, ,Supply, Loading, Transportation, Unloading, Insurance, Delivery At Site, Handling, Storage, Installation, agartala-Tripura

Tripura State Electricity Corporation Limited-TSECL has published Tender For Dgps Site Survey, Planning, ,Supply, Loading, Transportation, Unloading, Insurance, Delivery At Site, Handling, Storage, Installation. Submission Date for this Tender is 02-01-2023. Miscellaneous Fasteners Tenders in agartala Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

35265430
Corrigendum : Tender For Dgps Site Survey, Planning, ,Supply, Loading, Transportation, Unloading, Insurance, Delivery At Site, Handling, Storage, Installation
Open Tender
Indian
Tripura
agartala
02-01-2023

Tender Details

Dgps Site Survey, Planning, ,Supply, Loading, Transportation, Unloading, Insurance, Delivery At Site, Handling, Storage, Installation

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Dec-2022 Corrigendum01 Fee 02-01-2023
2 22-Dec-2022 Corrigendum BOQ 02-01-2023

Key Value

Document Fees
INR 25000 /-
EMD
INR 6150000.0 /-
Tender Value
INR 30.73 Crore /-

BOQ Items

Name of Work: DGPS site survey, planning, supply, loading, transportation, unloading, insurance, delivery at site, handling, storage, installation, testing, commissioning and operation & maintenance for 3 years including documentation of all items/material required to complete works to convert existing overhead electrical line network into underground cabling at all the voltage levels of 33 KV, 11kV and LT including provision of Ring Main Units, Packaged Sub stations and other allied works for improving the power delivery mechanisms in the jurisdiction of Division No – I,Agartala City( Phase-I).
Sl. No. Item Description
1DGPS SURVEY WORK
2DGPS Survey, Submission of construction drawing of the Existing Electrical System and obtain NOC from various stakeholders : Detailed Survey of route alignment with covering of existing Distribution Sub-Station along with overhead Transmission/sub-transmission & distribution line , submission of route alignment, profile, final survey and DGPS survey with profile in details indicating road crossing, river, water body, Sewerage pipe line, Water supply pipe line, Gas pipe line and P&T line etc.
3Supply, Installation, Testing & Commissioning of 11kV RING MAIN UNIT (RMU)11/0.433kv Distribution Transformer(DT) and 11/0.433kV Compaq Sub-Sation(CSS):
4Supply, Installation, Testing & Commissioning of 11kV RING MAIN UNIT (RMU) : 12KV motorised ringmain unit, self powered typewith CPTor by other means, solid or SF6 installation, outdoor enclouser, FPI, battery and charging system, software, all accessories and tools as provied in Bid document. 5 way RMU Type SBSSS
5Supply, Installation, Testing & Commissioning of 11kV RING MAIN UNIT (RMU) : 12KV motorised ringmain unit, self powered typewith CPTor by other means, solid or SF6 installation, outdoor enclouser, FPI, battery and charging system, software, all accessories and tools as provied in Bid document. 6 way RMU Type SBBBSS
6(A)Compact Substation - 500kVA: Design, Manufacturer and Supply of11/0.400kV Outdoor type Compact Sub-Station,equipped with 500KVA11KV/433V, DYn11 Oil filled hermatically sealed transformer, 3 Way 11kV Ring Main Unit consisting of 2 nos. 630A at 11kV load breaking switch with one no tee-off as SF6 insulated 400Amp. Vacuum Circuit Breaker & with 800Amps 400V 36KA 4P Fixed Manual Air Circuit Breaker with numerical overcurrent and earthfault protection as secondary side control as detailed below. The detail bill of material for each Compact Substation shall be as under(1)HT Switchgear: Three way 11KV Non-Extensible Ring Main Unit Compact switchgear consisting of 630 A two numbers fixed manual fault making / Load break Switches & one numbers Fixed manual SF6 insulated 200Amp. vacuum circuit breakers. SF6 insulated Vacuum circuit breakers with self- powered relay having Transformer protection, over current and earth fault protection. M.V Metering arrangement with digital electronic meter, C.T" etc. with breaking capacity 20kA for 3sec. Interconnection between RMU and transformer shall be using suitable Aluminum unarmoredXLPE cable. Incomer / outgoing Load break switches shall be suitable for termination of 3C X 300 Sq.mm aluminum armored XLPE Cable. (2)Transformer: 500KVA11KV/400V DYn11 Oil filled hermatically sealed transformerwith corrugated wall,without conservator type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/50 Deg cel. Losses and Impedance as per IS-1180:2014 Energy Efficiency Level-02(3) LV Switchgear : Incoming 800Amps 400V 36KA 4P Fixed Manual Air Circuit Breaker with numerical overcurrent and earthfault protection LV Switchgear : Outgoing Eight nos. Four Pole 100Amp, 400V MCCBsIncluding 3phase 4 wire energy meter(4)Enclosure: Outdoor type enclosure having modular construction of Galvanized Sheet Steel. The degree of protection for HT & LT switchgear compartment shall be IP54 & degree of protection of transformer compartment of the enclosure shall be minimum IP23. The enclosure exterior shall be painted with polyurethene paint / powder coated and tropicalized to Indian weather conditions. Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door-operated switch shall be provided for each compartment. Structure of the substation shall be able to withstand the gross weight of all equipment. It should be possible to transport the equipment along with transformer, RMU & LT Panel from one site to another.
7Distribution Transformer: Supply, Installation, Testing, & Commissioning of315kV, 3 Phase, 11/0.433kV, 50Hz oil immersed outdoor type Distribution Transformer DYN11, off-load tap changer of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/50 Deg cel. Losses and Impedance as per IS-1180:2014 Energy Efficiency Level-02, with all necessary fittings and accessories on existingstructure complete as required.
8Pipe Earthing :Supply & Erection of "KAPITRODE" centrifugally cast Iron Pipe earthing electrode 50mm dia, (NB 57ODx2.9mtr length,x3.5mmthickness, Wt-12Kg) with(HDG) clamp (32x6mm) and funnel perforated holes and taper end GI Nut & Bolts single long bolts for centre cut as per IS3043 with supply of ECC back fill compound(50kg),Earthing test link IP65 Polycarbonate GI Busbar(32x6mm with nut & bolts), GI HDG Strips with PVC HS Sleaves as required.
9Earth Strip: Supply and Erection of GI Flat strip 50mm x 6 mm thick from earth electrode directly in ground and surface fixed with GI stapples of same size.
10EMI Antenna based portable On Line PD Monitoring Device(make Prysmian/ DIAEL/Qualitrol)
1133KV UNDER GROUND CABLING SYSTEM :
12Preparation of Cable Trench by HDD Method_Boring and Supply & laying of 160mm dia HDPE pipe direct into the earth of 2500mm depth below the ground surface without effecting the existing road bydigging/drilling horizontally or diagonically direction for road crossing /water supply line/Telecommunication line/Gas Pipe line etc. including excavation earthfor entry pit including Supply, laying ,drawing & commissioning 33kV, 3CX400 Sqmm., TR-XLPE (E) Aluminiumconductor armoured cables suitable for working voltage upto 33000Volts through the pipe as per direction of engineer in charge.
13Preparation of Cable Trench by Manual Method_Boring and Supply & laying of 150mm dia GI pipe direct into the earth of minimum 1200mm depth below the ground surface without effecting the existing road bymanual digging/drilling horizontally or diagonically direction for road crossing /water supply line/Telecommunication line/Gas Pipe line etc. including excavation earthfor entry pit including Supply, laying ,drawing & commissioning 33kV, 3CX400 Sqmm., TR-XLPE (E) Aluminiumconductor armoured cables suitable for working voltage upto 33000Volts through the pipe as per direction of engineer in charge.
14Open Trenches Method:Supply , Laying & Commissioningof one number PVC insulated and PVC sheathedXLPE power cable of 33 KV grade, 400sqmmdirect in ground including excavation of earth for cable trenches, sand cushioning, protective covering and refilling the trench etc as required. (Trench Size: Width-350mm, Hieght-1200mmSand(couhioning): Hieght-250mm, Width-350mm/ Protection: Double layer Bricks)including coiling of excess cable at a depth of minimum 1200 with double layer bricks protection.
15Cable Section Riser:Supply , Laying & Commissioning of one number400sqmm, PVC insulated and PVC sheathed / XLPE power cable of 33 KV grade of all size in theGI Pipe/HDPE for riser including tieup of Pipe with pole by the help MS Flat Clamp (excluding cost of Clamp and Nut&Bolts) and including coiling of excess cable at a depth of minimum 1200 with double layer bricks protection as per direction of Eng-In Charge.
16Supply , Laying & Commissioningof Laying & drawing of one number400sqmm, PVC insulated and PVC sheathed , XLPE power cable of 33 KV grade in the existing RCC/ HUME/ METAL pipe as required.
17Cable Termination _ Outdoor Type:Supplying and Making Outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable3 core,400sqmm, XLPE aluminium conductor cable of 33 KV grade as required.
18Straght Through Jointing Kits:Supplying and making tapex type straight through cable jointing complete with all accessories including ferrules suitable for following size of 3 core, 400sqmm, XLPE aluminium conductor cable of 33 KV grade as required.
19Cable Identification Marker: Providing of Pre-cast cement concrete cableidentification route marker (1 cement: 2sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1: 3( 1 cement : 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits as per design, drawing and specification of TSECL. The marker shall be embossed "DANGERS: TSECL, 33KV POWER CABLE" with Black colour letter(both side). The visible part shall be painted with Yellow colour japan paint.
2011kV UNDER GROUND DISTRIBUTION SYSTEM
21Preparation of Cable Trench by HDD Method_Boring and Supply & laying of 110mm dia HDPE pipe direct into the earth of 2500mm depth below the ground surface without effecting the existing road bydigging/drilling horizontally or diagonically direction for road crossing /water supply line/Telecommunication line/Gas Pipe line etc. including excavation earthfor entry pit including Supply, laying ,drawing & commissioning 11kV, 3CX240 Sqmm., TR-XLPE (E) Aluminiumconductor armoured cables suitable for working voltage upto 11000Volts through the pipe as per direction of engineer in charge.
22Preparation of Cable Trench by HDD Method_Boring and Supply & laying of 110mm dia HDPE pipe direct into the earth of 2500mm depth below the ground surface without effecting the existing road bydigging/drilling horizontally or diagonically direction for road crossing /water supply line/Telecommunication line/Gas Pipe line etc. including excavation earthfor entry pit including Supply, laying ,drawing & commissioning 11kV, 3CX120 Sqmm., TR-XLPE (E) Aluminiumconductor armoured cables suitable for working voltage upto 11000Volts through the pipe as per direction of engineer in charge.
23Preparation of Cable Trench by Manual Method_Boring and Supply & laying of 100mm dia GI pipe direct into the earth of minimum 1200mm depth below the ground surface without effecting the existing road bymanual digging/drilling horizontally or diagonically direction for road crossing /water supply line/Telecommunication line/Gas Pipe line etc. including excavation earthfor entry pit including Supply, laying ,drawing & commissioning 11kV, 3CX240 Sqmm., TR-XLPE (E) Aluminiumconductor armoured cables suitable for working voltage upto 11000Volts through the pipe as per direction of engineer in charge.
24Preparation of Cable Trench by Manual Method_Boring and Supply & laying of 100mm dia GI pipe direct into the earth of minimum 1200mm depth below the ground surface without effecting the existing road bymanual digging/drilling horizontally or diagonically direction for road crossing /water supply line/Telecommunication line/Gas Pipe line etc. including excavation earthfor entry pit including Supply, laying ,drawing & commissioning 11kV, 3CX120 Sqmm., TR-XLPE (E) Aluminiumconductor armoured cables suitable for working voltage upto 11000Volts through the pipe as per direction of engineer in charge.
25Open Trenches Method:Supply, Laying and commissioning of3-Core, 240sqmm PVC insulated and PVC sheathed TR- XLPE power cable of 11 KV grade of size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Trench Size: Width-350mm, Hieght-1200mm Sand(couhioning): Hieght-250mm, Width-350mm/ Protection: Double layer Bricks as per direction of Engineering incharge.
26Supply, Laying & commissioning of 11kV, 3CX240 Sqmm., TR-XLPE (E) Aluminiumconductor armoured cables suitable for working voltage upto 11000VoltsIn Existing Pipe/Duct/Hume Pipe/Trenches in an approved manner complete as required as per direction of Eng. In-Charge.
27Open Trenches Method:Supply, Laying and commissioning of3-Core, 120sqmm PVC insulated and PVC sheathed TR- XLPE power cable of 11 KV grade of size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Trench Size: Width-350mm, Hieght-1200mm Sand(couhioning): Hieght-250mm, Width-350mm/ Protection: Double layer Bricks as per direction of Engineering incharge.
28Supply, Laying & commissioning of 11kV, 3CX120 Sqmm., TR-XLPE (E) Aluminiumconductor armoured cables suitable for working voltage upto 11000VoltsIn Existing Pipe/Duct/Hume Pipe/Trenches in an approved manner complete as required as per direction of Eng. In-Charge.
29Cable Termination _ Indoor Type: Supply ,Erection and commissioning of 3CX240 Sqmm. heat shrinkable type indoor termination along with necessary accessories to accommodate of 11kV TR-XLPE(E) aluminium cable complete with all kit contents including earth continuity connection along with 3 nos. crimpling type aluminium lugs / thimbles of suitable capacity including making joints etc. in an approved manner complete as required and as per specifications.
30Cable Termination _ Indoor Type: Supply ,Erection and commissioning of 3CX120 Sqmm. heat shrinkable type indoor termination along with necessary accessories to accommodate of 11kV TR-XLPE(E) aluminium cable complete with all kit contents including earth continuity connection along with 3 nos. crimpling type aluminium lugs / thimbles of suitable capacity including making joints etc. in an approved manner complete as required and as per specifications.
31Cable Termination _ Outdoor Type: Supply ,Erection and commissioning of 3CX240 Sqmm. heat shrinkable type indoor termination along with necessary accessories to accommodate of 11kV TR-XLPE(E) aluminium cable complete with all kit contents including earth continuity connection along with 3 nos. crimpling type aluminium lugs / thimbles of suitable capacity including making joints etc. in an approved manner complete as required and as per specifications.
32Cable Termination _ Outdoor Type: Supply ,Erection and commissioning of 3CX120 Sqmm. heat shrinkable type outdoor termination along with necessary accessories to accommodate of 11kV TR-XLPE(E) aluminium cable complete with all kit contents including earth continuity connection along with 3 nos. crimpling type aluminium lugs / thimbles of suitable capacity including making joints etc. in an approved manner complete as required and as per specifications.
33Straight Through Joints: Supply ,Erection and commissioning of 3CX240 Sqmm. heat shrinkable typeStraight through jointsto accommodate of 11kV TR-XLPE(E) aluminium cable complete with all kit contents including earth continuity connection along with 3 nos. crimpling type aluminium lugs / thimbles of suitable capacity including making joints etc.in an approved manner complete as required and as per specifications.
34Cable Identification Marker: Providing of Pre-cast cement concrete cableidentification route marker (1 cement: 2sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1: 3( 1 cement : 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits as per design, drawing and specification of TSECL. The marker shall be embossed "DANGERS: TSECL, 11KV POWER CABLE" with Black colour letter(both side). The visible part shall be painted with Yellow colour japan paint.
35Design, Engineering, manufacturing, Supply & Erection ofSteel Tubular Pole, 9.0mtr. Long (Designation 410: SP-32) (hot dip galvanized ) conforming to ISS: 2713(P-I & II)/1980 as amended up-to-date and other relevant IS with up-to-date amendmentswith base plate and as per technical specification of bid document.
36Supply and Erection of fabricated 1.20Mtr long cross-armmadeof 70 X 40 X 40 X 6 mm. Galvanised channelduly galvanised as per relevant I.S. on Steel Tubular Pole with supply of clamp (made of 50x6 mm. GI flat Flat duly galvanised as per relevant I.S), nuts and bolts as requiredas per direction of Eng-In-Charge.
37Supply and Erection of fabricated 0.30Mtr long cross-armmadeof 70 X 40 X 40 X 6 mm. Galvanised channelduly galvanised as per relevant I.S. on Steel Tubular Pole with supply of clamp (made of 50x6 mm. GI flat Flat duly galvanised as per relevant I.S), nuts and bolts as requiredas per direction of Eng-In-Charge.
38Supply and Erection of fabricated 2.50Mtr long cross-armmadeof 75 X 40X40 X 6 mm. Galvanised Angleduly galvanised as per relevant I.S. on Steel Tubular Pole with supply of clamp (made of 50x6 mm. GI flat Flat duly galvanised as per relevant I.S), nuts and bolts as requiredas per direction of Eng-In-Charge.
39Supply and Erection of 11KV Polymeric Pin insulator
40Supply, laying, binding of ACSR DOG Conduction for Cable section bus and bus to GOS as per diection of Engineering In-Charge.
41Design, Engineering, manufacturing, handling, transportation, insurance and supply of outdoor type Triple pole (3 phase), 12 KV, 600 Amp. Manually gang operated, air brake switch, 3 post vertical type shall confirming IS: 9920/1981 (part-I to IV), IS: 2633 & IS: 2544/1973 with latest amendment if any
42LT UNDER GROUND DISTRIBUTION SYSTEM & OTHERs WORK
43LV Distribution Box(Metering Pannael) : Supply, Erection, Testing, Commossioning of L.T Distribution Box for distribution LT Circuit with the switchgears and otehr necessary accessories and inbuilt padlocking facility, etc. required to complete the job as per specification and detailed technical parameters. The Feeder boxes shall be 1nos 630Ammps MCCB for inconing and 3Nos 400Amp MCCB for outgoing, Phase indication Lamp(R/Y/B, Indication Lamp for MCCB (ON/OF ), 3-Phase digital Ammeter, 3-Phase Digital Volt meter,Ammeter selector switch, Volt meter selector Switch, CTR-600/1A, Class-1,VA-5, 6A TPN MCB,10kA. The enclusere shall be made ofsmooth finished cold rolled sheet steel of thickness not less than 3.15 mm
44LV Distribution Box(Feeder Pillar): Supply, Erection, Testing, Commossioning of L.T Distribution Box (Feeder Pillar) for the providing service connection with the switchgears and otehr necessary accessories and inbuilt padlocking facility, etc. required to complete the job as per specification and detailed technical parameters. The Feeder boxes shall be 2nos 400Ammps MCCB for inconing and 3Nos 160Amp MCCB for outgoing, Phase indication Lamp(R/Y/B). The enclusere shall be made ofsmooth finished cold rolled sheet steel of thickness not less than 3.15 mm
45LV Distribution Box(Feeder Pillar): Supply, Erection, Testing, Commossioning of L.T Distribution Box (Feeder Pillar) for the providing service connection with the switchgears and otehr necessary accessories and inbuilt padlocking facility, etc. required to complete the job as per specification and detailed technical parameters. The Feeder boxes shall be 2nos 400Ammps MCCB for inconing and 3Nos 160Amp MCCB for outgoing, Phase indication Lamp(R/Y/B). The enclusere shall be made ofsmooth finished cold rolled sheet steel of thickness not less than 3.15 mm
46Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil dressing of sides and ramming of bottoms with and disposal of surplus excavated soil as directed within a lead of 50 metres. Trench Size: Width-350mm, Hieght-1200mm.
47Filling available excavated earth (excluding rock) in trenches, sides of foundations etc. in layers not exceeding 20cm m depth, consolidating each deposited layer by ramming and watering, lead up to 50 metres. Trench Size: Width-350mm, Hieght-1200mm.
48Supply & Laying of 110mm Outer DiaHDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part- II complete with fitting and cutting, jointing etc. in the existing trench, complete as required
49Supply & Laying of 75mm Outer DiaHDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part- II complete with fitting and cutting, jointing etc. in the existing trench, complete as required
50Supply, Laying & Commissioning of one number PVC insulated and PVC sheathed XLPE power cable of 1.1 KV grade, 2core, 10 sqmm in the existing RCC/ HUME/ METAL/HDPE pipe as required.
51Supply, Laying & Commissioning of one number PVC insulated and PVC sheathed XLPE power cable of 1.1 KV grade, 4core, 25sqmm in the existing RCC/ HUME/ METAL/HDPE pipe as required.
52Supply, Laying & Commissioning of one number PVC insulated and PVC sheathed XLPE power cable of 1.1 KV grade, 4core, 35sqmm in the existing RCC/ HUME/ METAL/HDPE pipe as required.
53Supply, Laying & Commissioning of one number PVC insulated and PVC sheathed XLPE power cable of 1.1 KV grade, 4core, 50sqmm in the existing RCC/ HUME/ METAL/HDPE pipe as required.
54Supply, Laying & Commissioning of one number PVC insulated and PVC sheathed XLPE power cable of 1.1 KV grade, 4core, 240sqmm in the existing RCC/ HUME/ METAL/HDPE pipe as required.
55Supply, Laying,commissioning and fixing of one number PVC insulated and PVC sheathed XLPE power cable of 1.1 KV grade,4Core, 50sqmmon wall surface clamped with 1mm thicksaddleas required
56Supply, Laying,commissioning and fixing of one number PVC insulated and PVC sheathed XLPE power cable of 1.1 KV grade,4Core, 35sqmmon wall surface clamped with 1mm thicksaddleas required
57Supply, Laying,commissioning and fixing of one number PVC insulated and PVC sheathed XLPE power cable of 1.1 KV grade,4Core, 25sqmmon wall surface clamped with 1mm thicksaddleas required
58Supply, Laying,commissioning and fixing of one number PVC insulated and PVC sheathedXLPE power cable of 1.1 KV grade, 2Core, 10sqmmon wall surface clamped with 1mm thicksaddleas required
59LV CABLES _ End Termination : Supply and Erection of Indoor/Putdoor Termination kits comprising of double brass compression gland and aluminium lugs. for 240sqmm, 4core, 1100 V grade XLPE insulated PVC sheathed aluminium wire wound armouring for single core and galvanized steel strip wound armoured for multicore "Aluminium conductor" power cable of the following sizes as per enclosed detailed specifications and relevent IS .
60LV CABLES _ End Termination : Supply and Erection of Indoor/Putdoor Termination kits comprising of double brass compression gland and aluminium lugs. for 25-50sqmm, 4core, 1100 V grade XLPE insulated PVC sheathed aluminium wire wound armouring for single core and galvanized steel strip wound armoured for multicore "Aluminium conductor" power cable of the following sizes as per enclosed detailed specifications and relevent IS .
61Supplying, Installation, testing and commissioning of 11KV, 3-Phase, 4Way, OUTDOOR TYPE, compartmentalized, double door Feeder Pillars fabricated out of suitable size angle iron and flats and covered with 2mm thick cold rolled CRCA sheet, weather proof powder coated painting etc., complete with 630Amp Al. Bus Bar, name plate and pad locking facility etc. complete as required.
62Supply, Erection, testing & commissioning of 11 KV, 800 Ampscontinuos ratedcurrent, 350 MVA rupturing capacityIndoor Vaccum Circuit Breaker( for outgoing feeder) , complete with 1 set of CT of ratio300/1-1, Control & Relay Pannel Simplex type with 110 Volt DC actuated electrical closing/tripping mechanism and internal wiring, 2-Over current & 1-earth fault combined Micom digital relay,1 no.electromechanical AREVA Master Trip Relay, auxiliary relays as required,1 no.L&T / SECURE make "Tri- Vector" Meter(SCADA compatible), 3- Ammeter, 1 -Voltmeter,1 -C.T operated static KW meter ,with panel bus mounted C.T and integral earthing facility includinginernal arc tested panelConforming to relevant ISS/IECas reqd.including standard indication facilitiesas per requirement detailed in bid document. The pannel should be matched with existing pannel.
63Cable Identification Marker: Providing of Pre-cast cement concrete cableidentification route marker (1 cement: 2sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1: 3( 1 cement : 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits as per design, drawing and specification of TSECL. The marker shall be embossed "DANGERS: TSECL, 11KV POWER CABLE" with Black colour letter(both side). The visible part shall be painted with Yellow colour japan paint.
64Pipe Earthing :Erection of Earthing with G.I. earth pipe including supply of 2.5 metre long, 40 mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required.
65Earth Strip: Supply and Erection of GI Flat strip 50mm x 6 mm thick from earth electrode directly in ground and surface fixed with GI stapples of same size.
6633KV OUT DOOR BAY ATCOLLEGETILLA& RAMPUR SUB-STATION.
67Design, Engineering, manufacturing, supply, Installation, testing & commissioning of 10KA, 30 KV, Station Valve type metal oxide heavy duty Lightning Surge Arrestor suitable for operation on 33KV Sytem conformingto ISI : 3070 (P-1) / 1974 and amendments thereafter and as required and technical specification in the BID document.
68Design, Engineering, manufacturing, Supply, Installation, testing & commissioning of 36kV, 630A, 25kA for 3 seconds, 3-ph double break center rotating type (DBCR), Gang Operated,isolator along with Support Insulators, Operating Mechanism, Base Channel down Pipe and all required accessories complete as per technical specifications, scope of works and approved drawings a) With earth switch.
69Design, Engineering, manufacturing, supply, Installation, testing & commissioning of 33 KV, 1250A, 750 MVA rupturing capacity, outdoor Vacuum Circuit Breaker complete with motor operated spring closing (Local / Remote) arrangement with all accessories including lattice support structure,foundation bolts, G.I. nuts & bolts,washers etc. as required and as per relevant ISS complete operative on 110V DC. including Design, Engineering, manufacturing, supply of33 KV control & relay panel, simplex type complete with SCADA compatible Directional O/C and E/F protection, master trip relay, trip circuit supervision relay, AC/DC supervision relay, 1- voltmeter, 3- ammeter, CT operated static trivector meter with DLMS compatible, internal panel wiring, simaphone for Vacuum Circuit breaker & isolator, Mimic bus diagram (Metal size 4mm thick X 10mm width)as required and as per relevant ISS complete operative on 110V DC andas per requirement detailed in bid document.(At Rampur SS & Collegetilla)
70Design, Engineering, manufacturing, insurance, Testing at Ex-works, transportation, loading, unloading, storage, delivery at site& supply ,Installation, testing & commissioning of 1100 Volts grade PVC insulated PVC sheathed, 2.5 sq.mm., 12 Core stranded copper conductor control cable with armouringas per IS:1554(Part-I)1988.
71Design, Engineering, manufacturing, insurance, Testing at Ex-works, transportation, loading, unloading, storage, delivery at site& supply, Installation, testing & commissioning of1100 Volts grade PVC insulated PVC sheathed, 2.5 sq.mm., 2 Core stranded copper conductor control cable with armouringas per IS:1554(Part-I)1988.
72Design, Engineering, manufacturing, insurance, Testing at Ex-works, transportation, loading, unloading, storage, delivery at site& supply, Installation, testing & commissioning of1100 Volts grade PVC insulated PVC sheathed, 2.5 sq.mm., 4 Core stranded copper conductor control cable with armouringas per IS:1554(Part-I)1988.
73Design, Engineering, manufacturing, insurance, Testing at Ex-works, transportation, loading, unloading, storage, delivery at site& supply , Installation, testing & commissioning of 1100 Volts grade PVC insulated PVC sheathed, 2.5 sq.mm., 7 Core stranded copper conductor control cable with armouringas per IS:1554(Part-I)1988.
74Earthing with G. I pipe 3mtr. Long and 40mm dia, including excavation of earth pit with supply andalternate layer of salt(100Kg/pit) & Charcoal(80kg/pit) as per approved drawing and neccessary requirednuts &bolts, washer etc including supply of40 mm. dia. 3 mtr. long perforated hot dip G.I. pipe.
75Supply & Laying of G. I. flat of size 50 X 6 mm. for Sub-station earthing grounding mat complete including connection with different equipments and structure as per relevant ISSand othersnecessary for formation ofmat as required.
76CIVIL WORKS: Foundation work for RMU:
77Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth upto 50 m and lift upto 1.5 m, disposed soil to be levelled and neatly dressed:-All kinds of soil
78Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kind of soil.
79Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete.
80Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.-All kinds of soil
81Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:i)1 : 3 : 6 ( 1 cement : 3 fine sand : 6 graded stoneaggregate of 40 mm nominal size)
82Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. i) Thermo-Mechanically Treated bars of grade Fe-500D or more.
83Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level: i) 1:1.5:3( 1 Cement: 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size)
84Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concret work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size).
85Centering shuttering including struttings, propping etc. and removal of form work for: i) Foundations, footings, bases for columns etc. for mass concrete with timber plank
86First class brick work in foundation and plinth including cost of all materials as required complete:- In cement mortar 1:4 ( 1 cement : 4 fine sand ).
8712 mm cement plaster in single layer including cost of materials required and finishing even and smooth and curing complete.In cement mortar 1 : 4 ( 1 cement : 4 fine sand )
88Neat cement punning.
89Civil Work: Foundation for Compaq Sub-Station(CSS) :
90Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. -All kinds of soil
91Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete
92Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. -All kinds of soil
93Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level:(i)1 : 4 : 8 ( 1 cement : 4 fine sand : 8 graded stoneaggregate of 40 mm nominal size)
94Reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding all complete upto floor five level. i)Mild steel and Medium\Tensile steel bars.
95Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- -All work upto plinth level: 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
96Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishingand reinforcement:- 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
97Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement- 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
98Centering shuttering including struttings, propping etc. and removal of form work for: (i) Foundations, footings, bases for columns. . for mass concrete with timber plank (ii) Columns, piers, abutments, pillaras, posts and struts.(iii) Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply (iv) Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply
9912 mm cement plaster of mix i)Cement mortar 1:6 ( 1 cement : 6 fine sand )
100Neat cement punning.
101Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. complete as required:-i) In stringers, treads, landing etc. of stair cases including use of chequered plate wherever required, all complete.
102Providing and fixing paint coated FRP Composite fencing 4mm thick 1.80m height with FRP picket Flat 35x5mm, Hollow Squre section 50x50x3mm embedded in cement concrete block of 150x150x200mm of 1:3:6 ( 1 cement : 3 fine sand : 6 stone aggregate of 20mm size) in/c 50x25x3mm sub frame section, 12mm FRP round rail , hings Door stopper, name plate etc complete as per direction of Engineer-in-charge.
103Providing and fixing ISI marked oxidised M.S.sliding door bolts with nuts and screws etc. complete i) 300x16mm
104Painting with synthetic enamel paint, having VOC (Volatile Organic Compound) content less than 150 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. [Payment shall be made after submission of Test Certificate issued by the Manufacturer] i) two coats
105Finishing walls with water proofing cement paint of required shade of approved brand and manufacture on new work ( two or more coats applied @ 3.84 kg/10 sqm) complete. [Payment shall be made after submission of Test Certificate issued by the Manufacturer) New work ( two or more coats applied @ 3.84 kg/10 sqm)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy